Service & Trouble Shooting Manual

Size: px
Start display at page:

Download "Service & Trouble Shooting Manual"

Transcription

1 Service & Trouble Shooting Manual Condensing Dual Purpose Water Heater (REV )

2 TABLE OF CONTENTS 1. Installation (authorized personnel only) 3 Installation Of The Dual Purpose Water Heater (DPWH) 3 Water Connections 3-4 Gas Connection 4 Electrical Connections 4 2. Commissioning The Appliance 5 General Warnings 5 Filling The System 6 Filling The Condensate Trap 7 Ignition Of The DPWH 7 Heating Mode 8 Domestic Mode 9 3. Maintenance (Authorized Personnel Only) 10 General Warnings 10 Dual Purpose Water Heater (DPWH) Inspection 10 Draining The Central Heating And Domestic Hot Water System Troubleshooting Error Codes Diagnostics 12 E01 Ionization / Flame Sensor Lock-Out E02 Safety Thermostat Tripped / Air Pressure Switch Tripped E03 Flue Gas Thermostat (Thermofuse) Tripped H2O Low Water Pressure Alarm E05 Heating Sensor Malfunction E06 D.H.W Sensor Malfunction E12 D.H.W Storage cylinder Sensor Malfunction E16 Induced Draft Electric Fan Malfunction E22 Parameter Programming Request E35 Flame Sensor Malfunction E42 Fan Printed Circuit Board Malfunction Exploded Parts View Flowmax 90 Hydraulic System 37 Flowmax 90 Thermal System 38 Flowmax 120 Hydraulic System 39 Flowmax 120 Thermal System 40 Flowmax 170 Hydraulic & Thermal System Function Codes Flue Test Function Active (Chimney-Sweeper) Frost Protection Central heating circuit Frost Protection Domestic Hot Water (D.W.H.) circuit Frost Protection Domestic Hot Water (D.W.H.) circuit for storage DPWH Legionella Prevention Function Incompatible Remote Control

3 1. Installation (authorized personnel only) 1.1 Installing the Dual Purpose Water Heater (DPWH) The cardboard material used for packaging the appliance is fully recyclable. It is recommended that the packaging material is only removed prior to installing the DPWH. The manufacturer will not be held responsible for damage caused by incorrect storage of the product. 1.2 Water Connections In order to safeguard the primary heat exchanger and circulation pump, especially in case of DPWH replacement, it is recommended that the system is hot-flushed to remove any impurities (oil and grease) from the pipes and radiators. If this DPWH is installed in an application where the supply water is hard, it must be treated with either a water softener and or a filtration system which removes hardness within the water or by using sequestering agents that reduce the amount of scale deposits. Damage to the DPWH as a result of water in excess of 14.5 gpg (250mg/L) of hardness is not covered by FLOWMAX Limited warranty. If there a problem with the water quality, contact your local water conditioning company for equipment to condition the water supply to this appliance. The cold water supply pressure at the inlet to the DPWH must be between 7.25 psi (0.5 bar) and 87 psi (6 bar). In areas with higher water inlet pressure a pressure reducing valve must be installed before the DPWH. The frequency of the primary heat exchanger coil cleaning depends on the hardness of the main water supply and the presence of residual solids or impurities, which are often present in the case of new installations. If the characteristics of the main water supply are such that require it to be treated, an appropriate treatment device should be installed. While in the case of residues, an in-line filter should be sufficient. Central Heating Circuit In order to prevent scaling or deposits from forming in the primary heat exchanger, the main supply water to the heating circuit must be treated according to the requirements of local standards. This treatment is indispensable in cases where the system is frequently topped-up or when the system is often either partially or fully drained. Condensate Drain FLOWMAX DPWH is a high efficient gas appliance that creates condensation when operating. A condensate trap and flexible drain pipe comes factory installed inside each unit. The condensate trap must be primed before operation to prevent exhaust gases from entering the building. Follow your local code with regards to the disposal of condensation Here are several options for disposal of condensate o o o o From combination DPWH direct to drain From combination DPWH to neutralizer to drain From combination DPWH to laundry tub (bottom of DPWH must be above the height of the laundry tub & must have a negative slope to properly drain) From combination DPWH to condensate pump to laundry tub (for long distances between DPWH and laundry tub or when bottom of the DPWH is installed below height of the laundry tub) Failure to install the condensate discharge properly will affect the reliability of the DPWH. All units installed with vertical exhaust must have an additional approved condensate drain. Fittings must be ULC S636 approved. Failure to properly connect the condensate line will cause combustion gases to enter the room, possibly causing serious injury to occupants or death

4 Note: Check with your municipality, local codes, or local gas company to determine if disposal of combustion condensate is permitted. In the State of Massachusetts the condensate must be neutralized prior to entering a drain. Use only PVC, vinyl or CPVC pipe for the condensate drain line, metal pipe work is not suitable for condensate discharge system. The condensate drain line should be a minimum of ½ diameter. It connects to the existing corrugated hose and must be supported to prevent sagging. The manufacturer supplies a barbed ¾ to ½ reducer for this connection. Keep the length of the condensate drain as short as possible. Long runs or applications where the nearest drain is above the DPWH will require the use of a condensate pump. Size the pump to allow for a maximum condensate discharge of 2 gpm from the DPWH. The end drain pipe must not be submerged in water or blocked in any way. Condensate will begin flowing out of the DPWH within 15 minutes after operation has started. Be certain to check that condensate is freely flowing from the drain piping after the system has been installed. Do not run the condensate line outside. Take measures to prevent the condensate drain lines from freezing (insulation, heat tape, electric heaters, etc.) if in unconditioned space. Be sure to clean the condensate trap at least once per year to prevent any problems. Be sure to check and clean the condensate trap to prevent blockage. After cleaning, be sure to check for any leaks of condensed water or flue gas. 1.3 Gas Connection Check the internal and external seals of the gas supply system. A gas cock must be installed upstream of the appliance Before starting the appliance, ensure the type of gas corresponds to that for which the appliance has been setup. The gas supply pressure must be between the values reported on the rating plate. Conversion of the appliance from Natural Gas to LPG or vice versa must be carried out by qualified personnel. 1.4 Electrical Connections DO T connect VAC and any other voltage to this FLOWMAX Combination DPWH. This will damage the DPWH and void the warranty. The electrical supply required by the DPWH is 120VAC at 60Hz with proper grounding. If the main power supply wire leads are damaged in any way, switch off the appliance and have the wire leads replaced by a qualified electrician

5 2. Commissioning the Appliance 2.1 General Warnings The following operations must be carried out by professionally qualified personnel, registered in accordance with current legislation. The DPWH leaves the factory pre-set and tested for burning Natural Gas. Nevertheless, when starting the DPWH for the first time, make sure that the information on the rating plate corresponds to the type of gas being supplied to the DPWH. Once the system has been filled and the necessary adjustments made, remember to tighten the screws of the gas valve test port. Ensure there are no gas leaks from the tests port and from any pipe fittings upstream of the gas valve. Ensure there are no gas leaks from the test port and from any pipe and or fittings. Preliminary Operations Switching the DPWH on for the first time means checking that the installation, regulation and operation of the appliance are correct: Check that the rating on the rating plate corresponds to that of the main electrical supply networks (gas, electricity, water). Check that the power supply voltage to the DPWH complies with the rating plate (120V 60Hz) and that the live, neutral and ground wires are properly connected. Check that the gas supply is correctly sized for the flow rate required by the DPWH and that it is fitted with all the safety and control devices stipulated by current regulations. Check that the supply of combustion air and exhaust and condensate discharge systems are functioning correctly and are in line with current codes and standards. Check that the exhaust vent and its connections to the termination comply with the requirements of current codes and standards for the type of appliances installed. Check that the service valves are open. Check that the condensate drain system including outside the DPWH (exhaust system condensate collection devices), allows the condensate to flow freely to the drain. Check that there are no flammable materials or liquids in the immediate vicinity of the DPWH. Flush out both primary and domestic hot water circuits (see 4.3 Flushing the system )

6 2.2 Filling the System Check the properties of the water supply and install the appropriate treatment devices if the main water supply has a hardness rating more than 14.5 gpm (250 mg/l) in order to prevent scaling and eventual damage to the D.H.W primary heat exchanger. Use only clean tap water to fill the system. AIR VENT VALVE AIT AIR VENT VALVE PLUG AIR PUMP VENT VALV PLUG PUMP PUMP PUMP PLUG PLUG A pre-filtering system can be installed on the incoming water supply to help reduce impurities and limestone. This DPWH must have adequate water flowing through it whenever the burner is on. Failure to do this will damage the unit and void the warranty. Once the water pipes have been connected, close the gas cock and fill the system as follows: Check that the plug on the air vent valve attached to the circulating pump has been opened to allow air to escape from the system (Diag. 1). Open the main domestic water supply valve Open the manual filling tap R by turning counter-clockwise (Diag. 2) until pressure is in proper range and H20 is off display, CAUTION over pressurizing will cause the relief valve to open. Unscrew the brass plug on the circulating pump to remove any trapped air, check that the pump is rotating freely. Rotate the impeller with a screwdriver, then replace and retighten the brass plug when water starts to flow (Diag. 1). It may be necessary to use a cordless drill at times in order to ensure that the impeller rotates freely. 1 Diag Diag. 2 2 R M R M Before switching on the DPWH, purge air completely from the air vent valve positioned on the top of the exchanger (Diag. 3) Open the air vents on the radiators and monitor the air evacuation process. When water starts to flow out of the radiators, close the air vents Use the pressure gauge M (Diag. 2) to check that the system s pressure reaches the middle of the green area (equal to 17.4 PSI, Diag. 4). On completion, make sure that the filling tap R is closed If an auto feed is not present in the system, check the water pressure in the system. If the pressure has fallen, re-open the manual filling tap counter-clockwise until the H2O code disappears from the display. The ideal pressure should be the middle of the green area (1, 2 bar / 17.4 p.s.i.). Upon completion, close the manual filling tap (clockwise). 3 Diag PSI DiaFig 17.4 PSI PSI GREEN AREA 43.5 PSI Diag. 4

7 2.3 Filling the Condensate Trap The condensation trap must be filled with water prior to starting the DPWH. This process prevents flue gases from flowing back through the trap. The filling operation is carried out as follows (Diag. 5): Remove plug T and fill the trap S three quarters full with water Replace plug T and connect the drainpipe P into a condensate discharge trap conforming to current legislation Attention! It is recommended to clean the condensate trap after a few months operation in order to remove any deposits/residuals left after the first condensate passage within the DPWH. Residuals may interfere with the proper operation of the trap itself. 2.4 Ignition of the DPWH 1 Diag. 5 T S Once the system has been filled, proceed as follows: Check that the exhaust vent is free of obstructions and correctly connected to the DPWH Plug the DPWH into a 120V outlet Open the gas cock Press the ON/OFF switch and leave in the ON position, after a few seconds the circulating pump will start to run Press the top right button on the control display in order to setup the DOMESTIC MODE or HEATING MODE OR DOMESTIC/HEATING mode. The icons will appear and the display will light up (fixed light) to indicate that the DPWH is working On a call for heating or domestic the appropriate icon will flash, and the automatic ignition system will then light the burner. This operation is repeated 3 times. It may however be necessary to repeat the operation in order to eliminate air from the gas line. To repeat the operation, wait approximately three minutes before re-attempting to light the DPWH. To reset the DPWH press the main ON/OFF switch off and on again and repeat the lighting procedure. With the DPWH ignited, the system may still emit noises from the primary heat exchanger. This operation must be repeated until all the air has been removed and replaced with water. Ensure the pump is running whenever the DPWH is operating. If an auto feed is not present in the system, check the water pressure in the system. If the pressure has fallen, re-open the manual filling tap counter-clockwise until the H2O code disappears from the display. The ideal pressure should be the middle of the green area (1, 2 bar / 17.4 p.s.i.).upon completion, close the manual filling tap (clockwise). If the CO2 value at high fire does not correspond to the specified value shown in the installation manual, adjust screw V (Diag. 6) on the venturi clockwise to reduce the CO2 value or counter-clockwise to increase It. Make certain the unit is operating on high fire. fig.1 Diag. 6 V - 7 -

8 2.5 HEATING MODE Call For HEATING: Circulation pump is energized. The combustion fan blower purges the combustion chamber, then ramps to ignition speed (HZ) The ignition transformer provides a spark, gas valve opens, 3-way valve moves from domestic park location Ignition transformer drops out after flame is sensed (1.2 sec), gas valve remains open Combustion blower speed modulates (HZ) to meet the desired loop temperature. Venturi maintains combustion throughout range Limits and sensor are constantly monitored by the main control board. Sensors cause the unit to modulate to meet load. Tripping of any limit will cause the unit to shut down and display an error code Upon satisfying call, burner shuts down, unit post-purges, pump continues to operate for 180 seconds - 8 -

9 2.6 DOMESTIC MODE Request for the D.H.W. production: The flow switch closes Circulation pump is energized. The combustion fan blower purges the combustion chamber, then ramps to ignition speed (HZ) The ignition transformer provides a spark, gas valve opens, 3-way valve remains in domestic park position Ignition transformer drops out after flame is sensed (1.2 sec), gas valve remains open Combustion blower speed modulates (HZ) to meet the desired loop temperature. Venturi maintains combustion throughout range Limits and sensor are constantly monitored by the main control board. Sensors cause the unit to modulate to meet load. Tripping of any limit will cause the unit to shut down and display an error code Upon satisfying call, burner shuts down, unit post-purges, pump continues to operate for 90 seconds - 9 -

10 3. Maintenance (authorized personnel only) 3.1 General Warnings All maintenance operations must be carried out by professionally qualified personnel authorized by FLOWMAX. The frequency of DPWH maintenance is recommended to be carried out once a year. In order to guarantee the long life of the appliance and in accordance with the current gas safety regulations, only use original parts Before carrying out any type of maintenance operation, disconnect the appliance from the electrical supply and shut-off the gas supply. Warranty will not be honoured if recommended maintenance is not followed. 3.2 Dual Purpose Water Heater inspection In order to ensure that the DPWH operates efficiently and safely, it is recommended that the appliance be inspected by a professionally qualified technician at least once a year. The following operations should be carried out annually: Check that the condition of the gas seals and replace where necessary. Check that the condition of the water seals and replace where necessary. Visually inspect the condition of the combustion chamber and flame. Check that the combustion is correctly regulated, if necessary proceed to the section Commissioning the DPWH. Remove and clean any oxidation from the burner. Refer to section 6.7 in the installation manual. Check that the integrity and positioning of the washer on the cover of the burner. Refer to section 6.7 in the installation manual. Check that the primary heat exchanger and clean if necessary. Refer to section 6.7 in the installation manual. Check that the maximum and minimum modulation pressures and the modulation itself. Check the condition and operation of the ignition and gas safety systems. If necessary, remove and clean the scaling from the ignition and flame sensor electrodes. Pay particular attention when replacing them as they are at the correct gap from the burner. Refer to section 6.7 in the installation manual. Check that the heating safety systems: temperature limit safety thermostat, pressure limit safety device. Check that the pre-fill pressure of the expansion tank (see expansion tank rating plate). For safety reasons, periodically check the integrity and operation of the exhaust system. Check the connection to the main electrical supply and that it complies with what is stated in the DPWH s instruction manual. Check the electrical connections inside the control panel. Check the D.H.W flow rate and temperature. Check that the condensate drain system is working correctly, including any parts of the system outside the DPWH such as condensate collection devices along the length of the exhaust vent and/or any acid neutralising devices. Check that the condensate flows freely and that there are no exhaust fumes present within the appliance. Warranty will not be honoured if recommended maintenance is not followed

11 3.3 Draining the central heating system If the need arises to drain the system, this can be done as follows: Switch the system to HEATING mode and trigger a call for heat Once in heating mode unplug the power supply to the DPWH. Wait for the DPWH to cool down. Connect a hose to the system drain port located below the circulating pump and drain to a suitable drainage system. (Diag. 7). Open the system drain valve. Open the air vents on the radiators, starting with the highest and moving down the system to the lowest. When the system has been drained, close the radiator air vents and the drain valve. If only the DPWH needs to be drained, close the supply/return isolating valves on the heating circuit and open the drain valve located at the bottom of the DPWH on the pump manifold (Diag. 7). Diag. 7 fig.1 Draining the Domestic Hot Water System If there is a danger of freezing, the domestic hot water system should be drained. This can be done as follows: Close the main water supply valve. Open all the hot and cold water taps. On completion, close all the previously opened taps

12 4. Troubleshooting The self-diagnostics programmed within the main control board enables the unit to display an error code (8) (Diag. 8) that flashes when a problem arises with any number of components of the appliance. Some codes, namely the errors E01, E02, can be reset by pressing the ON/OFF switch/reset (1). Diag. 8 All the other codes cannot be reset as mentioned above. Only the intervention of a professionally qualified technician might lead to the solution of the problem. Error codes: E01 E02 E03 H2O E05 E06 E12 E16 E22 E35 E42 Ionization Electrode / Flame Sensor Lock Out, No Flame Detected Safety Thermostat Tripped / Air Pressure Switch Tripped Flue Gas Thermostat / Thermofuse Tripped Low Water Pressure Alarm Heating Sensor Malfunction Domestic Hot Water Sensor Malfunction Domestic Hot Water Storage Cylinder Sensor Malfunction Induced Draft Electric Fan Malfunction Parameter Programming Request Flame Sensor Malfunction Fan Control Board Malfunction

13 E01 IONIZATION ELECTRODE / FLAME SENSOR LOCK-OUT E01 IONIZATION ELECTRODE / FLAME SENSOR LOCK-OUT, FLAME DETECTED ENSURE THE GAS SUPPLY VALVE IS ON, CONFIRM GAS PRESSURE AT VALVE INLET 7-10 wc (17mbar- 25mbar) NG IS THE BURNER ON? CHECK FOR CORRECT POLARITY AT THE ELECTRICAL OUTLET IS THERE GAS PRESSURE CHECK THE GAS METER CORRECT POLARITY IS POLARITY CORRECT CHECK THE IGNITION TRANSFORMER FOR OPERATION 120v CHECK THE FLAME SENSOR μa (microamps). IS THE IGNITION TRANSFORMER FUNCTIONING CORRECTLY? REPLACE IGNITION TRANSFORMER REPLACE THE FLAME SENSOR IS THE FLAME SENSOR DAMAGED OR BROKEN CHECK THE SPARK IGNITOR FOR FUNCTION CHECK THE FLAME SENSOR CABLE REPLACE IGNITOR IS THE IGNITOR FUNCTIONING? CHECK THAT THE GAS VALVE IS OPERATING PROPERLY. IF VALVE IS T OPERATING PROPERLY - REPLACE VALVE REPLACE FLAME SENSOR IS SENSOR CABLE BROKEN REPLACE CABLE

14 With no ignition of the main burner, these might be the most likely causes: 1) THE INLET PRESSURE TO THE GAS VALVE MIGHT BE TOO LOW (OR TOO HIGH IN CASE OF LPG UNITS) Test and remedy: Verify the presence of gas from the main gas supply. F Procedure: a) Connect the tube from the manometer onto the pressure test Fig. 1 port on the inlet side of gas valve (inlet pressure test port) (Fig. 1) b) With the main gas cock open, verify if there is enough gas pressure. a. If the natrual gas pressure is not between 7-10 wc (17 mbar 25 mbar) for nat. gas, the gas valve will not operate properly. If this is the case, check the gas meter. b. If the liquid propane gas pressure is not between wc (25-34 mbar), check the propane gas regulator. Make certian the pressure does not exceed 13.5 wc (34 mbar). If this is the case, check the outlet pressure regulator of the LP tank. 2) DEFECTIVE GAS VALVE Test and remedy: Verify whether the gas valve is operating properly. Procedure: a) Connect the manometer tube onto the pressure test port of the inlet gas valve (low pressure test port). b) With the appliance in the off position, verify the gas pressure displayed on the manometer is between a range of 7-10 w.c. (17 mbar 25 mbar). a. Create a call for heat. b. Using a multimeter, verify 120v is present at the gas valve between the black & orange terminals. If 120v is present and the valve does not open the valve is defective, replace the gas valve. If 120v is not present check the cable that leads back to the main control board for continuity and replace if broken c. If the gas pressure is within range, create a call for heat. As the DPWH goes through it s ignition sequence, verify that the gas pressure changes. If the gas pressure does not drop, the gas valve is defective. At this stage, disconnect the voltage, close the gas cock and replace the gas valve. d. If the gas pressure drops, showing the gas valve has opened, proceed to the next step. 3) IGNITION TRANSFORMER DEFECTIVE OR T WORKING PROPERLY Test and remedy: Verify whether the ignition transformer is operating properly. Procedure: a) Listen for sparking of the electrode or view the spark through the view port on the vestibule of the primary heat exchanger if no sparking heard or viewed see below b) Close the gas cock. Using a multimeter, verify that 120v travels to the ignition transformer (Fig. 2) through the wire leads (Fig. 3) from terminal strip M5 on the main control board, between contacts 1 & 2 (Green & Black Wires). This voltage may be unstable at times. Fig. 2 Fig. 3 Fig. 4 a. If 120v is present, (Fig. 4) visually check that the ignition transformer does not arc to the metal plate it is mounted to. If this is the case, disconnect the voltage and replace the ignition transformer. If the ignition transformer does not arc onto the metal plate and cannot be heard after 3 attempts, the display will show a E01 error code. Disconnect the voltage and replace the ignition transformer

15 c) If voltage is not present at the ignition transformer, using a multimeter, verify that the terminal strip M5 on the main control board has high voltage between contacts 1 & 2 (Green & Black Wires) on call for heat. a. If 120v is present, disconnect the voltage and check the wire leads for continuity between the control board and the ignition transformer using a multimeter. b. If voltage is not present, disconnect unit power and replace the control board. 4) IGNITION ELECTRODE DEFECTIVE OR T WORKING PROPERLY Test and remedy: Verify whether the ignition electrode is operating properly Procedure: a) Unplug the power supply to the DPWH. b) Close the gas cock. c) Remove the ignition electrode using a Torx 20 screwdriver and make sure its ceramic parts are intact. In case it is damaged or broken, replace it. (Replace the gaskets if they are damaged). d) If the ignition electrode is not broken, verify the gap between the terminals of the ignition electrode is 3 ± 0.5mm. If this is not the case, adjust them to the correct gap and refit the ignition electrode onto the burner. (Diag. 9) (Replace the gaskets if they are damaged). Diag. 9 e) Check by means of a caliper, if there is the correct gap between the terminals of the ignition electrode and the main burner 8 ± 1mm. If it is not the case, adjust to the required gap. Refit to the burner. Should the ignitor be damaged, replace it with a new ignitor If, after all these operations, and the appliance does not light, verify if the ignition electrode arcs Procedure: a) Close the gas cock. b) Unplug the power supply to the DPWH. c) Remove the ignition electrode from the burner and leave it suspended in mid air while it is still connected to the ignition transformer. Make certain the electrode is properly grounded and does not make contact with any metallic surface. (Fig. 5) d) Plug in the power supply to the DPWH. e) Create a call for heat. The appliance will try to ignite. Replace the electrode if it does not create the required spark. (Replace the gaskets if they are damaged). (Extreme caution must be taken when holding the ignition electrode by the silicone tube due to the high current flowing through it when power is applied. ) Fig. 5 5) INSUFFICIENT COMBUSTION AIR Test and remedy: Verify the Combustion Air Supply is not plugged Procedure: a) Create a call for heat. If the appliance ignites with the door open or in the case of the Flowmax 170 series, the combustion air connection opened. Make certain that the combustion air pipe is not obstructed

16 If the burner actually ignites these might be the likely causes: 1) IONISATION ELECTRODE / FLAME SENSOR DEFECTIVE OR T WORKING CORRECTLY Test and remedy : Verify the ionisation electrode operates properly. Procedure: (see side figures) a) Disconnect the voltage from the main electrical supply. b) Close the gas cock. c) Remove the electrode using a Torx 20 screwdriver and verify it is intact. In case it is damaged or broken, replace it. (Replace the gaskets if they are damaged). d) If the ionisation electrode / flame sensor wire lead is not broken, by means of a caliper, check the ionisation electrode / flame sensor bears the right gap from the burner, i.e. 9 ± 1mm. If this is not the case, adjust the gap or replace the ionisation electrode / flame sensor. 2) WIRE LEADS OF THE IONISATION ELECTRODE / FLAME SENSOR DEFECTIVE OR DISCONNECTED Test and remedy: Verify the integrity of the wire leads. Procedure: a) Disconnect the voltage from the main electrical supply. b) Close the gas cock. c) Check visually the integrity of the wire leads and, if it is damaged or broken, replace it. (Replace the gaskets if they are damaged). d) If it is disconnected, connect the relevant wire leads. f) Plug in the power supply to the DPWH. g) Open the gas cock h) Create a call for heat. The appliance will try e) to ignite. f) Using a multimeter, verify the microamp reading (μa) for the ionisation electrode / flame sensor. In order to measure correctly, you must set your multimeter to read microamps and place your test leads in series with the ionisation electrode / flame sensor and the TF2 tab on electrode the main control board. Create a call for heat. The minumin reading should be between μa (microamps). 3) VENTURI T PROPERLY ADJUSTED Test and remedy: Verify the position of the venturi. Procedure: a) Create a call for heat. The appliance will ignite. Make certain the DPWH is operating on full fire. By means of a combustion analyzer, verify and adjust the CO2 reading according to the installation instructions. Refer to section 5.3 in the installation instructions. b) In order to adjust or tune the venturi, you must first locate the venturi (V) (Diag. 10) which is secured to the combustion blower. By means of a flat heat screwdriver turn the set screw located on the venturi clockwise or counter-clock quarter turn or until you find the correct CO2 reading, as stated in the installation manual. (Please note: All Flowmax models have different CO2 readings). Burner Diag. 10 Primary Heat Exchanger Heat Exchanger Premix Burner Unit B A Ionization Ionization Electrode / Flame Electrode/ Sensor Flame sensor Ignition Electrode

17 E02 SAFETY THERMOSTAT / AIR PRESSURE SWITCH TRIPPED E02 SAFETY THERMOSTAT 203 F (95 C) or AIR PRESSURE SWITCH TRIPPED (requires manual re-set of unit) SAFETY THERMOSTAT 203 F (95 C) AIR PRESSURE SWITCH CHECK THE SAFETY THERMOSTAT FOR CONTINUITY CHECK THE CONTACT BETWEEN TERMINALS 1 & 2 REPLACE THE SAFETY THERMOSTAT IS THERE CONTINUITY? CHECK THE FUSE & AIR INTAKE FOR BLOCKAGE IS THE CONTACT CLOSED CHECK AIR PRESSURE TUBE FOR MOISTURE CHECK FOR CORRECT WATER CIRCULATION IN SYSTEM CHECK FOR CORRECT SAFETY THERMOSTAT FUNCTIONING PROPERLY REPLACE THE PUMP IS THE PUMP WORKING? CHECK THE 3-WAY VALVE FOR CORRECT OPERATION REPLACE THE FLOW THROUGH HEAT EXCHANGER PART REPLACE THE 3-WAY VALVE IS 3-WAY VALVE MOVING? CHECK THE PLATE HEAT EXCHANGER IS THERE SUFFICIENT FLOW THROUGH THE HEAT EXCHANGER CHECK & CLEAN THE MAIN HEAT EXCHANGER

18 The likely causes are the following: 1) WATER CIRCULATION Test and remedy: Verify the circulating pump is operating correctly. Upon a demand for heating or domestic, the pump must operate immediately and stay on as long as the demand is present. If the pump does not operate, remove the brass screw at the center of the pump with a flat type screwdriver and spin the impeller by inserting the screwdriver into the opening. This action will cause the pump to rotate. If this action does not allow the pump to rotate with 120v present, replace the pump. If the pump still does not operate, verify that there is 120v present at the pump by means of a multimeter. If 120v is present at the pump, replace the circulating pump. If there is no 120v coming from the main control board, replace the main control board. 2) THE SAFETY THERMOSTAT IS DEFECTIVE Test and remedy: Verify the continuity of the thermostat by testing with a multimeter. In case of no continuity the safety thermostat is open, replace the thermostat. (Fig. 6) Fig. 6 3) THE SAFETY THERMOSTAT WIRE LEADS ARE DISCONNECTED Test and remedy: Verify visually and test with a multimeter if the electrical wiring is intact. Connect the wire leads to the safety thermostat. (Diag. 10) 4) THE DOMESTIC WATER FLOW SWITCH IS T WORKING CORRECTLY Test and remedy: Verify the burner switches off when there is no domestic demand. If that s not the case, remove the micro switch from the domestic water flow switch (Fig. 7) housing and verify the burner switches off. If the burner shuts off, replace the micro flow switch. If the appliance operates when the micro flow switch is not secured in place, replace the main control board. M1 Diag. Fig.3 10 light-blue brown PA TS 5) AIR INLET OR VENT PIPES OBSTRUCTED Test and remedy: Verify the status of the vent pipe. If it is obstructed with foreign objects or water, remove the obstruction before starting the unit. 6) THE AIR PRESSURE SWITCH IS DEFECTIVE OR T WORKING PROPERLY Fig. 7 Test and remedy: Verify if the air pressure switch is operating properly. Procedure: a) Using a multimeter, verify that the contact between 1 & 2 on the air pressure switch is closed (Diag. 11). If the contact is closed and the appliance still displays E02, check the safety thermostat (See point 2 above). If the contact is open, test with a multimeter terminals 1 & 2 on the pressure switch which are normally closed. If the pressure switch is open inspect and clear the exhaust vent pipe and pressure switch tube, if obstructed. If no obstructions are apparent, Use a manometer to check the vent pressure high fire. The maximum pressure allowed must be less than the value Diag. shown on the switch with the door closed. In both cases, if the Fig.4 11 error still exisits, disconnect the voltage and replace the air pressure switch. The maximum pressure sensed before the pressure switch opens is 2.14 mbar /.86 w.c. or 3.28 mbar / 1.32 w.c

19 E03 Flue Gas Thermofuse Tripped E F (102 C) THERMOFUSE FAILURE (N-RESETTABLE) 1 TIME ONLY REQUIRES PART REPLACEMENT CHECK FOR CONTINUITY AT THE THERMOFUSE HIGH FLUE TEMPERATURE (THE FLUE TEMPERATURE HAS EXCEEDED 205 F / 102 C). INSPECT AND CLEAN (IF REQUIRED) THE HEAT EXCHANGER COIL BEFORE REPLACING THE THERMOFUSE IS THERE CONTINUITY? CHECK THE CABLE FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINUITY REPLACE THE MAIN CIRCUIT BOARD

20 brown light-blue The likely causes are the following: 1) THERMAL EXHAUST FUSE DEFECTIVE Test and remedy: Verify the continuity of the thermal exhaust fuse Using a multimeter, check for continuity between the terminals on the thermal exhaust fuse. If there is no continuity, the flue gases have exceeded the temperature of 215 F 102 C and the primary heat exchanger is dirty and or obstructed. Make certain the cirulating pump is operating (See section no water circulation). If that is the case, clean the primary heat exchanger. Procedure: Fig. 8 a) Disconnect the voltage. b) Disconnect the wire leads on the thermal exhaust flue and apply a temporary bridge across the wires (Fig. 8 & Diag. 12). c) Apply voltage to the appliance. d) Make certain the cirulating pump is operating. (See section no water circulation) e) If error EO3 disappears and the burner ignites, clean the primary heat exchanger and replace the thermal exhaust fuse. f) If error E03 is still present, (Flowmax90 & 120 only) the thermal primary heat exchanger link may be open. See section 2 below. Procedure: a. Disconnect the voltage. b. Dis-assemble and clean the burner and primary heat exchanger as per the instructions outlined in the technical manual. Refer to section 6.7 Maintenance Operations Fig. 9 2) THERMAL PRIMARY HEAT EXCHANGER LINK (Flowmax90 & 120 Only) Test and remedy: Verify the continuity of the thermal primary heat exchanger link Using a multimeter, check for continuity between the terminals on the thermal primary heat exchanger link located on top of the primary heat exchanger. (Fig. 9). If there is no continuity, the flue gases have exceeded the temperature of 102 C / 215 F and the primary heat exchanger has been compromised. If this is the case, replace the primary heat exchanger. Refer to section 6.7 Maintenance Operations 3) ELECTRICAL CONNECTION DISCONNECTED Test and remedy: Check the electrical circuit visually for breaks or damage and test with a multimeter to verify continuity. Replace the wire leads, if damaged. TF TF max Fig.1 12 M

21 H20 Low Water Pressure Alarm H20 H20 Low Water Pressure Alarm WATER IN THE SYSTEM, INDICATES A LOW WATER SITUATION, UNIT IS OFF UNTIL RESOLVED CHECK THE WATER PRESSURE ON THE WATER PRESSURE GUAGE FILL THE SYSTEM USING THE MANUAL FILL VALVE OR AUTO FILL VALVE (IF USED) IS THERE SUFFICIENT WATER PRESSURE CHECK THE WATER PRESSURE GAUGE CALIBRATION REPLACE THE PRESSURE SWITCH IS THE WATER PRESSURE GAUGE CALIBRATED CHECK THE CABLE FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINUITY REPLACE THE MAIN CONTROL BOARD

22 The likely causes are the following: 1) INSUFFICIENT PRESSURE Test and remedy: Verify the pressure on the water pressure gauge. The pressure must be within the green area as displayed on the water pressure gauge, i.e. between 7.3 and 17.4 PSI (Diag. 13) or in the middle of the green area, when H2O is no longer displayed on LCD. If the pressure is insufficient, fill the system through the filling loop (Diag. 14) up to approximately 17.4 PSI, until H2O is no longer displayed on the LCD PSI 17.4 PSI 7.2 PSI GREEN AREA 43.5 PSI AIR VENT VALVE AIR VENT VALVE PLUG PUMP If the needle on the pressure guage is within the correct zone of the green area,and H2O is still displayed on the LCD, please check the following points. CAUTION over pressurising will cause the relief valve to open 1 Diag PUMP PLUG 2) DEFECTIVE WATER PRESSURE SWITCH Test and remedy: Verify the water pressure switch is operating properly. Procedure: a) Disconnect the voltage. b) Disconnect the wire leads to the water pressure switch P (Diag. 14 & Fig. 10) c) Apply a temporary bridge between the two terminals of the wire leads (Diag. 15). d) Reconnect power. If the error H2O is no longer displayed, replace the water pressure switch. If the error H2O is still displayed, see below. 3) DEFECTIVE WIRE LEADS OF THE WATER PRESSURE SWITCH Test and remedy: Verify the electrical connection between the main control board and the water pressure switch. Procedure: a) Disconnect the voltage. b) By means of a multimeter, verify the electrical connection between the main control board and the water pressure switch, if interrupted, disconnect the voltage and replace the wire leads. If H20 does not disappear from the display, disconnect the voltage and replace the main control board. 2 Diag. 14 Fig. 10 P R M PACQ: Water pressure switch 3Diag. 15

23 E05 Heating Sensor Malfunction E05 HEATING LOOP TEMPERATURE SENSOR FAILURE CHECK THE HEATING SENSOR VALUE WITH A MULTIMETER REPLACE THE HEATING SENSOR IS THE VALUE CORRECT? (I.E RESISTANCE VALUE 10 KOHM CHECK THE HEATING SENSOR CABLE FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINUITY REPLACE THE MAIN CONTROL BOARD

24 The likely causes are the following: a. HEATING SENSOR DEFECTIVE OR T WORKING PROPERLY Test and remedy: Verify the operation of the heating sensor. Procedure: a) Disconnect the voltage. b) Disconnect the wires from the heating sensor (Fig. 11). c) Set the multimeter to read Ohm s, apply the multimeter teminals to the heating sensor leads. You should have a value of Nominal resistance at 77 F / 25 C 10,000 Ohm, as per the table below. d) If the sensor does not provide the right data, as per the table, replace it. The error E05 will no longer appear on the display when voltage is connected. If the sensor is ok, verify the next point. Fig. 11 2) DEFECTIVE SENSOR Test and remedy: Verify the electrical connection between the main circuit board and the heating sensor. Procedure: a) Disconnect the voltage. b) Disconnect the wire leads of the heating sensor. c) Verify the continuity of the wire leads by means of a multimeter. If it is interrupted, replace the wire leads. The error E05 will no longer appear on the display when voltage is connected. If the wire leads is not interrupted, replace the main circuit board. MINAL RESISTANCE AT 25 C 10,000 Ohm Temp R NTC Temp R NTC Temp R NTC Temp R NTC Temp R NTC Temp R NTC

25 E06 D.H.W. Sensor Malfunction E06 D.H.W. TEMPERATURE SENSOR FAILURE CHECK THE D.H.W. SENSOR VALUE WITH A MULTIMETER REPLACE THE SENSOR IS THE VALUE CORRECT? (I.E RESISTANCE VALUE 10 KOHM CHECK THE D.H.W. SENSOR CABLE FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINUITY REPLACE THE MAIN CONTROL BOARD

26 The likely causes are the following: Diag. 16 b. DOMESTIC SENSOR DEFECTIVE OR T WORKING PROPERLY Test and remedy : Verify the reading of the domestic sensor. Procedure: a) By pressing the lower right button of the control panel (Diag. 16 button 2) for 7 seconds, the domestic output temperature (Diag. 16-3) will be displayed on the LCD screen. If the output temperature, measured by other means, is different from the displayed value, check the sensor resistance. b) Disconnect the voltage. c) Disconnect the wire leads of the domestic sensor (Fig. 12). d) Set the multimeter to read Ohm s, apply the multimeter teminals to the heating sensor leads. You should have a value of Nominal resistance at 77 F / 25 C 10,000 Ohm, as per the table above (see page 24). If the sensor does not provide the right data, as per the table, replace it. The error E06 will no longer appear on the display when voltage is connected. If the sensor is ok, verify the next point V 60Hz 2) DEFECTIVE WIRE LEADS OF THE DOMESTIC SENSOR Test and remedy: Verify the electrical connection between the main P.C.B. and the Domestic sensor. Procedure: a) Disconnect the voltage. b) Disconnect the wire leads of the domestic sensor. c) By means of a multimeter, please verify the continuity of the wire leads. If it is interrupted, replace the wire leads. The error E06 will no longer appear on the display when 120v is connected. If the wire leads is not interrupted, replace the main control board. Fig

27 E12 D.H.W. Storage Tank Sensor Malfunction E12 D.H.W. Storage Tank Sensor Malfunction CHECK THE STORAGE SENSOR VALUE WITH A MULTIMETER REPLACE THE STORAGE TANK SENSOR IS THE VALUE CORRECT? (I.E RESISTANCE VALUE 10 KOHM AT 25 C CHECK THE STORAGE SENSOR CABLE FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINUITY REPLACE THE MAIN CONTROL BOARD

28 The likely causes are the following: 1) DOMESTIC (STORAGE) SENSOR DEFFECTIVE OR T WORKING CORRECTLY Test and remedy: Verify the operation of the domestic 3 sensor by pressing lower right button Diag. 16 Procedure: d) By pressing the lower right button of the control panel (Diag. 16 button 2) for 7 seconds, the domestic temperature (Diag.16 3) will be displayed on the LCD screen. If the tank temperature, measured by other means, is different from the displayed value, check the sensor resistance. 120V 60Hz e) Using a multimeter, verify the value of the domestic sensor is consistant with the data provided on the table Nominal resistance at 77 F / 25 C 10,000 Ohm (see p.24). If the sensor is working properly, E12 will no longer appear on the display. If E12 continues to appear even after the sensor has been replaced, replace the main contol board

29 E16 Electric Fan Malfunction E16 E16 Combustion blower Malfunction INDUCED FAN FAILURE CHECK THE OPERATION OF THE FAN REPLACE THE FAN IS THE FAN OPERATING CHECK THE FAN CONTROL CABLE FROM THE MAIN CONTROL BOARD FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINUITY REPLACE THE MAIN CONTROL BOARD

30 M10 The likely causes are the following: 1) COMBUSTION BLOWER DEFECTIVE OR T WORKING PROPERLY Test and remedy: Verify the proper operation of the combustion blower. Procedure: a) Disconnect the wire leads from the combustion blower (Dia. 17 CABLE 1) & (Fig 13). The combustion blower will operate at the maximum speed, if this is the case replace the fan control board (Fig. 14) and the wire leads between that board and the combustion blower. b) If the combustion blower does not activate, ensure 120v is present at the combustion blower. Procedure: a) Disconnect the main wire leads (POWER) of the combustion blower (Dia. 17 CABLE 1) & (Fig 13). b) Using a multimeter, test for 120v on the hot and neutral terminals that feed the combustion blower. In case there is no voltage, verify the 2A fuse, (Fig. 15) which is in series is not open If this is not the case, replace the combustion blower. Fig. 13 Fig. 14 Fig. 15 Diag. 17 Fig.1 PRINTED CIRCUIT BOARD DIGITECH - SM20021 M1 M2 M3 PRINTED CIRCUIT BOARD KOND Fan DT Control - SK11003 Board COD LA M5 Main Control Board M4 M6 M7 POWER FAN CAVO Cable 11 M8 M8 +24V HS PWM GND M9-30 -

31 E22 Parameter Programming Request E22 PARAMETER PROGRAMMING REQUEST (THIS CODE APPEARS ON INITIAL POWERING WHEN A MAIN CONTROL BOARD IS CHANGED) MICROPROCESSOR MEMORY IS LOST REPROGRAM PARAMETER SET PARAMETER AS FOUND IN INSTALLATION MANUAL FOR SPECIFIC MODEL AND CAPACITY

32 The likely causes are the following: 1) LOSS OF MEMORY OF THE MICROPROCESSOR OF THE MAIN CIRCUIT BOARD. Test and remedy : Verify all parameters on the main circuit board are as per the original settings. If it is not the case, re-program the unit as per the table included in the technical manual. If the problem still exisits, disconnect the voltage and replace the main circuit board (Fig. 16), as it might have been affected by an irreparable problem with the memory of the micro-processor. When confirming programming make certain you are entering the correct unit capacity and values as the the model you are servicing. (Refer to section 5, Regulating the Appliance) Fig. 1 Fig

33 E35 Flame Detection Malfunction E35 Flame Detection Malfunction CHECK THE OPERATION OF THE IONIZATION ELECTRODE / FLAME SENSOR REPLACE THE IONISATION ELECTRODE / FLAME SENSOR IS THE IONISATION ELECTRODE / FLAME SENSOR DEFECTIVE CHECK THE IONISATION ELECTRODE / FLAME SENSOR CABLE FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINUITY REPLACE THE MAIN CONTROL BOARD

34 The likely causes are the following: 1) IONIZATON ELECTRODE / FLAME SENSOR DEFECTIVE OR T WORKING CORRECTLY Test and remedy: Verify the ionisation electrode / flame sensor is operating properly. Procedure: (see side figure) a) Disconnect the voltage from the main electrical supply. b) Close the gas cock. c) Remove the ionisation electrode / flame sensor and verify its integrity. In case it is damaged or broken, replace it. (Replace the gaskets if they are damaged). d) If the ionisation electrode / flame sensor is not broken, disassemble the burner and check by means of a caliper. The ionisation electrode / flame sensor should bear the correct gap to the burner of 9mm ± 1mm. If it is not the case, adjust the gap. If the problem is still exists, replace the ionisation electrode / flame sensor, or finally the main control board. Burner Premix Burner Unit B Primary Heat Exchanger A tyyg gfhg Ionization Electrode / Electrode Flame Sensor / Flame sensor Ignition Electrode Flame sensor Electrode

35 E42 Fan Control Board Malfunction E42 FAN CONTROL BOARD FAILURE CHECK THE CONNECTION CABLE BETWEEN THE MAIN CONTROL BOARD AND THE FAN FOR CONTINUITY OR BREAKS REPLACE THE CABLE IS THERE CONTINIUTY REPLACE THE MAIN CONTROL BOARD

36 M10 The likely causes are the following: 1) THE FAN CONTROL BOARD IS DEFECTIVE OR T WORKING CORRECTLY Test and remedy: Verify the proper running of the fan contol board. Procedure: a) Disconnect the voltage. b) By means of a multimeter, verify the continuity of the wiring wire leads between the main control board and the fan control board (Diag.18 Cable 2) & (Fig. 17). If the electrical connection is interrupted, replace the wire leads (Cable 2). If the electrical connection is not interrupted, replace the fan contol board (Fig. 17). Fig.1 Diag. 18 PRINTED CIRCUIT BOARD DIGITECH - SM20021 M1 M2 M3 PRINTED CIRCUIT BOARD KOND Fan DT Control - SK11003 COD LA Board M5 M4 Main Control Board M6 M7 CAVO 2 Cable 2 POWER FAN CAVO Cable 1 1 M8 M8 +24V HS PWM GND M9 Fig

37 - 37 -

38 - 38 -

39 - 39 -

40 - 40 -

41 - 41 -

42 Function codes Diag Each time flashing numbers are displayed on the LCD display (see Diag. 19 3), a relevant mode is activated. All functions are disabled upon the termination of their specific function. fig Flue Test Function Active (Chimney-Sweeper) Description Pressing the service button for 7 seconds (Diag. 19 button 2) activates the flue test function. Pressing the DPWH ON/OFF switch deactivates the function (Diag.19 button 1). The flue test function operates the DPWH at the maximum heating pressure for 15 minutes without any modulation. The function is useful for combustion testing. 08 Frost Protection Central heating circuit Description This function is activated when the heating sensor senses a temperature of 5 C / 41 F. The DPWH operates at minimum gas pressure with the 3-way diverter valve in the heating position. This function is deactivated when the temperature detected by the sensor when it reaches 30 C / 86 F. 09 Frost Protection D.H.W. circuit Description This function is activated when the sensor senses a temperature of 4 C / 39 F. The DPWH operates at minimum gas pressure. The 3-way diverter valve closes in the domestic position and heats the D.H.W. circuit. This function is deactivated when the D.H.W. storage cylinder sensor detects a temperature of 8 C / 46 F. 13 Frost Protection D.H.W. circuit for storage DPWH Description This function is activated when the sensor senses a temperature of 4 C / 39 F. The DPWH operates at minimum gas pressure. The 3-way diverter valve closes in the domestic position and heats the D.H.W. circuit. This function is deactivated when the D.H.W. storage cylinder sensor detects a temperature of 8 C / 46 F Legionella Prevention Function Description This function is activated for storage DPWH only. It comes into operation every 7 days. It brings the hot water temperature in the storage cylinder up to 60 C / 140 F or whatever temperature is set for hot water. 31 Incompatible Remote Control Description This function is activated when the remote control connected is not compatible with the printed circuit board

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

Columbia Boiler Company

Columbia Boiler Company EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net

More information

DOMESTIC HOT WATER Follow operational sequence

DOMESTIC HOT WATER Follow operational sequence DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents

More information

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents

More information

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2004-28 TSG-SOLO-9/04 Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL MODULE DISPLAY -

More information

User Manual for model

User Manual for model User Manual for model RKA 24 /20 Wall mounted storage combi boiler premix condensing boiler CE 0694 Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate RKA 24.20 - RAD - ING - MAN.UT - 1309.1

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 11/10/08 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

Tankless Water Heater

Tankless Water Heater Tankless Water Heater USER S INFORMATION MANUAL Models WGRT**150 / WGRT**199 / WGRTC**199 **A suffix of LP denotes propane gas **A suffix of NG denotes natural gas NOTICE: Westinghouse reserves the right

More information

New Power Vented Rheem FVIR Tanks

New Power Vented Rheem FVIR Tanks Technical Bulletin B06-08 Sept 26/ 2006 New Power Vented Rheem FVIR Tanks In the coming weeks new power vented FVIR tanks will be arriving in the field from our tank manufactures. We are supplying some

More information

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev. 95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler Control Manual And Troubleshooting Guide P/N 24000604, Rev. C [04/09] WARNING! Revise boiler control parameters only if you fully understand the

More information

User Manual for model

User Manual for model User Manual for model RKA 24/8 RKA 24 RKA 28 RKA 34 Wall mounted storage combi boiler premix condensing boiler User instruction CE 0694 RKA 24.8_24_28_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO

More information

Universal Fire Tube Boiler Wall Mount Models

Universal Fire Tube Boiler Wall Mount Models Universal Fire Tube Boiler Wall Mount Models USER S INFORMATION MANUAL Models WBRU**80W / 100W / 120W / 140W / 175W / 199W **NG denotes Natural Gas Model, LP Denotes Propane Model Heat Exchanger Bears

More information

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This

More information

VSL II QUICK START GUIDE

VSL II QUICK START GUIDE This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER

More information

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Control manual and troubleshooting guide

Control manual and troubleshooting guide Control manual and troubleshooting guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER! Revise boiler control parameters only if you fully understand the purpose and result of the changes.

More information

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE TROUBLESHOOTING INTEGRATED FURNACE Failure to read and follow all instructions carefully before installing or operating this control, could cause personal injury and/ or property damage. 50A55 INTEGRATED

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

HX Field Replacement Kit

HX Field Replacement Kit Quantity Kit Part Number Description PE 110 Natural Gas Stainless Steel Condensate Pan PT 110 Natural Gas Polypropylene Condensate Pan Model PE 110 LP Stainless Steel Condensate Pan PT 110 LP Polypropylene

More information

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by

More information

VSL II QUICK START GUIDE

VSL II QUICK START GUIDE This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER

More information

QHT Manual for: SU-2A Gas Burner

QHT Manual for: SU-2A Gas Burner 1 QHT Manual for: SU-2A Gas Burner 50,000 BTU/H to 250,000 BTU/H The burner shall be used only with NATURAL GAS or LP GAS. Warning: If the following instructions are not followed exactly, a fire or explosion

More information

Energy-Efficient, Environmentally-Friendly Heating Solutions. Baxi Luna HT Residential Troubleshooting Guide

Energy-Efficient, Environmentally-Friendly Heating Solutions. Baxi Luna HT Residential Troubleshooting Guide Energy-Efficient, Environmentally-Friendly Heating Solutions Baxi Luna HT Residential Troubleshooting Guide WARNING! THIS DOCUMENT IS INTENDED ONLY AS AN EDUCATIONAL TOOL THIS TROUBLESHOOTING GUIDE, AND

More information

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Gas Fired Residential Combi Boiler Floor and Wall Mount Models Gas Fired Residential Combi Boiler Floor and Wall Mount Models USER S INFORMATION MANUAL Models WBRC**140W WBRC**199W WBRC**140F WBRC**199F ** NG Refers to Natural Gas Operation LP Refers to Propane Gas

More information

A/23 MFFI - A/27 MFFI

A/23 MFFI - A/27 MFFI A/23 MFFI - A/27 MFFI G.C.N. 47-6-0 / 47-6-2 Servicing Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of

More information

MAINTENANCE AND SERVICE GUIDE

MAINTENANCE AND SERVICE GUIDE c Dimensions MAINTENANCE AND SERVICE GUIDE System II 80 and 100 Central Heating Fanned Flue Boiler Sizes in mm Flue types: C 12 or 42: horizontal C 32 xx: vertical concentric C 32 xy: Twin flue Boiler

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Residential Gas Hybrid Water Heater

Residential Gas Hybrid Water Heater Residential Gas Hybrid Water Heater USER S INFORMATION MANUAL WGRGH20NG75F / WGRGH20NG76F / WGRGH20NG100F WGRGHNG75F / WGRGHNG76F / WGRGHNG100F Models* *A suffix of LP denotes propane gas NOTICE: Westinghouse

More information

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER Servicing Instructions Type C Boilers G.C.N: 4-6-0 47-6-08 47-6-09 47-6-3 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of Parts 3.2

More information

Hot Surface Ignition (HSI) System Booklet

Hot Surface Ignition (HSI) System Booklet Hot Surface Ignition (HSI) System Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com 010298MFM/abe

More information

Figure 10 or Figure 6

Figure 10 or Figure 6 SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-45637-00 and 238-48933-00 (Replaces pg. 32 (238-45637-00) or pg. 28 (238-48933-00) in Wiring Diagram Honeywell A B C VERY HO HO LOW Figure 10 or Figure 6 238-48214-00B

More information

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS 50M56-743 Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD

More information

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler rinnai.us 1-800-621-9419 CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler Wall-Mounted, Gas-Fired Boiler For the Conversion from Natural Gas (NG) to Liquid Propane Gas (LPG) MODELS M060C M090C M120C

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A66-743 Integrated Furnace Control Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL

More information

Bosch 80% AFUE Gas Furnace BGS80 Model

Bosch 80% AFUE Gas Furnace BGS80 Model Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018

More information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG

More information

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions Fired Humidifier SKG Series SKG - 180301 Standard Combustion Adjustment SKG Fired Humidifier All installation work must be carried out by suitably qualified personnel and must conform to local codes and

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION R SERIES 35-61 24 VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay F-35-61 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge

More information

Service Manual Model 3163

Service Manual Model 3163 Service Manual Model 3163 Contents Important Safety Information.......... 1 Specifications.................. 2 General Information.............. 2 Direct Vent Requirements........... 2 Propane System................

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A65-843 Universal Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS 21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE

More information

Indirect gas-fired air heater

Indirect gas-fired air heater Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners 1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):

More information

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler ClearFire Model CFH Horizontal Steam Boiler Startup Guide 750-293 www.cleaverbrooks.com Improper installation, adjustment, service, or maintenance can cause equipment damage, personal injury, or death.

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1

More information

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS 50T35-743 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-51012-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest w ater heaters on

More information

Condensing Models. On-Demand Water Heater Service Handbook

Condensing Models. On-Demand Water Heater Service Handbook Condensing Models On-Demand Water Heater Service Handbook MODELS: 240 Indoor (T-H3J-DV) 240 Outdoor (T-H3J-OS) 340 Indoor (T-H3S-DV) 340 Outdoor (T-H3S-OS) 540 Indoor (T-H3-DV) 540 Outdoor (T-H3-OS) Series

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 21M51U-843 Universal Integrated Two-Stage 120Volt Hot Surface Ignition Control Kit INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters MADE IN ITALY THE EXPERT of stainless steel condensing heating systems ECO FRIENDLY wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters AISI 6Ti

More information

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA) R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215) National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215) 244-1400 1-800-523-7138 Fax: (215) 639-1674 14299575-10/29/2014 NOTE: These installation and maintenance instructions should be left

More information

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA Navien America Inc. Specification Details for the Navien models: CR-210 CR-210A For Indoor Installation Only For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA,

More information

TAHITI CONDENSING KR 55 - KR 85

TAHITI CONDENSING KR 55 - KR 85 IST 03 C 351-01 TAHITI CONDENSING KR 55 - KR 85 GB INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully. They will

More information

Model 60200FR Gas Primary Control Data Sheet

Model 60200FR Gas Primary Control Data Sheet Programmable, Microprocessor Based Gas Burner Primary Controls On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information Fault

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

ML180UH SERIES GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING 2017 Lennox Industries Inc. Dallas, Texas, USA 506525-01 04/2017 Supersedes 10/2015 ML180UH SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

PrecisionTemp Shower-Mate

PrecisionTemp Shower-Mate Shower-Mate Instantaneous Gas Water Heater Installation and Operating Instructions The Shower-Mate is a power vented automatic instantaneous water heater designed to be installed in ventilated marine applications.

More information

50A Integrated Furnace Control

50A Integrated Furnace Control 50A56-956 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY

More information

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6 GAS CONTINUOUS FLOW WATER HEATERS INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6 2 INSTALLATION INSTRUCTIONS

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA 506737-01 04/2017 Supersedes 03/2017 USER S INFORMATION MANUAL EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance

More information

CE & UL Version Error messages & Troubleshooting Electric and Gas Combi. Serial-No. / date

CE & UL Version Error messages & Troubleshooting Electric and Gas Combi. Serial-No. / date CE & UL Version Error messages & Troubleshooting Electric and Gas Combi 2010/02/23 SEV/KA Model Electric: from ESC 615 07020584 / May 2007 ESC 620 07020584 / May 2007 ESC 115 07020584 / May 2007 ESC 120

More information

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION R SERIES 35-703 120 VAC Microprocessor-Based Intermittent Pilot Ignition Control F-35-703 July 2016 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

BAXI LUNA 310 Fi TECHNICAL INFORMATION

BAXI LUNA 310 Fi TECHNICAL INFORMATION BAXI LUNA 310 Fi TECHNICAL INFORMATION Baxi Luna Wall-Hung Boiler Commissioning Checklist Please attend to each of these items before calling for technical assistance Venting connected and secure Power

More information

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH 33-44-50 CAH 49-54-70 CAH VARIABLE SPEED AIR HANDLERS DIMENSIONS... 3 TECHNICAL SPECS... 4 INSTALLATION DON TS... 5 INSTALLATION DO S... 6 FREEZE STAT REQUIRED

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

Zehnder ComfoInline Heater

Zehnder ComfoInline Heater Zehnder ComfoInline Heater Specifications and Installation Guidelines This unit complies With CSA and UL SDHR5-1.5K120V1P-CIRO17-OTDD-OEMZ standards SDHR6-2.5K220V1P-CIRO17-OTDD-OEMZ SDHR7-3.5K220V1P-CIRO17-OTDD-OEMZ

More information

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER) 100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER) WARNING If the information in these instructions is not followed exactly, a

More information

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE - SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN VC3ED ML-137013 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly

More information

TO DO IF YOU SMELL GAS

TO DO IF YOU SMELL GAS User's Information Document 1125B User's Information Manual for Endurance EBP Series Modulating Combination Boiler (natural or propane gas) EDP Series Modulating Hydronic Boiler (natural or propane gas)

More information

SPECIFICATIONS - NIKE

SPECIFICATIONS - NIKE Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks

More information

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E Instantaneous wall-hung with open chamber boilers Small wall-mounted open chamber, conventional flue instant boiler. General features. is a wall-mounted, open combustion chamber, conventional flue generator

More information

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL Figure 1 Series 9 Intermittent Pilot Ignition Control Application The Series 9 Intermittent Pilot Ignition Control is a microprocessor

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

This document was created with FrameMaker 4.0.4

This document was created with FrameMaker 4.0.4 This document was created with FrameMaker.0. WELCOME TO TODAY S GENERATION OF COMFORT Congratulations! Your new, higher efficiency gas furnace is a sound investment which will reward you and your family

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5 4 ±0.5 12.0 Servicing 12.2 Annual Servicing Inspection (Cont) Flame Sensing 5 ±1 10 ±1 Position Fig. 45 Spark Ignition 5. Remove the clip securing the gas feed pipe to the air/gas venturi. Disconnect the

More information

Marquis User s Manual

Marquis User s Manual Marquis User s Manual Model TWH200 / TWH200LP Gas Condensing Water Heater Natural Gas(NG) TWH200 Liquid Propane Gas (LP) TWH200LP WARNING Read the Installation Manual carefully and be sure that your water

More information

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD. 2017 Lennox Industries Inc. Dallas, Texas, USA 506897-01 04/2017 Supersedes 10/2015 EL280DF SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

MILLA ELECTRIC FIREPLACE

MILLA ELECTRIC FIREPLACE MILLA ELECTRIC FIREPLACE MODEL NO. 064-3177-0 ASSEMBLY INSTRUCTIONS Toll-free: 1-888-670-6684 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this manual for

More information