VENT SYSTEM COMPONENTS

Size: px
Start display at page:

Download "VENT SYSTEM COMPONENTS"

Transcription

1 Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances Standard kit lengths of 25' and 35' Large 24 x24 flashing base Lifetime warranty HVAC No. MFG Part No. Size Length Price SLK ' $ SLK ' $1, SLK ' $1, SLK ' $1, SLK ' $1, SLK ' $1, SLK ' $1, SLK ' $1, Kits include flexible length, round top, flashing, mortar guard Standard kit lengths of 15', 25' and 35' Pull-downs stretch and lead the flexi-liner down the chimney Liner Material Aluminum 3003, 2-ply (0.00each) Maximum Flue Gas Temperature 470 F Stretch Ratio 5:1 (approximate) Clearances 0" between liner and chimney interior 0" between combustible materials and chimney exterior Liner listed to UL1777 and ULC-S635 Compatible with Type B gas vent systems Lifetime warranty HVAC No. MFG Part No. Size Length Price ALK ' $ ALK ' $ ALK ' $ ALK ' $ ALK ' $ ALK ' $ ALK35 5-1/2 35' $ ALK ' $ ALK ' $ ALK ' $ ALK ' $ ALK ' $ Aluminum Extension Kits - Gas 10' flexible liner length Includes coupler and fastener package UL-listed HVAC No. MFG Part No. Size Length Price ALKE10 5ALKE10 6ALKE10 10' 10' 10' $57.66 $72.01 $ ALKE10 10' $ ALKE10 10' $

2 Chimney Liner Kits Chimney Liner Pull-Downs Flex Connectors for ALK Liners 3FX-PD 4FX-PD 5FX-PD 6FX-PD 7FX-PD 8FX-PD $25.83 $25.83 $22.51 $24.33 $28.27 $ All Fuel Chimney Chimney Pipe Sections 3ALK-FC 4ALK-FC 5ALK-FC 6ALK-FC 7ALK-FC 8ALK-FC $12.83 $13.64 $14.63 $17.60 $18.39 $20.33 Allows for installation between 1 centers and still provides 2" clearance from combustible material Secure twist-lock design couples chimney sections together with just a 1/8 turn. Locking bands secure joints Includes locking band - sections overlap by 1 1/, 10"-1 sections overlap by 1 1/ Chimneys are sized according to the inner diameter and are available in through 1 The outside diameter is 2" larger than the inside diameter HVAC No. MFG Part No. Size Length Price TLC6 ID - OD $ TLC9 ID - OD 9" $ TLC12 ID - OD 12" $ TLC18 ID - OD 1 $ TLC24 ID - OD 2 $ TLC36 ID - OD 3 $ TLC6 ID - OD 9" $ TLC9 ID - OD 9" 9" $ TLC12 ID - OD 9" 12" $ TLC18 ID - OD 9" 1 $ TLC24 ID - OD 9" 2 $ TLC36 ID - OD 9" 3 $ TLC6 ID - OD 10" $ TLC9 ID - OD 10" 9" $ TLC12 ID - OD 10" 12" $ TLC18 ID - OD 10" 1 $ TLC24 ID - OD 10" 2 $ TLC36 ID - OD 10" 3 $

3 All Fuel Chimney All-Fuel Pipe and Accessories Rafter Radiation Shields HVAC No. MFG Part No. Description Size Price TLCCSR Ceiling Support $ TLCCSR Ceiling Support $ TLCCSR Ceiling Support $ TLCAWS Wall Support $ TLCAWS Wall Support $ TLCAWS Wall Support $ TLCRS Roof Support $ TLCRS Roof Support $ TLCRS Roof Support $ TDTR Cut-Out Trim Ring $ TDTR Cut-Out Trim Ring $ TDTR Cut-Out Trim Ring $ TDTS Stainless Starter and Cleanout Tee $ TDTS Stainless Starter and Cleanout Tee $ TDTS Stainless Starter and Cleanout Tee $ TLCSPA Stove Pipe Adaptor $ TLCSPA Stove Pipe Adaptor $ TLCSPA Stove Pipe Adaptor $82.59 Install immediately below the roof flashing, inside any enclosure TLCRRS 7TLCRRS 8TLCRRS $87.41 $75.15 $78.21 Storm Collars Use in conjunction with roof flashing to keep precipitation out Firestop Radiation Shields 6TLCSC 7TLCSC 8TLCSC $22.24 $22.64 $29.28 Required where an enclosed chimney passes from a lower living space into an upper living space Maintains the mandatory 2 clearance to combustibles Joist Shield is used in floor/ceiling penetrations, other than those that include a ceiling support Joist Shield not required when passing through roof TLCFRS 7TLCFRS $31.44 $ TLCFRS $34.74 Adjustable Roof Flashing Kits, 0 to 6/12 Pitch Galvalume Includes storm collar All seams are sealed with silicone sealant TLCF6 7TLCF6 8TLCF6 $ $ $

4 All Fuel Chimney Adjustable Ceiling Plate Adapts to multiple roof pitches Matte black finish TLCACPT 7TLCACPT 8TLCACPT Adjustable Roof Flashing Kits, 6/12 to 12/12 Pitch $81.66 $ $ Galvalume Includes storm collar All seams are sealed with silicone sealant Tall Cone Flashing, 0/12 to 2/12 Pitch Wall Bands 6TLCF12 7TLCF12 8TLCF12 $99.86 $ $ Galvalume Includes storm collar All seams are sealed with silicone sealant TLCFF 7TLCFF 8TLCFF $ $ $ Stainless steel construction Maintains the mandatory 2 clearance to combustibles Used above the tee, then every 8' thereafter Stovepipe Adaptors 6TLCWB 7TLCWB 8TLCWB $50.23 $60.83 $65.71 Twist-lock for easy connection Use for quick and easy transition from black stovepipe to factory-built chimney TLCSPA 7TLCSPA 8TLCSPA $48.86 $48.11 $

5 All Fuel Chimney Insulated Elbow Kits Rain Caps Elbows can be rotated to attain optimum offset and allow chimney to return to vertical before installing locking bands. May not be used outdoors. Elbow kits include: 2 elbows (Exception: 12" and 1 sizes include four 15 elbows assembled into two 30 elbows) 2 locking bands (Exception: 10", 12" and 1 sizes include four locking bands) 1 elbow support All hardware Must be used with all offset installations and will support 15' of chimney HVAC No. MFG Part No. Description Size Price TLCEK15 15 Degree $ TLCEK30 30 Degree $ TLCEK15 15 Degree $ TLCEK30 30 Degree $ TLCEK15 15 Degree $ TLCEK30 30 Degree $ Twist lock connection Premium quality stainless steel designed for use in the elements Adjustable Wall Supports 6TLCC 7TLCC 8TLCC $ $ $ Includes top plate, side brackets, hardware, non-twist-lock insulated tee cap, and a long L-bracket Support between 30 feet and 74 feet of chimney, based on size and orientation Insulated Tees with Tee Caps 6TLCAWS 7TLCAWS 8TLCAWS $ $ $ Two locking bands Uninsulated(single-wall) twist-lock tee cap for non-wall support applications only Attic Insulation Shields 6TLCT 7TLCT 8TLCT $ $ $ Not to be used for enclosed chimneys passing through attic For that application, use firestop radiation shield and rafter radiation shield TLCIS 7TLCIS 8TLCIS $ $ $

6 All Fuel Chimney Cathedral Ceiling Support Boxes Supports a total of 38' of chimney with up to 15 feet below support Includes support clamp, allowing chimney pipe to pass below support Also acts as a firestop with use of trim plate 12/12 maximum pitch Shielding Insulation Wrap 6TLCCSS 7TLCCSS $71.92 $ TLCCSS $ TLCSI 12" x 4 x 2" $

7 B-Vent Pipe and Accessories Round Pipes to 12" pipe/fitting couplers overlap 1-3/ when joined together, assembled length is 1-3/ less than listed length The allowable minimum clearance to combustibles is 1" Outside Diameter (OD) for sizes through is size plus 1/2" Outside Diameter (OD) for sizes through 12" is size plus 1" HVAC No. MFG Part No. Size Listed Length Price RP6 3RP12 12" $18.33 $ RP18 1 $ RP24 2 $ RP36 3 $ RP48 4 $ RP60 60" $ RP6 $ RP12 12" $ RP18 1 $ RP24 2 $ RP36 3 $ RP48 4 $ RP60 60" $ RP6 $ RP12 12" $ RP18 1 $ RP24 2 $ RP36 3 $ RP48 4 $ RP60 60" $ RP6 $ RP12 12" $ RP18 1 $ RP24 2 $ RP48 4 $ RP60 60" $ RP12 12" $ RP18 1 $ RP24 2 $ RP36 3 $ RP48 4 $ RP60 60" $ RP12 12" $ RP18 1 $ RP24 2 $ RP36 3 $ RP48 4 $ RP60 60" $ RP18 10" 1 $ RP24 10" 2 $ RP36 10" 3 $ RP18 12" 1 $ RP24 12" 2 $ RP36 12" 3 $

8 B-Vent Pipe and Accessories Male Adaptors Transitions from all brands of listed Type B Gas Vent to ALK Liner Female Adaptors 3RAA 4RAA 5RAA 6RAA 7RAA $25.32 $24.88 $27.10 $29.52 $ RAA $55.44 Adapts vent to other brands of B vent Female B-Vent Adaptors 3RRA 4RRA 5RRA 6RRA $36.08 $37.03 $39.03 $ Roof Caps, 7-1/2" OD Increasers 3RLA 5RLA 6RLA 7RLA 8RLA $20.39 $26.33 $27.96 $48.47 $53.97 Designed to resist entry of birds RM 8RM 10RM 12RM 10" 12" $60.15 $79.07 $ $ RN4 3RN5 4RN5 4RN6 4RN7 5RN6 to to to to to to $33.97 $39.01 $35.90 $37.82 $91.34 $ RN7 to $ RN7 to $ RN8 to $ RN8 to $ RN10 to 10" $

9 B-Vent Pipe and Accessories High Wind Caps Designed to resist nesting birds Exceptional performance in windy conditions Adjustable Elbows 3RHW 4RHW 5RHW 6RHW $26.60 $26.22 $37.27 $42.22 HVAC No. MFG Part No. Description Size Price Adjustable Length Pipes 3REA60 3REA90 4REA60 4REA90 5REA60 5REA90 45 and 60 Degree 90 Degree 45 and 60 Degree 90 Degree 45 and 60 Degree 90 Degree $27.28 $40.96 $31.81 $50.93 $35.49 $ REA60 45 and 60 Degree $ REA90 90 Degree $ REA45 45 Degree $ REA90 90 Degree $ REA45 45 Degree $ REA90 90 Degree $ REA45 45 Degree 10" $ REA45 45 Degree 12" $ Overlap minimum: 1 Overlap maximum (12 length): 10 Overlap maximum (18 length): 16 HVAC No. MFG Part No. Size Listed Length Price Firestop Spacers 3RPA 4RPA 5RPA 12" 12" 12" $20.22 $23.17 $ RPA 12" $ RPA 1 $ RPA 1 $ RPA 10" 1 $ RPA 12" 1 $ Fits 2 x6 wall Available in 4 only RFS $

10 B-Vent Pipe and Accessories Wall Thimbles Wall Brackets Provides necessary clearance to combustibles Sleeve is adjustable from 3 to RWT 4RWT 5RWT 6RWT $24.40 $25.30 $26.88 $ RWT $ RWT $86.64 through 12" bracket used with perforated pipe strap (supplied by others) RWB 4RWB 5RWB 6RWB 7RWB $16.54 $14.67 $16.48 $16.54 $ RWB $ RWB 10" $ RWB 12" $ RWB 1 $18.99 Adjustable Roof Flashing, 0 to 6/12 Pitch RF 4RF 5RF 6RF 7RF 8RF $19.18 $19.21 $28.12 $43.52 $52.36 $ RF 10" $ RF 12" $ RF 1 $ Adjustable Roof Flashing, 6/12 to 12/12 Pitch RFA 4RFA 5RFA 6RFA 7RFA 8RFA $46.64 $48.40 $49.81 $63.84 $ $

11 B-Vent Pipe and Accessories Tall Cone Roof Flashings Support Assemblies Storm Collars 3RTF 4RTF 5RTF 6RTF 7RTF 8RTF $34.94 $39.03 $45.69 $56.06 $67.41 $ RTF 10" $ RTF 12" $ RTF 1 $ Supports 30' of pipe Acts as a firestop RSA 4RSA 5RSA 6RSA $36.15 $26.14 $29.00 $ RSA $ RSA $ RSA 10" $ RSA 12" $ RSA 1 $ Adjustable Storm Collars 3RS 4RS 5RS 6RS 7RS 8RS $4.71 $4.71 $10.58 $11.24 $14.45 $ RS 10" $ RS 12" $ RS 1 $56.56 Designed to be snug around vent pipe for a weather-tight fit For use with roof flashing and caulk SC 1 $37.36 Pipe Collars Covers rough openings RPC 4RPC 5RPC 6RPC 7RPC $7.90 $7.90 $8.93 $10.03 $ RPC $

12 B-Vent Pipe and Accessories Gripper Supports Tee Caps Supports 30' of pipe Acts as a firestop RGS 4RGS 5RGS 6RGS $24.88 $29.94 $34.85 $ Draft Hood Connectors Tees Wyes 3RTC 4RTC 5RTC 6RTC 7RTC 8RTC $6.05 $6.05 $7.90 $8.29 $15.69 $ RTC 10" $ RTC 12" $ RTC 1 $ RDH 4RDH 5RDH 6RDH 7RDH 8RDH $14.85 $16.94 $18.35 $18.92 $30.03 $ RDH 10" $ RDH 12" $ RDH 1 $ RT3 4RT4 5RT3 5RT5 6RT6 7RT7 x x x x x x x x x x x x $49.79 $56.58 $67.23 $67.23 $75.88 $ RT8 x x $ RT10 10" x 10" x 10" $ RT12 12" x 12" x 12" $ RT 1 x 1 x 1 $ RYF43 6RYF43 x x x x $99.59 $

13 B-Vent Pipe and Accessories Support Plates Supports 30' of pipe SP 1 $85.07 Tjernlund Products Controls Duct Boosters HVAC No. MFG Part No. Description Price PS2501 PS-1505 SC1 UC-1 MAC-1E MAC-4E Adjustable Pressurestat with Differential Air Switch Fan Proving Switch for AutoDraft Inducers Speed Control for Duct Booster UC1 Universal Interlock Control Multiple Appliance Control, For UC-1, Adds One Appliance Multiple Appliance Control, For UC-1, Adds Up to Four Appliances $ $ $ $ $ $ HVAC No. MFG Part No. Description Price EF-6 EF-8 Duct Booster Fan, 120V-30 Watt-.40A Duct Booster Fan, 120V-56 Watt-1.1A $ $ Inline Draft Inducers HVAC No. MFG Part No. Fits Duct Diameters Max MBH Input Price DJ-3 D-3 I IL XL HD Side Shot Venter for Oil Heaters,,,,,,, 9", 10" 12" 10", 12", 1, 1 1, 1, 20" 20", 2 HVAC No. MFG Part No. Capacity Natural and LP Gas Flame Retention Oil Burner Price SS1 SS MBH MBH MBH MBH $ $ $1, $1, $2, $9, $2, $1, Vent Hoods HVAC No. MFG Part No. Description Price VH-1-3 VH-1-4 VH-1-6 VH-1-8 VH-1-10 Side Wall Vent Hood, Side Wall Vent Hood, Side Wall Vent Hood, Side Wall Vent Hood, Side Wall Vent Hood, 10" $ $ $ $ $

14 Tjernlund Products Sidewall Vent System, Vent Pipe Diameter HVAC No. MFG Part No. Max MBH Input Price GPAK-1T-HTPV GPAK-JT-HTPV $1, $1, Power Venters HVAC No. MFG Part No. Description Price Water Heater Vent HSJ HS-1 HS-2 HS-3 HS-4 HS-5 Power Venter, Fits Power Venter, Fits and Power Venter, Fits and Power Venter, Fits and 10" Power Venter, Fits,, 10" and 12" Power Venter, Fits, 10", 12" and 1 $ $ $1, $ $2, $3, HVAC No. MFG Part No. Description Price WHK-I Power Venter Interlock Kit for Water or Pool Heaters $ Field Controls Barometric Draft Control Type MG1 dual acting barometric dampers available from 4-9 Type M+MG2 dual acting barometric dampers available from HVAC No. MFG Part No. Size Action Suitable For Price Field Accessory Items 5RC 6RC 6MG1 7RC Single Acting Single Acting Double Acting Single Acting Oil, Wood, Coal Oil, Wood, Coal Gas Oil, Wood, Coal $75.15 $69.54 $ $ MG1 Double Acting Gas $ MG1 Double Acting Gas $ RC Single Acting Oil, Wood, Coal $ RC 9" Single Acting Oil, Wood, Coal $ M+MG2 10" Triple Acting Oil, Wood, Coal, Gas $ M+MG2 12" Triple Acting Oil, Wood, Coal, Gas $ M+MG2 1 Triple Acting Oil, Wood, Coal, Gas $ M+MG2 1 Triple Acting Oil, Wood, Coal, Gas $ M+MG2 1 Triple Acting Oil, Wood, Coal, Gas $1, M+MG2 20" Triple Acting Oil, Wood, Coal, Gas $1, M+MG2 2 Triple Acting Oil, Wood, Coal, Gas $1, M+MG2 2 Triple Acting Oil, Wood, Coal, Gas $2, M+MG2 32" Triple Acting Oil, Wood, Coal, Gas $2, HVAC No. MFG Part No. Description Price GSK-3 Float Switch, 72" Leads Gas Spillage Sensing Switch, 24 VAC $20.22 $

15 Field Controls Power Venter $1, Vent Damper HVAC No. MFG Part No. Size Notes Price " Harness Not Included Harness Not Included Harness Not Included Harness Not Included Harness Not Included Harness Not Included $ $ $ $ $ $ Vent Damper Harness, Fits All Sizes $

16 Gas Chimney Liner Sizing Guide 272

17 Gas Chimney Liner Sizing Guide 273

18 Gas Chimney Liner Sizing Guide 274

PelletVent Multi-fuel venting system. UL 641.

PelletVent Multi-fuel venting system. UL 641. PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials

More information

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet

More information

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation

More information

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

Pellet Stove. Flex Pipe. Appliance Connector

Pellet Stove. Flex Pipe. Appliance Connector Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel

More information

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA

More information

Installation Instructions

Installation Instructions Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS

More information

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

5x 8 DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION 5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION These instructions apply to the Simpson Dura-Vent 5"x 8" Direct Vent System. This venting

More information

Mitchell Metal Products, Inc.

Mitchell Metal Products, Inc. Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

BDM Direct Vent systems are for use with direct vent gas fired appliances.

BDM Direct Vent systems are for use with direct vent gas fired appliances. INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.

More information

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629. DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

VP Pellet Pipe. For pellet burning stoves. FEATURES

VP Pellet Pipe. For pellet burning stoves. FEATURES CATALOG VP Pellet Pipe For pellet burning stoves. Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. FEATURES Available in 3"

More information

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4 GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications

More information

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY. CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS Selkirk LLC Selkirk LLC Research & Development State Route 93 North & Sutton Road P.O. Box 631 Logan, OH 43138 9/21/2006 TO: Our Valued Customers FROM: Glen Edgar Director R&D SUBJECT: SELKIRK MODEL DT

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS DISTRIBUTED BY: SBI VENTING DIVISION 2100 insulated chimney All-Fuel Chimney System INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIRSPACES)

More information

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent

More information

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC

More information

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal

More information

MODEL CF CEILING SUPPORTED CHIMNEY

MODEL CF CEILING SUPPORTED CHIMNEY Manufactured by Selkirk Canada Corp. - Hamilton, Ontario Installation Instructions for MODEL CF CEILING SUPPORTED CHIMNEY Round Top Storm Collar Flashing Attic Insulation Shield/Firestop Spacer Intermediate

More information

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y ii PelletVent Pro For Stoves Burning Pellets & Corn Simpson

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Tjernlund Side Wall Venting Products

Tjernlund Side Wall Venting Products Tjernlund Side Wall Venting Products Any non-condensing gas or oil fired heater that can be vented by natural draft can be Side Wall Vented with a Tjernlund Power Venter. Power Venters are available in

More information

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions Shasta Vent Inc All-Fuel HT Chimney Installation Instructions August 2015 v1.02 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.

More information

Ventis Direct Vent. Installation Instructions

Ventis Direct Vent. Installation Instructions entis Direct ent Installation Instructions A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES), TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPRORTANCE THAT

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS

More information

CHIMNEYS AND VENTS CHAPTER 8

CHIMNEYS AND VENTS CHAPTER 8 CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10 Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)

More information

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX flexible venting simply perfect cost efficient convenient durable Est. 1990 FLEX FREEDOM VENTING Introduction Freedom Flex Venting systems are top of the line when it comes to materials, cost efficiency

More information

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Installation Instructions Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y A MAJOR CAUSE OF VENT RELATED

More information

24 VAC SYSTEM CONTROL KIT

24 VAC SYSTEM CONTROL KIT 24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas draft induced appliances with a 24 VAC Gas Valve and a 30-millivolt

More information

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40 TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a

More information

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness Venting Vent Material This unit is approved for installation using 4 x 6-5/8 in co-axial direct vent pipe and accessories manufactured by Simpson Dura-Vent. Follow the installation instructions supplied

More information

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. Malm Fireplaces, Inc. 368 Yolanda Avenue - Santa Rosa, Ca 95404 (707) 523-7755 - Fax: (707) 571-8036 info@malmfireplaces.com 34 Zircon Direct Vent Tested & Listed by LabTest Certified for use in USA &

More information

Pellet Vent INSTALLATION INSTRUCTIONS

Pellet Vent INSTALLATION INSTRUCTIONS Pellet Vent INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS PELLET

More information

Type B Gas Vent. Installation Instructions

Type B Gas Vent. Installation Instructions Installation Instructions Round and Oval Type B GasVent Systems for use with natural as or liquid propane category I and draft hood equipped appliances and appliances listed to use Type B Gas Vent. Type

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II

More information

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to

More information

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...

More information

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw) H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74

More information

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw) H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74

More information

Twin Wall Installation Instructions And Maintenance Guide

Twin Wall Installation Instructions And Maintenance Guide Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate

More information

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.

More information

Ultimate Pellet Pipe

Ultimate Pellet Pipe INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS

More information

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIC is a listed venting system designed for venting commercial and industrial appliances, condensing appliances,

More information

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel

More information

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for

More information

X-593 SOLID FUEL HEATING QUESTIONNAIRE

X-593 SOLID FUEL HEATING QUESTIONNAIRE X-593 SOLID FUEL HEATING QUESTIONNAIRE CLEAR PHOTOGRAPHS & QUESTIONNAIRE REQUIRED FOR EACH INSTALLATION (UNITS & VENTS) NAME ADDRESS PHONE NO POLICY NO BROKER INSPECTED BY DATE GENERAL INSTALLATION QUESTIONS

More information

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro Installation Instructions Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4 GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3 venting Special gas vent system vent and combustion air supplement for 3 diameter venting. The following manufacturers AL29-4C Stainless Steel

More information

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Vertical Termination Part No: 3CGRVT 16 7/8 18 Vent Pipe Extension Part No: 3CG18 9 7/8 Wall Hanger Part No: 3CGWH 7 7/8 7 3/8 Corr/Guard Direct Vent Water Heater Vent/Air Intake System Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installation must meet all state and

More information

SEPARATED COMBUSTION. General WARNING

SEPARATED COMBUSTION. General WARNING Form I-UD-V-SC (09-17) Obsoletes Form I-UD-V-SC (Version 05-17) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Combustion Air Inlet / Vent Terminal Options CC6 and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FACTORY BUILT CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009. SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for

More information

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system CTLOG Direct Vent System for PELLET STOVES Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system Direct-Temp for pellet stoves is the revolutionary, high-performance

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II

More information

NovaVent. Dimensional Data

NovaVent. Dimensional Data NovaVent Dimensional Data NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired

More information

DURAVENT POLYPRO VENTING PRODUCTS

DURAVENT POLYPRO VENTING PRODUCTS DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12

More information

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro Installation Instructions Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain

More information

St. Croix Greenfield Installation Manual

St. Croix Greenfield Installation Manual St. Croix Greenfield Installation Manual Table of Contents General Information... 1 Installation Check List... 2 Approved Installations... 3 Exhaust Venting... 4 Venting - Approved Materials... 4 Venting-Typical

More information

ZC Kit AGP Pellet Insert

ZC Kit AGP Pellet Insert ZC Kit AGP Pellet Insert Compatibility AGP Pellet Insert Lopi AGP Pellet Insert Overview Packing List ZC Can Rear Panel ZC Can Top/Side Panel Bottom Panel (Fiber Board with Steel) (40) # 8 x 3/8 Type A

More information

SOUTHWEST FIREBIRD MFG Sonoran Model 36ST, 42ST

SOUTHWEST FIREBIRD MFG Sonoran Model 36ST, 42ST SOUTHWEST FIREBIRD MFG Sonoran Model 36ST, 42ST September 2008 INSTALLATION INSTRUCTIONS PREFABRICATED MODULAR MASONRY- WOOD-BURNING FIREPLACE SEE THROUGH FIREPLACE U.S. Patent Pending SAVE THIS BOOK This

More information

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD General APPLIES TO: Standard Power Vent, Fan Type Unit Heaters: Model UDAP & Model APD Standard Power Vent, Blower Type Unit Heaters: Model UDBP Form I-UD&APD Series-V-PV (05-17) Obsoletes I-UD&APD Series-V-PV

More information

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent Installation and Maintenance Instructions Saf-T Vent CI Plus Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent For Venting Commercial & Industrial Appliances Condensing Appliances Category

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible

More information

GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3" venting

GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3 venting GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting. The following manufacturers AL29-4C Stainless Steel

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

POWER VENTER. Model: PVE Series

POWER VENTER. Model: PVE Series POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power

More information

SEPARATED COMBUSTION. General

SEPARATED COMBUSTION. General Form I-UD-V-SC (Version D) Obsoletes Form I-UD-V-SC (Version C) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Inlet / Vent Terminal Options CC6 and CC2 General This

More information

VERTICAL POWER VENT KIT

VERTICAL POWER VENT KIT INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13 Chimney Solutions INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE

More information

Installation Instructions

Installation Instructions Residential Gas Furnaces Installation Instructions *RA Full Size Series 80+ High Efficiency Upflow/Horizontal *RK Full Size Series 80+ High Efficiency Downflow *RA 80+ Upflow/Horizontal *RK 80+ Downflow!

More information

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR SKU Descrpition List

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR SKU Descrpition List 3" Pipe and Fittings GV36 3"x6" B VENT PIPE $12.44 GV312 3"x12" B VENT PIPE $11.13 GV318 3"x18" B VENT PIPE $14.40 GV324 3"x24" B VENT PIPE $17.89 GV336 3"x36" B VENT PIPE $23.09 GV348 3"x48" B VENT PIPE

More information

SEPARATED COMBUSTION WARNING

SEPARATED COMBUSTION WARNING CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Form I-SDH-V (Version.5) Obsoletes I-SDH-V (Version.4) Vent Installation Applies to: Venting Requirements for PREEVA Separated-Combustion

More information

Saf-T Vent SC Plus/SC 316

Saf-T Vent SC Plus/SC 316 Installation and Maintenance Instructions Saf-T Vent SC Plus/SC 316 Double Wall One Inch Air Space Special Gas Vent For Venting Residential and Light Commercial Appliances Category I,II,III,IV Appliances

More information

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS OIL FIRED WATER HEATER INSTALLATION AND OPERATING INSTRUCTIONS Read these instructions thoroughly before starting INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS These instructions apply

More information

This firebox meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions.

This firebox meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions. 36" See Through Smooth Face wood burning fireplace OWNER S INSTALLATION MANUAL 368STM with Brushed Brass Finish Doors 368STM-1 with Platinum Finish Doors Includes Combustion Air Kit and Bi-Fold Doors CPFS

More information

Direct Exhaust Venting Kit Instructions

Direct Exhaust Venting Kit Instructions CONDENSING GAS BOILER 220/299/300/399 Direct Exhaust Venting Kit Instructions Evergreen 220/299/300/399 Kit part number 383-500-769 STOP! Read before proceeding Hazard definitions The following defined

More information

Detroit Radiant Products Co.

Detroit Radiant Products Co. UH and FA Series Concentric Vent Kit Instruction Sheet Detroit Radiant Products Co. CVK-3, 4 or 6 Concentric Vent Kit Installation Instructions This instruction sheet is intended to describe the installation

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

INSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4

INSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 P Rev. C 06/2014 INSTALLATION INSTRUCTIONS FOR PIPE REDUCER AND ALL ASSOCIATED SV4 (4") SECURE VENT/DIRECT VENT COMPONENTS INCLUDING SV4CGV-1 VERTICAL

More information

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL SWB4I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL The SWB4I fireplace is an insulated radiant wood burning fireplace with a 6-inch wide front opening. It comes

More information

FasNSeal. Installation Instructions

FasNSeal. Installation Instructions Installation Instructions FasNSeal & FasNSeal W2 Single-wall and Double-wall special gas vent FasNSeal Flex Flexible chimney liner for special gas vent for Category II, III, and IV appliances FasNSeal

More information

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible

More information

Technical and Dimensional Data. Saf-T Vent SC Plus

Technical and Dimensional Data. Saf-T Vent SC Plus Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances

More information

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT

More information