1 22/04/16 A1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Copeland Scroll Compressor Micro-channel all aluminum coils have high corrosion resistance Swept-wing fan blade reduces unwanted noise PSC, permanently lubricated motor Removable top grill assembly and louvered condenser guard Complete metal wrapper to protect the condenser coil High pressure switch with auto reset Easy compressor and control access Liquid line filter drier included Composite base pan absorbs sound and is corrosion resistant 16 SEER Models Also Feature: Comfort Alert TM Module; detects system and electrical problems Copeland Scroll Ultra Tech TM Compressor Low pressure switch with auto reset Ton HP Model Part 13 SEER 1 1/2 1/8 FS4BD018KB F 2 1/8 FS4BD024KB F 2 1/2 1/8 FS4BD030KB F 3 1/4 FS4BD036KB F 3 1/2 1/4 FS4BD042KB F 4 1/4 FS4BD048KB F 5 1/4 FS4BD060KB F 16 SEER 2 1/4 FS4BF024KA F 2 1/4 FS4BF024KB F 3 1/4 FS4BF036KA F 3 1/4 FS4BF036KB F 4 1/3 FS4BF048KC F 5 1/3 FS4BF060KC F 13 SEER Dimensions FS4BD 018KB 024KB 030KB 036KB 042KB 048KB 060KB H 24 1/4" 24 1/4" 28 1/4" 28 1/4" 29" 29" 33" W 23 1/4" 23 1/4" 23 1/4" 23 1/4" 31 1/4" 31 1/4" 31 1/4" D 23 1/4" 23 1/4" 23 1/4" 23 1/4" 31 1/4" 31 1/4" 31 1/4" 16 SEER Dimensions FS4BF 024KA 024KB 036KA 036KB 048KC 060KC H 45" 33" 45" 37" 41" 45" W 31 1/4" 22 3/4" 31 1/4" 30 3/4" 30 3/4" 30 3/4" D 31 1/4" 22 3/4" 31 1/4" 30 3/4" 30 3/4" 30 3/4" WARRANTY ON FRIGIDAIRE AIR CONDITIONERS 10 Year Parts: 10 years on all parts when product is registered, 5 years when not registered 10 Year Comfort Quality Pledge: Replacement of entire unit if compressor fails within the first 10 years from installation date when registered, 1 year when not registered (must be matched Frigidaire condenser & coil to qualify) Warranty Registration: Register your system within 60 days of installation Extended Warranty Protection: Ask your Davies Rep for specific details on labor protection plans

2 22/04/16 A1-1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Copeland Scroll Compressor Composite base pan absorbs sound and is corrosion resistant PSC, permanently lubricated motor Removable top grill assembly High pressure switch with auto reset Liquid line filter drier Easy compressor and control access Complete metal wrapper to protect the condenser coil All aluminum Micro-Channel Coils, provides high corrosion resistance Ton HP Model Part 13 SEER 2 1/8 JS4BD024KB J 2 1/2 1/8 JS4BD030KB J 3 1/4 JS4BD036KB J 3 1/2 1/4 JS4BD042KB J 4 1/4 JS4BD048KB J 5 1/4 JS4BD060KB J 13 SEER Dimensions JS_BD 024K 030K 036K 042KB H 27 1/2" 27 1/2" 35 1/2" 27 1/2" W 22 3/4" 22 3/4" 22 3/4" 30 3/4" D 22 3/4" 22 3/4" 22 3/4" 30 3/4" 048KB 060KB 27 1/2" 31 1/2" 30 3/4" 30 3/4" 30 3/4" 30 3/4" WARRANTY ON PHILCO AIR CONDITIONERS 5 Years: Parts Coverage 10 Years: When Registered SEE WARRANTY DOCUMENTS FOR TERMS & CONDITIONS Warranty Registration: Register your system within 60 days of installation

3 03/10/14 A1-2 Air Conditioner Coils Cased Air Conditioner Coils - R-410A Refrigerant - TXV "A" Coil NOTE: Should Sell # Filter Drier With Every TXV Coil See page A13-1 for complete filter drier listing Replacement TXV Assembly for C6 Cased Coils Fits C6 Coil Model Part C6BAX24C-A/B C6BAX30C-A/B/C C6BAX35C-A/B, C6BAX36C-B/ C, C6BAX37C-C C6BAX42C-B/C/D C6BAX48C-C/D C6BAX60C-C/D Ton Overall W x H Depth C6 Series Use with Condenser Model Part FS4BD018KA 1.5 or /4" x 20 3/74" 20 3/4" FS4BD024KA C6BAX24CA FS4BF024KA FS4BD018KA 1.5 or /2" x 20 3/4" 20 3/4" FS4BD024KA C6BAX24CB FS4BF024KA /2" x 26 3/4" 20 3/4" FS4BF024KA C6BHX24CB /4" x 20 3/4" 20 3/4" FS4BD30KA C6BAX30CA /2" x 20 3/4" 20 3/4" FS4BD030KA C6BAX30CB " x 26 3/4" 20 3/4" FS4BD030KA C6BAX30CC /2" x 20 3/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX35CB /2" x 26 3/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX36CB " x 26 3/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX36CC x 30 1/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX37CC /2" x 26 3/4" 20 3/4" FS4BF036KA C6BHX36CB " x 26 3/4" 20 3/4" FS4BF036KA C6BHX36CC /2" x 26 3/4" 20 3/4" FS4BD042KA C6BAX42CB " x 26 3/4" 20 3/4" FS4BD042KA C6BAX42CC /2" x 30 1/4" 20 3/4" FS4BD042KA C6BAX42CD " x 30 1/4" 20 3/4" FS4BD048KA FS4BF048KA C6BAX48CC A /2" x 30 1/4" 20 3/4" FS4BD048KA FS4BF048KA C6BAX48CD " x 30 1/4" 20 3/4" FS4BD060KA FS4BF060KA C6BAX60CC /2" x 30 1/4" 20 3/4" FS4BD060KA FS4BF060KA C6BAX60CD See Page A3 for Complete Coil Information

4 03/10/14 A2 Air Conditioner Coils Uncased Air Conditioner Coils - R-410A Refrigerant - TXV "A" Coil C5 Coil NOTE: Should Sell # Filter Drier With Every TXV Coil See page A13-1 for complete filter drier listing Replacement TXV Assembly for C6 Uncased Coils Fits C6 Coil Model Part C6BAX24U-A/B C6BAX30U-A/B/C C6BAX35U-A/B, C6BAX36U-B/ C, C6BAX37U-C C6BAX42U-B/C/D C6BAX48U-C/D C6BAX60U-C/D Ton Overall W x H Depth Use With Condenser Model Part C5 Series 5 21" x 28 3/4" 19 1/2" 060KA C5BAX60UC D C6 Series 1.5 or /4" x 19" 19 1/2" FS4BD018KA FS4BD024KA FS4BF024KA C6BAX24UA or 2 16" x 19" 19 1/2" FS4BD018KA FS4BD024KA C6BAX24UB FS4BF024KA /4" x 19" 19 1/2" FS4BD030KA C6BAX30UA /2" x 23 3/4" 19 1/2" FS4BD030KA C6BAX30UC " x 24 3/4" 19 1/2" /2" x 23 3/4" 19 1/2" FS4BD036KA FS4BF036KA FS4BD036KA FS4BF036KA C6BAX36UB C6BAX36UC /2" x 28 3/4" 19 1/2" FS4BD036KA FS4BF036KA C6BAX37UC " x 24 3/4" 19 1/2" FS4BD042KA C6BAX42UB /2" x 23 3/4" 19 1/2" FS4BD042KA C6BAX42UC " x 24" 19 1/2" FS4BD042KA C6BAX42UD /2" x 28 3/4" 19 1/2" 4 23" x 28 1/4" 19 1/2" /2" x 28 3/4" 19 1/2" 5 23" x 28 1/4" 19 1/2" C6 Coil FS4BD048KA FS4BF048KA FS4BD048KA FS4BF048KA FS4BD060KA FS4BF060KA FS4BD060KA FS4BF060KA C6BAX48UC A C6BAX48UD C6BAX60UC C6BAX60UD See Page A3 for Complete Coil Information

5 25/02/11 A3 Air Conditioner Coils Coil Data Charts C6 TXV Cased Coil C5 TXV Uncased Coil C6 TXV Uncased Coil

6 04/05/12 A3-1 Air Conditioner Coils Vertical Cased Air Conditioner Coils - R-410A Refrigerant - "A" Coil Ton Overall W x H Depth Model Part C6 "A" Coils /2" x 30 1/4" 20 3/4" C6BAX60CC /2" x 30 1/4" 20 3/4" C6BAX60CD C7 Vertical "A" Coils /2" x 20 3/4" 20 3/4" C7BAM01824C-A /2" x 20 3/4" 20 3/4" C7BAM03036C-A /2" x 20 3/4" 20 3/4" C7BAM01824C-B /2" x 20 3/4" 20 3/4" C7BAM03036C-B /2" x 26 3/4" 20 3/4" C7BAM03642C-B " x 26 3/4" 20 3/4" C7BAM030C-C " x 26 3/4" 20 3/4" C7BAM03648C-C /2" x 30 1/4" 20 3/4" C7BAM042C-D /2" x 30 1/4" 20 3/4" C7BAM048C-C /2" x 30 1/4" 20 3/4" C7BAM048C-D NOTE: Should sell # Filter Drier With Every Coil Frigidaire & Philco condensers come with Filter Drier See page A13-1 for complete filter drier listing See Page A3-4 for Complete Coil Information

7 04/05/12 A3-2 Air Conditioner Coils Horizontal Cased Air Conditioner Coils - R-410A Refrigerant - "A" Coil Ton Overall W x H Depth Model Part C7 Horizontal "A" Coils /2" x 20 3/4" 20 3/4" C7BHM01824C-A /2" x 20 3/4" 20 3/4" C7BHM03036C-A /2" x 20 3/4" 20 3/4" C7BHM01824C-B /2" x 20 3/4" 20 3/4" C7BHM03036C-B /2" x 26 3/4" 20 3/4" C7BHM03642C-B " x 26 3/4" 20 3/4" C7BHM030C-C " x 26 3/4" 20 3/4" C7BHM03648C-C " x 30 1/4" 20 3/4" C7BHM04860C-C /2" x 30 1/4" 20 3/4" C7BHM042C-D " x 30 1/4" 20 3/4" C7BHM04860C-D NOTE: Should sell # Filter Drier With Every Coil Frigidaire & Philco condensers come with Filter Drier See page A13-1 for complete filter drier listing See Page A3-4 for Complete Coil Information

8 24/05/13 A3-3 Air Conditioner Coils Uncased Air Conditioner Coils - R-410A Refrigerant - "A" Coil Ton Overall W x H Depth Model Part C6 Series /2" x 28 3/4" 19 1/2" C6BAX60UD C7 Series /4" x 18 1/2" 19 1/2" C7BAM01824U-A /4" x 18 1/2" 19 1/2" C7BAM03036U-A " x 18" 19 1/2" C7BAM01824U-B " x 18" 19 1/2" C7BAM03036U-B " x 25" 19 1/2" C7BAM03642U-B /2" x 18" 19 1/2" C7BAM030U-C /2" x 24 1/2" 19 1/2" C7BAM03648U-C " x 23 3/4" 19 1/2" C7BAM042U-D /2" x 28 1/2" 19 1/2" C7BAM048U-C " x 27 3/4" 19 1/2" C7BAM048U-D C7 Series NOTE: Should sell # Filter Drier With Every Coil Frigidaire & Philco condensers come with Filter Drier See page A13-1 for complete filter drier listing See Next Page for Complete Coil Information

9 04/05/12 A3-4 Air Conditioner Coils Coil Data Charts

10 04/05/12 A3-5 Air Conditioner Coils C6 Cased & Uncased "A" Coil TXV Kits C7 Uncased "A" Coil TXV Kits Tons Refrigerant Type Part R A 2.5 R A 3 R A 3.5 R A 4 R A 5 R A R-410A A 2.5 R-410A A 3 R-410A A 3.5 R-410A A 4 R-410A A 5 R-410A A

11 01/11/13 Air Conditioner Coil Wrappers & Close Off Kit A4 C5 Coil Wrappers For Uncased Coils Fits Cabinet Size Overall Width Overall Height Brand Part A 14 1/4" 20" Frigidaire B 19 3/4" 26" Frigidaire C6 & C7 Coil Wrappers For Uncased Coils Cabinet Identifier Overall Width (W) Overall Height (H) Liquid Line Height (HL) Suction Line Height (HS) Opening Width (OW) Brand Part C6 & C7 Coil Wrappers A 14 1/4" 20 3/4" 17 1/2" 15 1/2" 12 7/8" Frigidaire A 14 1/4" 26 3/4" 23 1/2" 21 1/2" 12 7/8" Frigidaire B 17 1/2" 20 3/4" 17 1/2" 15 1/2" 16 1/8" Frigidaire B 17 1/2" 26 3/4" 23 1/2" 21 1/2" 16 1/8" Frigidaire C 21" 26 3/4" 23 1/2" 21 1/2" 19 5/8" Frigidaire C 21" 30 1/4" 27" 25" 19 5/8" Frigidaire D 24 1/2" 30 1/4" 27" 25" 23 1/8" Frigidaire D 34" Frigidaire Close Off Kit For Cased Coils Description Kit for adapting a cased coil to a smaller width furnace. This could be either a C5 series coil with a narrower G7 furnace or a C6 series coil with a G6 or L1 furnace. Part

12 17/01/14 A5 Air Conditioners Covers Air Conditioner Covers - Customized Logo Custom printed covers are a cost effective marketing tool that promotes your company to the homeowner and neighbors - a great source of new leads, referrals, callbacks and name recognition Logo printed in any one color in one location (side or top) Logo size: 8" x 14" Minimum order of 30 Custom printed covers are a cost effective marketing tool! Call Davies for more information! Air Conditioner Covers Attractive AC cover with a glove like fit Keeps dirt and debris out of condensing unit Heavy duty vinyl resists slipping or tearing and is also specially treated to protect against mold, mildew and UV rays Helps prevent corrosion of electrical contacts 1/2" gap at bottom provides cross-ventilation to provide air flow and prevent condensation Velcro strap easily secures cover around suction and discharge lines Size: L"xW"xH" Part 22 3/4 x 22 3/4 x 34 1/4 0084A 22 3/4 x 22 3/4 x 26 1/2 0084B 30 3/4 x 30 3/4 x 26 1/2 0085B 30 3/4 x 30 3/4 x 30 1/2 0085C 23 1/4 x 23 1/4 x 24 1/4 0655C 23 1/4 x 23 1/4 x 28 1/4 0655D 23 1/4 x 23 1/4 x 36 1/4 0655B 31 1/4 x 31 1/4 x D 31 1/4 x 31 1/4 x A 31 1/4 x 31 1/4 x C Note: See AC Accessories Quick Pick Guide for model to cover chart

13 25/06/10 A6 Air Conditioner Accessories Brackets Heavy duty engineered steel brackets used for mounting A/C condensers and heat pumps on vertical walls Includes mounting holes and are finished in a durable grey powder coat Description Brand Part 30" Steel Bracket (pair) Mars " Steel Bracket (pair) Mars " Steel Bracket (pair) Mars Connectors - Liquid Tight, Non-Metallic Conduit - Liquid Tight, Non-Metallic PVC flexible connectors Indoor or outdoor use UV rated material for long outdoor life Reusable design Resists salt water, weak acids, gasoline, alcohol, oil, grease and most common solvents Size Description Brand Part 1/2" Straight Connector Mars /4" Straight Connector Mars /2" 90 o Connector Mars /4" 90 o Connector Mars Rigid coils combined with flexible PVC construction provide superior wire protection Use on a large variety of AC, refrigeration and HVAC equipment Resilient to abuse, pulling or crushing Use with PVC liquid tight connectors Temperature range -18C to 75C (0F to 167F) Size Length Brand Part 1/2" 100' Mars /4" 100' Mars 84119

14 03/10/14 A7 Air Conditioner Accessories Compressors Single and three phase replacement compressors 1 year limited warranty BTU Capacity Volts Phase Fits Model Brand Part Single Phase - Fits R22 10 SEER 16, /230 1 FS3BA018KA Copeland , /230 1 FS3BA024KA Copeland , /230 1 FS3BA030KA Copeland , /230 1 FS3BA036KA Copeland , /230 1 FS3BA042KA Copeland , /230 1 FS3BA048KA Copeland , / Copeland , /230 1 FS3BA060KA Copeland Single Phase - Fits R22 13 SEER 24, /230 1 FS5BD024KA Copeland , /230 1 FS5BD030KA Copeland , /230 1 FS5BD048KA Copeland , /230 1 FS5BD060KA Copeland Three Phase 32, / Copeland , / Copeland , / Copeland , / Copeland , / Tecumseh Air Compressor Sound Blanket Simple cost-effective solution to compressor noise Cheaper than replacing or moving equipment Minimum 5 db or 40%+ reduction of compressor noise Fits well over 200 different models of compressor Works with either hermetic or scroll compressors Convenient easy to install universal-fit design Convenient hook and loop straps to simplify installation Description Brand Part Compressor Sound Blanket Brinmar SBUHD

15 25/06/10 Disconnect A8 Air Conditioner Accessories Line, load and ground terminals aligned for ease of wiring Side door opens 180 degrees for maximum access Full dead front Convertible door for left or right swing cul Listed Description Brand Part 60A Non-fusible disconnect switch Diversitech DDS-60U Equipment Pads - Ultralite Solid base gives five times more foundation surface than a plastic ribbed pad Lightweight Stays flat and stable, will not sink into the ground Retains strength and color in direct sunlight Vibration absorbing, it will not crack or chip Non slip surface Little or no ground preparation Limited lifetime warranty Size Weight lbs. Brand Part 26" x 28" x 2" 16 Diversitech UC " x 32" x 2" 22 Diversitech UC " x 36" x 2" 27 Diversitech UC Evaporator - Anti-Ice Controls 18AEIC1 A AEIC1 Evaporator Coil Low Temperature Limit When attached to the suction line of the evaporator coil and wired in series with the Y connection to the compressor, its normally closed contact will shut down the refrigeration compressor when it senses the evaporator coil freezing up. 3/4" cup. A Heat Pump Control Designed to be wired in series with the cycling control. The capillary senses the evaporator temperature and shuts the compressor off. When the temperature reaches 60 o F the contacts close and restart the unit. Capillary Length: 30" Temperature Setting Brand Part Opens Closes 2.8C (37F) 15C (59F) Alltemp 18AEIC1-1C (30F) 16C (60F) Robertshaw A

16 25/06/10 Fan Centres A9 Air Conditioner Accessories Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or air conditioning systems Transformer powers low voltage control systems and provides overload protection Mounts on standard 4" x 4" junction box Low voltage terminal board provides convenient connections for thermostat and heating, cooling equipment wiring R8285A A05A-101 Motor 120VAC Input Voltage Switching Action Full Load Locked Rotor Brand Part 40 VA, 60Hz SPDT 12.0A / 6.0A 35A / 72A Honeywell R8285A VAC, 60Hz DPST 8.0A / 14.0A 48.0A / 84.0A White Rodgers 8A05A-101 Filter Driers - Liquid Line - Solder Type Standard used with most refrigerant/lubricant combinations High moisture removal capacity Very low pressure drop Filtration down to 10 microns Copper sweat connectors Powder coated finish is 1000 hours salt spray rated 500 psig safe working pressure Nominal Tons Inlet / Outlet Connection Overall Length Diameter Brand Part 1/3-2 3/8" ODF 4.5" 2" Frigidaire (053S) 1-4 3/8" ODF 5.37" 2.5" Frigidaire (083S) 2-5 3/8" ODF 6.06" 2.5" Frigidaire (163S) 2-5 1/2" ODF 6.06" 2.5" Frigidaire (164S)

17 25/06/10 Fittings- Nylon A10 Air Conditioner Accessories Nylon fittings for AC coil installations Description Size Part A coil adapter, 2/pack 1/2" Barb x 3/4" MPT A coil adapter, 2/pack 5/8" Barb x 3/4" MPT Drain hose elbow for ac coils, 2/pack 1/2" Barb x 3/4" MPT Drain hose elbow for ac coils, 2/pack 3/4" Barb x 3/4" MPT Drain hose elbow for ac coils, 2/pack 5/8" Barb x 3/4" MPT Hard Start Kits Combination Start Relay, Start Capacitor & Motor Overload (32781 / 32741) -Designed to replace those components on a 115 volt single phase refrigeration compressor installed on a capillary tube system. -Factory wired (wiring diagram on the product label) -Leads have push-on terminals for easy installation -Compact & universal Combination Relay and Safety Timer (DST-6) -Offers a larger capacitor for severely hard-to-start compressors -500% torque multiplier -Can be used on all PSC single phase compressors -Automatically disconnects in 0.5 seconds if the compressor fails to start HP Volts Brand Part 1/12 to 1/5 HP 115 VAC Mars /4 to 1/3 HP 115 VAC Mars /2 to 10 HP 120 to 288 VAC Diversitech DST-6 DST-6 Low Ambient Control Low Ambient Control Temperature Setting Opens Closes Brand Part 7C (45F) 13C (55F) Alltemp

18 12/05/17 Linesets A10-1 Air Conditioner Accessories For split system air conditioning applications Quick and easy field installation Length 25' 50' 25' 50' Liquid Line (Non-Insulated) Suction Line (Insulated) Insulation Thickness Part 3/8" 3/4" 3/8" LS /8" 3/4" 3/8" LS /8" 7/8" 3/8" LS /8" 7/8" 3/8" LS Sight Glass Moisture Indicators Provides a quick visual diagnosis of refrigerant and moisture levels in the liquid line of a refrigeration or air conditioning system Features copper fittings to permit solder installation without disassembly Simple color comparison provides quick diagnosis Maximum working pressure: 500psig (35 bar, 3447 kpa) Maximum temperature: 60C (140F) Size 3/8" ODF 1/2" ODF Description Brand Part Solder connection, solid brass body Frigidaire Solder connection, painted solid brass body Frigidaire

19 31/12/10 A10-2 Air Conditioner Accessories Copper Tubing Refrigeration Type "R" or "ACR" Certified to ASTM B 280 Soft, seamless and annealed for flexibility Description Coil Length Part 1/8" OD ACR Copper Tubing 50' CTR2X50 3/16" OD ACR Copper Tubing 50' CTR3X50 1/4" OD ACR Copper Tubing 50' CTR4X50 5/16" OD ACR Copper Tubing 50' CTR5X50 3/8" OD ACR Copper Tubing 50' CTR6X50 1/2" OD ACR Copper Tubing 50' CTR8X50 Sold By The 50' Coil 5/8" OD ACR Copper Tubing 50' CTR10X50 3/4" OD ACR Copper Tubing 50' CTR12X50 7/8" OD ACR Copper Tubing 50' CTR14X50 1 1/8" OD ACR Copper Tubing 50' CTR118X50 Tubing Insulation Flexible thermal insulation Will not absorb moisture over long periods of use Weather resistant High resistance to common corrosive chemicals Black, marked in blue ink Inside Diameter Wall Thickness Length Part 5/8" 3/8" 6' /4" 3/8" 6' /8" 3/8" 6' Whips - Liquid Tight, Non-Metallic Flexible conduit 10 AWG type THHN / THWN / MTW wire Installation Whips Include: Non-metallic liquid tight conduit and fittings (one straight, one 90 o ) and two reducing washers Size Length Exposed Wire On Each End Part 1/2" 4' 11" /2" 6' 11" /2" 6' 24"

20 17/01/14 A10-3 Air Conditioner Accessories Davies stocks a wide selection of equipment and components for any air conditioning installation. Call Davies Experts On Controls. CPVC Tubing & Fittings Condensate Pumps Vinyl Tubing Copper Tubing Tubing Insulation Copper Fittings Fan Relays Definite Purpose Contactors Thermostats Thermostat Wire Fast Stat

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PSH4BF Series M1010 Product Line R-410A Ultra High Efficiency Heat Pumps 15+ SEER 2-5 Ton 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE Maytag

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The JS5BD Series of air conditioners offers exceptional performance. The unit,

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise

More information

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES 1-year warranty on parts and labor. 5-year compressor warranty. If Registered a 10 year limited parts warranty applies. Designed for maximum

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Table of Contents AIR CONDITIONING EQUIPMENT

Table of Contents AIR CONDITIONING EQUIPMENT Table of Contents Page Split System Residential Units...........................502-508, 539-543 Air Conditioning, Heat Pumps......................502-508, 539-543 Blower Units, Coils................................528-533,

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump RTG Ultron Split System Heat Pump Specification Sheet Up to 16 SEER Cooling : 35,000-56,500 BTUH Heating : 33,600-56,400 BTUH LIMITED WARRANTY Lifetime Replacement of Entire Unit if Compresssor Fails 10-Year

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS 16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant

More information

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Specially Designed. SilentComfort Fan Guard. Visit us at   For the latest technical information, ENGINEERING DATA Heavy Gauge Steel Cabinet With Powder Paint Finish Lennox System Operation Monitor (LSOM) Specially Designed SilentComfort Fan Guard CONDITIONERS HSXA19 DAVE LENNOX SIGNATURE COLLECTION

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System 1.5-5 Ton The DT5BD Series of heat pumps offers exceptional performance. The heat pump, when combined with our

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com

HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com SWEPT FAN BLADE TECHNOLOGY Napoleon air conditioners are made with modern fan blade technology. The unique swept shape of the blades make

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A6018-61 PUB. NO. 12-1350-03 February 2015 Features and Benefits DURATION compressor Efficiency up to 17.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION HEAT PUMP OUTDOOR UNITS lps13dc DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 210637 June 2014 Supersedes June 2012 1.5 to 5 Tons MODEL NUMBER IDENTIFICATION L P S 13 DC - 036-230 - 2 Lennox Minor

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data Three Phase 2TTA3048-060A3 4 5 Tons PUB. NO. 22-1770-03 Features and Benefits All aluminum Spine Fin coil Durable base, fast complete drain, weather proof

More information

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers) WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-03-EN Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Ruud Achiever Series Air Conditioners

Ruud Achiever Series Air Conditioners 16.0 Air Conditioners Ruud Achiever Series Air Conditioners Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XB16 4TTB6 1 1 / 2-5 Tons PUB. NO. 22-1888-01 Features and Benefits Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners QUICK-SESS cabinet, service

More information

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models FORM NO. A22-188 REV. 3 Supersedes Form No. A22-188 Rev. 2 CONDENSING UNITS JEZ 16 Two- Models Efficiencies up to 17.10 Nominal Sizes 2 to 5 Tons [7.03 kw] to [17.06 kw] Four Models Cooling Capacities

More information

RSG16**S1M. Split System Air Conditioner 16 SEER

RSG16**S1M. Split System Air Conditioner 16 SEER RSG16**S1M Split System Air Conditioner 16 SEER COMPRESSOR High-efficiency 2 stage Copeland UltraTechTM scroll compressor R410a refrigerant Grommet-mounted compressor for quiet operation Internally protected

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model DT4BD Series M120 Product Line High Efficiency R-410A Heat Pump 13 SEER 1.5-5 Ton 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet Air Conditioning and Heating SPECIFICATION sheet MHH 13 SEER High Efficiency R410a Split System Heat Pump Standard features: R410a system High efficiency compressor Compact design for easy installation

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com

HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com THINK DIFFERENT. THINK NAPOLEON. Napoleon s central air conditioners boast quiet operation features and a natural taupe color to effortlessly

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

Ruud Ultra Series Variable Speed Heat Pumps

Ruud Ultra Series Variable Speed Heat Pumps Seasonal Energy Efficiency Ratio - SEER THIS MODEL 10.0 USES LESS ENERGY 17.00 17.0 Heat Pumps Ruud Ultra Series Variable Speed Heat Pumps Efficiencies up to 20 SEER/14.5 EER/11 HSPF Nominal Sizes 2, 3,

More information

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS EL6XC ELITE Series R-40A Bulletin No. 20833 July 208 Supersedes March 208 SEER up to 7.90.5 to 5 Tons Cooling Capacity - 7,800 to 60,000 Btuh MODEL NUMBER IDENTIFICATION

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

SCE170 SERVICE PARTS

SCE170 SERVICE PARTS This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

HIGH EFFICIENCY AIR CONDITIONERS 13 SEER. Engineered and Made in Canada. napoleonheatingandcooling.com

HIGH EFFICIENCY AIR CONDITIONERS 13 SEER. Engineered and Made in Canada. napoleonheatingandcooling.com 13 SEER HIGH EFFICIENCY AIR CONDITIONERS Engineered and Made in Canada napoleonheatingandcooling.com SWEPT FAN BLADE TECHNOLOGY Napoleon air conditioners are made with modern fan blade technology. The

More information

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-07 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 13 SEER R-410A High Efficiency Split System These units have been designed and tested for capacity & efficiency in accordance with

More information

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

AMERICAN STANDARD 14 MODELS 4A7B E

AMERICAN STANDARD 14 MODELS 4A7B E SPLIT SYSTEM COOLING 1 1 / 2 5 ton AMERICAN STANDARD 14 MODELS 4A7B4018-60E PUB. NO. 12-1290-02 June 2009 Features and Benefits DURaTION compressor Efficiency up to 16.0 SEER All aluminum Spine Fin coil

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A4018-24C/30-060B 2009 American Standard Heating & Air Conditioning PUB.. 12-1173-04 April 2009 Features and Benefits Duration compressor Efficiency

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

14 AC x

14 AC x PRODUCT SPECIFICATIONS AIR CONDITIONERS 14ACX MERIT Series R-410A Bulletin 210565 April 2013 Supersedes February 2013 SEER up to 16.70 1.5 to 5 Tons Cooling Capacity - 16,900 to 59,500 Btuh MODEL NUMBER

More information

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated,

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE M1200 16 SEER Comfort Systems Maytag M1200 Extra-High Efficiency 16 SEER Two-Stage Air Conditioners & Heat Pumps Maytag two-stage technology allows

More information

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S E N G I N E E R I N G D A T A H E A T P U M P O U T D O O R U N I T S 14HPX MERIT SERIES R 410A Bulletin No. 210492 April 2008 Supersedes April 2007 SEER up to 15.0 1.5 to 5 Tons Capacity 19,100 to 59,000

More information

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL (MH4) MULTI-ZONE HEAT PUMP AIR CONDITIONING SYSTEM Rev. 1.4 [3/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT DESIGNATION:

More information

AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE AND WORRY-FREE PERFORMANCE M1200 COMFORT SYSTEMS UP TO 16 SEER AIR CONDITIONERS OR HEAT PUMPS AIR HANDLERS COILS EXTRA-HIGH EFFICIENCY UP TO 16 SEER TWO-STAGE systems include two main components. M aytag

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A7 2014 American Standard Heating & Air Conditioning PUB. NO. 12-1348-02 August 2014 Features and Benefits DURATION 2-stage scroll compressor Efficiency up

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 3 5 Tons PUB. NO. 22-1791-16-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S A I R C O N D I T I O N E R S XC16 ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology E N G I N E E R I N G D A T A Bulletin No. 210465 May 2006 SEER up to 16.50 2 to 5 Tons Cooling Capacity

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-05 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-06 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

Specifications and Performance S2H

Specifications and Performance S2H DUCTLESS SPLIT SYSTEM Dual-ZONE Heat Pump CONDENSING UNIT P/N# 240006613, Rev. A [06/08] Specifications and Performance Heat Pump Nominal Capacities: 9,000 and 12,000 Btuh DESCRIPTION EMI offers the finest

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-14-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL (MC2) MULTI-ZONE STRAIGHT COOL AIR CONDITIONING SYSTEMS Rev. 1.4 [4/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XB14 4TTB4 1 1 /2-5 Tons (018E - 061E) PUB. NO. 22-1833-08 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY CONDENSING UNITS RAWD- 6 1 2 & 7 1 2 TON RAWE - 6 1 2 & 7 1 2 TON! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!! WARNING

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

Self-Contained Reverse Cycle Air Conditioners

Self-Contained Reverse Cycle Air Conditioners Self-Contained Reverse Cycle Air Conditioners Models MA 07-10-12-16-24 General Description Marvair's water source self-contained reverse cycle air conditioners are designed for use in either fresh or salt

More information

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE AND WORRY-FREE PERFORMANCE M1200 Comfort Systems 13-16 SEER Air Conditioners or Heat Pumps Air Handlers Coils Extra-High Efficiency up to 16 SEER Two-Stage systems include two main M aytag components.

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information