Unico Presentation. Introducing

Size: px
Start display at page:

Download "Unico Presentation. Introducing"

Transcription

1 Introducing

2 Combines all the efficiencies and performance of inverter technology with all the features and benefits of The Unico System

3 Made in conjunction with Argoclima Group is a European leader in HVAC technology and applications. The headquarters and the main factory of the Argoclima Group, is located in the north of Italy, near Milan.

4 What is iseries? An Inverter Heat Pump Can be used for Air Conditioning, Heating, and Domestic Hot Water (DHW) through use of an optional de-superheater Outdoor and Indoor units can be matched to the desired configuration + =

5

6 4 Zone Dampers in Plenum

7 What is iseries? SINGLE SPLIT: One Outdoor Unit and One Indoor Unit MULTISPLIT: One Outdoor Unit and up to Four Indoor Units SINGLE SPLIT One outdoor unit can be both single split and multi-split MULTISPLIT

8 FEATURES Unico Presentation AND BENEFITS

9 Features Unico Presentation that the market leaders in ductless air conditioning and heating do NOT have: Auxiliary Heat Lower Temperatures for Heating Operation Better defrost system, can heat when the system is in defrost mode Same outdoor unit can be used for both one to one and multi-split applications Both SDHV and High Wall Mount on one outdoor unit

10 Features that the market leaders in ductless air conditioning and heating do NOT have: Ability to do zoning with dampers A variety of third party thermostats Ability to cool or heat multiple rooms (Central Air- Conditioning vs. Room Air Conditioning)

11 Unico SPECIFICATIONS Presentation

12

13 Higher SEER IS30G80 with non-ducted inside units : SEER IS36G110 with non-ducted inside units: SEER IS30G80 with Unico and non-ducted SEER IS36G110 with Unico and non-ducted SEER iseries with Unico only SEER (from AHRI directory of Variable Speed Mini Duct Heat Pumps)

14 OPERATION

15 Inverter Technology Uses 230V 1 Phase Power Converts to DC power Uses a SVPWM technology to convert DC power to 3 Phase DC Speeds up or down condensing unit and fans to meet load

16

17 SVPWM 180 Inverter Using a Pure Sine Wave. Takes care of electrical Noise in a system

18 Wide modulation range Larger modulation means less electric consumption and more efficiency

19 OPERATING LIMITS

20 SDHV RATINGS

21 New Cooling Only Guidelines We have 100% capacity at 5F outdoor temperature We have at least 65% of capacity at -15F outdoor temperature These tests involved NO wind baffles Same performance in 5 mph wind tests

22

23 UNIT SELECTION

24 Indoor units range IS12MPA IS24MPA U1218L-EA2TX M2430BL1-EA2 & M2430CL1-A M3036BL1-EA2 & M3036CL1-A

25 A

26 iseries and the Unico System Unico Presentation These Unico SDHV systems can be used in conjunction with the ISeries. U1218, M2430, M3036 Different Control Box and Coil Module SDHV

27 New Unico Units Unico Units U1218-1EA2AX M2430BL1-EA2 M2430CL1-A M3036BL1-EA2 M3036CL1-A Description FCU, 230V for iseries with Heat Pump Coil 2430 Module, Blower with iseries Inverter Control Board, EC Motor, 220V 2430 Module, Heat Pump Coil, iseries Inverter 3036 Module, Blower with iseries Inverter Control Board, EC Motor 220V 3036 Module Heat Pump Coil, iseries Inverter

28 * * Item 17 supplied with Outdoor Unit

29 MP SERIES INDOOR UNIT

30

31

32 Sizes IS12MPA Up to 12,000 btu s Size A IS24MPB Up to 24,000 btu s Size B

33

34 Drains Usually No Trap Mini-Condensate Pump (common)

35 REFRIGERANT CIRCUIT SETTINGS FOR HIGH WALL MOUNT UNITS

36

37 COMMUNICATION CHANNEL SETTINGS FOR HIGH WALL MOUNT UNITS Third and fourth settings of SW1 as shown

38

39

40

41 Wiring connection MPA Series IF USING THE WALL MOUNT UNIT THE ELECTRIAL SUPPLY COMES FROM THE OUTDOOR UNIT

42

43 Less than one amp current, no breaker

44 Remote Control Only way to control the High Wall Mount Unit Optional for use with SDHV (Unico) Air Handler

45

46

47

48 REFRIGERANT LINES

49 Refrigerant Line Circuits Refrigerant Line Circuits Labeled from 1 to 4 Hook up the first indoor unit to 1, second to 2, etc. Outdoor units have up to four circuits

50 Line Set Sizes For Size A : ¼ X 3/8 For Size B and Size C : ¼ X ½ For Size D : 3/8 X 5/8 Use flare nuts included with outdoor unit to attach

51

52

53 For One Indoor Unit Hook Up the Circuit Line Numbered 1

54 Two Indoor Units Refrigerant Line Connections

55 Unico Size Presentation M3036 Detail Suction Line Adapter Must Be Used

56 Unico Outdoor Presentation units IS36G110 emix LINE Circuit 3 Circuit 2 Circuit 1

57

58 Torque Wrench Yellow Jacket Model #60650

59 Torque Settings (US) Size Tightening Torque ¼ ft./lb. 3/ ft./lb. ½ ft. lb. 5/ Ft. LB

60 LINE SET LIMITATIONS

61 Four Line Set Lengths Total Line Set length Longest Single Line Set Height Difference Between Indoor and Outdoor Unit Height Difference Between Indoor Units

62 Distance limits Two type of limits are to be considered: distance limits between indoor and outdoor units (Ln) and height difference limits (Hn).

63

64

65 Adding Refrigerant ¼ x 3/8 Line =.16 oz. per additional foot ¼ x ½ Line =.22 oz. per additional foot 3/8 x 5/8 Line =.49 oz. per additional foot

66 ELECTRICAL

67

68 Electrical Power to Unico Air Handler If you are using a Unico System (SDHV), the power is supplied to the control board on the Unico Blower Module Must be 230v single phase power DO NOT POWER THROUGH OUTDOOR UNIT!

69

70

71 Communication Wire Must be RF shielded (A foil shield with drain wire) Ground ONE end (does not matter which end) 18/2 with shield and drain wire is very common All iseries Units will require a communication wire connection to the outside unit

72

73 Dip Switches 1 and 2

74 Setting the Switches

75 The IndoorB Board Includes two Fuses F1 and F2 F1 is 3.15A 250V (Unico P/N A ) F2 is 100mA 250V (Unico P/N A )

76 The IndoorB Board (See installation manual) provides for: Alarm Condensate Pump Float Switch

77 Two Stage Heat Pump Thermostat

78 Components of the Thermostat Board: Terminal Block: R: 24V power C: Power, Common B: Reversing Valve (energize on heat) Y1: Stage One Heating/Cooling Y2: Stage Two Heating/Cooling

79

80 Note: Operation of fan only in heating mode can be overridden by call for heating

81 LED s

82

83 Components of Thermostat Adapter Board Outputs C: Common S1: Stage 1 Supplemental Heat S2: Stage 2 Supplemental Heat S3: Stage 3 Supplemental Heat AUX : 24V output (for hot water coil)

84 Sequence of Operation For Electric Backup: In heating mode for 20 minutes and thermostat not satisfied, S1 turns on After 20 minutes, then S2 is energized After another 20 minutes then S3 is energized

85 For Boiler Changeover (SDHV) Install jumper plug on the J5 (Humidity Sensor) connector

86 Hot Water Operation By default: Shuts off heat pump at 32F outside temperature Keeps fan running at High airflow Re-starts heat pump when temperature reaches 37F Can be adjusted

87 To Adjust Boiler Changeover Temperature Please refer to the earlier section on the remote control

88 MMI BOARD

89 PREPARING FOR INSTALLATION

90 Refrigerant circuit GAS LINE

91

92

93 I Series Defrost

94 Intelligent Defrost and Dynamic Cold Draft Unico Presentation No Cold Blow = No Cycle Losses More Efficient, You never stop heating in the Defrost Mode A trickle of hot gas directly from the compressor is used to prevent ice from forming

95 Cold Climate Heating I Series include two electric heaters in the outdoor unit 1. A condensate drain pan heater to prevent freezing 2. A crankcase heater to boil off refrigerant from the compressor to prevent liquid slugging

96 System Setup Both indoor and outdoor unit are powered off Disconnect the communication wires C1 and C2 Connect the USB-Serial Adapter to C1 and C2 Disconnect the USB-Serial Adapter from the laptop The updater program is closed

97 Attaching Communication Cable

98 Outside Unit LED Detail All Five LED s Should Light

99 MMI BOARD (In Unico Control Box) Both Blue and Green Should be solidly Lit (If programming inside unit)

100 Diagnostics

101 Run Service Loggers IS30 outside Unit

102 Launch the Logger This screen will appear

103 Set Proper COM port

104 Assign A File Name Be sure the file is easy to remember for future reference Use today s date and the job address for example

105 Click Start Run for 15 Minutes

106 End Diagnostics Click Stop File will save as a.zip file Keep a copy for your records and send an to service@unicosystem.com Resume normal operations

107 To Find Firmware Version

108 Find Indoor Firmware Version

109 Indoor Version

110 High Wall Mount

111 Outdoor Units

112 Troubleshooting Points to remember: 1. Respect the line lengths 2. Check the matchup matrix 3. Check the dip switches and cables -

113 Troubleshooting Unico Presentation RAT=Room Air Temp 12V ICT=Indoor Coil Temperature NOTES - The troubles are showed according to a priority list that is, in case of more than one trouble present, is always showed, at first, the one with the highest priority (1 2 3 etc.). - Sensor damaged means a situation where sensor is short-circuited or opened. - In case of damaged sensors, the system (CM, FMO, FMI etc.), if in OFF state, does not start.

114

115

116

Unico Presentation. Abridged iseries

Unico Presentation. Abridged iseries Abridged iseries Combines all the efficiencies and performance of inverter technology with all the features and benefits of The Unico System Argoclima Group is a European leader in HVAC technology and

More information

Unico Training. Welcome to Unico!

Unico Training. Welcome to Unico! Welcome to Unico! UNICO Inc Who are we? Unico Inc. is a family owned and operated manufacturing company. Unico Inc. is the largest manufacturer of SDHV systems in the world. Unico Inc. is manufactured

More information

Welcome to Unico! The Small Duct High Velocity (SDHV) System

Welcome to Unico! The Small Duct High Velocity (SDHV) System Welcome to Unico! The Small Duct High Velocity (SDHV) System Advantages to SDHV Uses up to one-third the space of a conventional ducted system No need to drop ceilings, build soffits, etc. Preserves architectural

More information

The Benefits Really Add Up

The Benefits Really Add Up Unico, Inc. 7401 Alabama Ave. St. Louis, MO 63111 Unico, Inc. manufacturing plant and sub-assembly plant +1 800 527 0896 +1 314 481 9000 www.unicosystem.com Unico, Inc. is the leader in Small Duct High

More information

December 2014 Pints with Pete

December 2014 Pints with Pete December 2014 Pints with Pete The Year In Review Busy Year at Unico New Products VAH: 2 2 ½ Ton, 2 ½ to 3 Tons, 3 to 3 ½ Tons I Series Outdoor Units IS24 IS30 IS36 New Products at Unico I Series Indoor

More information

Training Manual UNICOSYSTEM.COM (800) Outlets are available in styles and finishes to match any décor.

Training Manual UNICOSYSTEM.COM (800) Outlets are available in styles and finishes to match any décor. Training Manual UNICOSYSTEM.COM (800) 527-0896 Outlets are available in styles and finishes to match any décor. THE UNICO SYSTEM WORKS WHERE OTHERS CAN T Zoning Individual rooms and zones can always be

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems PRODUCT SPECIFICATIONS ZONING IHARMONY Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems Bulletin No. 20663 November 207 Supersedes August 205 COMPONENTS AND EQUIPMENT

More information

RCS Residential Control Systems Inc.

RCS Residential Control Systems Inc. RCS Residential Control Systems Inc. Model TZ16 Z-Wave Communicating Thermostat with Rev P HVAC Control Unit INSTALLATION AND OPERATION MANUAL DCN: 141-00882 Rev 02 5/18/06 This manual applies to the following

More information

Troubleshooting the Indoor AHU as a Standard Product

Troubleshooting the Indoor AHU as a Standard Product Troubleshooting the Indoor AHU as a Standard Product Indoor Unit Circuit Board Indoor Unit Circuit Board Schematic The TECHs Need to Understand the Status and Fault Codes by LED Lights The control board

More information

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Concealed Duct Heat Pumps Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH

More information

Vertical Air Handler Unit

Vertical Air Handler Unit Bulletin 20-019 (September 2016) Vertical Air Handler Unit For cooling, the unit is designed for R-410A refrigerant (both A/C and Heat Pump) or a chilled water coil. For heating, the unit offers an optional

More information

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

EnviroZone-4 & EnviroZone-2 Quick-Start Guide EnviroZone-4 & EnviroZone-2 Quick-Start Guide This guide is intended to give the installer a brief set of instructions about how to set up the FHP EnviroZone System. For more detailed information about

More information

Unico Training. Class for R E Michel Salesmen

Unico Training. Class for R E Michel Salesmen Class for R E Michel Salesmen Outlet (UPC-56B) Sound Attenuator (UPC-26C) Elbow Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling Modules (MC2430, MC3642,

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support Contact information Instructors: Don Reynolds 616-560-9903 Doug McGee 517-294-3932 Factory Tech Support 888-593-9988 Product Improvements for 2017 Todays Objectives Job Site Information Sheets Low Ambient

More information

Installation & Operation Instructions

Installation & Operation Instructions Installation & Operation Instructions Installation Precautions This Zoning System must be installed by a qualified HVAC Contractor! Caution - Electrical Hazard Can cause personal injury or equipment damage.

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The

More information

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL 500644 FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES A047-001 FIGURE 1: Demand Defrost Control Module ANTI-SHORT CYCLE DELAY

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS - Wall-mount indoor unit - OPERATING LIMITS Cooling Maximum conditions Heating Maximum conditions Outdoor temperature : 122 F (50 C) D.B. Outdoor temperature : 75 F (24 C) D.B.

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Service Manual Indoor HSU09VHG(DB)-W HSUVHG(DB)-W HSU8VHH(DB)-W HSUVHG(DB)-W Outdoor HSU09VHG(DB)-G HSUVHG(DB)-G HSU8VHH(DB)-G HSUVHG(DB)-G Design may vary by model number.

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the

More information

Installation & Operation Instructions

Installation & Operation Instructions Installation & Operation Instructions 200 MPS Series Arzel Zoning Technology, Inc. 4801 Commerce Pkwy. Cleveland, OH 44128 Ph: (216) 831-6068 or Toll-Free (800) 611-8312 Fax: (216) 831-6074 www.arzelzoning.com

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

TECHNICAL NOTICE: Supplemental External Heat Control/Reduce Fan Operation Indoor Unit Firmware Version: (14/06/13) or newer

TECHNICAL NOTICE: Supplemental External Heat Control/Reduce Fan Operation Indoor Unit Firmware Version: (14/06/13) or newer Indoor Unit Firmware Version: (14/06/1) or newer Page 1 of 5 Added features with newest indoor unit firmware: External, supplemental heat source control Added fan control programming for satisfied zones

More information

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH #700837 190 PINT MANUAL Rated at 170-pints per day at 86 F/80% RH, 105 pints per day, AHAM - (80 F/60% RH) Rating @ 190Pint 86 F 80%RH 115Pint 80 F 60%RH ONE: IMPORTANT SAFETY INSTRUCTIONS Please read

More information

Safety and Installation Instructions Model 1700

Safety and Installation Instructions Model 1700 Dehumidifier Filter Access Humidity Control Inlet Filter Access Outlet Service Access Port Wiring Access Wire Routing Port Drain On/Off Switch Safety and Installation Instructions Model 1700 INSTALLER

More information

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 8129 VARIABLE REFRIGERANT A. Variable refrigerant volume HVAC system includes: 1. Outdoor/condensing unit(s). 2. Indoor/evaporator units. 3. Branch selector

More information

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM # ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM DETAIL Labor Material FURNACE COMPONENTS 1 Furnish & Install Sight-Impaired Thermostat For Heating and Cooling

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH 33-44-50 CAH 49-54-70 CAH VARIABLE SPEED AIR HANDLERS DIMENSIONS... 3 TECHNICAL SPECS... 4 INSTALLATION DON TS... 5 INSTALLATION DO S... 6 FREEZE STAT REQUIRED

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Service Manual Indoor AW09ESVHA AWESVHA AW8ESVHA AWESVHA Outdoor U09ESVHA UESVHA U8ESVHA UESVHA Design may vary by model number. Please read this manual before using the

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

Installation, Safety & Maintenance Manual Model 1750A/1770A

Installation, Safety & Maintenance Manual Model 1750A/1770A Central Dehumidifier Filter Access Humidity Control Inlet Outlet Service Access Port Filter Access Wiring Access Wire Routing Port Drain On/Off Switch Installation, Safety & Maintenance Manual Model 1750A/1770A

More information

Specifications and Performance

Specifications and Performance R35C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh 2.6 3.5 4.4 5.3 kw Heat Pump Nominal Capacities 9,000

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair. WALL-MOUNTED HEAT PUMPS SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) UP TO 23 SEER UP TO 11 HSPF HEATING UP TO -20 C 10 years* *See details on the back Warranty Exclusive distributor in Quebec descair.ca What

More information

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC Viega Zone Control Applications The Viega Zone Control is a wiring and switching center for individual and / or multi- room control. The Zone Control simplifies wiring between Thermostats and Powerheads.

More information

Lennox Mini-Split Systems Year-Round Comfort and Performance

Lennox Mini-Split Systems Year-Round Comfort and Performance Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:

More information

START UP FORM PACKET

START UP FORM PACKET START UP FORM PACKET Condensing Unit and Evaporator DIVISIONS OF RAE CORPORATION 4492 Hunt St. - Pryor, OK 74361 - (918) 825-7222 - Fax (918) 825-6366 www.rae-corp.com RAE Corporation Condensing Unit

More information

Technical Manual Binair Monobloc Heat Pump

Technical Manual Binair Monobloc Heat Pump Technical Manual Binair Monobloc Heat Pump MODEL BINAIR12 Introduction Disassembly of the machine must be carried out by any professional or any special agency assigned by us. All operation and maintenance

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions Read and become familiar with these instructions before beginning installation. KSAIC020230 (208-230V) 24V Interface Kit for Ductless Outdoor Single Zone matched with Air Handler Installation Instructions Read and become familiar with these instructions before beginning installation.

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Model 1750A/ 1770A Dehumidifier Installation Instructions

Model 1750A/ 1770A Dehumidifier Installation Instructions Model 1750A/ 1770A Dehumidifier Installation Instructions Safety Instructions WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed

More information

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models T-Class Performance and rugged durability Commercial Split Systems Up to 20-Ton TSA/TPA Models Up to.7 EER Lennox units deliver comfort and control you can depend on Lennox proven design in air conditioners

More information

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles MINI-SPLIT STANDARD AIR CONDITIONERS SINGLE ZONE Mini-Split Standard systems utilize the same duct-free technology as Art Cool units in a streamlined, low profile design. Models are available in a variety

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

Variable Speed Convertible Air Handler 2 1/2 Ton

Variable Speed Convertible Air Handler 2 1/2 Ton Submittal Variable Speed Convertible Air Handler 2 1/2 Ton TEM6A0B30H21S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic.

More information

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3 HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3 INSTALLATION, OPERATION & MAINTENANCE MANUAL ARH-1 ARH-2 ARH-3 ARGO 2201 Dwyer Avenue Utica, NY 13501 www.argocontrols.com An ISO 9001-2000 Certified Company

More information

Daikin ENVi Thermostat installation overview

Daikin ENVi Thermostat installation overview Daikin ENVi Thermostat installation overview RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL Presenter s Name Presenter s Title Daikin ENVi system overview (web based thermostat) Slide 2 Daikin ENVi System Overview

More information

T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone

T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone Top-Discharge Ductless Split-System Condensing Units for R410 Refrigerant Capacities Multi-Zone Applications T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Units 9,000 12,000

More information

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the operation of reverse-cycle refrigeration (heat pumps) Explain

More information

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,

More information

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis (To be read in conjunction with labels TZ243 (Air-to-Air) & TZ245 (Water-to-Air) Date: 20 October 2015 Issue: 1 Index 1. Introduction...

More information

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 5 Ton Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These

More information

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models UP TO.7 EER Lennox units deliver comfort and control that you can depend on The latest offerings from Lennox represent a new design in air conditioners

More information

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES C US INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES Made in the USA by: Goodman Manufacturing Company, L.P. I0-240B 2550 North Loop West, Suite 400, Houston, TX 77092 www.goodmanmfg.com

More information

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard. American Standard Ductless Systems Product Catalog A Comfortable, Convenient Solution Built To A Higher Standard. American Standard Ductless Systems. Reliable Comfort, Precise Control. Designed and built

More information

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities R21C Packaged Terminal Air Conditioner (PTAC) The Right Fit for Comfort Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 kw 2.6 3.5 4.4 5.3 Model R21C Specifications and Performance

More information

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat CD-TB200-01 TB-200 Product Battery Powered Thermostat Description The Evolve Wireless Digital Thermostat/Temperature Sensor is designed to control the majority of HVAC systems when used in conjunction

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R22C/H Packaged Terminal Air Conditioner (PTAC) Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 The Right Fit for Comfort kw 2.6 3.5 4.4 5.3 Model R22C Packaged Terminal Heat Pump (PTHP)

More information

Otherwise, you can continue reading the file on the following pages.

Otherwise, you can continue reading the file on the following pages. If you d like to be able to print this file out to study off-line or use on the job, a printable version is available for an administrative fee of $3.97 USD. To download the unlocked file, click here.

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL SPECIFICATIONS B6VMMX TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers

More information

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING Emerson Inspire 1HDEZ-1521 Installation Instructions Thermostat/Interface Equipment Control TROUBLESHOOTING FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL

More information

SLIDE-IN HEATING COIL INSTALLATION MANUAL BULLETIN

SLIDE-IN HEATING COIL INSTALLATION MANUAL BULLETIN SLIDE-IN HEAING COIL INSALLAION MANUAL BULLEIN 30-030 ABLE OF CONENS Installation Specifications... 3 INRODUCION... 3 INSALLAION... 3 PIPING... 6 FREEZE PROECION... 6 WIRING AND CONROLS... 6 SARUP... 7

More information

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES 1-year warranty on parts and labor. 5-year compressor warranty. If Registered a 10 year limited parts warranty applies. Designed for maximum

More information

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS. PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

SSIC INSTALLATION, OPERATION & MAINTENANCE MANUAL

SSIC INSTALLATION, OPERATION & MAINTENANCE MANUAL SSIC2-0615 45W30-WG0720 SSIC INSTALLATION, OPERATION & MAINTENANCE MANUAL Section 1: INTRODUCTION Unit description... 2 Section 2: INSTALLATION Mounting... 2 Wiring... 2 Wiring diagram... 4 Section 3:

More information

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or

More information

Variable Speed Convertible Air Handler 4 Ton

Variable Speed Convertible Air Handler 4 Ton Submittal Variable Speed Convertible Air Handler 4 Ton TEM6A0D48H41S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These

More information

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016 PA C KA G E D H E AT P U M P LRP4HP Residential - R-40A Bulletin No. 07 November 06 P R O D U C T S P E C I F I C AT I O N S Supersedes October 06 SEER - 4.00 HSPF - 8.00 to 5 Tons Cooling Capacity -,600

More information

Service Step by Step Trouble-Shooting Check-List

Service Step by Step Trouble-Shooting Check-List WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:

More information

Multi zone Two, Three, Four and Five Zones

Multi zone Two, Three, Four and Five Zones MULTI SPLIT SYSTEM OUTDOOR UNITS SERVICE MANUAL Multi zone Two, Three, Four and Five Zones DC INVERTER MULTI ZONE OUTDOOR UNITS Revision A: ODMI E 1601 PDB55/2016 Model Numbers: YN020GMFI22M2D YN030GMFI22M3D

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

L CONNECTION NETWORK Commercial Controls

L CONNECTION NETWORK Commercial Controls L CONNECTION NETWORK Commercial Controls SIMPLIFIED, CENTRAL CONTROL Simplified Control for Your Facility The L Connection Network not only enhances comfort and energy-efficiency throughout your facilities,

More information

AG Series Electric Heaters

AG Series Electric Heaters AG Series Electric Heaters Installation, Operation and Maintenance Instructions Internal Auxililary Electric Heat 97B0005N03 Table of Contents Overview 3 Vertical Upflow Installation 4 Horizontal Installation

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information