1 Using the Lely Robot Sampler 4
2 Lely Check List First time start-up settings done? Is sampler level? Is milk line connected through sampling valve? Is air pressure to the shuttle correct? Are there enough bottles in the rack? Is spoon set in Position 1? If there is more than 1 robot, and are the racks numbered accordingly (i.e. 1, 2, 3, 4)? Is the rack type correct (i.e. 60 bottle)? Is the robot off Pause mode? After the first sample is taken, is there the proper amount of milk in the bottle? If none of the above resolves sampling problem, please call your Robot Specialist. 5
3 A dealer should always inspect the valve mechanics prior to the first test to ensure they are working properly. Lely uses a 60 bottle shuttle (sampler) that is connected via a small milk and air hose. The air hose provides for a mechanical action that moves the sampling spoon from bottle to bottle. It starts at bottle 1 in the lower left, moves up to the end, rounds the corner, and comes back down weaving through all rows in an S formation. When a cow completes her milking, air is injected into the weigh jar bubbling the milk then draining to the 5 kg mark. The milk is controlled by a valve and is released by gravity through a hose into the spoon above the next empty bottle. About 25 seconds (a good starting point) is required to ensure enough milk gets through the hose to the spoon for a two-thirds bottle level. Factors such as floor height, hose length, pinched hoses, and debris in the hose, all affect sample volume. Look for the number 1 marked on the top of the sampler to make sure you have it placed in the shuttle properly. Preparing & Hooking up the Sampler Order specific robot bottles with removable lids from the lab (bottles have bar code on side) Remove lid ensuring pill remains in bottle as you place them in the rack Place sampler next to the robot. Do not place it in the path of the robot arm or water spray Level sampler by adjusting individual legs 6
4 Testing the Sampler Movement Enough air? When a robot is installed, the air valve is typically closed by default. Make sure the air valve is about 80% open. 1 Insert Air Valve 2 Test 3 Select Test menu 4 Accessories Toogle between Open and Close buttons to ensure proper movement of sampler. Adjust 6 the air valve accordingly. 5 Sampling 7
5 Initial Settings & Adjustments 2 Return to this screen to change sampling time. Time adjustments do not take effect until the cow milking in the robot is finished. Monitor the next sample and adjust accordingly. Set to 60 (see A) 3 4 Set to 0 (see B) Set to 25 seconds For easy reference, make the rack number the same as the robot number (i.e. robot 5 with be rack 5) 1 8
6 Starting the Milk Test 2 Pause Robot 1 Press Sample Button 3 Select Yes 4 Next 9
7 5 Select Open 6 Thread milk line through valve and close 7 Next 8 Verify Settings 9 Next 10
8 To end sampling, turn sampling off, open/close milk valve to remove line, disconnect air hose, and make sure plug is back in receiving jar. 10 Once sampling is active, click to leave on the Process screen If more than 60 cows are being milked, the rack needs to be changed to allow all animals to be sampled. Remove and number full bottles and replace with empty bottles Move spoon back to the start position and change accordingly on robot screen (position 1). Make rack number different for easy reference Make sure you remove enough full bottles to accomodate the extra sampling Pause Robot Sampling has now started so push Pause button again so that you can allow cows back in. 11
9 Initial Setup for Sampling It is always best practice to verify your settings before each test. 1 2 Data Entry Settings 4 3 Choose Milking Select Main Herd 5 Change to One Sample Per Cow Play it safe! To avoid changing your settings by mistake, close this screen after Step 7 by returing to the Home screen 6 7 Verify that this says 'yes' 12
10 Once Sampling Has Started To ensure your 60 bottle rack is near full by evening, start your test mid-morning. Another option is to leave the shuttle hooked up for 24 hours (if needed) and return the next day to process the samples. If other set-up times are being used, please notify your District Manager or Robot Specialist. Sampling should be monitored throughout the day by the owner. Always check the Attention List to ensure all cows have been sampled. These cows should be gathered for milking so the test can be ended. Cows that have been successfully sampled showing rack number and bottle position. A cow must complete a successful previous milking before the sample will be taken. If she did not, you'll find her on the Attention List. Milk Weights: always use 'Day Production' when using the Lely robot sampler. 13
11 Importing Created Files From a Memory Stick Let's go surfin'! But first, always run a virus scan on your memory stick! 1Insert Memory Stick 2 3 Select Reports Analysis/Reports A4 Robot 4 Click Import Report 5 Choose file from your memory stick. 14
12 Individually import all xml files 6 When creating reports, the cow number is always automatically assigned to each report. You can resort any report by clicking on the heading you want to sort by. Importing Files 7 Imported files 15
13 Resampling a Missed Cow Option 1 Hanging out? If you have the time to wait for a cow to resample, follow these steps. If you don t, see option 2. 1 Data Entry 3 Milking 4 General Milking 57 2 Settings 5 To find a cow, enter her number and click search to display the cow list. If you know what group the cow is in, select that group and change sampling method to All Milkings and have the cow reenter the robot to be resampled. PLEASE REMEMBER! After sampling is done, make sure you reset to 1 sample/cow 16
14 Option 2 Have to leave? Follow these steps if you are leaving before the cow enters the robot. Doing this ensures you won t collect a bunch more samples than necessary. 1 Post Milking 2 Double-Click on the Group Select 3 Group 4 5 Click Save Select No You ve now turned off sampling for the whole group. 17
15 Select Select 7 Animal 8 Yes Double-Click 6 on the Cow 9 Click Save Back in business. Cow 57 is now ready to be resampled (see below). Cow #57 is set to be resampled When done, repeat steps 1-5 to return to group sampling. 18
16 Lely Sampler Troubleshooting Please Note! When troubleshooting, it is best to contact the Robot Specialist first PROBLEM: Random samples missing Cause 1: An airlock in the weigh jar prevents milk from flowing to the shuttle jar. Solution: Have dealer permanently remove check ball at the top of the jar. Cause 2: Cow didn t produce enough milk. This is robot-install dependent; limited distance to the shuttle affects cows producing less than 5 kg of milk. PROBLEM: Group of missing samples Cause 1: Blockage inside milk line (rare). Solution: Disconnect, blow out and observe for milk flow. Cause 2: Milk hose has come apart. Solution: Use alcohol swab on both ends to clean before reattaching. PROBLEM: Partially filled bottles Cause 1: Not enough time allotted for bottles to fill. Solution: Increase time at the robot (Settings>Milking Procedure>Sampling>add seconds). Cause 2: Milk is being sucked out of the spoon. Solution: Unscrew spoon ½ turn; cut off stem inside spoon; add a stainless washer under stem, but on top of the spoon for less milk to be sucked out. Cause 3: Milk line is too long and the weigh jar is too low to the ground. Solution: If possible, move shuttle lower and shorten the milk line. Cause 4: Milk Line valve is sticking. More typical of A3s or a robot that has not tested in a while. Solution: Lubricate Milk Valve with Vaseline or have dealer replace it. Cause 5: Bottles not straight. Solution: Check that shuttle is free of being hit. Ensure bottles are clipped clean and inserted straight up and down in the rack. Considering stacking bottles on their rims on every other row if too tight. 19
17 PROBLEM: Spoon is out of position Cause: Too much sway Solution: Check T4C and see where the spoon is supposed to be (noting the cow number) and compare that to the shuttle. Work backwards until you get to the problem spot and determine how many cows were missed. As you remove bottles, assign the proper cow to the correct bottle while working backwards from the end. If this happens early and you want to continue sampling, note the cow number on the last correctly filled bottle and continue. PROBLEM: Extra sway Cause 1: Cylinders lift up unevenly (sticky). Solution: Lubricate cylinders. Cause 2: Weak or uneven springs. Solution: Rotate springs and put the strongest spring on the single spring side or have springs replaced with new ones. Cause 3: Shuttle is rocking. Solution: Adjust the legs/prop up in order to make the shuttle level. Cause 4: Not enough air to operate the shuttle and spoon is not advancing properly. This can be caused by air line leaking or weak air line connectors which should be replaced, or weak air compressor. Some shuttles may have needle valve restrictors that should be open completely. Cause 5: Spoon is hitting the shuttle lid. Solution: Lift and support the lid with a clipped vial lid. To check if shuttle is hitting the lid: Ensure gate is closed and no cows are milking On robot, push TEST; TEST MENU; ACCESSORIES; SAMPLING Toggle OPEN and CLOSE and watch the spoon travel to see if it is hitting a corner on the lid PROBLEM: Some cows milked, but no sample Cause: Cow may not have successfully completed her prior milking PROBLEM: Sampling a missed cow. If 1 or 2 cows need to be sampled, have the cows brought to the robot. After the cow is milked, a sample can be obtained manually from the agitation jar by pulling the plug at the bottom and catching a sample. 20
18 Washing the Lely Sampler The Lely sampler is cleaned using these 3 routine cycles: rinse, soapy wash cycle, final acid rinse (if available) Items Required: Rubber gloves Vasoline to lubricate the cylinders Liquid detergent or bootwash cc syringe Extra boot pail with long brush or a clean sink 1. Rinse Cycle: Disconnect sampler from robot and rinse milk hose, spoon and outside of sampler with a spray hose. 2. Half-fill boot pail with very warm water and add Leminee boot wash or dishwashing soap. 3. Use the syringe to force soapy wash water through milk hose and fill the spoon. (A syringe that can screw onto the milk hose works best.) Move syringe in and out to force water and air into the milk hose. If you discover a pinhole leak, replace the hose, repair it, or cut it shorter. 4. Leave the milk hose and spoon full of solution. Remove the empty syringe and put the end of the milk hose into the top of the spoon to soak the milk hose. Soaking will help get rid of milkstone build-up which can sour the next milk samples taken. 5. Drain soapy water from the hose and spoon. Use boot brush to wash entire sampler and cover with wash solution. Note: edges of the samplers can be very sharp so a long brush should be used to prevent injuries. 6. Using a brush, wash rack inside the boot pail or sink. Use a flask brush to clean the middle part of rack. After sampler is washed and rinsed, remove the end of the milk hose from the spoon and thoroughly rinse out the acid wash solution if it was used. 7. Disconnect the milk hose from the spoon and drain all water. Blow out water from the milk hose manually to dry it. Ensuring the hose is dried is important as any remaining water could freeze on route in winter, and bacteria could grow in summer months. 8. Disassemble the spoon and hand-wash with a brush either in a sink or in the boot pail. Be careful not to lose the O ring and gasket. 9. Once cleaned and rinsed, reassemble the spoon making sure not to over-tighten (always leave it slightly loose). 10. Whenever possible, allow the sampler to air-dry before reassembling or putting the lid back on. This is especially important for the older style samplers where not all the parts are made of stainless steel and the moisture will cause rust. 11. Before the next test, push down on top of all 3 cylinders to ensure none are sticking and if springs are stiff. A weak spring can cause the spoon to not move forward properly and 21
19 ruin the milk test. If any cylinder is sticking, use Vaseline on the cylinder shaft. Never use WD-40 as it will ruin the cylinder seal. 12. Position spoon in Down position (not hanging), disassemble hose from spoon and turn feet inside. Handling the Lely Sampler Park your vehicle close as possible to where robots are situated and use a trolley or cart where provided to bring samplers close to the robot. Ask for help carrying over gates if no other options are available. 22
20 Avoiding Milk Carry-Over We want quality samples and test results! In robotic milking systems, milk carry-over from one DHI sample to another can possibly affect test results. This should be kept in mind when interpreting any pregnancy, disease, or mastitis test results from DHI. By keeping the following information in mind, you will help ensure both quality sampling AND test results. Milk Drip Figure 1 Figure 2 There are three areas for possible milk carry-over: spoon, hose, and weigh jar. 1) Spoon Spoon fill times may need to be adjusted to insure the spoon does not overfill with milk and spill over into other vials. This adjustment is part of the normal setup for sampling. Therefore when starting the sampling, observe the spoon fill level and the vial fill level after the first couple of cows to ensure levels are normal. Make adjustments if needed to the fill time in the robot software. Older robots move the spoon from sample to sample fairly gently with enough time in between samples to allow drainage of the milk into the vial. An area of concern is milk from the surface area of the spoon dripping into the next bottle (Figure 1). This should not affect lab test results. On A4 robots, the vacuum to the shuttle is much higher and could result in spillage of milk from the full spoon as it drops down to empty. An air control valve can be installed on older robots to reduce vacuum. 23
21 Figure 3 (A3 Robot) Figure 4 (A4 Robot) 2) Hose After filling the spoon, the robot sucks out any remaining milk leaving traces on the inside lining which will collect in the lowest section of the hose (Figure 2). The residue milk in the hose is blown back into the weigh jar during the milking of the next cow. It is best to limit potential milk residue by keeping all hoses as short as possible. 3) Weigh Jar This is the most likely point for possible milk carry-over. The amount of visible milk residue may be greater for high component, fast milking cows where more foam is created. Figure 3 shows an example of a well-drained weigh jar in an A3 robot. The pumping process is similar in A3next robots, however, there are more elbows below the jar for possible milk to be trapped. Be sure to take a close look to ensure all milk is drained. If a problem exists where significant milk is left in the jar, it can be corrected by extending pumping time at the robot. In A4 robots, a bladder tank with compressed air is used to empty the weigh jar through suction (Figure 4). If this is not working well, contact the dealer to make adjustments. To further minimize the risk of milk carry-over, you can have the robot system automatically rinse between cows. However, this may not be practical as it would slow down the milking process. To learn how to activate this option on sampling day, please contact your service dealer. 24
BOUMATIC ROBOT AND THE LELY SAMPLE
BOUMATIC ROBOT AND THE LELY SAMPLE Boumatic Robot Sampler Page 1 Boumatic Sampling Steps 2 Double-Click Box id 1 Click Service to pause robot 3 Click Shut to open the sample valve. Hook up milk line in
More informationUSING THE DELAVAL ROBOT SAMPLER
USING THE DELAVAL ROBOT SAMPLER DeLaval Robot Sampler Page 1 DeLaval Check List First time start-up settings done? Are milk lines through all pinch values? Is air pressure to the sampler correct? Is sampler
More informationGalaxy. Galaxy Robot Sampler Page 1
Galaxy Galaxy Robot Sampler Page 1 Galaxy Procedures 1. In the Robot room, set wall switch to Manual 2. Wait until milk pump is finished pumping and set milkbox to Service 3. To open valve, set switch
More informationSetup. Important. Texture Spraying (material supplied from unit)
Setup Setup Important If you are going to stop spraying for more than 5 minutes, turn sprayer off to prevent shortened pump hose life. Do not allow material to dry inside pump, hoses, gun or spray system.
More informationSanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days
Taylor PH61 Cleaning every 14 days Drain the Syrup Lines Remove each syrup feed tube from syrup bottle and let excess syrup drain from the feed tube back into the syrup bottle. When flow of syrup from
More informationMKV MILK METER ICAR approved TECHNICAL MANUAL. Part Number: Waikato Milking Systems NZ Ltd, 2006
MKV MILK METER ICAR approved Part Number: 39860152 Waikato Milking Systems NZ Ltd, 2006 WAIKATO MILKING SYSTEMS NZ LIMITED 119 Maui St, Pukete Industrial Estate, P O Box 20325 Hamilton, New Zealand Phone:
More information5700-E Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5700-E Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationSoft Serve Ice-Cream Machines
Soft Serve Ice-Cream Machines How To Clean, Lubricate and Reassemble Your Gravity Fed Machine Please follow these start-up instructions every time you clean your machine For Spaceman Ice Cream Machines
More informationEFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres
EFX 600 aquamanta TM the experts in aquatic technology >600 Litres Coldwater Tropical Marine 4year guarantee Instruction Manual Important Safeguards This appliance is not intended for use by persons (including
More information60+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS
0+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS Routine maintenance is the best way to get the most out of your appliances. You probably know you should clean the lint filter every time you use the dryer and
More informationQUICK REFERENCE GUIDE FOR OPERATION AND MAINTENANCE
EQUIPMENT SETUP GUIDE Read and follow the BUNN ULTRA Installation & Operating Guide included with your kit. This Equipment Setup Guide is not intended to replace any manufacturer s process or procedure.
More informationINSTRUCTIONS FOR SAFE USE INSTRUCTIONS FOR SAFE USE
USER MANUAL INSTRUCTIONS FOR SAFE USE This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the appliance.
More informationOPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405
CARBON SPOT 30 EXTRACTOR OPERATOR'S MANUAL IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 Diamond Products www.diamondproductsus.com Printed in the U.S.A.
More informationSafety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions
Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 2510 Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationGREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS
Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Note: Zurn Grease Interceptors with grease recognizing sensors are efficient appliances designed to separate grease from water.
More informationCBT Bowl & wrap replacement
CBT bowl & wrap replacement 2 CBT BOWL & WRAP REPLACEMENT Revision History rev. level 01_03.14.2012 rev. level 02_03.19.2012 rev. level 03_03.23.2012 rev. level 04_05.30.2013 NOTE: due to the fact that
More informationClean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationBefore using your machine, you must familiarize yourself with all of its components.
USE AND MAINTENANCE MANUAL FOR THE FOAMTEC 1800 NOTE: As with all electrical equipment, care and attention must be exercised at all times during its use, in addition to ensure that routine and preventative
More informationModel HD 3501 Part No High Pressure Washer Operator Manual
0 15 25 40 25 Nozzle Identification SOAP HD3501 Manual 4/22/02 6:57 PM Page 1 Model HD 3501 Part No. 1.810-999.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2
More informationCBT LW MAINTENANCE GUIDE
CBT LW MAINTENANCE GUIDE PICTOGRAMS Each Signifier displayed here is specific to this User Manual. Menu Previous Advance Note Tip Example Powder Feeder Mixing Bowl Weigh Scale CBP Tanks Control Panel PSD
More informationFleck 5600 Carbon Filter Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 5600 Carbon Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationICED CAPPUCCINO MACHINE Taylor MODEL: 390
4.8.6.3 ICED CAPPUCCINO MACHINE Taylor MODEL: 390 LOCATION: Front of House WHEN CLEANED: Daily, Weekly, Monthly, Seasonal TOOLS/SUPPLIES REQUIRED: Salmon Cloth 2 or 3-Compartment Sink Sink Detergent Sanitizer
More informationSAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.
TABLE OF CONTENTS Machine Components Safety Precautions Machine Set Up Machine Operation Machine Maintenance & Storage Troubleshooting Technical Specifications Parts Lists Wiring Diagram 1 2 3 3-4 5 6
More informationCapraLite. Owner s Manual. Milking Machines. Built by: Apparatus Mfg., Inc. 13 Commerce St Poughkeepsie, NY 12603
CapraLite Milking Machines Owner s Manual www.capralite.com Built by: Apparatus Mfg., Inc. 13 Commerce St Poughkeepsie, NY 12603 Page 2 Getting your Machine ready Your machine is almost ready to use. For
More informationInstallation & Operators Manual
Installation & Operators Manual Eco, Hydro and Duo under counter range Part number 902.0001 Revison B Installation and Operation instructions For Classeq under counter range of glass and dishwashers. Section
More informationFeatures. QuickStart. Professional III/GameSaver Turbo. Features of Your FoodSaver Appliance. Accessory Hose Storage (under lid) Manual Seal Button
QS.Pro3_GSturbo_v3 6/29/04 11:22 AM Page 1 QuickStart Professional III/GameSaver Turbo Shown Professional III; GameSaver Turbo operates in the same manner. Features of Your FoodSaver Appliance A B C D
More informationDEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST
COMFORT...BUILT TO LAST 11 PINT DEHUMIDIFIER USER MANUAL FOR MODEL: 3PAD11 Before using your dehumidifier, please read this manual carefully and keep it for future reference, along with your receipt. CONTENTS
More information7800 Neutralizer Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 7800 Neutralizer Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationInstallation and Setup
NFORMATION NO: 007 Self Fill Lavazza Colibri with changegiver Congratulations on choosing to drink great coffee using the unique Lavazza pod vending system. The machine is easy to use. Follow the simple
More informationPolyMax H2-24 Dutch Bucket System
11234 PolyMax H2-24 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. 2017 FarmTek All Rights
More informationInstallation Manual PS-200 & PS-201
Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 1650 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationAs part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.
CONGRATULATIONS on your purchase of a Viper product, and welcome to the V.I.P. family. We appreciate your business and will do everything in our power to keep you happy with your purchase for many years
More informationVIVA ace Quick Operation Guide
VIVA ace Quick Operation Guide Contents 1. Installing the Holder Bar and Arm...2 2. Connecting the Motor, the Scaler, and the Syringe...3 3. Installing the Vacuum...4 4. Installing the Water Bottle...5
More informationModel K 5800 G Part No
K5800G Manual 11/30/01 5:02 PM Page 1 Model K 5800 G Part No. 1.194-103.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2
More informationModel LF-310 Air Operated
Microflush Half Gallon Toilets Model LF-310 Air Operated Installation/Service Manual P/N 24156 452 East Hill Road Fax: 707.459.6617 Willits, CA 95490 USA E-mail: info@microphor.com Phone: 707.459.5563
More informationACME DIAGNOSTICS STANDARD OPERATING PROCEDURE
ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE Procedure Number: II.01.200a Effective Date: 09/14/99 Review and Update: 09/2003 TITLE: ADVIA 120 ROUTINE MAINTENANCE PURPOSE AND PRINCIPLE: The ADVIA 120
More informationWARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...
4 TABLE OF CONTENTS Technical specifications... 1 Warranty... 2 Important precautions Read first!... 3 Safety features and electrical power information... 5 Parts and diagram list... 6 Assembly and operation
More informationInstallation Manual PS-225 & PS-275
Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationHow To Drain A Front Loading Washing Machine Before Moving
How To Drain A Front Loading Washing Machine Before Moving You will want to do this if you have a front load washer that is not spinning. The washing. When you drain that out, it gives off a large amounts
More informationModel K 3000 G Part No
K3000G Manual 11/30/01 4:56 PM Page 1 Model K 3000 G Part No. 1.133-110.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2
More informationElectric Honey Extractor
Electric Honey Extractor Instruction Manual SKU: BEE-V004E Scan the QR code with your mobile device or follow the link for helpful videos and specifications related to this product. https://vivo-us.com/products/bee-v004e
More informationIMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic
INSTRUCTIONS PERTAINING TO; RISK OF FIRE, ELECTRIC SHOCK OR HARM TO PERSONS IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic precautions should always be followed, including
More information3/4 HP Model Trimmer Operating Instructions
3/4 HP Model Trimmer Operating Instructions Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com Technical Specifications
More informationHFG 12 and 24 Hydrogen Generators Installation Instructions
HFG 12 and 24 Hydrogen Generators Installation Instructions Model 12 Model 24 PLEASE READ THESE INSTRUCTIONS FROM BEGINNING TO END BEFORE STARTING YOUR INSTALLATION. If you are still having problems after
More informationSRI 8610C GC for PCB in Transformer Oil Analysis November 2014
The SRI 8610C Gas Chromatograph ( GC ) is installed on any bench top. When the red lid is raised, you can see the column oven, injector ( on-column type ), detector ( DELCD ) and gas stream dryer. The
More informationModel HD 3000 Part No High Pressure Washer Operator Manual
Model HD 3000 Part No. 1.187-116 High Pressure Washer Operator Manual Overview..................................1 P recautions...............................1-2 Assembly Instructions.........................3
More informationModel K 520 M Part No
Model K 520 M Part No. 1.069-680.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents...
More informationBMW E36 Thermostat Removal And Coolant Flush
BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could
More informationMANUAL OWNER S. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE.
OWNER S MANUAL Operating and Servicing Instructions www.hoover.com.hk HW-FM-HKA IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE. THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY. IF USED COMMERCIALLY
More informationElectric Pressure Washer
Electric Pressure Washer S1900 039-8575-4 OWNER S MANUAL If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664) PLEASE
More informationHID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service
HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service What you will learn Introduction Installation Operation Maintenance Take It Apart Diagnostics HID Ice Maker-Dispensers HID models
More informationClean Water Made Easy
Clean Water Made Easy www.cleanwaterstore.com CWS Plus Neutralizer/Birm Blend Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationHigh Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB
Model HD 2700 DB Part No. 1.194-116 Model HD 2700 DH Part No. 1.194-117 Model HD 3000 DH Part No. 1.187-115 Model HD 3500 DH Part No. 1.810-997 Model HD 3500 DB Part No. 1.810-998 High Pressure Washer
More information- 2 - IMPORTANT SAFETY REMINDERS IT IS IMPORTANT THAT YOU:
USER MANUAL IMPORTANT SAFETY REMINDERS This cleaner should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the appliance.
More informationGetz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System
Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED
More informationImportant Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3
User s Manual Index Topic Important safeguards 03 Safety features 05 Parts and accessories 05 Before first use 06 Operating instructions 06 Programme settings 08 Care and cleaning 09 Pressure canning guide
More informationOPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION
OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION THIS SYSTEM IS TO BE USED FOR REMOVING CONTAMINATED DEBRIS FROM EDDY CURRENT PROBES DURING STEAM
More informationO p e r a t i n g I n s t r u c t i o n s
O p e r a t i n g I n s t r u c t i o n s www.masterblasterfoam.co.uk Page 1 of 10 Contents Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Introduction & Features Safety Instructions Warnings,
More informationBACK WASH INSIDE THE SPA
BACK WASH INSIDE THE SPA Lower the temperature to 90 degrees and let the unit run approximately 10-15 minutes. This gives the heating element the chance to cool down. Now unplug the power pack Using a
More informationFleck 7000 Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationFleck 2510 SXT Catalox Installation & Start Up Guide
Fleck 2510 SXT Catalox Installation & Start Up Guide For Catalox Filters with PotPerm Bleach Solution Tank Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationOPERATION MANUAL ALPHA ALS WET / DRY IMPORTANT SAFETY INSTRUCTIONS. Read all instructions before using or servicing machine.
. OPERATION MANUAL ALPHA ALS WET / DRY IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using or servicing machine. WARNING: Shock or electrocution hazard. ALWAYS unplug machine before performing
More informationGet Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:
User Guide Vax Careline: AU: 1300 361 505 NZ: 0800 800 900 Carpet Washer Get Cleaning... What s your Vax s model number? W8 W8 W0 W0 W0 W W W W W What s your serial number? (Located on the base of the
More informationPet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:
V-027P Rapide Pet User Guide 10/7/07 10:05 Page 14 EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: VAX Limited, hereby on our own responsibility declare that the products V-027/V-027PT/V-027P/CCW-701
More informationTRAINING OUTLINE POST-MIX DAILY MAINTENANCE
TRAINING OUTLINE POST-MIX DAILY MAINTENANCE 1. System Types A. Post-Mix a. Countertop b. Ice-Cooled c. Remote with Tower B. Pre-Mix a. Countertop b. Ice-Cooled c. Remote with Tower 2. Check CO2 A. Check
More informationElectric Pressure Washer
Electric Pressure Washer S1700 039-8574-6 Owner s Manual If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664). PLEASE
More informationMopit 4 Operator s / Service Manual
Mopit 4 Operator s / Service Manual FOR PARTS AND SERVICE 1-800-290-2833 To view Mopit 4 instructional videos scan this qr code with your smart phone. You can also find Mopit 4 instructional videos on
More informationReview this manual before operating cleaner.
Owner s Manual English pp. 1-8 Espanõl pág. 9-12 Français p. 13-16 Thank you for selecting a HOOVER product. This cleaner was inspected and packaged carefully before being shipped from the factory. If
More informationExplorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.
Explorer 1500 Carpet Extractor Model No.: 608808 609231 Can. Operator and Parts Manual CleaningPartsDirect.com 662-393-3045 NOBLES 12875 RANSOM STREET HOLLAND MI 49424 U.S.A. CUSTOMER SERVICE: 1-800-365-6625
More informationNupulse Original Claw Cow Milker
Instruction Manual for Nupulse Original Claw Cow Milker Copyright 2013 Hamby Dairy Supply You may print manual for own non-commercial use, but not for resale. HAMBY DAIRY SUPPLY 2402 SW Water St. Maysville,
More informationInstallation & Operating Guide
5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase
More informationH68 Pro FAQ Customer Service Product Care
H68 Pro FAQ Customer Service Who is Moneual? You can find Moneual's company information by clicking here How do I contact Moneual? You can find Moneual's contact information by clicking here Where can
More informationCONSTANT SUCTION UNIT
CONSTANT SUCTION UNIT OPERATOR/MAINTENANCE M A N U A L Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive Gurnee, IL 60031-4099 1-800-662-5822/847-855-0800 Fax: 847-855-6218 www.aerosinstruments.com
More informationWS1 Softener Installation & Start-Up Guide
WS1 Softener Installation & Start-Up Guide Thank you for purchasing a Van Isle Conditioner. With proper installation and a little routine maintenance your system will be providing treated water for many
More informationWS1 Greensand Installation & Start Up Guide
WS1 Greensand Installation & Start Up Guide Thank you for purchasing a WS1 Water System for the removal of iron, manganese and hydrogen sulphide gas. With proper installation and a little routine maintenance
More informationMobile Milker. Filling the oil reservoir to HALF FULL
1 2 Mobile Milker Upon receiving the unit check if there is any visible damage to pump, motor etc... If there is any damage do not attempt to run the unit! Call 800-245-8222 for assistance. Preparing to
More informationK 3.97 M. Specifications or visit our website: In USA call: Part No
K 3.97 M High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4-5 Operating Instructions... 5-6 GFCI Instructions... 6 Using the Accessories... 6 Working with
More informationMODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)
Order Number: PMMA091040CE Vacuum Cleaner MC-UL592/MC-UL594 SPECIFICATION MODEL MC-UL592 MC-UL594 POWER SOURCE 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H) 1200-1300
More informationLETTER TO FAMILY. Science News. Cut here and paste onto school letterhead before making copies.
LETTER TO FAMILY Cut here and paste onto school letterhead before making copies. Dear Family, Water is a unique earth material, the only material on Earth that occurs naturally in all three states of matter:
More informationModel K 240 plus Part No
Model K 240 plus Part No. 1.223 585.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories...
More informationNichole Ernst CEO Powerhouse International
Dear Valued Customer, Thank you so much for your order. We are a family-owned business in Lincoln, NE and customer service is our priority. If you have any questions about your product, please feel free
More informationDetailed Cleaning Instructions
NY Thermal Inc. Tel: (06) 67-6000 Toll Free: 1-800-688-27 Fax: 1-06-432-113 Web: www.ntiboilersl.com Email: info@ntiboilers.com Style Heat Exchanger occupants or, death. This boiler must be serviced by
More information- website: Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK
V-026PT User Guide.qxd 7/9/06 15:13 Page 12 EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: Vax Limited, hereby on our own responsibility, declare that the product V-026PT is manufactured in compliance
More informationClean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Tannin Filter Installation & Startup Guide For Tannin Filters with Vortech Distributor Screen Thank you for purchasing a Clean Water System! With
More informationModel K205 M Plus Part No
Model K205 M Plus Part No. 1.223-820.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-3 Assembly Instructions.........................3
More information2001 Smith Eastern Corporation
Automatic Spray Equipment Cleaning System User s Manual UG-45V Smith Eastern Corporation 10630-S Riggs Hill Road Jessup, Maryland 20794-9425 USA 301.497.7600 800.937.HVLP (4857) Fax 301.497.7613 cleaner@airverter.com
More informationINDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP
INSTRUCTIONS FOR INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP MODEL NO: PC200SDAUTO.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according
More informationEDS6051 TUMBLE DRYER USER MANUAL
EDS6051...... TUMBLE DRYER USER MANUAL 2 www.electrolux.com Contents Important Safety Instructions Use - - Dryer Safety... Page 2 Fire Hazards... Page 2 - - The Control Panel... Page 6 Operating Sequence...
More informationModel K 330 M Part No
Model K 330 M Part No. 1.994-916.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-3 Assembly Instructions.........................3
More informationINSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION
INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / 27-009, 27-010, 27-015, 27-020 IMPORTANT INFORMATION UNATHORIZED CHANGES OR ALTERATIONS TO ANY LINCOLN PORTABLE VACUUM SYSTEM WILL AUTOMATICALLY
More informationALLERGEN MIXING ASSISTANT
ALLERGEN MIXING ASSISTANT User Manual 9495 SW Locust Street Suite E Portland, OR 97223 (503) 379-0110 Fax: (503) 715-1378 www.xtractsolutions.com SM026R2 Welcome to Xtract Solutions Thank you for purchasing
More informationMedia Service Instructions 1500 Series BAT Media Plants
R Media Service Instructions 1500 Series BAT Media Plants J-500 MEDIA SERVICE Read these instructions and perform every step. After servicing 2 or 3 installations, you will only have to refer to these
More informationCWS Plus Sediment Filter Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com CWS Plus Sediment Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationMitocell: Instructions for Use
Mitocell: Instructions for Use 1 Introduction The Mitocell (MT200) is designed for the measurement of the respiration rate of either 50 or 100µl sample volumes of mitochondria and cell suspensions. The
More informationTornado Operations & Maintenance Manual
Tornado Industries, LLC 333 Charles Court West Chicago, IL 60185 www.tornadovac.com Tornado Operations & Maintenance Manual MODEL NO. 99414 Form No. L9740AB Tornado Industries, LLC. All rights reserved
More informationINSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841
MODEL UC 60e INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 www.cmadishmachines.com TABLE
More informationMODELS: TJ45 TJ90 Operator s Manual
ICE DISPENSER MODELS: TJ45 TJ90 Operator s Manual Part No. 90614 Revision: H Revision Date: May 26, 2014 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing
More informationGlass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:
Glass and Dishwashers ECOMAX 402/452/502 (incl. Australian 452-90/502) INSTALLATION AND OPERATION INSTRUCTIONS (original instructions) Starting from Serial No.: 8663 4000 REV. 05.10.2015 EN IMPORTANT NOTES
More information