Company History Locations Product range References

Size: px
Start display at page:

Download "Company History Locations Product range References"

Transcription

1 Company History Locations Product range References Sirocco 2017

2 Fact Sheet founded in 1888 as a subsidiary of White, Child & Beney London since 1903 distribution of industrial fans under the brand "SIROCCO" of Davidson & Comp - Belfast 1908 start of manufacturing of fans under licence in Vienna 1930 start of manufacturing of heat exchangers 1986 start of manufacturing of tunnel dampers and control flaps 2014 takeover of Sirocco by Schako Holding Switzerland 2015 Sirocco is participating a group of companies with Novenco in the Schako Holding approx 120 employees in the group today mechanical- and plant engineering with a focus on ventilation technology for the process industry and underground transport systems Location Vienna, Austria - Head Office (Engineering/Sales/Marketing/Administration) Location Zabrze, Poland - Production

3 Headquarters Vienna Office/Logistic hall Sirocco Luft- und Umwelttechnik GmbH Adamovichgasse Vienna - Austria Office building: active surface: 850 m² Production hall: active surface: 1000 m² Centralized management of all locations Sales department for domestic & export business Engineering and project management Test facilities for fans and dampers up to 4x4 m Test facilities for dynamic balancing for 2 levels Warehouse for spare parts and logistic department Quality system certified according to ISO 9001:2008

4 Headquarters Poland Production hall Zabrze Sirocco Polska Sp z oo ul ks Doktora Antoniego Korczoka Zabrze - Poland Total area m² Active surface 4000 m² Modern manufacturing facilities Specialized in fabrication of black, stainless and special steel and aluminium up to 5t and assembling of components NC-controlled machines (cutting, forming, bending, spot welding etc), indoor crane 5t, outdoor crane 10t New test facility for dynamic balancing up to 4 m Qualified welders (TÜV) Quality system certified according to ISO 9001:2008

5 About us We are one of the leading companies in industrial ventilation technology Air Technology For more than a century the company has been at the forefront of engineering technology We offer industrial fans and high performance dampers The product range also includes heat exchangers, dust removal systems and engineered solutions for the ventilation of tunnels Service and control are being performed exclusively by highly qualified engineers An extensive check list-catalogue serves as the base for this activity We fulfil the highest demands of our customers due to comprehensive knowhow, decades of experience, a technical special knowledge and the most modern engineering tolls (CAD, Finite element calculation)

6 Product range Control and regulation dampers Industrial fans Heat exchangers Service, Assembling & Spare Parts Tunnel equipment Radial fans Heat exchangers Service Industry Axial fans Cooling units Assembling Marine/ Off-Shore Heat recovery units

7 Control & regulation dampers - Tunnel equipment TRD TUNNEL VENTILATION DAMPERS Are made of high-quality stainless steel (14571) They stand out through their excellent air tightness values and corrosion resistance and can be used in temperatures of up to 400 C HID INDUSTRIAL DAMPERS Are used for general industries The dampers are standardized and used a modular design Extensive Certificates (Fire 4h 1120 C, Operation 400 C) according to international demands HDD SEAL-OFF DAMPERS Manufactured in heavy gauge mild steel, these welded dampers are installed in fan systems as separation and shut off dampers They are suitable for operating temperatures of up to 600 C

8 Control & regulation dampers - Tunnel equipment WSG WEATHER GRID To protect the fans from snow and dirt, stainless steel wire meshes are used in fresh air inlet canals LKE AIR DUCT FIXTURES Diversion vanes are implemented to minimize the flow-loss in duct delays and diversions The radius of the curvature, as well as the number and spacing of the diversion vanes are adjusted to suit the profile in order to guarantee optimal flowthrough conditions MAD MOUNTING COVERS In order to close the openings through which the ventilation systems are brought into the designated spaces, movable mounting covers are used These covers are soundproof and temperature insulated and are manufactured from various materials according to customer requirements

9 Control & regulation dampers - Industry HDD HEAVY DUTY DAMPER Multi-louver dampers manufactured from welded steel plates and feature particularly robust design Temperature resistance: 400 C Leakage rate 007m³/m²/s up to 3000 Pa HDD LIGHT - HEAVY DUTY DAMPER LIGHT Multi-louver damper with bolted frame and blades Leakage rate 01m³/m²/s up to 1000 Pa HID HIGH INTEGRITY DAMPER The modular damper series type HID was developed in accordance with international industrial air standards Multi-louver dampers with welded and bolted frame Material: galvanized steel Modul size up to 2500 x 3000 mm Temperature resistance up to 400 C, Leakage rate 01 m³/m²/s up to 1000 Pa

10 Control & regulation dampers - Industry DDC DIFFERENTIAL DAMPER CONTROL Louver dampers in a heavy design used as control or shutoff dampers for industrial fans In application together with a suction box carried out with stepwise controlled damper blades SVD SINGLE VANE DAMPER Single or multi-louver damper in a heavy duty industrial design with a circumferential flange RVC RADIAL VANE CONTROL The fan wing controller offers much better controlling than throttling with the advantage of higher efficiency when throttling down to smaller angles

11 Control & regulation dampers Marine & Offshore SHIPBUILDING & DRILLING PLATFORM Use as a fire or smoke dampers with relevant marine approvals FIRE SAFETY AND SMOKE CONTROL The valves are used for air separation of individual sections of ships or as drilling platforms Welded and bolted construction with stainless steel blades and wingflap side seals to ensure the requirements of the ship to keep updated Its rigid form of the leaf is a through-penetrating avoided by flames

12 Industrial fans The range of fans includes both radial and axial types Impeller diameters are up to 3 meters ( m³/h with pressure up to 25 kpa and operating temperatures up to 650 C) Application areas: power stations, paper mills, cement and chemical production industries, tunnel and car park applications RADIAL FANS The volume range reaches m³/h at a steadily rising pressure of up to 25 kpa They guarantee a high degree of efficiency, a rugged design and permanent economic operation AXIAL FANS Consist of a rugged, welded housing in which a dynamically balanced impeller (cast aluminum, synthetic material or welded steel construction) is built-in 21 sizes up to m³/h

13 Industrial fans - Novenco NOVENCO CENTRIFUGAL FANS Serial products with volume range up to m³/h and pressure increase of 1500 Pa Housing and impeller in galvanized steel, direct or belt driven NOVENCO AXIAL FANS TYPE NOVAX Standard- and smoke exhaust fan, volume up to m³/h and pressure increase of 2000 Pa Housing in galvanized steel, impeller in alu and fibreglassreinforced polyester NOVENCO AXIAL FANS TYPE ZERAX Standard- and Atex fan with high level of efficiency and low power consumption, volume range up to m³/h and pressure increase of 3400 Pa

14 Industrial fans - Novenco NOVENCO TUNNEL JET FANS Jet fans with impeller diameter up to 1600mm, in round or rectangular outer dimensions, up to flue gas temperatures of 400 C NOVENCO CAR PARK JET FANS For smoke exhaust of car park decks with impeller diameter up to 500 mm, possible with noise reduction system, up to flue gas temperatures of 400 C

15 Heat Exchangers FINE AND TUBE HEAT EXCHANGERS are especially suitable for air and water cooling or heating Tubes made of copper, copper-nickel alloys or stainless steel with fins made of aluminium, copper or stainless steel Design is also available as steam heater BARE TUBE (SHELL AND TUBE) HEAT EXCHANGERS are especially suitable for oil, water and gas cooling or heating Tubes made of steel, brass, copper-nickel alloys or stainless steel SAFETY HEAT EXCHANGERS use a double tube system as an essential feature which prevents the interchange of media in case of leakages Design is available as fin tube- and bare tube-heat exchanger Sirocco 2016

16 Heat Exchangers AIR CIRCULATION COOLER, COOLER HOUSING consist of air/water heat exchangers and cooler housings with built-in fans as well as filters and monitoring devices according to requirements PLATE HEAT EXCHANGER Are especially suitable for water and oil cooling or heating They are built on the counterflow principle and consist of a screwed or brazed stainless steel plate set Sirocco 2016

17 Service & Assembling SERVICE & ASSEMBLING Industrial Fans Tunnel Equipment Heat Exchangers Air Systems Filter Systems

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products NOVENCO BUILDING & INDUSTRY PRODUCTS Products PREFACE To consider the environment in the design and manufacture of ventilation equipment and fans is quite natural and essential for NOVENCO Building & Industry.

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers. ENGIE Refrigeration supplies the right cooling for every process: from efficient chillers and modular re-cooling systems to turnkey solutions such as refrigeration containers or modules. Efficiency, sustainability,

More information

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE ESSENCE Our consideration for the environment in the design and manufacturing of ventilation equipment and fans is a big concern for

More information

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

Air Handling Units. T F E.

Air Handling Units.  T F E. Air Handling Units Extract from BS EN ISO 15138:2007 Petroleum & natural gas industries- Offshore production installations-heating, ventilation & air-conditioning. A.12.1 Function Installations provided

More information

Centrifugal Fans, Non-Overloading, Backward Inclined

Centrifugal Fans, Non-Overloading, Backward Inclined BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010 Novenco jet fans AUO / ARO / AUT / ART / CGF January 2010 Product facts Product Novenco jet fans are produced in unidirectional (AU_ and CGF) and reversible (AR_) versions. AUT/ART circular Basic jet fans

More information

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited 1 more than just a fan supplier The most diverse range of industrial fans & accessories available from a single source... 2 products oem & industrial 3 single inlet centrifugal backward curved centrifugal

More information

Centeral Station Air Handling Unit

Centeral Station Air Handling Unit Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Danvent DV 190 and 240

Danvent DV 190 and 240 Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Danvent DV 190 and 240 Air Handling Units with High Capacity Danvent DV 190

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

R. K. Engg. Works Private Limited

R. K. Engg. Works Private Limited +91-8048600612 R. K. Engg. Works Private Limited https://www.centrifugalfanblowers.com/ We are one of the distinguished manufacturer, exporter and supplier of pollution control equipment and air ventilation

More information

Hi-Pres Cooling Products Catalogue

Hi-Pres Cooling Products Catalogue Sales offices: Novenco Marine & Offshore A/S Industrivej 22 4700 Naestved Denmark Tel:+45 7012 4222 Fax:+45 5575 65 E-mail: info@novencogroup.com Novenco A.S. Karenslyst Allé 11 N-0278 Oslo Norway Tel:+47

More information

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. Page 238219-1 SECTION 238219 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success. BLOWERS With over 70 years of experience and expertise our fans will ensure your projects are a success. ABOUT OUR PARTNERSHIP has been representing Chicago Blower Corporation (USA) since 2004, offering

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

AXIAL & JET FANS FOR TUNNEL VENTILATION

AXIAL & JET FANS FOR TUNNEL VENTILATION AXIAL & JET FANS FOR TUNNEL VENTILATION ZITRON is a world-wide leading company in designing, manufacturing, testing, installing and commissioning complete ventilation systems for road tunnels, railway

More information

Axial flow fan AXICO ANTI-STALL

Axial flow fan AXICO ANTI-STALL Product data sheet: AXICO ANTI-STALL Axial flow fan AXICO ANTI-STALL Model FPAC and FPMC axial flow fans with controllable pitch blades. Air flow range: 3-110 m³/s (10.000 400.000 m³/h). Pressure rise:

More information

Marine Heat Exchangers SALES SERVICE REPAIR

Marine Heat Exchangers SALES SERVICE REPAIR Marine Heat Exchangers SALES SERVICE REPAIR Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PRODUC 104-32 Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL

More information

THE COMPANY. TECHNICAL OFFICE AND PRODUCTION UNITS. Our company has two production units:

THE COMPANY. TECHNICAL OFFICE AND PRODUCTION UNITS. Our company has two production units: THE COMPANY COMPANY PROFILE. 3S Saldature Speciali Segrate Srl was established in 1970. Since from its origin the Company was oriented to the design and production of equipment-components which are widely

More information

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260) Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN 46706 (260) 925-6550 Fax: (260) 925-6093 Industrial Facility Midwest Re: Facility Ventilation Audit Schust Engineering, Inc. is pleased

More information

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION (15820) - AIR DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors

More information

Tunnel Axial Flow Fan

Tunnel Axial Flow Fan Tunnel Axial Flow Fan TUNNEL AXIAL FLOW FAN Tunnel fans are an axial flow fans and moves an airstream along the axis of the fan. The air is pressurized by the aerodynamic lift generated by the fan blades,

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 233516 - ENGINE EXHAUST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Exhaust fans. B. Ductwork and duct fittings. C. Inlet fittings. D. Accessories. E. Carbon monoxide detectors. 1.2 RELATED

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns.

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX010 November 2005 AXIAL POWER ROOF VENTILATORS Power Roof Ventilators Twin City Fan & Blower offers a wide variety of Power Roof Ventilators (PRVs). The PRVs have been

More information

TUNNEL FANS STANDARD AND HOT SMOKE

TUNNEL FANS STANDARD AND HOT SMOKE TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC

More information

HasconWing. Fixed or variable airfoil profile axial impellers

HasconWing. Fixed or variable airfoil profile axial impellers HasconWing Fixed or variable airfoil profile axial impellers Hascon Engineering has been operating in the ventilation field for more than thirty years and our reliable and high quality axial impellers

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation

More information

PRODUCT CATALOGUE. Ventilating and exhausting systems. for:

PRODUCT CATALOGUE. Ventilating and exhausting systems.  for: Ventilating and exhausting systems for: Coal mining Potassium mining Ore mining Tunnel construction Metro tunnels Road building Underground irrigation and cavern systems PRODUCT CATALOGUE www.korfmann.com

More information

Güntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions!

Güntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions! Güntner Info finoox technology fin and tube heat exchangers Tailor-made solutions! Heat exchangers Knowledge-based engineering Special Air Conditioning and Refrigeration applications and the cooling of

More information

AGRICULTURE AND FORESTRY CONSTRUCTION AND MINING AUTOMOTIVE, COMMERCIAL VEHICLES AND RAILWAYS INDUSTRIAL EQUIPMENT

AGRICULTURE AND FORESTRY CONSTRUCTION AND MINING AUTOMOTIVE, COMMERCIAL VEHICLES AND RAILWAYS INDUSTRIAL EQUIPMENT RAAL is a manufacturer of complete cooling systems and heat exchangers, made of aluminium alloys and stainless steel, in brazed construction: radiators, oil coolers, air coolers, condensers and combined

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

Introduction to Fans. The Basics of Fan Principles and Terminology

Introduction to Fans. The Basics of Fan Principles and Terminology Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower 1.0 Closed Circuit Hybrid Cooling Tower 1.1 General: Furnish and install, as shown on the plans, factory-assembled closed circuit

More information

Domestic Pump Condensate Transfer Equipment

Domestic Pump Condensate Transfer Equipment Bulletin S-944L Domestic Pump Condensate Transfer Equipment CONDENSATE RETURN UNITS BOILER FEED UNITS LOW NPSH PUMPS VACUUM HEATING UNITS INDUSTRIAL VACUUM UNITS www.domesticpump.com Condensate Return

More information

ALZ GmbH. air cooled systems and air heaters. Competent Partners

ALZ GmbH. air cooled systems and air heaters. Competent Partners ALZ GmbH air cooled systems and air heaters Competent Partners Company overview We would like to introduce ourselves as your competent partner in heat transfer. Since 1990 the ALZ GmbH designs and manufactures

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & Blowers IN-LINE FANS ADD DIRECT DRIVE TUBEAXIAL FANS FEATURES & BENEFITS Spark resistant, cast aluminum airfoil axial impeller Aerodynamically efficient performance Factory set adjustable

More information

SECTION COOLING TOWERS

SECTION COOLING TOWERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 65 00 COOLING TOWERS SPEC WRITER NOTES: 1. DELETE BETWEEN //---// if not applicable to project. Also delete any other item or paragraph not applicable in the

More information

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans 1 - mj,, Donkin Fans Majax-2 Aerofoil Axial Flow Fans - IW '~AJAX-2 GENERAL SPF ~IFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request),

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating. SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit) 1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto

More information

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage

More information

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used in cleanrooms to

More information

Exchangers. Air-cooled Heat. Exchangers

Exchangers. Air-cooled Heat. Exchangers Hamon Process Heat Exchangers Air-cooled Heat Exchangers Hamon in a few words Hamon D Hondt factories Hamon offices and factories Hamon started its industrial activities in Europe (Belgium and France)

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING SECTION 221123 - DOMESTIC WATER PUMPS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following all-bronze and bronze-fitted centrifugal pumps for domestic cold- and hot-water circulation: 1.

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

Shell & Tube Heat Exchangers

Shell & Tube Heat Exchangers Shell & Tube Heat Exchangers Pre-Engineered Series: BCF/SSCF/SX2000/B300 PrOdUC Shell & Tube Heat Exchangers As the recognized leader in heat exchanger products, systems and technology, Standard Xchange

More information

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING TM MITTAL ENGINEERING M i t t a l E n g i n e e r i n g i s o n e o f t h e l e a d i n g m a n u f a c t u r e r s q u a l i t y e n g i n e e r i n g

More information

SECTION AIR COILS

SECTION AIR COILS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 82 16 AIR COILS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in the section

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

Air Handling Units. Danvent DV 190 and

Air Handling Units. Danvent DV 190 and Air Handling Units Danvent DV 190 and 240 www.systemair.dk arge Very large DV 190 and 240 Systemair has developed an extensive expertise within major Air Handling Units up till now usually built as individual

More information

Shell & Tube Heat Exchangers

Shell & Tube Heat Exchangers Shell & Tube Heat Exchangers Pre-Engineered Series: BCF/SSCF/SX2000/B300 PrOdUC Shell & Tube Heat Exchangers As the recognized leader in heat exchanger products, systems and technology, Standard Xchange

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

CML Northem Blower Inc. Air Movement Equipment

CML Northem Blower Inc. Air Movement Equipment CML Northem Blower Inc. Air Movement Equipment For years Northern Blower has been designing and manufacturing fan equipment for commercial and industrial applications. Product integrity and outstanding

More information

water to water heat pumps

water to water heat pumps AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically

More information

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries COMBIFAB F Fan The flexible fan for dust extraction systems in all industries Combifab F Fan Our Combifab F range of fans consists of four different fans solving all kinds of dust extraction applications

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS (630) 620-5750 Fax: (630) 629-2374 www.villageoflombard.org COMMERCIAL HOOD & DUCT SYSTEM PLAN REVIEW REQUIREMENTS International

More information

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

VMA-VMB NOVA AIR HEATERS. NoVa air heaters VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling

More information

At a Glance. Well Conceived. Cabinet Systems. IT Solutions. Enclosures. Fire Protection. Thermal Components. Ducts, Accessories

At a Glance. Well Conceived.  Cabinet Systems. IT Solutions. Enclosures. Fire Protection. Thermal Components. Ducts, Accessories Well Conceived At a Glance Cabinet Systems IT Solutions Fire Protection Ducts, Accessories Well Conceived Built exceedingly well häwa s extensive product offering The häwa group has established itself

More information

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal

More information

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features: RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source

More information

Smoke extract fan SMHA HATCH

Smoke extract fan SMHA HATCH 12.11.2012 Contents Product overview... 3 Construction... 4 Specification... 5 Selection... 6 Installation... 7 Electrical connections... 8 Dimensions and weights... 9 Product code and accessories... 10

More information

SECTION AIR COILS

SECTION AIR COILS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

POWERPLUS SPP Product Brochure

POWERPLUS SPP Product Brochure POWERPLUS SPP Brochure Available for next day delivery with ELTA SELECT Contra-Rotating Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

Product Family Overview

Product Family Overview Condensate Boiler Feed Pumps Steam Traps Valves Strainers Temperature Control Process Cooling Material Handling Size Reduction Product Family Overview Precision Engineered. Fully Integrated. Expertly Supported.

More information

Heat Transfer Equipment

Heat Transfer Equipment Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PR ODUC Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL APPLICATIONS SX2000 Pre-engineered fixed tubesheet

More information

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil. 1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled

More information

Secure hydraulic system performance. Smart solutions for cooling and cleaning hydraulic oil

Secure hydraulic system performance. Smart solutions for cooling and cleaning hydraulic oil Secure hydraulic system performance Smart solutions for cooling and cleaning hydraulic oil The products and the global support you need How can you ensure that your hydraulic systems achieve their full

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

SECTION DUCTWORK

SECTION DUCTWORK PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on

More information

Air Handling Units. Quick Guide to Danvent DV

Air Handling Units. Quick Guide to Danvent DV Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air Handling Units Quick Guide to Danvent DV Den Blå Planet, National Aquarium

More information

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information