1 Electric Heater Kit For use with GB, GP and GT eries Geothermal Heat Pumps KWAEH0101N05 KWAEH0101N10 KWAEH0101F15 KWAEH0101F20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. AFETY CONIDERATION Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory -authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit.. Consult local building codes and current editions of the National Electrical Code ( NEC ) NFPA 70. In Canada, refer to current editions of the Canadian electrical code CA Recognize safety information. This is the safety -alert symbol!!. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety -alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestionswhich will result in enhanced installation, reliability, or operation.! WARNING ELECTRICAL HOCK HAZARD Failure to follow this warning could result in personal injury or death. Before beginning any installation or modification, be sure the main electrical disconnect switch is in the OFF position. TAG THE DICONNECT WITCH WITH A UITABLE WARNING LABEL Unit contains two power supplies - make sure BOTH are off before servicing.! CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in compressor damage. NEVER turn unit on its top or side to install support feet.! CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in unit damage. This Electric Heater Kit is designed for installation in the heat pump model published in this document. Do not install this heater kit in a heat pump not specified in this manual.! CAUTION CUT HAZARD Failure to follow this caution may result in personal injury. heet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. INTRODUCTION The Electric Heater Kit is a field installable electric resistance heater kit designed for the GB, GP and GT series heat pumps. The heater kit requires separate electrical service connection, independent from the heat pump s power supply. Installation of this Heater Kit will convert the heat pump into a two point power connection. The Heater Kit is available in several kw capacities. Unit tonnage vs Heater Kit capacity compatibility table is below. The Heater Kit can be installed on vertical (VT), horizontal (HZ) and counter-flow (CF) units. Aux. Heat ize Compatibility GHP Model 5Kw 10 Kw 15 Kw 20 Kw GT GT GT048 GT060 GT072 GP GP GP048 GP060 GP072 GB GB GB GB GB GB048 GB060 = Heater Kit compatible / = Heater Kit NOT compatible

2 AUXILIARY HEATER KIT NOMENCLATURE K W A EH F 15 Kit Usage W = Water ource / Geothermal eries A = Current Type EH = Electric Heat equential 01 = Current KW 05 Kw 10 Kw 15 Kw 20 Kw Circuit Protection F = Fused (15, 20 Kw) N = Non-fused (5, 10 Kw) Pack 01 = ingle! PRE -INTALLATION CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in unit damage. DO NOT wire the heater elements into the same circuit as the compressor. IMPORTANT: Electric Heater Kit can only be installed on single phase units. IMPORTANT: A heater collar is installed in the geothermal heat pumps so there is no need to order a collar separately. IMPORTANT: A heat pump thermostat with supplemental electric heat feature is required to operate the system when this kit is installed. Unpacking and Inspection 1. Unpack the heater kit and inspect contents and condition. If any part or the kit appears damaged (i.e.: broken heater elements, damage relays) or missing, do not attempt to install the kit. Contact your local distributor for further help. 2. Ensure that the heater kit package includes all the listed components. Contact your local distributor for further help. Components List: Pre -wired heater electrical box (including fuses on KWAEH0101F15 and KWAEH0101F20) Heater elements Heater element(s) protective metal cover Wire harness pre -wired at one end. Wiring diagram Adhesive backed electrical data label Clear hardware accessory bag containing: - Heater element mounting screws (4 for each element bank) - Heater element cover mounting screws (2 for each cover) - Four electrical box mounting screws - Push in wire ties - This installation manual Required Tools: Phillips screwdriver mall flat head screwdriver 5/16 socket and a ratchet or drill Wire cutter Wire stripper Torque Phillips head screwdriver Multi meter ELECTRIC HEAT KIT The Electric Heat field installed kit contains two main electrical enclosures: Electric Heat Control Box and Electric Heat Elements, both are located in the blower compartment. (Fig. 1 through Fig. 4) The control box attaches to the corner post and the heat elements to the blower heater collar in the blower compartment. Fig. 1 Electric Heater Element Cover (1) and Electric Heat Control Box (2) Location - Vertical Configuration 2 Fig. 2 Electric Heater Element Cover (1) and Electric Heat Control Box (2) Location - Counterflow Configuration

3 Fig. 3 Electric Heater Element Cover (1) and Electric Heat Control Box (2) Location - RH Horiz. End Discharge Config. Fig. 5 Disconnect Unit Display 4. Remove the access panel(s) from the unit exposing the blower section and compressor section of the packaged heat pump unit. 5. Remove the heater collar cover plate(s) (see Fig. 6) Fig. 4 Electric Heater Element Cover (1) and Electric Heat Control Box (2) Location - LH Horiz. End Discharge Config. INTALLATION - HARDWARE 1. At Thermostat Turn system to OFF 2. Turn the main power to the heat pump to OFF at the unit s disconnect switch or breaker panel.! WARNING ELECTRICAL HOCK HAZARD Failure to follow this warning could result in personal injury or death. Before beginning any installation or modification, be sure the main electrical disconnect switch is in the OFF position. TAG THE DICONNECT WITCH WITH A UITABLE WARNING LABEL Unit contains two power supplies - make sure BOTH are off before servicing. 3. Prior to removing the blower panel, disconnect unit display from the back of the panel (see Fig. 5) Fig. 6 Heater Collar Cover Plate Removal 6. In preparation for heater element installation, orient the heating elements with thermal overloads (cut-outs) are on the right side for VT & CF and top for HZ (see Fig. 7)! CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in unit damage. Proper thermal overloads (cut-outs) orientation is required for safe unit operation. 3

4 INTALLATION - WIRING The electric heater control box is completely pre -wired from the factory. There are two Electric Heater control box layouts depending on heater kit model (see Fig. 10 and Fig. 11) HR1 controls heating elements 1 and 3 and HR2 controls heating elements 2 and 4. Fig. 7 Thermal Overloads Cut -Outs 7. Insert heating element(s) into collar. Heating element rods must be inserted into inner most holes as shown in Fig. 8. This will support and prevent vibration of heater elements. IMPORTANT: Model sizes 060 and 072 have an additional extension bracket mounted on each cover plate. Heating element rods must be aligned to extension brackets accordingly. Fig. 10 5kW-10kW Control Box (KWAEH0101N05 / KWAEH0101N10) Fig. 8 Heating Element Rods IMPORTANT: If only one heating element is being installed, install it into the position closest to the blower wheel. Cover remaining opening with one of the cover plates removed in step ecure each insert with four of the supplied sheet metal screws (see Fig. 9) Fig kW-20kW Control Box (KWAEH0101F15 / KWAEH0101F20) 1. Route the high voltage Red and Black wires, originating from the Electric Heater control box, through grommets in the Electric Heater Element cover as show in Fig. 12. IMPORTANT: Route all red wired together through the same grommet and black wires through the second grommet. Fig. 9 ecure Insert with upplied heet Metal crews 4

5 TO CONTROL IGNAL TO BLOWER MOTOR POWER ATTACH TO ELECTRICAL HEAT BOX J12 J19 1 J39 2 TRANFORMER POWER 1 = red wire 2 = black wire Fig. 12 Routing Red and Black Wires 2. For vertical (VT) and horizontal (HZ) units, install the heater control box between the unit corner posts at the bottom of the of the blower section. For counter flow (CF) units, install the heater control box between the unit corner posts at the bottom of the of the blower section. (ee Fig. 1 through Fig. 4) Orient the heater control box with contactor(s) towards bottom Holes for control box are pre-punched between the metal parts. 3. Connect red and black high voltage wires, originating from Electric Heater control box, to the Electric Heater elements as shown in Fig. 13. Terminate Black wires labeled HL at the thermal limits (cutouts) and Red wires labeled HT at the heater element connections (see Fig. 13 and 14). NOTE: Each wire is labeled for ease of identification. ee wiring diagram on page Fig. 14 Electric Heater Harness 7. Route J39 plug through the hole in the divider panel and mate the plug to the receiving connector P39 on the side of the electric heat control box. 8. Re-apply cork tape to the divider panel hole. 9. Route the other end of the harness (3 connector end) along the already installed blower harness, and terminate it at the unit electrical box (E -Box). Use tie-wraps every inches for a neater finish. Fig. 13 Heater Element 4. Install the cover for the control box with the provided screws. 5. Remove and retain cork tape covering the hole in the divider panel. 6. On the wiring harness supplied with this kit, identify J39 plug. (Fig. 14) Fig. 15 J19 Blower Plug (two position) 5

6 11. Mate J19 plug originating from the electric heat control box (red and black wires) with P19 plug originating from blower harness at E -box (see Fig. 19). IMPORTANT: When mating plugs, push both connectors together until they snap with a click. Fig. 16 P12 Control ignal Plug (three position) Fig. 19 Mate J19 from Electric Heat Control Box to P19 from Blower Harness at E -box 12. Disconnect the red and black line voltage harness from the transformer primary side and the contactor line side. Remove the harness from the E -box entirely. (ee Fig. 20 and 21) Fig. 17 Transformer Power 10. In the heat pump electrical box, disconnect the J19/P19 high voltage wires that connect the blower motor to the line voltage these wires are located on the left -hand side of the E -box shown in the Fig. 18. Fig. 20 Transformer Primary Connected Fig. 21 Primary Disconnected Fig. 18 Disconnect J19/P19 High Voltage Wires 6

7 13. Route the two line voltage wires that derived from the P19 plug, these wires should be routed under the contactor along the bottom of the electrical box (see Fig. 22).! CAUTION PERONAL INJURY AND/OR UNIT DAMAGE HAZARD Failure to follow this caution may result in personal injury and/or unit damage. When routing wiring, avoid sharp edges as these can chafe wiring insulation, exposing the conductor which can result in equipment damage and personal injury. Fig. 24 P12 Plug mated to J12 Plug 17. Ensure heater element wires are routed through the plastic bushings available in the kit, and perform a continuity test to ensure all connections are secure. IMPORTANT: Use bottom holes on the plate to inset the plastic grommets and prevent the wires from laying on sharp edges (see Fig. 25). Fig. 22 Route Line Voltage Wires from P19 Plug 14. Connect red and black wires from electric heat harness to transformer primary winding per wire labels. 15. There will be one harness (black and white wires) left-connected to the compressor contactor. Remove and discard this loose harness from the contactor (see Fig. 23) Fig. 25 Plastic Grommets to Prevent Wire Damage 18. Remove two (2) screws as shown in Fig. 26. Fig. 23 Connecting Red & Black Wires from Elect. Heat Harness to Transformer Primary Winding 16. There should now be one plug left labeled P12 on the electric heat harness. Mate this plug to its counterpart plug already available on the left-hand side of the E -box labeled J12. (ee Fig. 24) Fig. 26 Remove Two (2) crews 7

8 19. Mount heater element cover to blower collar using four (4) screws as shown in Fig. 27. Fig. 27 Mount Heater Element Cover to Blower Collar 20. Use push in wire ties to secure cables to cover and blower bracket (see Fig. 28) Fig. 28 ecure Cables to Cover and Blower Bracket ITE LINE VOLTAGE CONNECTION Routing new line voltage wires from circuit breaker panel to heater electrical box: 1. elect the proper wire size based upon the heater electrical load that the blower motor and electric heater element(s) will require. Refer to the data tag label that is included in the heater kit or the electrical data at the end of this manual. Ensure that all national and local electrical codes are followed for installation, wire sizing, and breaker sizing. 2. elect the proper breaker size based upon the heater electrical load that the heat pump will require. Refer to the data tag label that is included in the heater kit or the electrical data at the end of this manual. 3. Route the new line voltage wiring and the ground wire from the circuit breaker panel to the heat pump. 4. Use the knockout provided in the heat pump corner post as the entry for the electrical service wiring. A plastic bushing should be used to protect the wire insulation from the metal edge of the knockout 5. Connect one of the line voltage wires to L1 terminal connection and the other line voltage wire to L2 terminal connection. Torque to 22 in -lbs. 6. Use the ground lug provided in the heater control box to connect the field ground from the power supply. WIRING DIAGRAM PLACEMENT 1. Remove the wiring diagram that is adhered to the back side of the front panel. Replace with the wiring diagram that was included with the heater kit (using spray adhesive glue is recommended). 2. Place the adhesive backed heater data label next to the knockout in the post where the new electrical service for the fan motor and heater elements is entering the cabinet. UNIT TART -UP 1. Turn the disconnect switch or breaker switch to the ON position for the compressor and for the new separate circuit servicing the blower motor and the heating elements. 2. Run the unit in heating mode with the heating elements engaged for at least 10 minutes to ensure the unit does not shut down due to any temperature limiting device. THERMOTAT WIRE CONNECTION 1. Assure that two low voltage wires are available from the thermostat to make the W1 and EM connections. If these wires are not located, they will need to be pulled and routed from the back of the thermostat to main thermostat connections on the electrical box or to the motor control board. 2. trip the insulation off of the W1 and EM wires and insert into the thermostat control wire block or on the motor control board thermostat interface. Connect the other end of the wires to the back of the thermostat to the supplemental and emergency heat terminals. Reference the Thermostat Manual for proper connection. Fig. 29 Connect Thermostat Wires 8

9 ELECTRIC HEATER ELECTRICAL DATA Electric Heater Kit Number Rated kw tage Heater Watts Heater AMP Circuit MCA MOP 240V 208V 240V 208V Fuses 240V 208V 240V 208V KWAEH0101N ,800 3, F1/F KWAEH0101N ,600 7, F1/F KWAEH0101F KWAEH0101F ,600 7, F1/F ,400 10, F3/F4 1 9,600 7, F1/F ,200 14, F3/F

10 WIRING DIAGRAM Fig. 30 Electric Heater Wiring Diagram 10

11 WIRING DIAGRAM Fig tage (2 tep) ingle Phase EOM Motor 11

12 WIRING DIAGRAM Fig. 32 E-Box 12

13 WIRING DIAGRAM Fig. 33 Wiring Harness 13

14 (2013/12) Copyright 2014 CAC / BDP 7310 W. Morris t. Indianapolis, IN Edition Date: 05/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 Catalog No: IIK -KWAEH -01 Replaces: New

Installation Instructions

Installation Instructions Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

SM Field Installed Electric Heat Kit

SM Field Installed Electric Heat Kit SM Field Installed Electric Heat Kit HK050 HK100 HK150 HK200 Installation Manual 8733822029 (2018/07) US 2 SM Series Electric Heat Installation Manual Data subject to change 07.2018 8733822029 Installation

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

Installation Instruction

Installation Instruction KGADC0101BVC INTERNAL VENT KIT Installation Instruction NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

Installation Instructions

Installation Instructions ---751,---754,---755,---756 Condensing Heat Exchanger Kit Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation,

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11

More information

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS KSAIF KSAIF0501AAA & KSAIF0601AAA Wi-Fi Interface Kit for Ductless Systems INSTALLATION INSTRUCTIONS NOTE: Read and become familiar with these instructions before beginning installation. TABLE OF CONTENTS

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the

More information

Installation Instructions

Installation Instructions KSALA0201R22 KSALA0301410 Low--Ambient Pressure Switch Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Installation Instructions

Installation Instructions HC2 HC3 HOT WATER COILS MULTIPOISE Installation Instructions NOTE: Read the entire installation instructions before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,

More information

Owner s Information Manual

Owner s Information Manual 50EZ---A and 50VT ---A Comfort and Performance 13 and 14 SEER Single Packaged Heat Pump System With PuronR (R ---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Owner s Information

More information

Installation Instructions

Installation Instructions HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can

More information

Installation Instructions

Installation Instructions Evaporator Coil A Coil --- Cased Multipoise NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

Installation Instructions

Installation Instructions PART NUMBER: 001A00 002A00 SMALL PACKAGED PRODUCTS 1---1/2 TO 5 TONS (50/60 HZ) MOTORMASTER II HEAD PRESSURE CONTROLLER Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions Toshiba Carrier RAV Series Ductless Wind Baffle Fabrication and Installation RAV-SP180AT2-UL RAV-SP240AT2-UL RAV-SP300AT2-UL RAV-SP360AT2-UL RAV-SP420AT2-UL Installation Instructions SAFETY CONSIDERATIONS

More information

Installation Instructions

Installation Instructions 53DS --- 900 --- --- --- 092 Duct---Free Systems Accessory Power Ventilation Kit for In --- Ceiling Cassette Fan Coil Units Size 018 --- 036 Installation Instructions NOTE: Read and become familiar with

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions PART NUMBER: 001A00 002A00 SMALL PACKAGED PRODUCTS 2 TO 5 TONS (50/60 HZ) MOTORMASTER II HEAD PRESSURE CONTROLLER Installation Instructions NOTE: Read the entire instruction manual before starting the

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. Installation NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION... 2 Inspect Equipment... 2 Select

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT

More information

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA INSTALLATION INSTRUTIONS Low Ambient Kit NASA201LA, NASA401LA These instructions must be read and understood completely before attempting installation. DANGER, WARNING, AUTION, and NOTE The signal words

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump Packaged Heat Pumps Owner s Guide to Operating and Maintaining Your Heat Pump NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces

More information

Installation Instructions

Installation Instructions Coupling Box Kit Cancels: IIK 340M-40-79 IIK 340M-40-88 9-05 Installation Instructions Part No. 320721-765, 330539-751, -752, -753, -754, -755, -756, and -757 NOTE: Read the entire instruction manual before

More information

Fig. 1 - Unit PHD4 and WPH4

Fig. 1 - Unit PHD4 and WPH4 OWNER S MANUAL 14 SEER Single -Package Heat Pump System with R -410A Refrigerant Single Phase and Three Phase 2 to 5 Nominal Tons PHD4 Series F and WPH4 Series B Fig. 1 - Unit PHD4 and WPH4 A09034 NOTE

More information

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems Owner's Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 3 WIRED CONTROLLER FEATURES AND FUNCTIONS... 5 WIRED CONTROLLER

More information

Installation Instructions

Installation Instructions EZXCAB Sizes 016 and 020 High Efficiency Air Filtration System Installation Instructions JAN High Efficiency Air Filtration System Fig. 1 - EZXCAB C04001 NOTE: Read the entire instruction manual before

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

Installation Instructions

Installation Instructions CNPHP Cased N s Horizontal Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION...

More information

Installation Instructions

Installation Instructions CNPHP Cased N Coils Horizontal Heating --- Cooling NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

Installation Instructions

Installation Instructions P700U -21NHP Base Non -Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A14005 Base Non---Programmable Thermostat

More information

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions Read and become familiar with these instructions before beginning installation. KSAIC020230 (208-230V) 24V Interface Kit for Ductless Outdoor Single Zone matched with Air Handler Installation Instructions Read and become familiar with these instructions before beginning installation.

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION ELECTRIC HEAT S THRU 05 5 THRU Supersedes: (9) (00) 0-5 FOR SINGLE PACKAGE CONDITIONERS THRU TON SINGLE PACKAGE HEAT PUMPS THRU 5 TON GENERAL This instruction contains all the

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND

More information

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner. Packaged Air Conditioning Units Owner s Guide to Operating and Maintaining Your Air Conditioner ELECTRICAL SHOCK HAZARD. Failure to follow this warning could result in personal injury, Disconnect power

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

Installation Instructions Part No

Installation Instructions Part No Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units P.O. Box 245 Syracuse, NY 13211 www.roth-america.com 888-266-7684 Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units P/N: 2300100902 Table of Contents: Section

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions CRSMKKIT002A00 CRSMKSEN002A00 FIELDINSTALLEDSMOKEDETECTORS FOR MEDIUM ROOFTOP UNITS 15 to 25 TONS Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 SAFETY CONSIDERATIONS... 1 GENERAL...

More information

Installation Instructions

Installation Instructions Primary Cell Inlet Panel Kit Installation Instructions Part No. 320720-751, -753, -754, -755, -756, -757,-758, and -760 NOTE: Read the entire instruction manual before starting the installation. This symbol

More information

Installation Instructions

Installation Instructions 40MBD Ducted Style Ductless System Sizes 09 to 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40MBD / 38MAQ / 38MBQ Ducted tyle Ductless plit ystem izes 09 to 48 Owner s Manual TABLE OF CONTENT PAGE A NOTE ABOUT AFETY... 2 GENERAL... 2 PART LIT... 3 DIPLAY PANEL... 4 REMOTE CONTROL... 6 REMOTE

More information

Installation Instructions

Installation Instructions CAELHEAT001A00 - CAELHEAT039A00 AAHC05AHAA - AAHC70ESAA PACKAGED AIR---HANDLING UNITS ELECTRIC HEAT ACCESSORY 6 to 30 TONS (21 to 105 kw) 50/60 Hz Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS...

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

Installation Instructions

Installation Instructions H6HK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers IMPORTANT: The instructions included with this heater kit are for installations

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless plit ystem izes 009 --- 024 Owner s Manual TABLE OF CONTENT PAGE AFETY PRECAUTION... 2 GENERAL... 2 INDOOR UNIT PART NAME... 3 REMOTE CONTROL PART NAME...

More information

Installation Instructions

Installation Instructions 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes

More information

Installation Instructions

Installation Instructions Installation Instructions For Cased and Uncased Coils Upflow-Downflow Heating-Cooling CK5A, CK5B Cased CJ5A Uncased SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Electric Heat Sections Used with Blower Coil Units ELECTRIC HEAT SECTIONS 505,084M (0655012-30) 05/15 Supersedes 09/11 Litho U.S.A. NOTICE TO INSTALLER IT IS HIGHLY RECOMMENDED

More information

Installation Instructions

Installation Instructions Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

Installation Instructions

Installation Instructions 40MHH High Wall Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes only. Actual

More information

Installation Instructions

Installation Instructions 022-7/8 015-5/8 53DS --- 900 --- --- --- 117 (115 v) 53DS --- 900 --- --- --- 118 (230 v) Accessory ondensate Pump for Ductless Split System Installation Instructions NOTE: Read and become familiar with

More information

Installation Instruction

Installation Instruction Installation Instruction Upflow Downflow Heating Cooling CC5A Uncased Coil CD5A Cased Coil SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Installation of CD5A Cased Coil A96244 NOTE:

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Installation Instructions

Installation Instructions Installation Instructions Blower Packages For Gas Furnaces KCBBA00TG KCBBA00TG NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION When upgrading a Coleman, Intertherm,

More information

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT HUM Cancels: II 912D-56-3 II HUM-56-1 7-98 MODEL HUMBBLFP1025-A-- FAN-POWERED HUMIDIFIER MODEL HUMBBLBP2018-A-- BYPASS HUMIDIFIER MODEL

More information

Installation Instructions

Installation Instructions Installation Instructions Manufactured Housing Blower Package for Electric Furnaces KMABA----TE KMABA----TE NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS

More information

Installation Instructions

Installation Instructions CRLVHLGD004A00 CRLVHLGD011A00- CRLVHLGD016A00, CRLVHLGD020A00- CRLVHLGD024A00 CRLVHLGD032A00, CRLVHLGD045A00 Installation Instructions SMALL ROOFTOP UNITS ACCESSORY LOUVERED HAIL GUARD GAS HEATING/ELECTRIC

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

Installation Instructions

Installation Instructions Installation Instructions For Cased Coils Upflow-Downflow Heating-Cooling CK5A CK5B SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation NOTE: Read the entire instruction

More information

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 RECORD THIS INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number ADB Model Number ADB Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

More information

Installation Instructions

Installation Instructions TB --- PAC01 --- A TB --- PHP01 --- A Base Series Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A07107 Base

More information

Installation Instructions

Installation Instructions 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models) Installation Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models) VEWD527 / CVEWD527 / VEWD530 / CVEWD530 VEWDO530 / CVEWDO530 / VEWDO536 / CVEWDO536 Table of Contents Warnings &

More information

Installation Instructions

Installation Instructions 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,

More information

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 To prevent accidents, which could cause serious injury or death, as well as machine damage read these instructions before installation

More information

Installation Instruction

Installation Instruction 40GRQ / 619FB / 38GRQ / 538FR High- Wall Ductless Split System Sizes 09-18 Installation Instruction NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

Installation. Built-in Full Height Wine Cellar VCWB301

Installation. Built-in Full Height Wine Cellar VCWB301 Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information

More information

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions Read and become familiar with these instructions before beginning installation. KSAIC005 (5V) KSAIC00230 (208-230V) 24V Interface Kit for Ductless Systems Installation Instructions Read and become familiar with these instructions before beginning installation. SAFETY CSIDERATIS Read

More information

Installation Instructions

Installation Instructions 40MAQ / 38MAQ 619PB / 538PR High---Wall Ductless Split System Sizes 09 to 30 Installation Instructions TABLE OF CONTENTS PAGE PARTS LIST... 2 SAFETY CONSIDERATIONS... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS...

More information

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662) Installation Viking Range, LLC Front Street Greenwood, Mississippi 890 USA (66) 455-00 For product information, call -888-845-464 or visit the Viking Website at vikingrange.com U L C U L 4 Series Built-In

More information

Installation Instructions

Installation Instructions Heat Exchanger Cell Replacement Kit Cancels: IIK 373-35-12 IIK 373L-35-14 12-15-93 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS C7BA Series Split System Indoor Cased Coils IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able

More information

Installation Instructions

Installation Instructions H5HK Series Installation Instructions 3 Phase Electric Heater Kits Light Commercial Package A/C and Heat Pump Systems Description Installation of 208/240V and 480V H5HK 3 Phase Heater Kits in 6, 7.5 and

More information