1 6.6.3 Minimum Provision for New Systems in New Dwellings All oil fired boilers installed on or after 1 st April 2008 shall have a minimum seasonal HARP (Home-heating Appliance Register of Performance) efficiency of 86% ( and space and water heating systems should be controlled by providing the following minimum level of control: Full boiler controls, interlocks and a cylinder thermostat. The system should also be commissioned so that at completion the system and its controls are left in the intended working order and operate efficiently. Where appliance minimum HARP efficiencies on new build properties are stated in the new build specification the appliance efficiency utilised (as specified by the builder, developer, architect or consultant) is matched to this requirement. No variation to this should take place without prior consultation and agreement of the specifier. New build energy conservation includes the requirement to provide fully pumped systems with dedicated time and temperature control along with full boiler interlock and zones. New build properties are designed to comply with a Maximum Permitted Carbon Dioxide Emission Rate (MPCDER). The properties calculated Carbon Dioxide Emission Rate (CDER) must not exceed the MPCDR Minimum Provision for New/Replacement Systems in Existing Dwellings (Maximum heating zone 100m 2 ) All oil fired boilers installed on or after 1 st April 2008 shall have a minimum seasonal HARP efficiency of 86% ( and the system should be fully pumped and the space and water heating system should be controlled by providing the following: Full boiler controls, interlocks, zones and a cylinder thermostat. Independent time controls for the central heating and domestic hot water. The system should be commissioned so that on completion the system and its controls are left in the intended working order and operate efficiently Appliance Installation It is not permitted to install open flue appliances in domestic garages, therefore only room sealed balanced flue appliances should be installed in a garage location Electrical Works It is recommended that all electrical works are carried out to BS Contact Details To report a pollution incident contact the Local Authority for that area The Department of the Environment, Heritage and Local Government Edition Section 6 Page 33
2 6.7 Jersey The Jersey Building Byelaws 1997 The Planning and Building Services are responsible for the Jersey Building Byelaws. The Jersey Building Byelaws are designed to ensure that buildings are safe, healthy places in which people can live and work. The Byelaws are compiled from various Technical Guidance Documents. The list below shows the different Technical Guidance Documents available: Technical Guidance Part 1 Technical Guidance Part 2 Technical Guidance Part 3 Technical Guidance Part 4 Technical Guidance Part 5 Technical Guidance Part 6 Technical Guidance Part 7 Technical Guidance Part 8 Technical Guidance Part 9 Technical Guidance Part 10 Technical Guidance Part 11 Technical Guidance Part 12 Structure Fire Safety Combustion Appliances Site Preparation and Resistance to Moisture Ventilation Drainage, Hygiene and Water Storage Stairs, Ramps and Protective Barriers Access and Facilities for Disabled People Resistance to Transmission of Sound Glazing Conservation of Fuel and Power Electrical Safety Technical Guidance Documents can be downloaded from Work Notification Changes to the Building Regulations mean that from July 1 st 2007, Local Authority Building Control (via OFTEC, see Section 5 for OFTEC Procedures) must be notified of any oil firing storage, installation and commissioning works undertaken and self-certificated by OFTEC Registered Technicians. Furthermore, building owners must receive a certificate for any works undertaken in their home/premises, and that they comply with the Building Regulations in force on the date that the works were completed Minimum Provision for New Systems in New and Existing Dwellings: For oil fired boilers installed prior to 1st January 2011 Oil Combination Boilers Minimum SEDBUK efficiency 82% Oil (all other types of boilers) Minimum SEDBUK efficiency 85% Replacement boiler systems should be upgraded to fully pumped with full boiler controls interlock and zones (TRV s to bedrooms). Where it is not practicable to upgrade an existing system to fully pumped (Good Practice Guide 302) full boiler controls interlock and zoning is required to be added to the existing system. Page 34 Section Edition
3 For oil fired boilers installed on or after 1st January 2011 All conventional oil fired boilers shall have SEDBUK efficiency of not less than 90% as rated by SEDBUK 2005 or 88% as rated by SEDBUK 2009 and be of the condensing type. Published at All combination oil fired boilers shall have SEDBUK efficiency of not less than 86% as rated by either SEDBUK 2005 or 2009 and be of the condensing type. Published at For range cooker boilers: All oil fired range cooker boilers should have an efficiency in excess of 80% as declared at Appliance minimum SEDBUK efficiencies on new build properties form part of the SAP calculation process, it is therefore important that the appliance efficiency utilised (as specified by the builder, developer, architect or consultant) is matched to this requirement. No variation of this should take place without prior consultation and agreement of the specifier. General Systems for space and domestic hot water are required to have: Primary circuits of the fully pumped type with full boiler controls, interlock and zones. Where space heating is provided, the system should be divided into a minimum of two heating zones each with independent temperature interlock. See sub-section Thermostatic radiator valves are to be fitted on all radiators except those located in bathrooms and rooms which incorporate a room thermostat. An automatic bypass valve as required by the appliance manufacturer s installation instructions. Vented hot water cylinders complying with the heat loss and heat exchanger requirements of BS Un-vented hot water storage systems complying with BS 7206 or be certified by the British Board of Agrément or equivalent approval. Been thoroughly cleaned and flushed using an appropriate inhibitor. Water treatment provided in hard water areas. All appliances, systems and associated equipment fully commissioned in accordance with manufacturer s instructions Edition Section 6 Page 35
4 6.7.4 Minimum Provision for Replacement Systems in Existing Dwellings As defined for new systems.* * Where an individual component such as the boiler only is being replaced, thermostatic radiator valves can be omitted. However, best practice would be to fit them as part of the contract of works. Where it is impractical or uneconomical to install a condensing boiler the property may be assessed for exemption using an OFTEC CD/30 Form. Where the outcome of an assessment formally exempts the property from having a condensing boiler installed, and the replacement boiler is a regular boiler, it must have a minimum SEDBUK efficiency of 85%. If the replacement boiler is a combination boiler, it must have minimum SEDBUK efficiency of 82% Minimum Provision for New Non-Domestic Systems in New Buildings Installation on or after 1st January 2011 A minimum Effective Boiler Seasonal Efficiency as well as a minimum Boiler Seasonal Efficiency is required for oil fired boilers: Minimum Oil Boiler Seasonal Efficiency = 82% for any individual boiler Minimum Oil Boiler Seasonal Efficiency = 84% for the overall multi-boiler system Minimum Provision for Replacement Non-Domestic Systems in Existing Buildings Installation on or after 1st January 2011 This requires that a minimum Effective Boiler Seasonal Efficiency as well as a minimum Boiler Seasonal Efficiency is met. As it may not always be possible or practicable to replace a standard efficiency non-domestic appliance with a high efficiency (condensing) appliance in an existing non-domestic building it is possible to utilise additional efficiency measures (over the minimum time, temperature, demand and zoning control requirements) to achieve Heating Efficiency Credits (% points) to achieve compliance with the minimum Effective Boiler Seasonal Efficiency as follows: Minimum Effective Boiler Seasonal Efficiency (EBSE) for Oil = 86% Minimum Oil Boiler Seasonal Efficiency = 84% Therefore if a boiler with a BSE of 84% was proposed to be used a minimum of two additional percentage points of Efficiency Credits would be required to meet the minimum figure of 86%. A boiler with a Seasonal Efficiency of 84% could be installed with: Thermostatic Radiator Valves throughout = 1 Credit Weather (internal/external temperature) compensation system = 1.5 Credits Page 36 Section Edition
5 When totalled the Effective Boiler Seasonal Efficiency = = 86.5% (exceeds minimum EBSE of 86%). OR For example the 84% BSE appliance installed in conjunction with the following: Optimised Start/Stop controls = 2 Credits; would also achieve the minimum EBSE figure of 86%. For further information regarding the minimum time, temperature, demand and zoning control requirements, please refer to OFTEC Information Sheet, Approved Document L2a and L2b (England and Wales) which is available on the OFTEC website Electrical Works The Building Regulations in Jersey require that all electrical works are carried out to BS Contact Details To report a pollution incident contact the Pollution Hotline States of Jersey Government website Edition Section 6 Page 37
6 6.8 Guernsey Guernsey Approved Documents Part A Structure Part B Fire Safety Part C Site Preparation and Resistance to Moisture Part D Toxic Substances Part E Resistance to Passage of Sound Part F Ventilation Part G Health and Hygiene Standards Part H Drainage and Waste Disposal Part J Combustion Appliances and Oil Tanks Part K Safe Means of Access and Egress Part L Conservation of Fuel and Power Part M Access and Facilities for Disabled People Part N Glazing Part P Estate Roads and Service Roads Control of Building Work Regulation 6 Requirements Relating to Building Work Regulation 11 Materials and Workmanship Hazardous Waste States of Guernsey Environment Department Work Notification Changes to the Guernsey Building Regulations mean that from April 1 st 2007, Local Authority Building Control (via OFTEC, see Section 5 for OFTEC Procedures) must be notified of any oil firing storage, installation and commissioning works undertaken and selfcertificated by OFTEC Registered Technicians. Furthermore, building owners must receive a certificate of any works undertaken in their home/premises, and that they comply with the Building Regulations in force on the date the works were completed Minimum Provision for New Systems in New Dwellings Where appliance minimum SEDBUK efficiencies on new build properties are stated in the new build specification the appliance efficiency utilised (as specified by the builder, developer, architect or consultant) is matched to this requirement. No variation to this should take place without prior consultation and agreement of the specifier. New build energy conservation includes the requirement to provide fully pumped systems with dedicated time and temperature control along with full boiler interlock and zoning. Page 38 Section Edition
7 6.8.5 Minimum Provisions for New or Replacement Systems in Existing Dwellings Oil fired boilers installed on or after 5 th October 2009 shall have a SEDBUK efficiency of not less than 86% and be of the condensing type.* * This requirement does not apply: a) Where plans have been submitted in relation to the work prior to 5 th October 2009; or b) Where a boiler has been ordered or purchased and/or the contract of expected work is entered into before 5 th October 2009, provided that works are completed before 1 st January 2010 Where it is impractical or uneconomical to install a condensing boiler the property may be assessed for exemption using an OFTEC CD/30 form, a copy of which should accompany an application made to Guernsey s Environment Department using their Controlled Service Fitting Application form. Where the outcome of an assessment formally exempts the property from having a condensing boiler installed, the replacement boiler must have a SEDBUK efficiency of not less than 85% or 82% where combination boilers are specified Electrical Works It is recommended that all electrical works are carried out to BS Contact Details To report a pollution incident contact the States of Guernsey Environmental Department Guernsey Water Board States of Guernsey Government website Edition Section 6 Page 39
8 6.9 Isle of Man The Building Regulations 2007 The Department of Local Government and the Environment are responsible for the Building Regulations Building Regulations are designed to ensure the health and safety for persons in and around buildings, as well as promoting energy efficiency. The Building Regulations 2007 are compiled of various Approved Documents (known as Parts). The list below shows the different Approved Documents available: Part A Structure Part B Fire Safety Part C Site Preparation and Resistance to Moisture Part D Toxic Substances Part E Resistance to Passage of Sound Part F Ventilation Part G Hygiene Part H Drainage and Waste Disposal Part J Heat Producing Appliances Part K Stairs, Ramps and Guards Part L Conservation of Fuel and Power Part M Access and Facilities for Disabled People Part N Glazing Part P Electrical Safety Approved Documents can be downloaded from Statutory Documents Statutory Documents are the power to make law, which may be delegated by Parliament to Ministers and other persons. Statutory Instruments are the form in which delegated legislation is usually published. The Statutory Document below relates to oil fired equipment installation. SI 2007 No 153 The Building Regulations 2003 Regulation 4 Requirements Relating to Building Work Regulation 7 Materials and Workmanship Statutory Documents can be downloaded from The Department of Local Government and the Environment are also responsible for the collection and disposal of waste, which is Part F the Public Health Act Page 40 Section Edition
9 6.9.3 Work Notification Changes to the Building Regulations mean that since July 1 st 2007, Local Authority Building Control (via OFTEC, see Section 5 for OFTEC Procedures) must be notified of any oil firing storage, installation and commissioning works undertaken and self-certificated by OFTEC Registered Technicians. Furthermore, building owners must receive a certificate for any works undertaken in their home/premises, and that they comply with the Building Regulations in force on the date that the works were completed Minimum Boiler SEDBUK Efficiency (%) for New Build and Replacement Oil Fired Boilers: Oil Combination Boilers Minimum SEDBUK efficiency 82% Oil (all other types of boilers) Minimum SEDBUK efficiency 85% Appliance minimum SEDBUK efficiencies on new build properties form part of the SAP calculation process, it is therefore important that the appliance efficiency utilised (as specified by the builder, developer, architect or consultant) is matched to this requirement. No variation to this should take place without prior consultation and agreement of the specifier Oil Fired Heating Systems and Controls At present (time of print) replacement boiler systems should be upgraded to fully pumped with full boiler controls interlock and zones (TRV s to bedrooms). Where it is not practicable to upgrade an existing system to fully pumped (Good Practice Guide 302) full boiler controls interlock and zoning is required to be added to the existing system Electrical Works The Building Regulations in Isle of Man require that all electrical works are carried out to BS Contact Details To report a pollution incident contact the Department of Local Government and Environment Isle of Man Government website Edition Section 6 Page 41
10 ACKNOWLEDGEMENTS OFTEC wishes to thank all members of trade and industry who have helped in the compilation review and revision of this Technical Publication. Particular thanks also go to the following individuals for their personal contributions: Phil Chatfield David Campbell Teresa Brown Julia McDaid Ronnie Blake Phil Stanley Robert Appleyard Martyn Bridges Clive King Mark Green Charles Purkess Dean Mitchell Barrie Meridew Environment Agency Scottish Environmental Protection Agency Environment Agency Kingspan Group Blake Group Grant UK Grant UK Worcester Bosch Energy Systems Exeter Rix Petroleum, and other members of the OFTEC Registered Technicians Committee(s). Raw Consulting Tigerholm Products Meridew Consultancy (Flues & Chimney Consultant) Philip Cooper Cameron Taylor Consulting Engineers BSC.MA (Cantab) F.I. Struct E.FICE Thanks also go to the following members of OFTEC staff, without whose input this book could not have been published: Jennifer Gardner Adrian Wink Paul Rose Paul Hennon Matthew Northcott Normative References This series of technical documents contain references to both British Standards and Building Regulations/Standards applicable to regional areas of the UK and the Republic of Ireland. Copyright Alan C Black The Copyright of this publication rests in OFTEC. All rights reserved. This document and its information is supplied without liability for errors or omission and no part may be reproduced, used or disclosed except as authorised by Contract or other written permission. Page 1 Section Edition
5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...
5.5.1 General... 13 5.6 CD/30 (Oil Condensing Boiler Installation Assessment Form)... 15 5.6.1 General... 15 5.7 Technician Stationary... 18 5.7.1 CD/40 Energy Efficiency Checklist... 18 5.8 Work Notification
More informationTECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS
3.18.6 Independent Control of Two Space and One Water Heating Circulation Zones in a Fully Pumped System with Three Motorised Valves... 64 3.19 Non Domestic Systems and Processes... 64 SECTION 4 FUEL CONSERVATION
More informationCD/12 Form (Landlord Oil Installation Check)
CD/12 Form (Landlord Oil Installation Check) Diagram 47a 1 2 3 4 5 6 7 8 9 10 2010 Edition Section 7 Page 9 7.5 CD/14 (Warning & Advice Notice) 7.5.1 General This form can be used to formally notify oil
More informationOFTEC s role in promoting safe domestic oil storage
OFTEC s role in promoting safe domestic oil storage Matthew Northcott OFTEC Technical Supervisor East Land Quality Forum - 13 th November 2014 Agenda Who/What is OFTEC? Legislation Documents Domestic Oil
More informationDomestic Heating Compliance Guide
Domestic Heating Compliance Guide May 2006 1st Edition The Building Regulations 2000 As amended 2006 DOMESTIC HEATING COMPLIANCE GUIDE COMPLIANCE WITH APPROVED DOCUMENTS L1A: NEW DWELLINGS L1B: EXISTING
More information5.5 CD/14 (Warning & Advice Notice)
5.5 CD/14 (Warning & Advice Notice) 5.5.1 General This form can be used to formally notify oil users and/or persons responsible for oil-fired equipment of potential and immediate risks associated with
More informationBoiler Replacement Scheme Boiler Installer Form
Boiler Replacement Scheme Boiler Installer Form The applicant for the Boiler Replacement Scheme should ask their installer to complete this Form and return it, when completed, to the Housing Executive.
More information7.4 CD/12 (Landlord Oil Installation Safety Check)
7.4 CD/12 (Landlord Oil Installation Safety Check) 7.4.1 General This form has been devised at the request of Registered Technicians, Tenants and Property Agents and can be completed at the request of
More informationSFA Guide to Building Regulations and Solid Fuel Heating
SFA Guide to Building Regulations and Solid Fuel Heating Solid Fuel Association 95 High Street Clay Cross Chesterfield Derbyshire S45 9DZ 01773 835400 www.solidfuel.co.uk Building Regulations and Solid
More informationSpring/Summer Incentives
Spring/Summer Incentives 2018 Welcome to our latest offers Whether you are installing a new high efficiency central heating system or a single appliance, there are so many great reasons to switch to natural
More informationSpring/Summer Incentives
Spring/Summer Incentives 2018 Welcome to our latest offers Whether you are installing a new high efficiency central heating system or a single appliance, there are so many great reasons to switch to natural
More informationBuilding Regulations Update. by Eamonn Smyth
Building Regulations Update by Eamonn Smyth 9-3-2016 Part A Structure (2012) Part B - Fire Safety (201X) Part C - Site Preparation and Moisture Resistance (201X) Part D Materials & Workmanship (2013) Part
More informationTechnical Bulletin 005(B) Developed with Building Standards Scotland
Technical Bulletin 005(B) Developed with Building Standards Scotland Title: Gas cookers in internal kitchens - Ventilation requirements as applied to Scotland Date issued: 1 July 2015 Note: This version
More informationEnergy Efficiency in New Housing
Energy Efficiency Best Practice in Housing Energy Efficiency in New Housing Summary of Specifications for England, Wales and Scotland how to achieve the best in energy efficiency in new housing measures
More informationApproved. Document. Sanitation, hot water safety and water efficiency. The Building Regulations 2010
The Building Regulations 2010 Approved G1 Cold water supply G2 Water efficiency G3 Hot water supply and systems G4 Sanitary conveniences and washing facilities G5 Bathrooms G6 Kitchens and food preparation
More informationPart J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher
Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher 1 The Building Regulations The England & Wales Building Regulations are legal requirements that
More informationDOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS
DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 49, Donard Avenue BANGOR BT20 3QD Date of assessment: 08 December 2017 Date of certificate: 08 December 2017 Reference number: 9663-0022-7739-7078-8902 Type
More informationA 92 plus B C D E F 21-38
Energy Performance Certificate Northern Ireland 5 Harmin Park NEWTOWNABBEY County Antrim BT36 7UR Date of assessment: 12 August 2010 Date of certificate: 17 August 2010 Reference number: 9929-1003-0238-6360-5964
More informationRelated party disclosure: Technical Information Benchmark. 99 m² 336 kwh/m² per year 73 kg/m² per year
Energy Performance Certificate Northern Ireland 75 Mountsandel Road COLERAINE County Londonderry BT52 1JF Date of assessment: Date of certificate: Reference number: Accreditation scheme: Assessor's name:
More informationBaxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler
User s Operating Instructions Baxi System 100 HE Plus Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler Please keep these instructions safe. Should you move house, please hand them
More informationGREENSTAR CAMRAY UTILITY & UTILITY SYSTEM
GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM FLOOR STANDING OIL FIRED CONDENSING BOILER CONVENTIONAL FLUE & ROOM SEALED FLUE FOR FULLY PUMPED OPEN VENT OR SEALED CENTRAL HEATING SYSTEMS AND DOMESTIC HOT WATER
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 44, Dunlady Manor Dundonald BELFAST BT16 1YP Date of assessment: 19 September 2017 Date of certificate: 20 September 2017 Reference number: 0578-2901-0311-9093-5415
More informationDate of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number:
Energy Performance Certificate Northern Ireland 385, Oldpark Road BELFAST BT14 6QS Date of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number: 0965-2998-0821-9104-3245
More informationEnergy Performance Certificate
Energy Performance Certificate Northern Ireland 167, Killowen Grange, LISBURN, BT28 3JF Date of assessment: Date of certificate: Reference number: Type of assessment: Accreditation scheme: Assessor s name:
More informationGREENSTAR HIGHFLOW 440/550CDi
FLOOR STANDING RSF GAS-FIRED CONDENSING COMBINATION BOILER GREENSTAR HIGHFLOW 440/550CDi FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER THE APPLIANCE IS FOR USE WITH NATURAL GAS OR
More informationPower flushing and protecting your heating system can increase efficiency by at least 25%.
Thank you for considering GlowZone Sussex Ltd to install your new boiler. We believe we can offer you the best service at the right price. Please see our proposed specification, a detailed estimate is
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 37, Church Street MAGHERA BT46 5EA Date of assessment: 20 July 2011 Date of certificate: 20 July 2011 Reference number: 9639-0923-6880-4640-9926 Type of
More informationEnergy Performance Certificate
Energy Performance Certificate Northern Ireland 54, Tobarcooran Avenue, NEWTOWNABBEY, BT36 6EP Date of assessment: Date of certificate: Reference number: Type of assessment: Accreditation scheme: Assessor
More informationGreenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE
USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 25Si/30Si WALL HUNG GAS-FIRED CONDENSING COMBINATION BOILER FOR SEALED CENTRAL HEATING SYSTEMS & DOMESTIC HOT WATER THIS BOILER IS USED WITH NATURAL GAS
More informationA 92 plus B C D E 39-54
Energy Performance Certificate Northern Ireland 21 Veryan Gardens NEWTOWNABBEY County Antrim BT36 7HG Date of assessment: 23 March 2010 Date of certificate: 24 March 2010 Reference number: 9780-0327-6420-8617-9926
More informationFitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.
United Kingdom en Fitting & Commissioning Instructions Outdoor Sensor Kit EcoBlue Combi and System Range Kit Part No. 7214286 (System) Kit Part No. 7213356 (Combi) These instructions should be read in
More informationHVCA. Guide to Good Practice. Heating and Ventilating Contractors Association. Mothballing and Re-commissioning of Buildings SFG30
HVCA Heating and Ventilating Contractors Association Guide to Good Practice Mothballing and Re-commissioning of Buildings SFG30 Guide to Good Practice Mothballing and Re-commissioning of Buildings ACKNOWLEDGEMENTS
More informationOsprey 2 CFL
Osprey 2 CFL 125-150 - 180-220 Gas Fired Floor Standing Boiler Users Operating Instructions Please leave these instructions with the user Natural Gas Potterton Osprey 2 CFL 125 G.C.N o 41 590 54 Potterton
More informationNon-domestic gas installations (Edition 2)
Irish Standard I.S. 820:2010 Non-domestic gas installations (Edition 2) NSAI 2010 No copying without NSAI permission except as permitted by copyright law. I.S. xxx: Irish Standard national specification
More informationGREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32
USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXTERNAL OIL FIRED CONDENSING BOILER USING BALANCED FLUE SYSTEM GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32 FOR OPEN VENT AND SEALED CENTRAL HEATING
More informationProtect Safety Alarms
Safety Alarms Product Catalogue 2018 Protect Safety Alarms Deta s new range of interlinkable mains powered Smoke and Heat Alarms satisfy all Grade D domestic requirements as laid down by BS 5839: Part
More informationGreenstar 12i/24i System
USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 12i/24i System WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS BOILER IS USED WITH
More informationUser Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on
You can rely on User Guide and Important Warranty Information Suprima HE Range Condensing Central Heating Boiler Please keep these instructions in a safe place. If you move house, please hand them over
More informationEnergy Efficiency Standards
GENERAL INFORMATION LEAFLET 72 Energy Efficiency Standards For new and existing dwellings GENERAL INFORMATION LEAFLET 72 BEST PRACTICE PROGRAMME INTRODUCTION The Housing Energy Efficiency Best Practice
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1500: Issue 2.1 provide compartmentation in buildings This standard defines the requirements for companies installing fire resisting compartment systems approved by LPCB to
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO/IEC 17065:2012) to provide product conformity certification 4th Floor, Mill 3 Pleasley Vale Business Park Mansfield Nottinghamshire
More informationTable 1: Hot water energy requirements
Table 1: Hot water energy requirements Floor area TFA (m 2 ) (a) Hot water usage V d (litres/day) (b) Energy content of water used (kwh/year) (c) Distribution loss (kwh/year) 30 63 1146 202 40 71 1293
More informationS T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS
G R A N T C Y L I N D E R & S T O R E R A N G E High Efficiency Direct and Indirect Hot Water Storage Solutions FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS GRANT DUOWAVE
More informationDomestic heating by oil: boiler systems
Energy Efficiency Best Practice in Housing Domestic heating by oil: boiler systems Guidance for installers and specifiers Space heating flow Flow Hot water AIR Space heating return Return Cold supply Diagram
More informationGreenstar 12i system / 24i system
Greenstar 12i system / 24i system WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS APPLIANCE IS FOR USE WITH NATURAL GAS OR LPG (Cat
More informationNew Approach vs Standards and Regulation: how it all works
New Approach vs Standards and Regulation: how it all works between the EU and an EU Member State (UK example) Volodymyr Yakubov Senior Standardization Expert, INOGATE Head of International Projects, BSI
More informationIntroduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations
Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 9, Greenpark Road Rostrevor NEWRY BT34 3EY Date of assessment: 18 November 2017 Date of certificate: 19 November 2017 Reference number: 9289-3967-0219-7603-0910
More informationUser Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler
You can rely on User Guide and Important Warranty Information Promax System HE Plus A Range Condensing System Boiler Please keep these instructions in a safe place. If you move house, please hand them
More informationGrant Vortex. Boiler House Floor Standing Condensing Oil Boiler Range User Handbook. Model shown: VTXBH3646
Grant Vortex Boiler House Floor Standing Condensing Oil Boiler Range User Handbook Model shown: VTXBH3646 UK DOC 0117 Rev 1.1 November 2017 Important Note for USERs This user handbook is intended to assist
More informationStroma Certification Ltd
Stroma Certification Ltd CPD Guide: Secondary Heating This Guide has been created to tackle areas of poor knowledge relating to secondary heating. There is a question section at the end of the Guide for
More informationMAINE FUEL BOARD MASTER OR JOURNEYMAN OIL TECHNICIAN APPLICATION TO ADD AN AUTHORITY
STATE OF MAINE DEPARTMENT OF PROFESSIONAL AND FINANCIAL REGULATION OFFICE OF PROFESSIONAL AND OCCUPATIONAL REGULATION OIL BURNER MASTER / JOURNEYMAN ADD AUTHORITY APPLICANT INFORMATION (please print) FULL
More informationWhy Vaillant? Because with the new ecotec Vaillant Improves Performance.
Why Vaillant? Because with the new Vaillant Improves Performance. The result of over 139 years accumulated heating industry experience and expertise, you can rest easy knowing offers exceptionally high
More informationDOMESTIC SMOKE. working for a cleaner, quieter, healthier world
DOMESTIC SMOKE working for a cleaner, quieter, healthier world Smoke Control Areas Under the Clean Air Act 1993 local authorities can declare the whole or part of their district to be a Smoke Control Zone.
More informationConventional Electric Space Heating Systems
Running Costs of Conventional Electric Space Heating Systems Dr John Counsell Advanced Control Partnerships Limited Content s Page number Introduction 4 Running Cost 5 Estimation using SAP Different Types
More informationWater Heating UK 14 th May 2016
Water Heating UK 14 th May 2016 Hot Water Storage Systems for Heating by Solid Fuel Appliances - General Requirements and Test Methods 1.0 Introduction All hot water storage systems installed in the UK
More informationKills bills. How Vaillant technologies reduce home heating bills
Kills bills How Vaillant technologies reduce home heating bills Energy efficiency is a choice For most people, home heating and hot water systems have always been out of sight and out of mind. But now,
More informationAustralian/New Zealand Standard
AS/NZS 61779.6:2000 (Incorporating Amendment No. 1) AS/NZS 61779.6:2000 Australian/New Zealand Standard Electrical apparatus for the detection and measurement of flammable gases Part 6: Guide for the selection,
More informationInstallation and Service Manual. Heat Condensing Central Heating Boiler
United Kingdom en Installation and Service Manual Condensing Central Heating Boiler Heat 212-215 - 218-224 - 230 These instructions include the Benchmark Commissioning Checklist and should be left with
More informationir-range 8G /03.15 Changes reserved.
U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating
More informationCertification of Construction (Drainage, Heating and Plumbing) Scheme Application to become an Approved Certifier of Construction (ACC/1)
Certification of Construction (Drainage, Heating and Plumbing) Scheme Application to become an Approved Certifier of Construction (ACC/1) Please complete one form for each ACC SECTION 1: DETAILS OF APPROVED
More informationOverview EUSDSG3.11. Maintain gas fired ducted air heaters and appliances
Overview This national occupational standard is for gas engineers who are required to maintain domestic gas fired ducted air heaters and includes the following range of appliances: Down-flow, Up-flow,
More informationHealthy Homes Standards
Healthy Homes Standards Proposed healthy homes standards for heating, insulation, ventilation, moisture ingress, drainage and draught stopping DISCUSSION DOCUMENT - SUMMARY September 2018 Ministry of Business,
More informationApplication to become an Approved Certifier of Construction (ACC/1)
Application to become an Approved Certifier of Construction (ACC/1) Please complete one form for each Approved Certifier of Construction SECTION 1: DETAILS OF APPROVED CERTIFIER OF CONSTRUCTION (ACC) (If
More informationGuidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034
Guidance Note No 21/1 CE Marking Windows and doorsets to BS EN 16034 Introduction CE Marking of construction products has been a legal requirement since July 2013. It is a European requirement for all
More informationCHC's One Big Housing Conference Health and Safety Update: Gas Safety
CHC's One Big Housing Conference 2017 Health and Safety Update: Gas Safety Presented by Mark Baker CORGI Technical Services Ltd. & Association of Gas Safety Managers Legislative Documentation The Gas Safety
More informationTechnical Bulletin CE marking: from 1st July 2013
Technical Bulletin CE marking: from 1st July 2013 New regulation New obligations Same CE mark We are facing the most significant change for a decade in the way that construction products are manufactured
More informationAustralian/New Zealand Standard
AS/NZS 2918:2001 AS/NZS 2918 Australian/New Zealand Standard Domestic solid fuel burning appliances Installation Building Code of Australia Primary referenced Standard AS/NZS 2918:2001 This Joint Australian/New
More informationBaxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions
User s Operating Instructions Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move
More informationApplication to become an Approved Certifier of Construction (ACC/1)
Application to become an Approved Certifier of Construction (ACC/1) Please complete one form for each Approved Certifier of Construction SECTION 1: DETAILS OF APPROVED CERTIFIER OF CONSTRUCTION (ACC) (If
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1531: Issue 1.1 companies installing or applying passive fire protection This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for
More informationDOMESTIC & LIGHT COMMERCIAL SERVICING AND COMMISSIONING
DOMESTIC & LIGHT COMMERCIAL SERVICING AND COMMISSIONING Requirements for Oil Fired Systems Pressure Jet Appliances Foreword This publication is one of a number of technical manuals provided by OFTEC to
More informationAS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.
AS 2918 1990 Australian Standard Domestic solid fuel burning appliances Installation This Australian Standard was prepared by Committee CS/62, Solid Fuel Burning Appliances. It was approved on behalf of
More informationThe Gas Industry Unsafe Situations Procedure
The Gas Industry Unsafe Situations Procedure Fourth Edition Guidance for dealing with unsafe situations and non-compliance with current standards and procedures in domestic and non-domestic premises supplied
More informationDANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE
DANESMOOR FRONT SERVICE (FS) 12-18, 18-25 FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD Thank you for purchasing a Danesmoor Front Servicing
More informationSAP Product Characteristics Database (PCDB) - Application Guide for Compensating Boiler Controls and Time and Temperature Zone Controls (TTZC)
SAP Product Characteristics Database (PCDB) - Application Guide for Compensating Boiler Controls and Time and Temperature Zone Controls (TTZC) Background Applications can be made for entries in the SAP
More informationCombi Eco Elite Range. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi Eco Elite Range Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd
More informationBACKGROUND AND INTRODUCTION FRAMEWORK AGREEMENT FOR SELF-CONTAINED BREATHING APPARATUS, ASSOCIATED EQUIPMENT AND SERVICES REF: DS
BACKGROUND AND INTRODUCTION FRAMEWORK AGREEMENT FOR SELF-CONTAINED BREATHING APPARATUS, ASSOCIATED EQUIPMENT AND SERVICES REF: DS 072-11 CONTENTS INTRODUCTION... 1 SCOPE OF FRAMEWORK AGREEMENT... 2 PROCUREMENT
More informationPerforma 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler
0 4 You can rely on User Guide and Important Warranty Information Performa 4 Eco HE Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
More informationRecommendations texts (9.82) to be used on Energy Report in Scotland 18 July 2008
s texts (9.82) to be used on Energy Report in Scotland 18 July 2008 Note. The recommendations are picked up by software using the recommendation number (see SAP 2005 version 9.82, Appendix T). Where the
More informationBritish Gas 330 High Efficiency Condensing Boiler Manual
British Gas 330 High Efficiency Condensing Boiler Manual RD 628 Boiler pdf manual download. Boiler British Gas 330 Instructions For Use Installation And Servicing. High efficiency condensing boiler (45
More informationBuilding Energy Rating (BER)
Building Energy Rating (BER) BER for the building detailed below is: C3 Address BER Number Date of Issue Valid Until Assessor Number Assessor Company No KILBEG HEADFORD CO. GALWAY 107556003 11/05/2015
More informationONLINE VERSION ONLINE VERSION
The Building Regulations 2000 Combustion appliances and fuel storage systems APPROVED DOCUMENT J J1 Air supply J2 Discharge of products of combustion J2A Warning of release of carbon monoxide J3 Protection
More informationGREENSTAR HIGHFLOW 440/550CDi
FLOOR STANDING RSF GAS-FIRED CONDENSING COMBINATION BOILER GREENSTAR HIGHFLOW 440/550CDi FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER THE APPLIANCE IS FOR USE WITH NATURAL GAS OR
More informationSOUTH CAMBRIDGESHIRE DISTRICT COUNCIL. Planning and New Communities Director
SOUTH CAMBRIDGESHIRE DISTRICT COUNCIL REPORT TO: Planning Committee 9 January 2013 AUTHOR/S: Planning and New Communities Director S/2270/12/FL FEN DRAYTON 850m long flood defence embankment ranging in
More informationUser Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.
User Guide and Important Warranty Information Suprima 30-80 HE Condensing Central Heating Boiler Please read this document and keep it safe. It will help you out should your boiler need attention. Introduction
More informationACCREDITATIONS. MEMBERSHIPS & AWARDS. Quality counts, don t settle for anything less... BSI Kitemark for energy rated windows
Quality counts, don t settle for anything less... 01:2007 Quality Management System for Manufacture & Installation AS 2030 : 2012 Environmental Management System for the Manufacture & Installation of windows,
More informationBuilding Regulations 2010: What it means to you.
Building Regulations 2010: What it means to you. Where are we going? Ongoing changes to the ADF (Approved Document F) will bring about several differences to the way in which we use Ventilation in both
More informationGreenstar 24i junior / 28i junior
Greenstar 24i junior / 28i junior WALL HUNG GAS-FIRED CONDENSING COMBINATION BOILER FOR SEALED CENTRAL HEATING SYSTEMS & DOMESTIC HOT WATER THIS APPLIANCE IS FOR USE WITH NATURAL GAS OR LPG (Cat II 2H3P
More information10 Bridge Gardens Barnsley 85,000
A traditional bay fronted semi detached house which has undergone modernisation and refurbishment and is situated within walking distance of Barnsley Town Centre. Accommodation comprises entrance lobby
More informationheat interface units A BOILER WITHOUT A FLAME
A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.
More informationNew Zealand Sales Hotline: Sales Fax:
Robert Bosch (Australia) Pty Ltd Melbourne 1555 Centre Road Clayton Victoria 3168 P (03) 9541 5555 F (03) 9541 5595 Sales Hotline: 1300 30 70 37 Sales Fax: 1300 30 70 38 www.bosch-climate.com.au New Zealand
More informationA basic guide to BS 8418:2015 CCTV Systems for Installers
A basic guide to BS 8418:2015 CCTV Systems for Installers April 2017 For other information please contact: British Security Industry Association t: 0845 389 3889 e: info@bsia.co.uk www.bsia.co.uk Form
More informationSEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY
the complete range of oil and gas fired condensing boilers Warmflow Boilers warmflow - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we have
More informationMoor Heating Air Source Heat Pump Case Study
Moor Heating Air Source Heat Pump Case Study This case study is based on an air source heat pump installed by Solarwall for Annette Hudpseth and Neil Bye. They live in a four bedroom maisonette above a
More informationUser s Operation Instructions & Important Warranty Information
United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Plus 18s - 24s - 30s 24c - 28c - 35c - 39c Please keep these instructions
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Certsure LLP trading as NICEIC or ELECSA ISO/IEC 17065:2012 to provide product conformity certification Warwick House Houghton Hall Park Houghton
More informationSummary of changes between PD 6662:2010 and PD 6662:2017 a guide
Summary of changes between PD 6662:2010 and PD 6662:2017 a guide October 2017 For other information please contact: British Security Industry Association t: 01905 342 020 e: info@bsia.co.uk www.bsia.co.uk
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-26992-0 SOUTH AFRICAN NATIONAL STANDARD Fire detection and alarm systems for buildings System design, installation and servicing Published by SABS Standards Division 1 Dr Lategan Road Groenkloof
More information