SMART 5000 Wi-Fi Touchscreen Programmable Thermostat Owners Manual

Size: px
Start display at page:

Download "SMART 5000 Wi-Fi Touchscreen Programmable Thermostat Owners Manual"

Transcription

1 by Uni-Line SMART 5000 Wi-Fi Touchscreen Programmable Thermostat Owners Manual Robertshaw 4/

2 IMPORTANT SAFETY INFORMATION WARNING: ELECTRICAL SHOCK HAZARD Turn off power at the main power source by unscrewing fuse or switching circuit breaker to the OFF position before installing, removing, or cleaning this thermostat. WARNING: FIRE AND ELECTRIC SHOCK HAZARD This device should be installed by a qualified service technician with due regard for safety as improper installation could result in a fire and electric shock hazard. WARNING: FIRE AND ELECTRICAL SHOCK HAZARD This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC. Do not switch system to cool if the temperature is below 50 F (10 C). This can damage your cooling system and may cause personal injury. Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty. Do not connect ground to any terminal in this unit. All wiring must conform to local and national building and electrical codes and ordinances. Use this thermostat only as described in the manual. 2

3 Table of Contents Application 4 Features 5 Installation 6 Wiring 14 Power The Thermostat 31 Installer Set-up 33 Operation 43 Programming 60 Specifications 64 Troubleshooting 65 Warranty 70 Thank you for purchasing a SmartSense thermostat by Uni-Line. The SMART 5000 is a multi-function thermostat. If properly installed, your SMART 5000 thermostat will provide you with many years of trouble free comfort. The SMART 5000 has been built to be an attractive, highly reliable and an easy to use thermostat. By taking the time to read and understand these simple instructions, you can take advantage of this premium product s capabilities. 3

4 APPLICATION The SmartSense SMART 5000 Wi-Fi touchscreen programmable thermostat is a 7-Day programmable thermostat that provides universal system compatibility, precise comfort control, and is easy to program. The SMART 5000 provides temperature control for gas, oil, electric, and heat pumps for up to 3 heat/2 cool systems. Above all, you can remotely monitor and control the heating and cooling system in your home or business. You can stay connected to your comfort system wherever you go. 4

5 FEATURES Large, clear display with backlight shows temperature, set temperature and humidity in the dark Menu-driven programming make set-up effortless Beautiful ergonomic design is smart and sophisticated to match your customer lifestyle Touchscreen interaction Connect to the Internet to monitor and control your heating/cooling system Compressor protection 5

6 INSTALLATION 1. Read these instructions carefully. Failure to follow the instructions can damage the product or cause a hazardous condition. 2. Check the ratings in these instructions to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After completing the installation, use these instructions to check out the product operation. Selecting The Proper Location Install the thermostat about 5 feet (1.5m), above the floor in an area with good air circulation at average temperature. See Figure 4. Do not install the thermostat where it can be affected by: Drafts or dead spots behind doors and in corners Hot or cold air from ducts Radiant heat from sun or appliances concealed pipes and chimneys Unheated or uncooled areas such as an outside wall behind the thermostat 6

7 Mounting Mounts directly on the wall in the living space using mounting screws and anchors provided. Dimensions 1. SMART 5000 dimensions: see Figure SMART 5000 back case: see Figure SMART 5000 cover plate see Figure 3. 7

8 Figure 1. Dimensions in inches (mm) 8

9 Figure 2. Back case dimensions in inches (mm) 9

10 Figure 3. Cover plate dimensions in inches (mm) 10

11 Figure 4. Selecting thermostat location 11

12 Installing Wall Plate CAUTION Electrical hazard can cause electrical shock or equipment damage. Disconnect power before wiring. The thermostat should be mounted horizontally on the wall. 1. Position and level the wall plate (for appearance only). 2. Use a pencil to mark the mounting holes. 3. Remove the wall plate from the wall and if drywall, drill two holes in the wall as marked. For firmer material such as plaster, drill two holes. Gently tap anchors (provided) into the drilled holes until flush with the wall. 4. Position the wall plate over the holes, pulling wires through the wiring opening. See Figure Insert the mounting screws into the holes and tighten. 12

13 Figure 5. Mounting wall plate 13

14 WIRING All wiring must comply with local electrical codes and ordinances. 1. See Table 1 and Figure 6 for terminal designation descriptions. Insert wires in the terminal block under the loosened screw. See Figure Securely tighten each screw. 3. Push excess wire back into the hole. 4. Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat. 14

15 Table 1. Terminal Designation Descriptions Terminal Designation RC (see Note 1) R (see Note 1) C (see Note 2) Y G Y2 O/B/W (see Note 3) AUX/W2 E L (see Note 4) Description Power for cooling--connect to secondary side of cooling system transformer Power for heating--connect to secondary side of heating system transformer Common wire from secondary side of cooling system transformer Compressor Fan relay Second stage cooling Changeover valve for heat pump systems or heat relay Auxiliary heat relay for heat pump systems or second stage heat relay Emergency heat relay for heat pump systems Equipment monitor for heat pump systems 15

16 Notes: 1. When used in a single-transformer system, leave metal jumper wire in place between RC and R. If used on a two-transformer system, remove metal jumper wire between RC and R. 2. Common wire is optional when thermostat is used with batteries. 3. If thermostat is configured for a heat pump system, configure changeover valve for cool or heat. 4. L terminal is an input port for the system monitor. Figure 6. Terminal identifications for system 16

17 Figure 7. Inserting wires in terminal block IMPORTANT: Use 18 gauge thermostat wire. 17

18 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. Figure 8. Typical hookup of conventional single-stage heat and cool system with single transformer (1H/1C conventional) 18

19 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. REMOVE FACTORY INSTALLED JUMPER. Figure 9. Typical hookup of conventional single-stage heat and cool system (1H/1C conventional) 19

20 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. Figure 10. Typical hookup of heat-only system (1 H conventional) 20

21 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. Figure 11. Typical hookup of heat-only system with fan (1 H conventional) 21

22 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. Figure 12. Typical hookup of heat-only power to open and power to close zone valve system 22

23 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. Figure 13. Typical hookup of heat-only system with normally open zone valves 23

24 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. Figure 14. Typical hookup of cool-only system (1C conventional) 24

25 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. Figure 15. Typical hookup of conventional multi-stage two-stage heating and two-stage cooling in a single-transformer system (2H/2C, 2H/1C or 1H/2C conventional) 25

26 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. REMOVE FACTORY INSTALLED JUMPER. Figure 16. Typical hookup of conventional multi-stage two-stage heating and two-stage cooling in a two-transformer system (2H/2C, 2H/1C or 1H/2C conventional) 26

27 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. 3. O/B TERMINAL SET TO CONTROL AS EITHER O OR B IN THE INSTALLER SET-UP. Figure 17. Typical hookup of single-stage heat pump with no auxiliary/back-up heat (1H/1C heat pump) 27

28 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. 3. MUST CONNECT THE 24V AC COMMON WHEN USING L. THE TERMINAL IS SHOWN AS EQUIPMENT MONITOR. 4. O/B TERMINAL SET TO CONTROL AS EITHER O OR B IN THE INSTALLER SET-UP. Figure 18. Typical hookup of multi-stage heat pump with no auxiliary/back-up heat (2H/2C heat pump) 28

29 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. 3. MUST CONNECT THE 24V AC COMMON WHEN USING L. THE TERMINAL IS SHOWN AS EQUIPMENT MONITOR. 4. O/B TERMINAL SET TO CONTROL AS EITHER O OR B IN THE INSTALLER SET-UP. Figure 19. Typical hookup of single-stage heat pump with auxiliary/back-up heat (2H/1C heat pump) 29

30 1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2. FACTORY INSTALLED JUMPER. 3. MUST CONNECT THE 24V AC COMMON WHEN USING L. THE TERMINAL IS SHOWN AS EQUIPMENT MONITOR. 4. O/B TERMINAL SET TO CONTROL AS EITHER O OR B IN THE INSTALLER SET-UP. Figure 20. Typical hookup of multi-stage heat pump with auxiliary/back-up heat (3H/2C heat pump) 30

31 POWER THE THERMOSTAT Wiring 24V AC Common Single-Transformer System: Connect the common side of the transformer to the C screw terminal of the thermostat wall plate. Leave the metal jumper wire in place between RC and R. Common wire is optional when thermostat is used with batteries. Two-Transformer System: Connect the common side of the cooling transformer to the C screw terminal of the thermostat wall plate. Remove the metal jumper wire between RC and R. Mount Thermostat to Wall Plate Align the terminal screw blocks with the pins on the back of the thermostat. Push the thermostat straight onto the wall plate until it snaps into place. See Figure

32 Figure 21. Mount thermostat to wall plate 32

33 INSTALLER SET-UP Follow these steps to enter the Installer Set-up: 1. See Figure Press and release the Key. System mode will blink, then Press and hold the key for approximately 5 seconds until the screen changes. The menu number will display at the bottom right corner. See Figure Figure 22-1 Figure

34 2. Press the or key to display the submenu, and then press the key to enter the submenu. Under submenu, use the or key to set the parameters. See Figure 22-3 and Figure Press the key to exit and confirm the installer set-up, or press to exit without saving changes. Figure 22-3 Note: See Table 2 for the Installer Set-up Numbers and Settings. Setting Cancel choice Change submenu number or setting Confirm choice Submenu number Figure

35 Table 2. Installer Set-up Menu Set-up Number Installer Set-up Name Setting 35 Notes 0140 MAC and version See MAC and version 0150 Date and time Select number that represents current calendar date and time 0160 Schedule Options 0 - non-programmable 1-7 day programmable 0170 System Type Selection 1-1 heat/1 cool conventional (factory setting) 2 - single-stage heat pump (no auxiliary heat) 3 - heat-only conventional (no fan) Also for 750mV. 4 - heat-only conventional (with fan) 5 - heat-only (power to open and power to close zone valves or normally-open zone valves) When it is changed, the schedule need to be reprogrammed Available options and defaults vary by thermostat. System selection automatically modifies some default settings and/or hides other Installer Set-up options.

36 Set-up Number Installer Set-up Name 0170 System Type Selection 0180 Fan Control in Heating Setting 6 - cool-only conventional 7-2 heat/1 cool heat pump (with auxiliary heat) 8-2 heat/2 cool multi-stage conventional 9-2 heat/1 cool multi-stage conventional 10-1 heat/2 cool mult-istage conventional 11-2 heat/2 cool heat pump (no auxiliary heat) 12-3 heat/2 cool heat pump (with auxiliary heat) 0 - gas or oil furnace equipment controls fan in heating (factory setting) 1 - electric furnace thermostat controls fan in heating Notes Available options and defaults vary by thermostat. System selection automatically modifies some default settings and/or hides other Installer Set-up options. Only shown if conventional system is selected. If heat pump is chosen, fan defaults to electric. 36

37 Set-up Number Installer Set-up Name 0190 Changeover Valve O/B Terminal Energized in Heating or Cooling (Heat Pumps Only) 0200 Back-up Heat Source (Auxiliary Heat) Setting 0 - changeover valve O/B terminal is energized in cooling 1 - changeover valve O/B terminal is energized in heating 0 - heat pump back-up heat source is electric (factory setting) 1 - heat pump back-up heat source is fossil fuel no external fossil fuel kit is controlling heat pump back-up heat. 1 - external fossil fuel kit is controlling heat pump back-up heat 0280 Continuous Backlight 1 - continuous backlight disable 2 - continuous backlight enable Notes Only shown if heat pump system is chosen. Only shown if 2 heat/ 1 cool or 3 heat/2 cool heat pump is chosen. 37

38 Set-up Number Installer Set-up Name Setting 0300 Changeover 0 - manual changeover (factory setting) 1 - auto changeover 0310 Dead band Heating and cooling setpoints can be set no closer than chosen value: 2-2 F (1.5 C) 3-3 F (2 C) 4-4 F (2.5 C) 5-5 F (3 C) 6-6 F (3.5 C) 7-7 F (4 C) 8-8 F (4.5 C) 9-9 F (5 C) 0320 Temperature Indication Scale 0 - Fahrenheit temperature display (factory setting) 1 - Celsius temperature display Notes Shown only if automatic changeover is selected. When it is changed, the schedule need to be reprogrammed. 38

39 Set-up Number Installer Set-up Name 0500 Furnace Filter Change Reminder 0530 Adaptive Intelligent Recovery Setting 0 - furnace filter reminder off 1-10 run time days 2-30 run time days 3-60 run time days 4-90 run time days run time days run time days 1 - Adaptive Intelligent Recovery control is activated (system starts early so setpoint is reached by start of program period). 0 - Conventional Recovery (system starts recovery at programmed time). Notes Run time based on call for fan. 39

40 Set-up Number Installer Set-up Name 0540 Number of periods 0580 Minimum Compressor Off Time 0600 Heat Temperature Range Stop 0610 Cool Temperature Range Stop Setting 0630 WiFi Configure 0 - web 1 - WPS 2 - two periods available (Wake and Sleep) 4 - four periods available (Wake, Leave, Return and Sleep) 5 - five-minute compressor off-time setting (factory setting) 0,2,3,4 - other compressor off-time settings temperature range (1 F increments) of heating setpoint temperature range (1 F increments) of cooling setpoint. Notes Not shown if nonprogrammable is selected. 2 or 4 applies to all days of the week. (when it is changed, the schedule needs to be reprogrammed). Shown in 1/2 C. Shown in 1/2 C. 40

41 Set-up Number Installer Set-up Name Setting 0640 Clock Format hour clock (factory setting) hour clock 0650 Extended Fan On Time Heat 0660 Extended Fan On Time Cool 0 - no extended fan operation after call for heat ends 90 - fan operation is extended 90 seconds after call for heat ends. 0 - no extended fan operation after call for cool ends 90 - fan operation is extended 90 seconds after call for cool ends Keypad Lockout 0 - unlock keypad 1 - lock keypad Notes Not shown if fan operation is set to fossil fuel or in cool-only systems. Not shown in heat-only systems. Unlock all functions are available. Locks only ability to enter and modify user Set-up mode are available. 41

42 Set-up Number Installer Set-up Name 0700 Temperature Display Offset Setting -9 F ~ 9 F ( F as temperature format) -4.5 C ~ 4.5 C ( C as temperature format) 0 F (0 C) (factory setting) 0710 Reset thermostat 0 - no thermostat reset. 1 - resets all Installer Set-up Options to default values and resets schedule to default setting. Notes Only calendar settings and times are retained. 42

43 OPERATION System Select OFF/Heat/Cool Hold Set a permanent hold Up Arrow Raised parameters Cancel Cancel operation Sched Enter schedule mode Fan Select On/Auto Down Arrow Decrease parameters Done Confirm operation Figure 23. Thermostat Keys 43

44 System mode Shows current system mode Wed Shows current data of week WIFI Shows current WIFI status Inside temperature Shows current inside temperature Set temperature Shows current set temperature Fan mode Shows current fan setting Humidity Shows current inside status Following schedule Shows thermostat is following schedule Time Shows current time Figure 24. Thermostat Display 44

45 User Set-Up Follow these steps to enter the User Set-up: 1. Press and hold the key for approximately 3 seconds until the screen changes. The menu number display at bottom right corner. 2. Press the or key to display the submenu, and press the key to enter the submenu. Under submenu, use the or key to set parameters. 3. Press the key to exit and confirm the user set-up, or press to exit without saving changes. Note: See Table 4 for the User Set-up Numbers and Settings, and see the INSTALLER SET-UP for Operation References. 45

46 Table 4. User Set-Up Settings User Set-up Number Description Settings 0140 See MAC and software version 0150 Date and time current calendar date and time 0320 Display temperature in F or C 0 - F setting (factory setting) 1 - C setting 0640 Clock format hour clock (factory setting) hour clock 0670 Screen lockout 0 - all keys available, screen is unlocked (factory setting) 1 - screen is fully locked 0700 Temperature Display Offset -3 F ~ 3 F ( F as temperature format) -1.5 C ~ 1.5 C ( C as temperature format) 0 F (0 C) (factory setting) 0710 Reset Thermostat 0 - No thermostat reset 1 - Resets all Installer Set-up Options to default values and resets schedule to default setting. 46

47 Setting The Date/Time 1. Consult USER SET-UP. Choose submenu number 0150 to enter the date and time setting. 2. Press to switch date to time and use the following format: year, month, day, hour, and minute. Press the or key to adjust the time. (You can advance the time faster by holding the or key.) Figure Press to save and exit or press to exit without changing the date and time. 47

48 Setting The Fan 1. Press to select fan operation. 2. Press again to select ON or AUTO (toggle to re-select). The selected option blinks. 4. Press to save the setting or press to exit without saving changes. ON: Fan is always on. AUTO: Fan runs only when the heating or cooling system is on. Figure 26 48

49 Selecting System Mode 1. Press to display options. 2. Press again to select an option. You may need to press this key two or three times to make a selection. The selected option blinks. 3. Press to save the setting or press to exit without saving changes. Figure 27 49

50 Possible System Modes HEAT: Controls only the heating system. COOL: Controls only the cooling system. OFF: Heating/cooling systems are off. AUTO: Selects heating or cooling depending on the indoor temperature. EMER (heat pumps with aux. heat): Controls auxiliary/emergency heat. Compressor is locked out. Note: The AUTO and EMER system settings may not appear depending on how your thermostat was installed. Note: When under auto mode, press heat and cool. to switch the temperature between 50

51 Setting Temperature Overrides The Smart 5000 has two temperature override options: Override Until and Permanent Override. Override Until Holds temperature temporarily until the next scheduled period time. 1. Press the or key to set the temperature you want. The icon appears above time, and the time becomes the next scheduled period time. 2. Press the key to exit and confirm the changes or press to exit without saving changes. 3. If you want to exit Override Until, press the key. Override Until will be maintained until the next scheduled period time. Note: The current day of the week should already be set correctly. If not, see User Set-up to set the date and time setting. 51

52 Permanent Override Keep user setpoint permanently. 1. Press the key once. Screen shows Permanent Hold. 2. Press the or key to set the temperature you want. 3. If you want to exit Override Until, press the key. 52

53 Cleaning The Thermostat Screen The thermostat has touchscreen interaction. Follow these steps to clean the screen without making thermostat setting changes. 1. Press and hold the key for approximately 3 seconds until the screen changes. The thermostat touch keys are locked for 30 seconds to allow for cleaning. See Figure Use a microfiber cloth or a cloth slightly moistened with water or household glass cleaner to clean the screen. NOTE: Do not use glass cleaners that contain ammonia. DO NOT SPRAY cleaner directly on the screen. Figure 28 When time is up, press the key for an additional 30 seconds, or press the key to return to the Home Screen and normal operation. See Figure

54 IMPORTANT: Do not spray any type of liquid directly on the thermostat itself. If using household glass cleaner, spray the cleaner on a cloth first and then clean the thermostat screen. Figure 29 Screen Locks In this mode, all keys are locked and not functional. The screen displays a lock icon continuously. To unlock the screen, see the User Set-up section. 54

55 Setting Filter Reminders If activated during installation, the filter reminder alerts you when it is time to replace your filter. The word Filter will flash above the the time display. Press after changing the filter, to restart the timer. To change the reminder interval: 1. Press and hold the key for approximately 3 seconds until the screen changes. 2. Press the or key to select the desired interval (in days), then press to save and exit, or press to exit without save. Note: Set-up number 0500 is used to set the furnace filter change reminder. Figure 30 55

56 Connecting to your WiFi network To complete this process, you must have a wireless device. Any of these device types will work: Laptop Tablet Smartphone If you need to start over at any point in this procedure, follow these steps. Restart the thermostat by removing the thermostat from the wall plate. Wait for 5 seconds, and snap it back onto the wall plate. Return to Step 1 in this procedure, which starts on the next page. 56

57 1. Connecting to your thermostat. 1a. On the main menu, press and hold the key for approximately 3 seconds until the WiFi Set-Up blinks. 1b. Connect to the network called WiFly-EZX-10 (the number will vary). Figure 31 Figure 32 57

58 2. Join your home network. 2a. To access the Thermostat WiFi Set-up page, open a web browser on your wireless device and go to 2b. On the Thermostat WiFi Set-up page, click Refresh List to find the name of your home network and select it. 2c. Select the encryption type from the drop down menu, and enter the password if necessary. Click on Figure 33 Save & Reboot to join the network. Note: If your WiFi network does not appear in the list on the Thermostat WiFi Set-up page: Try performing a network rescan by pressing Refresh List. This is helpful in areas with a lot of networks. If you are connecting to a hidden network, then enter the network SSID in the textbox. Select the encryption type from the drop down menu, and enter the password if necessary. Click on Connect to join the network. 58

59 3. Make sure your thermostat is connected. Notice the thermostat display. If you see WiFi Success, you can add thermostat to APP for remote access to your thermostat. If you see WIFI FAILURE, try these steps again. Notes: Please finish the configuration within 5 minutes, or the thermostat will exit configure status. Figure Figure 35

60 PROGRAMMING Table 5. Schedule Default Program Settings Schedule Period Time Heat 60 Setpoints Cool Fan Setting Wake 6:00AM 68 F (20 C) 78 F (26 C) Auto Leave 8:00AM 60 F (16 C) 85 F (29 C) Auto Return 4:00PM 68 F (20 C) 78 F (26 C) Auto Sleep 10:00PM 60 F (16 C) 78 F (26 C) Auto Program Heating and Cooling Schedule Your thermostat can control up to four different schedule periods per day: Wake - Period when you awaken and want your home at a comfortable temperature. Leave - Period when you are away from home and want an energy-saving temperature. Return - Period when you return home and want your home back to a comfortable temperature. Sleep - Period when you are asleep and want an energy-saving temperature. NOTE: Schedule times are in 15-minute intervals.

61 Edit Schedule 1. Press, the screen will change. See Figure 36 and In this case, the time will blink. Press or to adjust the time. Press to display the next setting. Figure Next, the temperature will start to blink. Press or to adjust the temperature. Press to turn to the next time period. 4. Repeat the above steps until four time periods are set. Then, Press to display the next day, until the settings for a week are completed. 5. For the End of Program Setting, press the key to exit and confirm the Figure 37 program setting, or press to exit without saving changes. NOTE: The default Fan setting is Auto and it cannot be programmed. 61

62 Copy One-Day Program After entering a specific day to program, you can copy this into another day to save time when creating a weekly program. For example, if you want to copy the program of Monday to Thursday, follow these steps: 1. Select the program for Monday. Complete the setting for Monday and press. The icon Copy to: appears on the screen, and the icon Tue will blink until selected or skipped. Press to select, press to skip. 2. Copy to Thursday. Press or to select Thursday. Press to copy the setting and the icon Copy to: disappears. 3. To copy for other days, repeat Steps 1 and 2. You can copy to one day or multiple days. 62

63 Reset Schedule To reset the schedule set-up options to the default settings, follow these steps: Press and hold the key for approximately three seconds until the screen looks like Figure 38. Then release the key. Now, the schedule is reset to the default settings shown in Table 5. Figure 38 63

64 Specifications Temperature Setting Range Heating: 40 F to 90 F (4 C to 32 C) Cooling: 50 F to 99 F (10 C to 37 C) Operating Ambient Temperature 32 F to 120 F (0 C to 49 C) Shipping Temperature -30 F to 150 F (-34.4 C to 65.6 C) Operating Relative Humidity IRS 1: 5% to 95% (Non-condensing) ORS-1: 5% to 95% Humidity Display Range 0% to 99% Clock Accuracy Cool Indication Heat Indication Auxiliary Heat Indication Warranty +/- 1 minute per month Thermostat shows Cool On on the screen when Cool is activated. Thermostat shows Heat On on the screen when Heat is activated. Thermostat shows Aux On on the screen when Auxiliary Heat is activated. Five Year Limited Warranty 64

65 Troubleshooting Symptom Problem Solution Display does not come on. Temperature settings do not change. Heating or cooling does not come on. Thermostat is not being powered. The upper or lower temperature limits were reached. Check for 24V AC between C and RC. Check temperature setpoints. Check Installer Set-up Numbers 0600 and 0610, modify as needed. The keypad is fully locked. Check Installer Set-up Number 0670 to change keypad locked options. Thermostat minimum offtime is activated. System selection is not set to Heat or Cool. System type selection is incorrect. Wait up to five minutes for the system to respond. Set system selection to correct position. Check Installer Set-up Number 0170 and make sure correct system type is chosen. 65

66 Symptom Problem Solution Thermostat is calling for Heat (Heat on) or Cool (Cool on) but no heating or cooling is running. Heat does not turn on (Heat on is solid in the display). Heating or cooling equipment is not operating. Heating equipment failure. Loose or broken wire connection between thermostat and heating equipment. 66 Check wiring. Check Installer Set-up Number 0170 and make sure correct system type is chosen. Verify operation of equipment in System Test mode. Check for 24V AC at the equipment on the secondary side of the transformer between power and common. If voltage is not present, check the heating equipment to find the cause of the problem. Check for 24V AC between the heat terminal (W) and transformer common. If 24V AC is present, the thermostat is functional. Check the heating equipment to find the cause of the problem. Check for 24V AC between the heat terminal (W) and transformer common. If voltage is not present, check wire connection (loose or broken) between the thermostat and the heating equipment.

67 Symptom Problem Solution Cooling does not turn on (Cool on is solid in the display) Cooling equipment failure. Check for 24V AC at the equipment on the secondary side of the transformer between power and common. If voltage is not present, check the cooling equipment to find the cause of the problem. Check for 24V AC between the cool terminal (Y) and transformer common. If 24V AC is present, the thermostat is functional. Check the cooling equipment to find the cause of the problem. Fan does not turn on in a call for heat (electric furnace). Loose or broken wire connection between thermostat and cooling equipment. Changeover Valve (Installer Set-up Number 0190) is not configured to match the changeover required by the installed heat pump. 67 Check for 24V AC between the cool terminal (Y) and transformer common. If voltage is not present, check the wire connection (loose or broken) between the thermostat and the cooling equipment. Set Changeover Valve (Installer Set-up Number 0190) to match the changeover required by the installed heat pump.

68 Symptom Problem Solution Both the heating and cooling equipment are running at the same time. Heating equipment is running in the cool mode. Heating equipment does not turn off and heat temperature setting is set below room temperature (Heat on is not in the display). Cannot set the system setting to Heat. The heating equipment is not a heat pump but the System Type (Installer Set-up Number 0170) is set to Heat Pump. Heating and cooling wires are shorted together. Heating equipment is not a heat pump but System Type (Installer Set-up Number 0170) is set to Heat Pump. Heating equipment is not a heat pump but System Type (Installer Set-up Number 0170) is set to Heat Pump. System Type (Installer Set-up Number 0170) is set to Heat Only or Heat Only with Fan. 68 Set System Type (Installer Set-up Number 0170) to match the installed heating and/or cooling equipment. Separate the shorted heating and cooling wires. Set System Type (Installer Set-up Number 0170) to match the installed heating and/or cooling equipment. Set System Type (Installer Set-up Number 0170) to match the installed heating and/or cooling equipment. Set System Type (Installer Set-up Number 0170) to match the installed heating and/or cooling equipment.

69 Symptom Problem Solution Heat on is not in the display. Cool on is not in the display. Wait is in the display. Screen Locked appears on the screen and all or some of the keys do not respond. System setting is not set to Heat and/or temperature setting is not set above room temperature. System setting is not set to Cool and/or the temperature setting is not set below room temperature. Compressor minimum off timer is active. The keypad is fully or partially locked. Set the system setting to Heat and set the temperature setting above the room temperature. Set the system setting to Cool and set the temperature setting below the room temperature. Wait up to five minutes for the cooling or heating (heat pump) equipment to turn on. Check Installer Set-up Number 0670 to change keypad locked options. 69

70 FIVE Year Limited Warranty Robertshaw warrants to the original contract installer, or to the original consumer user, that each new Robertshaw thermostat will be free of defects in materials and workmanship under normal use and service for a period of five (5) years from the date of purchase (the Warranty Period ). If any Product fails within the applicable Warranty Period, Robertshaw shall, at its option, repair or replace the Product or credit the purchase price, provided the Product is returned to Robertshaw s facility or designated agent with transportation charges prepaid, and the Product, upon examination by Robertshaw, is found not to conform to the Warranty. Cost of Product removal, labor, or reinstallation of new Product are not covered under this Warranty and are not the responsibility of Robertshaw. Warranty on Products, parts, components and/or software sold, but not manufactured by Robertshaw, shall be expressly limited to the warranty terms of the manufacturer of such products, components, parts and/or software. This above warranty does not apply to: (i) batteries; (ii) any losses or damages due to misuse, use of the Products in other than their normal and customer manner, accident, abuse, water, fire, neglect, normal wear and tear, negligence (other than Robertshaw s), unauthorized modification or alteration, use beyond rated capacity, unsuitable power sources or environmental conditions, stripped threads, improper installation, repair, handling, maintenance or application or any other cause not the fault of Robertshaw. THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY, TITLE AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ROBERTSHAW BE LIABLE TO CONSUMER, CONTRACTOR, OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES INCLUDING, WITHOUT LIMITATION, LOSS OF USE, LOSS OF PRODUCTION, LOSS OF GOODWILL, LOSS OF CONTRACTS, LOSS OF ANTICIPATED SAVINGS, LOST REVENUES OR PROFITS, OR PROPERTY DAMAGE, REGARDLESS OF WHETHER SUCH LOSS OR DAMAGE IS BASED IN CONTRACT, WARRANTY, 70

71 TORT, NEGLIGENCE, STRICT LIABILITY, INDEMNITY, PRODUCT LIABILITY, OR OTHERWISE, AND EVEN IF ROBERTSHAW HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. REPAIR, REPLACEMENT OR CREDIT OF THE PURCHASE PRICE SHALL CONSTITUTE THE SOLE REMEDIES WITH RESPECT TO DEFECTS IN THE PRODUCTS. THE CONSUMER ASSUMES ALL RISKS AND LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGE RESULTING FROM INSTALLATION AND USE OF THE THERMOSTAT. Some states does not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Return for Warranty Consideration 1. All Products to be considered for warranty must be returned to Company with shipping charges prepaid. 2. Product returned to Company must be packaged in such a manner that will prevent any further damage to the Product during transit. The Warranty terms above shall not apply to any items damaged in transit. 3. An itemized packing slip, including owner s name and address, is required for each shipment to Company of Product(s) to be considered for warranty. The packing slip must contain reason for warranty return, date of installation, date of failure, and a contact name in case further information is required. 4. Within North America (USA and Canada), all cartons must be clearly identified as WARRANTY PRODUCT and returned to: USA Owners: Warranty Department Robertshaw 1921 Anei Circle, Brownsville, TX USA Canada Owners: Warranty Department Robertshaw 4060 Ridgeway Drive, Unit 14 Mississauga, ON L5L5X9 CANADA 71

72 Robertshaw, Uni-Line and SmartSense are trademarks of Robertshaw, its subsidiaries and/or affiliated companies. All other brands mentioned may be the trademarks of their respective owners. Customer Service Telephone Customer Service Facsimile For Technical Service Telephone Facsimile Robertshaw 4/

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/ PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual www.robertshaw.com 2016 Robertshaw 01/16 352-00244-001 IMPORTANT SAFETY INFORMATION WARNING: ELECTRICAL SHOCK HAZARD

More information

CT1001/CT1002 Touchscreen Programmable Thermostat

CT1001/CT1002 Touchscreen Programmable Thermostat CT1001/CT1002 Touchscreen Programmable Thermostat WED Room PM Running As SCHED SYSTEM HEAT AUTO FAN AUTO MORE SCHED HOLD CLOCK SCREEN Contents CT1001/CT1002 Touchscreen Programmable Thermostat Application/Features...2

More information

SMART 1000 Touchscreen Thermostat Installation Manual

SMART 1000 Touchscreen Thermostat Installation Manual by Uni-Line SMART 1000 Touchscreen Thermostat Installation Manual www.robertshaw.com 2015 Robertshaw 12/15 352-00242-001 IMPORTANT SAFETY INFORMATION WARNING: ELECTRICAL SHOCK HAZARD Turn off power at

More information

SMART 2000 Digital Programmable Thermostat Owners Manual Robertshaw 2/

SMART 2000 Digital Programmable Thermostat Owners Manual Robertshaw 2/ SMART 2000 Digital Programmable Thermostat Owners Manual www.robertshaw.com 2015 Robertshaw 2/15 352-00194-001 IMPORTANT SAFETY INFORMATION WARNING: ELECTRICAL SHOCK HAZARD Turn off power at the main power

More information

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat EWT-3102/EWT-3103 Touchscreen Programmable Thermostat WED Room PM Running As SCHED SYSTEM AUTO HEAT FAN AUTO MORE SCHED HOLD CLOCK SCREEN EWC Controls, Inc. 385 HWY 33, Englishtown, NJ 07726 Ph: 732-446-3110

More information

Commercial Touchscreen Thermostat

Commercial Touchscreen Thermostat 55,13M 1/27 Supersedes 12/25 Commercial Touchscreen Thermostat 25 Lennox Industries, Inc. Dallas, Texas, USA APPLICATION Page 1 INSTALLATION INSTRUCTIONS The Lennox Commercial Touchscreen Thermostat provides

More information

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats T7200D,E Series 2000 Commercial Microelectronic Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T7200D,E Thermostats provide electronic control of 24 Vac commercial single-zone heating, ventilating

More information

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8602C Chronotherm IV Deluxe Programmable Thermostats T8602C Chronotherm IV Deluxe mable Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8602 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac single-stage heating and cooling

More information

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats T8624D Chronotherm IV Deluxe mable Multistage Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8624D Chronotherm IV Deluxe mable Multistage Thermostats provides electronic control of 24 Vac single-zone

More information

T8611M Deluxe Programmable Heat Pump Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats T8611M Deluxe mable Heat Pump Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information

Deluxe Programmable Thermostats

Deluxe Programmable Thermostats Deluxe mable Thermostats T8602D INSTALLATION INSTRUCTIONS APPLICATION The T8602D IV Deluxe mable Thermostat provides electronic control of 24 Vac single-stage heating and cooling systems or 750 mv heating

More information

T8600D Chronotherm IV Deluxe Programmable Thermostats

T8600D Chronotherm IV Deluxe Programmable Thermostats T8600D Chronotherm IV Deluxe mable Thermostats APPLICATION INSTALLATION INSTRUCTIONS The T8600 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac singlestage heating and cooling

More information

Deluxe Programmable Heat Pump Thermostat T8611M

Deluxe Programmable Heat Pump Thermostat T8611M APPLICATION Deluxe mable Heat Pump Thermostat T8611M INSTALLATION INSTRUCTIONS The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat INSTALLATION INSTRUCTIONS APPLICATION The T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat provides electronic control of 24 Vac zoned heat pump

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5211 2-Stage Heat Pump Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat Pump Systems Large Display With Backlight Selectable

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T755 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS Owner s Manual Model COMMERCIAL TM BACKLIT DISPLAY HVAC SERVICE PARTS Heat/Cool & Heat Pump 7-Day Programmable Digital Thermostat Use with most Heat Pump Systems: 2-Heat, 2-Cool Stages: 2-Heat, 2-Cool

More information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help? INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency

More information

Programmable Thermostat

Programmable Thermostat Programmable Thermostat with Humidity Control Auto Changeover Dual Power 7-Day, 5-2-Day, or 5-1-1- Day Programmable Configurable for Multiple Systems Large Display with Backlight Selectable Fahrenheit

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 3006 Auto Changeover 7-Day Programmable Hardwired Programmable Electronic Thermostat 7-Day Programmable Single Stage Heat Pump/Non-Heat Pump Systems Backlit Display Single Stage Heat/Cool Systems Field

More information

PRO Installation. Thermostat Wi-Fi

PRO Installation. Thermostat Wi-Fi PRO Installation Thermostat Wi-Fi 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest connected

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8800 Universal Communicating Thermostat Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 2 Thermostat mounting...

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T915 Thermostat Applications Guide Des cription Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux.

More information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications 1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Heat Pump or 2 Heat / 2 Cool Conventional Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE

More information

INSTRUCTION MANUAL P Heating and 1 Cooling

INSTRUCTION MANUAL P Heating and 1 Cooling REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:

More information

SAS6000UTK-7 UNIVERSAL THERMOSTAT

SAS6000UTK-7 UNIVERSAL THERMOSTAT SAS6000UTK-7 UNIVERSAL THERMOSTAT Used with Single Stage, Multi-Stage, Heat pump Installation and operation instructions SPECIFICATION: Power Supply Dual Power 24VAC (18-30VAC,50/60Hz) or Battery Powered

More information

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling INSTRUCTION MANUAL TS21 2 Heating and 1 Cooling WELCOME TO Flexible applications - Universal and easy to install in residential or commercial environments. Advanced features - Precision electronics provide

More information

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat T6 Pro Hydronic Programmable Thermostat User Guide Package Includes: T6 Pro Hydronic Programmable Thermostat Floor sensor (model AQ12C20) UWP Mounting System Honeywell Standard Installation Adapter (J-box

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5811 2 Heat/2 Cool Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat/2-Stage Cool Systems 2-Stage Heat Pump Systems Large

More information

CT500 Electronic Thermostat

CT500 Electronic Thermostat CT500 Electronic Thermostat OWNER'S GUIDE MERCURY NOTICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of it properly.

More information

tcu.z Commercial Programmable Thermostat Installation Instructions

tcu.z Commercial Programmable Thermostat Installation Instructions Application Mercury Notice Installation The tcu.z Commercial Programmable Thermostat controls 24-VAC commercial single-zone heating, ventilating, and air conditioning (HVAC) equipment. It consists of a

More information

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats 2007 Lennox Industries Inc. Dallas, Texas, USA OWNER S GUIDE ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats IMPORTANT Read and save these instructions. 506067 01

More information

Smart Temp. Model

Smart Temp. Model Smart Temp Model 42-160 SINGLE STAGE PROGRAMMABLE THERMOSTAT 1 Heat / 1 Cool Single Stage Thermostat. 5+2 Programmable, Compatible with Gas Heat & Heat Pump System Installation and Operation Manual SPECIFICATIONS:--------------------------------------------------------------------------------

More information

T8411R Electronic Heat Pump Thermostat

T8411R Electronic Heat Pump Thermostat T84R Electronic Heat Pump Thermostat INSTALLATION INSTRUCTIONS The T84R Heat Pump Thermostat provides 24V control of two-stage heating and one-stage cooling heat pump system with manual changeover from

More information

For Quick Set-Up go to Page 14

For Quick Set-Up go to Page 14 Talking Thermostat Model VT3000 Guide SmartWay Solutions, Inc. US Patent 6,608,560 & 7,62,253 For Quick Set-Up go to Page 4 Model VT3000, a universal thermostat for use on most Gas or Electric, Conventional

More information

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat. Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat

More information

Emerson Blue Easy Set 1H/1C

Emerson Blue Easy Set 1H/1C Emerson Blue Easy Set 1H/1C Model: 1F86EZ-0251 Non-Programmable Thermostat with 3 Temperature Pre-Sets Home, Sleep and Away Installation Instructions and User Guide Message to Homeowner Congratulations

More information

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers TopTech models: TT-N-851 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652C 8400 Tstat Install.indd 1 10/13/09 11:08:56 AM Table of contents Installation Installation location

More information

TCONT602AF22MA. Programmable Comfort Control. Installation Instructions 18-HD37D1-1

TCONT602AF22MA. Programmable Comfort Control. Installation Instructions 18-HD37D1-1 TCONT602AF22MA Programmable Comfort Control Installation Instructions 18-HD37D1-1 Product Application This Comfort Control provides electronic control of 24 VAC single-stage and multistage heating and

More information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications 1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Conventional and Heat Pump Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE READ ALL

More information

User s Manual Quick Start Installation and Programming

User s Manual Quick Start Installation and Programming 9720 DELUXE PROGRAMMABLE THERMOSTAT INTEGRATED COMFORT SOLUTIONS H HEAT PUMP 7 Day Programmable 3 Heat / 2 Cool User s Manual Quick Start Installation and Programming 110-662 W A R R T A N Y PRODUCT FEATURES

More information

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat RTH8500 Series Programmable Thermostat Quick Installation Guide Included in your box Quick Install Guide Screws and anchors UWP Mounting System (UWP) RTH8500 Thermostat Tools you will need Tools you may

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8476 Thermostat with Event-Based Air Cleaning Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 3 Outdoor

More information

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents. INSTALLATION MANUAL This manual covers TopTech models: TT-S-755H Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675-TS32 3 Heating and 2 Cooling

TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675-TS32 3 Heating and 2 Cooling TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675-TS32 3 Heating and 2 Cooling www.diversitech.com Technical Support 1-800-995-2222 675-TS32 3 Heating and 2 Cooling with Extra Programmable Output Standard

More information

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat PRO Installation Touch Wi-Fi Thermostat 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications Premier Series Non-Programmable Thermostats MODEL 3000 MODEL 3200 1 2 3 4 5 Specifications Installation Testing Your New Thermostat Programming User Settings Temperature Adjustment WARNING

More information

User s Manual

User s Manual 997-060180-4e User s Manual 8403-060 Menu Driven Display 1120-445 I. CONTROLLER OPERATION ADJUSTING TEMPERATURE (Temporary Override when in Programmable mode) 1. Before you can adjust the temperature,

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652A 8400 Tstat Install.indd 1 7/23/09 2:20:45 PM Table of contents Installation Installation location recommendations...

More information

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat PRO Installation Touch Wi-Fi Thermostat 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest

More information

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins Table of Contents Parts Diagram........................................................... 1 Icon Descriptions......................................................... 2 Specifications...........................................................

More information

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION Your new White-Rodgers Digital Thermostat

More information

ACONT600AF11MA Programmable Comfort Control

ACONT600AF11MA Programmable Comfort Control ACONT600AF11MA Programmable Comfort Control Installation Instructions Pub. No. 11-HD02D10-4 69-1832-03 Product Application This Comfort Control provides electronic control of 24 VAC single-stage heating

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications Premier Series Non-Programmable Thermostats MODEL 3000 MODEL 3200 1 2 3 4 Specifications Installation Testing Your New Thermostat Programming User Settings WARNING Important Safety Information

More information

7-Day. Digital Thermostat. residential. & 2-cool

7-Day. Digital Thermostat. residential. & 2-cool Digital Thermostat residential THERMOSTAT T1100FS 7-Day PROGRAMMABLE up to 2-heat & 2-cool PUMP Control up to 2 Heat & 2 Cool Stages 7-Day Programmable 4 Settings/Day Auto Changeover 5 minute Built-In

More information

VX SERIES Wireless Thermostat with Occupancy Sensor

VX SERIES Wireless Thermostat with Occupancy Sensor VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat

More information

EL-TSTAT-8820 Safety & Installation Instructions

EL-TSTAT-8820 Safety & Installation Instructions EL-TSTAT-8820 Safety & Installation Instructions TABLE OF CONTENTS WI-FI SETUP Wi-Fi Setup 2 INSTALLATION Installation location recommendations 3 Outdoor temperature sensor (included) 3 Remote temperature

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T725 Thermostat Applications Guide Des cription Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications 1 2 3 4 5 Builder Series Programmable Thermostats 2000 2000NC 2200 2200NC Single Stage Heat / Cool Conventional and Heat Pump Multi-Stage 2 Heat / 1 Cool Conventional and Heat Pump Before

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5812 3 Heat/2 Cool Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 3-Stage Heat/2-Stage Cool Systems 3-Stage Heat Pump Systems Large

More information

1 For All Programmable Digital Thermostat

1 For All Programmable Digital Thermostat OWNER'S MANUAL P/N P374-2300FM 1 For All Programmable Digital Thermostat Am OFF OVERRIDE Meets California Title 24 unts flush to the wall 7 Day Programmable 3 Occupied, 1 Unoccupied Auto-Changeover Large,

More information

Programmable Digital Thermostat

Programmable Digital Thermostat OWNER'S MANUAL P/N P474-2150 1 For All Programmable Digital Thermostat Mo TOTALINE 72 74 COOL AUTO HEAT 70 Optional Locking Cover Meets California Title 24 Dual Setpoint 5+1+1 Day Programmable 3 Occupied,

More information

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS 9901i 9915i 9920i DELUXE MABLE THERMOSTATS User's Manual Menu Driven Display Integrated Damper / Economizer Control 24 VAC with Worry-Free Memory Storage English and Spanish Menus Fresh Air Control 110-1069

More information

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT CONTENTS Installation Instructions for Heating & Air Conditioning 1F79 n-programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...

More information

CT2800 Programmable Thermostat

CT2800 Programmable Thermostat CT2800 Programmable Thermostat INSTALLATION AND PROGRAMMING INSTRUCTIONS Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically

More information

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

1 For All Programmable Digital Thermostat. Meets Residential California Title 24 OWNER'S MANUAL P/N P374-1100FM 1 For All Programmable Digital Thermostat 72 74 Am I2:00 AUTO 70 unts Flush to the Wall 7 Day Programmable 4 Time Periods per Day Auto Changeover Large, Easy To Read Display

More information

CT2700 An Electronic Round Programmable Thermostat

CT2700 An Electronic Round Programmable Thermostat CT2700 An Electronic Round Programmable Thermostat USER S GUIDE MERCURY SWITCH TYPICAL LOCATION OF A MERCURY SWITCH IN A THERMOSTAT M064 RECYCLING THERMOSTAT If this thermostat is replacing a control that

More information

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE Installation and Operation Instructions for RS332N 3-Heat / 2-Cool Non-Programmable Setback Thermostat with the Industry s Most Advanced Remote Sensor Bus for Gas, Electric, & Heat Pump Systems www.robertshawclimate.com

More information

Must be installed by a trained, experienced technician

Must be installed by a trained, experienced technician Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8321097: For up to 3 Heat/2 Cool heat pump or up to 2 Heat/2 Cool conventional

More information

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS 110-1069B.qxd 3/4/05 3:51 PM Page 1 9901i 9915i 9920i DELUXE PROGRAMMABLE THERMOSTATS User's Manual Menu Driven Display Integrated Damper / Economizer Control 24 VAC with Worry-Free Memory Storage Fresh

More information

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

Honeywell CT8602 PROGRAMMABLE THERMOSTAT Honeywell CT8602 PROGRAMMABLE THERMOSTAT Seven Day Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT8602 OWNER S GUIDE Para obtener un documento con las instrucciones

More information

(-)HC-TST213UNMS 5/1/1 Day 5/2 Day Non-Programmable. Yes

(-)HC-TST213UNMS 5/1/1 Day 5/2 Day Non-Programmable. Yes Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Universal Thermostat

More information

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H Instruction Manual US PAT: 6,824,069 6,786,421 Models: CT03TS21 CTO3TS32 CTO3TS32H www.climatouch.com AED Electronics Inc. 5758 Royalmount Avenue Montreal, Quebec,Canada H4P 1K5 Technical Support: 1-866-90TOUCH

More information

User s Manual Quick Start Installation and Programming. 7 Day Programmable 3 Heat / 2 Cool B DELUXE PROGRAMMABLE THERMOSTAT

User s Manual Quick Start Installation and Programming. 7 Day Programmable 3 Heat / 2 Cool B DELUXE PROGRAMMABLE THERMOSTAT Maple Chase Company 2820 Thatcher Road Downers Grove, Illinois 60515 United States of America INTEGRATED COMORT SOLUTIONS 9710 DELUXE PROGRAMMABLE THERMOSTAT E ELECTRIC 7 Day Programmable 3 Heat / 2 Cool

More information

SAS6000UTK-7-WIFI OPERATING INSTRUCTION

SAS6000UTK-7-WIFI OPERATING INSTRUCTION SAS6000UTK-7-WIFI OPERATING INSTRUCTION 1 This manual apply for SAS6000UTK-7-WIFI,used with Single Stage,Multi-Stage,Heat pump and has mobile control function. SPECIFICATION Power Supply Dual Power 24VAC

More information

WARNING Important Safety Information

WARNING Important Safety Information Premier Series Programmable Thermostats MODEL 5000 1 2 3 Specifications Installation Testing Your New Thermostat Programming User Settings WARNING Important Safety Information Additional Operation Features

More information

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM Owner s Manual Model S1-THEH21P5S HVAC SERVICE PARTS TM Heat Pump 5+2 Programmable Digital T h e rm ostats t a t BACKLIT DISPLAY Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool Control up

More information

Model NT20e Installation Guide

Model NT20e Installation Guide Model NT20e Installation Guide Rev 1.4 Page 2 of 14 1. Preparing for Installation CAUTION Do not remove the NT20e from the Electro-static bag until instructed from this installation guide. The NT20e is

More information

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool

More information

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE Emerson Blue Wireless Comfort Interface - Homeowner User Guide Message to Homeowners Congratulations on choosing the Emerson Blue

More information

Detailed Installer Guide

Detailed Installer Guide Detailed Installer Guide Programmable Thermostats PREMIER SERIES 5020 Single Stage Heat / Cool Conventional or Heat Pump 5220 Up to 3 Heat / 2 Cool Heat Pump Up to 2 Heat / 2 Cool Conventional 1 Specifications

More information

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM Operating Manual UtilityPRO TM Series Touchscreen Programmable Demand Control Thermostat 85-3126 BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen keys. To prevent

More information

MagicStat CT3300 Programmable Thermostat

MagicStat CT3300 Programmable Thermostat MagicStat CT3300 Programmable Thermostat Installation and Programming Instructions Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model

More information

CAUTION: ELECTRICAL HAZARD

CAUTION: ELECTRICAL HAZARD R R Installation Guide 53DF50-HW hermostat System ypes Cool Only (single stage) Heat Pump (with electric heat) CAUION: ELECRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power

More information

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24 OWNER'S MANUAL P/N P374-1000FM 1 For All Programmable or Non-Programmable Switchable Digital Thermostat 72 74 Am AUTO 70 Mounts Flush to the Wall 1 Day Programmable or Non-Programmable 4 Time Periods per

More information

- User Brochure Programmable Thermostat 510

- User Brochure Programmable Thermostat 510 - User Brochure Programmable Thermostat 510 U 510 09/09 Congratulations on the purchase of your tekmar programmable thermostat. This thermostat combines easy-to-use programming with advanced features to

More information

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL USERS INFORMATION MANUAL Heating & Cooling Systems L TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. Mo 72 74 AUTO HEAT 70 Heat Pump &

More information

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information Model 8800 Universal Communicating Thermostat Owner s Manual Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS 61000762A 8800 Tstat Owners.indd 1 3/28/11 4:19:57

More information

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL USERS INFORMATION MANUAL Heating & Cooling Systems L TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. AUTO Heat Pump & Heat Cool Dual Setpoint

More information

Disclaimer. Trademarks. Copyright. Warranty

Disclaimer. Trademarks. Copyright. Warranty 1 Disclaimer Trademarks Copyright Control4 makes no representations or warranties with respect to any Control4 hardware, software, or the contents or use of this publication, and specifically disclaims

More information

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide. INSTALLATION MANUAL This manual covers TopTech models: TT-N-721 and T721 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux.

More information

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

TB8220U Commercial Programmable Thermostat OWNER S GUIDE TB8220U Commercial Programmable Thermostat OWNER S GUIDE 63-2643 Contents Features... 3 Main Screen Selections... 4 Programming Heating and Cooling Schedule... 6 Operating the Thermostat... 10 Replacing

More information

VisionPRO 8000 with Wi-Fi

VisionPRO 8000 with Wi-Fi VisionPRO 8000 with Wi-Fi FEATURES PRODUCT DATA Thermostat acquires weather data through either a wired sensor or an Internet connection, making for a truly universal installation. U1 Terminals One set

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 3100 Premier Series Non-Programmable 2 Heat / 2Cool & Heat / Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL Model TME- * * Balance of model number is determined by customer specifi ed limits and Setbacks. AUTOMATIC SETBACK THERMOSTAT LIGHT SENSING OR CONTACT CLOSURE FOR LOW VOLTAGE

More information

RC-2000 Thermostat Installation Instructions

RC-2000 Thermostat Installation Instructions RC-2000 Thermostat Installation Instructions DESCRIPTION The RC-2000 is a precision digital thermostat designed for 24 VAC heating and cooling systems. The RC-2000 will support the following systems: Single

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series Premier Series MODEL 5000 USER MANUAL 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including

More information

OWNER'S MANUAL T0140. Contents Page #

OWNER'S MANUAL T0140. Contents Page # Digital Thermostat residential THERMOSTAT T0140 NON- PROGRAMMABLE up to 2-heat & 1-cool PUMP Stages: 2-Heat, 1-Cool Battery or System Powered Auxiliary Heat Indicator Fahrenheit or Celsius Bi-Color LED

More information