REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES

Size: px
Start display at page:

Download "REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES"

Transcription

1 / ACCESSORIES

2 High performance Lightest vacuum pump VACUUM PUMP.8CFM Eco Applicable to room air-conditioner, package air conditioner up to 5HP.8CFM Eco Code No.WV0 Suitable for vacuuming small 5HP refrigeration. Code No.WV (0 0V) 3.0Pa abs. ~5HP class 50L/ min Suitable for vacuuming small equipment REFRIGERANT SERVICE TOOLS High precision stage vacuum pump Exhaust Intake pole condenser motors is 5 microns which is the highest level for the small Vacuum Pump. Two rotary pumps are placed in series to get larger compression ratio for lower pressure. (higher vacuum). Enough exhaust speed performance although it is compact designed. Strengthen the capacity under low temperature or voltage Reinforcement of starting and operating efficiency with a new motor when it s under low temperature or voltage. Bult-in metal mesh filter Large diameter exhaust port Reduce oil-mist specific to oil rotary vacuum pumps. Large diameter port for oil charging and exhaust. Pump speed Motor Oil capacity Intake Standard accessorie.8cfm Eco Gauge Kit Code No.WV0CG 60mm L/min (50Hz) 50L/min (60Hz) 3.0Pa abs. (5micron),880min (50Hz) 3,0min (60Hz) Voltage made to order 00W 5.0kg 50ml /", 5/6" (Flare male) oil 0.3L, Adaptor /" female M0 male and ultimate vacuum are according to our own survey. Code No.WVCG (0 0V) 3.0Pa abs. 05mm 00mm ~5HP class 50L/ min The most suitable Vacuum Pump.8CFM Eco Kit with Vacuum Gauge with a valve for vacuum check and Case. Solenoid check valve Prevent vacuum pump oil from flowing backward. Prevent damage to HFC systems by backward flow of oil. With over load protection Protect motor from getting damage by over loading. Cooling fan Send air from back to front to prevent motor and pump from heating up. Radiating fins Enable to run long time. Sight glass Large sight glass for easy monitoring of the oil level and condition. Standard accessorie.8cfmeco, Small vacuum gauge with a valve, Adaptor /" female 5/6" male, Case, oil 0.3L, Adaptor /" M0 male

3 Applicable to various equipment! Ultra- high - spec models! VACUUM PUMP Eco SERIES Built-in high precision - stage & forced lubrication pump Realize higher vacuum. Improved oil film performance for longer service life. CFM Eco Code No.WV0 Code No.WV (0 0V) Built-in forced lubrication pump prevents the unit from damaging due to insufficient oil volume. Suitable for vacuuming small to 7HP class refrigeration equipment!! ~7HP class 57L/ min Stage Forced Iubrication 30mm Exhaust Intake Two rotary pumps are placed in series to get larger compression ratio for lower pressure. (higher vacuum). Equipped with a pole high torque motor Ultra high performance vacuum pump which can start and run stably even in wintertime or at low voltage by two capacitors for starting and running. (6 8CFM Eco) Equipped with a start capacitor for stable starting even in wintertime or at low voltage. ( CFM Eco).0Pa (5 micron) Realize high vacuum by high precision machining technology. ( 6 8CFM Eco) Oil Intake port Built-in forced lubrication pump prevents vacuum pump from damage due to insufficient oil volume. Bult - in metal mesh filter Reduce oil-mist specific to oil rotary vacuum pumps. Pump speed Motor Oil capacity Intake port 308mm 5L/min (50Hz) 57L/min (60Hz) (5 micron),0min (50Hz),70min (60Hz) Voltage made to order 50W 9.kg 60ml /", 5/6" (male flare) oil 0.35L, Adapter /" female flare M0 male flare and ultimate vacuum are according to our own survery. CFM Eco Gauge Kit Code No.WV0CG mm Code No.WVCG (0 0V) ~7HP class The most suitable Vacuum Pump CFM Eco Kit with Vacuum Gauge with a valve for vacuum check and Case. Large diameter exhaust port Large diameter port for oil charging and exhaust. With over load protection Protect motor from getting damage by over loading. Solenoid check valve Prevent vacuum pump oil from flowing backward. Prevent damage to HFC systems by backward flow of oil. Cooling fan Send air from back to front to prevent motor and pump from heating up. Gas ballast valve High speed evacuation. Keep oil clean during evacuation of wet system. Radiating fins Enable to run long time. Sight glass Large sight glass for easy monitoring of the oil level and condition. CFMEco, Small vacuum gauge with a valve, Adaptor /" female 5/6" male, Case, oil 0.35L, Adaptor /" female M0 male

4 CFM Eco Code No.WV0 Code No.WV (0 0V) Suitable for vacuuming small to 0HP class refrigeration equipment!! ~0HP class 3L/ min Built-in forced lubrication pump prevents the unit from damaging due to insufficient oil volume. CFM Eco with gauge and carrying case CFM Eco Gauge Kit Code No.WV0CG CFMEco with single vacuum manifold and carrying case. ~ 0HP class Code No.WVCG (0 0V) REFRIGERANT SERVICE TOOLS 65mm 335mm 38mm 00L/min (50Hz) 3L/min (60Hz) (5 micron) Pump speed,0min (50Hz),70min (60Hz) Motor Voltage made to order 375W.kg Oil capacity 390ml Intake port /", 3/8" (male flare) Standard accessories oil 0.35L pcs, Adapter /" female flare 5/6" male flare, Adapter /" female flare M0 male flare and ultimate vacuum are according to our own survery. CFMEco, Single vacuum manifold, Adapter 3/8" female flare /" male flare, oil 0.35L pcs, Adapter /" female flare 5/6"male flare pcs, Adapter /" female flare M0 male flare, Case 6CFM Eco Built-in forced lubrication pump prevents vacuum pump from damaging due to insufficient oil volume. ~30HP class 70L/ min Double capacitor increases startability at low temperature! Suitable for vacuuming small to 0HP class refrigeration equipment!! 8CFM Eco Code No.WV60 Code No.WV6 (0 0V) Code No.WV80 Code No.WV8 (0 0V) Built-in forced lubrication pump prevents vacuum pump from damaging due to insufficient oil volume. ~ 5HP class 6L/ min Double capacitor increases startability at low temperature! Suitable for vacuuming small to 5HP class refrigeration equipment!! 90mm 300mm 390mm 5mm L/min (50Hz) 70L/min (60Hz) (5 micron) Pump speed,0min (50Hz),70min (60Hz) Motor Voltage made to order 550W 6.5kg Oil capacity 580ml Intake port /", 3/8" (male flare) Standard accessories oil 0.35L pcs, Adapter /" female flare 5/6" male flare, Adapter /" female flare M0 male flare and ultimate vacuum are according to our own survery. 98L/min (50Hz) 6L/min (60Hz) (5 micron) Pump speed,0min (50Hz),70min (60Hz) Motor Voltage made to order 550W 7kg Oil capacity 60ml Intake port /", 3/8" (male flare) Standard accessories 395mm oil 0.35L pcs, Adapter /" female flare 5/6" male flare and ultimate vacuum are according to our own survery. 53mm 3

5 High performance High quality Long life supreme vacuum pump!! VACUUM PUMP SERIES For vacuuming and dry of Auto A/C, large refrigerator, commercial refrigeration system, room A / C, package A/C system CFM Code No.Y9359 For vacuuming of small 0HP class refrigeration equipment. ~0HP class 6L/ min st Stage (Intake) st Stage (Exhaust) High efficient - stage rotary pump For increased efficiency, the first stage exhausts into the second stage similar to using two single stage pumps connected together. YELLOW JACKET s used in all over the world Suitable for long time vacuuming works!! Equipped with a pole high torque motor.0pa (5 micron) 93mm Silent operation. Increase startability at low temperature and low voltage. Realize high vacuum by high precision machining technology. Bult-in check valve Large diameter exhaust port Prevent vacuum pump oil from flowing backward. Prevent damage to HFC systems by backward flow of oil. Large oil drain plug Large oil drain plug with easy access for fast, clean oil changes. With over load protection Protect motor from getting damaged by over loading. Gas ballast valve High speed evacuation. Keep oil clean during evacuation of wet system. Large diameter port for oil charging and exhaust. Buit - in vacuum gauge Check vacuum condition. Radiating fin Enable to run long time. Sight glass Large sight glass for easy monitoring of the oil level and condition. 3mm 56mm 95L/min (50Hz) 6L/min (60Hz) (5 micron) Pump speed,5min (50Hz),75min (60Hz) Motor Voltage made to order 375W 5.kg Oil capacity.08l Intake /", 3/8" (male flare) Adapter /" female flare 5/6" male flare, oil.l and ultimate vacuum are according to our own survery. Prevent oil mist from scattering Oil Exhaust Filter Code No.Y93386 Screws onto pump exhaust to eliminate oil mist. Maintains the environment in the closed space and relives the operator's burden. Applicable to YELLOW JACKET VACUUM PUMP ( 8 6FM) 380g Thread size NH 3/" Suitable model 6 8CFM Replacement Filter Clean vacuuming without oil mist!! Code No. Y93387

6 6CFM Code No.Y93569 For vacuuming of small to large refrigeration equipment. Abundant product line up suitable for various condition ~30HP class 7L/ min Latest evacuation method & technology Latest technology and high performance vacuuming system realize to increase the benefit. High speed & high vacuum High speed, is more than.0pa of.0pa is enough capacity to eliminate contamination causing trouble on equipment. REFRIGERANT SERVICE TOOLS Abundant product line up brings vaccum pump's ability into full play. 5 Suitble for long time vacuuming and vacuuming from small to 30HP class refrigeration equipment! 3 Vacuum Pump Manifold for Vacuuming 3 Vacuum Guage 3/8" Charging Hose 93mm 5 Quick Charging Valve Pump speed L/min (50Hz) 7L/min (60Hz) (5 micron),5min (50Hz),75min (60Hz) 3mm Motor Voltage made to order 375W 6.kg Oil capacity.0l Intake /", 3/8" (male flare) 56mm Adapter /" female flare 5/6" male flare, oil.l and ultimate vacuum are according to our own survery. 8CFM Code No.Y93589 For vacuuming of small to large refrigeration equipment. Abundant product line up suitable for various condition Abundant product line up brings vaccum pump's ability into full play. ~5HP class 9L/ min Latest evacuation method & technology Latest technology and high performance vacuuming system realize to increase the benefit. High speed & high vacuum High speed, is more than.0pa of.0pa is enough capacity to eliminate contamination causing trouble on equipment. 5 Suitble for long time vacuuming and vacuuming from small to 5HP class refrigeration equipment! 3 3 Vacuum Pump Vacuum Guage Pump speed 90L/min (50Hz) 9L/min (60Hz) (5 micron),5min (50Hz),75min (60Hz) Manifold for Vacuuming 3/8" Charging Hose Quick Charging Valve Motor Voltage made to order 375W 7.0kg 5 mm 93mm Oil capacity.9l Intake /", /" (male flare) Adapter /" female flare 5/6" male flare, Adapter /" female flare 3/8" male flare, oil.l 56mm and ultimate vacuum are according to our own survery. 5

7 VACUUM PUMP IMPORTANCE OF CHANGING OIL After vacuuming operation, recommend to change oil to new while the oil is still warm to remove pollutants with the oil before they are precipitated. By changing oil regulary and keeping oil clean, prevent deteriorations of performance, efficiency of pump and also the pump unit from being worn and corroded. Worn and corroded pump unit can not be recovered even change its oil. For checking vacuum condition in the system Digital Vacuum Gauge evacⅠ Code No.Y6907 Special vacuum pump oil Vacuum Pump Oil 0.5L : Code No.VP L :Code No.Y L :Code No.Y L :Code No.Y L 0.7L 0.95L 3.80L Item Capacity Quantity Vacuum Pump Oil 0.5L 0.7L 0.95L 3.80L Display the vacuum level with numerical value and bar graph. With warning function to protect the sensor from oil. Can proofread manually after measuring. With back light and muffling function. Measuring range Sensor Working temperature Power source For checking vacuum condition in the system Electronic Vacuum Gauge PAT.P Code No.Y69086 Automatic shut-off Pa abs. (5000micron)~0Pa abs. (0micron) Thermistor ~50 C 9V alkaline battery 0.7kg 9V alkaline battery, Adaptor Low battery indicator Automatic ambient temperature compensation. Coilded sensor cord streches to 300~600mm for easy reading. Ideal tool for vacuuming Dispaly Dispaly 7 different units of vacuum. Ideal for checking degree of vacuum! Usable in narrow areas with a cable 75mm typed sensor! 65mm 30mm Measuring range Sensor Working temperature Power source Pa abs. (5000micron) ~.33Pa abs. (0 micron) Thermal conductivity sensor 0~9 C 9V alkaline battery 0.3kg (including battery) Thermal conductivity sensor Replaceable plug - in sensor. For checking vacuum condition in the system Electronic Vacuum Gauge PAT.P (high precision vacuum measuring device) Code No.Y69075 Low battery indicator Quick responding detachable electronic sensor. Measures degrees of vacuum in refrigeration cycle. With temperature correction control. Measuring range Sensor Working temperature Power source Pa abs. (760,000 micron) ~0.33Pa abs. ( micron) Thermal conductivity sensor 0~9 C Alkaline battery.3kg To check degree of vacuum in area where accuracy specially required!! 30mm 30mm 60mm 6

8 Manifold with vacuum gauge Vacuum Single Manifold Code No.VT0 Vacuum gauge Port size 0~ 0.MPa /" Flare (UNF 7/6 0TPI) Easy to operate with ball valve. Ideal for testing after vacuuming with friction pointer. Ideal for checking vacuum retention!! Easy to find leakage with big gauge and friction pointer!! REFRIGERANT SERVICE TOOLS Pressure range Gauge diameter Port size 0~ 0.MPa ø80mm /" Flare female /" male with ball valve Adapter for different diameter (/" Flare female 5/6" Flare male) Vacuum gauge (with ball valve) for vacuum pump Small Vacuum Gauge with Valve Code No.XP76 Just install to /" port, can check pressure and vacuum retention easily!! /" Flare male Pressure range Gauge diameter Applicable vacuum pump 0~ 0.MPa ø0mm Adapter for different diameter (/" Flare female 5/6" Flare male).8cfmeco, CFMEco /" Flare female For vacuum testing of plumbing Vacuum Test Gauge Code No.Y0005A For vacuuming of A/C, for checking vacuum pump and vacuum test for pipings. For vacuum test of systems after refrigerant recovery and for checking vacuum degree inside of cylinder. Screw diameter Pressure display Flare /" female 0~ 0.MPa For vacuum check in recovery cylinder Hose with Vacuum Gauge Code No.Y0003A For checking the degree of vacuum in cylinder before the refrigerant recovery. Before recovering gas side Check cylinder before recovery Before filling Screw diameter Pressure display Flare /" female 0~ 0.MPa Check system after recovery 7

9 Need of vacuuming as seeing from a leakage prevention Imperfect vacuuming Mixed air Mixed air Abnormal pressure during operation Abnormal pressure during operation Trouble of system running of safety valve Leakage of refrigerant Burn out, corrosion, and break of system caused by acid content Damage by clogging Enough vacuuming How to check degree of vacuum of Digital vacuum gauge Electronic vacuum gauge ( ) Change the vacuum pump oil. Install digital vacuum gauge to vacuum pump after switching on. Caution: Please use a copper pipe when connecting. (If using a charging hose, the measurement will be a failure.) 3 Read the scale after 5 to 0 minutes. If the scale is below 00Pa (absolute pressure) no problem to use. 5 If not reaching yet, do Power Flushing and check the pressure again. 6 If the degree of vacuum is still not enough, repairing of pump unit is necessary. Digital vacuum gauge evacⅠ 8

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution. As a specialized enterprise in making vacuum pumps, we have devoted ourselves to satisfy our customers need for high quality products. We adopt the latest designs and technology to make sure that our products

More information

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4. 1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4. INSTALLATION OF THE INDOOR UNIT 5. CONDENSATE HOSE CONNECTION

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96

More information

CC Series VACUUM PUMPS

CC Series VACUUM PUMPS CC Series VACUUM PUMPS OPERATING MANUAL Thank you for selecting a Javac select product! Please read this operation manual carefully before use. Only suitably qualified personnel should operate this equipment.

More information

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge. Manifold Gauge LD.R1.01 manifold gauge brass body LD.R1.02 manifold gauge brass body LD.R1.03 manifold gauge aluminum body LD.R1.04 manifold gauge aluminum body LD.R1.05 manifold gauge aluminum body LD.R1.06

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV20 LARGE CAPACITY REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01101 LV20.DOC NRP-OM-LV20

More information

ROCOOL For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique

ROCOOL For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique i ROCOOL 600 - For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique modular system 262 Refrigeration & Air- Conditioning

More information

O NEof Premium tools for professionals!

O NEof Premium tools for professionals! O NEof 6.000 Premium tools for professionals! 284 Refrigeration & Air Conditioning Technology System Overview 286-287 Complete Solutions Comissioning & Maintenance 288-290 Evacuation & Charging 290 Refrigeration

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G 2008 Fusion Subarticles Report a problem with this article Refrigerant System Recovery Refrigerant System Evacuation Using a R-134a Refrigerant Management Machine Refrigerant System Evacuation Using a

More information

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION Service Application Manual SAM Chapter 630-158 Section 2C DEEP VACUUM: ITS PRINCIPLE AND APPLICATION Adapted from material provided by JB Industries. Reprinted with permission. INTRODUCTION With the deep

More information

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS Classification: Reference: Date: HA94-005 NTB94-091 September 26, 1994 SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS APPLIED VEHICLE(S): All models except Quest equipped with a retrofitted A/C system SERVICE

More information

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES PROMAX RECOVERY DEVICES PROMAX designs, engineers, and manufacturers the highest quality service equipment and makes it easy to use for all refrigerant handling

More information

Refrigeration and AirConditioning Equipment

Refrigeration and AirConditioning Equipment 320 Refrigeration and AirConditioning Equipment System Overview Refrigeration and Air-Conditioning Equipment Fully Automatic Vacuum and Charging Stations Recovery and Recycling Units High Vacuum Pumps

More information

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700 A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds.

Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds. Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds. Discover the smart world of air conditioning system maintenance. The testo Smart

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE

More information

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm Atlas Copco Oil-sealed rotary screw vacuum pumps GVS 30-400, 35-3000 cfm Reliable general vacuum for critical applications Atlas Copco, the industry leader in compressed air solutions, has transferred

More information

REFRIGERANT RECOVERY SYSTEMS

REFRIGERANT RECOVERY SYSTEMS REFRIGERANT RECOVERY 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY YELLOW JACKET HVAC&R HOSES YELLOW JACKET YJ-LTE Refrigerant

More information

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System Certified by ITS to meet SAE J2810 for R-134a Designed to meet new SAE J2851 for R-1234yf MANUAL GENERAL INFORMATION Table of

More information

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC. Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER

More information

OPER LV Wheeler Way

OPER LV Wheeler Way OPER RATING INSTRUCTIONS LV5 REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 Ph:(215) 638-8909 9 info@ @nrproducts.com LV5.DOC 9.17.2018 MODEL LV5 REFRIGERANT

More information

EVac II Programmable Digital Vacuum Gauge

EVac II Programmable Digital Vacuum Gauge EVac II Programmable Digital Vacuum Gauge Thank you for your purchase of the YELLOW JACKET evac II Digital Vacuum Gauge. The evac II is the most accurate and precise vacuum gauge available today with patented

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! NEW 4,6,8,16,24,30 APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify

More information

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf Driven by CLIMATISATION Excellence for professionals Bosch air conditioning service units for R-134a and R-1234yf A/C service from Bosch Air conditioning systems in vehicles require regular maintenance.

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

for Light Commercial Use

for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 4 Toshiba's unique energy-efficient air conditioning innovations and technologies deliver high energy savings. Aluminum heat exchanger * High heat exchanger

More information

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! NEW APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify your work.

More information

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in

More information

OPERATION & MAINTENANCE MANUAL TX600

OPERATION & MAINTENANCE MANUAL TX600 OPERATION & MAINTENANCE MANUAL TX600 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80118-00 (Rev B) ! TABLE OF CONTENTS! TX600 Before Using Page 2 Safety Precautions Page

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which

More information

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4

More information

HERO SERIES-DC INVERTER HEAT PUMPS

HERO SERIES-DC INVERTER HEAT PUMPS HERO SERIES-DC INVERTER HEAT PUMPS PHNIX DC inverter heat pump can work efficiently with floor heating, water fan coils or radiators for heatingcooling. WATER FAN COILS DC INVERTER HEAT PUMP FLOOR HEATING

More information

R100 Oil-Less Refrigerant Recovery Unit

R100 Oil-Less Refrigerant Recovery Unit R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines

More information

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM WHAT ARE THE SPECIFICATIONS FOR THE VACUUM PUMPS NEEDED TO OPERATE THE JOULE THOMSON REFRIGERATORS? INTRODUCTION TO VACUUM PUMP USAGE Joule Thomson refrigerators have a wide temperature range to operate

More information

HFO1234 Material. MANIFOLDS: HFO1234 approved MV2HFO set - 2 way Valve deep vacuum manifold way - gauges 80MM HFO carton box 85,26

HFO1234 Material. MANIFOLDS: HFO1234 approved MV2HFO set - 2 way Valve deep vacuum manifold way - gauges 80MM HFO carton box 85,26 HFO1234 Material MANIFOLDS: HFO1234 approved MV2HFO set - 2 way Valve deep vacuum manifold way - gauges 80MM HFO1234 - carton box 85,26 MV2HFOS5QC set - 2 way Valve deep vacuum manifold - gauges 80MM CL1.0

More information

AIR CONDITIONER CONSOLE

AIR CONDITIONER CONSOLE Installation manual ENGLISH AIR CONDITIONER CONSOLE English Indoor unit console type IT IS MANDATORY TO CUT OFF POWER SUPPLY BEFORE STARTING TO WORK IN THE ELECTRIC CASING BOXES. GENERAL RECOMMENDATIONS

More information

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc. 1 High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A Hitachi Appliances, Inc. 2 Introduction The situation faced by the refrigeration / air conditioning industry

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21, TRS21C, TRS21S Evaluated for

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance

More information

RECOVERY, RECLAIM & DECOMPOSITION OF FLUOROCARBON

RECOVERY, RECLAIM & DECOMPOSITION OF FLUOROCARBON RECOVERY, RECLAIM & DECOMPOSITION OF FLUOROCARBON REFRIGERANT RECOVERY, High speed professional recovery machine ECO SAVER V230 SP Recovery and charging of refrigerant in case of diposal, replacement,

More information

Thermo Scientific Air Cadet

Thermo Scientific Air Cadet Thermo Scientific Air Cadet Vacuum/Pressure Pumps Air Cadet Vacuum Pumps Features A B C Compact size makes pumps ideal for portable applications. All-plastic, convoluted diaphragm design handles many vacuum/pressure

More information

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY Pro-Set TR500 SERIES Oilless Refrigerant Recovery System OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR500, TR500E, TR500J, TR500S TO BE OPERATED

More information

Customized Industrial Products

Customized Industrial Products Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds

Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds Matériels et outillages Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds Flexibles et raccords Outillages

More information

USER MANUAL UN-200V / UN-200VH

USER MANUAL UN-200V / UN-200VH USER MANUAL UN-200V / UN-200VH CONTACT US PHONE/FAX Toll Free: 800.465.1004 Phone: 801.486.1004 Fax: 801.486.1007 ADDRESS LACO Technologies, Inc. 3085 West Directors Row Salt Lake City, UT 84104 WEB www.lacotech.com

More information

OPERATION & MAINTENANCE MANUAL RHS680

OPERATION & MAINTENANCE MANUAL RHS680 OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup

More information

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities. Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities. The Laboratory chambers incorporate a number of sophisticated technologies

More information

Refrigerant Recovery/Recharging Series

Refrigerant Recovery/Recharging Series TrustworthyBrandChinaChunMu Refrigerants TrustworthyBrandChinaChunMu 2012 Refrigerant /Recharging Series Portable Refrigerant /Recharging Unit Light Commercial HVAC Industrial Refrigeration System Automotive

More information

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM OPERATION MANUAL Index I Caution.... 2 II Notation.. 2 III Technical parameter...3 IV Functions... 3 V Device Description. 3 (I) Control panel. 4

More information

Refrigeration air dryer

Refrigeration air dryer Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air

More information

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton Service Literature Corp. 0903 L1 Revised: March 2011 TSA SERIES UNITS TSA 6, 7.5, 10, 12.5, 15 & 20 ton The TSA units are designed for light commercial applications, with a remotely located blower coil

More information

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario TIF9055 Programmable Refrigerant Meter Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario TABLE OF CONTENTS 1 General Information 2 Features 3 Controls

More information

SECTION 50 - CAB CLIMATE CONTROL

SECTION 50 - CAB CLIMATE CONTROL AIR CONDITIONING SYSTEM DYNAMIC DESCRIPTION The refrigerant circuit of the air conditioning system contains five major components: Compressor, Condenser, Receiver/Drier, Expansion Valve, and Evaporator.

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Mode Temp Room Air Conditioner Service and Parts Manual 0F Fan Speed hr Timer 0n/0ff Money Saver Fan Only Auto Swing Power CP10 CP12 CP10 - CP12 (06/14) 93011402_04 CONTENTS 1. PREFACE 1.1 SAFETY

More information

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE Fluid Exchange Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories 423 ASCOT 424 Refrigerant Recovery/Recycling Systems Recovery and Recycling Systems

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS The Most Advanced Technologies for High-Quality air High-precision processing technology is required to produce the components that make up a Scroll Compressor.

More information

[FLARE CONNECTION TYPE] ATTENTION

[FLARE CONNECTION TYPE] ATTENTION SPLIT-TYPE AIR CONDITIONERS Model MXZ-2A20NA [FLARE CONNECTION TYPE] HFC utilized R410A INSTALLATION MANUAL ATTENTION This manual mentions how to install only the outdoor unit, MXZ-2A20NA. As for the way

More information

evac Pro Programmable Digital Vacuum Gauge Operation and Maintenance Manual

evac Pro Programmable Digital Vacuum Gauge Operation and Maintenance Manual evac Pro Programmable Digital Vacuum Gauge Operation and Maintenance Manual Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Introduction Thank you for

More information

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Refrigerant Installation Quick Reference Guide

Refrigerant Installation Quick Reference Guide Refrigerant Installation Quick Reference Guide To be used only by experienced and licensed refrigeration technicians Preface: This project objective is to replace existing CFC or HCFC refrigerants with

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

AIR CONDITIONNING 95 CODE 002

AIR CONDITIONNING 95 CODE 002 CODE 002 AIR CONDITIONNING 95 Cool-Tech Refrigerant Recovery/Recycling Unit Model 34788 It recovers, recycles, evacuates, leak tests, and recharges R-134a quickly and accurately. Fully automatic function

More information

Caresaver Universal Refrigerant Recovery Unit

Caresaver Universal Refrigerant Recovery Unit Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2

More information

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING Room Air Conditioner Service & Parts Manual 2014-2015 EP08 & EP12 Chill 115 Volts-EP08 230 Volts-EP12 THE EXPERTS IN ROOM AIR CONDITIONING 93011407_00 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

OPERATING the HIGH ALTITUDE VACUUM CHAMBER

OPERATING the HIGH ALTITUDE VACUUM CHAMBER OPERATING the HIGH ALTITUDE VACUUM CHAMBER Howard L. Brooks, Principal Investigator Department of Physics and Astronomy DePauw University Greencastle, IN 46135 hlbrooks@depauw.edu 6 January 2014 Table

More information

BAC 4000a BAC 5000yf

BAC 4000a BAC 5000yf AC Service Units BAC 4000a BAC 5000yf AC Service Units Recommended by Volvo Cars Fully-automatic, high capacity and comfortable Maximum safety Easy to use BAC 4000a Maximum precision easy operation. The

More information

Measurement Solutions for Refrigeration Technology.

Measurement Solutions for Refrigeration Technology. Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. 01_Brochure_testo552_MASTER.indd 1 30.01.2013 11:27:13 Testo refrigeration technology

More information

REFRIGERANT ON-VEHICLE INSPECTION AC 14

REFRIGERANT ON-VEHICLE INSPECTION AC 14 14 REFRIGERANT ON-VEHICLE INSPECTION 1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET (a) This is a method to specify trouble areas by using a manifold gauge set. Read the manifold gauge pressure

More information

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify your work.

More information

AIR CONDITIONER FLOOR CEILING

AIR CONDITIONER FLOOR CEILING Installation manual ENGLISH AIR CONDITIONER FLOOR CEILING English Indoor unit floor ceiling type FCD / TCD /DCF IT IS MANDATORY TO CUT OFF POWER SUPPLY BEFORE STARTING TO WORK IN THE ELECTRIC CASING BOXES.

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858) User Manual AIR HOG Model: 7303L Vacuum Booster REV. 3/20/18 13655 Stowe Dr. Poway, CA 92064 P: (858) 679-1191 F: (858) 726-6005 INTRODUCTION Dear Customer: Congratulations on the purchase of your new

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS KLDCI12-18RCA - GCLDCI12-18RC INSTALLATION INSTRUCTIONS 1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

More information

Service Parts for RMR Wall-Mount Enclosures

Service Parts for RMR Wall-Mount Enclosures Door Kits for RMR Wall-Mount Enclosures Replacement doors for RMR Wall-Mount Enclosures are removable and can be easily replaced if a door is damaged. Order latch separately. Several options are available:

More information

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM Guangzhou Junliye Import&Export Co., Ltd. AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM OPERATION MANUAL 1. Cautions: Wear the glove and eye protection glass to protect the skin and eyes from

More information

Measurement Solutions for Refrigeration Technology.

Measurement Solutions for Refrigeration Technology. New: now with App and Bluetooth. Measurement Solutions for Refrigeration Technology. Complete solution for the commissioning and maintenance of refrigeration systems and heat pumps. testo 549, testo 550,

More information

mn Dometic KRA Refrigeration Price and Parts Guide

mn Dometic KRA Refrigeration Price and Parts Guide KRA Refrigeration Price and Parts Guide mn Dometic 2175 NW 34th Ave Miami, FL 33142 USA Phone: 786-621-3010 Fax: 786-621-3046 Website: https://yachtaidmarine.com/product-category/marine-air-conditioners/

More information

SERVICE MANUAL FOR MODEL RM-10

SERVICE MANUAL FOR MODEL RM-10 SERVICE MANUAL FOR MODEL RM-10 REQUIRED TOOLS CORDLESS DRILL COPPER CUTTING TUBE 1/2 OPEN WRENCH SOLDERING IRON SCREWDRIVER SET WITH 9/32 SOCKET VISE GRIP PIERCING VALVE PRECISION FLAT BLADE SLOTTED SCREWDRIVER

More information

1. General Description

1. General Description 1. General Description A: SPECIFICATIONS 1. HEATER SYSTEM Heating capacity 2. A/C SYSTEM AUTO A/C MODEL Item Specifications Condition 5.0 kw (4,300 kcal/h, 17,062 BTU/h) or more AC-2 Mode selector switch:

More information

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size). http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL AWR222CLE - AER222SC AWR222CLE - AER222SC3 SPLIT SYSTEM AIR CONDITIONER 0.8180.076.0 03/00 Important! Please Read Before Starting This air conditioning system meets strict safety

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3.   CAUTION www.zenithappliances.com Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3 CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. ONLY FOR AUTHORIZED SERVICE PERSONNEL. CONTENTS

More information

Residential Piping and Long Line Guideline

Residential Piping and Long Line Guideline AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...

More information

Chemistry diaphragm pumps

Chemistry diaphragm pumps Oil-free vacuum for corrosive gases and vapors Chemistry diaphragm pumps Series overview Examples of use Down to 70 Pumping of aggressive gases and vapors For low-boiling solvents Vacuum filtration Down

More information

Order by phone Order on-line Order by fax Website

Order by phone Order on-line  Order by fax Website LABOROTA 4000 Series, Rotary Evaporators The LABOROTA 4000 series comprises the LABOROTA efficient models, the LABOROTA digital models and the LABOROTA control models; all are available with either handlift

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

Tel: Fax: Website:

Tel: Fax: Website: Vacuum Dehydration Oil Purification System(Oil Purifier) The water and particles contamination in lubrication, hydraulic and dielectric oils badly affect the oils performance and threaten system reliability.

More information

Equipment. Application of refrigerants and heat transfer fluids Application of brazing alloys Application of insulation EQUIPMENT

Equipment. Application of refrigerants and heat transfer fluids Application of brazing alloys Application of insulation EQUIPMENT Matériels et outillages Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds Flexibles et raccords Outillages

More information