1 FAMSUN SDZB3000 Zoned Belt Dryer Quick Manual For operation and maintenance Has no legal effect Please refer to the product instruction for more information
2 Catalog: 1.Maintenance of the air duct system 2.Maintenance of the steam pipeline 3.Maintenance of the conveyer belt/arch breaking /fine screw reducer/bearing 4.Maintenance of the recirculation fan 5.Maintenance of the air exhausting fan 6.Maintenance of other parts 7.Postscript of some points
3 1.Maintenance of the air duct system Belt dryer SDZB 3000 is zoned and horizontal, the drying media is heated air, adopts crossflow drying method (hot air flow through feed material vertically), to realize heat and water exchange between the feed material and hot air, and take extra water away from the product. The air circulation is shown in the following figure: In this air duct system, part of the hot and moist air is exhausted by the air exhausting fan, meanwhile, dry air flows into the dryer from the make-up air vent from the ambient, the two airflow mix and heated by heat exchanger, then dragged by the recirculation fan and flow to the lower drying chamber to begin the new cycle. Because the product is made of powder, it is unavoidable that powder and cotton-like debris will be blown to the air network, especially will accumulate on the filter and increase the pressure loss, the effect of the dryer will be reduced finally when the accumulated debris reach a certain extent.
4 The above picture shows the situation of filter blockage when it is lack of regular cleaning, it will greatly reduce the dryer's production rate if debris accumulate on the filter like the above picture shows. It's suggested to inspect the filter every week/half a month in the debugging period, and clean the residuals in the air duct as well. After debugging, based on the real situation (the formula, the volume and density of debris, etc) to decide the cleaning cycle. Besides, it's needed to check if the make-up air vent is blocked, if the vent is on the side, engineer can take a look on the ground, while
5 if it is on the top, it's required to inspect whether it is blocked or stuck by foreign stuff periodically (every month is suggested). Some customers may add filter on the top vent, it's needed to check and clean periodically. There will be accumulation of pellets after a period of time, need to be clean periodically. Summary: engineer should be focused on the following aspects of the dryer's air network. Maintenance Examine Content Examine Cycle Filter Make-up air vent Air duct cleaning Heat exchanger's cleaning Dismantle the filter, clean it with compressed air/broom, make sure it's out of cotton-like debris pasted on. Clean the make-up air vent, keep the wind path clear. Clean the accumulation of pellet in the air duct. When the filter is dismantled, clean the middle area between filter and heat exchanger if there are debris, besides, clean the fin of heat exchanger if there During debugging period, every week/half a month; After debugging, decide the period based on the real production situation. Every month. At the same time of the filter's cleaning. At the same time of the filter's cleaning.
6 are pasted stuff with compressed air. 2.Maintenance of the steam pipeline Make sure the steam pipelines are installed in strict accordance with the construction drawing, and work smoothly. The long period maintenance of steam pipeline include the following work: 1)Maintenance of the proportional valve Check every week and drain the filter. Proportional valve is the core components of the whole steam pipeline, because the compressed air is unstable at customer site(high humidity), it's easy to break down after long period of time. Therefore, please strictly follow the "A Guide To The Debugging And Inspecting Of FAMSUN Dryer(SDZB)" to install and operate. Be sure to drain the filter of the proportional valve every week. Besides, please DO NOT add lubricant to the pneumatic two couplet which is installed before the proportional valve. Lubricant will accelerate the damage!
7 2)Maintenance of the filters in pipelines All the core valves (pressure reduction valve, drain valve, proportional valve, etc.) have filters at the upstream of them nearby, to guarantee the core valves' stable performance. Because the quality of To clean the filters every month is suggested. steam is unstable( impurities from the boiler, duct corrosion, etc.),
8 impurities will accumulate in filters during production, and result in slow heating rate and affecting the dryer's production rate. Therefore, it's suggested to clean the filters every month. To sum up: should be focused on the following aspects when maintaining the steam pipeline system: Maintenance Examine Content Examine Cycle Proportional valve Filter Make sure the quality of the compressed air, drain the filter periodically. Clean the impurities of filters periodically to guarantee the pipeline is unblocked. Once a week. Once a month. 3. Maintenance of conveyer belt/arch breaking/fine screw reducer/bearing 1)Reducer SDZB3000 adopt brand reducer of a German company, the failure rate is low, it's suggested to maintain the reducer according to the instruction of the reducer. 2)Bearing The bearings for conveyer belt/arch breaking/fine screw are all mounted, the running speed is low, so it's suggested to add Lithium grease every 1-3 months, the recommend grease is No.2 Lithium grease. 3)Other suggestions Make sure to pay attention to the tautness of the conveyer belt, and execute the following maintenance work: 1.Inspect if the chain is on the middle of the track;
9 2.Inspect if the screen mesh is broken; 3.Adjust the tautness of the chain. Inspect if the chain is on the middle of the track regularly Maintenance Examine Content Examine Cycle Mounted bearings Conveyer belt Add Lithium grease regularly, check if the bears work functionally without abnormal noise. 1. Check the alignment of the chain; 2. Check if the screen filter is broken; 3.Check the tautness of the chain. Add Lithium grease every 3 months, check the bearings at the same time. Every month.
10 4.Maintenance of the recirculation fan 1)Maintenance of the recirculation fan motor The recirculation fan is directly driven by the motor, it is necessary to maintain the motor as a routine, more specifically, applying grease on the bearings periodically as the following table: About the grease type, it's suggested as follows: 1. Must be good quality lithium-based grease; 2. The viscosity should be CST at 40 ; 3. concentration level NLGL2 or 3; 4. Temperature range from -30 to 120. If not specified, the maintenance of motor can be as follow: For motor less 10hp/7.5kW, clean condition, once every 5 years;for motor from 15hp/11kW to 40hp/30kW, clean condition, once every 3 years. For motor running at unclean condition or 24hr a day, divide the interval time by 4; DO NOT OVER-Lubricate. 2)Maintenance of fan blade After a long time running, the fan blades will gather lots of powders and will vibrate, as shown in the following figure:
11 Once the fan blades gather lots of powders, it will cause unnecessary vibration and damage the associative parts. Periodical check and cleaning is recommended. Maintenance Examine Content Examine Cycle Fan blades Check if the fan blades have powders stuck, and clean it. Every month. 5 Maintenance of the air exhausting fan 1)Motor of the exhausting fan's mainenance The maintenance of motor is the same as the motor of recirculation fan motor, refer to chapter 4.
12 2)Maintenance of the fan 1 After the installation, each fan should have a maintenance record, based on which the fan is inspected and maintained. At least one maintenance a year is required regardless of the type of fan. 2 Every 3-month continuous operation, inspect the rolling bearing, roller, surface of roller and inner ring fitting, replace grease (or oil).for grease, it's recommended to fill 2/3 of the bearing, while for oil please refer to the oil level meter. 3 Periodical exhausting fan maintenance, clean dust and dirt inside the fan. 3)3 V belt inspection and adjustment It is necessary to inspect and re-tension the V belt regularly. Pay attention if there are powder accumulation and prick or hindrance, all of these will cause abrasion and belt aging. Remove prick timely, avoid powder into the bearing, check the belt wear and replace new belt if it's worn. If asymmetric abrasion is found, please check if the belt is not well aligned and adjust it. Maintenance Examine Content Examine Cycle Rolling bearing of the fan Fan blades Inspect the rolling bearing, roller, surface of roller and inner ring fitting, replace grease (or oil). Check if there are powder gathered on the blades, and clean it. Every 3 months. Every month. 6.Maintenance of other parts Maintenance Examine Content Examine Cycle Sensors Check if the sensors work functionally and clean the Every month.
13 Electrical connection sensors periodically Check wires are well connected and in good tautness. Every 3 months. 7.Postscript of some points 1)Regular maintenance of the compressed air: A complete compressed air generation system should include the above devices, the maintenance must strictly follow the instruction to guarantee the stable performance of other related devices. 2)Highlight of device maintenance: It's forbidden to run the conveyer belt reversely, make sure the conveyer belt and the outlet material positioner are operated in chain, once the conveyer belt is run reversely or it's not operated in chain with the positioner, irreversible damage will be caused on many components. Therefore, please DO NOT change the motor wire connecting and control system privately. If fault occur on the motor, after dismantled repair and reinstall, please pay more attention on the rotation direction of the motor.
LDDC Series Double-Deck Drum Pre-cleaner. Instruction Manual LAMBTON MACHINERY(ZHENGZHOU)CO. LTD
LDDC Series Double-Deck Drum Pre-cleaner Instruction Manual LAMBTON MACHINERY(ZHENGZHOU)CO. LTD. 2015.08 Index Double-Deck Drum Pre-cleaner... 1 Instruction Manual... 1 Ⅰ. General Introduction... 3 Ⅱ.
More informationHow about Savings in Time, Money, Energy and Longer Life?
Chapter 17: The Value of Maintaining Evaporative Cooling Equipment 97 The Value 17 of Maintaining Evaporative Cooling Equipment 1. Cooling Tower Maintenance and Upgrades... What s in it for You? How about
More informationHORIZONTAL MULTISTAGE CENTRIFUGAL PUMP
HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug
More informationIndholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL
Indholdsfortegnelse Danvent Air Handling Units SERVICE MANUAL Service Servicing of the Air Handling Unit Your ventilation system is equipped with a Danvent Air Handling Unit (AHU) which will contribute
More informationPocket Hardmount. Preventative Maintenance.
Pocket Hardmount Preventative Maintenance www.comlaundry.com Part No. 7-04-49 November 2005 Table of Contents Daily...2 Beginning of the Day...2 End of the Day...4 Weekly...6 Monthly...7 Quarterly...11
More informationTLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL
TLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL Contents 1. Introduction... 3 1.1 Features... 3 1.2 Specifications... 3 2. Installation... 3 3. Machine explosion drawing... 4 4. Equipment
More informationMTM. Trapezium Mill. Shanghai Shibang Machinery Co., Ltd
MTM Trapezium Mill Shanghai Shibang Machinery Co., Ltd Shanghai Shibang Machinery Co., Ltd. Overview MTM Medium Speed Trapezium Mill adopts numbers of national patents, such as trapezium working surface,
More informationEYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator
USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G User Manual for EYS 01G Screw-Press Separator Table of Contents Page 1. Introduction 2 2. General Safety Instructions 3 3. Installation 5 4. Start-up
More informationRefrigerated Compressed Air Dryer
Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED
More informationSPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS
SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification
More informationMaintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently
Part One How to Maintain a TOWER of POWER Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently BY GLENN A. BABCOCK The cooling tower is often the forgotten component
More informationPELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian
PELLET MILL N-MIDI pellet mill machine is projected and manufactured in accordance with CE norm about construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian
More informationLaminator ZJY Series User Manual
Laminator ZJY Series User Manual Eastsign International Limited Room 1818, 18/F., Shatin Galleria, 18-24 Shan Mei Street, Fotan, Shatin, N.T., Hong Kong TEL: + 852-2117 0098 FAX: + 852-2117 0099 Website:
More informationMOULD WITH ENTERING PUNCHES
SACMI MOLDS&DIES MOULD WITH ENTERING PUNCHES INSTRUCTION MANUAL 1-1 GENERAL WARNING This manual is part and parcel of the product. Carefully read the instructions of the manual as they give important information
More informationCHAPTER 1 SAFETY SUMMARY CHAPTER 2 MACHINE FAMILIARIZATION CHAPTER 3 UNPACKING AND INSTALLATION CHAPTER 4 OPERATION INSTRUCTION
===== CONTENTS ===== CHAPTER 1 SAFETY SUMMARY 1-1 INTRODUCTION 3 1-2 SAFETY DURING INSTALLATION 3 1-3 SAFETY DURING OPERATION 3 1-4 PRECAUTIONS DURING OPERATION 4 1-5 SAFETY DURING MAINTENANCE 4 1-6 SAFETY
More informationWhat is a Closed circuit Cooling Tower (CCT)?
What is a Closed circuit Cooling Tower (CCT)? Closed circuit Cooling Towers are hybrids that pass the working fluids through a tube bundle, upon which clean water is sprayer and a faninduced draft applied.
More informationCHAPTER 1 SAFETY SUMMARY CHAPTER 2 MACHINE FAMILIARIZATION CHAPTER 3 UNPACKING AND INSTALLATION CHAPTER 4 OPERATION INSTRUCTION
===== CONTENTS ===== CHAPTER 1 SAFETY SUMMARY 1-1 INTRODUCTION 3 1-2 SAFETY DURING INSTALLATION 3 1-3 SAFETY DURING OPERATION 3 1-4 PRECAUTIONS DURING OPERATION 4 1-5 SAFETY DURING MAINTENANCE 4 1-6 SAFETY
More informationRTP9 ROTARY TABLET PRESS USER MANUAL
RTP9 ROTARY TABLET PRESS USER MANUAL LFA Tablet Presses is a trading name of LFA Machines Oxford LTD All of the content in this document is covered by copyright CONTENTS Page 1. Introduction Page 1. Technical
More informationPulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities
Pulse Jet ASTEC PULSE JET BAGHOUSE for Asphalt Facilities ASTEC PULSE JET BAGHOUSE FOR ASPHALT MIXING PLANTS Astec baghouses deliver superior performance and efficiency, while helping your plant meet
More informationInstructions for the Use and Care and Installation of ORW6XA ORW9XA. Wall Canopy Rangehoods
Instructions for the Use and Care and Installation of ORW6XA ORW9XA Wall Canopy Rangehoods CONTENTS 1 Notice 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7 Maintenance
More informationTHERMAL SYSTEMS, INC. Installation and Operation Manual
THERMAL SYSTEMS, INC. Installation and Operation Manual Revised September 2016 1. GENERAL SAFETY INFORMATION 1.1 Specification Never exceed the maximum allowable temperature or pressure ratings. Never
More informationOPERATION AND MAINTNENCE MANUAL
OPERATION AND MAINTNENCE MANUAL VPI QUALITY WINDOWS 3420 E Ferry Ave. Spokane WA. 99202 TABLE OF CONTENTS Part 1) Storage and Handling... 2 Part 2) Installation, Protection and Initial Cleaning... 2 Part
More informationInstructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods
Instructions for the Use and Care and Installation of ORC97G ORC98G Glass Canopy Rangehoods CONTENTS 1 Notice 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7 Maintenance
More informationJENROLL EXPG the gas-heated, self-contained ironer
JENSEN Integrated gas-fired burner and heat exchanger Short heating time and stand-alone operation Thermal fluid oil as heating medium NEW Flexible chest design Optimised output Combines the well-known
More informationRust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution
Rust, corrosion and leakages threaten even the best distribution network Only Quality Air Solutions keep your air distribution in optimal shape Improve your business productivity, Why? Customer benefits
More informationOPERATOR S MANUAL. For BURLY ATTACHMENTS
OPERATOR S MANUAL For BURLY ATTACHMENTS April 4, 2018 Clod-Buster Topsoil Screener LIMITED WARRANTY Burly Attachments, LLC warrants to the original Purchaser, all products, manufactured by it, to be free
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationIMCE-250 EXTRUSION LINE MACHINE
IMCE-250 EXTRUSION LINE MACHINE INTERNATIONAL MACHINE CONCEPTS WELCOMES YOU TO YOUR NEW MACHINE Operation Manual: Date 2017 CONTENTS Chapter 1 Machine Description 1.1 Uncrating Instructions 1.2 Installation
More informationDrive Power and Torque in Paper Machine Dryers
Drive Power and Torque in Paper Machine Dryers 2 nd Edition Gregory L. Wedel President Kadant Johnson Inc. Gerald L. Timm Vice President, Research & Development Kadant Johnson Inc. Technical White Paper
More informationDrying Tumblers Pound Capacity
Drying Tumblers 25-170 Pound Capacity Preventative Maintenance Please refer to your operating manual for detailed maintenance procedures. www.comlaundry.com Part No. 70323301R6 December 2009 Table of
More informationtech-info Continuous centrifugals of the K3000 series Fields of application: The BMA continuous centrifugals of the
tech-info Continuous centrifugals of the K3000 series Fields of application: The BMA continuous centrifugals of the new K3000 series are used in the cane and beet sugar industries, and also in sugar refineries.
More informationDowntime Instructions
user manual Downtime Instructions MECHANICAL DRAFT COOLING TOWERS Z0238848_C ISSUED 8/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT Preface Proper preventive maintenance
More informationAgilent Dissolution Seminar Series
Agilent Dissolution Seminar Series The Dissolution Apparatus Drive unit Paddle shaft Locking rings Touch screen Water bath Vessel plate Lift mechanism DISSOLUTION APPARATUS Support plate Water heater/circulator
More informationcooling tower downtime instructions
USER MANUAL cooling tower downtime instructions M92-1308A ISSUED 4/2013 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. instructions for downtime Mechanical Draft Cooling
More informationTYPE FSD KYOWA EXHAUST GAS SCRUBBER OPERATION MANUAL
1 TYPE FSD KYOWA EXHAUST GAS SCRUBBER OPERATION MANUAL THAI KYOWA KAKO CO.,LTD. WWW.KYOWA.CO.TH 2 CONTENTS 1.SPECIFICATIONS... 2 2.EXTERNAL VIEW.. 3 3.FUNCTION OF EACH SECTION 4 4.SAFETY CONTROL AND SAFETY
More informationEnviro KES INSTALLATON MANUAL
Enviro KES INSTALLATON MANUAL Spring Air Systems Inc., Oakville, Ontario Phone (905) 338-2999, Fax (905) 338-0179, info@springairsystems.com www.springairsystems.com KES Installation Manual. This publication
More informationChapter 5 Inspection and maintenance
Basic guide Chapter 5 Inspection and maintenance Platinous J series Chapter 5 Inspection and maintenance This chapter describes how to perform regular inspection and maintenance to ensure the long operating
More informationBoretech China Make, Pet Bottles Recycling Line Ref Id SM4325 (Details-Specification mentioned hereunder are for indicative purpose only) DESIGN DATA 1.1 Capacity - PET bottles input : 1,500 kg/h - Dry
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended
More informationAXPR Wall Mounted Axial Panel Fans
Bulletin 78-January-03-06 AXPR Wall Mounted Axial Panel Fans INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This publication contains the installation, operation and maintenance instructions for the AXPR
More informationOperating instructions
Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen
More informationA Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)
A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio 45014-2035 Phone: (513) 874-2400 Fax: (513) 870-6249 JM AEROFOIL FANS Installation, Operation and Maintenance Instructions Site Storage The fan must
More informationOWNERS MANUAL ST50BT
OWNERS MANUAL ST50BT NaceCare Solutions 1205 Britannia Road East, Mississauga, ON L4W 1C7 Phone: 1-800-387-3210 Fax: 1-800-709-2896 SUMMARY SUMMARY...2 ON CONSIGNMENT OF MACHINE...3 INTRODUCTION...3 MACHINE
More informationReasons for reissue are provided in Section 6, REVISION SUMMARY. Figure 1. Figure 2
Each tool features outer and inner crimping dies (contained within the crimper and anvil jaws) and a CERTI CRIMP ratchet. The outer crimping dies crimp the insulation barrels of the splice and the inner
More informationTECHNICAL INFORMATION T 15xx Dryers
TECHNICAL INFORMATION T 15xx Dryers 2010 Miele USA Table of Contents 1.0 2.0 3.0 T 15xx Dryers Construction and Design... 5 1.1 Appliance Overview Vented Models... 5 1.2 Appliance Overview Condenser Models...
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING
January 207 80-572 Rev - 2950 Mechanic Street Lake City, PA 6423 USA Phone: -800-840-9906 Fax: 84-774-0778 Email: info@vanairsystems.com www.vanairsystems.com INSTALLATION, OPERATION & MAINTENANCE MANUAL
More informationGLEB Kitchen exhaust fan
GLEB Kitchen exhaust fan Installation and Maintenance??.1.2013 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationPreventative Maintenance Tables
Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit
More informationISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:
ISLAND MOUNT RANGE HOOD This manual is made with 100 % recycled paper. Electronic version of this manual is available at: www.cosmoappliances.com Thank You Thank you for your purchase. We know that you
More informationInstallation and operation Manual
SJZ51/105 Conic Twin Screw Extruder Installation and operation Manual JIANGSU FAYGO UNION MACHINERY CO., LTD Address: No.8 FeiXIANG Road TEL: +86-512-56762818 Economic Development Zone FAX: +86-512-56762800
More informationLONGONI ENGINEERING SRL
INDEX 1.1 Classification of heat exchanger and components 1.1.2 Type of heat exchanger and components 1.2 Purpose and scope of the manual 1.3 General instruction 1.4 Warning installation 1.5 Notes for
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........
More informationFagronLab NP-1 UV. Negative pressure workbench. User Manual
Negative pressure workbench User Manual Table of contents 1. Introduction... 3 2. Service... 3 3. Warranty... 3 4. Application range... 4 5. Main technical parameters... 4 6. Performance index... 5 Vibration
More informationCMHC HOME MAINTENANCE CHECKLIST
Make sure air vents indoors and outdoors (intake, exhaust and forced air) are not blocked by snow or debris. Check and clean range hood filters on a monthly basis. Test ground fault circuit interrupter(s)
More informationORC93XA ORC94XBA. Wall Canopy Rangehoods
Instructions for the Use and Care and Installation of ORC93XA ORC94XBA Wall Canopy Rangehoods CONTENTS 1 Warning 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7
More informationHT650 TM FAN DRIVE SERVICE INSTRUCTIONS
HT650 TM FAN DRIVE SERVICE INSTRUCTIONS When unpacking your product, remove all components and inspect them to ensure that no damage occurred during shipping. If any components are missing or damaged,
More informationKITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE
KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5
More informationService Step by Step Trouble-Shooting Check-List
WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.
More informationThis guarantee is subject to the terms and conditions stated in this brochure.
Appliances Everyday life at home puts high demands on appliances. IKEA appliances are rigorously tested to comply with our strict standards for quality and safety as well as with the highest standards
More informationEchelpoelweg KA Weerselo The Netherlands. Tel. (+31) Fax. (+31)
Echelpoelweg 13 7595 KA Weerselo The Netherlands Tel. (+31) 6 53 33 13 44 Fax. (+31) 8 42 13 93 07 E-mail: info@esico.nl Enabling Simplicity in Construction About us Esico design and manufacture Process
More informationSeries 57 WATER/OIL SEPARATORS
Series 304 WATER AND OIL IN COMPRESSED AIR SYSTEM WATER ACCUMULATION When compressing air, a compressor draws in many other substances including water vapor. The compression process causes this water vapor
More informationINTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC
Operating Manual Tablet Counting and Filling Machine Model IMC-16-1 - CONTENTS 1. Precautions 2. Introduction to the machine 3. Relevant Technical Data 4. Working environment 5. Introduction to the control
More informationWALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:
WALL MOUNT RANGE HOOD This manual is made with 100 % recycled paper. Electronic version of this manual is available at: www.cosmoappliances.com Thank You Thank you for your purchase. We know that you have
More informationOperator Preventive Maintenance
Operator Preventive Maintenance Operator Preventive Maintenance Overview To maintain the Gaylord Ventilator in good working order and to keep the system operating at optimum efficiency, preventive maintenance,
More informationMANUAL SWEEPER GUIDE. Model 920. Please make sure you read the instruction manual below and clear the operation before you use this sweeper.
MANUAL SWEEPER GUIDE Model 920 Please make sure you read the instruction manual below and clear the operation before you use this sweeper. SPECIFICATION HOW TO USE Working width with two side brushes 920
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationTECHNICAL INFORMATION T1500 Series Clothes Dryers
TECHNICAL INFORMATION T1500 Series Clothes Dryers 2003 Miele - Table of Contents 1.0 CONSTRUCTION & DESIGN 1.1 Appliance Overview - Vented 1 1.2 Appliance Overview Condenser Models 2 1.3 Controls Overview
More informationEBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationZBJ Press. Operation Manual
ZBJ Press Operation Manual ZJB 50 Stick fuel forming machine I. Use and features This machine is made up of the heating collar,propeller,forming cylindar,inner wear sleeve thermocouple,body and the stand
More informationEN l Senking Batch Transfer Drying Tumbler DT Senking Batch Transfer Drying Tumbler DT High performance with less energy
EN l Senking Batch Transfer Drying Tumbler DT 60 240 Senking Batch Transfer Drying Tumbler DT 60 240 High performance with less energy Single dryer with loading belt. directly side by side. The dryers
More informationPELLET MILL. developed properly for pellet production and all technologies and mechanical solutions are chosen to
PELLET MILL N-ECO pellet mill machine is projected and manufactured in accordance with CE norm about construction s prescriptions and safety. With N-ECO you will save money and get lower pellet production
More informationWALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:
WALL MOUNT RANGE HOOD This manual is made with 100 % recycled paper. Electronic version of this manual is available at: www.cosmoappliances.com Thank You Thank you for your purchase. We know that you have
More informationSheetfed offset technology. KBA Rapida 75. Technical information. Koenig & Bauer AG
Sheetfed offset technology KBA Rapida 75 Technical information Koenig & Bauer AG Technical information Ultra compact, user-friendly, space- and energy-saving Feeder and infeed Feeder New KBA high-performance
More informationPumps SELECTION OF A PUMP
Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL
CENTRAL FANS COLASIT LTD Unit 12A, Palmers Road, East Moons Moat, Redditch. Worcs. B98 0RF Tel: 01527-517200 Fax: 01527-517195 Edition 04_13 INSTALLATION, OPERATION & MAINTENANCE MANUAL CIV Fan Range Valid
More informationAir treatment solutions. Aftercoolers & condensate treatment
Air treatment solutions Aftercoolers & condensate treatment RELIABLE AND CLEAN AIR Atlas Copco aftercoolers and condensate treatment The air that leaves a compressor reaches 100% humidity. It also contains
More informationHeavy Head Hand Crimping Tools (HHHT) [ ]
Heavy Head Hand Crimping Tools (HHHT) 220015-[ ] Instruction Sheet 408-2331 19 APR 12 PROPER USE GUIDELINES Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools.
More information3 in 1 Garden Vacuum 9255 Instructions for Use
Leaf Blower-Vac/Patio Cleaner Technical Specifications Model GY 8113 Rated voltage 230V Rated frequency 50Hz Rated power consumption 3000W Mains fuse(delayed action) 13A Speed 15000 rpm Max. blower air
More informationISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:
ISLAND MOUNT RANGE HOOD This manual is made with 100 % recycled paper. Electronic version of this manual is available at: www.cosmoappliances.com Thank You Thank you for your purchase. We know that you
More informationFMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL
FMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL I. Specifications Heating Mode: Upper roller heating Heating power: 1500W Rated Power: 16A II.
More informationEHA Hoffmann International GmbH
EHA Hoffmann International GmbH User manual EHA-TRANSPRINT HP 2020 Machine-No.: Year: EHA Hoffmann International GmbH Michelsbergstraße 24 D-57080 Siegen/Germany Telephone: +49 271 39 32-0 Telefax: +49
More informationPelletizing System Options for Extrusion
Pelletizing System Options for Extrusion by Dana Darley Extrusion Auxiliary Serv ices Dacula, GA (678) 714-5218 www.extrusionauxiliary.com Types of Pelletizing Systems Strand Water Bath Strand Water Slide
More informationOK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.
INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance
More informationLaminator II.WARM User Manual
Laminator II.WARM User Manual Eastsign International Limited Room 1818, 18/F., Shatin Galleria, 18-24 Shan Mei Street, Fotan, Shatin, N.T., Hong Kong TEL: + 852-2117 0098 FAX: + 852-2117 0099 Website:
More informationOperating Instruction SAND MAKING MACHINE. Henan Hongxing Heavy Machinery Co., Ltd.
Operating Instruction SAND MAKING MACHINE Henan Hongxing Heavy Machinery Co., Ltd. Overview Vertical shaft impact crusher is also called sand maker which is highly efficient stone crushing equipment with
More informationISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:
ISLAND MOUNT RANGE HOOD This manual is made with 100 % recycled paper. Electronic version of this manual is available at: www.cosmoappliances.com Thank You Thank you for your purchase. We know that you
More informationINSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS
INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS AIRVAC INDUSTRIES & PROJECTS CORPORATE OFFICE: H-2/111, SECTOR-16, ROHINI, DELHI-110 085 PHONE: +91-11-32958731, 27298061 FAX: +91-11-27298061
More informationMDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual
MDX Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap Operation & Maintenance Manual MODELS MDX 1500 1800 2400 3000 TABLE OF CONTENTS 1.0 GENERAL 2 1.1 How to use this
More informationTECHNICAL SERVICE MANUAL SCALA - SC
TECHNICAL SERVICE MANUAL SCALA - SC MODELS: SCALA 400 - SC 400 SCALA 600 - SC 600 SCALA 1T - SC 1TN SCALA 2T - SC 2TN SCALA 3T - SC 3TN SCALA 5T - SC 5TN SCALA 10T - SC 10TN SCALA 15T - SC 15TN TABLE OF
More informationLEAF REMOVAL & WASHING
capolinea.it Via Don Battistoni, 1-60035 Jesi (AN) Italy Phone +39 0731.2311- Fax +39 0731.231239 www.pieralisi.com - info@pieralisi.com Pictures and technical features are not binding. The company reserves
More informationROTARY SCREW COMPRESSOR CSA 5,5-7, HP
ROTARY SCREW COMPRESSOR CSA 5,5-7,5-10 - 15-20 HP Technology and Performance High performance, silent running, simple installation and maintenance, makes the CSA compressor belong to the top class models
More informationHEATING AND VENTILATION
SECTION 14-102.04 14-102.04/ 1 2007OC19 DESCRIPTION The heating, ventilation and air conditioning (HVAC) system is designed to optimize passenger comfort. The system regulates interior vehicle atmosphere,
More informationOWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS
R O O F T O P N A T U R A L A I R C O N D I T I O N E R S OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS How to Operate Using Your Air Conditioner
More informationASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL
ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL 1 Contents Preface 3 1.1 Safety Guide 4 1.2 Precautions 4 Chapter II 5 Purchase Check, Technical Parameter and Product Description 5 2.1 Purchase Check
More informationSWASTIK ESTABLISHED 1937 KNIT FABRIC COMPACTORS SWASTIK TEXTILE ENGINEERS PVT. LTD.
SWASTIK ESTABLISHED 1937 KNIT FABRIC COMPACTORS SWASTIK TEXTILE ENGINEERS PVT. LTD. Swastik Premises, Amraiwadi, Ahmedabad - 380 026. INDIA Tel. : (+91)(79) 6543 5017, 2274 3553, 2274 9068, 2274 8551,
More informationInstruction Manual. Juice Extractor. Model: ESI Dezembro/2008
Instruction Manual Juice Extractor 36202.6- Dezembro/2008 Model: ESI 5. PROBLEMS ANALYSIS and SOLUTIONS 5. 1 Problems, Causes and Solutions The Juice Extractor Mod. ESI were designed to operate with the
More informationScrew Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig
Screw Compressors SM SERIES Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig Rotary Screw Compressor Maximum Reliability and Efficiency For years, customers have depended on Kaeser for reliable
More informationAMC400A Chocolate Enrober Instruction manual
AMC400A Chocolate Enrober Instruction manual Content Preface Chapter One Safety Instructions Chapter Two Specification and Installation Chapter Three Operation and Usage Chapter Four Repair and Maintenance
More information