Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Size: px
Start display at page:

Download "Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks"

Transcription

1 Ventilation Heat Recovery PoolPak International Maintaining Your Climate for Indoor Pools and Waterparks Complete Ventilation, Heat Recovery and Dehumidification Packaged System by PoolPak International P o o l P a k I n t e r n a t i o n a l

2 Bringing the Outside In Today s pools have evolved into something greater than just a place for casual recreation. The advent of waterparks, filled with water features such as slides, dump buckets, and lazy rivers, entertain swimmers year round. But unlike facilities in warmer, tropical climates, pool owners in less temperate regions need to enclose their waterparks to extend their shorter summer season. Indoor pools have unique HVAC challenges not present in standard building construction. The facility is constantly subjected to evaporation and condensation cycles of corrosive pool water effecting occupant comfort and structural integrity of the facility. Ventilation standards require high amounts of outside delivered to the space for health concerns, and the space temperature and humidity must be maintained for an enjoyable experience. 2

3 The traditional approach to indoor pool space and air management utilizes both mechanical dehumidification and ventilation to maintain precise setpoint conditions. However, newer and more sophisticated control system technology is now able to better utilize outside air for dehumidification without dramatically sacrificing occupant comfort, offsetting the need for mechanical dehumidification. Open Versus Enclosed Facility Enclosed waterpark facilities like their open-air counterparts have the same objective of providing acceptable year-round conditions to maximize facility use. Open waterparks in warmer climates rely on natural conditions to provide a favorable environment most of the year. The higher summertime temperatures and humidity remain acceptable while the swimmers are active and wet. On occasional colder days, the pool is usually left for only the brave at heart. In geographic areas having shorter summer seasons, waterpark facilities must be enclosed for use year round. These facilities may use natural ventilation assisted by mechanical ventilation to minimize temperature and humidity during hotter summer months. 3

4 The New ClimatePak - Dehumidification Through Ventilation There are several proven approaches to indoor pool dehumidification with 100% ventilation being an economical method for large waterpark facilities. PoolPak International is introducing the ClimatePak, another proven approach to solving indoor air quality problems in waterparks and large natatoriums. The ClimatePak differs from traditional dehumidification systems by utilizing outside air to remove moisture rather than mechanical refrigeration. It takes advantage of the naturally dry outdoor air to control humidity and ventilate the facility while reducing the cost of operation. Integrated Packaged Solution The ClimatePak is not simply an air handler but a packaged solution designed specifically to manage indoor pool air quality. Everything about the unit is engineered to work in concert, eliminating the guesswork associated with management of your indoor poolroom environment. The Proven Approach is Your Best Assurance Total Satisfaction The PoolPak Proven Approach is the culmination of 25 years of solid experience in indoor pool dehumidification. The entire PoolPak dehumidification product line is designed specifically for one reason and one reason only to provide you with the best, long-lasting solution for your facility. Designed Specifically for the Corrosive Pool Environment Unlike standard air handlers and conventional dehumidification equipment designed for the commercial market, the ClimatePak is built to the same corrosion-resistant standards found in the other PoolPak product lines. Properly applied and maintained PoolPak equipment lasts longer for a better return on your investment. Energy-Efficient Operation ClimatePak utilizes a passive corrosion resistant heat pipe and bypass damper heat recovery system that recovers up to 60% of the waste heat from the exhaust air. Integrated control technology precisely manages internal conditions for maximum benefit at the lowest operating cost. Maximizing Performance with Proven Approach Control Technology A fully integrated packaged microprocessor based control system complete with application-specific software and processgrade sensors measures airflow, temperature and humidity and controls the key components. Standard PoolPak features such as variable frequency drives and efficient air foil fans offer superior performance. Lower Maintenance Reduces Downtime The ClimatePak design utilizes dry outside air in place of compressors. This eliminates the need for periodic refrigeration maintenance of a refrigeration system. Standard PoolPak features such as major electrical components being out of the air stream provide access to critical components for fast routine service. 4

5 Extending the Season All geographic locations experience higher temperature and humidity conditions during peak summer periods, but the length of these periods will be dramatically different between, for example, Florida and Maine. An enclosed indoor pool facility will maintain open air conditions with little effect on usability during these short hot and humid periods while maintaining comfortable conditions the balance of the year. During colder months, both the pool water and space temperature must be heated to comfortable levels. The heated pool water, warm air and water agitation escalates the evaporation rate filling the space to an uncomfortably high humidity level. To control these humidity levels, dryer outside air can be introduced to the space, lowering humidity to a more comfortable level. Auxiliary heating is used to temper the supply air and maintain a comfortable temperature as the building conditions require. ClimatePak controls the complex relationship between temperature and humidity, maintaining comfortable space conditions. Controlling Indoor Humidity with Outside Air To control indoor humidity, minimum amounts of drier outside air are metered through the ClimatePak to maintain an acceptable comfort band. As outdoor humidity increases, the amount of outside air through the ClimatePak increases to offset the humidity within the facility. Dilution of the indoor air is further supplemented using auxiliary exhaust fans and/or windows for natural ventilation as required. LESS Outside Air is Drier than Needed Dehumidification Using Outdoor Air Reduced OA Quantity Increased OA Quantity Outside Air Provides Acceptable Range of Dehumidification OUTDOOR HUMIDITY LEVELS Dehumidification Using ClimatePak Natural Ventilation Additional Fans Outside Air too Humid for Dehumidification MORE Maximum Acceptable Space Conditions Maximum Desired Space Humidity Minimum Desired Space Humidity MORE INDOOR HUMIDITY LEVELS LESS Controlling Indoor Temperature with Outside Air During a majority of the year, dry outside air is metered into the facility to control humidity, tempered with a heat recovery system along with auxiliary heating to maintain an acceptable space temperature. When the indoor temperature increases beyond maximum desired temperature, natural ventilation is used to supplement temperature reduction. An optional cooling coil can be introduced to reduce space temperature and extend the range of acceptable space temperature. Less Heating Required Optional Cooling Range Extended with Heat Recovery LESS Exhaust Air Heat Recovery OUTDOOR TEMPERATURE LEVELS Range Extended by Auxiliary Cooling Auxiliary Cooling With ClimatePak Using Outside Air Only MORE Maximum Acceptable Space Conditions Maximum Desired Space Temperature Minimum Desired Space Temperature MORE INDOOR TEMPERATURE LEVELS LESS 5

6 Modes of Operation Dehumidification Mode SITUATION Outside air is cooler than the interior space and dry enough to provide proper dehumidification with auxiliary heating as required. CLIMATEPAK ACTIONS 1. Poolroom air is returned to the unit where some (or all) is exhausted as dictated by the conditions. 2. Exhaust air is blown through the heat recovery coil /damper system, capturing a significant portion of the exhaust air heat. 3. Dry, cold outside air and facility exhaust air conditions are continuously sampled by the control system, determining the exact amount of outside air to be introduced. 4. Outside and exhaust air are drawn through the passive heat recovery coil damper system to precondition make-up outside air. 5. ClimatePak reduces outside air until it reaches a minimum quantity as prescribed in ASHRAE Standard Conditioned outside air is mixed with the facility return air before it is filtered and heated to the proper air temperature and supplied to the space. Dehumidification with Auxiliary Cooling Mode SITUATION Outside air is warmer than the interior space but is dry enough to provide partial dehumidification. CLIMATEPAK ACTIONS 1. Air from the poolroom is returned to the unit where part of it is exhausted. 2. A significant portion of the exhaust air stream is blown through the heat recovery coil / damper system with no heat transferred to the outside air stream. 3. The outside air is warmer than desired and so an auxiliary cooling coil can be provided to temper the supply air to a lower air temperature while provided some dehumidification. 4. The supply air is then distributed through the facility ductwork. 6

7 Ventilation (Summer) Mode SITUATION The outside air supplied through the ClimatePak is warmer and more humid than the interior space and cannot provide dehumidification or cooling at the current airflow. CLIMATEPAK ACTIONS 1. Air from the poolroom is returned to the unit where 100% is exhausted. 2. The exhaust air stream is blown through the heat recovery coil / damper system with no heat transferred to the outside air stream. 3. The supply draws and filters 100% outside air for distribution through the facility. 4. Natural ventilation through operable skylights, doors, windows and external exhaust fans augments the air supplied and exhaust by the ClimatePak providing a supplementary dehumidification and space temperature control. Unoccupied Mode SITUATION When dehumidification requirements are lower in the space, the fan speed can be reduced to conserve electrical energy. CLIMATEPAK ACTIONS 1. The control system is instructed to switch to Energy Saver Mode during unoccupied periods or in situations where design conditions have been satisfied, and there is an opportunity to reduce supply air flow. 2. With the exception of reduced air flow, the ClimatePak operates in the standard dehumidification mode. 7

8 ClimatePak Features & System Details Heat Recovery System Corrosion resistant passive heat pipe Corrosion resistant bypass damper system Environmentally friendly R410a refrigerant Cold surface sensor system Air Flow Measuring Station Process-quality sensor Accurate control of air flows ECC Control System Integrated for seamless operation VFD for accurate air management Isolated Major Components Out of corrosion air stream Ease of maintenance Plenum Air Foil Exhaust Fan High efficiency Low noise EPAK TEFC motor 8

9 Heating Coil Coated for corrosion resistance Includes control valves and sensors Hot water or steam Auxiliary Cooling Coil (optional) Coated for corrosion resistance Chilled water or glycol for tight temperature control Housed Air Foil Supply Fan High efficiency Low noise EPAK TEFC motor Air Flow Measuring Station Process-quality sensor Accurate control of air flows Corrosion-Resistant Double Wall Panel System 2 injected foam insulation High quality door hardware Corrosion resistant Aluminum Modular Frame Extruded structural system for rigidity Anodized aluminum for corrosion resistance Split design for easy shipping Aluminum Diamond Plate Floor Slip resistant Corrosion resistant 9

10 System Integration As in other PoolPak products, the ClimatePak is a complete packaged dehumidifier with integrated mechanical and control systems. You can be assured efficient operation from day one with no hassles. Hardware The ECC controller, process grade sensors and actuators offer reliable control and monitoring of the mechanical components. Corrosion resistant and time tested components are PoolPak standard features. Variable Frequency Drives Air Measuring Systems Process-Grade Temperature and Humidity Sensors Process-Grade Actuators Building Automation Systems (BAS) Software Expert control and measuring functions are assured and supported to assure peak operating performance. To get the greatest benefit from the outside air, the ClimatePak constantly measures and compares conditions as required for optimum surroundings. Building Automation Systems (BAS) Remote Modbus and Lonworks packages are available for integration with building automation systems. This feature offers information as well as user adjustable setpoints for the facility operators. 10

11 ClimatePak Technical Data Summary of ClimatePak VHR Units Average OA Dew Point Temp (F) Model Moisture Removal Capacity (Lbs/Hr) Maximum Outside Air (cfm) Maximum Supply Air (cfm) 60 VHR VHR VHR VHR VHR VHR Note: Based on space condition of 84F, 60% RH Contact the factory for all sizing, specifying, and pricing support. ( , 11

12 Other High-Performance Products Using the PoolPak International Proven Approach for Indoor Pool Dehumidification PoolPak SWHP Series For Large Pools and Natatoriums PoolComPak AW Series For Hospitality and Residential Pools RoofPak Series For Commercial and Hospitality Pools The Leader in Indoor Pool Dehumidification 3491 Industrial Drive. York, PA USA Fax for more information: M41MK-VHRBRO0114

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS PoolPak MPK Series Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS PoolPak.com The PoolPak MPK Series Built using the PoolPak Proven Approach SM, the MPK Series

More information

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units FORM 100.50-EG2 (502) TM FlexSys Configured Packaged Rooftop Air Conditioning Units TABLE OF CONTENTS PAGE TOTAL INTEGRATED HVAC SYSTEM... 3 AN INTEGRATED SOLUTION... 4 INTRODUCTION... 6 System Description...

More information

POOLPAK R-410A SWHP SERIES

POOLPAK R-410A SWHP SERIES POOLPAK R-410A SWHP SERIES (MODELS SR, S, SE, SEP) Engineering Guide Packaged Natatorium Environment Control System PoolPak TM SWHP Series Natatorium Dehumidification Unit For unit weights and dimensions,

More information

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection NC NC Series NG NG Series Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection NC NC SERIES PERFORMANCE DATA Model Capacity Min. Circuit Ampacity (MCA)

More information

Innovent s. Custom Pool Dehumidification Units. Your best choice for swimmers, spectators and savvy building owners.

Innovent s. Custom Pool Dehumidification Units. Your best choice for swimmers, spectators and savvy building owners. Innovent s Custom Pool Dehumidification Units Your best choice for swimmers, spectators and savvy building owners. Would you like to provide a clean and healthy environment for your indoor pool while reducing

More information

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Packaged Heat Recovery Systems Micro-Z

More information

POOLPAK R410A MPK SERIES

POOLPAK R410A MPK SERIES POOLPAK R410A MPK SERIES MS (Supply Fan and Outside Air) MSE (Supply Fan, Exhaust Fan, and Outside Air) MSEP (Supply Fan, Exhaust Fan, Purge Fan, and Outside Air) Engineering Guide Packaged Natatorium

More information

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information

Dehumidifying with Dedicated Outdoor Air

Dehumidifying with Dedicated Outdoor Air Dehumidifying with Dedicated Outdoor Air System Configurations Figure 71. Configurations for dedicated outdoor-air systems A dedicated outdoor-air handler separately filters, cools, dehumidifies, heats,

More information

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)

More information

POOLPAK R-410A MPK SERIES

POOLPAK R-410A MPK SERIES POOLPAK R-410A MPK SERIES MS (Supply Fan and Outside Air) MSE (Supply Fan, Exhaust Fan, and Outside Air) MSEP (Supply Fan, Exhaust Fan, Purge Fan, and Outside Air) Installation, Operation, Maintenance

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum

More information

Installation, Operation and Maintenance

Installation, Operation and Maintenance Installation, Operation and Maintenance ClimatePak VHR FORM #: SVW04-VHRIOM-20160816 SUPERCEDES: MK4-IOMVHR REV UPDATED: AUGUST 16, 2016 2016 PoolPak International. All rights reserved. TABLE OF CONTENTS

More information

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM D Units Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM INDUSTRY-LEADING HVAC MANUFACTURER Nortek Air Solutions is the largest custom HVAC manufacturer in North America, with a combined total of

More information

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features: RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

Seresco Indoor Pool Dehumidifiers. Unrivaled Performance, Reliability and Value

Seresco Indoor Pool Dehumidifiers. Unrivaled Performance, Reliability and Value Seresco Indoor Pool Dehumidifiers Unrivaled Performance, Reliability and Value COLLEGE AQUATIC CENTER HOTELS Dehumidification is Serious Business Natatorium environment control is a complex business with

More information

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M Bring the fresh in. D E D I C AT E D O U T S I D E A I R S Y S T E M Breathe easier. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting

More information

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks DEHUMIDIFICATION: Ice Arena Application & Product Guide Design, construct and operate to control indoor humidity in ice rinks Munters is the world leader in dehumidification Munters is the largest manufacturer

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features: RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source

More information

100% Outdoor Air Dehumidification Methods

100% Outdoor Air Dehumidification Methods Technical Bulletin 16 100% Outdoor Air ehumidification Methods I NTROUCTION As consulting engineers and end users implement the ASHRAE 6 ventilation code, they are faced with selecting an appropriate method

More information

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information

Installation, Operation and Maintenance

Installation, Operation and Maintenance Installation, Operation and Maintenance PoolPak SWHP FORM #: SVW05-SWHPIOM-20171107 SUPERCEDES: MK5-IOMSWHP REV UPDATED: NOVEMBER 2017 2017 PoolPak LLC. All rights reserved. TABLE OF CONTENTS IMPORTANT...

More information

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements Custom Performance Climate Changer air handlers Expertly designed and built to meet your specific requirements Experience and expertise to meet any custom air-handling requirement Trane Performance Climate

More information

Designing Energy Efficient Outdoor Air Systems

Designing Energy Efficient Outdoor Air Systems Designing Energy Efficient Outdoor Air Systems Joseph Thorndal Applied Products Sales Manager Greenheck, Schofield, Wisconsin 1 Joseph Thorndal BS Industrial Engineering North Dakota State University Work

More information

THE ULTIMATE ROOFTOP SOLUTION

THE ULTIMATE ROOFTOP SOLUTION Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly

More information

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Heat Pumps SA SERIES Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum and reduced maintenance Double wall rigid polyurethane foam injected panel

More information

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

terminal units only provide sensible cooling, a separate dehumidification system is usually needed. providing insights for today s hvac system designer Engineers Newsletter volume 44 3 Dual-Temperature Chiller Plants This Engineers Newsletter describes several dual-temperature configurations that can

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ Economical, Flexible, Advanced Performance Ventilation and Dehumidification for Healthy IAQ CompleVent the Energy Conserving, Cost-Efficient Way to Meet ASHRAE Standards Today s focus on indoor air quality

More information

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features: Heat Pumps SB SERIES SB Series Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features: Vertical self-contained units with capacities from 3-18 tons ECM driven direct drive backward curved

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects VariCool VAV (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water Unique Solutions for All-Indoor HVAC Projects Water Source Heat Pump Water-Cooled Chilled Water Modular

More information

Benefits Offered by Passive Dehumidification Wheel Speed Control

Benefits Offered by Passive Dehumidification Wheel Speed Control Benefits Offered by Passive Dehumidification Wheel Speed Control White paper By John Fischer Benefits Offered by Passive Dehumidification Wheel Speed Control The most significant advantage of the Pinnacle

More information

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems Volume 6, Issue 1 CARRIER edesign SUITE NEWS Modeling 100% OA Constant Volume Air Systems This article provides an overview of how to model a stand-alone constant air volume (CAV) 100% OA system in HAP.

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1

More information

b.) Technical Information:

b.) Technical Information: Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section

More information

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Heat Pumps M2 SERIES Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Water-source and geothermal heat pump self-contained units with capacities from 3-70 tons 10%-100% variable

More information

Energy Recovery Ventilation

Energy Recovery Ventilation Published on Business Energy Advisor (https://oncor.bizenergyadvisor.com) Home > Energy Recovery Ventilation Energy Recovery Ventilation Proper ventilation is essential for maintaining good indoor-air

More information

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features: Heat Pumps SB SERIES Features: Vertical self-contained units with capacities from 3-18 tons ECM driven direct drive backward curved plenum supply fans for improved energy Double wall rigid polyurethane

More information

Moisture, Ventilation & Global Weirding NEHERS Webinar Series

Moisture, Ventilation & Global Weirding NEHERS Webinar Series Moisture, Ventilation & Global Weirding NEHERS Webinar Series Douglas McCleery, PE, CEM July 10, 2017 Discussion Points Weather and Building Practices Constant Change Warm Weather o Temperature o Humidity

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

Product Release Summary

Product Release Summary Product Release Summary 48/50HC with System March 2012 TC Benefits of EnergyX System Why Energy Recovery 1. Code requirements: ASHRAE 90.1-2004: Energy Recovery is required when design supply air capacity

More information

Cultivator & Hybrid Cultivator

Cultivator & Hybrid Cultivator Cultivator & Hybrid Cultivator Precision Temperature & Humidity Packaged Unit INTRODUCTION The Cultivator Series package unit is the industry s MOST ENERGY EFFICIENT and HIGHEST capacity dehumidifier on

More information

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons Your Chiller Solution For Efficiency And Reliability McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons McQuay Dual Compressor Centrifugal Chillers Superior part load efficiency, reliability

More information

Relative Humidity in Schools Jim Cummings and Chuck Withers

Relative Humidity in Schools Jim Cummings and Chuck Withers to Co n tr o l Relative Humidity in Schools Jim Cummings and Chuck Withers SEEC Southern Energy-Efficiency Center Energy Efficient Strategies to Control Relative Humidity in Schools James Cummings and

More information

AFD Industrial Dehumidifier Series

AFD Industrial Dehumidifier Series Dryomatic HUMIDITY CONTROL A MEMBER OF MARDUK HOLDING COMPANY LLC AFD Industrial Dehumidifier Series DRYOMATIC is a Leader in the Dehumidification Industry with Over 5 Years Experience and Thousands of

More information

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR KITCHENS HOTEL CORRIDORS LABORATORIES CONFERENCE CENTERS SCHOOLS PAINT BOOTHS MALLS/SHOPPING CENTERS DOAS UNITS Capacities 5-30 Tons 50-800 MBH 30-120 kw 650-9,000

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 3.8.2 Mechanical Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Rudy's Star Motors Construction Site:

More information

Natatorium Economizer Vs. Conventional Dehumidifier

Natatorium Economizer Vs. Conventional Dehumidifier Technical Bulletin 18 Natatorium s. Conventional Dehumidifier I NTODCTION This technical bulletin will review how an economizer-type indoor pool dehumidifier functions, and provide details on its control

More information

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC VOLUME ONE NUMBER THREE SYNOPSIS A N H V A C N E W S L E T T E R F O R B U I L D I N G O W N E R S A N D M A N A G E R S In this issue... Part-Load Strategies Why they re important.......... 1 What Things

More information

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable

More information

NATATORIUM DESIGNMANUAL

NATATORIUM DESIGNMANUAL NATATORIUM DESIGNMANUAL For more information visit SerescoDehumidifiers.com/DesignGuide Copyright 2013 Seresco Technologies Inc. All rights reserved About the Author Ralph Kittler, P. Eng. The creation

More information

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active. TRACE 700 incorporates two chilled beam strategies: passive and active. Passive chilled beams consist of a fin-and-tube cooling coil, contained in a housing (or casing), suspended from the ceiling. Chilled

More information

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001 This HAP e-help provides a high-level overview of induction beams, how they work and how to model them in HAP 4.8 (and later versions). The first half of the article explains how induction beams work.

More information

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1: 4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This

More information

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings INTRODUCTION TO: ASHRAE STANDARD 90.1, 2013 HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings Rocky Mountain ASHRAE Technical Conference, April 29, 2016 SEAN BEILMAN, P.E.,

More information

Vision and Skyline Semi-custom Air Handlers

Vision and Skyline Semi-custom Air Handlers Vision and Skyline Semi-custom Air Handlers Flexible design solutions to match building applications Skyline Outdoor Air Handler 900 to 65,000 cfm Vision Indoor Air Handler 900 to 100,000 cfm Custom solutions

More information

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort

More information

Trane CDQ Desiccant Dehumidification

Trane CDQ Desiccant Dehumidification Engineering Bulletin Trane CDQ Desiccant Dehumidification September 2004 CLCH-PRB020-EN Preface This engineering bulletin presents the Trane CDQ desiccant dehumidification system. It explains the features

More information

Trailblazer air cooled scroll chillers

Trailblazer air cooled scroll chillers Trailblazer air cooled scroll chillers Changing the way you think about air cooled chillers 30 to 240 tons with Variable Speed Condenser Fan Technology People and ideas you can trust. Changing the way

More information

Trane Family of Terminal Products

Trane Family of Terminal Products Trane Family of Terminal Products It s time to take another look at terminal. As your partner, Trane understands it takes more than a concept to design an effective HVAC system. Between cost and code compliance

More information

RT-OA TM Rooftop Outdoor-Air (DOAS)

RT-OA TM Rooftop Outdoor-Air (DOAS) RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels, Retail Stores...!

More information

Indoor Pool Design Considerations Colorado Springs, Colorado

Indoor Pool Design Considerations Colorado Springs, Colorado Indoor Pool Design Considerations Colorado Springs, Colorado September 20, 2018 Presentation by Eric S. Johnson, P.E. LifeMember, ASHRAE, Austin Chapter DESIGN CONSIDERATIONS HUMIDITY CONTROL FOR INDOOR

More information

High-Performance VAV Systems

High-Performance VAV Systems This article was published in ASHRAE Journal, October 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not

More information

Installation, Operation and Maintenance

Installation, Operation and Maintenance Installation, Operation and Maintenance ComPak R-410A AW/HCD Series RoofComPak Series HCD (High Capacity Dehumidifier) AW (Air and Water) Horizontal (H) and Vertical (V) Configurations FORM #: SVW06-PCPIOM-20170808

More information

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Trane Performance Climate Changer Air Handlers. An air handler for every need. Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: designed to optimize your HVAC system. Trane Performance Climate Changer air

More information

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY SUPERIOR IAQ LOW FIRST COST BEST ROI ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY Pinnacle manages 100% of a building s ventilation and indoor humidity load in a single package. Chilled beams have

More information

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1: 4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This

More information

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT ENERGY EFFICIENT AIR COMFORT EP SERIES PACKAGED ENERGY RECOVERY SYSTEM Certified total energy recovery performance (sensible and latent) up to 90% efficient. Double-wall panel construction eliminates exposed

More information

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane.

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane. T-Series Climate Changer Air Handler TM It s Hard To Stop A Trane. T-Series Climate Changer Air Handler The Trane tradition of excellence continues with the T-Series Climate Changer air handler. Using

More information

Energy Recovery with Cooling and Heating

Energy Recovery with Cooling and Heating Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model

More information

Maverick II Commercial Rooftop Systems 15 to 75 tons

Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems System performance and reliability make Maverick II commercial packaged rooftop systems the ideal solution for

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes In Humid Climates BY DAVID A. JOHN, P.E., MEMBER ASHRAE; DREW ELSBERRY, MEMBER ASHRAE Designing g a building s HVAC system requires designers

More information

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Trane Performance Climate Changer Air Handlers. An air handler for every need. Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: The most comprehensive air-handler portfolio in the industry. The portfolio

More information

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE This article was published in ASHRAE Journal, March 20145 Copyright 2015 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission

More information

HVAC Mandatory Provisions Part II, Page 1

HVAC Mandatory Provisions Part II, Page 1 HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency

More information

NE Series TM. Indoor Pool Dehumidifiers The industry benchmark in quality and customer satisfaction

NE Series TM. Indoor Pool Dehumidifiers The industry benchmark in quality and customer satisfaction NE Series TM Indoor Pool Dehumidifiers The industry benchmark in quality and customer satisfaction standard components hotel residential spa/whirlpool competition swim insitutional school/university fitness

More information

Variable Refrigerant Flow (VRF) Systems

Variable Refrigerant Flow (VRF) Systems Variable Refrigerant Flow (VRF) Systems Flexible Solutions for Comfort Carrier Corporation Syracuse, New York January 2013 TABLE OF CONTENTS INTRODUCTION... 2 VRF TECHNOLOGY... 2 ADVANTAGES OF A VRF SYSTEM...

More information

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop Energy-Savings Strategies for Rooftop VAV Systems Occupied set-point temperature Unoccupied set-point temperature Rooftop variable-air-volume (VAV) s are used to provide comfort in a wide range of building

More information

Desiccant Dehumidifier

Desiccant Dehumidifier Since the 1950s Desiccant Dehumidifier Dry Spaces With NO Added Heat BMIL Technologies, LLC 4915 Arendell St., #313 Morehead City, NC 28557 PH 252-727-0994 FAX 252-727-0996 WWW.BMIL.COM Product Description

More information

Natatorium Design Guide

Natatorium Design Guide Natatorium Design Guide Table of Contents Introduction............................... 3 Comfort, Health and Safety.................. 4 Comfort and Health....................... 4 Humidity Control Calculations...............

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Ventilation in Humid Climates: Data from Field Experiments

Ventilation in Humid Climates: Data from Field Experiments Gaylord Texan Resort & Convention Center October 20-23, 2004 - Dallas, Texas Ventilation in Humid Climates: Data from Field Experiments Neil Moyer FSEC Yearly Housing Starts Past 3 Years Source: NAHB x

More information

Armstrong Cool-Fog Systems

Armstrong Cool-Fog Systems Armstrong Cool-Fog Systems Armstrong International, Inc. is a leading supplier of hydropneumatic fogging systems used for both humidification and evaporative cooling. Its systems were first developed in

More information

C-Series. Unique Solutions for All-Indoor HVAC Projects

C-Series. Unique Solutions for All-Indoor HVAC Projects C-Series 1 to 15 tons Horizontal Self-Contained or Split Systems Water-Cooled, Chilled Water, Water Source Heat Pump or MagnaCool Precision Cooling Package Unique Solutions for All-Indoor HVAC Projects

More information

POOLPAK R-410A MPK SERIES

POOLPAK R-410A MPK SERIES POOLPAK R-410A MPK SERIES MPK D - CABINET Model MS, Int. ACC, Int. Elec. Heat GENERIC DWINGS EGW07-DS00IACELE-20150217 Packaged Natatorium Environment Control System PENDING PoolPak MPK Series Natatorium

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features: CB/CF CONDENSERS AND CONDENSING UNITS CF CB Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity

More information

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize

More information

Redesign of Bennett Hall HVAC System

Redesign of Bennett Hall HVAC System MEE 488 April 18, 2006 Redesign of Bennett Hall HVAC System Greg Andreasen Michael Chicoine Florent Hohxa Jason Jacobe Mechanical Engineering, University of Maine, Orono ME 04473, USA ABSTRACT Our task

More information