Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100
|
|
- Lynne Parsons
- 6 years ago
- Views:
Transcription
1 1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination of the warranty. The fl oat-controlled condensate trap is designed for the discharge of condensate from steam, compressed air and pressure gas systems. Any other usage is not permitted. The manufacturer is not liable for damage resulting from any other usage. The user or operator bears the risk in this case. This also applies analogously to incorrect assembly, start-up, use and maintenance. 1.2 Warnings and symbols Personal risk due to escaping operating medium because of pressure, temperature and weight. Failure to comply with these warnings results in the risk of accidents. Follow the instructions in this operating manual. The operator must ensure that this operating manual and, if necessary, other relevant documents are available on site. Only trained or instructed personnel may be assigned to handling this equipment. Any mode of operation that may impair safety must be avoided. 2 General description and usage 2.1 Design of the condensate trap Picture 1: Model WO-1413 Picture 2: Model EF Housing 8 Supporting body assembly 2 Housing gasket 9 Float 3 Housing cover 10 Holding screw for float control assembly 4 Control screw 11 Gasket 5 Housing screws 12 Gasket 6 Screw plug 13 Control screw 7 Float control assembly 14 Gasket Page 1 of 5 10/2017 -Di. Subject to modifi cations
2 2.2 Operation limits of housing material (Design) max. operating pressure (barg) max. operating temperature ( C) -10/ Function limit of control unit (Control units with oval-float) Cross Section max. line pressure in barg 20/ / / Discharge capacity Picture 3 For the cold condensate the discharge capacity is higher because of medium temperature and density. 2.5 Function Due to the gravity the condensate flows downwards to the lowest point, which is the condensate trap housing. In the lowest position of the float the outlet cross-section is close. Rising of the liquid level lifts the float and opens the outlet. Condensate will be discharged through the upturned immersion tube. Decreasing condensate level closes the outlet again. 2.6 Compensation line To get the proper function of the float control assembly in applications of pressure gases, the gases in the condensate trap housing must be led into the gas chamber with the same operating pressure above the condensate trap (pressure compensation). For this purpose the control screw (4) in models 1413 can be replaced by a cutting ring union and a compensating line leading upward can be installed. The pressure compensation for the models 1418 is not strongly recommended. 2.7 Automatic venting In the case of steam applications, automatic venting must be provided (vent jet). 2.8 Gastight under-level float control (only for gas applications) For gas applications, a gastight under-level float control is nearly exclusively used. Consult with Rifox, if necessary. Page 2 of 5
3 3 Assembly The condensate trap has to be screwed into a pipeline between flanges. Remove transport caps from inlet and outlet. Fitting direction: according to Picture 1 and Picture 2. Supporting brackets: The weight of the condensate trap must be taken up by the supporting brackets, which are welded onto the housing. A operation only on the four feets is not allowed. To avoid downtimes, it is recommended to install stop valves with bypass to pipeline, both in front of and behind the condensate trap. For the model WO-1413-(N), remove the transport sefety device (see Picture 4) before start-up and replace it with the control screw provided. For the model EF-1418-(N), remove the fuse wire completely before start up. 4 Start-Up Picture 4 Shut off the float-controlled condensat trap on both sides during the strength tests, because the control unit is not suitable for the design test pressure according to the nameplate. The pressure build-up and heating-up of the housing should not take place abruptly. If leakage is detected after the first inspection, the screws (4 / 5 / 6 / 13) can be fixed under consideration of the given torque moments, as given in Section 6.5. The screws can only be tightened on when the housing is unpressurized and at room temperature. 5 Observation and control The function s failure can be observed either as condensate blockage or as gas/ steam leakage. Condensate blockage can be determined by a): loosen the control screw (4 or 13) for a quarter rotation, while no condensate leakage should occur; and by b): a surface thermometer on the housing for steam applications (if necessary, please consult with Rifox). Gas / steam leakage: can be determined by an ultrasonic measuring device, and for steam applications by a surface thermometer. In case of steam leakage, open the condensate trap according to Section 6.1. Make sure that float can be easily moved. If necessary, disassemble and clean the float control assembly (7). If damages/ wears are detected on parts or on the sealing surface, the complete float control assembly (7) should be replaced. 6 Maintenance / Inspection 6.1 Opening the steam trap and dismantling the float control The steam trap must be depressurized. Shut off the system securely in front of and behind the steam trap. Release any remaining pressure in the housing by loosening the control screw (4 or 13) by only a quarter turn. Dismantle the steam trap from the pipeline system. Loosen the flange connections and lift out of the pipeline carefully and place on the floor. Attention: The condensate trap weights from 250 up to 262 kg depending on the connection sizes. Lifting device is required. Loosen the housing screws (5) evenly crosswise. Put down the housing cover (3). Attention: the housing cover weights about kg. Screws The float control is dismantled with a centering aid that is inserted in the bushing that is provided with 2 slots. By turning counterclockwise (3-4 turns), the bushing is screwed out of the control support body. The control is detached from the seat cone by means of gentle blows with a hammer on the front end of centering aid. Special Float Screw out the bushing completely. Remove float control (7) through the cover opening. Bushing For removal of special float: Loosen, unscrew and remove the screws. See Picture 5. Picture 5 Page 3 of 5
4 6.2 Disassembling, cleaning and assembling the float control (Picture 6) After removing the cotter pin (p), the rotary valve (v) can be simply pulled out to the side. Clean the parts using, for example, benzine. Check the rotary valve (v) for wear along the sealing edge. If wear is detected, the support body (b) together with the rotary valve (v) must be replaced. The thorough leakage test must be carried out by RIFOX. During assembly ensure that the notch in the rotary valve (v) points to the punch mark on the support body (b) and the cotter pin (p) is inserted and secured again carefully. It must be possible to move the float up and down easily by hand. 6.3 Installation of the float control unit and assemble the steam trap b p v Picture 6 The complete float control assembly (7) is inserted into the conical housing seat with the support body. It must be ensured that the tube is positioned vertically downwards. Screw in the bushing into the control support body (b) and tighten with the centering aid described in Section 6.1. Check the housing gasket (2), replace it it is damaged. Put on the housing cover (3). Tighten the housing screws (5) evenly crosswise. Tightening torque according to Section Care and maintenance In the case of a great risk of dirt accumulation, the housing, when it is depressurized, should be rinsed thoroughly from time to time. If necessary, the float control assembly (7) should also be checked according to Section 6.2. The dirt, which has been accumulated in the housing, can be removed away by screwing off the drain plug (6). For special applications, it is advisable to install a separate upstream strainer. The float control assembly (7) usually does not to be special maintained. The maintenance depends primarily on the wear resistance of the valve gasket. See Section 6.1 and Tightening torque Position Part Name Tightening Torque (Nm) 4 Control screw, G½ 70 5 Housing screw 70 6 Screw plug, G¾ Control screw, G¼ 28 Page 4 of 5
5 6.6 Spare parts Only original spare parts can be used. Picture 7: Model WO-1413 Pos. Bennenung Material 1 Housing 16Mo3 2 Housing gasket 3 Housing cover 16Mo3 4 Control screw EF: G 1/4 (BSP) or WO: G 1/2 (BSP)] 5 Housing screws 21CrMoV5-7 / 24CrMo5 / 6 Screw plug DIN A4 - G 3/4 (BSP) 7 Float control assembly stainless steel 8 Supporting body assembly stainless steel 9 Float 10 Bush 11 Gasket 12 Gasket G 1/4 (BSP) or G 1/2 (BSP)] 13 Control screw G 1/4 (BSP) or G 1/2 (BSP)] 14 Gasket 21CrMoV5-7 / 24CrMo5 / Picture 8: Model EF Conformity assessment The pressure equipment described is a pressure-keeping component in accordance with the Pressure Vessel Directive 2014/68/EU. DN50 / DN80 / DN100: Conformity verifi ed through the identifying mark: CE A detailed declaration of conformity assessment according to PED is available as separate document. Please request if necessary, if not attached. Model 1413/1418 made of 16Mo3 is not applicable for media of fl uid group 1. Page 5 of 5 10/2017 -Di. Subject to modifi cations
Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use
1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationModel: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40
1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically
More informationModel: 1100 Float-Controlled Condensate Trap, PN 25
1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationGESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45
GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED
More informationSteam Trap BK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...
More informationINSTALLATION, OPERATION
OM No. E-ER25-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ER 25 SERIES MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku
More informationOperating and installation instructions
Steam traps for quick assembly/disassembly CONA Universal/ CONA Connector ANSI300 - with Universal-Flange 2 x 3/8 UNC thread (BR 604) ANSI300 - with Universal-Flange 2 x 3/8 UNC thread (BR 622) ANSI300
More informationBK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-07 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety notes...4
More informationINSTALLATION, OPERATION
OM No. E-ES8N-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ES8N MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku Osaka
More informationGESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50
GESTRA Steam Systems BK 15 Installation Instructions 810682-02 Steam Trap BK 15, DN 40-50 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure
More informationMK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2
GESTRA Steam Systems MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2 Installation Instructions 810348-07 Steam Traps MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 Contents Important Notes Page Usage for the intended purpose...4
More informationAIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions
AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product
More informationSuperKlean Washdown Products
February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT
More informationInstallation & Operation Instructions Nr _EN_Manual
Installation & Operation Instructions Nr. 100087_EN_Manual Product: Fog / Jet Monitor (FJM) Manual and Manual with Foam Inductor Versions Model Types: FJM-80, FJM-100, FJM-150 FJM-80S, FJM-100S, FJM-150S
More informationICS Float and Thermostatic Steam Trap Installation and Operation Manual
ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.
More informationINSTALLATION, OPERATION
OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this
More informationTechnical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT
Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT
More informationSteam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat
s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationInstallation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63
Installation and Maintenance Manual Forbes Marshall Tracer Line Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationTHERMODYNAMIC STEAM TRAP
THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationSMK 22 SMK SMK SMK 22-82
GESTRA Steam Systems SMK 22 SMK 22-51 SMK 22-81 SMK 22-82 EN English Installation Instructions 810481-04 Steam Traps SMK 22, SMK 22-51, SMK 22-81, SMK 22-82 1 Contents Title Page Title page...1 Inhalt
More informationLevel Electrode NRG Original Installation Instructions English
Level Electrode NRG 16-36 EN English Original Installation Instructions 819257-01 Contents Contents Page Important notes Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationBK 46. Installation Instructions Steam Trap BK 46
BK 46 Installation Instructions 810645-00 Steam Trap BK 46 1 Capacity Chart 2 1 Fig. 1 1 2 Max. discharge capacity of hot condensate Max. discharge capacity of cold condensate 2 Design A B C D D E E1 F
More informationLevel Electrode NRG NRG Original Installation Instructions English
Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and
More informationDomestic Hot Water Tank
Installation and Operating Manual Domestic Hot Water Tank WWKS 300 WWKS 500 EN For the professionals Read carefully before installation Table of Contents 1 Use............................. 3 2 Safety Instructions
More informationGESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME
GESTRA Steam Systems BK 37 BK 28 BK 29 Installation Instructions 818689-00 Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME Contents Important Notes Page Usage for the intended purpose...4
More information13-1. Temperature Regulator
-1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details
More informationTRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57
GESTRA GESTRA Steam Systems TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57 EN English Installation & Operating Instructions 810428-05 Temperature Sensor TRG 5-53, TRG 5-54, TRG 5-55, TRG 5-57 1 Contents Application
More informationInstallation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers
Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)
More informationHodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd
1 MJC Mini Cartridge Filters Owners Manual TSOM 556 Date of Issue: 13.07.04 Orgreave Drive, Sheffield South Yorkshire. S13 9NR Tel:0114 254 0600 Fax: 0114 2540250 Email:sales@hodgeclemco.co.uk www.hodgeclemco.co.uk
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.
INSTRUCTION MANUAL Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, Japan Tel: [81]-(0)79-422-1122
More informationTemperature Sensor TRG Original Installation Instructions English
Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer
INSTRUCTION MANUAL Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES SS3N SS3V / SS5N SS5V / SS5NH SS5VH Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo
More informationMK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A
MK 45 A Stainless Steel Design Installation Instructions 810603-00 Steam Trap MK 45 A 1 Capacity Chart 1 2 3 4 Capacity 1 2 3 4 Max. flowrate of cold condensate for MK 45 A-2. Max. flowrate of cold condensate
More informationInverted Bucket Steam Traps
INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-2-00-US December 201 Inverted Bucket Steam Traps Safety Information Safe operation of these products can only be guaranteed if they are properly installed,
More informationVacuum Switch, Differential Pressure Adapter, Switching Amplifier
Operating Manual Incl. EU Declaration of Conformity Vacuum Switch, Differential Pressure Adapter, Switching Amplifier VSC150, SV tina42e1-b (2017-03) 1 Product Identification In all communications with
More informationF-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual
F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual 008094 All fire extinguishers should be installed, inspected and maintained in accordance with
More informationPump assembly Instruction manual
Instruction manual EN Version 2.0 /Release 06/2012 Table of content 1 Key background information...3 1.1 Limitation of liability...3 1.2 Responsibilities of the operator...3 1.3 Documentation...3 1.3.1
More informationS and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions
0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning
More informationASPIRE Laboratory Aspirator
ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More informationInstallation and instruction manual SOLAR STATION
INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Installation and instruction manual SOLAR STATION SST 25-1E / SST25-2E EN April 2015 1 Table of contents Usage 3 Warranty 3 Safety instructions and symbol
More informationOperating manual for Steam Injectors / Mixing Nozzles
special design apparatus construction Operating manual for Steam Injectors / Mixing Nozzles Pipeline and Vessel Mounting Type RKE, RFF, RLF, IFF, ILF, IGE, IFA, IFM Content Page 1. General safety instructions
More informationOperating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationInstallation Instructions
Installation Instructions THERMAL EXPANSION VALVE (TXV) KIT FOR HEAT PUMP AND AIR CONDITIONING SAFETY INFORMATION IMPORTANT: Please read all instructions before servicing this equipment. Pay attention
More informationOperation, Maintenance and Installation Manual
Manual No. FS-OM1-5 1-16 in. FloodSafe Inflow Preventer Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 CONSTRUCTION...
More informationAkva Lux VX District heating substation for indirect heating and domestic hot water systems
Akva Lux VX District heating substation for indirect heating and domestic hot water systems Akva Lux VX Table of Contents Akva Lux VX... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport
More informationMODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS
MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications
More informationopening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)
Issue Date: 4/06 GESTRA Steam Systems Thermostatic Steam Traps MK 45-, MK 45-2 PN 40, DN 5, 20, 25 (½", ¾", ") Product Range A MK 45- MK 45-2 Description Thermostatic steam trap with membrane regulator.
More informationPT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.
PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC
More informationGRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS
More informationGEM TRAP FITTING & MAINTENANCE INSTRUCTIONS
GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS IMPORTANT Please read these instructions before fitting any traps. The following pages describe how each type of GEM Trap should be installed. If you are unsure
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationTITAN FLOW CONTROL, INC.
PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Suction Diffusers. To ensure efficient and safe operation
More informationIndustrial Filters Replacement Procedure
FGD FGE FGET FGG Vessel Series Vessel Series Vessel Series Vessel Series p. 537 p. 538 p. 540 p. 543 FGA FGB FGC FGF Vessel Series Vessel Series Vessel Series Bag Filter p. 545 p. 549 p. 553 p. 555 FGH
More informationModel T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!
Application Legend thermostatic mixing valves are designed for applications requiring temperature control, scald prevention and reduction of thermal shock in domestic potable water distribution (Model
More information1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material
1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationOperating instructions
BA60500GB.docx, Operating instructions -Translation of the original- Dirt Collecting Filter DIN m/m M&S Article No. 60500 M & S Armaturen GmbH Industriestraße 24-26 - 26446 Friedeburg - Germany fon +49(0)4465
More informationDRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Manufacturers of... Quality Products since 1866 95 N. Oak St. Kendallville, IN 46755 1-800-345-9422 DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST FW0771 0116 Supersedes 0415 MODEL: DATE
More informationHKF 8180 Operating instructions
Operating instructions EN Version 1.0en /Edition 05/2013 Contents 1 Important basic information... 3 1.1 Limitation of liability... 3 1.2 Operator's responsibilities... 3 1.3 Documentation... 3 1.3.1 Content
More information"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16
Webster Pumps "S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING Webster PUMPS or HAYWARD VALVES,
More information4 route 147, C.P.33 Coaticook, Qc J1A 2S8
4 route 147, C.P.33 Coaticook, Qc J1A 2S8 TABLE OF CONTENTS INSTALLATION Nozzles p.3 Clearance for dismantling p.4 Foundations p.4 Foundation bolts p.5 Leveling p.5 Bolted joints p.5 Recommended bolt tightening
More informationInstruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity
- Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity 100 PPD (2 kg/h) Chlorine or Sulfur Dioxide 250 & 500 PPD (5 & 10 kg/h) Chlorine or Sulfur Dioxide Anti-Siphon Ejector
More informationInstructions for Installation, Operation, Care and Maintenance
Bulletin 422 Model E Alarm Check Valve Bulletin 422 Instructions for Installation, Operation, Care and Maintenance DN100, DN150, DN200 SIZE Model E with E2 Euro Trim The Reliable Automatic Sprinkler Co.,
More informationOriginal instructions. Operation Manual & Cautions
Original instructions Operation Manual & Cautions Thank you for purchasing the Mistresa from Showa Denki. This manual explains the specifications for the [Mistresa units from CRN Series]. Please read the
More informationInstallation & Operating Instructions
GESTRA Steam Systems NRG 16-50S EN English Installation & Operating Instructions 819013-01 Level Electrode NRG 16-50S 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety
More informationHELMUT KÄMPKEN GMBH OPERATING MANUAL
OPERATING MANUAL Operating manual for Steam Injectors / Mixing Nozzles PRODUCT DESCRIPTION Content: Page 1. Product Description 2 1.1 Prescribed use 2 1.2 Structure 3 1.3 Description of functions 4 1.4
More informationHW 22 District heating substation for indirect heating and domestic hot water systems
HW 22 District heating substation for indirect heating and domestic hot water systems HW 22 Table of contents HW 22... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport and storage...
More informationOperating Instructions. Rotating Vacuum Filter Type VRF
Operating Instructions Rotating Vacuum Filter Type VRF GB Rotating Vacuum Filter Type VRF Table of Contents 1 Description of machine and functions... 5 2 Danger and safety instructions... 6 2.1 General
More informationMechanical seals external, single or double, to DIN EN 12756
INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference. QuickTrap FX1 Trap Unit X1. Manufacturer
INSTRUCTION MANUAL Keep this manual in a safe place for future reference UNIVERSAL TEMPERATURE CONTROL STEAM TRAP FX1 QuickTrap FX1 Trap Unit X1 Option ( BD2 ) Manufacturer 881 Nagasuna, Noguchi, Kakogawa,
More informationDEVIATING VALVES ART K063
FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationINSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS
INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.
More informationInstallation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator
Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator 2008 Groth Corporation IOM-8331 Ref. ID: 95566 TABLE OF CONTENTS: GENERAL SAFETY INSTRUCTIONS 3 SAFETY WARNINGS 3 INSPECTION
More informationSTEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.
STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY Information Reviewed and Reaffirmed August 196 No. 1664 11111111111134 areillin1111111 1 11111111 1 1[1 11 nin FOREST
More informationTroubleshooting the MPH 24FP Series Pedestal Hydrant
MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi
More informationInstallation, Operation & Maintenance Instructions
Installation, Operation & Maintenance Instructions 313 OVERFLOW TRAP TALE OF CONTENTS Overview... Cover General Information... Cover Installation... 4 Operation... 4 Maintenance... 4 Float all Level Test
More informationKITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE
KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5
More informationBetriebsanleitung Operating Instructions
Betriebsanleitung Operating Instructions Oil mist filter idealvac.com (505)872-0037 idealvac.com ONF 16 PK 0213 BE/G (0811) ONF 25/25L/25XL Table of contents Table of contents 1 About this manual......................................
More informationInstallation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010
Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail:
More informationInstallation and operating instructions. DK energy storage and DK energy buffer
Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The
More informationINSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !
Condensate Return Systems General Installation, Operation, & Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. SAFETY INSTRUCTIONS This safety alert symbol will be used in this
More informationOWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE
FOAM FIRE EXTINGUISHERS MODEL 254-6 LITER AFFF FOAM WITH SPRAY NOZZLE Model 250 2 ½ GAL.LON AFFF FOAM WITH ASPIRATED NOZZLE MODEL 252 2 ½ GAL.LON FFFP (ALCOHOL RESISTANT) FOAM WITH ASPIRATED NOZZLE OWNER'S
More informationOPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F
OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationInstallation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers
OM010 Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers The operating and maintenance instructions contained within this package are for ThermaFlex gasketed
More informationSeries B Inverted Bucket Steam Traps
Installation & Maintenance Instructions H-208(E) eries Inverted ucket team Traps eries 0 eries 1 eries 2 eries 3 eries 4 eries 6 WARNING CAUTION! WARNING efore using product, read and understand instructions.
More informationLP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions
4024750/9 IM-P402-44 AB Issue 9 LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Wiring 5
More information1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450
1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside
More informationREVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP
REVE INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation
More informationFT14 Ball Float Steam Trap (Screwed)
Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals
More informationTHERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS
Page 1 of 10 THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS Purpose of Manual The purpose of this manual is to provide operating, servicing and repair instructions for the Summit standard models ThermaPhase
More informationInstallation and Maintenance Manual
Installation and Maintenance Manual Forbes Marshall Thermodynamic Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1. Important Safety Notes...1
More informationImpeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5
GRUNDFOS CR Series Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 5 Grundfos Pumps Corporation 17100 W. 118th Terrace Olathe, Kansas 66062 Telephone: 91.227.00 Fax: 91.227.500 www.grundfos.com
More information