Installation and Servicing Instructions

Size: px
Start display at page:

Download "Installation and Servicing Instructions"

Transcription

1 Installation and Servicing Instructions Zenex GasSaver GS-1 Passive Flue Gas Heat Recovery Device (PFGHRD) Recognised by the Government s Standard Assessment Procedure (SAP) IMPORTANT: Read these instructions BEFORE installing the boiler Zenex Technologies Ltd Unit 2, Broadley Park Roborough Plymouth PL6 7EZ Tel: These instructions have been carefully prepared in accordance with the current specification. Zenex Technologies reserves the right to alter the specification at any time. Zenex Technologies Ltd. GasSaver Installation Manual ZXGEN 4.1 Page 1 of 7

2 CONTENTS 1. Introduction Important Information Installation Site Package Contents Installation 4 6. Commissioning Routine Inspection Warranty Information INTRODUCTION The Zenex GasSaver is a revolutionary system designed to increase the energy efficiency of condensing boilers. Classified as a Passive Flue Gas Heat recovery Device (PFGHRD), the GasSaver is recognised under the Government s SAP Appendix Q program for the energy efficiency of dwellings. The GasSaver is fitted to the flue adaptor on top of the boiler (supported by its own mounting bracket). Utilising unique thermal store technology, the GasSaver collects and stores wasted energy from the flue system and re-uses that energy to pre-heat the cold mains water supply to the boiler (or unvented storage cylinder). With no complicated mechanical parts and no electronic devices, the GasSaver is maintenance free and easy to install. How it works 2 IMPORTANT INFORMATION It is essential that you read this section carefully before attempting to handle, install or use the GasSaver. The GasSaver must only be mounted above and used with the boiler specified on the side plate of the unit. Both the GasSaver and the boiler must be installed in accordance with the manufacturer s installation instructions. Failure to do so will negate the warranty supplied with this unit. Zenex Technologies Ltd. GasSaver Installation Manual ZXGEN 4.1 Page 2 of 7

3 It is the law that all gas appliances are installed by a competent person i.e. a CORGI registered fitter in accordance to the following recommendations: Current Gas Safety (Installation and Use) Regulations All current Building Regulations issued by the department for the Environment i.e. Approved Document L1 Building Standards (Scotland)(Consolidation) Regulations issued by the Scottish Development Department UK Water Regulations/Bylaws (Scotland) Health & Safety Document No. 635 The installation should also be in accordance with the following British Standards Codes of Practice: BS 5440:1:2000 Flues BS 5449:1990 Forced Circulation Hot Water Systems BS 5546:2000 Installation Of Hot Water Supplies For Domestic Use BS 6700:1997 Design, Installation, Testing & Maintenance Of Supplying Water BS 6798:2000 Installation Of Gas Fired Hot Water Boilers BS 6891:1998 Gas Installation BS 7593:1992 Code Of Practice For Treatment Of Water In Heating Systems BS 7671:2001 Requirements For Electrical Installation, IEE Wiring Regulations. Failure to install this unit or the boiler correctly could lead to prosecution. It is in your own interest and that of safety to ensure that you comply with the law. Manufacturer s instructions must NOT be taken in anyway as over-riding statutory obligations. 3 INSTALLATION SITE The GasSaver is mounted above the top of the boiler, using a special wall fixing bracket, and is connected directly to the boiler flue outlet. The boiler flue kit is then connected to the flue spigot on top of the GasSaver. Before commencing installation, it is important to ensure that there is adequate clearance above the boiler to accommodate both the GasSaver and the relevant flue kit. The incoming mains water pressure should be between 0.2 and 5 bar to ensure efficient operation. If the incoming pressure is above 5 bar a pressure reducing valve must be fitted prior to the GasSaver pipework The GasSaver flue resistance for 30kW boiler equates to 1.5m of total length of 60/100 flue manufactured length or 1.0m of 80/125 flue. Accordingly, the manufacturer s maximum recommended flue length must be reduced by the relevant distance. Care and consideration should be given to the correct installation and sizing of the boiler condensate drain. We recommend that a tundish or air break should be fitted between the condensate waste pipe from the boiler and drain trap. In areas of hard water (150mg/litre calcium/magnesium), we recommend that water treatment is used to reduce the build up of scale deposits within the secondary heat exchanger. Technical Data Maximum Working Pressure: Condensate Store: Max design flow rate: Water Inlet: Water Outlet: Flue / Air Connections: 5 BAR 5.5 Litres Up to 20 lpm 15mm 15mm To suit boiler Flue Resistance Testing in accordance with EN1859 equates to an overall reduction in manufacturer s maximum flue length specification of: 1.5m length for 60/100 flue 1.0m length for 80/125 flue Zenex Technologies Ltd. GasSaver Installation Manual ZXGEN 4.1 Page 3 of 7

4 4 PACKAGE CONTENTS GasSaver Mounting Bracket (may differ from that shown) GasSaver Top Fixings (Type A or B depending on boiler model) Installation Instructions (This document) Blending Valve (set to 30º) SAP Label (for affixing to boiler) Flue Clamp (If required for boiler fixing) Expansion Vessel (Included with some boiler models) GasSaver A GasSaver Top Fixings (Type A or B) B Mounting Bracket SAP Label Mounting Dimensions Installation Instructions Blending Valve Expansion Vessel (If required) Flue Clamp (If required) 5 INSTALLATION 5.1 Mounting The GasSaver The GasSaver is mounted above the top of the boiler, using a special wall fixing bracket, and is connected directly to the boiler flue outlet. The boiler flue kit is then connected to the flue spigot on top of the GasSaver. Before commencing installation, it is important to ensure that there is adequate clearance above the boiler to accommodate both the GasSaver and the relevant flue kit. Refer to the mounting dimensions drawing enclosed with the GasSaver and mark the position on the wall for the GasSaver mounting bracket, top fixings and flue outlet. Drill and plug the necessary fixing holes and cut the flue hole. Mount the boiler on the wall as described in the boiler installation instructions (do not fit the flue or make the water connections). Note: Temporarily cover the boiler flue spigot to prevent anything from falling into it. If the boiler system requires priming with cold water via the flue spigot, this should be done before fitting the GasSaver. Zenex Technologies Ltd. GasSaver Installation Manual ZXGEN 4.1 Page 4 of 7

5 Attach the GasSaver fixing bracket to the wall using three suitable fixing screws. If the GasSaver is supplied with the Toggle Bolt type fixings (Type B), secure these in position using 4 fixing screws. If the GasSaver is supplied with fixed screw fittings (Type A), these will be fixed later with the GasSaver in position. Remove the temporary cover from the boiler flue adaptor. If a flue clamp is supplied with the GasGaver, check the mounting dimensions drawing and if instructed place the flue clamp loosely over the boiler flue turret. Carefully lift the GasSaver into position over the boiler flue turret and lower the unit into place, keeping the unit level to ensure the GasSaver bottom flue spigot enters the boiler turret squarely. Take care not to dislodge or damage the flue seal in the boiler turret. Locate the GasSaver on its mounting bracket. Take care to keep the unit level and avoid transferring weight to the boiler. Locate and fasten the top fixings as shown on the mounting dimensions drawing. To level the GasSaver, adjust the back nut on the top fixings (Type B) or add / remove spacer washers located behind the GasSaver fixing points (Type A) If a flue clamp is fitted, tighten the clamp to seal the joint. 5.2 Connect The Pipework Outlet Connect the mains cold supply to the pipe marked Inlet using a compression fitting. Connect the pipe marked Outlet to the hot connection of the blending valve (supplied). Note: Only use connection fittings approved for use with stainless steel pipework. Inlet Connect another mains cold supply pipe to the cold connection of the blending valve. Finally, connect a pipe from the mixed connection of the blending valve to the cold water inlet connection of the boiler. GasSaver Typical Combi Installation LEGEND BV E MCW DHW Blending valve Expansion vessel (if required) Mains Cold Water Domestic Hot Water Note: Blending valve set to 30ºC (Minimum setting on adjusting knob) WRAS certification requires an approved single check valve or some other no less effective backflow prevention device to be fitted at the point of connection between the supply and the device. Copyright Zenex Technologies Ltd Zenex designs are protected under Patent No Other patents pending. Zenex Technologies Ltd. GasSaver Installation Manual ZXGEN 4.1 Page 5 of 7

6 5.3 Setting The Blending Valve The blending valve should always be set to limit the temperature of the water entering the boiler to a maximum of 30ºC. This is achieved by turning the adjusting knob fully clockwise to the minimum setting. Note: Do not set the blending valve to setting other than the minimum; otherwise the system may not function correctly. 5.4 Prime The GasSaver The GasSaver relies on a store of water/condensate to deliver maximum benefit, and must be primed prior to first use. When the installation of the pipework is completed, fill the GasSaver by carefully pouring 6 litres of clean, cold water into the top central flue spigot of the GasSaver. Care should be taken to ensure that no water is allowed to spill or enter the outer air duct of the GasSaver 5.5 Fit The Flue When priming is complete, attach the boiler flue kit to the top spigot of the GasSaver as described in the boiler installation instructions. Note: The GasSaver is equivalent to a 1.5m length of 60/100 flue. 6 COMMISSIONING Commission the boiler as described in the boiler installation instructions. Check all pipework connections to the GasSaver for leaks. Finally, attach the self adhesive label supplied with the GasSaver to the boiler so that it is easily visible for inspection. Typically, the label should be located on the inside of the boiler control panel cover so that it can be easily seen with the cover open. 7 ROUTINE INSPECTION It is recommended that the GasSaver should be subjected to a general condition inspection at each boiler maintenance interval. Due to the simplicity of the design, no maintenance is required. The unit contains no mechanical, electrical or serviceable parts. Zenex Technologies Ltd. GasSaver Installation Manual ZXGEN 4.1 Page 6 of 7

7 8 WARRANTY INFORMATION IMPORTANT NOTE: The GasSaver is a self-contained unit designed for use specifically with SEBDUK A and B rated condensing domestic and commercial gas powered boilers to improve their efficiency. You should carefully read this warranty, Zenex Technologies Limited s installation and servicing instructions and any other user guidelines provided for the GasSaver. If not properly handled, installed and used the GasSaver may be damaged, damage property and/or result in serious injury or even death. 1. Statutory Rights Where the purchaser of the GasSaver (the Purchaser ) is a consumer, this warranty does not affect the Purchaser s statutory rights relating to sale of consumer products and product liability. 2. Warranty 2.1. Subject to the exclusions to this warranty set out in section 4 below, Zenex Technologies Limited warrants to the Purchaser that for a period of two years from the date of purchase (the Warranty Period ) the GasSaver when: installed by a competent person (i.e. a CORGI registered installer); used for normal consumer purposes; and used and properly maintained in accordance with Zenex Technologies Limited s installation and servicing instructions, will be free from significant defects in design, materials and workmanship This warranty will be invalidated if the Purchaser does not install or use the GasSaver in accordance with clauses 2.1.1, and above In the event that the GasSaver does not conform with its warranty in section 2.1 above, Zenex Technologies shall, without charge, at its sole discretion: repair the relevant GasSaver ; replace the relevant GasSaver ; or refund the Purchaser the full price paid by the Purchaser for the relevant GasSaver This warranty applies to new GasSavers only. This warranty is only enforceable by the first Purchaser of the relevant GasSaver and is non-transferable. 3. Warranty Period 3.1. The Warranty Period is not capable of extension, except that in the event that Zenex Technologies Limited repairs or replaces the GasSaver or parts thereof under section 2.2 above. In this case the repaired or replaced GasSaver (or parts) shall be warranted under the terms of this warranty either: for the remainder of the Warranty Period; or for a period of twelve months from the date of repair or replacement, whichever is the longer. 4. Exclusions to this Warranty 4.1. This warranty does not cover defects or damage to or failure of the relevant GasSaver caused by any of the following: normal wear and tear to the relevant GasSaver ; abuse of the GasSaver by the Purchaser, including but not limited to dropping, rough handling, impact, exposure to environmental conditions which are likely to corrode, damage or otherwise impede the normal functioning of the GasSaver or using the GasSaver for any use for which it is not intended; installation of the relevant GasSaver with a faulty or defective boiler or the use of any other faulty or defective equipment; failure by the Purchaser to install and/or service the relevant GasSaver correctly or in accordance with Zenex Technologies Limited s installation and servicing instructions, including installation of a GasSaver onto a boiler type for which it is not expressly designed; service or repair of the GasSaver by any person or organisation not expressly authorised for that purpose by Zenex Technologies Limited; alteration of or tampering with the relevant GasSaver by the Purchaser, including but not limited to removing or destroying identification tags/serial numbers, opening, dismantling, adding parts to or otherwise modifying the GasSaver. 5. Entire Warranty and Limitation 5.1. Subject to clauses 5.2 and 5.3 below, this express warranty is the entire warranty provided by Zenex Technologies Limited to the Purchaser and is the Purchaser s only remedy against Zenex Technologies Limited for defects or damage to or failure of the GasSaver and supersedes any other oral, written or contractual warranty given by Zenex Technologies Limited to the Purchaser All or any implied warranties including implied warranties of satisfactory quality and fitness for purpose are expressly excluded from this warranty Nothing in this warranty shall limit Zenex Technologies Limited s liability for death or personal injury or for fraudulent misrepresentation by Zenex Technologies Limited Zenex Technologies Limited shall not be liable whether in tort or contract for indirect, consequential or economic losses, including but not limited to loss of business, loss of profit, damage to equipment or expenses and damages or costs arising out of being unable to use the GasSaver Subject to clause 5.3 above, Zenex Technologies Limited s liability shall be limited to the purchase price of the GasSaver product which causes the alleged damage. 6. Contact 6.1. In order to obtain service pursuant to this warranty, the Purchaser should in the first instance telephone Zenex Technologies Limited on and ask for warranty service or contact Zenex Technologies Limited through its website at The Purchaser will be given full instructions as to how to obtain service When requesting warranty service for a GasSaver in accordance with clause 6.1 above, the Purchaser must provide Zenex Technologies Limited with a receipt or other acceptable proof of purchase relating to the relevant GasSaver, the name and contact details of the authorised installer who installed the relevant GasSaver, a description in writing of the defect and their full name and contact telephone number Zenex Technologies Ltd. GasSaver Installation Manual ZXGEN 4.1 Page 7 of 7

Installation and Servicing Instructions. Alpha GasSaver GS-1

Installation and Servicing Instructions. Alpha GasSaver GS-1 Installation and Servicing Instructions Alpha GS-1 Passive Flue Gas Heat Recovery Device (PFGHRD) for use with an Alpha CD Condensing IMPORTANT: Read these instructions BEFORE installing the boiler For

More information

Installation and Servicing Instructions. Alpha GasSaver GS-2

Installation and Servicing Instructions. Alpha GasSaver GS-2 Installation and Servicing Instructions Alpha GS- Passive Flue Gas Heat Recovery Device (PFGHRD) for use with an Alpha Condensing Combination s IMPORTANT: Read these instructions BEFORE installing the

More information

Installation and Servicing Instructions. Alpha FlowSmart

Installation and Servicing Instructions. Alpha FlowSmart Installation and Servicing Instructions Alpha FlowSmart Hot Water System incorporating an Alpha InTec 30/40GS Condensing Combination Boiler with Integrated Flue Gas Heat Recovery Device and wall mounted

More information

Alpha FlowSmart 25 and 50

Alpha FlowSmart 25 and 50 Installation and Servicing Instructions Alpha FlowSmart 25 and 50 Hot Water System incorporating a Flue Gas Heat Recovery Device, Primary Store and an Alpha CD Condensing Combination Boiler For Technical

More information

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008 Varipoint cover qxd:varipoint cover qxd 22/8/08 11:14 Page 1 Installation, Maintenance and User Instructions ZIP Varipoint III Models VP303, VP503 VP803, VP953 direct unvented water heaters Issued August

More information

Alpha CombiMax 350 and 600

Alpha CombiMax 350 and 600 Installation and Servicing Instructions Alpha CombiMax 350 and 600 Unvented Hot Water Store for use with the Alpha 240/280 Range of Gas Fired Combination Boilers For Technical help or for Service call...

More information

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet. Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy

More information

Installation Instructions

Installation Instructions Installation Instructions The energy you need Accessories/PFGHRD 60/100 Passive Flue Gas Heat Recovery Device Explanation of Symbols a DANGER: Risk of injuries. The PFGHRD is an integral part of the flue

More information

Powerflow Unvented water heater

Powerflow Unvented water heater Product Instruction Manual Powerflow Unvented water heater 30, 50 and 90 litres v15.6/5 Thank you for purchasing a Powerflow series unvented electric water heater. The Powerflow is suitable for hand washing

More information

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented INSTALLATION MANUAL RD SERIES Digital Electric Water Heater Wall-hung Unvented WELCOME Dear Customer, Thank you for choosing the RD Series electric water heater, with an exclusive electronic temperature

More information

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual POWERFLOW Series Unvented Electric Storage Water Heaters Installation & Operating Instructions Manual These Instructions must be left with the user after installation. Version 3.0 June 2009 Hyco POWERFLOW

More information

FlowSmart. The high efficiency, high performance space saving heating system.

FlowSmart. The high efficiency, high performance space saving heating system. FlowSmart. The high efficiency, high performance space saving heating system. 2 FlowSmart For homes with above average hot water demands, look no further than FlowSmart. FlowSmart at last enables even

More information

Industrial Vacuums, Inc

Industrial Vacuums, Inc Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances

More information

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120. MariGlo LED 45 / 60 / 90 / 120 Inspiring Excellence in Fish Keeping! Instruction version: 01/10/2013 Important Safeguards To guard against injury, basic safety precautions should be observed, including

More information

Sound Cover [ , , , ]

Sound Cover [ , , , ] Sound Cover [77001603, 77001604, 77001605, 77001606] Intended Use: To provide lower sound (dba) levels for Midmark PowerAir Compressors. Requirements / Restrictions: After cover is mounted to compressor,

More information

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers Installation instructions Passive flue gas heat recovery device Greenstar Xtra For use with Greenstar CDi Compact, Si Compact and i combi boilers 6 70 830 0 (04/) UK, IE 000004366-00 Table of contents

More information

Installation & Operation Manual

Installation & Operation Manual Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats

More information

INSTRUCTION MANUAL HS-229G

INSTRUCTION MANUAL HS-229G INSTRUCTION MANUAL HS-229G 510977 STEP 1 - Where to Install the Thermostatic Steam Trap Determine where to install the thermostatic steam trap based on the following information. a. The trap should be

More information

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500 Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section

More information

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9 Contents Product Description 2 Approvals 2 Warranty 2 Warnings 2 Technical Specification 3 Installation 4 Location 4 Plumbing Connection 4 Electrical connection 5 Commissioning 6 Operation 6 Routine Preventative

More information

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

Baxi Maxflow Combi WM

Baxi Maxflow Combi WM Baxi Maxflow Combi WM Gas Fired Wall Mounted Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier. User

More information

INSTALLATION AND SERVICING INSTRUCTIONS TO BE LEFT WITH THE USER

INSTALLATION AND SERVICING INSTRUCTIONS TO BE LEFT WITH THE USER ENERGYCATCHER INSTALLATION AND SERVICING INSTRUCTIONS TO BE LEFT WITH THE USER This is an energy saving product SAP RECOGNISED CERT ACCREDITATION Technical and illustrative data are not binding and can

More information

Baxi Maxflow Combi FS

Baxi Maxflow Combi FS Baxi Maxflow Combi FS Gas Fired Floor Standing Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice Vote for your Installer of the year at www.worcester-bosch.co.uk 9/14, 14/19 & 19/24CBi Worcester supports the Benchmark code of practice G. C. NUMBERS APPLIANCE NATURAL GAS LPG 9/14CBi 41 311 50 41 311

More information

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V Cylinder Manual Incorporating: User Instructions Installation Instructions Guarantee Registration Open Vented Cylinders Stainless Steel Water Heaters Products covered by this manual: Twin Coil TW180V TW10V

More information

Field Top Mounted Condensing Unit

Field Top Mounted Condensing Unit Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the

More information

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5 Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5 Solar Mounting Solutions UNI-SA/21.5 March 2009 www.ironridge.com 2009 IronRidge, Inc. All Rights Reserved Version 2.0 2 Universal

More information

STEAM WALLPAPER STRIPPER MODEL HTW5

STEAM WALLPAPER STRIPPER MODEL HTW5 STEAM WALLPAPER STRIPPER MODEL HTW5 From Serial Number 75154 (110 Volt North America only) OWNERS MANUAL & OPERATING INSTRUCTIONS 2016/11 Hiretech Part # 007717 WARNING For safe operation of this machine,

More information

MaxLite LED MICRO-T PANEL

MaxLite LED MICRO-T PANEL ` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all

More information

Patent Pending invent for New Construction

Patent Pending invent for New Construction Patent Pending invent for New Construction Users Manual 3.0 2 Introduction Your new invent for New Construction manual register is an energy saving and comfort enhancing device. The unit works by replacing

More information

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation

More information

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages. Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water heater for beverages. Model No. Description Reg.No. Part No. HS503 Zip Econoboil 3.0 litre White EB003 103592 HS505

More information

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

MaxLite LED VAPOR TIGHT LINEAR FIXTURES A cost effective LED Vapor Tight Fixture features a full length polycarbonate lens and a one-piece white glass reinforced polyester (GRP) body. Designed to meet or exceed seven to 10 foot-candles at 8

More information

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on You can rely on User Guide and Important Warranty Information Suprima HE Range Condensing Central Heating Boiler Please keep these instructions in a safe place. If you move house, please hand them over

More information

Installation and Servicing Instructions. Alpha CB50

Installation and Servicing Instructions. Alpha CB50 Installation and Servicing Instructions Alpha CB50 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boiler with Unvented Hot Water Storage For Technical help or for Service call... ALPHA

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS U S E R M A N U A L Models: PM15F (shown) PM15P SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: 610-262-6090 Northampton,

More information

TrueClean ToteCleaner

TrueClean ToteCleaner TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....

More information

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 built on innovation acb 30 & 35 Active Chilled Beam Models ACB30 & ACB35 are designed for installation in the ceiling

More information

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE WATERHEATER MANUFACTURERS ASSOCIATION Tel 01952 257963 Fax 01952 253452 Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE www.telford-group.com STAINLESS PRODUCTS Tornado &

More information

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions IOM-573 This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No 53 416 06 Publication No. ZZ 180/17 May 2000 These appliances are tested and certified by B G Technology for

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

Instantaneous Electric Over-Sink Hand Wash Installation and User Instructions

Instantaneous Electric Over-Sink Hand Wash Installation and User Instructions 3 Flow Instantaneous Electric Over-Sink Hand Wash Installation and User Instructions IMPORTANT This Step-by-Step guide should be given to the customer after installation and demonstration. CONTENTS 1.

More information

Installation and Maintenance "L" and "LS" Series

Installation and Maintenance L and LS Series Installation and Maintenance "L" and "LS" Series IB-43-E This bulletin should be used by experienced personnel as a guide to the installation and maintenance of "L" and "LS" Series ultra capacity float

More information

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe. User Guide and Important Warranty Information Suprima 30-80 HE Condensing Central Heating Boiler Please read this document and keep it safe. It will help you out should your boiler need attention. Introduction

More information

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

- User Brochure tekmarnet 4 Setpoint Control 161

- User Brochure tekmarnet 4 Setpoint Control 161 - User Brochure tekmarnet 4 Setpoint Control 161 U 161 08/07 Congratulations on the purchase of your tekmar setpoint control with communication. The setpoint control combines easy-to-use programming with

More information

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4

More information

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle USE AND CARE GUIDE FOR MODEL MEK1, MEK15 Express Cordless Kettle IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed, including the following: 1. Read

More information

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water Installation and Operating Instructions Zip Hydroboil Filtered instant boiling water 01552 Zip Hydroboil 1.5 Litre White 01551 Zip Hydroboil 1.5 Litre Stainless Steel 03552 Zip Hydroboil 3 Litre White

More information

USER MANUAL RANGE HOOD CG920FGS. User manual_cg920fgs 28/11/2012

USER MANUAL RANGE HOOD CG920FGS. User manual_cg920fgs 28/11/2012 USER MANUAL RANGE HOOD CG920FGS 2 4 5 8 8 9 10 11 DESCRIPTION OF YOUR RANGEHOOD RANGEHOOD DIMENSIONS 1 2 20mm 280mm 540mm Min 820 Max 110mm 4 54mm 5 6 500mm 7 500mm 900mm Fig.4 8 Fig. Components list 1.

More information

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts ISO 9001 BX Series Installation, Operation, Maintenance Instructions & Spare Parts WARNING WARNING. The BX convection heater is a heavy duty baseboard designed for use in industrial environments and is

More information

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer. User s Guide BS116 Thank you for purchasing the VACMASTER BS116 Impulse Bag Sealer. You are about to advance your operation with one of the most reliable sealers available. The BS116 is a fully automatic,

More information

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series) Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand how to safely operate

More information

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592 User, Installation and Servicing Instructions Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592 INSTALLATION AND SERVICING INSTRUCTIONS Please read the following carefully before commencing work on

More information

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens. Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water for canteens and kitchens. 103592 Zip Econoboil 3.0 litre White HS503 105592 Zip Econoboil 5.0 litre White HS505

More information

Unpacking Your Fan 2.

Unpacking Your Fan 2. Excel Lighting & Manufacturing Ltd. Lifetime Limited Warranty Excel Lighting & Manufacturing Ltd. Warrants the fan motor to be free from defects in workmanship and material present at time of shipment

More information

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler User s Operating Instructions Baxi Combi 05 HE Gas Fired Wall Mounted Condensing Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

Installation Instructions / Warranty. Massaud

Installation Instructions / Warranty. Massaud Installation Instructions / Warranty Massaud 18450001 Axor Massaud Free-Standing Tub Filler 18450001 Technical Information Max. incoming water pressure 145 psi Recommended water pressure 14.5-72 psi Max.

More information

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual aquamanta TM the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual Technical Information Model Wattage Aquarium Volume CH 025 CH 050 CH 100 CH 150 CH 200 CH 300 25W

More information

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler User s Operating Instructions Baxi System 100 HE Plus Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler Please keep these instructions safe. Should you move house, please hand them

More information

Sema thermostatic bar mixer Installation and operating instructions

Sema thermostatic bar mixer Installation and operating instructions Sema thermostatic bar mixer Installation and operating instructions Installers please note these instructions are to be left with the user 2180579A September 2006 CONTENTS Page Introduction 1 Safety warnings

More information

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS G R A N T C Y L I N D E R & S T O R E R A N G E High Efficiency Direct and Indirect Hot Water Storage Solutions FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS GRANT DUOWAVE

More information

TrueClean ToteCleaner

TrueClean ToteCleaner TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....

More information

THERMOSTATIC SHOWER VALVE

THERMOSTATIC SHOWER VALVE V8/3 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL INSTALLER Please leave manual with user for future reference to unit operation and maintenance. 1 INTRODUCTION Meynell mixing valves are manufactured within

More information

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Instruction Manual. AcuRite Atlas Outdoor Device model 06059 Instruction Manual AcuRite Atlas Outdoor Device model 06059 How It Works Set Up Your AcuRite Atlas AcuRite Atlas is an environmental monitoring station that delivers key information on current outdoor

More information

USER MANUAL SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS USER MANUAL Model: PM50 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067

More information

MaxLite LED Vapor Tight Linear Fixture

MaxLite LED Vapor Tight Linear Fixture General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM D-tect Systems 11814 South Election Road, Suite 200 Draper, UT 84020 www.dtectsystems.com 1 Introduction The mini

More information

Installation and Operating Instructions for Microlene Underbench System

Installation and Operating Instructions for Microlene Underbench System Installation and Operating Instructions for Microlene Underbench System WARNING : Microlene underbench system installation must be in compliance with all local legislative requirements, and installed by

More information

Installation and Servicing Instructions. Alpha CD50

Installation and Servicing Instructions. Alpha CD50 Installation and Servicing Instructions Alpha CD50 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency, Condensing Combination Boiler with Unvented Hot Water Storage For Technical help

More information

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH Zephyr 16 DC FAN WELCOME Thank you and congratulation for choosing an EcoAir DC Fan to help you improve the air quality within your home. Inside you will find many helpful tips on how to use and maintain

More information

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions User s Operating Instructions Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move

More information

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER AIRE Thermostatic bath shower mixer Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180427C October 2005 CONTENTS Page Introduction 1 Safety

More information

LETTER FROM THE FOUNDERS

LETTER FROM THE FOUNDERS LETTER FROM THE FOUNDERS We sleep for one third of our life. Assuming we live 75 years, that s 25 years asleep. This is the time when we recharge our bodies to take on the next day, and refuel our brains

More information

Thanks for shopping with Improvements! Solar Pool Heater XF Item #

Thanks for shopping with Improvements! Solar Pool Heater XF Item # Thanks for shopping with Improvements! Solar Pool Heater XF Item # 417912 To order, call 1-800-642-2112 West Chester, OH 45069 If you have any questions regarding this product, call 1-800-642-2112 and

More information

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit 7215 3200-02/2006 GB (EN) For the user Users Manual Gas wall hung Boiler condensing Buderus 500-24/S Please read thoroughly before operating the unit Introduction Please read these instructions and follow

More information

U S E R M A N U A L UBH1RF HEAT ALARM

U S E R M A N U A L UBH1RF HEAT ALARM U S E R M A N U A L UBH1RF HEAT ALARM OverView This heat alarm is a fire detection and alarm device which gives off an audible and visual warning when the ambient temperature reaches 54 C to 70 C. These

More information

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600 I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d Model code: BORA600 Contact Caple on 0844 8003830 or for spare parts www.4caple.co.uk 1 Y O U R A P P L I A N C E Thank you for buying your

More information

30KW ELECTRIC FAN HEATER

30KW ELECTRIC FAN HEATER 30KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7030 PART NO: 6935458 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

Instantaneous Electric Over-Sink Hand Wash Automatic no-touch model. Installation and User Instructions

Instantaneous Electric Over-Sink Hand Wash Automatic no-touch model. Installation and User Instructions 3 Sense Instantaneous Electric Over-Sink Hand Wash Automatic no-touch model Installation and User Instructions IMPORTANT This Step-by-Step guide should be given to the customer after installation and demonstration.

More information

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation. Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator

More information

ADVANCE ELECTRIC THERMAL STORE

ADVANCE ELECTRIC THERMAL STORE ISSUE 13 1118 INSTALLATION AND USER GUIDE ADVANCE ELECTRIC THERMAL STORE ADVANCE APPLIANCES LTD HOUSEHOLDER PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. 2 INTRODUCTION Advance thermal

More information

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION G Series (Model B) Convector Heater for Hazardous Locations Type G-Series Convection Heaters are designed for use in Class I, Div. I hazardous environments. Units without control options are suitable for

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater Please leave these instructions with the user MULTIPOINT FF Room Sealed Fan-Assisted Water Heater User Operating, Installation and Servicing Instructions 6 720 607 160 (04.02) JS Natural Gas Main Multipoint

More information

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration. MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK IMPORTANT: This booklet should be given to the customer after installation and demonstration. Description of water heater 1) Hot water outlet 2) Temperature

More information

WARRANTY AND INSTRUCTIONS

WARRANTY AND INSTRUCTIONS WARRANTY AND INSTRUCTIONS MODEL NO: SWSS 12 SALTON CERAMIC HAIRSTYLER STRAIGHTENS.FROM WET Thank you for purchasing the SALTON Ceramic Hair-Straightener (Model SWSS 12). This appliance has been designed

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Greenstar 12i/24i System

Greenstar 12i/24i System USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 12i/24i System WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS BOILER IS USED WITH

More information

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living 1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL Design for living 1845 Tech Manual.qxd 23/11/05 1:21 pm Page 3 TECHNICAL DATA & INSTALLATION INSTRUCTIONS

More information

Dene Bath Shower Mixer

Dene Bath Shower Mixer Dene Bath Shower Mixer Installation and operating instructions The showerhead and hose supplied with this product are an integral part of the safety of your shower. Failure to use genuine Triton parts

More information

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER NENE Thermostatic bar mixer shower Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180430B October 2005 CONTENTS Page Introduction 1 Safety

More information

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler 0 4 You can rely on User Guide and Important Warranty Information Performa 4 Eco HE Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk

More information

Model pictured: ST6001

Model pictured: ST6001 ST6001 Issue: 1 Description: ROBINHOOD SUPERTUB SGL DRW Model Number: ST6001 All dimensions in mm Model may vary slightly from images pictured Model pictured: ST6001 1 Overview Contents of packaging: 1

More information