Make value of the waste energy from your cooling units and heat water for free
|
|
- Eustacia Lewis
- 6 years ago
- Views:
Transcription
1 Make value of the waste energy from your cooling units and heat water for free INTERNATIONAL PATENT PENDING
2 Stop wasting! The energy consumption of water heaters represents an increasing proportion of the operating costs. Cooling units produce large amounts of heat; this heat is lost, rejected in the ambient air by the fans and often causes nuisances. Boostherm heat recovery module reclaims this waste energy to heat up water for free. Boostherm limits the energy bill to refrigeration with 100% free hot water production while reducing cooling units nuisances. Boostherm recovers 100% of the heat Amount of heat recovered with Traditional heat recovery systems only recover desuperheating phase from hot gases, which represents less than 20% of the recoverable energy. In that case, the heat exchange temperature is not mastered: it is high in summer and low in winter. P HP Condensation Classic desuperheater Boostherm heat recovery system recovers all the condensation heat generated by the cooling unit. This enables to heat up water very quickly at a minimum temperature of 55 C even in difficult conditions. LP Expansion Evaporation Compression H Dual Condense (DCT) patented technology: 1. «Water condenser» mode: The heat recovery system condenses all the refrigerant gas using the cold water from the water tank. It recovers all the heat rejected by the cooling unit. The electronic board adjusts the pump speed to heat up the water at 55 C in one pass whatever the ambient temperature. 2. Desuperheating» mode: When all the water has been preheated, the electronic regulation switches the fans on. The heat recovery system continues heating up the water (gas desuperheating); water can reach a temperature of 65 / 70 C in summer. The system runs within the operating envelope of the compressors (pressure and temperature); Water condensation improves the compressor efficiency in summer and avoids high pressure cut-off. The HP safety pressure sensor restarts ventilation in case of water circuit dysfunction: priority is given to refrigeration. The cheapest energy is the one that is not consumed
3 Many benefits: Free hot water production: Energy bill reduction. Recycles and valorizes wasted thermal energy: Free hot water production in large quantities at high temperature. Reduces cooling units nuisances (fan noise, heat rejected). Energy savings: Environmental impact reduction. For many applications: 1 kw cooling capacity = 400 litres hot water heated from 12 to 55 C daily = kwh saved per year * The system is intended to all small, medium-sized and larger companies who have on one hand a need for cooling (ex: cold rooms, refrigerated display case, air conditioning) and on the other hand a need for heating (hot water production, premises heating). Hotels Restaurants Large kitchens Supermarkets Slaughterhouses Examples: Bakeries Catering industries Butchery Fish store Food processing Bakery: 450 litres hot water used per day x 300 days One negative refrigeration cabinet equipped cooling unit 1.5 HP (650 W) Annual savings: kwh Restaurant 200 meals/day: 1200 litres hot water used per day x 300 days One negative cold room 3 HP (1150W) and one positive cold room 1HP (1400W) equipped Annual savings: kwh Slaughterhouse 500 poultry /day: 3500 litres hot water used per day x 240 days One positive central cooling plant 34 kw equipped Annual savings: kwh Meat processing plant: litres hot water used per day x 240 days one semi-hermetic cooling unit 40 kw equipped Annual savings: kwh * 400 of hot water heated based on -10 C evaporating temperature and 15 hours a day cooling unit operation kwh per year based on 6 working days per week x 50 weeks. Make a complete techno-economic study in a few clicks on
4 Features Heat recovery module: Stainless steel protection box. Insulated double wall high pressure heat exchanger for optimal security. Pre-assembled module with electrical connection for quick installation. Electronic regulation board with auto-tuning (no settings). Multi-refrigerant system (R134a, R404a, R407a, R407c, R407f, R410a, R449a...) Variable speed circulation pump. Components compatible with drinking water. Frost protection. LED warning scale formation. Refrigerant leak detection. > Priority to cooling: HP safety pressure sensor, NC fan relay for a trouble-free operation in case of anomaly on the heat recovery system. Module capacity (condenser) 5 kw 10 kw 20 kw 45 kw 70 kw 100 kw Height (mm) Width (mm) Depth (mm) Min. buffer tank volume (l) Min. combined tank volume (l) Boostherm combined water tanks: More than simple hot water buffer tanks: carefully designed to optimize heat recovery and equipped with a water diffusing stick to obtain two different temperature levels and avoid the influence of the electrical resistance in the part dedicated to heat recovery. Also equipped with a separate cold water inlet to avoid cold water by-pass during heat recovery phase. Single water tank for preheated and hot water, with anti-legionella conception. Epoxy-coated 3mm steel tank 7 years warranty*. PVC cover with 50mm insulation foam (insulation heat transfer coefficient K = W/ m2. C). Total drain orifice and quick drain valve to easily remove deposits. Magnesium protection anode. Connection kit including safety valve, air vent, 2 thermometers, quick drain valve and fittings. Optional electrical resistance. Boostherm water tanks can also be used as buffer tanks. * See warranty conditions in the instructions manual Volume 300 l 500 l 750 l 1000 l 1500 l 2000 l 3000 l 5000 l Height (mm) * Tank diameter (mm) Diameter with insulation (mm) Weight (kg) * Height without upper elbow or air vent: total height = height mm.
5 Typical hydraulic diagrams (more examples: download the selection guidelines on Assembly with a Boostherm water tank used as combined tank (Preheated water & top up). Hot Water Hot water area Optional: Preheated water Preheated water area Heat recovery circulation loop Cold water inlet Assembly with 1 Boostherm tank used as combined tank with 2 heat recovery modules. Hot water Non return valve: Cold water inlet Main circulation loop Secondary heat recovery circulation loop Assembly with low temperature air heaters Low temperature air heater OPTIONAL: Additional Low temperature heater. Controlled pump Buffer tank Expansion tank Return max 25 C Circuit filling
6 Sizing (more information: see selection guidelines or the online simulator on Simplified sizing method (R404A or R22 ; other refrigerants : see selection guidelines) Determine the heat load at the condenser based on the maximum evaporating temperature on normal operation (Condensing temperature =40 C on negative applications, 45 C on positive applications, sub-cooling=0k and Superheat=10K). Select the module of corresponding nominal power. Recoverable thermal capacity in W To=-35 C To=-25 C To=-10 C To =0 C To=10 C Thermal capacity in W Heat recovery performances Water volumes heated from 12 to 55 C: (based on average evaporating temperature) Running time in hours Savings generated Estimated savings depending on hot water needs: Hot water needs (L/day) Savings (kwh/year) Basis: 6 working days per week x 50 weeks. Ecolactis CD ZA du Champ Pourceau Messigny et Vantoux - France + 33 (0) contact@boostherm.com Boostherm is a registered trademark of SARL Ecolactis Cooling capacity in W Complete method: Qm = P x k x 0.02 Qm: Water volume heated from 12 to 55 C in L/h P: Thermal capacity in W k: Correction factor Thermal capacity in W Correction factor k P < < P < < P < < P < Complete method: Sav = V x D x 0.05 Sav: Estimated annual savings (kwh/year) V: Hot water needs (L/day) D: Number of working days Dealer / Installer: Ref. : B EN Ecolactis se réserve le droit de procéder à toutes modifications sans préavis. Images non contractuelles.
Heat recovery systems - Free hot water by total recovery of the heat rejected by the cooling units
Heat recovery systems - Free hot water by total recovery of the heat rejected by the cooling units Summary : - Why Boostherm? For whom? - Heat recovery module functioning - Highlights & benefits - Boostherm
More informationv SELECTION GUIDELINES
v 2.2-01-2016 SELECTION GUIDELINES 1. SYSTEM PRESENTATION... 3 2. INSTALLATION SIZING... 6 3. SPECIFICATIONS... 11 4. DHW DIAGRAMS... 12 5. HEATING DIAGRAMS... 15 6. COOLING DIAGRAMS... 17 7. PRESSURE
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationCOMPANY Presentation Focus on SANDEN Environmental Solutions
COMPANY Presentation Focus on SANDEN Environmental Solutions Liste de diffusion Top management General Manager Manager Manager de Tout le proximité monde SANDEN Group Worldwild specialist in heating and
More informationAQUAHEAT ADVANCE SPLIT
AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationSUBCRITICAL & TRANSCRITICAL SYSTEMS
R744 CO2 SYSTEMS SUBCRITICAL & TRANSCRITICAL SYSTEMS ORIGINAL MANUFACTURED EQUIPMENT R744 CO2 Systems BA-508-3 AUS In 2004 BITZER Australia introduced the Enviro-Cold CO 2 System to the Australian Refrigeration
More informationHYDROCIAT LW R407C. Water cooled chillers USE RANGE
Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationAQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING
Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou
Condensers ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM A. Hadawey, Y. T. Ge, S. A. Tassou 4 7 8 5 3 2 6 1 Produced by: The Centre for Energy and Built Environment
More informationSweden s leading air source heat pump
- Since 1939 ExoAir / ExoAir Polaris GreenEnergy Sweden s leading air source heat pump BEST IN TEST The Swedish Energy Council recently scored the Euronom air source heat pump as the leading product of
More informationAQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING
Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More information3 rd Generation of VRV. The professional solution for your professional project
3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,
More informationABSTRACT. 2 CanmetENERGY
ABSTRACT In spring 2004, Loblaw Companies Limited (Loblaw) decided to innovate at their new Loblaws supermarket in Repentigny (QC) by adopting refrigeration technologies and operating practices pioneered
More informationRefrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.
Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure. MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661..
More informationAPPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps
APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual Suggestions for the hydraulic integration of chillers and heat pumps Table of Contents From practical experience, for your practical needs...
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationSHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C
SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationHeat Pump Water Heater Commercial Leaflet 2012
Heat Pump Water Heater Commercial Leaflet 2012 1 Table of contents............... 2 Bosch Group Innovation as a principal Established in 1886 in Stuttgart, Germany, Robert Bosch Corporation has been characterised
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationEQUIPMENT SNOW DOMES / SKI DOMES
EQUIPMENT SNOW DOMES / SKI DOMES Refrigeration needs of snow domes and ski domes can vary significantly depending on several factors: The size of the dome The weather conditions outside Occupancy and thermal
More informationDaikin Blueprint: Delivering Hot Water with a Chiller
Daikin Blueprint: Delivering Hot Water with a Chiller Analyzing the design of heat recovery on air-cooled chillers and the effect it has on building energy consumption By Paul Crisman Daikin Chiller Applications
More informationRefrigeration Training System
3401-20 Refrigeration Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List of Manuals 3 Table
More informationEXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump
HEAT PUMP WATER HEATER EXPLORER 7% energy savings * Wide temperature range of use (- to + C) ACI hybrid anti-corrosion protection Smart energy consumption control Remote piloting with Cozytouch technology
More informationnext generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)
next generation R 1 cycling refrigerated compressed air dryers flow capacity: 20-2000 scfm (32-3210 Nm 3 /hr) cycling refrigerated compressed air dryers R 1 flow capacity: 20-2000 scfm (32-3210 Nm 3 /hr)
More informationnemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING
171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw 172 VERSIONS
More informationSOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!
SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Comfort Module 5-2 kw Choose the easy heating solution! Comfort Module: heating with Carrier system innovation Proper control of heat pumps is key to
More informationSHERPA. Air-water split heat pump. COP > 4 ACS a 60 C
Air-water split heat pump. COP > 4 ACS a 60 C Energy class: 35 55 RENEWALE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity
More informationOwner Municipality Built in 1978 Rebuilt in 2001 Rink and bleachers. Surface area (footprint) 4,140 m 2 (44,700 ft 2 )
Project profile Refrigeration Technological Innovation RAPB REFRIGERATION ACTION PROGRAM For BUILDINGS Colisée des Bois-Francs Victoriaville (Québec) MAJOR RETROFIT Summary Potential for substantial heat
More informationNATURAL REFRIGERANT SYSTEMS
R744 CO 2 SYSTEMS NATURAL REFRIGERANT SYSTEMS SINGLE & MULTIPLE COMPRESSOR SYSTEMS SUB-CRITICAL / TRANS-CRITICAL ORIGINAL MANUFACTURED EQUIPMENT R744 CO2 SYSTEMS In 2004 BITZER Australia introduced the
More informationR717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D
R717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D TECHNICAL UNIVERSITY OF CIVIL ENGINEERING BUCHAREST The Faculty of Building Services Thermodynamics Heat and Mass Transfer
More informationECOCIAT. Domestic hot water heat recovery unit. Use. Range
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION
More informationLeadership, Innovation, Advanced Technology Synergise Here!
Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified
More informationAir to Water Heat Pump Utilising Natural Refrigerant C02
Air to Water Heat Pump Utilising Natural Refrigerant C02 1 Contents 1. Product Outline 2. General Features Q-ton Dimensions 3. Product Efficiency Comparisons 4. Commercial Applications 5. Beneficial Applications
More informationDEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA
DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA Daniel Giguère, Technology Expert Georgi Pajani, Engineer Sophie Hosatte, Section Head, Buildings CETC-Varennes, Natural
More informationNRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER
NRP MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. NRP MULTIPURPOSE
More informationPACKAGED REFRIGERATION CONDENSING UNITS
PACKAGED REFRIGERATION CONDENSING UNITS 1.7kW 64.2kW Nomenclature UNDERSTANDING THE ACPAC MODELS The Acpac part numbers are based around a nomenclature system, which means there is thought behind the names,
More informationPACKAGED REFRIGERATION CONDENSING UNITS
PACKAGED REFRIGERATION CONDENSING UNITS 1.7kW 64.2kW Nomenclature UNDERSTANDING THE ACPAC MODELS The Acpac part numbers are based around a nomenclature system, which means there is thought behind the names,
More informationREFRIGERATION HEAT RECOVERY
REFRIGERATION HEAT RECOVERY REFRIGERATION HEAT RECOVERY EVER DREAMT OF SAVING MONEY BY USING ENERGY TWICE? y How does it work? x Ridel-Energy s equipment produces hot water from energy you have already
More informationSplit inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45
Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The
More informationPROCESS AND CLIMATE COOLING
PROCESS AND CLIMATE COOLING Cold and warm water system Creating a good indoor climate. cold AND warm WAter SYstem Cold & warm To heat AND cool down AT the SAme time! If we are suffering from heat, our
More informationProcess glycol chillers
Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic
More informationEnvironmentally friendly refrigeration systems for industrial use
compindustri Environmentally friendly refrigeration systems for industrial use CO ² refrigeration systems of the future GENERAL INFORMATION compindustri More than 10 years of development of refrigeration
More informationLargo & Allegro. Air Compressors. Largo & Allegro 31-90
Largo & Allegro Air Compressors Largo & Allegro 31-90 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 85 years of industrial experience. It is our ambition to offer compressed
More information500 EX Fusion Compressor Series
500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications
More informationSeries 4. Rotary rack oven. For pastry chefs and bakers, Series 4 rotary rack ovens concentrate a range of technology to ensure real benefits:
Series 4 Rotary rack oven For pastry chefs and bakers, Series 4 rotary rack ovens concentrate a range of technology to ensure real benefits: - Extremely compact - Excellent performance - Ecological - Guaranteeing
More informationF-H Refrigerated Dryers
F-H Refrigerated Dryers Engineered to Save Refrigeration Dryers F-H Series refrigeration dryers are the final result of intensive research and development program. The result is the most efficient direct
More information50A KP 70A KP 90A KP 120A KP 150A KP 210A
DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw
More informationSmall Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.
Small Commercial Business Energy Audits Recognizing and addressing the special requirements of the small business market segment. Class 7 Class 7: Refrigeration Fundamentals The Vapor-compression cycle
More informationF Series - Refrigeration dryers
F Series - Refrigeration dryers Quality compressed Air Flows from 0,38 to 110 m 3 /min QUALITY, DRY COMPRESSED AIR: THE EFFECTS: Considerably reduced production costs. Circuit protected against corrosion.
More informationUS Supermarket Modeling Activities
New Supermarket Modules for EnergyPlus Van D. Baxter Building Technologies Integration Program Oak Ridge National Laboratory IEA Annex 31 Workshop Zurich, Switzerland May 19, 2008 Managed by UT-Battelle
More informationApplication of two hybrid control methods of expansion valves and vapor injected compression to heat pumps
AM-4249223-1 - Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps Christian K. Bach, Graduate Student, Eckhard A. Groll, Reilly Professor, James
More informationA study of Transient Performance of A Cascade Heat Pump System
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 79 (2015 ) 131 136 2015 International Conference on Alternative Energy in Developing Countries and Emerging Economies A study of
More informationc Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L
Refrigeration Cycles Dr. Md. Zahurul Haq Professor Department of Mechanical Engineering Bangladesh University of Engineering & Technology (BUET) Dhaka-1000, Bangladesh zahurul@me.buet.ac.bd http://teacher.buet.ac.bd/zahurul/
More informationMeasurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.
Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation. Bengt Perers 1, Elsa Andersen 2, Simon Furbo 2, Ziqian Chen 2 and Agisilaos
More informationRollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V
Rollair Air Compressors Rollair 40 to 125 and Rollair 40 V to 125 V Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has over 145 years of industrial experience.
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.
product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for
More informationChiller units and air-water heat pumps RANGE OPERATING LIMITS
Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning
More informationINSTALLATION, COMMISSIONING AND OPERATING MANUAL
INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical
More informationT270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354
Refrigerators, Air-conditioners & Heat Pumps Refrigeration Cycles Dr. Md. Zahurul Haq Professor Department of Mechanical Engineering Bangladesh University of Engineering & Technology (BUET) Dhaka-1000,
More informationFTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR
FTQ SERIES DUCTED HEAT PUMP SYSTEMS INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR FTQ SERIES DUCTED HEAT PUMP SYSTEMS LEADING TECHNICAL PERFORMANCE
More informationand sanitary hot water Catalogue 2009
heating, COOLING and sanitary hot water Catalogue 2009 LG Electronics Magyar Kft. H-1097 Budapest, Könyves K. krt. 3/a. (+36-1) 455-6060 www.lg.hu www.lgeaircon.com http://lgacademy.csx.hu For continual
More informationINTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012
HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.
More informationA WET-VAPOUR INJECTION AND VARIABLE SPEED SCROLL COMPRESSOR AIR TO WATER HEAT PUMP MODEL AND ITS FIELD TEST VALIDATION
Paper O.2.2.4-1 - A WET-VAPOUR INJECTION AND VARIABLE SPEED SCROLL COMPRESSOR AIR TO WATER HEAT PUMP MODEL AND ITS FIELD TEST VALIDATION Laurent Dardenne*, Enrico Fraccari*, Alessandro Maggioni**, Luca
More informationTube-in-tube heat exchanger Type HE
Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration plant. The purpose is to
More informationExploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump
Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump ACEEE Hot Water Forum 2017 Session 1B February 27 Ben Larson ben@ecotope.com Problem Statement(s) HFC refrigerants
More informationHVS, Hydro Variable System
water systems HVS, Hydro Variable System Air cooled chiller / heat YDC_522H (-C) / YDC_972H (-C) / YOC_762H (-C) / YOC_1522H (-C) A complete range from 15 kw up to 72 kw R407C Remote Central Controller
More informationWater chillers water/water type SIGMA Technical information manual
Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity
More informationBWL air heat pumps BWS brine heat pumps
BWL air heat pumps BWS brine heat pumps Wolf - Heat pumps Benefits offered by Wolf heat pumps From each 1 kwh power, heat pumps generate between 3 and 5 kwh heat Free environmental energy from the ground
More informationACMVTECH HIGH EFFICIENCY UNITARY AHU
HIGH EFFICIENY UNITARY AHU 50 / 60 Hz R-134A, R407c R-407F, R-410A ACMVTECH HIGH EFFICIENCY UNITARY AHU WATER COOLED CONDENSERS VARIABLE and CONSTANT SPEED VSD FANS ; VSD COMPRESSORS ACMCVTECH UNITARY
More information> > > Heat pump systems. Water Chillers. Dehumidifiers
> > > Heat pump systems Water Chillers Dehumidifiers Company Profile What is a heat pump? A heat pump is a device that moves heat from one location (called the source ) to another location (called the
More informationSeries 4. Rotating rack oven Fuel-oil / Gas
Series 4 Rotating rack oven Fuel-oil / Gas Designed for confectioners as well as bakers, the hi-tech features of the Series 4 rotating rack ovens guarantee real benefits: - Extremely compact - Offers an
More informationENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER
Poster P.4.2 - - ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER Jan Sedlar, University Centre for Energy Efficient Buildings and Faculty of Mechanical Engineering, Czech Technical University in Prague, Czech
More informationUpdate Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South
3/5/2018 1 Update Dedicated Heat Recovery Chiller Technology Don Frye Gulf South Good design is an intentional act Begin with the end in mind Basic Bldg Tenants IAQ (low VOC & CO 2 ) Controlled Temp &
More informationT H I N K I N S I D E T H E B o x
T H I N K I N S I D E T H E B o x HyperCoreTM microchannel coil technology The name behind the brands you trust. 2175 West Park Place Blvd. Stone Mountain, GA 30087 www.heatcraftrpd.com P 800.537.7775
More informationINSTALLATION AND USER MANUAL
INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal use and maintenance, please read carefully
More informationREFRIGERATED AIR DRYERS SCFM. CRPC Energy Saving Series
REFRIGERATED AIR DRYERS 75 550 SCFM CRPC Energy Saving Series CHAMPION CRPC SERIES Sustainable Energy Saving Solutions Champion is a place where innovation is constant and the real-world needs of our customers
More informationPPL Electric Utilities Energy Efficiency and Conservation Program
Installation of High-Efficiency High Efficiency Evaporator Fans Evaporator Fans That have Highfor Walk-ins Efficiency Permanent Split $50/fan motor Capacitor (PSC) Motor or ECM High Efficiency Compressors
More informationTechnical description. Atec.
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationGeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.
Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept
More informationTHE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium
THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS Jan Boone MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium Tel. 32-2-757-9075, Fax. 32-2-757-9023, e-mail : jan.boone@mayekawa.eu
More information3400-3A Refrigeration System Demonstrator
3400-3A Refrigeration System Demonstrator LabVolt Series Datasheet Festo Didactic en 240 V - 50 Hz 04/2018 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List of Manuals
More informationMicrochannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More informationAir to water Heat Pump System
Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a
More informationA-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.
A-Class A-Rated Homes with Dimplex heat pumps Building Regulations and Part L Compliance made easy with Dimplex. The name you can trust. dimplex.ie AClass A4 Page Brochure-August 2016.indd 1 A-Class Heat
More informationGo Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over
Danfoss Solutions for Cold Rooms Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationnemo a hp rcgroupairconditioning R410A
NEMO A HP: Motoevaporating heat pumps for indoor installation, equipped with scroll compressor and plate heat exchanger Cooling Capacity: 5,5 25,0 Heating Capacity: 6,4 29,3 nemo a hp PLATE rcgroupairconditioning
More informationyour comfort. our world. Altherma Flex Type Renewable heat pump system for every environment
your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More information