1 65/8 TAG: M4PH4024A1000A SUBMITTAL 2.0 Ton Heat Pump Package Units M4PH4024A1000A Front 2413/16 89/16 23/8 181/2 219/ / /16 65/8 Hi./Lo. pressure service port 1/4 SAE 65/8 45/16 19/16 57/8 65/8 373/4 Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel Low voltage entrance 7/8 Dia. High voltage conn. 13/8 Dia. 113/16 Back View 3515/16 41/4 141/ /8 141/2 43/8 141/2 13/4 113/16 Bottom View Side supply air opening Side return air opeing 501/4 13/4
2 PRODUCT SPECIFICATIONS Specifications MODEL M4PH4024A1000A POWER CONNS. V/PH/HZ 208/230/1/60 MIN. BRCH. CIR. AMPACITY 13.7 BR. CIR. PROT. RTG. MAX. (AMPS) 20 SOUND POWER LEVEL [db(a)] 72 COMPRESSOR ROTARY. USED. SPEEDS 11 R.L. AMPS L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) 22 TYPE DRIVE. SPEEDS DIRECT 1 MOTOR HP 1/12 F.L. AMPS 0.68 OUTDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 9.79 TUBE SIZE (IN.) 9/32 INDOOR FAN TYPE Centrifugal DRIVE. SPEEDS DIRECT 3 VS. IN. WG. See Fan Performance Table MOTOR HP 1/4 F.L. AMPS 2.46 INDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 3.63 TUBE SIZE (IN.) 9/32 REFRIGERANT CONTROL ORIFICE REFRIGERANT LBS. R410 (O.D. UNIT) 5 LBS. 1 OZ. DIMENSIONS W X H X D CRATED (IN.) 523/8X257/8X385/8 WEIGHT SHIPPING (LBS.) 333 NET (LBS.) 326 Optional Heater Heater Kit Model Used MAYHTR1P08BKRB MAYHTR1P10BKRB Electric Heat (kw) Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity 208V 240V 208V 240V Fan Performance Table Motor Speed AIR FLOW PERFORMANCE M4PH4024A1000A External Static PressureInches W.C. (kpa) Low Medium High 0(0) (.02) (.05) (.07) (.10) (.12) (.15) (.17) 693
3 Features 25 ton capacities available Highefficiency 14 SEER ratings Architectural, antirust steel cabinets, tested to withstand 1,000hour salt spray Quiet horizontal discharge Highefficiency compressors operate smoothly, quietly, consistently Auxiliary electric heaters available as a field installed option: 5kW,8kW,10kW,15kW,20kW (available heater sizes vary depending on model tonnage) The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.
4 65/8 TAG: M4PH4030A1000A SUBMITTAL 2.5 Ton Heat Pump Package Units M4PH4030A1000A Front 2413/16 89/16 23/8 181/2 219/ / /16 65/8 Hi./Lo. pressure service port 1/4 SAE 65/8 45/16 19/16 57/8 65/8 373/4 Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel Low voltage entrance 7/8 Dia. High voltage conn. 13/8 Dia. 113/16 Back View 3515/16 41/4 141/ /8 141/2 43/8 141/2 13/4 113/16 Bottom View Side supply air opening Side return air opeing 501/4 13/4
5 PRODUCT SPECIFICATIONS Specifications MODEL M4PH4030A1000A POWER CONNS. V/PH/HZ 208/230/1/60 MIN. BRCH. CIR. AMPACITY 20.1 BR. CIR. PROT. RTG. MAX. (AMPS) 30 SOUND POWER LEVEL [db(a)] 74 COMPRESSOR ROTARY. USED. SPEEDS 11 R.L. AMPS L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) 22 TYPE DRIVE. SPEEDS DIRECT 1 MOTOR HP 1/6 MOTOR SPEED R.P.M. 825 F.L. AMPS 1.0 OUTDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 9.79 TUBE SIZE (IN.) 9/32 INDOOR FAN TYPE Centrifugal DRIVE. SPEEDS DIRECT 3 VS. IN. WG. See Fan Performance Table MOTOR HP 1/2 F.L. AMPS 4.1 INDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 3.63 TUBE SIZE (IN.) 9/32 REFRIGERANT CONTROL ORIFICE REFRIGERANT LBS. R410 (O.D. UNIT) 5 LBS. 5 OZ. DIMENSIONS W X H X D CRATED (IN.) 523/8X257/8X385/8 WEIGHT SHIPPING (LBS.) 353 NET (LBS.) 346 Optional Heater Heater Kit Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity Electric Heat (kw) Model Used 208V 240V 208V 240V MAYHTR1P08BKRB MAYHTR1P10BKRB MAYHTR1P15BKRB Fan Performance Table Motor Speed AIR FLOW PERFORMANCE M4PH4030A1000A External Static PressureInches W.C. (kpa) Low Medium High 0(0) (.02) (.05) (.07) (.10) (.12) (.15) (.17) 741
6 Features 25 ton capacities available Highefficiency 14 SEER ratings Architectural, antirust steel cabinets, tested to withstand 1,000hour salt spray Quiet horizontal discharge Highefficiency compressors operate smoothly, quietly, consistently Auxiliary electric heaters available as a field installed option: 5kW,8kW,10kW,15kW,20kW (available heater sizes vary depending on model tonnage) The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.
7 65/8 TAG: M4PH4036A1000A SUBMITTAL 3.0 Ton Heat Pump Package Units M4PH4036A1000A Front 2413/16 89/16 23/8 181/2 219/ / /16 65/8 Hi./Lo. pressure service port 1/4 SAE 65/8 45/16 19/16 57/8 65/8 373/4 Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel Low voltage entrance 7/8 Dia. High voltage conn. 13/8 Dia. 113/16 Back View 3515/16 41/4 141/ /8 141/2 43/8 141/2 13/4 113/16 Bottom View Side supply air opening Side return air opeing 501/4 13/4
8 PRODUCT SPECIFICATIONS Specifications MODEL M4PH4036A1000A POWER CONNS. V/PH/HZ 208/230/1/60 MIN. BRCH. CIR. AMPACITY 21.4 BR. CIR. PROT. RTG. MAX. (AMPS) 30 SOUND POWER LEVEL [db(a)] 75 COMPRESSOR ROTARY. USED. SPEEDS 11 R.L. AMPS L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) 22 TYPE DRIVE. SPEEDS DIRECT 1 MOTOR HP 1/6 MOTOR SPEED R.P.M. 825 F.L. AMPS 1.0 OUTDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 9.44 TUBE SIZE (IN.) 3/16 INDOOR FAN TYPE Centrifugal DRIVE. SPEEDS DIRECT 3 VS. IN. WG. See Fan Performance Table MOTOR HP 1/2 F.L. AMPS 4.1 INDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 3.63 TUBE SIZE (IN.) 9/32 REFRIGERANT CONTROL ORIFICE REFRIGERANT LBS. R410 (O.D. UNIT) 4 LBS. 14 OZ. DIMENSIONS W X H X D CRATED (IN.) 523/8X257/8X385/8 WEIGHT SHIPPING (LBS.) 357 NET (LBS.) 351 Optional Heater Heater Kit Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity Electric Heat (kw) Model Used 208V 240V 208V 240V MAYHTR1P08BKRB MAYHTR1P10BKRB MAYHTR1P15BKRB Fan Performance Table Motor Speed AIR FLOW PERFORMANCE M4PH4036A1000A External Static PressureInches W.C. (kpa) Low Medium High 0(0) (.02) (.05) (.07) (.10) (.12) (.15) (.17) 980
9 Features 25 ton capacities available Highefficiency 14 SEER ratings Architectural, antirust steel cabinets, tested to withstand 1,000hour salt spray Quiet horizontal discharge Highefficiency compressors operate smoothly, quietly, consistently Auxiliary electric heaters available as a field installed option: 5kW,8kW,10kW,15kW,20kW (available heater sizes vary depending on model tonnage) The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.
10 65/8 TAG: 3.5 Ton Heat Pump Package Units M4PH4042A1000A M4PH4042A1000A SUBMITTAL Front 331/16 103/8 23/8 Hi./Lo. pressure service port 1/4 SAE 221/ /2 311/16 65/8 47/16 19/16 81/16 65/8 1211/16 421/16 65/8 Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compapartment panel Low voltage entrance 7/8 Dia. High voltage conn. 13/8 Dia. 113/16 Back View 401/4 13/4 41/4 141/ /16 563/4 Bottom View 13/4 21/4 141/2 Side supply air opening 65/16 141/2 Side return air opeing
11 PRODUCT SPECIFICATIONS Specifications MODEL M4PH4042A1000AA POWER CONNS. V/PH/HZ 208/230/1/60 MIN. BRCH. CIR. AMPACITY 23.5 BR. CIR. PROT. RTG. MAX. (AMPS) 30 SOUND POWER LEVEL [db(a)] 78 COMPRESSOR SCROLL. USED. SPEEDS 11 R.L. AMPS L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) 235/8 TYPE DRIVE. SPEEDS DIRECT 1 MOTOR HP 1/3 F.L. AMPS 1.67 OUTDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) TUBE SIZE (IN.) 3/16 INDOOR FAN TYPE Centrifugal DRIVE. SPEEDS DIRECT 3 VS. IN. WG. See Fan Performance Table MOTOR HP 3/4 F.L. AMPS 2.8 INDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 6.43 TUBE SIZE (IN.) 9/32 REFRIGERANT CONTROL ORIFICE REFRIGERANT LBS. R410 (O.D. UNIT) 6 LBS. 10 OZ. DIMENSIONS H X W X D CRATED (IN.) 5815/16X343/16X423/8 WEIGHT SHIPPING (LBS.) 472 NET (LBS.) 463 Optional Heater Heater Kit Model Used Electric Heat (kw) Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity 208V 240V 208V 240V Fan Performance Table Motor Speed AIR FLOW PERFORMANCE M4PH4042A1000A External Static PressureInches W.C. (kpa) Low Medium High 0(0) (.02) (.05) (.07) (.10) (.12) (.15) (.17) 1133
12 Features 25 ton capacities available. Highefficiency 14 SEER ratings Architectural, antirust steel cabinets, tested to withstand 1,000hour salt spray Quiet horizontal discharge Highefficiency compressors operate smoothly, quietly, consistently Auxiliary electric heaters available as a field installed option: 5kW,8kW,10kW,15kW,20kW (available heater sizes vary depending on model tonnage) The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.
13 65/8 TAG: 4.0 Ton Heat Pump Package Units M4PH4048A1000A M4PH4048A1000A SUBMITTAL Front 331/16 103/8 23/8 Hi./Lo. pressure service port 1/4 SAE 221/ /2 311/16 65/8 47/16 19/16 81/16 65/8 1211/16 421/16 65/8 Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compapartment panel Low voltage entrance 7/8 Dia. High voltage conn. 13/8 Dia. 113/16 Back View 401/4 13/4 41/4 141/ /16 563/4 Bottom View 13/4 21/4 141/2 Side supply air opening 65/16 141/2 Side return air opeing
14 PRODUCT SPECIFICATIONS Specifications MODEL M4PH4048A1000A POWER CONNS. V/PH/HZ 208/230/1/60 MIN. BRCH. CIR. AMPACITY 26.9 BR. CIR. PROT. RTG. MAX. (AMPS) 40 SOUND POWER LEVEL [db(a)] 78 COMPRESSOR SCROLL. USED. SPEEDS 11 R.L. AMPS L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) 235/8 TYPE DRIVE. SPEEDS DIRECT 1 MOTOR HP 1/3 F.L. AMPS 1.67 OUTDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) TUBE SIZE (IN.) 3/16 INDOOR FAN TYPE Centrifugal DRIVE. SPEEDS DIRECT 3 VS. IN. WG. See Fan Performance Table MOTOR HP 3/4 F.L. AMPS 3.6 INDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 6.43 TUBE SIZE (IN.) 9/32 REFRIGERANT CONTROL ORIFICE REFRIGERANT LBS. R410 (O.D. UNIT) 6 LBS. 13 OZ. DIMENSIONS H X W X D CRATED (IN.) 5815/16X343/16X423/8 WEIGHT SHIPPING (LBS.) 472 NET (LBS.) 463 Optional Heater Heater Kit Model Used MAYHTR1P08BKRB MAYHTR1P10BKRB MAYHTR1P15BKRB MAYHTR1P20BKRB Electric Heat (kw) Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity 208V 240V 208V 240V Fan Performance Table Motor Speed AIR FLOW PERFORMANCE M4PH4048A1000A External Static PressureInches W.C. (kpa) Low Medium High 0(0) (.02) (.05) (.07) (.10) (.12) (.15) (.17) 1192
15 Features 25 ton capacities available Highefficiency 14 SEER ratings Architectural, antirust steel cabinets, tested to withstand 1,000hour salt spray Quiet horizontal discharge Highefficiency compressors operate smoothly, quietly, consistently Auxiliary electric heaters available as a field installed option: 5kW,8kW,10kW,15kW,20kW (available heater sizes vary depending on model tonnage) The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.
16 65/8 TAG: 5.0 Ton Heat Pump Package Units M4PH4060A1000A M4PH4060A1000A SUBMITTAL Front 331/16 103/8 23/8 Hi./Lo. pressure service port 1/4 SAE 221/ /2 311/16 65/8 47/16 19/16 81/16 65/8 1211/16 421/16 65/8 Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compapartment panel Low voltage entrance 7/8 Dia. High voltage conn. 13/8 Dia. 113/16 Back View 401/4 13/4 41/4 141/ /16 563/4 Bottom View 13/4 21/4 141/2 Side supply air opening 65/16 141/2 Side return air opeing
17 PRODUCT SPECIFICATIONS Specifications MODEL M4PH4060A1000A POWER CONNS. V/PH/HZ 208/230/1/60 MIN. BRCH. CIR. AMPACITY 34.6 BR. CIR. PROT. RTG. MAX. (AMPS) 50 SOUND POWER LEVEL [db(a)] 79 COMPRESSOR SCROLL. USED. SPEEDS 11 R.L. AMPS L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) 235/8 TYPE DRIVE. SPEEDS DIRECT 1 MOTOR HP 1/3 F.L. AMPS 1.67 OUTDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) TUBE SIZE (IN.) 9/32 INDOOR FAN TYPE Centrifugal DRIVE. SPEEDS DIRECT 3 VS. IN. WG. See Fan Performance Table MOTOR HP 3/4 F.L. AMPS 6.0 INDOOR COIL TYPE ROWS F.P.I FACE AREA (SQ. FT.) 6.43 TUBE SIZE (IN.) 9/32 REFRIGERANT CONTROL ORIFICE REFRIGERANT LBS. R410 (O.D. UNIT) 8 LBS. 13 OZ. DIMENSIONS H X W X D CRATED (IN.) 5815/16X343/16X423/8 WEIGHT SHIPPING (LBS.) 487 NET (LBS.) 479 Optional Heater Heater Kit Model Used MAYHTR1P08BKRB MAYHTR1P10BKRB MAYHTR1P15BKRB MAYHTR1P20BKRB Electric Heat (kw) Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity 208V 240V 208V 240V Fan Performance Table Motor Speed AIR FLOW PERFORMANCE M4PH4060A1000A External Static PressureInches W.C. (kpa) Low Medium High 0(0) (.02) (.05) (.07) (.10) (.12) (.15) (.17) 1479
18 Features 25 ton capacities available Highefficiency 14 SEER ratings Architectural, antirust steel cabinets, tested to withstand 1,000hour salt spray Quiet horizontal discharge Highefficiency compressors operate smoothly, quietly, consistently Auxiliary electric heaters available as a field installed option: 5kW,8kW,10kW,15kW,20kW (available heater sizes vary depending on model tonnage) The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.
Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:
Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR
More informationSubmittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:
Submittal Split System Cooling 4A7A6024J1000B Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install
More informationSubmittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:
Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More information4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8
Service Facts Split System Cooling 4TTB3048D1000B, 4TTB3060D1000B CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain
More information7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8
Service Facts Split System Cooling 4TTR3060D1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this
More information208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN
Service Facts Split System Cooling 4TTB3030D1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please
More informationService Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING
Service Facts Split System Cooling 4TTR6024A1000B 4TTR6024A1000B 208/230/1/60 18 20 CLIMATUFF - SCROLL 1-2 208/230/1/60 13.0-52 PROPELLER 27.6-1 DIRECT - 1 3200 1-1/8 835 208/230/1/60 0.74 SPINE FIN 1-24
More informationService Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION
Service Facts Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION 4TTB6-SF-3 UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED.
More information4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT
Service Facts Split System Cooling 4TTR6036B1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please
More informationService Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A
Service Facts Split System Cooling 3.0 Ton 4A7A6036J1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING Only qualified personnel should
More informationSplit System Cooling Product & Performance Data
Split System Cooling Product & Performance Data 2TTB0030-060A 2½ 5 Tons 22-1739-04 General Features Split System Cooling Units... The Evolution Continues 2TTB0 split systems represent a product that is
More information4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES
Service Facts Split System Cooling 4TTB18E1000A, 4TTB24E1000A 4TTBD1000B, 4TTB36D1000B 4TTB3-SF-1B CAUTION UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE
More informationService Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING
Service Facts Split System Cooling 4TTR6048A1000A 4TTR6048A1000A 208/230/1/60 28 45 CLIMATUFF - SCROLL 1-2 208/230/1/60 21.2-104 PROPELLER 27.6-1 DIRECT - 1 4260 1-1/5 825 208/230/1/60 1.0 SPINE FIN 1-24
More information4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT
Service Facts Split System Heat Pump 4A6H5042G1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this
More information4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES
Service Facts Split System Heat Pump 4A6H5049E1000B IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.
More informationProduct Data. Split System Heat Pump D-EN. February 2016
Product Data Split System Heat Pump 4A6H6018H1000A 4A6H6024H1000A 4A6H6030H1000A 4A6H6036H1000A 4A6H6042H1000A 4A6H6048H1000A 4A6H6060H1000A Note: Graphics in this document are for representation only.
More informationProduct Data. Split System Heat Pump B-EN. February A6H6024H1000A
Product Data Split System Heat Pump 4A6H6024H1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. February 2015 12-1202-1B-EN Product Specifications
More information208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/
Service Facts Split System Heat Pump 4TWB4024E1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.
More informationProduct Data. Split System Heat Pump A-EN. March 2016
Product Data Split System Heat Pump 4A6H4018G1000A 4A6H4024G1000A 4A6H4030G1000A 4A6H4036D1000A 4A6H4042G1000A 4A6H4048G1000A 4A6H4060G1000A Note: Graphics in this document are for representation only.
More informationProduct Data. Split System Cooling D-EN. August 2016
Product Data Split System Cooling 4A7A6018J1000A 4A7A6024J1000A 4A7A6030J1000A 4A7A6036J1000A 4A7A6042J1000A 4A7A6048J1000A 4A7A6049J1000A 4A7A6060J1000A 4A7A6061J1000A Note: Graphics in this document
More informationProduct Data. Split System Cooling H-EN. January 2017
Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000B 4TTR4025L1000B 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:
More informationProduct Data. Split System Cooling E-EN. November 2016
Product Data Split System Cooling 4TTR3018H1000N 4TTR3024H1000N 4TTR3030H1000N 4TTR3036H1000N 4TTR3042E1000N 4TTR3048E1000N 4TTR3060D1000N November 2016 22-1842-8E-EN Product Specifications Model No. (a)
More informationProduct Data. Split System Cooling A. November 2013
Product Data Split System Cooling 4TTR3018G1000A 4TTR3024G1000A 4TTR3030G1000A 4TTR3036E1000A 4TTR3042D1000A 4TTR3048D1000A 4TTR3060D1000A November 2013 22-1842-8A Product Specifications Model No. (a)
More informationSplit System Cooling Product Data XB 1000
Split System Cooling Product TTB-D-7 XB 1000 TTB012-060C PUB. NO. 22-1689-02-797 (EN) General Features Split System Cooling Units... Designed With Your Needs In Mind. TTB Split systems represent a new
More informationSubmittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:
Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationSubmittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:
Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationProduct Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A
Product Data Side Discharge AC Models For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after
More informationSubmittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:
Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationProduct Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A
Product Data Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A Note: Graphics in this document are for representation only.
More informationVariable Speed Convertible Air Handler 2 1/2 Ton
Submittal Variable Speed Convertible Air Handler 2 1/2 Ton TEM6A0B30H21S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic.
More informationProduct Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A
Product Data 22178001 2/4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ 5 Ton R22/R410A 2/4YCX3018A through 2/4YCX3060A Mar. 03, 2006 2006 American Standard inc. All Rights
More informationProduct Data. Split System Heat Pump
Product Data Split System Heat Pump 4TWR5018H1000A 4TWR5019H1000A 4TWR5024H1000A 4TWR5030H1000A 4TWR5036H1000A 4TWR5042H1000A 4TWR5048H1000A 4TWR5060H1000A Note: Graphics in this document are for representation
More informationVariable Speed Convertible Air Handler 4 Ton
Submittal Variable Speed Convertible Air Handler 4 Ton TEM6A0D48H41S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These
More informationProduct Data Split System Cooling
Product Data Split System Cooling 4TTR3018H1000N 4TTR3024H1000N 4TTR3030H1000N 4TTR3036H1000N 4TTR3042E1000N 4TTR3043A1000N 4TTR3048E1000N 4TTR3049A1000N 4TTR3060D1000N August 2017 22-1842-8H-EN Outline
More informationVariable Speed Convertible Air Handler 5 Ton
Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These
More informationService Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A
Service Facts Split System Heat Pump 4A6H5019H1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING Only qualified personnel should install
More informationSubmittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:
Submittal Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified
More informationProduct catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4
Product catalog Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4 Features and Benefits Outdoor unit 4TTB Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
More information36,000-62,000 BTUH Nominal Capacity
36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left
More informationUnit Features & Benefits RQPM/RQRM Series
2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable
More information2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil
Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More information4YCC3048A3096A /3/ /
YCC3048A-SPEC-3A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS SPECIFICATIONS 4YCC3048A3075/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power
More informationMulti-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers
Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-07 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-05 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners
More informationModular Multi-position Air Handler
Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design
More informationPRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /
YCC3036A-SPEC-1E TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3036A1064/75/96A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power
More informationVertical Upflow Horizontal Left Air Handlers
Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with
More informationLGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.
Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The
More informationCorp L2 Revised
Service Literature Corp. 08-L Revised 0-07 ZCA & ZCB SERIES, 4, 5 and 6 ton 0.6 to.kw ZCA06, 048, 060, 07 & ZCB06, 048, 060, 074 The ZCA packaged electric cooling units are available in standard cooling
More informationPRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /
YCC3048-SPEC-1B TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3048A107/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power
More informationSPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:
4YCC3060A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]
More information2YCC3060A1120A /1/ / YCC3060A1096A /1/ /
YCC30A-SPEC-1D TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING SPECIFICATIONS 2/4YCC30A1096/120A PRODUCT SPECIFICATIONS MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input
More information4YCC3036A1075B /1/ / YCC3036A1064B /1/ /
4YCC3036A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation
More informationSPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning
SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A7 2014 American Standard Heating & Air Conditioning PUB. NO. 12-1348-02 August 2014 Features and Benefits DURATION 2-stage scroll compressor Efficiency up
More informationSPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning
SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationAMERICAN STANDARD 14 MODELS 4A7B E
SPLIT SYSTEM COOLING 1 1 / 2 5 ton AMERICAN STANDARD 14 MODELS 4A7B4018-60E PUB. NO. 12-1290-02 June 2009 Features and Benefits DURaTION compressor Efficiency up to 16.0 SEER All aluminum Spine Fin coil
More informationSplit System Heat Pump Product & Performance Data
SS-PRC007-EN Split System Heat Pump Product & Performance Data XL14i 2TWX4018-060 1½ 5 Tons PUB. NO. 22-1750-05 Features and Benefits Climatuff compressor Efficiency up to 15.25 SEER and 9.6 HSPF All aluminum
More informationSPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A
SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A6018-61 PUB. NO. 12-1350-03 February 2015 Features and Benefits DURATION compressor Efficiency up to 17.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationDRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION
CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner
More informationSubmittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:
Submittal Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A1060A SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing
More information3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION
AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant
More informationSplit System Cooling Product Data
Split System Cooling Product XB14 4TTB4 1 1 /2-5 Tons (018E - 061E) PUB. NO. 22-1833-08 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners
More informationProduct Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A
Product Data 22-1807-09 4WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 06/14 2014 Trane Pub. No. 22-1807-09 It's Hard to Stop a Trane. Single Packaged Electric
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
More informationPackaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE
Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature
More informationSplit System Cooling Product Data
Split System Cooling Product Data XL18i 4TTX8024, 036, 048 & 060 2, 3, 4 & 5 Tons PUB. NO. 22-1885-02 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE
More informationProduct Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.
Product Data 22179614 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2 5 Ton R410A 2013 Trane Pub. No. 22179614 It's Hard to Stop a Trane. Single Packaged Cooling System Trane offers
More informationSPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning
SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A4018-24C/30-060B 2009 American Standard Heating & Air Conditioning PUB.. 12-1173-04 April 2009 Features and Benefits Duration compressor Efficiency
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product XR15 4TWR5 1 1 /2-5 Tons PUB. NO. 22-1832-13 Features and Benefits CLIMATUFF compressor Efficiency up to 17.0 SEER and 9.0 HSPF All aluminum SPINE FIN coil WEATHERGUARD fasteners
More informationSplit System Cooling Product Data
Split System Cooling Product Data XB14 4TTB4 1 1 / 2-5 Tons (018E - 061E) PUB. NO. 22-1833-10 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DT4BD Series M120 Product Line High Efficiency R-410A Heat Pump 13 SEER 1.5-5 Ton 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product XR15 4TWR5 1 1 /2-5 Tons PUB. NO. 22-1832-10 Features and Benefits CLIMATUFF compressor Efficiency up to 17.0 SEER and 9.0 HSPF All aluminum SPINE FIN coil WEATHERGUARD fasteners
More informationProduct Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014
Product Data Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton 4WCC4024A1000A 4WCC4030A1000A 4WCC4036A1000A 4WCC4042A1000A 4WCC4048A1000A 4WCC4060A1000A Note: Graphics in this document are for representation
More informationRHEEM Split Systems Condensers All submitted condensers meet the 15 SEER minimum All submitted condensers meet the 208/230V specification All submitted condensers contain enhanced mufflers to help dissipate
More informationSplit System Cooling Product & Performance Data
Split System Cooling Product & Performance Data Three Phase 2TTA3048-060A3 4 5 Tons PUB. NO. 22-1770-03 Features and Benefits All aluminum Spine Fin coil Durable base, fast complete drain, weather proof
More informationSEER 1½
Product Data 22-1782-13 4TCC3018 through 4TCC3060 Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 2013 Trane Pub. No. 22-1782-13 07/13 It's Hard to Stop a Trane. Single Packaged Cooling System
More informationProduct Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.
Product Data 22-1789-06 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A 2007 Trane Pub. No. 22-1789-06 Single Packaged Electric Heat Pump System Trane offers a
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-06 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant
More informationSubmittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006
Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba
More informationSplit System Cooling Product Data
Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-14-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant
More informationProduct Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006
Product Data 22-1782-01 4TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A Mar. 03, 2006 2006 American Standard inc. All Rights Reserved Pub. No. 22-1782-01 It's Hard
More informationProduct Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A
Product Data 22-1799-20-EN 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, 60-120 MBTU R-410A 2014Trane Pub. No. 22-1799-20-EN It's Hard to Stop a Trane. Packaged Convertible
More informationSplit System Cooling Product Data
Split System Cooling Product Data XB16 4TTB6 1 1 / 2-5 Tons PUB. NO. 22-1888-01 Features and Benefits Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners QUICK-SESS cabinet, service
More information2 shp 13 lc 1 36 t - 1 a
HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationKlimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More informationSplit System Cooling Product Data
Split System Cooling Product Data Three Phase 4TTA3 3 5 Tons PUB. NO. 22-1791-16-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant
More information2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½
Cooling/Heat Pump Convertible Air Handlers 2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ 5 Ton Preliminary PUB. NO. 22-1777-04 Features and
More information