208 For more information visit our website at
|
|
- Alban Underwood
- 6 years ago
- Views:
Transcription
1 REFRIGERANTS REFRIGERANT Realcold supply refrigerants sourced from A-Gas for all applications. All refrigerant products are quality assured under AHRI 700 International Refrigerant Standards. We offer interim HCFC and long-term HFC refrigerants as well as non-fluorinated refrigerants such as ammonia. R404A R22 L2020S 10kg P.O.A L2020M 16kg P.O.A R134A L2020L 50kg P.O.A L2000S 12kg P.O.A L2000M 22kg P.O.A L2000L 65kg P.O.A R407C (R22 Replacment) L2010S 12kg P.O.A L2010M 22kg P.O.A L2010L 65kg P.O.A L2030S 11kg P.O.A L2030M 20kg P.O.A L2030L 65kg P.O.A R507 L2060S 10kg P.O.A L2060M 16kg P.O.A L2060L 55kg P.O.A R437A (R12 Drop In) L2070S 12kg P.O.A L2070M 22kg P.O.A R410A - 65kg P.O.A R438A (R22 Drop In) L2090S 12kg P.O.A L2090M 20kg P.O.A L2090L 65kg P.O.A L2050S 10kg P.O.A L2050M 18kg P.O.A L2050L 60kg P.O.A R407F LR407F-N 11kg P.O.A LR407F-P 20KG P.O.A LR407F-R 55KG P.O.A R717 (Ammonia) L5... Per kg P.O.A Available in 34kg, 56kg, 230kg & 1000kg. Realcold will only supply refrigerant to appropriately trained and licenced account holders. All refrigerant products are quality assured under AHRI 700 International Refrigerant Standards. Refrigerant is available in pre-filled and leak tested cylinders equipped with non-return check valves. All cylinders supplied by Realcold are compliant with Australian standards AS Refrigerant cylinders returned within a month will not attract any service fee. Realcold/A-Gas cylinders have unique serial numbers for ease of tracking and reporting. For full terms and conditions relating to cylinders, please refer to Realcold's Term's & Conditions of Sale. PLEASE CONTACT REALCOLD IF YOU REQUIRE FURTHER INFORMATION OR AVAILABILITY OF OTHER REFRIGERANTS 208 For more information visit our website at
2 RECLAIM, PUMPDOWN & NITROGEN RECLAIM CYLINDERS L6000S Reclaim cylinders are provided to enable refrigeration 8kg P.O.A L6000M contractors to reclaim unusable refrigerant for return to Realcold for a credit and subsequent return to 16Kg P.O.A L6000L Refrigerant Reclaim Australia 52Kg P.O.A Returning reclaim refrigerant to Realcold ensures safe and environmentally friendly disposal in compliance with legislation, and attracts a payment as directed by Refrigerant Reclaim Australia (RRA). Reclaim cylinders are suitable for all refrigerants including R410A. PUMPDOWN CYLINDERS (Recovery) L4010M Pumpdown cylinders are provided to enable refrigeration contractors to recover refrigerant into a 22 Kg P.O.A L4010L guaranteed clean cylinder for reuse after repairs are completed 65 Kg P.O.A All refrigerant cylinders are clean and dehydrated to maintain purity of recovered refrigerant. Pumpdown cylinders are suitable for all refrigerants including R410A. DRY NITROGEN L3000D 10Ltr (1.8m 3 ) High purity dry nitrogen D P.O.A L3000E 20Ltr (3.6m 3 ) High purity dry nitrogen E P.O.A NITROGEN REGULATORS 40 Micron sintered filters in inlet Ports 3,000 KPa maximum outlet pressure 7/16" SAE or 1/4" Flare outlet fitting Unique spherical valve system Low friction seat design Manufactured to AS 4267 T4051 features Tee-Bar control with needle roller thrust bearing for accurate settings and 3500kpa MOP T4050 Nitrogen Regulator T4051 Nitrogen Regulator - with Tee-bar handle For more information visit our website at
3 REFRIGERATION OILS MINERAL OIL TYPE APPLICATION N0531 Suniso 3GS 4 Ltr Low / Med Temp N0535 Suniso 3GS 20 Ltr N0541 Suniso 4GS 4 Ltr Med / High Temp N0545 Suniso 4GS 20 Ltr POLYOLESTER OIL TYPE APPLICATION N0585A Suniso 32S 1 Ltr N0585 Suniso 32S Low / Med Temp 4 Ltr N0586 Suniso 32S 20 Ltr N0587A Suniso T68 1 Ltr N0587 Suniso T68 Med / High Temp 4 Ltr N0588 Suniso T68 20 Ltr SCREW COMPRESSOR OIL TYPE DRUM C5864 Solest 170 Screw Compressor Oil 19 Ltr AMMONIA OIL TYPE DRUM N0592 Suniso 4SA 20 Ltr Ammonia Oil N0593 Suniso 4SA 205 Ltr 2, TRANSPORT OIL TYPE N0594 Solest 35 5 Ltr Transport Oil N0595 Solest Ltr 1, N0596 Solest CP Ltr Transport Oil N0597 Solest CP Ltr VACUUM PUMP LUBRICANTS TYPE N0105 Vac 1 Ltr Vacuum Pump Oil N0106 Vac 4 Ltr YELLOW JACKET SERVICE OIL PUMP T Max-Flow Combination Service Oil Pump Easily adds or removes oil for recovery or conversion at 78ml per stroke - Pumps against pressure to 1380kpa 210 For more information visit our website at
4 SERVICE AIDS SUPERSEAL KITS G KIT BRAND APPLICATION GUIDE ACR Sealant Kit.07 to 5kw G KIT HVACR Sealant Kit 5 to 17 kw G0692A 948KIT Commercial Sealant Kit 17kw plus G KIT Super Seal Auto Air Conditioning Auto Air G KIT Dry R - System Drying Agent G0692B 971KIT Total 1 - c/w UV Dye & Drying Agent.07 to 5kw G0692C 972KIT Total 2 - c/w UV Dye & Drying Agent 5 to 17kw ACID TEST KITS & NEUTRALISERS COIL CLEANERS BRAND PACK N1007 COBRA Cobra Coil Cleaner No Rinse (Aerosol) 425g Minehan N1007A COBRA Green Cobra Coil Cleaner No Rinsing 5 Ltr N0658 AC Momar A/C Foaming coil Cleaner (Aerosol) 510g N0895 COILOX Coilox Coil Cleaner 5 Ltr Hydrochem N0896 COILKLEEN Acidic Coil Cleaner 5 Ltr N0899 4X BRAND PACK SP4000 TA1 Sporlan Test-All TA1 Acid Test Kit - POE & Mineral N Acid-Away Acid Neutraliser - Mineral 118ml Rectorseal N Acid-Away Acid Neutraliser - POE 118ml Coil Cleaner Concentrate 1 Ltr N0900 AK-4 Care Alkaline Coil & Filter Cleaner 4 Ltr N0902 AK-1 Sterile Care Alkaline Coil & Filter Cleaner 1 Ltr N0904 AB-4 Acidic Coil Cleaner 4 Ltr N0906 AB-1 Acidic Coil Cleaner 1 Ltr ICE MACHINE CLEANERS BRAND PACK N0912 IMC1 Ice Machine Cleaner 1 Ltr Sterile Care N0914 IMC4 Ice Machine Cleaner 4 Ltr LEAK DETECTION BRAND PACK T0440 RT100S Big Blue c/w Spray Applicator 985ml Refrig Tech T0442 RT100G Big Blue - Refill 4 Ltr N0897 Bubble-up Hydrochem Bubble-up c/w Spray Applicator 500ml N0786 Visu-Glow LA-CO Visu-Glow - Fluorescent c/w Applicator 236ml Please contact Realcold for more information on the above products including Material Safety Data Sheets. 211 For more information visit our website at
5 SERVICE AIDS AIR FRESHENERS N0908 FAS-1 PACK Fresh Air Sponge - Return Air 500ml N0910 FAS-4 Sterile Care Fresh Air Sponge - Return Air 2 Ltr N0915 CA1 Clean Air Freshener (Aerosol) 250g N1016 Fiesta Minehan Orange Twist Jelled Deodorant (Aerosol) 425g DRAIN PAN TREATMENT N1002 DRAIN-O-FLUSH BRAND PACK Liquid Drain Solvent 1 Ltr N1008 CHARGE Minehan Pressure Spray Drain Solvent (Aerosol) 400g N1005 CHEM TABS Antibacterial Drain Pan Tablets 12 Tablets CORROSION PROTECTION BRAND PACK N1001 MR MECHANIC Lube Penetrating Spray (Aerosol) 400g Minehan N1006 QUIK ZINC Cold Gal Zinc Treatment Paint (Aerosol) 400g N0784 FIN SAVER Hydrochem Finned Coil Anti Corrosion Spray 510g FLUSHING AGENTS BRAZING COOLING AGENTS BRAND PACK N0781 COOL GEL Heat Barrier Spray for Brazing 473ml LA-CO N0782 COOL GEL Heat Barrier Spray for Brazing 946ml HAND CLEANER BRAND PACK BRAND PACK T6169A PRO FLUSH System Flushing Agent 5 Ltr CPS T6169B PRO FLUSH System Flushing Agent 20 Ltr EVAPORATIVE COOLING TREATMENT BRAND PACK N0928 EDC-M Sterile Care Mini Dose Cartridge N0898 BIO-SUB Hydrochem Slow Release Tablets (Disolve in container) HEAT TRANSFER PASTE BRAND PACK N Bostik Heat Transfer Paste - Thermal Contact 460ml N1009 HAND SCRUB Minehan Waterless Industrial Hand Cleaner Tube 650ml For more information visit our website at
Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration
More informationAccumulators - Suction Line
ACCUMULATORS Accumulators - Suction Line kw Cap at Evap. Temp. -6 C Size Connection R22 R404A / R507C F0804 1/2" ODS Vertical 4.6 4.8 F0805 5/8" ODS Vertical 6.9 7.2 F0806 3/4" ODS Vertical 9.2 9.6 F0807
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationFSW SECTION. Product guide. Refrigerant, Oils & Cleaning Chemicals M SECTION For more information visit
FSW Product guide M SECTION Refrigerant, Oils & Cleaning Chemicals 213 Refrigerant For Conditions of Cylinder loan please see the Info Section C.O.S.H.H. Regulations apply, please ask for a copy. HFC Grade
More informationEXHIBIT G REFRIGERANT MANAGEMENT POLICY
EXHIBIT G REFRIGERANT MANAGEMENT POLICY Table of Contents Refrigerant Manager... 3 Basic Refrigerant Management Policy... 3 Policy... 4 Tenant responsibility... 5 Contractor responsibility... 6 Sample
More informationNU-CALGON CHEMICAL PRODUCTS
INDEX COIL CLEANERS CALCLEAN... 11-3 NU-BRITE... 11-3 EVAP FOAM NO RINSE... 11-4 EVAP POW'R-C... 11-4 NU-BLAST CONDENSER... 11-4 SELECTION GUIDE... 11-2 11-3 SPECIAL HD CALCLEAN... 11-4 GAS LEAK DETECTORS
More informationKITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M
2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR
More informationRefrigeration Supplies
Section 11 Refrigeration Supplies INDEX Refrigerant.. 11-2 R-410A. 11-2 HOT-SHOT by ICOR.. 11-2 NU-22b by ICOR. 11-2 Recovery Service 11-2 Recovery Tanks. 11-2 608 Certification. 11-2 Supplies Filter Driers.
More informationFrigi Tech International, Inc Prairie Wind Lane,. Houston, Texas T: F:
Education at your fingertips There is the misconception that t an air conditioner blows cold air when actually it removes the heat from the conditioned space. Let s start trtwithwhtwe re what we re all
More informationCHEMICALS OILS & SUPPLIES MAINTAIN PEAK EFFICIENCY FOR ALL EQUIPMENT QUALITY PERFORMANCE EQUIPMENT & TECHNICIAN SAFE* CLEAR, SIMPLE EASY
CHEMICALS OILS & SUPPLIES MAINTAIN PEAK EFFICIENCY FOR ALL EQUIPMENT QUALITY PERFORMANCE EQUIPMENT & TECHNICIAN SAFE* CLEAR, SIMPLE EASY *When used by HVAC/R professional as directed MAINTAIN PEAK EFFICIENCY
More informationReplaceable Filter-Drier Cores/Blocks
Replaceable Filter-Drier Cores/Blocks Alco Filter-Drier Blocks and Filter Cores Alco suction fi lter cores (F-48) and desiccant blocks (D-48, UK-48, W-48, H-100) fi t most competitive shell type fi lter-driers.
More informationRecommendations Climalife
cleaning Recommendations Climalife External cleaning Filters Ventilation ducts Evaporator ribs Drain pans Condensers / Evaporators / Hoods Grease Condensers Odours Surfaces Internal cleaning Internal cleaning
More informationAir Conditioning Operation and Troubleshooting Matt Dunham
Air Conditioning Operation and Troubleshooting Matt Dunham Major Components (10 Minutes) Compressor heart of the system, causes refrigerant to flow by increasing the pressure of the refrigerant Metering
More informationAC1234 PRODUCT RANGE.
AC1234 PRODUCT RANGE THE REFERENCE POINT FOR THE MAINTENANCE OF THE R-1234YF A/C SYSTEMS www.ac1234yf.com AC1234-8, AC1234-7 AND AC1X34-7 AC1234-8 and AC1234-7 are service stations which perform maintenance
More informationSHOWCASE. Spring Maintenance FREE PRODUCTS 2% OFF $1,500 WITH CASE QTY PURCHASE OF SELECT ITEMS SEE INSIDE COVER FOR DETAILS ANY ORDER OF OR MORE!
Spring Maintenance SHOWCASE NO MINIMUM ORDER EFFECTIVE 3/15-5/31 2% OFF ANY ORDER OF $1,500 OR MORE! WITH CASE QTY PURCHASE FREE PRODUCTS OF SELECT ITEMS SEE INSIDE COVER FOR DETAILS MOTORS 2 CHEMICALS
More informationSOLUTIONS TO KEEP IT COOL
SOLUTIONS TO KEEP IT COOL Cool Air Products has the safest, most innovative, smartest solutions in the market. Cool Air Products was founded with the concept of manufacturing revolutionary products that
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE
More informationReference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.
GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant
More informationPATENTED PATENT PENDING PATENTED PATENTED
2 3 Our services Saniflux Hybrid Diag Nitro Hermetic PATENTED PATENT PENDING PATENTED PATENTED The first A/C system and passenger compartment air purification system combined with a charging station. 2
More information10/4/2013. The Changing State of Refrigerants
10/4/2013 The Changing State of Refrigerants Refrigerant Chemistry CFC = Chlorofluorocarbon Rapid phase-out Stopped U.S. production in 1996 R-11, R-12, R-113, R-114, R-500, R-502 HCFC = Hydrochlorofluorocarbon
More informationSHOWCASE FREE 2ND YEAR WARRANTY WITH INSTALL OF CORESENSE ON SELECT COPELAND COMPRESSORS 2% OFF $1,500 ANY ORDER OF. OR MORE! Spring Maintenance
2% OFF ANY ORDER OF $1,500 OR MORE! Spring Maintenance SHOWCASE NO MINIMUM ORDER REQUIRED VALID 3/6/17-5/31/17 FREE 2ND YEAR WARRANTY WITH INSTALL OF CORESENSE ON SELECT COPELAND COMPRESSORS SEE INSIDE
More informationINSTRUCTIONS! DO NOT DISCARD!
INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationThe complete approach to the care and management of A/C & refrigeration systems
The complete approach to the care and management of A/C & refrigeration systems Testing oil with the Phase III Refrigeration Oil Acid Test Kit Flushing with OEM endorsed R x 11-flush Acid removal with
More informationAIR CONDITIONNING 95 CODE 002
CODE 002 AIR CONDITIONNING 95 Cool-Tech Refrigerant Recovery/Recycling Unit Model 34788 It recovers, recycles, evacuates, leak tests, and recharges R-134a quickly and accurately. Fully automatic function
More informationGary Parker Refrigerants Product Manager
Gary Parker Refrigerants Product Manager Refrigerant History Status of the HCFC ( R22) Phase out Ozone Friendly Alternatives Choosing the Best Retrofit Solution Lubricants and how they impact performance
More informationGary Parker Refrigerants Product Manager
Gary Parker Refrigerants Product Manager Refrigerant f i t History Status of the HCFC ( R22) Phase out Ozone Friendly Alternativesti Choosing the Best Retrofit Solution Lubricants and how they impact performance
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationThe Changing State of Refrigerants. Gary Parker Refrigerants Product Manager
The Changing State of Refrigerants Gary Parker Refrigerants Product Manager The Changing State of Refrigerants Acronyms you may want to know CARB California Air Resources Board GWP Global Warming Potential
More informationAIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw
PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationNZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a
Page 1 of 5 Title Convert an automotive air conditioning system from R-12 to R-134a Level 3 Credits 2 Purpose This unit standard is for people in the automotive repair industry. People credited with this
More informationINSTALLATION INSTRUCTIONS
,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE
More informationUse of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning
Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning This initiative was developed by: Content and guidance kindly provided by the following organisations: Cool Drive CPS Asia Pacific
More informationChapter 2. Alternatives to HCFCs and their Characteristics
Alternatives to HCFCs and their Characteristics Refrigerant - General Chemical used in a cooling system, such as an air conditioner or refrigerator, as the heat carrier which changes from vapour to liquid
More informationTechnical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:
Technical Review of a Remote Condenser Cuber with Enhanced Refrigeration and Water Systems using CM 3 Technology models included are: CME1356 shown on BH900 CME456, CME1056, CME1356, CME1656 and CME2006
More informationCOMPONENTS SOLUTIONS MAINTENANCE PRODUCTS. for refrigeration and air conditioning systems
REFRIGERATION & CLIMATE COMPONENTS SOLUTIONS MAINTENANCE PRODUCTS for refrigeration and air conditioning systems EXTERNAL CLEANING A regular maintenance in order to increase the energy performance of the
More informationCHEMICALS, SUPPLIES & OILS
CHEMICALS, SUPPLIES & OILS Maintain Peak Efficiency For All Equipment QUALITY EQUIPMENT & TECHNICIAN SAFE * PERFORMANCE CLEAR - SIMPLE EASY * Safe when used by a trained HVAC/R professional as directed.
More informationBAC 4000a BAC 5000yf
AC Service Units BAC 4000a BAC 5000yf AC Service Units Recommended by Volvo Cars Fully-automatic, high capacity and comfortable Maximum safety Easy to use BAC 4000a Maximum precision easy operation. The
More informationTOTALINE CHEMICAL CATALOG
TOTALINE CHEMICAL CATALOG visit www.totaline.com TOTALINE CHEMICALS Trust a leader in HVAC coil cleaning and get the job done right, the first time! Totaline offers you a complete line of Chemicals for
More informationTOTALINE CHEMICAL CATALOG
TOTALINE CHEMICAL CATALOG visit www.totaline.com TOTALINE CHEMICALS Trust a leader in HVAC coil cleaning and get the job done right, the first time! Totaline offers you a complete line of Chemicals for
More informationUser manual Flushing device VAS 6337/1a
User manual Flushing device VAS 6337/1a 2 Content Safety warnings 3 Flushing with R134a refrigerant 4 1.0 Preparing the Vehicle AC System 4 1.1 Connecting the recovery recharge Unit 6 1.2 Flush procedure
More informationREFRIGERANT REFERENCE GUIDE
United States National Refrigerats, Inc. 1140 Roosevelt Boulevard Philadelphia, PA 19154 215-698-6620 800-262-0012 Fax: 215-698-7466 United Kingdom National Refrigerants of America Ltd. 4 Watling Close
More informationRefrigerant changeover guidelines
Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/F, R-448A or R-449A for medium and low temperature applications HCFC R-22 to HFC R-407C for high, medium and low temperature applications HCFC
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationThe natural solution for domestic refrigeration
The natural solution for domestic refrigeration 1300 492 445 info@hychill.com.au Minus 10 is a high-purity R600a (isobutane), the dominant single-ingredient refrigerant used in state-of-the-art light commercial
More information4/19/2013. The Changing State of Refrigerants
4/19/2013 The Changing State of Refrigerants Refrigerant Chemistry CFC = Chlorofluorocarbon Rapid phase-out Stopped U.S. production in 1996 R-11, R-12, R-113, R-114, R-500, R-502 HCFC = Hydrochlorofluorocarbon
More information6 Months Worklights (non-led), Blue Lights
INDEX SUPER SEAL TOTAL & ADVANCED...4 & 5 SUPER SEAL SURE SHOT...6 SUPER SEAL PREMIUM - AUTOMOTIVE...7 SUPER CHANGE...8 DRY R...9 FLASH, UV KITS & INSPECTION LIGHTS...10 & 11 LED WORKLIGHTS...12 & 13 SERVICE
More information14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.
HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant
More informationFilter Driers with Replaceable Core
STANDARD Filter Driers with Replaceable Core The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter
More informationRefrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies, Inc. does not advocate
More informationPATENTED PATENT PENDING PATENTED PATENTED
2 3 Our services Saniflux Hybrid Diag Nitro Hermetic PATENT PENDING The first A/C system and passenger compartment air purification system combined with a charging station. 2 services in a single station!
More informationSERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11
SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume
More informationChemicals. Cement (For PVC, ABS & CPVC) G20. For Water Treatment Chemicals See Water Treatment And Purification Chemicals Section 27/05/16
Cement (For PVC, ABS & CPVC) G20 All purpose cement for PVC, ABS, CPVC pipe and fittings up to 6" in diameter 2 hour cure time at 16C (60F) before pressure testing (up to 180 psi). Longer cure times may
More informationValley View Window Cleaner. Jungle Jake. Cleaner/Degreaser. Jungle Jake. Ready-To-Use. Jungle Jake Cleaner/Degreaser
PRODUCT NUMBER CONVERSION CHART To use this chart, simply look up the product and the old Stearns Packaging Product Number is in the top oval and you ll match the new Product Number in the lower oval.
More informationNu-Brite Same popular Nu-Brite Powerful high foaming action lifts out dirt and grime while brightening coils Excellent & powerful cleaner that is espe
Aerosols Nu-Brite Same popular Nu-Brite Powerful high foaming action lifts out dirt and grime while brightening coils Excellent & powerful cleaner that is especially adapted for kitchen degreasing Outdoor
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Series Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life,
More information410AREFRIGERANTTRANSITIONGUIDE
Contactyourlocal ValueFirstrepresenta ve byvisi ng www.valuefirstonline.com/local 410AREFRIGERANTTRANSITIONGUIDE Replace-Retrofit-Repair (seenextpagefordetails) REPLACE OR REPAIR? OUR HVAC EVALUATION HELPS
More informationScroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C
Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C McQuay International (A Member of the DAIKIN Group) Hydrofluorocarbon (HFC) refrigerants are critical to the safe and cost-effective phase-out
More informationPRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications
DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL
More informationRefrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW
Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as
More informationDehydrators and Filters
Dehydrators and Filters DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating
More informationKitchen Hygiene. Kitchen Hygiene
Can t find what you re looking for? Give us a call. Kitchen Hygiene Kitchen Hygiene Kitchen Cleaners & Descalers... 1-2, 7 Glasswear Detergents... 1 Beer Pipeline Cleaners... 2 Oven Cleaners... 2, 7 Hand
More informationAspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement.
Aspects of the Compressor Retrofit Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement. B y J o h n P r a l l a n d D e n n y M a r t i n All
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationRefrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies
Refrigerants Management & Retrofits Mike Saunders & Randy Tebbe Emerson Climate Technologies Agenda Refrigerant Landscape and Proposed Regulation Review Life Cycle Climate Performance Refrigerant Phase-Down
More informationINSTALLATION INSTRUCTIONS
2016 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Elite Series XC16 Units AIR CONDITIONER 507161-01 8/2016 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE General This
More informationTRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999
TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table
More informationMethod to test HVAC equipment at part load conditions
IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationREFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES
/ ACCESSORIES High performance Lightest vacuum pump VACUUM PUMP.8CFM Eco Applicable to room air-conditioner, package air conditioner up to 5HP.8CFM Eco Code No.WV0 Suitable for vacuuming small 5HP refrigeration.
More informationSERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI 89/336 73/23 SELF-CONTAINED CRESCENT CUBER KM-150BAF-E KM-150BWF-E
89/336 73/23 NUMBER: 73108 ISSUED: APRIL 19, 2000 REVISED: JAN. 13, 2004 SELF-CONTAINED CRESCENT CUBER KM-150BAF-E KM-150BWF-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI IMPORTANT Only qualified
More informationActions to Control Emission of HFCs in Japan
Actions to Control Emission of HFCs in Japan Implementation of the Act on Rational Use and Proper Management of Fluorocarbons Kazuhiro Sato JRAIA (the Japan refrigeration and Air Conditioning Industry
More informationWARRANTY LABOR CLAIM
True Manufacturing 2001 East Terra Lane O Fallon, MO 63366-4434 Phone#636-240-2400 855-878-9277 Fax#636-980-8510 warrantyclaims@truemfg.com WARRANTY LABOR CLAIM INSTRUCTIONS FOR COMPLETING FORM: 1. Model
More informationCleaning. Internal cleaning of refrigeration systems. Internal cleaning of heat transfer fluid circuits
Cleaning Internal cleaning of refrigeration systems Internal cleaning of heat transfer fluid circuits Water treatment for heating and cooling closed loops External cleaning of thermal installations CLEANING
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21, TRS21C, TRS21S Evaluated for
More informationENERSAVE Hydrocarbon Scroll Water Cooled Chiller
ENERSAVE Hydrocarbon Scroll Water Cooled Chiller Your Green Input to Chiller ever found in the market To eliminate the threat of environmental impact by utilizing environmental friendly refrigerant gas-
More informationNO. F ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AA KMD-201AWA MODEL SERVICE MANUAL
NO. F037-775 ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER MODEL KMD-201AA KMD-201AWA SERVICE MANUAL CONTENTS PAGE I. SPECIFICATIONS ---------------------------------------------------------------------------------------
More informationMTW Series Modular Oil Free Centrifugal Chillers
TW Series odular Oil Free Centrifugal Chillers Cooling Capacity:300-2890kW odular Chiller agnetic Levitating Centrifugal Compressor Stainless Steel PHE Refrigerant R134A ax. COP: 12w/w TW Series odular
More informationINSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold
LOW VAC INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold REF HIGH SPECIAL FEATURES Low battery indicator Displays 63 refrigerants Displays corresponding saturation, dew or bubble point temperature
More informationApplication Guide. Retrofit Guidelines
Application Guide Retrofit Guidelines APP-APG011-EN Replacing systems that use HCFC-22 Reusing existing refrigerant lines Converting HCFC-22 systems to HFC410A Converting HFC410A indoor units to HCFC-22
More informationcondenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications
Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL
More informationCLI Refrigerant Gas Leak Detector. User s Guide
el-520 CLI20204 Refrigerant Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-520 Refrigerant Gas Leak Detector, the most technologically advanced of its kind. The el-520
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram
More informationControl of refrigerant gases during manufacture, installation, servicing
The Australian automotive code of practice 2008 Control of refrigerant gases during manufacture, installation, servicing or de-commissioning of motor vehicle air conditioners Motor Trades Association of
More informationCLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.
CLEANING Application Recommendations Application/ Concerns Laboratory Reproducible results, no interfering residues, extending equipment life. Keep laboratory accreditation. Laboratory safety. Articles
More informationPROLAQ. CLEANING SOLUTIONS Cleaning all around varnishing MAKING GREEN WORK.
PROLAQ CLEANING SOLUTIONS Cleaning all around varnishing Bio-Circle Surface Technology GmbH Fly - PROLAQ - EN - AL1 2016 Subject to technical modifications. Errors and omissions excepted. All contents
More informationTube-in-tube heat exchanger Type HE
MAKING MODERN LIVING POSSIBLE Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration
More informationHOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-280MAH KM-280MWH SERVICE MANUAL
NO. 73117 ISSUED: AUG. 15, 2004 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-280MAH KM-280MWH SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt to service or maintain this
More informationR-407A R-448A R-449A
GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants
More informationFluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE
Fluid Exchange Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories 423 ASCOT 424 Refrigerant Recovery/Recycling Systems Recovery and Recycling Systems
More informationManifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.
Manifold Gauge LD.R1.01 manifold gauge brass body LD.R1.02 manifold gauge brass body LD.R1.03 manifold gauge aluminum body LD.R1.04 manifold gauge aluminum body LD.R1.05 manifold gauge aluminum body LD.R1.06
More informationSporlan Valve Division Parker Hannifan/CIC Group
www.parker.com/cic Sporlan Valve Division Parker Hannifan/CIC Group Matt McGrath, SW Regional Sales Manager Bob Dolan, Sales Engineer - Atlanta www.parker.com/cic Why Discuss TEVs Today? Expansion Valves
More informationCopeland Scroll Condensing Units for the Food Service Market
Copeland Scroll Condensing Units for the Food Service Market...with Best In Class Emerson System Protection Components Medium and Low Temperature Refrigeration Applications R-404A 1.5 to 10 Hp Reliable
More informationNUMBER: ISSUED: JULY 13, /336 73/23 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI
89/336 73/23 NUMBER: 73141 ISSUED: JULY 13, 2006 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI IMPORTANT Only qualified service technicians should attempt
More informationDuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options
DuPont Refrigerants R22 market and the ISCEON retrofit options Airefrig November 2010 John McCormack Business Manager DuPont Chemicals and Fluoroproducts HCFC Regulations & ISCEON 3 Actions Impacting Fluorochemicals
More informationR Series Cooling Manual
Mini Duct Heating and Air Conditioning Indoor Air Quality Systems R Series Cooling Manual Includes: RPM-E-50 Cooling Module RPM-E-0 Cooling Module RPM-E-00 Cooling Module Manufactured By Energy Saving
More information