ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER CONDITIONS OF USE

Size: px
Start display at page:

Download "ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER CONDITIONS OF USE"

Transcription

1 ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER AWHP -II/E.: from to kw with additional heating by integrated electrical resistance AWHP -II/H: from to kw with additional hydraulic heating by boiler (or without additional heating) ALEZIO AWHP MR-II ALEZIO AWHP 8 MR-II ALEZIO AWHP to TR/MR-II Heating by radiators, underfloor heating/cooling or air conditioning by fan-convectors. Management of DHW Heat pump air/water Electricity (energy supplied to the compressor) Natural renewable energy free of charge ALEZIO heat pumps stand out because of their performance: COP of. to. for an outside temperature of + C (EER of. to. for an outside temperature of + C). High tech products with an INVERTER compressor and power receiver, ALEZIO heat pumps offer improved set temperature stability, a significant reduction in electricity consumption and silent running. Thanks to their reversibility and the option of producing a cooling effect (underfloor cooling type, water at +8 C) or air-conditioning (by fan-convectors, water at + C), ALEZIO heat pumps offer absolute comfort at all times of year. With their compact construction, modern design and simple installation, they can be easily incorporated into a new build or existing environment. CONDITIONS OF USE Limit operating temperatures - in heating mode: Outside air: - /+ C Water: + 8/+ C - in cooling mode: Outside air: + /+ 0 C Water: + /+ C Maximum operating pressure: bar EASYLIFE

2 PRESENTATION OF ALEZIO - HEAT PUMPS INTRODUCTION ALEZIO heat pumps are of the Split Inverter type. Thanks to its integrated control system, the inverter system with Power receiver can be used to adapt the output of the heat pump perfectly to the needs of the installation. Thus, when needs are high in winter, the heat pump can provide its nominal output and, when needs are lower, the heat pump can provide only 0% of its nominal output. With the inverter system with Power receiver, electricity consumption is controlled and the COP improved. The connection between the outdoor unit and the indoor module is made by the refrigeration piping containing refrigerant. INVERTER TECHNOLOGY WITH POWER RECEIVER This technology offers: - Optimal operation at low outside temperatures, up to - C, by accepting a high condensation temperature whilst preventing excessive overheating on compressor discharge. - Maintenance of heating output with a high mass flow rate thanks to the use of a second expansion valve to control excessive cooling and to improve calorific recycling at lower evaporation temperatures. Double expansion and power receiver -way valve Principle diagram of heat pumps Evaporator Outdoor unit Compressor Expansion valve - An increase in operating time in heating mode and a reduction of short cycles thanks to the inverter system which is used to adapt compressor output (from 0% to 00%) to the needs of the installation and control electricity consumption. - Reduction of the defrosting time by a control system and a large surface area on the outdoor exchanger. - A faster rise in temperature in the refrigerant fluid, preventing any risk of liquid surge at the compressor intake thanks to the Power receiver. Pressure P (MPa) Refrigeration cycle Heating output Refrigerant piping Indoor module Condensor PAC_F00A Compressor Power receiver "Additional" sub-cooling Expansion A Expansion B Outdoor unit THE VARIOUS MODELS AVAILABLE Heating by radiators or underfloor heating/cooling PAC_Q00 Reversible air/water heat pump for outside temperatures up to - C Back-up type Output Electrical by resistance Hydraulic by boiler Heating Cooling single phase three phase (or without back-up) kw () kw () AWHP MR-II/EM AWHP MR-II/H.0. AWHP 8 MR-II/EM AWHP 8 MR-II/H 8.. AWHP MR-II/H AWHP MR-II/EM AWHP TR-II/ET 0.8. AWHP TR-II/H AWHP MR-II/H AWHP MR-II/EM AWHP TR-II/ET.0. AWHP TR-II/H AWHP MR-II/H AWHP MR-II/EM AWHP TR-II/ET..8 AWHP TR-II/H Back-up type Output Air conditioning by fan-convectors Electrical by resistance Hydraulic by boiler Heating Cooling single phase three phase (or without back-up) kw () kw () AWHP MR-II/EMI AWHP MR-II/HI.0. Reversible air/water AWHP 8 MR-II/EMI AWHP 8 MR-II/HI 8.. heat pump for outside AWHP MR-II/HI AWHP MR-II/EMI AWHP TR-II/ETI 0.8. temperatures up to AWHP TR-II/HI - C AWHP MR-II/HI AWHP MR-II/EMI AWHP TR-II/ETI.0. AWHP TR-II/HI AWHP MR-II/HI AWHP MR-II/EMI AWHP TR-II/ETI..8 AWHP TR-II/HI () Water flue temp.: + C outside temp.: + C. () Water flue temp.: + 8 C, outside temp.: + C PAC_Q00 Indoor module MIV Additional quantity of heat recovered Free energy Work of the compressor Enthalpy (kj/kg) PAC_F0

3 TECHNICAL CHARACTERISTICS OF THE TECHNICAL SPECIFICATIONS Conditions of use: Use limit temp. in heating mode: Water: + 8 C/+ C Outside air: - C/+ C Use limit temp. in cooling mode: Water: + C/+ C Outside air: + C/+ 0 C Max. operating pressure: bar Model AWHP- MR-II 8 MR-II MR-II TR-II MR-II TR-II MR-II TR-II Heating output () kw Heating COP () Absorbed electrical power () kwe Nominal amperage () A Cooling output () kw Cooling COP (EER) () Absorbed electrical power () kwe Nominal water flow rate at t = K m /h Manometric height available at nominal flow rate mbar Nominal air flow rate m /h Power supply voltage outdoor unit V 0 V~ 0 V~ 0 V~ 00 V~ 0 V~ 00 V~ 0 V~ 00 V~ Start-up intensity A Sound output () db(a) Sound pressure () db(a) 0 0 R 0 A refrigerant kg.. Refrigerant pipe size (liquid-gas) pouce /-/ /8-/8 /8-/8 /8-/8 /8-/8 /8-/8 /8-/8 /8-/8 Max. preloaded piping length m Weight empty outdoor unit kg 0 0 Weight empty indoor MIV-II module kg () Heating mode: outside air temp. + C, water flue temp. + C. () Cooling mode: outside air temp. + C, water flue temp. +8 C. Performance according to with EN -. () m from the appliance, free field. () Test performed according to the standard NF EN 0 Heating output and COP for levels of water flue temperature depending on the outside temperature Water flue temperature Coefficient of performance COP R0A Water flue temperature Heating output in kw 8 0 MR/TR 8 MR/TR MR/TR 8 MR 0 8 MR Outside air temperature in C 8 MR Outside air temperature in C MR/TR MR/TR MR MR/TR MR/TR MR MR/TR MR/TR Cooling output and EER (cooling COP) for level of water flue temperature depending on the outside temperature Cooling output in kw Water flue temperature Energy efficiency rate EER (cooling COP) Water flue temperature MR/TR MR/TR Outside air temperature in C MR/TR 8 MR MR Outside air temperature in C MR/TR MR/TR 8 MR MR MR/TR PAC_F0A

4 TECHNICAL CHARACTERISTICS OF THE ALEZIO heat pumps comprise an outdoor unit and an indoor MIV-II module (InVerter Module). CHARACTERISTICS OF THE INDOOR MIV-II MODULE It incorporates all hydraulic and control components, facilitating installation, and is simple to use. The MIV is available in versions: versions for heating by radiators or underfloor heating/cooling: MIV-II/EM: for additional heating via integrated electrical to kw single phase resistance; MIV-II/ET: for additional heating via integrated electrical to kw three phase resistance; MIV-II/H: for hydraulic back-up by boiler (or without back-up). versions for air-conditioning by fan-convectors: MIV-II/EMI: for additional heating via integrated electrical to kw single phase resistance; MIV-II/ETI: for additional heating via integrated electrical to kw three phase resistance; MIV-II/HI: for hydraulic back-up by boiler (or without back-up). MIV-II/H and E 00 MIV-II/EI: with mounting frame EH MIV-II/HI: with mounting frame EH Model shown: MIV-II/HI 0 PAC_F0 Model shown: MIV-II/H, PAC_F0B Heating return Ø G Heating flow Ø G Boiler flow connection Ø G (MIV-II/H and HI only) Boiler return connection Ø G (MIV-II/H and HI only) Gas refrigeration connection AWHP- MR-II: /" flare AWHP-8 to MR/TR-II: /8" flare MIV-II: /8" flare Liquid refrigeration connection AWHP- MR-II: /" flare AWHP-8 to MR/TR-II: /8" flare MIV-II: /8" flare Components MIV-II/EM and MIV-II/ET MIV-II/H MIV-II/EI 0-litre expansion vessel Automatic air vent Interface board Safety valve bar Stainless steel plate heat exchanger Flowmeter Heating pump speeds Decoupling cylinder Electrical resistance: to kw for MIV-II/EM to kw for MIV-II/ET Connections to boiler PAC_Q0 Refrigeration connections with outdoor unit PAC_Q0 PAC_F08A Model shown: MIV-II/E with front panel removed and control panel titled Model shown: MIV-II//H with front panel removed and control panel titled Model shown: MIV-II/EI preequipped for air-conditioning by fanconvectors (delivered with mounting frame)

5 TECHNICAL CHARACTERISTICS OF THE TECHNICAL CHARACTERISTICS OF THE OUTDOOR UNIT Main dimensions (mm and inches) AWHP MR-II AWHP to MR/TR-II AWHP 8 MR-II 햶 Gas refrigeration connection: - AWHP- MR-II: / flare - AWHP-8 to MR/TR-II: /8 flare PAC_F0088A 0 0 PAC_F00 PAC_F008A 00 햷 Liquid refrigeration connection: - AWHP- MR-II: / flare - AWHP-8 to MR/TR-II: /8 flare Components AWHP 8 MR-II AWHP to MR/TR-II Evaporator Electronic PCB -way valve for cycle inversion Stop valve on the refrigeration connections with outdoor unit Power receiver PAC_Q008 PAC_Q00 Inverter compressor AWHP MR-II Evaporator Electronic PCB Inverter Compressor PAC_Q0 Ventilator

6 THE CONTROL PANEL FITTED TO THE MIV-II/ The control panel fitted to the MIV-II module on ALEZIO heat pumps incorporates an electronic control system used to adapt heating output to the actual needs of the installation according to the outside temperature (sensor provided). To do this, the control system activates modulation of the compressor (via the BUS cable connecting the outside unit to the MIV-II) and, where applicable, manages back-up by the boiler (MIV-II/H) or by the electrical resistance (MIV-II/E). It is used to manage a single direct circuit, which can be a radiator circuit or a low temperature underfloor heating circuit indeed a circuit with fan-convectors and the production of domestic hot water. Moreover, this control system manages the reversibility of the heating in winter/cooling or air-conditioning in summer, and incorporates a power cut-off function and a help mode. To operate in cooling or air-conditioning mode, a wire-controlled or radiocontrolled room temperature thermostat must be connected. THE CONTROL PANEL Large LCD display On/Off switch Menu key Manometer Sweep key Space or reset key Heating temp. adjustment key or key MCR_Q000 Maintenance key or validation key DHW temp. adjustment key or + key CONTROL PANEL OPTIONS Package AD 0 Package AD Q00 8Q0A Programmable wire room thermostat - Package AD Programmable wireless room thermostat - Package AD 00 Non-programmable room thermostat - Package AD 0 The programmable thermostats handle heating control and weekly programming according to various operating modes: Automatic according to the programme, Permanent at a set temperature or Holidays. The wireless version is delivered with a receiver box to be affixed to the wall close to the MIV-II. The non-programmable thermostat can only be used to control the room temperature according to the instruction given. 8Q0 Underfloor heating connection kit - Package HA This cable harness is inserted into the heating pump and includes wiring for connecting a safety thermostat for underfloor heating. EH_Q000 Heating / DHW reversal valve + DHW sensor - Package EH This pack includes a reversal valve with its motor, a DHW sensor, a -pin connector for the DHW sensor and a -pin connector for the reversal valve motor. This valve is used to connect the MIV- II to a DHW tank for the production of domestic hot water (BL for example).

7 OPTIONAL EQUIPMENT FOR THE ALEZIO HEAT PUMP Electrical heater for condensate drain and condensate tray - Package EH This kit is used to prevent condensates freezing. PAC_Q00 PAC_Q00 PAC_Q000A Screen filter 00 μm + gate valve - Package EH This filter is used to protect the water exchanger in the heat pump against impurities. AWHP wall mounting bracket + anti-vibration studs - Package EH This kit is used to mount the outdoor unit of the AWHP to the wall. It comes with anti-vibration studs to limit the transmission of vibrations into the ground. PAC_Q000 Condensate tray tank for wall bracket - Package EH In solid plastic, this kit is used to recuperate condensates from the outdoor unit. It can be fitted to the wall mounting bracket package EH. PAC_Q008 Floor support - Package EH Support in hard wearing PVC, for mounting the outside unit on the ground. The screws, washers and nuts are provided for quick and easy mounting. PAC_Q00 Refrigeration connection kit /8 - /8 length m - Package EH length 0 m - Package EH length 0 m - Package EH Insulated high quality copper pipe to limit heat loss and condensation. Refrigeration connection kit / - / length 0 m - Package EH EH 0 EH 8 8Q0 PAC_Q00 Buffer tank: B 80 T - Package EH 8 / B 0 T - Package EH 0 The 80 and 0 liter tanks are use to limit E.g.: Heat pump output = 0 kw operation of the compressor in short cycles and Min volume in the installation: 0 litres to provide a reserve for the defrosting phase on Dimensions of buffer tanks: reversible Air/Water heat pumps. - B 80 T: H 80 x L 0 x P 0 mm It is also recommended for all heat pumps - B 0 T: H 00 x Ø 0 mm connected to installations in which the water volume is less than l/kw in heating output. EH 8 EH PAC_F088 PAC_F08 Mounting frame: - for MIV-II/EI - Package EH - for MIV-II/HI - Package EH 8 These mounting frames are delivered with isolating valves and enable quick and easy mounting of the MIV-II.

8 OPTIONAL EQUIPMENT FOR THE ALEZIO HEAT PUMP: BL CALORIFIERS MODELS Capacity (litre) Model 0 BL 0 880Q0B Independent DHW calorifiers BL 0 to BL BL 00 PRESENTATION BL independent hot water tanks coupled with a heat pump are used to produce domestic hot water for individual residences. They are made of very thick sheet steel allowing a maximum DHW operating pressure of 0 bar. Their interior is protected by food quality standard high quartz content vitrified enamel and by a magnesium anode. The insulation is made of CFCfree injected polyurethane foam, 0 mm thick. The tanks are fitted with a drainage outlet in the bottom of the tank. H PRINCIPAL DIMENSIONS (in mm and inches) Ø G F E J A B C D E F Ø G H J BL BL BL Domestic hot water outlet G Exchanger inlet G Circulation G / Cold water inlet G Exchanger outlet G D C B A BL BL 0 Drainage G Anode Emplacement DHW sensor G: cylindrical external thread (water tightness by flat gasket) BL_F000 TECHNICAL DATA AND PERFORMANCE Maximum operating temperature: - primary (exchanger): 0 C - secondary (tank): 0 C Maximum operating pressure: - primary (exchanger): bar - secondary (tank): 0 bar Model BL 0 BL 00 BL 00 Calorifi er capacity l Exchange surface m Exchanger capacity l at temp. Primary inlet temp. C outlet Exchanged output kw 0... DHW = C Hourly fl ow at ΔT = K l/h Cooling constant Wh/ h.k.l DHW losses through the outer casing at ΔT= K W 0 88 Net weight kg In order to optimise domestic hot water performance, we recommend combining certain HP outputs with certain tanks.. The recommended combinations are as follows: AWHP MR-II AWHP 8 MR-II AWHP MR-II AWHP MR-II AWHP MR-II BL 0 BL 00 BL 00 Combination recommended Combination not recommended Note: an example of an installation using an ALEZIO HP in combination with a BL type DHW tank can be found on page. OPTIONS FOR BL CALORIFIERS: Anode AM 8Q0 Inert electrical anode with self-adapting current Package AJ 8: for BP/BL 0 to 00 The self-adapting current anode consists essentially of a titanium, platinum-coated rod powered at low voltage. Its advantage over a traditional magnesium anode is that the material is free of wear. Therefore it does not need to be monitored as its life span is practically unlimited. The self-adapting current anode is mounted in the lateral flange, in the place and instead of the magnesium anode; for BP/BL 00 to 00 DHW calorifiers with anodes, the nd anode should also be removed and the opening plugged (kit delivered with the anode). The imposed current anode is delivered with a cable. m long and a transformer which can be plugged into a 0 V socket, to be fitted close to the DHW calorifier. Important: The self-adapting current anode is not compatible with the installation of a shielded electrical resistor.

9 OPTIONS FOR BL CALORIFIERS EG 88 EC 880Q0A 880Q PAC_Q0 Electrical resistors on flange Ø 8 mm (BP/BL 0 to 00) -. kw single, shielded: Package EC 0 -. kw multi-voltage, steatite: Package EC -.0 kw multi-voltage, steatite: Package EG kw multi-voltage, shielded: Package EC These resistors are fitted to a flange in the place and instead of the existing lateral flange. They are equipped with a safety thermostat and are powered independently of the DHW control system on the boiler circuit. NB: When the DHW calorifier is equipped with such a resistor, it is necessary to fit a -bar safety valve to the primary circuit. This valve must be placed between the exchanger and the gate valves in the DHW calorifier. HP/DHW tank hydraulic connection pack - Package EH This pack, comprising ribbed, insulated stainless steel pipes, is used to connect the MIV-II to a DHW tank (length: 0 mm). SIZING A HEAT PUMP INSTALLATION A heat pump must be accurately sized. Indeed, the choice of an appliance with too high an output considerably increases the cost of the installation without providing savings on consumption and the risk of short-cycle operation increases accordingly. The choice Important: Fitting a shielded electrical resistor is not compatible with using a self-adapting current anode. If fitting a steatite resistor, on the other hand, the installation of a self-adapting current anode is essential to guarantee sufficient anti-corrosion protection in the tank. of an appliance with too low an output also leads to excessive energy consumption caused by very long periods of operation of the appliance. It is therefore imperative in the first instance to make an accurate calculation of losses from the home. PROCEDURE FOR CALCULATING LOSSES FROM AN INDIVIDUAL HOME The losses from an individual home can be calculated using the procedure set out in the following Note: this calculation method is given as a rough guide and in formula: no way replaces a thermal survey. De Dietrich s liability may in no D = G x V x ΔT where D = Losses in W V = Habitable volume in m ΔT = Difference between the indoor temperature and the basis outdoor temperature G = Coefficient based on the insulation of the building in W/m. C Example: for an individual home of 0 m (ceiling height. m) with basis outdoor temperature - C constructed after 0, the losses are: D =. x [(0 m x. m) x (0 C - (- C)] = 8 W, i.e.. kw event be invoked. Type of house G in W/m. C Old with no insulation Old with insulation. After 0. After After Very good insulation 0. Bioclimatic 0. SIZING AIR/WATER HEAT PUMPS Air/Water heat pumps alone cannot compensate for the heat loss from a home as their output diminishes when the outside temperature falls and they shut down altogether at the so-called shutdown temperature. This temperature is - C for our AWHP range. Electric or hydraulic boiler back-up is then necessary. The balance point temperature corresponds to the outside temperature at which the output of the heat pump is equal to the heat losses. Tbasis = Basis outside temperature, Teq = Balance point temperature, Tstop = Shutdown temperature For optimum sizing, we recommend observing the following rules: - 0% of heat losses m Heat pump output at To 80% of heat losses where To = Tbasis if Ts Tbasis and To = shutdown if the opposite is the case - heat pump output at Tbasis + Back-up Output = 0% of heat losses Output losses 00% Auxiliary heating only House heat lossesline Auxiliary heating + HP Theoritical output curve of the HP HP only Outputs used Available outputs from the HP Tbasis Tstop T eq Outside temperature in C By following these sizing rules, we obtain, depending on the case, rates of cover ranging from approx. 80% to more than 0%. For more detailed calculations, you can use our DiemaPAC calculation tool available on the Pro page of the website: PAC_F000A

10 SIZING A HEAT PUMP INSTALLATION TABLE FOR SELECTING SINGLE PHASE AWHP MR-II MODELS FROM THE ALEZIO RANGE Heat losses in kw MR + MR + MR + MR + 8 MR + - MR + MR + MR + MR MR + MR + - MR + 8 MR + MR + MR + MR + MR + MR MR + MR MR MR + MR+ MR + MR MR + 8 MR + MR + -8 MR + MR + - MR + MR + -0 MR + MR + MR + - MR + MR + MR+ 8 MR + MR + MR MR + - MR + 8 MR + MR + - MR + MR + 8 MR + MR+ MR MR MR MR+ MR+ 8 MR+ 8 MR MR + 8 MR + 0 MR + MR + MR + MR + MR + MR + MR + 8 MR + 0 MR + MR + MR + MR with Tbasis in C TABLE FOR SELECTING THREE PHASE AWHP TR-II MODELS FROM THE ALEZIO RANGE Heat losses in kw with Tbasis in C TR TR + TR + TR + TR + TR + TR + TR + +..: minimum electrical or hydraulic back-up required in kw with hydraulic back-up only TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + TR + 8 TR + 8 TR + 0 TR + TR + TR + TR + Comments: - the losses must be precisely calculated without oversizing coefficient +, + corresponds to the minimum electrical or hydraulic back-up required in kw, - the electrical back-up is kw max. and requires a three phase power supply ( kw max. in single phase), - in installations with boiler back-up, it is possible to select a slightly undersized single phase heat pump instead of a three phase heat pump, on the understanding that it is tricky with renovation projects to change a single phase into a three phase junction box, - beneath the outside temperature from wich the heat pump stops (- C) only the additional back-ups provide heat. 0

11 INFORMATION REQUIRED FOR INSTALLATION INSTALLING ALEZIO HEAT PUMPS - The outdoor units of ALEZIO heat pumps should be installed close to the house, on a terrace, on the façade or in a garden. They are designed to operate in the rain but can also be installed under cover as long as there is sufficient ventilation. There should be no obstacles to hinder the free circulation of air to the exchanger inlet and outlet (see installation diagrams below). - The emplacement of the outdoor unit should be carefully chosen and protected from prevailing winds in order for it to be compatible with environmental requirements: integration into the site, noise level. We particularly recommend: Not placing the outdoor unit close to sleeping areas Not placing it opposite a glazed wall Avoiding proximity to a terrace Moreover, we recommend positioning the unit above the average depth of snowfall in the region in which it is installed. - It is necessary to provide clearance all around the appliance to carry out connection, commissioning and maintenance operations A Indoor module MIV-II AWHP MR-II 8 MR-II to MR/TR-II A (mm) 00 0 PAC_F00A MINIMUM INSTALLATION DISTANCES TO BE OBSERVED (mm) in red: AWHP /8 MR-II in blue: AWHP to MR/TR-II Max (0) 00 (00) 00 (000) 0 (0) 000 (00) Max (00) 0 (0) 00 (0) 00 (00) 00 (00) 00 (00) 0 (0) 00 (000) PAC_F00 MAXIMUM DISTANCES AND QUANTITY OF REFRIGERANT FLUID TO BE LOADED - Maximum connection distance L between the MIV-II and the HEAT PUMP (in metres) AWHP MR-II 8 MR-II MR/TR-II MR/TR-II MR/TR-II L (m) 0 0 Important: if the refrigeration link between the outdoor unit and the indoor module is less than m long, noise pollution caused by the circulation of the refrigerant fluid may occur. If this is the case, fit a refrigeration link at least m in length by making one or two horizontal connection loops in order to limit noise and oil traps. Additional load of refrigerant fluid for a Model distance > 0 m from from from from to 0 m to 0 m to 0 m to m AWHP MR-II AWHP 8 MR-II AWHP -- MR/TR-II B: 0 m max C: elbows max C B L Outdoor unit Indoor MIV-II module PAC_F008A

12 INFORMATION REQUIRED FOR INSTALLATION REFRIGERATION CONNECTION The commissioning of ALEZIO heat pumps includes operations on the refrigeration circuit. Appliances must be installed, commissioned, maintained and repaired by qualified, authorised personnel, pursuant to the requirements of prevailing directives, laws and regulations and in accordance with the codes of practice of the profession. Refrigeration connection: The refrigeration connection between the outdoor unit and the indoor module is made using cold quality copper piping. The polished, deoxidised, cleaned and dehydrated copper pipe is delivered in bars or coils and its ends are sealed. The copper pipe is insulated with a suitable form of insulation resistant to high temperatures in a thickness appropriate to its diameter. The connections of the refrigeration link to the outdoor unit and the indoor module are done by making dudgeons with flared fittings. If the pipes have to be lengthened, the brazes are done under nitrogen and with silver brazing rods. Diameters, height differences and the length of the refrigeration link between the outdoor unit and the indoor module must comply with the manufacturer s recommendations. Watertightness inspection: When the refrigeration link has been completed, the role of the watertightness inspection is to ensure that there are no leaks and that it will withstand the various operating pressures to which it will be subjected. The watertightness inspection is done with dehydrated nitrogen. The test pressure is bar to start with and is then increased by raising the nitrogen loading in increments of bar until a total pressure of bar is obtained for the R0A. The watertightness test is done using a thousand particle aerosol. ELECTRICAL CONNECTION The electrical installation of heat pumps must be done in accordance with the local and national Codes of Practice and pursuant to prevailing standards, decrees and subsequent texts. Recommended cable cross-sections and circuit breakers to be installed: PAC Type Output electrical absorbed phase Intensity nominal Start-up intensity Max. intensity Evacuation: Evacuation is intended to eradicate air and humidity present in the refrigeration link. Air and humidity have an undesirable effect in the refrigeration circuit as the pressure increases in the system, the absorbed output increases, the efficiency of exchanges diminishes and corrosion of certain components is possible. Evacuation is done with a vacuum pump and a vacuum gauge to ensure the accuracy of the vacuum achieved. The duration of evacuation depends on the cleanliness of the circuit and may take several hours. After evacuation, precautions are taken to prevent the infiltration of humidity into the refrigeration circuit. Loading the refrigerant fluid: Loading a system consists in filling it with a quantity of refrigerant fluid giving the flow rate required for the correct operation of the heat pump. The outdoor units are preloaded in the factory and include a maximum distance for the refrigeration link. If the distance is greater than the maximum distance, it is necessary to add a further load. Annual watertightness inspection (in accordance with the local and national codes and regulations): This inspection is mandatory for all machines containing more than kg of refrigerant fluid in accordance with prevailing regulations. The annual watertightness inspection is mandatory for all ALEZIO heat pumps. Commissioning and maintenance: In order to make the most of the performance of heat pumps and extend their useful life, De Dietrich proposes a commissioning and maintenance service for the ALEZIO range. The cable will be carefully chosen according to the following information: - maximum amperage on the outdoor unit (thermodynamic unit). See the table below, - distance of the appliance from the original power supply, - upstream protection, - neutral operating conditions. Power supply Heat Pump SC: mm Curve D* DJ: Power supply MIV-II SC: mm Curve C DJ: kw A A A AWHP MR-II Single.0.8 x. A x. 0 A x. 8 MR-II Single.0. x A x. 0 A x. MR-II Single.. 8 x A x. 0 A x. TR-II Three.. x. A x. 0 A x. MR-II Single x A x. 0 A x. TR-II Three x. A x. 0 A x. MR-II Single.0. x 0 0 A x. 0 A x. TR-II Three.0 0. x. A x. 0 A x. Electrical back-up MONO:. or kw SC x mm DJ Curve C, A TRI:, or kw SC x. mm DJ Curve C, 0 A SC = cable cross-section in mm DJ = circuit breaker * Motor: Curve D - Differential protection Cable BUS SC: mm

13 INFORMATION REQUIRED FOR INSTALLATION HYDRAULIC CONNECTION The indoor MIV-II module on ALEZIO heat pumps is fully equipped for the connection of a direct circuit (radiators, Available manometric height for the heating circuit at the outlet of the module MIV-II (AWHP /8 MR-II) equiped with the GRUNDFOS UPS -0 pump: underfloor heating or fan-convectors): circulating pump, expansion vessel, heating safety valve, pressure gauge, air vent Available manometric height for the heating circuit at the outlet of the module MIV-II (AWHP // MR-TR-II) equiped with the GRUNDFOS UPS -0 pump: Pressure in mh O 8 III II I 0 0,0 0,,0,,0 PAC_F08 Pressure in mh O 8 I II 0 0,0 0,,0,,0,,0,,0 III PAC_F08 Note: As ALEZIO heat pumps are of the SPLIT INVERTER type with refrigeration link between the outdoor unit and the MIV-II module, it is not necessary to add glycol to the installation. Flow rate in m /h Flow rate in m /h Important comments regarding: The various emitters: The water outlet temperature on heat pumps is limited: C max. for AWHP. It is therefore imperative that they operate on low temperature emitters, i.e. underfloor heating/cooling or radiators sized at low temperature. For the cooling mode, only underfloor heating with compatible flooring and floor covering is suitable. It is also necessary that the underfloor cooling flow temperatures be respected, depending on the geographical location, to prevent the phenomenon of condensation (between 8 C and C). Refrigerant fluids: R0A refrigerant fluid has properties suitable for heat pumps. It belongs to the family of HFCs (hydrofluorcarbons), composed of chemical molecules containing carbon, fluorine and hydrogen. It does not contain chlorine and therefore does not damage the ozone layer. Storage tank The installation of a storage tank is recommended for installations in which the water volume is less than l/kw in heating output on the heat pump (remember to factor in the l in the MIV-II). It is intended: - on the one hand, to increase the water volume in an installation in order to limit the short-cycle operation of the compressor. The greater the water volume, the lower the number of startups of the compressor and the longer its useful life. - on the other hand, to guarantee an energy reserve for the defrosting phases. Filters In order to protect the exchanger on the MIV-II, installation of the filter is mandatory. The filter + gate valve unit (package EH ) can be delivered as optional. The cooling or air-conditioning mode So-called reversible heat pumps are used to produce a cooling effect in summer. A -way valve, called a cycle inverter valve, switches the cycle from heating mode to cooling mode. The compressor intake is thus linked to the indoor exchanger, which therefore becomes the evaporator. The compressor backflow is thus linked to the outdoor exchanger, which therefore becomes the condenser. Note: For Air/Water type heat pumps, this -way valve is also used for the defrosting phase on the evaporator. In the case of an installation with underfloor heating/cooling (outlet and return water temperature : +8 C/ C), the refrigeration output is limited, but sufficient to keep the home pleasantly comfortable. On average, it allows the ambient temperature to be reduced by to C. With an installation with fan-convectors (outlet and return water temperature : + C/ C) it is compulsory to use the HI or EI versions.

14 SET < > Dietrisol B EXAMPLES OF ALEZIO HEAT PUMP INSTALLATIONS The examples presented below cannot cover the full range of installation scenarios that may be encountered. Their purpose is to draw the attention to the basic rules to be followed. A certain number of control and safety devices are shown but it is ultimately up to experts, consultant engineers and design departments to take the final decision on the safety and control devices to be used in the boiler room according to its specificities. In all cases, it is necessary to abide by the codes of practice and prevailing regulations. ALEZIO- heat pump with indoor MIV-II/E module, with electrical back-up - direct underfloor heating circuit - DHW production by independant BL boiler - Cooling mode possible AD MIV-II/E a HA 0V or 00V 0Hz 0V or 00V 0Hz EH EH * EH M EH BUS 0 8 EH EH 8 0 EH AWHP MR * This package is delivered with ALEZIO AWHP MR-II BL.. PAC_F08G ALEZIO- heat pump with indoor MIV-II/EI module, with electrical back-up - direct fan convector circuit - DHW production by BESC... E electrosolar DHW tank - Air conditioning mode possible AD MIV-II/EI EH ** 0V or 00V 0Hz a HA 0V or 00V 0Hz EH EH * 0V or 00V 0Hz BUS 0 8 EH 0V 0Hz AWHP MR PAC_F0B EH Note: The conduits going to the fan convector units must be insulated. * This package is delivered with ALEZIO AWHP MR-II ** delivered with MIV-II/EI, to be mounted Key see page

15 EXAMPLES OF ALEZIO HEAT PUMP INSTALLATIONS ALEZIO- heat pump with indoor MIV-II/H module, with boiler back-up - direct underfloor heating circuit - DHW production by the boiler - Cooling mode possible MIV-II/H AD a HA Existing installation 0V 0Hz EH + EH EH 0V or 00V 0Hz EH BUS EH 0 8 0V 0Hz M AWHP.. MR/TR 0 8 Floor standing -service boiler PAC_F08D ALEZIO- heat pump with indoor MIV-II/H module, with boiler back-up - direct radiator circuit - DHW production by the boiler - Cooling mode not possible MIV-II/H AD a HA Existing Installation 0V 0Hz EH + EH EH 0V or 00V 0Hz EH BUS EH 0 8 0V 0Hz M AWHP MR/TR 8 0 PAC_F0 Key see page

16 EXAMPLES OF ALEZIO HEAT PUMP INSTALLATIONS ALEZIO- heat pump with indoor MIV-II/H module, with boiler back-up, B 80 T storage tank with bypass - direct "radiator" circuit - DHW production by independant BL boiler - Cooling mode not possible AD MIV-II/H a Existing Installation 0V or 00V 0Hz B80T EH EH 0V 0Hz BUS M 0V 0Hz EH EH + EH /H EH GTU 0 EH EH 0 8 BL.. PAC_F00B Key -bar safety valve Pressure gauge a Flowmeter Automatic air vent Isolation valve 0 -way mixing valve Heating pump Expansion vessel 8 Filling device Outside sensor Load pump Non-return valve DE DIETRICH THERMIQUE S.A.S. with corporate capital of 8 0, rue de la Gare - F - 80 Mertzwiller Tel Fax Domestic cold water inlet Pressure reducer 0 Sealed safety device calibrated to bar DHW loop back pump Decoupling cylinder C manual reset safety thermostat for underfloor heating 0 Disconnector Thermostatic valve Differential valve Thermometer Direct heating circuit: radiators Direct heating circuit:underfloor heating 8 Electrical resistance 8 Stop valve with unlockable nonreturn valve 8 Primary solar circuit pump 8 Safety valve calibrated to bar 88 Solar circuit expansion vessel 8 Container for solar fluid 0 Thermostatic mixer tap a Solar collector sensor b Solar DHW tank sensor Primary solar circuit filling and draining circuit Thermostatic distribution valve per zone -way reversal valve Solar control system Duo-pipes 0 Degasser with manual vent Collector field Filter + gate valves Motorised -way valve Important Recommendations In order to make the most of the performances of heat pumps for optimal comfort and to maximise their useful life, we recommend that you pay particular attention to their installation, commissioning and maintenance ; to do this, abide by the various instructions that come with the appliances. In addition, the De Dietrich catalogue offers a commissioning service for heat pumps ; we also strongly recommend that you take out a maintenance contract. 0/0 000B.. Strasbourg Companies Register Document not contractually binding - Printed in France - OTT Imprimeurs 0 Wasselonne - 08

ALEZIO EVOLUTION EASYLIFE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

ALEZIO EVOLUTION EASYLIFE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER ALEZIO EVOLUTION REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER AWHP -3/E and EI: from.7 to 14.6 with additional heating by integrated electrical resistance AWHP -4/E V200: from.7 to 14.6 with DHW-calorifier

More information

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER /E: from to kw with additional heating by integrated electrical resistance /H: from to kw with additional hydraulic heating by boiler (or without additional

More information

HPI EVOLUTION ADVANCE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

HPI EVOLUTION ADVANCE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER HPI EVOLUTION REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER HPI/E: from.8 to 2. with additional heating by integrated electrical resistance HPI/H: from.8 to 2. with additional hydraulic heating by boiler

More information

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS ZENA PLUS WALL-HUNG GAS BOILERS MSL FF: from. to 1 kw for heating only MSL FF + BMR 80 and MSL FF + SR 10: from. to 1 kw for heating and DHW produced by an 80-litre calorifier placed beside the boiler,

More information

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x * VIVADENS MCR-P WALL-HUNG GAS CONDENSING BOILERS MCR-P 24: from 6.3 to 25.0 kw, for heating only MCR-P 24/BS 80 and MCR-P 24/BS 130: from 6.3 to 25.0 kw, for heating and domestic hot water production by

More information

INDEPENDENT DOMESTIC CALORIFIERS

INDEPENDENT DOMESTIC CALORIFIERS BPB-BLC /BEPC /B /FWS INDEPENDENT DOMESTIC CALORIFIERS BPB : Performance, independent calorifiers, capacity to litres BLC : Comfort, independent calorifiers, capacity to litres BEPC : DHW calorifier litres

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

GT 120 >> >> >> <<   >> Sustainable Comfort. Longlasting comfort SOLAR SOLID FUEL HEAT PUMPS CONDENSING OIL/GAS GAS FLOOR STANDING BOILER ADVANCE Longlasting comfort >> >> >> Silence and durability Customized solutions and comfort Provides the quality of an integrated

More information

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS EMC-M : from 6.1 to.8 kw, for heating only EMC-M /BS 8 and EMC-M /BS 13: from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank, 8 or

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

BSC...E - BSP...E - BESC...E

BSC...E - BSP...E - BESC...E INISOL DUO E DIETRISOL DUO E Solar hot water calorifer BSC...E - BSP...E - BESC...E EN User Guide 0007781-001-01 Contents 1 Introduction.............................................................................

More information

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP AIR TO WATER HEAT PUMP ALFÉA EXCELLIA DUO Five models: 11 to 16 kw (single and -phase) Heating and domestic hot water integrated COP up to 4. Suitable for new build and renovation Integrated domestic hot

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort Ecodesign by FLOOR-STANDING OIL CONDENSING BOILER ADVANCE High technology with oil >> >> >> High performance modulating burner Compact boiler design Compatible with renewable energies SOLAR SOLID FUEL

More information

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A DIEMATIC WALL-MOUNTED CONTROL SYSTEM Electronic control system capable of controlling 2 heating circuits, a DHW circuit and an auxiliary circuit EC identification No.: 0085CM0178 Electronic microprocessor

More information

4FLOOR-STANDING GAS CONDENSING BOILERS

4FLOOR-STANDING GAS CONDENSING BOILERS EASYLIFE PROJECT / SOLNEO / ECODENS RESIDENTIAL DTG (E) 130-15/25 Eco. NOx Plus DTG (E) 1300-15/25 Eco. NOx Plus/B150 DTG (E) 1300-15/25 Eco. NOx Plus/H150 DTG 1300-15/25 Eco. NOx Plus/V130 4FLOOR-STANDING

More information

PMC-M WALL-HUNG GAS CONDENSING BOILERS

PMC-M WALL-HUNG GAS CONDENSING BOILERS PMC-M WALL-HUNG GAS CONDENSING BOILERS PMC-M : from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank BMR 8 or SR 13 PMC-M MI: from 6.1 to 35.7 kw, for heating and instant domestic

More information

PRODUCT CATALOGUE

PRODUCT CATALOGUE PRODUCT CATALOGUE 010- PROJECT INNOVENS PRO CA 5-115 from 8.9 to 11 (7.6-98.0 cal/h) Wall-hung gas condensing boilers P. PROJECT INNOVENS PRO CA 5-115 CASCADE SYSTES from 80 to 8 (68.8-368 cal/h) Complete

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution! SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Comfort Module 5-2 kw Choose the easy heating solution! Comfort Module: heating with Carrier system innovation Proper control of heat pumps is key to

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS GT CAST RON FLOOR-STANDNG FUEL OL-/GAS-FRED BOLERS GT : for hot water central heating only GT : for hot water central heating and domestic hot water production with a 16- or 5-litre calorifier under the

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature

More information

AWHP-2 MIT-IN-2 isystem

AWHP-2 MIT-IN-2 isystem HPI EVOLUTION Export EN Air / water heat pump AWHP- MIT-IN- isystem Installation and Service Manual 76637-00-04 Declaration of conformity The device complies with the standard type described in the EG

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

ECOCIAT. Domestic hot water heat recovery unit. Use. Range Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION

More information

<< >> Condensing technology at the service of oil. Controlling energy to save money

<<   >> Condensing technology at the service of oil. Controlling energy to save money SOLAR SOLI D FUE L H EAT PUMPS CON DE NSI NG OI L/GAS GTU C 120 O I L - F I R E D C O N D E N S I N G B O I L E R S ADVANCE Condensing technology at the service of oil >

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

8FUEL OIL CONDENSING BOILERS

8FUEL OIL CONDENSING BOILERS EASYLIFE PROJET GTU (FF) / WINGO SF (FF) GTU 0 GTU 0 FF GTU 00/V GTU 00 FF/V POWER RANGES GTU 0....-. kw... p. 9 GTU 00/V....-. kw... p. 9 GTU 00....-. kw... p. 9 GTU 0 FF....-. kw... p. 9 RESIDENTIAL

More information

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05 THERMAL SOLAR ENERGY CATALOGUE OCTOBER 2008 INDEX RENEWABLE ENERGY THERMAL SOLAR ENERGY RENEWABLE ENERGY...pag. 05 SISTEMA CS 25 RN TAU... pag. 6 SISTEMA CS 25 RN - CS 25 RN PLUS... pag. 8 SISTEMA CSL

More information

GTU C 220 FUEL OIL CONDENSING BOILERS

GTU C 220 FUEL OIL CONDENSING BOILERS GTU C FUEL OIL CONDENSING BOILERS GTU C : fuel oil condensing boilers from to 85 kw for hot water central heating only Heating only (DHW production by independent tank) Condensing boiler Domestic Fuel

More information

PAC BT LOW TEMPERATURE HEAT PUMP

PAC BT LOW TEMPERATURE HEAT PUMP PAC BT LOW TEMPERATURE HEAT PUMP Just feel well COP up to. EER up to. PAC BT -7 kw A ++ + PRODUCTS Cooling and heating mode. Monobloc system. Available in 3PH (sizes 1 to 1). High flexibily due to DC Inverter

More information

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION C /6- ECO FLOOR STANDING GAS CONDENSING OILERS C - Eco: from 56 to 5 kw, gas condensing boilers simple body, for hot water central heating and DHW production with independent calorifier C 6- Eco: from

More information

environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery

environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery made in France www.ett.fr energie transfert thermique c o n t e n t s General description...

More information

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump HEAT PUMP WATER HEATER EXPLORER 7% energy savings * Wide temperature range of use (- to + C) ACI hybrid anti-corrosion protection Smart energy consumption control Remote piloting with Cozytouch technology

More information

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS GT CAST RON FLOOR-STANDNG FUEL OL- / GAS-FRED BOLERS GT : for hot water central heating only GT : for hot water central heating and domestic hot water production with a 16- or 5-litre calorifier under

More information

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex. A-Class A-Rated Homes with Dimplex heat pumps Building Regulations and Part L Compliance made easy with Dimplex. The name you can trust. dimplex.ie AClass A4 Page Brochure-August 2016.indd 1 A-Class Heat

More information

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS EMC-M : from 6.1 to.8 kw, for heating only EMC-M /BS 8 and EMC-M /BS 13: from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank, 8 or

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION FLOOR-STANDING GAS CONDENSING BOILERS FROM.4 TO 5.KW AGC 15-25-5: for heating only AGC /V 100 HL: for heating and DHW production by 100 litre stratification calorifier placed under the boiler AGC /V 0

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI Vivadens EN Wall-hung gas condensing boilers MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI User Guide 300015874-001-B Contents 1 Introduction...4 1.1 Used symbols...4 1.2 Abbreviations...4 1.3 General...4

More information

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as

More information

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma

More information

Inverter Hot Water Heat Pumps

Inverter Hot Water Heat Pumps Inverter Hot Water Heat Pumps Inverter Hot Water Heat Pumps Hot Water Heat Pump Systems Underfloor Heating Swimming Pools Spa Pools Sanitary Water Pre-heating Hydroponics Aquaculture Water Chilling Hot

More information

DTG Eco / V130

DTG Eco / V130 ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C Air-water split heat pump. COP > 4 ACS a 60 C Energy class: 35 55 RENEWALE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

and sanitary hot water Catalogue 2009

and sanitary hot water Catalogue 2009 heating, COOLING and sanitary hot water Catalogue 2009 LG Electronics Magyar Kft. H-1097 Budapest, Könyves K. krt. 3/a. (+36-1) 455-6060 www.lg.hu www.lgeaircon.com http://lgacademy.csx.hu For continual

More information

ADVANCE EASYLIFE PROJECT

ADVANCE EASYLIFE PROJECT ADVANCE EASYLIFE PROJECT DIEMATIC 3 and -m 3 control panels... p. 232 DIEMATIC isystem control panel... p. 234 DIEMATIC 3 DIEMATIC VM isystem wall-hung control unit... p. 235 Room thermostats and miscellaneous...

More information

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER High energy efficiency with the R410A Compact and silent Scroll compressors Inverter technology High performance brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 40 to 80

More information

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

Industrial and collective. With coil exchanger. Technical data. Initial heat-up. surface area. Exchanger. Exchanger capacity.

Industrial and collective. With coil exchanger. Technical data. Initial heat-up. surface area. Exchanger. Exchanger capacity. Industrial and collective Calorifiers and Combi With coil A compact, safe solution for producing hot water from multiple energy sources, including solar energy. Operation Semi-instantaneous hot water production

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

NATURAL HEATING MACHINE

NATURAL HEATING MACHINE www.lgeaircon.com LG Electronics Air Conditioning & Energy Solution 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 55 Seoul 150-721, Korea Phone: 82-2-777-761 http://www.lgeaircon.com For continual product

More information

BWL air heat pumps BWS brine heat pumps

BWL air heat pumps BWS brine heat pumps BWL air heat pumps BWS brine heat pumps Wolf - Heat pumps Benefits offered by Wolf heat pumps From each 1 kwh power, heat pumps generate between 3 and 5 kwh heat Free environmental energy from the ground

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

AQUAHEAT ADVANCE SPLIT

AQUAHEAT ADVANCE SPLIT AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B Vivadens EN Wall-hung gas condensing boilers MCR 24/28 BIC User Guide 300024112-001-B Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 General...4 1.3.1 Manufacturer's liability...4

More information

ACCUMULATION OF EUROPEAN CLASS

ACCUMULATION OF EUROPEAN CLASS ACCUMULATION OF EUROPEAN CLASS Total comfort MODEL nominal output kw minimum output kw DUA PLUS B TN DUA PLUS B TFS natural draught room sealed forced draught 28 12.4 28 12.4 DUA PLUS B was born from the

More information

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank 1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO

More information

ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS AQUACOOL. Water-to-water heat pump with passive energy recovery.

ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS AQUACOOL. Water-to-water heat pump with passive energy recovery. ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS AQUACOOL Water-to-water heat pump with passive energy recovery www.ett.fr ENERGIE TRANSFERT THERMIQUE C O N T E N T S General description... 3 Operating

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

NUOS RANGE HEAT PUMP WATER HEATERS

NUOS RANGE HEAT PUMP WATER HEATERS RANGE HEAT PUMP WATER HEATERS 1 HOW TO READ THE SYMBOLS The icons have been designed to facilitate the reading of the features of each product. Ariston makes it possible, from the very beginning, to quickly

More information

TWH 200E TWH 300E TWH 300EH

TWH 200E TWH 300E TWH 300EH KALIKO Export EN Thermodynamic water heater TWH 200E TWH 300E TWH 300EH Installation and Service Manual C003182-B 300026515-001-05 Declaration of conformity The device complies with the standard type described

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

MODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33

MODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33 Inverter-driven air source heat pump systems Dimplex Air-Eau is an exciting new range of inverter-driven air source heat pumps designed to match output to varying heating demand. With achievable CoPs of

More information

Modulens G >> >> >> Condensing in excellence mode

Modulens G >> >> >> Condensing in excellence mode Modulens G FLOOR-STNDING GS CONDENSING BOILER Ecodesign by DVNCE Condensing in excellence mode >> >> >> Environmental friendliness and energy savings Maximum domestic hot water comfort Compatible with

More information

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element =Classic range= Classic range technologies Magnesium anode The magnesium anode is located in the centre of the enamelled tank and provides excellent protection against corrosion; this anode is consumed

More information

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER SHERP ir-water heat pump COP > 4 DHW 60 C Energy class ErP (1) : RENEWLE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability. Protecting installations Energy optimisation Improved profitability Flow rate of conditioned biogas: up to 6 000 Nm 3 /h Biogas efficient waste recovery Operating principle When produced, biogas contains

More information

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection Data sheet LIH 26TE High temperature air-to-water heat pump Max. flow temperature: 75 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

STORAGE WATER HEATERS

STORAGE WATER HEATERS Owners Manual STORAG WATR HATRS RBC 200, RBC 300, RBC 400, RBC 500, RBC 500HP, RBC 750, RBC 1000, RBC 1000HP, RBC 1500, RBC 2000, RBC 3000 N v. 1.4 CONTNTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection...

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP 1 Enjoy comfortable life with BLUEWAY DC Inverter Air to Water Heat Pump is an innovative system of house heating, domestic hot water and even space cooling,

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

B 150p to B 500p. Independent domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions.

B 150p to B 500p. Independent domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions. B 150p to B 500p Independent domestic hot water tanks English 25/04/06 Installation instructions Instructions for use Technical instructions 94870007 Contents Introduction.................................................................................3

More information

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until) Data sheet LA 16MS Air-to-water heat pump with deflector hoods Max. flow temperature: 58 C Casing colour: White aluminium (similar to RAL 9006) Air-to-water heat pump for outdoor installation with external

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C SOLNEO EN Gas fired condensing boiler SGC 24 SOL User Guide 300017555-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information