Product Data. Features/Benefits. 40QA Cooling Only and Heat Pump Ceiling Suspended Fan Coil. 1 1 / 2 to 5 Nominal Tons

Size: px
Start display at page:

Download "Product Data. Features/Benefits. 40QA Cooling Only and Heat Pump Ceiling Suspended Fan Coil. 1 1 / 2 to 5 Nominal Tons"

Transcription

1 Product Data 40QA Cooling Only and Heat Pump Ceiling Suspended Fan Coil 1 1 / 2 to 5 Nominal Tons The 40QA Energy-Efficient Ceiling Suspended fan coil incorporates innovative technology to provide reliable cooling and heating performance. Built into these units are features most desired by the industry, including: SEER (Seasonal Energy Efficiency Ratio) ratings of up to 12.0 when matchedwithductfreesystem Fan Coils. All models are UL (Underwriters Laboratories); UL, Canada; ARI and CEC (California Energy Commission) listed. A wide range of accessories is available to meet a variety of installation requirements. The 40QA series is ideal for applications where there is no available space above the ceiling or the ceiling height is restricted. Features/Benefits Technology and components A high-efficiency, four-row heat exchanger has mechanically expanded copper tubes with continuous aluminum fins. The coil connections are made of brass. Fan motor The direct-drive fan has a three-speed permanent split capacitor motor with built-in thermal protection, regulated by an electronic thermostat. The motor is installed on anti-vibration mounts. The fan blade design ensures uniform airflow through the heat exchanger. Air distribution Air distribution provides individual comfort with the features of horizontal air sweep and vertical deflectors. The special design of air distribution ensures rapid blending of the supply and room air. Conditioned air can be Copyright 2004 Carrier Corporation Form 40QA-1PD

2 directed in numerous positions, then evenly distributed throughout the room. Return air enters the unit through the bottom back of the unit. It is then cleaned by an easily removable, washable filter. Controls A choice of three different thermostats are available, suitable for installation on a wall. The solid-state electronic thermostat is available in Slim Line, Flat Stat, and a programmable NP-thermostat. Thermostat features include: Three-speed manual setting Automatic changeover Secure operation If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. Fast installation Carrier s compact systems take only a few hours to install only wire and piping need to be run. The fast and easy installation ensures minimal disruption to customers in the home or workplace. This Carrier advantage is especially beneficial in retrofit situations. Built-in reliability Carrier split system units are designed to provide years of trouble-free operation with features such as freeze protection and 24-volt controls. Flexibility A variety of accessories help meet system requirements and weather considerations. Available accessories include: Slim Line thermostat, Flat Stat thermostat, NP - thermostat, condensate pump, fresh air intake kit, power vent fan for fresh air intake, and remote room sensor. Order and install these accessories separately. Table of contents Features/Benefits ,2 Model Number Nomenclature ARI Capacity Ratings ,4 Physical Data Field-Installed Accessories Dimensions Performance Data Electrical Data Typical Wiring Schematics Typical Piping and Wiring Controls Guide Specifications ,15 Model number nomenclature 40 QAB Indoor Fan Coil Unit Type QAB = Under Ceiling Cool Only QAE = Under Ceiling Heat Pump Voltage 311 = 208/ = 208/ = 208/ Nominal Capacity 024 = 1 1/2, 2 Tons 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons *The 40QAB/AQE024 unit can be reconfigured to a 40QAB/QAE / 2 ton unit by using a different motor speed fan tap. 2

3 ARI* capacity ratings COMBINATIONS PISTON SIZE CHARGE COOLING ONLY UNDER CEILING INDOOR 40QAB QAB QAB QAB QAB QAB OUTDOOR ARI CAPACITY (Btuh) ACCURATER PISTON NO. CHARGE (lb) (Note 1) 38HDC , HDL , HDC , HDL , HDC , HDL , HDC036-3, 5, 6 34, HDL , HDC048-3, 5, 6 47, HDL , HDC060-3, 5, 6 58, HDL , INDOOR OUTDOOR ARI CAPACITY COOLING (Btuh) HEAT PUMP UNDER CEILING ARI CAPACITY HEATING (Btuh) ACCURATER PISTON INDOOR ACCURATER PISTON OUTDOOR CHARGE (lb) (Note 1) 40QAE QR-018C-3 19,000 17, QR-024C-3 24,000 22, QAE QR-030C-3 30,000 28, QR-036C-3, 5, 6 33,400 33, QAE QR-048C-3, 5, 6 48,000 45, QAE QR-060C-3, 5, 6 58,000 57, HEAT/COOL UNDER CEILING (Cooling With Electric Heat) INDOOR 40QAE QAE QAE QAE OUTDOOR ARI CAPACITY (Btuh) ACCURATER PISTON NO. CHARGE (lb) (Note 1) 38HDC , HDL , HDC , HDL , HDC , HDL , HDC036-3, 5, 6 33, HDL , HDC048-3, 5, 6 46, HDL , HDC060-3, 5, 6 57, HDL , *ARI Air Conditioning and Refrigeration Institute. The 024 size unit shown is configured as an 018 size unit by changing the motor speed fan tap plug. NOTES: 1. Charge is based on 25 ft of interconnecting tubing. Charge may need to be added for longer runs. 2. Cooling units shipped with a full charge. Heat pumps are shipped with a holding charge. 3. For expanded ratings see matching condenser product data catalog. 4. Air entering evaporator 80 F dry bulb. Air entering evaporator 72 F wet bulb. 5. Rated and certified in accordance with ARI Standards 210/240 and

4 ARI* capacity ratings (cont) 40QAB018* 40QAB024 40QAB024 40QAB036 40QAB048 40QAB060 40QAE018* 40QAE024 40QAE036 40QAE048 40QAE060 LEGEND ARI Air Conditioning and Refrigeration Institute dba Decibels on the A scale SOUND DATA UNDER CEILING FAN COILS (A Weighted) SOUND SOUND FAN SOUND POWER DATA OCTAVE BAND (dba) PRESSURE (dba) POWER (dba) SPEED High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low *The 40QAB/QAE018 unit is a 40QAB/QAE024 unit using a different motor speed fan tap plug. Field reconfigured for 18,000 Btuh. NOTES: 1. Sound levels are taken in accordance with ARI Sound Standard Sound Pressure data is measured at 1 m from the unit. 4

5 Physical data 40QAB018* 40QAB024 40QAB036 40QAB048 40QAB060 40QAE018* 40QAE024 40QAE036 40QAE048 40QAE060 NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) MOISTURE REMOVAL (pts/hr) REFRIGERANT TYPE R-22 R-22 R-22 R-22 R-22 R-22 R-22 R-22 R-22 R-22 METERING DEVICE (Note 1) AccuRater AccuRater AccuRater AccuRater AccuRater AccuRater AccuRater AccuRater AccuRater AccuRater CHARGE (lb) (Note 2) Note INDOOR FAN (Direct Drive) High Rpm/Cfm 862/ / / / / / / / / /1600 Med Rpm/Cfm 690/ / / / / / / / / /1220 Low Rpm/Cfm 552/ / / / / / / / / /1040 Air Throw ft (high fan) Watts Quantity Hp 1/ 16 1/ 16 1/ 16 1/ 6 & 1 / 16 1/ 6 1/ 16 1/ 16 1/ 6 1/ 6 & 1 / 16 1/ 6 BLOWER WHEEL Quantity Size (in.) 6x8 6x8 6x8 6x8 6x8 6x8 6x8 6x8 6x8 6x8 INDOOR COIL DATA Face Area (sq ft) No. of Rows FPI Circuits Filters (Cleanable) Quantity Note Note 4 6 Size (in.) 12 x x x 8.7 Note 4 12 x x x x 8.7 Note 4 12 x 8.75 Refrigerant Lines Connection Type Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare Liquid Line (in.) 3 / 8 OD 3 / 8 OD 3 / 8 OD 3 / 8 OD 3 / 8 OD 3 / 8 OD 3 / 8 OD 3 / 8 OD 3 / 8 OD 3 / 8 OD Vapor Line (in.) 5 / 8 OD 5 / 8 OD 3 / 4 OD 3 / 4 OD 3 / 4 OD 5 / 8 OD 5 / 8 OD 3 / 4 OD 7 / 8 OD 7 / 8 OD Max Length, Lift & Drop Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 CONDENSATE DRAIN Outside Dia (in.) (Malepipethd)(Note6) 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 CONTROLS (Solid State) Wall Thermostat (Required) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Freeze Protection Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Defrost Method N/A N/A N/A N/A N/A Time/Temp Time/Temp Time/Temp Time/Temp Time/Temp Fan Speeds H/M/L/Auto H/M/L/Auto H/M/L/Auto H/M/L/Auto H/M/L/Auto H/M/L/Auto H/M/L/Auto H/M/L/Auto H/M/L/Auto H/M/L/Auto Control Voltage 24-v 24-v 24-v 24-v 24-v 24-v 24-v 24-v 24-v 24-v System Voltage 208/230 v 208/230 v 208/230 v 208/230 v 208/230 v 208/230 v 208/230 v 208/230 v 208/230 v 208/230 v AIR SWEEP Horizontal Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Vertical Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Finish Note 7 Note 7 Note 7 Note 7 Note 7 Note 7 Note 7 Note 7 Note 7 Note 7 *The 40QAB/QAE018 fan coil is a 40QAB/QAE024 unit using a different motor speed fan tap. Refer to installation instructions for details. Valve connection size is 3 / 4 -in. Recommended line size is 7 / 8 -in. With recommended thermostat. NOTES: 1. Metering device located in the indoor unit ft of refrigerant lines. Heat pump units are shipped with a holding charge. 3. Single-phase unit 7.5 lb, 3-phase unit 8.7 lb. 4. 4pieces10ft-6in.x8ft-7in.and2pieces12ftx8ft-7in. 5. See matching condenser for line lengths. 6. Flexible tubing ( 5 / 8 in.) required when optional condensate pump is used. 7. GM Motorhome White with black trim. 5

6 Field-installed accessories Slim Line thermostat is a specially designed thermostat for Duct-Free Systems that incorporate 3-speed control, programmability, autochangeover, backlight, locking keypad and a large LCD display. (Slim Line thermostats can only be used on cooling only, heat pumps and heat/cool systems.) Flat Stat thermostat is a specially designed thermostat for Duct-Free Systems that incorporates 3-speed control, programmability, autochangeover, backlight, locking keypad and a large LCD display that is mounted flush to the wall. (Flat Stat thermostats can only be used on cooling only and heat/cool systems.) NP - thermostat is a specially designed thermostat for Duct-Free Systems that incorporates 3-speed control, (Monday through Friday - Saturday - Sunday) programmability, autochangeover, backlight, locking keypad and a large LCD display. (NP - thermostats can only be used on cooling only and heat/cool systems.) Fresh air intake kit provides for a variable amount of outdoor air to be mixed with the conditioned air. Power vent fan for fresh air intake provides up to 30% of outdoor air to be supplied to the conditioned space (requires intake kit). Remote room sensor kit is designed to sense the air temperature at a remote location and send this information by digital communication to the thermostat (used on Slim Line and Flat Stat thermostats only). NP THERMOSTAT SLIM LINE THERMOSTAT FLAT STAT THERMOSTAT 6

7 Dimensions 40QA BASE DIMENSIONS NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Standard unit clearances are as follows: 0 in. on top and rear 3in.onleftside 12 in. on right side 36 in.on bottom (When facing unit discharge.) WEIGHT (lb) A B E F G 40QA_ Cooling Only Heat Pump ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm / / / / / / / / / / / / / / /

8 Performance data Fresh air and ducting The ceiling-suspended fan coil units may bring in up to 30% fresh air. The percentage of air allowable is calculated based on the unit high speed cfm. Air quantities above this level may exceed compressor maximum saturated suction temperatures. A power ventilation kit is available to overcome ventilation duct static. See Power Ventilation Kit Available Static Pressure table below. POWER VENTILATION KIT AVAILABLE STATIC PRESSURE FAN CFM AT STATIC PRESSURE (in. wg) DUCT WATTS RPM VOLTAGE HP 0 1/ 8 1/ 4 3/ 8 1/ 2 3/ / 2 DIA. (in.) 1 / / SYSTEM OPERATING CONDITIONS OPERATING LIMITS FAN COIL S TEMP CONDITION Maximum Room Temperature (F) 84 Minimum Room Temperature (F) 64 Maximum Return Air (F) Dry-Bulb 85 Wet-Bulb 72 Minimum Return Air (F) (Heat Pump) 28 Electrical data VOLTAGE VOLTAGE FAN HEATER POWER MINIMUM V-Ph-60 Hz Min Max FLA kw FLA MCA MOCP FLA WIRE SIZE (AWG) 40QAB / QAB / QAB / QAB / QAB / ** QAE / QAE / QAE / QAE / * QAE / ** LEGEND AWG American Wire Gage FLA Full Load Amps HACR Heating, Air Conditioning, and Refrigeration LRA Locked Rotor Amps MCA Minimum Circuit Amps MOCP Maximum Overcurrent Protection Amps (Fuse or HACR) *The 40QAB/QAE018 is a 40QAB/QAE024 unit using a different motor speed fan tap plug. One fan is 1.1 amps, the second fan is 0.5 amps. **Two fans each operating at 1.3 amps. 8

9 Typical wiring schematics 53QAB-330 COOLING SYSTEM WIRING DIAGRAM LEGEND ASM Air Sweep Motor ASR Air Sweep Relay ASW Air Sweep Switch C Contactor CAP Capacitor CLO Compressor Lockout COMP Compressor CR Control Relay CT Current Transformer DR Delay Relay EQUIP GND Equipment Ground FL Fuse Link FPT Freeze Protection Thermostat FR Fan Relay FU Fuse HP Heat Pump HPS High-Pressure Switch HR Heater Relay HTR Heater HTT Heater Temp Thermostat IFM Indoor Fan Motor LPS Low-Pressure Switch OFM Outdoor-Fan Motor OL Overload PDR Pump Delay Relay PL Plug PM Pump Motor PSS Pump Shut-off Switch ST Start Thermistor TB Terminal Block TDR Time Delay Relay TRAN Transformer Terminal (Marked) Terminal (unmarked) Splice Terminal Block Factory Wiring Field Control Wiring Field Power Wiring Printed Circuit Board Accessory or Optional Wiring NOTES: 1. If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent. 2. Wire in accordance with National Electrical Code, NEC) and all local codes. 3. Transformer is thermally protected and will reset automatically. 4. IFMs, OFM and COMP have internal thermal protection. 5. The CLO locks out the compressor to prevent short cycling on compressor overloads and safety devices. Before replacing CLO check these devices. Minimum of one amp turn required to hold contacts closed. 6. H1 terminal and H1 to H2 jumper used only when indoor unit is a heat pump model. 7. When using thermostat with air sweep function: YellowwirefromG3tobeconnectedtoASR1. BlackwiretobedisconnectedfromASR1. Leave black wire tie-wrapped to yellow wire. 9

10 Typical wiring schematics (cont) 38HDL AND 40QAB, 40QAE SYSTEM WIRING DIAGRAM 10

11 LEGEND ASM Air Sweep Motor ASR Air Sweep Relay C Contactor CAP Capacitor CH Crankcase Heater (060 Only) CLO Compressor Lockout COMP Compressor CR Control Relay CT Current Transformer DFB Defrost Board (Outdoor Unit) DFT Defrost Thermostat DR Delay Relay DTS Discharge Temp. Sensor EQUIP. GND Equipment Ground FL Fuse Link FPT Freeze Protection Thermostat FR Fan Relay FU Fuse HP Heat Pump HPS High-Pressure Switch HR Heater Relay HTR Heater HTT Heater Temp Thermostat IFM Indoor Fan Motor LPS Low-Pressure Switch OFM Outdoor-Fan Motor OL Overload PDR Pump Delay Relay PL Plug PM Pump Motor PSS Pump Shut-off Switch RVS Reversing Valve Solenoid SC Start Capacitor SR Start Relay SSDR Safety Switch Delay Relay TB Terminal Block TDR Time Delay Relay TRAN Transformer Terminal (Marked) Terminal (unmarked) Splice Terminal Block Factory Wiring Field Control Wiring Field Power Wiring Printed Circuit Board Accessory or Optional Wiring NOTES: 1. If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent. 2. Wire in accordance with National Electrical Code, NEC) and all local codes. 3. Transformer is thermally protected and will reset automatically. 4. IFMs, OFM and COMP have internal thermal protection. 5. The CLO locks out the compressor to prevent short cycling on compressor overloads and safety devices. Before replacing CLO check these devices. Minimum of one amp turn required to hold contacts closed. 6. H1 terminal and H1 to H2 jumper used only when indoor unit is a heat pump model. 7. When using thermostat with air sweep function: Yellow wire from G3 to be connected to ASR1. Black wire to be disconnected from ASR1. Leave black wire tie-wrapped to yellow wire. 53QAE-330 HEAT PUMP SYSTEM WIRIING DIAGRAM 11

12 Typical piping and wiring TYPICAL INSTALLATION CEILING-SUSPENDED SYSTEMS LEGEND φ Phase NEC National Electrical Code Piping Line Voltage 24 V Thermistor *Standard. Accessory item. **Field supplied. Insulate for heat pump application. NOTES: 1. All piping must follow standard refrigerant piping techniques. 2. All wiring must comply with the applicable local and national codes. 3. Liquid line need not be insulated on cooling unit. 4. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. 5. Insulate condensate drain if run above a conditioned space. 6. AccuRater device is provided. 7. Check piston/charge chart for proper piston size depending on condenser match. 12

13 Controls Sequence of operation Automatic air sweep All under-ceiling units are equipped with an automatic air sweep feature, which automatically directs the airflow louvers up and down to provide optimum room air circulation. If the automatic sweep feature is not desired, temporarily start the automatic sweep using the toggle switch on the unit. When the louvers are in the desired position, turn the automatic sweep off to hold them in that position. Operating sequence Ceiling-suspended fan coil units have a relay board which controls system operation in response to the room thermostat. The user may manually select any one of 3 fan speeds for unit operation. Ceilingsuspended systems may be equipped with an accessory power ventilation kit and/or condensate pump. Duct-free splits thermostat operation Operating mode memory After the system is turned off or after a power failure the system remains in the last operating mode selected. When the system is turned back on, or when power is automatically restored, operation continues in the same operating mode as when the system shut down. Automatic operation (auto) mode If Auto. mode is selected, the system automatically switches over the operating mode from heating to cooling, or from cooling to heating depending on the selected temperature. Auto. mode also controls fan speed if not manually overridden. Fan operation Fan speed can be selected by pressing the fan button (either high, medium, or low speed). The fan is capable of operation when unit mode is set on cooling, heating, or auto. mode. When the fan is operating in medium or high speed and the unit is equipped with the power ventilation kit, the ventilation fan will operate to provide fresh air. Increased demand for cooling (heat pump systems) 1. When the room thermostat senses a demand for cooling, the fan coil relay board is energized and the indoor fan will start in the selected speed (if it is not already operating). 2. The reversing valve is energized at all times when in cooling mode. 3. The internal condensate pump (if so equipped) runs whenever the reversing valve is energized. The internal condensate pump (if so equipped) runs whenever there is a demand for cooling. 4. As long as the condensate float switch and freeze protection thermostat are closed, the cooling relays in the fan coil unit will close. This energizes the compressor and outdoor fan in the outdoor unit. The compressor will continue to operate until the room thermostat is satisfied. 5. When the cooling demand is satisfied, the compressor and outdoor fan will stop. If the system is in Auto. mode, the indoor fan will stop with the compressor. If the unit has the accessory ventilation kit, the ventilation fan will operate whenever the indoor fan is set for medium or high speed. Increased demand for heating (heat pump systems) 1. When the room thermostat senses a demand for heating, the fan coil relay board is energized 2. The indoor fan will start in the selected speed (if it is not already operating). The reversing valve will not be energized.the internal condensate pump (if supplied) and freeze protection thermostat are not operated during heating operation. 3. The control relay closes, and the compressor and outdoor fan are energized through the defrost and the defrost timer runs. 4. Once every 90 minutes (the factory default setting) of the compressor run time, the DFB (defrost board) logic checks the defrost thermostat (DFT). If the DFT is open, the unit continues in heating operation. If the DFT is closed, the DFB switches the unit to defrost mode. The timing on the DFB may be set at either 30, 50 or 90 minutes. Defrost The DFB energizes the RVS (reversing valve solenoid), and the reversing valve switches to the cooling position. The relay on the DFB opens and the outdoor fan stops. The contact on the DFB is also energized, which in turn energizes the defrost relay on the fan coil relay board, turns off the electric heater and stops the indoor fan. The DFB logic checks the 10-minute defrost timer and the DFT. If the DFT opens in less than 10 minutes, the defrost board switches the unit back to normal heating operation. If the DFT remains closed the DFB switches the unit back to heating operation after 10 minutes. When the DFB changes back to heating mode, the RVR (reversing valve relay) is deenergized and the reversing valve switches back to heating operation. Both the outdoor and indoor fans come back on, and if necessary, the electric heater also turns on. System safeties The system is equipped with the following safety devices to protect system components: Indoor coil freeze protection thermostat (cooling cycle only). If a coil temperature of 28 F or lower is sensed, the compressor and outdoor fan will be shut down until the coil temperature exceeds 28 F. The indoor fan will continue to run. Condensate float switch (units equipped with accessory condensate pump, cooling cycle only) If the level of condensate in the drain pan rises too high the condensate float switch will turn off the compressor and outdoor fan until the condensate level returns to normal. The indoor fan will continue to run. Special operation heat mode Outdoor cooling units can be matched with heat pump ceiling-suspended fan coil units to provide supplemental electric heat. All other operation is the same as a cooling only system, except these units have the following heating capability: When the room thermostat initiates a call for heating, the electric heater is turned on. The indoor unit fan will start at the same time if it was not already operating. When the heating requirement is satisfied, the room thermostat will open and the heater will turn off. 13

14 Guide specifications 40QA ceiling-suspended cooling only units Commercial Air-Cooled Condensing Units HVAC Guide Specifications Size Range: 1 1 / 2 to 5 Tons, Cooling Capacity Carrier Model Numbers: 40QAB and 40QAE Part 1 General 1.01 SYSTEM DESCRIPTION Indoor, direct expansion, ceiling-suspended fan coil QUALITY ASSURANCE A. Systems shall be rated and certified in accordance with ARI Standards 210/240. Units shall be listed in the ARI directory as a matched set. B. Systems shall be listed with UL (Underwriters Laboratories) and UL, Canada DELIVERY, STORAGE, and HANDLING Units shall be shipped in one piece and shall be stored and handled per unit manufacturer s recommendations WARRANTY The 40QA unit is covered by a 1-year parts warranty. Part 2 Products 2.01 EQUIPMENT A. General: Indoor, direct-expansion, ceiling-suspended fan coil. Fan coil shall be shipped complete with cooling coil, fan, fan motor, piping connectors, and ceiling mounting brackets. B. Unit Cabinet: 1. Unit cabinet shall be zinc-coated bonderized steel finished with a baked enamel paint. 2. Inlet grilles shall be attractively styled, highimpact polystyrene. 3. Matching mounting brackets shall be provided. C. Fans: 1. Indoor fans shall be 3-speed centrifugal blower type with air intake in the bottom rear of the unit and discharge in the front. 2. Automatic, motor-driven horizontal air sweep shall be provided standard. D. Coils: 1. Indoor coils shall be copper tube with aluminum fins and galvanized steel tube sheets. 2. Fins shall be bonded to the tubes by mechanical expansion. 3. A drip pan under the coil shall have a drain connection for the hose attachment to remove condensate. NOTE: Units use the AccuRater piston refrigerant metering device in the indoor unit for cooling and the AccuRater liquid line service valve for heating. E. Motors: Motors shall be a permanently lubricated ball bearing with inherent overload protection. F. Refrigeration Components (Condenser): Refrigerant circuit components shall include brass external vapor supply line service valve(s), vapor return line service valve(s) with service gage connection port, service gage port connections on compressor suction and discharge lines with Schradertype fittings (located at outdoor unit). G. Filters: Unit shall have filter track with field-supplied cleanable filters. H. Thermostat Controls: 1. Automatic restart after power failure at the same operating conditions as at failure. 2. Thermostat control to enter set points and operating conditions. 3. Cooling mode to provide modulating fan speed based on the difference between temperature setpoint and space temperature. 4. Fan-only operation to provide room air circulation when no cooling is required. 5. Fan speed control shall be user-selectable: high, medium, low, or automatic operation during all operating modes. 6. A time delay shall prevent compressor restart in less than 2 to 4 minutes. 7. Automatic heating-to-cooling changeover to provide automatic heating and cooling operation. Control shall include deadband to prevent rapid mode cycling. NOTE: See selected thermostat instructions for further information. I. Electrical Requirements: 1. Unit shall operate on single-phase, 60 cycle power at 208/230 v as specified on the equipment schedule. 2. Unit electrical power shall be a single point connection. 3. Unit control voltage shall be 24-v. All power and control wiring shall be installed per NEC and all local building codes. 4. Unit shall have low-voltage terminal block connections. 14

15 J. Special Features (Field Installed): 1. Internal Condensate Pump: The condensate pump shall remove condensate from the drain pan when gravity drainage cannot be used. The lift capability of the condensate pump shall be direct vertical 20 inches. Float control shall be in the condensate sump to shut the unit down in case of a pump malfunction. 2. Fresh Air Intake kit: The fresh air intake kit shall include the filter and duct connections to provide for outdoor ventilation air. 3. Power Ventilation Kit: The power ventilation kit shall be used with the accessory fresh air kit when fresh air must be ducted in. The kit will overcome duct static to provide a constant supply of ventilation air. The kit consists of booster fan and adjustable speed control to properly balance the fan to achieve the required airflow rate. 4. Slim Line Thermostat: The Slim Line thermostat shall incorporate 3-speed control, programmability, autochangeover, backlight, locking keypad and a large LCD display. 5. Flat Stat Thermostat: The Flat Stat thermostat shall incorporate 3-speed control, programmability, autochangeover, backlight, locking keypad and a large LCD display that is mounted flush to the wall. (Cooling only and heat/cool systems only.) 6. NP-Thermostat: The NP-thermostat shall include 3-speed control, (Monday through Friday - Saturday - Sunday) programmability, autochangeover, backlight, locking keypad and a large LCD display. (Cooling only and heat/cool systems only.) 15

16 Carrier Corporation Syracuse, New York Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 New Book 2 Pg 16 Catalog No Printed in U.S.A. PC 111 Form 40QA-1PD Tab 3e 2f Tab 2DF Replaces: New

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION...1-9 Step 1 Complete Pre-Installation Checks...1 UNPACK UNIT INSPECT SHIPMENT Step 2 Select Location...1

More information

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Console Console Condenser & Mulit-Zone Satellite HDC, HDL, HDS & QR Condensers High Wall AN/BK Condensers Under Ceiling Cassette Copyright 2001

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES wiring diagrams SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS Cancels: New 542J Sizes 150, 180 12-1/2 and 15 Tons WD 542J.150.1 7/15/96 UNIT 542J 150 180 LABEL DIAGRAM TYPE Component Arrangement Schematic Component

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet

More information

wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX

wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT Cancels: New 569C Sizes 072 to 120 576B Sizes 090-120 575A Size 090 WD 569C.72.4 8/15/02 UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM

More information

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz Wiring Diagrams 38ARZ007-012 38ARS008-012 38ARD012-024 Air-Cooled Condensing Units 50/60 Hz UNIT 38AR DIAGRAM INDEX VOLTAGE-PHASE-HERTZ LABEL DIAGRAM FIGURE NO. 208/230-3-60 38AK540117 1 or 2* 400/460-3-50/60

More information

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons Product Data 50ZP Single-Package Air Conditioners 2 to 5 Tons UNIT 50ZP The 50ZP unit is a packaged air conditioner for manufactured housing, residential, and light commercial applications. The 50ZP unit

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Wiring Diagrams DIAGRAM INDEX

Wiring Diagrams DIAGRAM INDEX 50TFF004-014 Single Package Rooftop Electric Cooling Units Wiring Diagrams DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 50TFF Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes Product Data AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes 3 / 4 to 3 Nominal Tons a42-4013 a42-4014 UNIT SIZES 08-12 UNIT SIZES 18-36 Hydronic ceiling cassette units offer: 6 chilled water cooling models

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES FACTORY- ASSEMBLED PACKAGE is a compact, fully self-contained, electric cooling unit with horizontal supply and return ducts. The PA1Z units are available in a variety of standard cooling sizes with voltage

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons (60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Product Data. Features/Benefits. 19XB Positive Pressure Storage System Product Data 19XB Positive Pressure Storage System 19XB028 Copyright 1992 Carrier Corporation 19XB052 Carrier s Positive Pressure Storage (PPS) System ensures the critical conservation of refrigerants

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE 90.1 certification

More information

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits Product Data 50ZH Single-Packaged Heat Pumps 2 to 5 Tons Single-Package Heat Pump Units with: easy installation design corrosion-proof basepan redesigned aerodynamic fan blade for reduced sound sloped

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions Installation, Start-Up and Service Instructions 38HDF018-036 Duct Free Condensing Units 38HDR018-060 Ducted Condensing Units CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION... 1-10 Step 1 Complete

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Wiring Diagrams Units Produced After April 20, 2009

Wiring Diagrams Units Produced After April 20, 2009 UNIT 38AH 0-034 Wiring Diagrams Units Produced After April 20, 2009 (Includes Variable Air Volume ModuPanel Control) ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/-3-60, 460-3-60 575-3-60 380-3-60-3-50, 380/415-3-50

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Package Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

Duct-Free Systems For cooling and heating solutions, the world turns to Carrier in 2005

Duct-Free Systems For cooling and heating solutions, the world turns to Carrier in 2005 Duct-Free Systems For cooling and heating solutions, the world turns to Carrier in 2005 The Carrier advantage. Carrier is the world s largest air conditioning and heating products manufacturer Carrier

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

PHD3. Product Specifications

PHD3. Product Specifications SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060 40QAC / 38HDR 40QAQ / 38QRR Ceiling---uspended Duct Free plit ystem izes 018 to 060 Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38HDR(QRR)/40QAC(QAQ)

More information

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO. wiring diagrams AIR-COOLED CONDENSING UNIT 566D Sizes 120-240 Cancels: New WD 566D.120.1 11/15/96 UNITS PRODUCED AFTER JANUARY, 1996 INDEX UNIT 566D 120-240 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) SCHEMATIC

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling Product Data 28CB, 28LA Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Copyright 2001 Carrier Corporation 28LA Direct-expansion evaporator coils that easily accommodate upflow

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons Product Data 50SX High Efficiency Single-Packaged Cooling Units 2 to 5 Nominal Tons 50SX High Efficiency, Single-Packaged Cooling Unit for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS 16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling Product Data 28CB, Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Direct-expansion evaporator coils easily accommodate upflow or horizontal light-commercial applications Features/Benefits

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion 38ARZ/ARD Commercial Air-Cooled Split Sizes 007-028 With 40RM007-028 6-25 Nominal Tons - 50Hz Product Data The 38ARZ/ARD condensing units with scroll compressors match Carrier s 40RM indoor-air handlers

More information