Product Manual. Model Number Range XX XX

Size: px
Start display at page:

Download "Product Manual. Model Number Range XX XX"

Transcription

1 Product Manual Model Number Range XX XX Applies to Index remote cooler range: - Index21 AC, Air cooled models with part code commencing XX - Index21 WC, Water cooled models with part code commencing XX

2 Contents Section Content Pages 1. Introduction 1 2. Installation Instructions Service maintenance instructions 8 4. Fault finding Product Photos Data Sheets Parts Lists and exploded views Wiring Diagrams 20-21

3 1. Introduction The Index remote cooler is a functional and robust remote cooler, designed with the installer and service technician in mind. It s simple and effective operation delivers reduced operating costs and reduced life costs. The Index is built to BDA standards, ensuring that the lid is interchangeable, there is simple exchange of serviceable parts and standard cassette product coils. Index also has a small footprint, minimising the valuable space taken up in account cellars or back room IMI Cornelius is able to offer one of the most extensive ranges of equipment together with a support package which is second to none. Page 1 of 21

4 2. Installation 2.1. Requirements Summary Installation must be carried out by a suitably trained person and comply with national and local codes for connection to the electrical supply. - Unit must be installed indoors on a dry, level surface - Good ventilation (minimum 100 mm gap around unit) - Access to side, top and front - Electrical - 13 amp, 230V - Grounded, switched (preferably an RCCB) - Socket within 2m of unit INDEX 21 AC (air cooled) - Outside a chilled cellar, close to beer storage - Ambient temperature 10 to 43 C INDEX 21 WC (water cooled) - Base unit inside chilled cellar - Ambient temperature o Base unit 10 to 38 C o Heat Discharge Unit -10 to 35 C - Maximum distance between base unit and heat discharge unit o 30 metres using 1.5mm2 cable o 50 metres using 2.5mm2 cable - Glycol Mix- must be pre-mixed before adding to the unit o Glycol 30% / Water 70% (minimum) o Glycol 40% / Water 60% (maximum) - Prepare maximum 12 litres for 50m flow and return of 11.5mm ID - Minimum glycol flow rate 4.5 litres/min Page 2 of 21

5 2.2 Installation Instructions Please read carefully before installing the unit Please follo w these in structions carefully. Only if the remote unit is pro maintained will trouble free operation and customer satisfaction be achieved. perly installe d and General description This is a remotely sited cooler used for cooling drinks such as beer, lager, cider & stout. Incorporating mechanical temperature control this unit is suitable for the utilization of water as the product cooling medium and for the formation of an ice reserve. A recirculation pump provides both constant agitation of the water bath and a flow of re-circulating chilled coolin g medi um fo r python cooling. The remote co oler is fully automa tic, therefo re, the electrical supply must not be interrupted (unless access for mai ntenance is required), otherwise reduced performance and reliability will occur. Safety Read this booklet before undertaking installation or maintenance. Recognize safety alerts isolate the power supply before removing panels. DANGER - WARNING - CAUTION - Indicates an immediate hazardous situation which, if not avoided, WILL result in serious injury, death, or equipment damage. Indicates an immediate hazardous situation which, if not avoided, COULD result in serious injury, death, or equipment damage. Indicates an i mmediate hazardous situation which, if not avoided, MAY result in minor or moderate injury, or equipment damage. Handling & transportation Keep the remote cooler in an upright position and do not drag over rough floors or down steps. Upon receipt, unpack the unit carefully and visually i nspect for an y damage which may have b een sustain ed during tra nsit. Record th e n ature of any damage on th e couri er s delivery note and, at the same time inform your supplier. Once the unit is in position, do not move when filled with water Installation Installation must only be carried out by suitably tra ined p erson and m ust comply with national and local codes for connection to electrical supplies. It is recommended that the installation is protected by an RCCB (Residual Current Circuit Breaker). Siting Remote A/C & W/C Units Remote units are designed for indoor use only. The re mote units may be sited within cooled cellars, store roo ms or oth er appropriate internal areas where the ambient air t emperature is betwe en 5 C and 43 C (A/C), 38 C (W/C). Remote coolers should not be exp osed to liqui d spillage, spray, steam or humidity at a higher level than 90% rh. Site the cooler within 40 metre s of the point of dispense. Locate the cooler within 2 metre s of a n earthed, switched, 13 Amp, 230V 5 0Hz socket which is accessible for isolation of the equipment. The socket must be installed to comply with current IEE regulations. Page 3 of 21

6 Site the cool er on a firm l evel surface, protect fro m physical da mage and do not place items on top of, or underneath the cooler. Clear space must be provided above the unit. Allow 50mm cl earance around the unit to aid air circulation and keep the front of the unit clear to allow an unimpeded air supply to enter the cooler. Air vents should never become obstructed or blocked. Access should be possible to the front panel for ease of service. Do not stand on this unit. Installation General WARNING - The appliance must be earthed. If not already fitted, fit the appropriate electrical plug to the service cord. The fu se rating is stated on the rating plate. With the u nit unpacked and in p osition, remove all coil caps, but do not connect to an electrical supply at this stage. Filling the product water bath. Do not u se de-ionised water or a dd any su bstance to the water (u nless a pproved by Cornelius). Do not leave hose pipes unattended whilst filling the product water bath as the unit may become flooded. Open the filler / inspection hatch on the lid of the cooler. Fill with cool clean water until liquid starts to flow from the overflow Stop filling and close the filler / inspection hatch on the lid of the cooler The overflow is a 15mm connection. A fitting or pipe can be pushed directly into this to direct the condensate water to drain Discharge unit (water cooled models) The disch arge coole r sho uld be moun ted on an exterior wall, not south fa cing, and p rovide access for pipes and ele ctrical cable t o the b ase unit (m aximum 50m ). If n o exterio r wall is available the n mount insi de on a wall in a cool ro om with plen ty of fresh ai r ventilation. Avoid warm ar eas (i. e. cup boards o r sm all storerooms). Secure the d ischarge cooler to the cho sen location and fix (follow instruction guidance from the discharge cooler). Using a mini mum 1.5mm 2 two co re ca ble, con nect the Disch arge Cool er to the rem ote W/ C cooler. Connect the two core cable to the quick fit terminal block, this is located at the rear of the W/C cooler (Note: This is a nominal 24V 50Hz supply). Complete the glycol circuit by connecting the pipe work between the remote W/C cooler and the discharge cooler utilizing 15mm Service Valves. WARNING - As the glycol lines will circulate a warm glycol mix it is important for safety reasons that suitable tubing is used. Consult a specialist tubing manufacturer or contact Cornelius. WARNING - PVC tubing, whether braided or not, is not suitable for this application. Page 4 of 21

7 The tubing ID m ust be sufficient to ensure a minimum flow rate of 4.5 litres/ minute in the glycol circuit. It is recommended that an I D o f at least 11.5mm b e u sed. Avoid u sing elbo w j oints a s these cause pressure drops. The tubing must not be routed next to hot surfaces or sharp edges. Avoid ups and downs in each glycol line as this may create air lo cks. Do n ot kink or crush the tubing, ensure minimum bend radii of 100mm and support where necessary. WARNING The lines should never be taped together or insulated. Priming the discharge unit coolant circuit (water cooled models) CAUTION As the python i s n ot conne cted at this stage di sconnect the electrical su pply connection for the recirculation pump from the socket on the rear panel at the back of the cooler. Mix monop ropylene glycol and water t o give a sol ution of Mini mum 30% gl ycol 70% wa ter, Maximum 40% glycol 60% water. Glycol should be mixed in a clean container. CAUTION Always mix the water : glycol before filling the system. WARNING - Do not use ethylene glycol. Ensure sufficient glycol/water mixture is avail able for filling the during priming before switching the remote W/C cooler on. coolant bottle and topping up You will need to prepare: 4 litres of glycol/water mix to fill the water cooled unit coolant system. In addition the compl ete system will re quire top ping up with the followin g qua ntities to give a Minimum 30:70 to maximum 40:60 glycol/water ratio whilst priming: 2.1 litres for every 10m of 11.5mm ID tubing 4.2 litres for every 20m of 11.5mm ID tubing 6.3 litres for every 30m of 11.5mm ID tubing 8.4 litres for every 40m of 11.5mm ID tubing 10.5 litres for every 50m of 11.5mm ID tubing Fill the coolant reservoir to the maximum level (indicated on the front of the coolant reservoir). CAUTION ensure all service valves are in the op en position prior to switchi ng on the re mote unit Switch on the mains electrical supply to the remote W/C unit. As the cool ant circuit pri mes, the level of c oolant in the rese rvoir will dro p. Keep filling the reservoir with the p repared 30:70 / 40:6 0 glycol/water mixture, en suring the level does not drop below the minimum or exceed the maximum levels indicated on the front of the reservoir. CAUTION do not allow the base mounted coolant pump to run dry. Page 5 of 21

8 Connecting the python & product lines. CAUTION Ensure the electrical supply connection for the recirculation pump is disco nnected from the socket on the rear panel at the back of the cooler. If the mains electrical supply to the remote cooler is not already switched on, switch it on now. CAUTION - All tubing/pythons must be routed to prevent undue stress, tight bends or kinking. From the product python connect the recirculation lines to the flow and retu rn of the top mounted recirculation pump on the remote cooler. It is recommended that this connection is made utilizing 15mm Service Valves to aid with future service requirements. CAUTION - Ensure the recircul ation li nes a re loo ped at the po int of dispen se an d plug the electrical supply lead for t he recirculation pump into the so cket on the re ar panel at the ba ck of the cooler. Check all plumbing connections for leaks. As the python recirculation lines prime the level of liquid in the product water bath will drop. Refer to section Filling the product water bath to top up to correct level. Connect pro duct in and python su pply to each co nnection on the pro duct coils of the re mote cooler. Utilize 3/8 push fit connectors. Note: All lines to be well insulated to the requirements of the system. Operation Once connected to the mains ele ctrical su pply allo w time fo r th e coole r to build a full ice bank (refer to relevant Product Data Sheet for time to full icebank), the cooler is now ready to use. Note: there are no user adjustable controls on this remote unit. Service information There are no user serviceable items inside the equipment. Maintenance and repairs must only be carried out by a properly qualified trained person. Should the unit malfunction, suffer spillage, physical damage or component failure SWITCH OFF AND UNPLUG THE UNIT FROM THE MAINS ELECTRICAL SUPPLY. CAUTION Do not switch the unit off and on within 5 minutes. If any maintenan ce/servicing is requi red, refe r to the fault fin ding ch art, wirin g diag ram and exploded drawings contained in the manual. Only use Co rnelius reco mmended spare p arts for cooler mai ntenance, fail ure to d o so will invalidate cooler approvals and warranty. Condenser It is re commended that the co ndenser i s cleaned with a soft bru sh o r va cuum cleaner at least every 6 months. Product water bath It is recommended that the water in the water bath is replaced annually. - Melt the ice bank. - Drain the water bath. - Refill the water bath. Page 6 of 21

9 Description of controls Refrigeration system reset The Water Cooled remote utilises a refrigeration system cut out switch. This switch is of manual reset type and is located in the refrigeration system compartment, behind the removable service panel. Upon activation of th e switch, diagnose the cause and rectify the problem. Once the problem is resolved allow 10 minutes then press the Refrigeration System Reset button. Preventative user maintenance For all of the below, once the maintenance is carried out, follow the Installation instructions for re commissioning the unit Switch off and unplug the unit during user maintenance operations. In the event of the unit malfunctio ns or suffers spillage or physical damage, unplug the unit from its electrical supply. CAUTION - Do not switch the unit off and on within five minutes. Do not attempt to remove the protective covers. Product water bath level If the cooler becomes noisy make s a gurgling sound, this is d ue to a low p roduct bath water level and will result in reduced cooling capacity. To remedy this follow the instructions for Filling the product water bath Sanitizing Product Coils WARNING - Under no circumstan ces should boiling water or steam be used wi th this unit as it may result in pe rmanent damage. The maxi mum tem perature pe rmissible for any liquid used for sanitising is 40 C. Sanitize when taste is tainted or periodically as advised by the beverage supplier. Important flu sh with pota ble water, th en chlori nated alkaline solution. CAUTION - It is important tha t the sanitizing a gent manufacturer s procedure a nd safety precaution s a re followed when using caustic chemicals. Rinse through with potable water to remove cleaning solution and test with litmus paper. The 1989 Electricity at Work Regulations require periodic testing of electrical equipment and this should only be carried out by a competent person. Directive Compliance: EMC Directive (2004/108/EC) Low Voltage Directive (2006/95/EC) Machinery Directive (89/392/EEC) Page 7 of 21

10 3. Service Maintenance Instructions 3.1. INDEX 21 AC Check that the water level in the water bath is up to the overflow. Check and clean the rear Condenser fins. Dirt and dust can block the air vents in the condenser, severely reducing the effectiveness of the refrigeration system. Check that there is adequate airflow through the unit, ensuring enough space all round and that there are no obstructions in the front of the air flow vents. Check ambient temperature is between 10 C and 43 C. Check the condition and the effectiveness of the Python insulation. Check for restrictions in the water recirculation python lines (6 ltr per min) Check for algae growth in the water bath. At regular intervals, to be determined by the owner and/or the user, the cooler should be checked for electrical safety INDEX 21 WC Check that the water level in the water bath is up to the overflow. Check that the Discharge Unit fan is working and that there are no obstructions or blockages of the air vents. Check and clean the heat exchanger fins on the back of the Discharge Unit. Dirt and dust can block the air vents in the heat exchanger, severely reducing the effectiveness of the refrigeration system. Check ambient temperature is between 10 C and 38 C (base unit) -10 C and 35 C (heat discharge unit). Check the condition and the effectiveness of the Python insulation. Check the Python for correct water recirculation. Check for algae growth in the water bath. At regular intervals, to be determined by the owner and/or user, the cooler should be checked for electrical safety. Check the glycol lines are not kinked or crushed. Check for leaks. Check the strength of the glycol/water mix using a refractometer (20% brix minimum) or a hydrometer Check the level of coolant (Water/Glycol) in the reservoir and re-fill as necessary with a 30% Glycol 70% Water mix using a clean container Page 8 of 21

11 4. Fault Finding Chart Maintenance and repairs must only be carried out by a properly qualified and trained person. Always switch off and unplug the equipment before servicing or repairing the unit. PROBLEM POSSIBLE FAULT REMEDY SERVICE TIP 1. Totally Inoperative Is supply fuse blown or has circuit breaker tripped? Yes Is fuse or circuit breaker size correct? Yes Is line voltage within 240v +6/-10%? No Loose connection or broken wire in supplying wiring to unit Replace or reconnect wire Install within 2m of an electrical socket No Incorrect size device Install correctly sized device See rating plate for current consumption Yes Loose connection or broken wire in supply wiring to unit Replace or reconnect wire Charred connection indicates poorly crimped electrical connection No Is line voltage too high or low? Yes Improper voltage supply Consult electrical supplier Voltage range 207v to 253v No Unit malfunction Contact IMI Cornelius 2. No Cooling Is line voltage within 10% of nameplate voltage? Yes Is compressor cold, fan motor and green neon on? No Compressor doesn t start, hums and trips on overload No Compressor starts but start winding does not switch off No Compressor running hot. Compressor starts and runs short, Cycling on overload protector No Go to 1. Totally inoperative Go to 1. Totally inoperative Go to 1. Totally inoperative Yes a) Fault y thermostat b) Lo w water c) Refrigeration system cut out Yes a) Start capacitor shorted or blown b) Start relay will not close or is burned out c) Compressor motor is faulty d) Compr essor ceased Yes a) Imprope r wiring b) Relay failing to open c) Ex cessively high discharge pressure d) Open or shorted windings in compressor e) Tight compressor (binding internally) Yes a) Defective compressor cut out b) Excessively high discharge pressure c) Suction gas too hot d) Low refrigerant charge a) Replace b) Top up c) Diagnose cause and reset a) Check or replace capacitor if required b) Check connections, replace relay is necessary c) Replace compressor d) Replace compressor a) Replace and reconnect wiring b) Replace relay c) Clean condenser or replace fan motor d) Replace compressor e) Replace compressor a) Replace thermal cut out b) Clean condenser or replace fan motor c) Water bath too hot- cool to below 30 c d) Repair leak and recharge refrigerant a) Do not kink phial tube b) See install instructions c) Always isolate electrical supply before undertaking repairs a) Check for paper debris of blown capacitor b) Relay will rattle if OK c) See rating plate for gas charge d) Always fit new drier a) Isolate electrical supply before repair b) Ensure correct relay is used c) Use vacuum cleaner or soft d) See rating plate for gas charge e) Always fit new drier a) Isolate electrical supply before repair b) Leave 100mm gap around unit c) n/a d) Traces of oil are a good indicator of leaks Page 9 of 21

12 3. Warm Product Is compressor running? No Go to 2. No Cooling Go to 2. No Cooling Go to 2. No cooling Yes Low water bath level Yes a) Leaks b) Insufficient water recirculation python priming No Ice bank build? Yes a) Water recirculation pump not electrically plugged in or failed b) Blockage in python c) Product coil too short No a) High ambient b) Condenser blocked c) Defective condenser fan moor assembly d) Loss of refrigerant charge e) Incorrectly specified cooler f) No coolant in glycol tank g) Coolant base pump failed h) Coolant not flowing through discharge cooler i) Discharge cooler airflow blocked j) Discharge fan failed k) Transform er failed l) Mechanical thermostat failed m) Poor airflow through condenser n) Too many coils in the cooler for such a high demand o) Product inlet temperature too high p) Excessive python length a) Check for leaks and fill to overflow b) Ensure python is fully primed on install a) Plug pump into socket on the base or replace failed pump b) Check for kinks or algae growth c) Fit longer coil a) Change ambient or re-site cooler b) Clean condenser grille or remove objects in front of the condenser which are restricting air flow into the unit c) Replace condenser fan motor assembly d) Check for leaks, repair and recharge e) Leave for an hour. If ice bank still does not reform, check specification against location f) Refill with 30% Glycol, 70% Water. g) Replace h) Ensure all valves are open. Check lines are not kinked or crushed. Ensure pump is primed. i) Clear blockage. Clean fins as necessary j) Replace fan motor k) Replace transformer l) Replace m) Clean condenser & ensure adequate space n) Reduce the number of products on the cooler. Fit further cooler if necessary o) Reduce the temperature of product storage area p) Limit python length to 40m maximum (dependent on product throughput) a) Ice build will displace water to the overflow b) Insufficient python insulation seriously reduces cooler performance a) Run cable to ensure cable cannot be accidentally dislodged in future b) Add algae inhibitor in the water bath c) Extra long coil takes up two spaces a) Ensure unit works within ambient range 5-43 c (A/C) & 5-38 c (W/C) b) Leave 100mm clearance around unit c) Unbalanced fans cause motor failures d) Never leave service valves on cooler e) 1000 pints per hour peak capacity theoretically. Python load will reduce this f) Keep tank full to overflow, check for leaks g) Refrigeration system cut out isolated the base mounted coolant pump h) Never insulate glycol lines & bleed all air. i) Use 1.5mm 2 cable to connect discharge cooler to base cooler j) Discharge fan runs with compressor k) Trace wiring to supply at unit to eliminate possibility of loose connections l) Ensure new stat Phial is in original position m) Always leave 100mm air gap n) Maximum 12 spaces o) Maximum 43 c (A/C) & 38 c (W/C) p) Avoid hotspots when installing the python, a separate python cooler maybe necessary. 4. No Product Ice bank too large. Product frozen Erode ice around thermostat with warmer water (less that 60 c) check and replace thermostat if faulty 5. Product too Cold a) Lo w throughput b) Coil too long a) Reduce number of taps per product b) Fit shorter coil Do not kink phial tube a) N/a b) Short, long or extra long coils available Page 10 of 21

13 5. Product Photos Index21 AC Index21 WC Heat Dump Exchange Unit Page 11 of 21

14 6. Product Data sheets Product data sheet Index21 AC Date: 25 Feb 2010 Issue No: 5 Page: 1 of 2 Performance Nominal icebank pull down:( water 10 o C at 24 o C ambient): Icebank weight:: Thermal capacity icebank: Maximum ambient temperature: Dimensions Height: Width: Depth: Weight: Unloaded Packed Operational Electrical Mains supply: Run current: Start current: Fuse: Supply: Model number: XX 5 hours 25kg nominal 8375KJ (2000 Kcal) 43 o C 930mm 570mm 600mm 66kg 67kg 130kg 230v 1ph 50Hz 5.0 amps 31 amps 10 amps 2m mains cable 3 pin UK Style plug Refrigeration Compressor: Compressor starting torque: Compressor duty: (-10 o C Evap temp) Evaporator type: Condenser type: Expansion device: Refrigerant type charge: Control type: Fan Motor Output: Speed: Direction: Protection: Fan blade: Diameter Pitch Option 1: Option 2: Option 3: Option 4: 21cc High starting torque 750 watts 12.7mm dia tube Air Cooled Cu/Al construction Capillary 3M x 1.5mm I.D. R134a refer rating plate Mechanical Ice bank thermostat Mechanical Incool thermostat Adjustable mechanical thermostat Electronic temperature controller 11 watts 1300 rpm Counter clockwise shaft end Impedance 250mm 28 o Page 12 of 21

15 Product data sheet Index21 AC Date: 22nd Sep 2010 Issue No: 6 Page: 2 of 2 Python Pump / Water Bath Agitator Type: Agitation type: Output: Speed: Protection: Max flow no pressure: Max min flow: Connection size: Model XX 3-stage semi - submersible Continuous 90watts 2700rpm Thermal trip 20 litres per minute 18m 15mm diameter tube Product coils Length Max Qty Short: 3.8m 12 Long: 5.4m 12 Super Long: 8.0m 8 Material: 316 stainless steel Compliance to Standards and Legislation All coolers comply with Brewers Society Code of Practice for Electrical Safety in Beer Dispense in License Premises. Designed to EN60335 part1 (Safety of Household and Similar Electrical Appliances-General Requirements). Product complies with: EMC Directive (2004/08/EC) Low Voltage directive (2006/95/EC) Machinery Directive (89/392/EEC) Page 13 of 21

16 Product data sheet Index21 WC Date: 22nd Sep 2010 Issue No: 6 Page: 1 of 2 Performance Nominal Icebank pull down:( water 10 o C at 24 o C ambient) Icebank weight: Thermal capacity icebank: Maximum ambient temperature: Model XX 5 hours (max. Icebank) 25kg Nominal 8675KJ (2000 Kcal) 38 o C Dimensions Base Unit Discharge Unit Height: 930mm 360mm Width: 570mm 460mm Depth: 600mm 280mm Weight: Unloaded 69kg 11kg Packed 70kg 12kg Operational 137kg 13.5kg Electrical Base Unit Discharge Unit Mains supply: 230v 1ph 50Hz 24v 1ph 50Hz Run current: 6.1 amps Start current: 31.0 amps Fuse: 10 amps Supply: 2m mains cable 3 pin UK Min 1.5mm 2 minimum cable from Style plug base unit (supplied by Installer) Refrigeration Compressor: Compressor starting torque: Compressor duty: (-10 o C Evap temp) Evaporator type: Condenser type: Expansion device: Refrigerant type charge: Control type: Option 1: Option 2: Option 3: Option 4: 21cc High starting torque 750 watts 12.7mm dia tube Plate Heat exchanger Capillary 3M x 1.5mm ID R134a refer rating plate Mechanical Ice bank thermostat Mechanical Incool thermostat Adjustable mechanical thermostat Electronic temperature controller Discharge Unit Heat exchanger: Fan motor: Output Speed Direction Protection Fan blade: Diameter Pitch Noise Levels: Distance (m) Level (db) 1 m 61 3 m 57 5 m 54 Aluminium fins on copper tube 12 watts 1250 rpm Clockwise shaft end Thermal trip 250mm 31 o Page 14 of 21

17 Product data sheet Index21 WC Date: 22nd Sep 2010 Issue No: 6 Page: 2 of 2 Python Pump / Water Bath Agitator Type: Agitation type: Output: Speed: Protection: Max flow no pressure: Max min flow: Connection size: Coolant System Coolant: Coolant mixture: Model XX 3-stage semi - submersible Continuous 90 watts 2700rpm Thermal trip 20 litres per minute 18m 15mm diameter tube Monopropylene Glycol 30% glycol, 70% water Coolant Pump 3 stage magnetically coupled drive, max min flow = 15m Product Coils Length Max Qty Short: 3.8m 12 Long: 5.4m 12 Super Long: 8.0m 8 Material: 316 stainless steel Other Controls Refrigeration system cut out Manual reset Compliance to Standards and Legislation All coolers comply with Brewers Society Code of Practice for Electrical Safety in Beer Dispense in License Premises. Designed to EN60335 part1 (Safety of Household and Similar Electrical Appliances-General Requirements). Product complies with: EMC Directive (2004/08/EC) Low Voltage directive (2006/95/EC) Machinery Directive (89/392/EEC) Page 15 of 21

18 7. Parts Lists and Exploded View Parts List Index21 AC - Model XX ITEM PART No. Description TOP PUMP - TOTTON TOP PUMP - MARCHMAY INSPECTION PANEL 3 2RF738A COIL BAR BLANK TANK HANDLE CONDENSER CONDENSER (see alternative view below) COMPRESSOR SET DANFOSS SC21F 3DF001A COMPRESSOR START RELAY COMPRESSOR START CAPACITOR FAN MOTOR FAN MOTOR BRACKET FAN COWL FAN BLADE THERMOSTAT - ICEBANK THERMOSTAT - VARIABLE THERMOSTAT - INNCOOL LIFTING HANDLE COIL CLAMP NEON - GREEN SOCKET FEMALE CASTOR COIL ASSY LG 9.5 x 5.0M: MAX 12 COILS COIL ASSY SH 9.5 x 3.8M: MAX 12 COILS COIL ASSY LG 9.5 x 8.0M: MAX 8 COILS 6a a Exploded View Index21 AC Model XX ALTERNATIVE CONDENSOR ARRANGEMENT Page 16 of 21

19 Page 17 of 21

20 Parts list Index 21 WC Model XX Item Part no. Description TOP PUMP - TOTTON TOP PUMP - MARCHMAY GLYCOL TANK 3 2RF378A COIL BAR BLANK TANK HANDLE 6 CM011514S ½ BSP to 15MM FITTING COMPRESSOR SET DANFOSS SC21F 3DF001A COMPRESSOR START RELAY COMPRESSOR START CAPACITOR TRANSFORMER GLYCOL PUMP TOTTON GLYCOL PUMP MARCHMAY V CONNECTOR THERMOSTAT - ICEBANK THERMOSTAT - VARIABLE THERMOSTAT - INNCOOL LIFTING HANDLE PRESSURE SWITCH PLATE HEAT EXCHANGER (Pre week ) PLATE HEAT EXCHANGER (Post week ) COIL CLAMP NEON - GREEN SOCKET FEMALE CASTOR N/s 2MC824A GLYCOL 4 LT 19 15SV BALL VALVE 15MM COIL ASSY LG 9.5 x 5.0M: MAX 12 COILS COIL ASSY SH 9.5 x 3.8M: MAX 12 COILS COIL ASSY LG 9.5 x 8.0M: MAX 8 COILS Page 18 of 21

21 Exploded View Idex21 WC Model XX Page 19 of 21

22 8. Wiring Diagram Index21 AC Model XX Page 20 of 21

23 Index21 WC Page 21 of 21

24 Page 22 of 21

REMOTE COOLER AIR COOLED & WATER COOLED

REMOTE COOLER AIR COOLED & WATER COOLED REMOTE COOLER AIR COOLED & WATER COOLED Installation & User Instructions (To be left with the user) PLEASE READ CAREFULLY BEFORE INSTALLING THE UNIT Please follow these instructions carefully. Only if

More information

Product Manual. Model Number Range XX XX

Product Manual. Model Number Range XX XX Product Manual Model Number Range 06 1 3601XX 06 1 3602XX Doc Ref: 58 0908 201 Latest rev date: 17.05.2012 Applies to Index remote cooler range: - Index21 AC, Air cooled models with part code commencing

More information

SUPER ASTRA PRODUCT MANUAL. PM R20 Issue 3 1/00

SUPER ASTRA PRODUCT MANUAL. PM R20 Issue 3 1/00 PRODUCT MAUAL PM R20 Issue 3 1/00 COTETS 1. Introduction... 1 2. Specification... 1 3. Installation... 2 4. Service Information... 3 5. User Maintenance... 3 1. ITRODUCTIO Super Astra is a compact beer

More information

Introduction to the Cornelius CRYOCOOL 100 System for Extra-cold Products and Detailed Information for Surveying, Installation and Commissioning

Introduction to the Cornelius CRYOCOOL 100 System for Extra-cold Products and Detailed Information for Surveying, Installation and Commissioning Introduction to the Cornelius CRYOCOOL 100 System for Extra-cold Products and Detailed Information for Surveying, Installation and Commissioning Issue 2 06/05/05 Contents Page The System Product Overview

More information

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ] Product Manual Viscount IV series of carbonators and chillers Part Number 3B3075 Issue 01 [16-04-07] Contents Section Page Section Page Introduction 2 Safety 2 Description 2 Schematics 4 Fault Finding

More information

CH750, CH751 & CH951 CHILLERS

CH750, CH751 & CH951 CHILLERS CH750, CH751 & CH951 CHILLERS Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com

More information

PM R34,35,38 Issue 5 7/02 PRODUCT MANUAL

PM R34,35,38 Issue 5 7/02 PRODUCT MANUAL PM R34,35,38 Issue 5 7/02 PRODUCT MANUAL CONCORD CONTENTS 1. Introduction... 1 2. Specification... 1 3. User Instructions... 2 3.1 Operation... 2 3.2 Cleaning Routine... 2 4. Installation... 3 5. Maintenance...

More information

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Remote Water Chiller, 8 GPH A9100080-A / A9100080-A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894 NOTES TO INSTALLER: 1. Please leave this

More information

Trouble Shooting Guide PWA, 3-phase (D10571)

Trouble Shooting Guide PWA, 3-phase (D10571) Trouble Shooting Guide PWA, 3-phase (D10571) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage Loose wire

More information

CHILLERS. Operator s & Installation Manual

CHILLERS. Operator s & Installation Manual CHILLERS MODELS: CH750, CH751 & CH951 Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: May 5, 2010 Revision: D Visit the IMI Cornelius web site at

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING

More information

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an

More information

Glass Door Merchandiser. Model RM-49

Glass Door Merchandiser. Model RM-49 Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT

More information

Glass Door Merchandiser

Glass Door Merchandiser Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT

More information

Vision Series Installation Manual Original instructions

Vision Series Installation Manual Original instructions Vision Series Installation Manual Original instructions English version EN Italian - IT Danish - DK Finnish - FIN Appliance types covered: Model Type 01-1000-xx Vision 5 shelf cooler 01-8300-xx Vision

More information

Glass Door Merchandiser. Model RM-45-SD

Glass Door Merchandiser. Model RM-45-SD Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT

More information

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL NEPTUNE OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the Neptune dehumidifier is a super high capacity industrial

More information

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

Trouble Shooting Guide PAA, 1-phase (D3731)

Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS AquaArctic Remote Water Chiller A9100080 -A TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894

More information

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: 32305600 OPERATION & MAINTENANCE INSTRUCTIONS 0304 Parts List Item Part No Description Qty 1 FT900001 Top Cover 1 2 FT900002 Filter

More information

INSTALLATION & SERVICE MANUAL QUANTUM SERIES

INSTALLATION & SERVICE MANUAL QUANTUM SERIES INSTALLATION & SERVICE MANUAL QUANTUM SERIES IMI CORNELIUS INC. One Cornelius Place Anoka, MN 55303 Tel: 1-888-248-5568 / 630-539-5050 Fax: 1-800-344-3801 / 630-539-6960 Part Number- 7208011206 Revision-

More information

Product Manual. Scotsman. Models: 10150, and 10250

Product Manual. Scotsman. Models: 10150, and 10250 Product Manual Scotsman Models: 10150, 10200 and 10250 IN TRO DUC TION This service manual is intended as a reference for the installer, user, and service agent of this Scotsman ice dispenser. It includes

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

Trouble Shooting Guide FAA, 3-phase (D3631)

Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

INSTALLATION, COMMISSIONING AND OPERATING MANUAL INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081305-01 Date 10/08 Introduction IOD150,IOD200,IOD250

More information

TABLE OF CONTENTS FOR YOUR SAFETY

TABLE OF CONTENTS FOR YOUR SAFETY TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...2 2. OPERATION & FUNCTION OF PARTS...2, 3 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION REQUIREMENTS...3, 4 4. INSTALLATION

More information

CH250 AND CH251 CHILLERS

CH250 AND CH251 CHILLERS CH250 AND CH251 CHILLERS Operator s & Installation Manual Release Date: April 19, 2004 Publication Number: 620914801 Revision Date: May 15, 2015 Revision: G Visit the Cornelius web site at www.cornelius.com

More information

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

TROUBLESHOOTING VANGUARD

TROUBLESHOOTING VANGUARD TROUBLESHOOTING VANGUARD IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring. WARNING: Disconnect electrical power to the Unit to prevent personal injury

More information

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service What you will learn Introduction Installation Operation Maintenance Take It Apart Diagnostics HID Ice Maker-Dispensers HID models

More information

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL BD-150 (1025000) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL BD-150 OWNERS MANUAL Page 1 of 12 INTRODUCTION Designed for a wide range of applications, the BD-150 dehumidifier is a super high capacity

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER G-Series Cooler RECHARGE COLD MERCHANDISER U.S. Patent No. 8,215,125 Instruction Manual FOR YOUR FUTURE REFERENCE This easy-to-use manual will guide you in getting the best use of your cooler. Remember

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Flat Top Bottle Cooler BC Series BC72 shown C US Form No. Z2295 Rev. 04.05.2018 JOB AREA ITEM NO. MODEL NO. BC24 SERIES BC36 SERIES BC48 SERIES BC24 shown BC72 shown BC48LT

More information

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER G-Series Cooler RCM-77 RECHARGEABLE COLD MERCHANDISER Manual is for the following model: RCM-77-N23EB U.S. Patent No. 8,215,125 Instruction Manual Manual is for the following model: RCM-77-N23EB Instruction

More information

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WWW.BREEZAIRE.COM WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling

More information

IMI CORNELIUS CHILLER

IMI CORNELIUS CHILLER IMI CORNELIUS CHILLER Service Manual Release Date: November 9, 2005 Publication Number: 620920816SER Revision Date: NA Revision: A Visit the IMI Cornelius web site at www.cornelius.com for all your Literature

More information

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250 INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250 Release Date: March 24, 2004 Publication Number: 92181INS Revision Date: April 07, 2014 Revision: G Visit the Cornelius web site at www.cornelius.com

More information

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading to insure all

More information

POWER PACK SERVICE MANUAL

POWER PACK SERVICE MANUAL POWER PACK SERVICE MANUAL MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information

CRYOCOOL Systems Product Manual. Water cooled floor standing units (WC)

CRYOCOOL Systems Product Manual. Water cooled floor standing units (WC) CRYOCOOL Systems Product Manual This manual covers the following units Air cooled floor standing units (AC) CRYOCOOL 50 CRYOCOOL 140 CRYOCOOL 165 CRYOCOOL 210 Water cooled floor standing units (WC) CRYOCOOL

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components dn0521 Page 1 of 12 INSTALLATION INSTRUCTIONS CAUTION

More information

Power Pack Service Manual

Power Pack Service Manual Power Pack Service Manual MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL KOMPACT OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the Kompact is a rugged, industrial unit, which utilizes

More information

Power Pack Service Manual

Power Pack Service Manual Power Pack Service Manual MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI NO. S051-800 ISSUED: MAR. 26, 2010 REVISED: HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B SERVICE MANUAL IMPORTANT This manual should be read carefully

More information

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER G-Series Cooler RECHARGE COLD MERCHANDISER 2 **Patent Pending** Manual is for the following models: -N13EB Instruction Manual FOR YOUR FUTURE REFERENCE This easy-to-use manual will guide you in getting

More information

POWER PACK SERVICE MANUAL

POWER PACK SERVICE MANUAL POWER PACK SERVICE MANUAL MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Glass Frosters FR Series FR48 SS shown C US Form No. Z2296 Rev. 01.16.2015 Glass Frosters Installation & Operation Manual JOB AREA ITEM NO. MODEL NO. FR24 SERIES FR36 SERIES

More information

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD60 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the CD60 dehumidifier is a rugged, industrial unit which utilizes

More information

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions INSTALLATION MANUAL Series 322 Ice Cube Machine SPECIFICATIONS 7.00 15.00 C A 6 ft electrical cord 1.00 2.00 22.00 5.00 Front 16.38 11.25 5.00 F E Air In D 2.75 2.25 14.75.75 B 23.50 21.00 Opening 23.50

More information

INSTRUCTIONS WATER CHILLERS. Active Aqua Chiller, 1/10 HP. Active Aqua Chiller, 1/4 HP. DISTRIBUTED BY

INSTRUCTIONS WATER CHILLERS. Active Aqua Chiller, 1/10 HP. Active Aqua Chiller, 1/4 HP.  DISTRIBUTED BY WATER CHILLERS Active Aqua Chiller, 1/10 HP Active Aqua Chiller, 1/4 HP DISTRIBUTED BY CHILLER 1/10 HP (13-50 GALLON) Control box Circuit board Back cover of circuit board Top cover Water inlet & outlet

More information

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO--175 8 VALVE Release Date: March 24, 2004 Publication Number: 620917902INS Revision Date: April 08, 2014 Revision: E Visit the Cornelius web site

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER G-Series Cooler RCM-2 RECHARGE COLD MERCHANDISER 2 **Patent Pending** Manual is for the following models: RCM-2-N13EB Instruction Manual Manual is for the following models: RCM-2-N13EB Instruction Manual

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 793-0 Fax +49 (0) 793-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard warnings.

More information

INSTRUCTION MANUAL Model: SU3022

INSTRUCTION MANUAL Model: SU3022 INSTRUCTION MANUAL Model: SU3022 GUARANTEE This product is guaranteed for 2 years from the date of original purchase. If any defect arises due to faulty materials or workmanship, the unit will, either

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION

More information

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading

More information

O p e r a t i n g I n s t r u c t i o n s

O p e r a t i n g I n s t r u c t i o n s O p e r a t i n g I n s t r u c t i o n s www.masterblasterfoam.co.uk Page 1 of 10 Contents Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Introduction & Features Safety Instructions Warnings,

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Product Information and Technical Guide

Product Information and Technical Guide Product Information and Technical Guide Side by Side and Top Mount Refrigerators July 2003 - December 2003 White-Westinghouse 5995540384 January 2004 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Glass Frosters MODEL NOS. FR24 Series FR36 Series FR48 Series FR60 Series c IMPORTANT INFORMATION This manual has been prepared to assist you in the installation

More information

User and Installation Instructions. Seal Refrigerated Merchandisers

User and Installation Instructions. Seal Refrigerated Merchandisers User and Installation Instructions Seal Refrigerated Merchandisers C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100 IS517 Page 1 Dear Customer, Thank you for purchasing

More information

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER CARVER - CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER 1:0 SPECIFICATIONS Water capacity Water connections Water supply 9 litres (2 gallons)

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632

More information

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components dcn0620 Page 1 of 12 INSTALLATION INSTRUCTIONS CAUTION

More information

CHILLER. Model CH3000. Operator s & Installation Manual

CHILLER. Model CH3000. Operator s & Installation Manual CHILLER Model CH3000 Operator s & Installation Manual Release Date: February 14, 2011 Publication Number: 620054173OPR Revision Date: May 08, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com

More information

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER Instruction Manual Please read these instructions carefully before use and retain for future reference. Before switching on your

More information

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 12 CD30 PACKAGE CONTENTS Item Description Quantity 1133500 Dehumidifier 1 3014338 PVC tube 12mm I/D 3 M 3086101 Jubilee clip

More information

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 8 Product Support Questions: Contact Ebac USA at (757) 873 6800 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit

More information

Operating Instructions

Operating Instructions Operating Instructions Carbonator dry Carbonator wet Warm carbonator The appliance described here may only be used by properly trained operators and maintenance staff who have closely studied the instructions

More information

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G WINDOW TECHNICAL GUIDE Single package Cooling only and Heat pump Models YO-YM 09-24 R407C YM 09 V6 G YM 09 V7 G YO 12-19-24 V6 G YO 12-19-24 V7 G YORK List of Contents Page 1 - Safety...2 2 - Unit packaging...2

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

Power Pack Service Manual

Power Pack Service Manual Power Pack Service Manual MMPP4301-EP MMPP4301 MMPP4301-PKG MMPP4302 MMPP4302-PKG MMPP4305-PKG MMPP4301-WC MMPP4302-WC MMPP4305-PKG-WC www.micromatic.com 1 TABLE OF CONTENTS Equipment Specifications...

More information

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL Ice-O-Matic 111000 East 45th Ave Denver, Colorado 80239 Part Number 9081305-01 Rev. C Revision Date: September 19, 2011

More information

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5 Introduction The Scotsman Compact Refrigerator is a unique product, capable of being built into a cabinet because of its front vented, forced-air cooling system. It s also designed to be a companion to

More information

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure

More information

KM-61BAH KM-101BAH KM-151BAH

KM-61BAH KM-101BAH KM-151BAH NO. M006-749 ISSUED: FEB. 18, 2008 REVISED: JUN. 12, 2008 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER MODEL KM-61BAH KM-101BAH KM-151BAH SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt

More information

Portable Refrigerator

Portable Refrigerator Portable Refrigerator Owners Manual Single door 40 litre 65 litre 80 litre 125 litre Double door 74 litre 95 litre 2009 Introduction The National Luna range of portable fridges and freezers are high-performance,

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODEL: CFF-500 Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: May 10, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F CFF-500 CHILLER Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com for

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

Glass Door Refrigerators

Glass Door Refrigerators To better help you obtain assistance or service should you ever need it, write down the following information about the product. This information is on the identification label located on the left hand

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

Siberian Elite Glycol Chiller 230V / 50Hz Installation, Operation & Service Manual

Siberian Elite Glycol Chiller 230V / 50Hz Installation, Operation & Service Manual Siberian Elite Glycol Chiller 230V / 50Hz Installation, Operation & Service Manual lancerbeverage.com Table of contents 1. Introduction... 3 2. The Company... 3 3. Our Products... 3 4. Product Details...

More information