Instructions for use. Turbine handpieces with LED TE-97 LQ / TE-98 LQ Roto Quick coupling with generator RQ-53 / RQ-54

Size: px
Start display at page:

Download "Instructions for use. Turbine handpieces with LED TE-97 LQ / TE-98 LQ Roto Quick coupling with generator RQ-53 / RQ-54"

Transcription

1 Instructions for use Turbine handpieces with LED TE-97 LQ / TE-98 LQ Roto Quick coupling with generator RQ-53 / RQ-54 Turbine handpieces without light TE-95 BC / TE-95 RM TE-97 / TE-97 BC / TE-97 RM TE-98 / TE-98 BC / TE-98 RM

2 Contents Symbols in the Instructions for use (4), on the turbine handpiece / Roto Quick coupling / packaging (5) 1. Introduction General (6 7), Skilled application (8), Intended use (9), Responsibility of the manufacturer (10) 2. Safety notes General (11 13), Turbine handpiece with LED / Roto Quick coupling with generator (14 16) 3. Product description Roto Quick coupling (17), Turbine handpiece with Roto Quick connection (18 19), Turbine handpiece with Borden (BC) connection (20), Turbine handpiece with Ritter-Midwest (RM) connection (21) 4. Operation Assembly/Removal (22 26), To change rotary instrument (28 29), Test run (30 31) 2

3 Contents 5. Hygiene and maintenance General (32 33), Pre-disinfection (34), Manual cleaning (35 39), Manual disinfection (40), Mechanical cleaning/disinfection/lubrication (41), Oil service (42 47), Sterilization and storage (48 49) 6. Maintenance Correction of malfunctions (50 51), Replacing the rotor (52 53), Cleaning/Replacing the water filter (54 55), Replacing the generator (56 57), Replacing the O-rings (58) 7. W&H Accessories and spare parts Technical data General (62), Turbine handpiece (63 65), Roto Quick coupling (66) 9. Recycling and disposal...67 Explanation of warranty terms...68 Authorized W&H service partners

4 Symbols in the Instructions for use WARNING! (risk of injury) ATTENTION! (to prevent damage occurring) General explanations, without risk to persons or objects Do not dispose of with domestic waste 4

5 Symbols on the turbine handpiece / Roto Quick coupling / packaging CE 0297 from the manufacturer Thermo washer disinfectable REF SN Catalogue number Serial number Data Matrix Code for product identification, e.g., in hygiene/maintenance process Sterilizable up to the stated temperature Type B applied part (not suitable for direct cardiac application) Date of manufacture UL Component Recognition Mark indicates compliance with Canadian and U.S. requirements 5

6 1. Introduction General Customer satisfaction has absolute priority in the W&H quality policy. This W&H product has been developed, manufactured and subjected to final inspection according to legal regulations, quality norms and industry standards. For your safety and the safety of your patients Prior to initial use please read the Instructions for use. These explain how to use your W&H product and guarantee a smooth and efficient operation. Qualifications of the user We have based our development and design of the turbine handpiece / Roto Quick coupling on the dentists, dental hygienists, dental employees (prophylaxis) and dental assistants target group. 6

7 1. Introduction General Production according to EU Directive The turbine handpiece / Roto Quick coupling is a medical product according to the EU Directive 93/42/EEC. Operating malfunction of the turbine handpiece / Roto Quick coupling > Correct the malfunction as described in the»maintenance«section on pages 50 and 51. > If it proves impossible to correct the malfunction, please contact an authorized W&H service partner (see page 69). > Repairs must only be undertaken by an authorized W&H service partner. 7

8 1. Introduction Skilled application Skilled application The turbine handpiece / Roto Quick coupling is intended only for skilled application in the dental or medical field according to its purpose of use in compliance with the valid health and safety at work regulations, the valid accident prevention regulations as well as in compliance with these Instructions for use. The turbine handpiece / Roto Quick coupling should be prepared for use and maintained by staff who have been trained in procedures for infection control, personal safety and patient safety. Improper use, (e.g., through poor hygiene and maintenance), non-compliance with our instructions or the use of accessories and spare parts which are not approved by W&H, invalidates all claims under warranty and any other claims. 8

9 1. Introduction Intended use Intended use The dental turbine handpiece is intended for the following applications: Removal of decayed materials, cavities and crown preparation, removal of fillings, finishing of tooth and restoration surfaces. The Roto Quick coupling is intended for the following applications: Connector for media transfer (air, water, electricity and light) between the supply hose and the dental unit and air driven motors. Misuse may damage the turbine handpiece / Roto Quick coupling and hence cause risks and hazards for patient, user and third parties. 9

10 1. Introduction Responsibility of the manufacturer Responsibility of the manufacturer The manufacturer can only accept responsibility for the safety, reliability and performance of the turbine handpiece / Roto Quick coupling when it is used in compliance with the following directions: > The turbine handpiece / Roto Quick coupling must be used in accordance with these Instructions for use. > Only the components approved by the manufacturer may be replaced (rotor, O-rings, generator and water filter). > Repairs must only be undertaken by an authorized W&H service partner (see page 69). 10

11 2. Safety notes General > The operation of the turbine handpiece / Roto Quick coupling is permitted only on dental units which correspond to the standards IEC (EN ) and IEC (EN ). > Use only the supply hoses as specified by EN ISO > Use only the filtered, oil-free and cooled air supplied by dental compressors for drive air. > Run the rinse function for the dental unit once per day. > Always ensure the correct operating conditions and cooling function. > Always ensure that sufficient and adequate cooling is delivered and ensure adequate suction. > In case of coolant supply failure, the turbine handpiece must be stopped immediately. 11

12 2. Safety notes General > Check the turbine handpiece / Roto Quick coupling for damage and loose parts each time before using (e.g., push-button / leak tightness between the Roto Quick coupling and supply hose). > Do not operate the turbine handpiece / Roto Quick coupling if it is damaged / leaking. > Perform a test run each time before using. > Never touch the push-button of the turbine handpiece during operation or while it is still running down. > Do not use the turbine handpiece if there are soft tissue wounds in the mouth. The air pressure can cause septic substances to enter the tissue or trigger embolisms. > Do not touch the soft tissue with the turbine handpiece head (risk of burning due to the push-button heating up)! > Avoid overheating at the treatment site. 12

13 2. Safety notes General Hygiene and maintenance prior to initial use The turbine handpiece / Roto Quick coupling is in a clean condition and sealed in PE-film when delivered. > Lubricate the turbine handpiece. > Sterilize the turbine handpiece and the nozzle cleaner. > Oil service page 42 > Sterilization page 48 13

14 2. Safety notes TE-97 LQ / TE-98 LQ / RQ-53 / RQ-54 The turbine handpiece TE-97 LQ / TE-98 LQ may only be used with the Roto Quick coupling RQ-53 / RQ-54. > Avoid contact between LED and soft tissue (risk of burning due to the LED heating up). > Do not use the turbine handpiece as light sensor. > Do not look directly into the LED. The turbine handpiece / Roto Quick coupling is not suitable for use in oxygen enriched atmospheres. 14

15 2. Safety notes TE-97 LQ / TE-98 LQ / RQ-53 / RQ-54 Danger zones M and G In accordance with IEC / ANSI/AAMI ES , the turbine handpiece / Roto Quick coupling is not suitable for use in potentially explosive atmospheres or with potentially explosive mixtures of anaesthetic substances containing oxygen or nitrous oxide. Zone M is defined as a»medical environment«and constitutes the part of a room in which potentially explosive atmospheres may form due to the use of anaesthetics or medical antiseptics and antibacterial soaps; such atmospheres are typically localized and temporary. Zone M comprises a truncated pyramid below the operating table which is tilted outwards at a 30 angle. Zone G, also known as an»enclosed medical gas system«, does not necessarily include areas enclosed around all sides, in which explosive mixtures are continuously or temporarily generated, directed or used in small quantities. 15

16 2. Safety notes TE-97 LQ / TE-98 LQ / RQ-53 / RQ-54 Risks due to electromagnetic fields The functionality of implantable systems, such as cardiac pacemakers and implantable cardioverter defibrillator (ICD) can be affected by electric, magnetic and electromagnetic fields. > Find out if patient and user have implanted systems before using the product and consider the application. > Weigh the risks and benefits. > Keep the product away from implanted systems. > Make appropriate emergency provisions and take immediate action on any signs of ill-health. > Symptoms such as raised heartbeat, irregular pulse and dizziness can be signs of a problem with a cardiac pacemaker or ICD. 16

17 3. Product description RQ-53 / RQ-54 Roto Quick coupling with generator O-rings Electrical contacts Nut Gasket Water filter with resuction stop Generator Connections Drive air Water Spray air Exhaust 17

18 3. Product description TE-97 LQ / TE-98 LQ Turbine handpiece with LED and Roto Quick connection Push-button Spray nozzles LED Sheath Nozzle cleaner Roto Quick connection The turbine handpiece TE-97 LQ / TE-98 LQ may only be used with the Roto Quick coupling RQ-53 / RQ

19 3. Product description TE-97 / TE-98 Turbine handpiece without light and Roto Quick connection Push-button Spray nozzles Sheath Nozzle cleaner Roto Quick connection 19

20 3. Product description TE-95 BC / TE-97 BC / TE-98 BC Turbine handpiece without light and Borden (BC) connection Push-button Spray nozzles Sheath Nozzle cleaner Gasket Water filter with resuction stop Supply hose Connections Drive air Water 20

21 3. Product description TE-95 RM / TE-97 RM / TE-98 RM Turbine handpiece without light and Ritter-Midwest (RM) connection Push-button Spray nozzles Sheath Nozzle cleaner Gasket Water filter with resuction stop Supply hose Connections Drive air Water Spray air Exhaust 21

22 4. Operation Assembly/Removal RQ-53 / RQ-54 Insert the Roto Quick coupling into the apertures of the supply hose. Screw the union nut on. Check the leak tightness (see page 23) between the Roto Quick coupling and supply hose. or Unscrew the union nut. Remove the Roto Quick coupling from the supply hose. 22

23 4. Operation Assembly/Removal Check leak tightness between Roto Quick coupling and supply hose > Block the water outlet at the tip of the Roto Quick coupling with a piece of rubber or leather. > Switch on the water. No water should leak out between the Roto Quick coupling and the supply hose after 10 seconds of blockage. In the event of malfunctions (e.g., vibrations, unusual noise, leaks), stop the Roto Quick coupling immediately. > Correct the malfunction as described in the»maintenance«section on pages 50 and 51. > If it proves impossible to correct the malfunction, please contact an authorized W&H service partner (see page 69). > Repairs must only be undertaken by an authorized W&H service partner. 23

24 4. Operation Assembly/Removal Do not assemble or remove the turbine handpiece during the operation! TE-97 LQ / TE-98 LQ / TE-97 / TE-98 Push the turbine handpiece onto the Roto Quick coupling. Check the secure hold of the Roto Quick coupling. or Pull the retention sleeve of the Roto Quick coupling back. Remove the turbine handpiece by pulling in an axial direction. 24

25 4. Operation Assembly/Removal Do not assemble or remove the turbine handpiece during the operation! TE-95 BC / TE-97 BC / TE-98 BC Insert the turbine handpiece into the apertures of the supply hose. Screw the union nut on. or Unscrew on the union nut. Remove the turbine handpiece from the supply hose. 25

26 4. Operation Assembly/Removal 26 Do not assemble or remove the turbine handpiece during the operation! TE-95 RM / TE-97 RM / TE-98 RM Insert the turbine handpiece into the apertures of the supply hose. Screw the union nut on. Check the leak tightness between the turbine handpiece and supply hose. or Unscrew on the union nut. Remove the turbine handpiece from the supply hose.

27 27

28 4. Operation To change rotary instrument Rotary instruments > Use only rotary instruments which are in perfect condition and which have shanks that meet the requirements of the ISO standard. Follow the operating instructions of the manufacturer. > Insert the rotary instrument only when the turbine handpiece is stationary. > Never touch the rotary instrument which is still rotating. > Do not activate the push-button of the turbine handpiece during operation or slowing down. This leads to detachment of the rotary instrument and/or makes the push-button hot (risk of injury). 28

29 4. Operation To change rotary instrument Insert the rotary instrument. Activate the push-button, at the same time insert the rotary instrument until back stop (a). Check secure location by applying slight axial tension. or Activate the push-button and remove the rotary instrument. 29

30 4. Operation Test run Do not hold the turbine handpiece at eye level. > Insert the turbine handpiece with Roto Quick connection on the Roto Quick coupling on the supply hose. or > Screw the turbine handpiece with BC / RM connection onto the supply hose. > Insert the rotary instrument. > Start the turbine handpiece. 30

31 4. Operation Test run In the event of malfunctions (e.g., vibrations, unusual noise, overheating, coolant failure or leakage, discoloration of the LED) stop the turbine handpiece / Roto Quick coupling immediately. > Correct the malfunction as described in the»maintenance«section on pages 50 and 51. > If it proves impossible to correct the malfunction, please contact an authorized W&H service partner (see page 69). > Repairs must only be undertaken by an authorized W&H service partner. 31

32 5. Hygiene and maintenance General Follow your country-specific directives, standards and guidelines for cleaning, disinfection and sterilization. > You can process the turbine handpiece manually or mechanically. > Wear protective clothing. > Remove the turbine handpiece from the Roto Quick coupling / supply hose. > Remove the rotary instrument. Nozzle cleaner > Clean and disinfect the nozzle cleaner in an ultrasonic bath or disinfection bath. > Sterilize the nozzle cleaner following manual cleaning and disinfection. 32

33 5. Hygiene and maintenance General Turbine handpiece > Clean and disinfect the turbine handpiece immediately after every treatment, to flush out any liquid (such as blood, saliva etc.) and to prevent settling on the internal parts. > After manual cleaning, disinfection and lubrication you must carry out a final thermal disinfection (unwrapped) or sterilization (wrapped) in a class B or S steam sterilizer (according to EN 13060). > Sterilize the turbine handpiece following manual or mechanical cleaning, disinfection and lubrication. Roto Quick coupling > Clean and disinfect the Roto Quick coupling immediately after every treatment. > Lubricate the generator of the Roto Quick coupling once a month. The Roto Quick coupling is not approved for thermo washer disinfection and sterilization. 33

34 5. Hygiene and maintenance Pre-disinfection > If heavily soiled: Clean first with disinfectant cloths. Only use disinfectants that have no protein-fixing effects. 34

35 5. Hygiene and maintenance Manual cleaning Manual cleaning internal and external Rinse and brush off under demineralized water (< 38 C / < 100 F). Remove any liquid residues (absorbent cloth, blow dry with compressed air). Do not place the turbine handpiece / Roto Quick coupling in liquid disinfectant or in an ultrasonic bath. 35

36 5. Hygiene and maintenance Manual cleaning Cleaning of the spray nozzles > Clean spray nozzles carefully with the nozzle cleaner to remove dirt and deposits. Cleaning of the coolant channel > Blow through the coolant channel with the air syringe. 36

37 5. Hygiene and maintenance Manual cleaning In case of blocked spray nozzles In case of blocked coolant channel > Correct the malfunction as described in the»maintenance«section on pages 50 and 51. > If it proves impossible to correct the malfunction, please contact an authorized W&H service partner (see page 69). > Repairs must only be undertaken by an authorized W&H service partner. 37

38 5. Hygiene and maintenance Manual cleaning TE-97 LQ / TE-98 LQ Cleaning of the LED Avoid scratching of the LED! Wash the LED with cleaning fluid and a soft cloth. 38

39 5. Hygiene and maintenance Manual cleaning Blow the LED dry with air syringe or dry it carefully with a soft cloth. Carry out a visual inspection after each cleaning process. Do not use the turbine handpiece if the LED is damaged and contact an authorized W&H service partner (see page 69). 39

40 5. Hygiene und Pflege Manual disinfection W&H recommends wiping down with disinfectant. > Use only disinfectants which do not contain chlorine and which are certified by officially recognized institutes. > Note the manufacturer s specifications for the use of the disinfectants. 40

41 5. Hygiene and maintenance Mechanical cleaning/disinfection/lubrication Turbine handpiece Mechanical cleaning internal and external and lubrication W&H recommends mechanical cleaning and lubrication with W&H Assistina 3x3. > Follow the instructions in the Assistina Instructions for use. Mechanical cleaning and disinfection internal and external The turbine handpiece can be cleaned and disinfected in a thermo washer disinfector. > Note the manufacturer s specifications on equipment, cleaning agents and detergents. > Make sure, that the turbine handpiece is completely dry internally and externally after thermo washer disinfection. Remove any liquid residues with compressed air. > Lubricate the dry turbine handpiece immediately after thermo washer disinfection. 41

42 5. Hygiene and maintenance Daily oil service Recommended lubrication cycles > Essential after every internal cleaning > Before each sterilization or > After 30 minutes of use or at least once daily With W&H Service Oil F1, MD-400 > Follow the instructions on the oil spray can and on the packaging. or 42

43 5. Hygiene and maintenance Daily oil service With W&H Assistina > See Instructions for use of Assistina. 43

44 5. Hygiene and maintenance Weekly oil service Lubricate the chucking system With W&H Service Oil F1, MD-400 > Fit the spray cap REF onto the spray can. > Hold the turbine handpiece firmly. > Press the tip of the spray nozzle firmly into the chucking system. > Spray for approx. 1 second. or 44

45 5. Hygiene and maintenance Weekly oil service Only with W&H Assistina 301 > Fit the adaptor REF onto the maintenance attachment. Direct exit nozzle downwards. > Press the turbine handpiece with the chucking system onto the adaptor from below. > Start the Assistina. > Press the chucking system onto the adaptor for approx. 10 seconds. > Remove the turbine handpiece from the adaptor. > Close the cover of the Assistina and allow it to run for the remainder of the maintenance cycle (approx. 25 seconds). 45

46 5. Hygiene and maintenance Monthly oil service RQ-53 / RQ-54 Lubricate the generator With W&H Service Oil F1, MD-400 > Fit the spray cap REF onto the spray can. > Hold the Roto Quick coupling firmly. > Press the tip of the spray nozzle firmly into the generator. > Spray for approx. 1 second. or With W&H Assistina > See Instructions for use of Assistina. 46

47 5. Hygiene and maintenance Test run following oil service Place the turbine handpiece with the head downwards. Start the turbine handpiece for 30 seconds to remove excessive oil. Repeat the complete hygiene and maintenance process at any sign of dirt re-emerging. Wipe the turbine handpiece / Roto Quick coupling with gauze or soft cloth. 47

48 5. Hygiene and maintenance Sterilization and storage W&H recommends sterilization according to EN 13060, class B. > Note the instructions of the unit manufacturer. > Clean, disinfect and lubricate the turbine handpiece before sterilizing. > Wrap the turbine handpiece and the accessory in sterile goods packing according to EN > Make sure, that you only remove dry sterile goods. > Store sterile goods dust-free and dry. The standard ISO / ISO stipulates a durability of at least 250 sterilization cycles. In the case of the turbine handpiece from W&H, we recommend you to have a regular service carried out after 1,000 sterilization cycles or one year. 48 The Roto Quick coupling is not approved for sterilization. The Roto Quick coupling can be kept on the supply hose.

49 5. Hygiene and maintenance Sterilization and storage Approved sterilization procedures Follow your country-specific directives, standards and guidelines. > Steam sterilization class B with sterilizers in accordance with EN Sterilization holding time a minimum of 3 minutes at 134 C (273 F). or > Steam sterilization class S with sterilizers in accordance with EN The sterilizer manufacturer must give its express approval for the sterilization of turbine handpieces. Sterilization holding time a minimum of 3 minutes at 134 C (273 F). 49

50 6. Maintenance Operating malfunction Malfunction Correction of malfunctions Insufficient power > Check the connection between the turbine handpiece / Roto Quick coupling and supply hose > Check the operating pressure > Perform an oil service > Check/replace the O-rings > Replace the rotor Insufficient/no cooling > Check the operating pressure > Clean the spray nozzles > Clean/replace the water filter > Check/replace the O-rings 50

51 6. Maintenance Operating malfunction Malfunction Inadequate hold of rotating instrument Insufficient/no light Attach another LED turbine handpiece to determine whether the LED on the turbine handpiece or the generator in the Roto Quick coupling is defective. Correction of malfunctions > Perform an oil service > Replace the push-button > Replace the rotor > Check the operating pressure > Perform an oil service > Lubricate the generator > Replace the generator 51

52 6. Maintenance Replacing the rotor Unscrew the push-button using the hexagon wrench. Push the rotor out of the turbine head using the tip of a pair of tweezers. Clean the inside of the turbine head and the push-button with a cloth soaked in isopropyl alcohol. Blow dry the push-button and the turbine head with compressed air. Place the new rotor into the push-button. Place the rotor with the push-button into the turbine head. 52

53 6. Maintenance Replacing the rotor Screw the push-button onto the turbine head. Tighten the push-button using the hexagon wrench. Check free running of the chucking system. Activate the push-button and remove the mandrel. > Perform a test run. > Repeat the complete hygiene and maintenance process. 53

54 6. Maintenance Cleaning/Replacing the water filter RQ-53 / RQ-54 TE-95 BC / RM, TE-97 BC / RM, TE-98 BC / RM Remove the gasket. Pull the water filter out using a pair of tweezers. Clean the water filter (see page 55). or Insert the new water filter. Slide on the gasket. 54

55 6. Maintenance Cleaning/Replacing the water filter Cleaning the water filter Clean outlets carefully with the nozzle cleaner to remove dirt and deposits. The water filter can be cleaned in an ultrasonic bath. > Repeat the complete hygiene and maintenance process. 55

56 6. Maintenance Replacing the generator RQ-53 / RQ-54 Remove the gasket. Pull the generator out. 56

57 6. Maintenance Replacing the generator Position the generator with the mark aligned with the notch on the Roto Quick coupling. Insert the new generator until back stop. Slide on the gasket. Clean and disinfect the Roto Quick coupling. 57

58 6. Maintenance Replacing the O-rings RQ-53 / RQ-54 > Replace damaged or leaking O-rings immediately. > Always replace all the O-rings. > Do not use a sharp tool! Squeeze the O-ring between your thumb and index finger so that it forms a loop. Pull off the O-ring. Push the new O-ring on in its place. 58

59 7. W&H Accessories and spare parts Use only original W&H accessories and spare parts or accessories approved by W&H. Suppliers: W&H partners REF Description RQ-53 RQ Nozzle cleaner x x O-ring set (2x large, 1x small) x x BC gasket x RM gasket x Generator x Generator x Water filter with resuction stop x Water filter with resuction stop x REF Description 301 3x2 3x3 301 Assistina x Assistina 3x2 (MB-200) x Assistina 3x3 (MB-300) x Adaptor for RQ-53 / TE-95 BC / TE-97 BC / TE-98 BC x x Base adaptor for RQ-54 / TE-95 RM / TE-97 RM / TE-98 RM x Adaptor for TE-97 LQ / TE-98 LQ / TE-97 / TE-98 x Adaptor for chucking system x Adaptor for TE-95 BC / TE-97 BC / TE-98 BC x 59

60 7. W&H Accessories and spare parts REF Description TE-97 TE-97 LQ TE-98 TE-98 LQ Service Oil F1, MD-400 (6 pcs) x x x x Nozzle cleaner x x x x Spray cap with nozzle x x x x Push-button x x Push-button x x Rotor with hexagon wrench x x Rotor with hexagon wrench x x Torque wrench x x x x 60

61 7. W&H Accessories and spare parts REF Bezeichnung TE-95 BC TE-97 BC TE-98 BC TE-95 RM TE-97 RM TE-98 RM Service Oil F1, MD-400 (6 pcs) x x x x x x Nozzle cleaner x x x x x x Spray cap with nozzle x x x x x x Push-button x x x x Push-button x x BC gasket x x x RM gasket x x x Rotor with hexagon wrench x x Rotor with hexagon wrench x x Rotor with hexagon wrench x Rotor with hexagon wrench x Torque wrench x x x x x x Water filter with resuction stop x x x Water filter with resuction stop x x x 61

62 8. Technical data General The power and speed depend on the quality of the supply hose used and may differ from the specified value. Temperature information Temperature of the turbine handpiece at the operator side: maximum 55 C (131 F) Temperature of the turbine handpiece at the patient side: maximum 50 C (122 F) Temperature of the working part (rotary instrument): maximum 41 C (105.8 F) Physical characteristics Temperature for storage and transport: Air humidity for storage and transport: Ambient temperature during operation: Air humidity during operation: -40 C to +70 C (-40 F to +158 F) 8 % to 80 % (relative), non condensing +10 C to +35 C (+50 F to +95 F) 15 % to 80 % (relative), non condensing 62

63 8. Technical data Turbine handpiece TE-98 / TE-98 LQ TE-97 / TE-97 LQ Connection W&H Roto Quick Rotary instruments ISO (Ø mm) Maximum length approved by W&H (mm) Minimum chucking length until back stop Maximum operating part diameter (mm) 2 Maximum idle mode speed (± 30,000 min -1 ) (min -1 ) 330, ,000 Coolant volume ISO , ISO (ml/min) > 50 Water setting range (Recommended water pressure) (bar) (1.5) Chip air setting range (Recommended chip air pressure) (bar) (2) Exhaust pressure (bar) < 0.5 Recommended operating pressure (bar) Air consumption (Nl/min) min -1 (Revolutions per minute) 63

64 8. Technical data Turbine handpiece TE-95 BC / TE-98 BC TE-97 BC Connection according to standard EN ISO 9168:2009 Type 1: Borden 2-hole Rotary instruments ISO (Ø mm) Maximum length approved by W&H (mm) Minimum chucking length until back stop Maximum operating part diameter (mm) 2 Maximum idle mode speed (± 30,000 min -1 ) (min -1 ) 330, ,000 Coolant volume ISO , ISO (ml/min) > 50 Water setting range (Recommended water pressure) (bar) (1.5) Chip air setting range (Recommended chip air pressure) (bar) (2) Exhaust pressure (bar) < 0.5 Recommended operating pressure (bar) Air consumption (Nl/min) min -1 (Revolutions per minute) 64

65 8. Technical data Turbine handpiece TE-95 RM / TE-98 RM TE-97 RM Connection according to standard EN ISO 9168:2009 Type 3: Standard 4-hole Rotary instruments ISO (Ø mm) Maximum length approved by W&H (mm) Minimum chucking length until back stop Maximum operating part diameter (mm) 2 Maximum idle mode speed (± 30,000 min -1 ) (min -1 ) 330, ,000 Coolant volume ISO , ISO (ml/min) > 50 Water setting range (Recommended water pressure) (bar) (1.5) Chip air setting range (Recommended chip air pressure) (bar) (2) Exhaust pressure (bar) < 0.5 Recommended operating pressure (bar) Air consumption (Nl/min) min -1 (Revolutions per minute) 65

66 8. Technical data Roto Quick coupling RQ-53 RQ-54 Connection according to standard EN ISO 9168:2009 Type 1: Borden 2-hole Type 3: Standard 4-hole Recommended operating pressure (bar)

67 9. Recycling and disposal Recycling W&H considers that it has a special duty towards the environment. The turbine handpiece / Roto Quick coupling along with its packaging has been designed to be as environmentally friendly as possible. Disposal of the turbine handpiece / Roto Quick coupling > Follow your country-specific laws, directives, standards and guidelines for the disposal of used electrical devices. > Ensure that the parts are not contaminated on disposal. Disposal of the packaging material All packaging materials have been selected according to environmentally compatible and disposal aspects and can be recycled. Please send old packaging materials to the relevant collection and reprocessing system. This way, you will contribute to the recycling of raw materials and the avoidance of waste. 67

68 Explanation of warranty terms This W&H product has been manufactured with great care by highly qualified specialists. A wide variety of tests and controls guarantee faultless operation. Please note that claims under warranty can only be validated when all the directions in the Instructions for use have been followed. As manufacturer, W&H is liable for material or manufacturing defects within a warranty period of 12 months from the date of purchase. We accept no responsibility for damage caused by incorrect handling or by repairs carried out by third parties not authorized to do so by W&H! Claims under warranty accompanied by proof of purchase must be sent to the vendor or to an authorized W&H service partner. The provision of service under warranty extends neither the warranty period nor any other guarantee period. 12 months warranty

69 Authorized W&H service partners Find your nearest W&H service partner at Simply go to the menu option»service«for full details. Alternatively please contact: W&H (UK) Limited, Unit 6, Stroud Wood Business Centre, Park Street, St Albans, AL2 2NJ Hertfordshire t , f , technical.uk@wh.com W&H IMPEX INC., 6490 Hawthorne Drive, Windsor, Ontario, N8T 1J9, Canada t , f , service.ca@wh.com W&H IMPEX INC., Henn Road, Dearborn, MI 48126, USA t , f , service.us@wh.com W&H Austria GmbH, Ignaz-Glaser-Straße 53, 5111 Bürmoos, Austria t , f , office.at@wh.com A-DEC Australia, Office and showroom, Unit 8, 5-9 Ricketty Street, 2020 Mascot NSW t , f , a-dec@a-dec.com.au 69

70 Manufacturer W&H Dentalwerk Bürmoos GmbH Ignaz-Glaser-Straße 53, 5111 Bürmoos, Austria t , f office@wh.com wh.com Form-Nr AEN Rev. 001 / Subject to alterations

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060) Instructions for use BA Optima Air motors BA602 (BA640081) BA604 (BA640060) Contents 1. Introduction....3 5 2. Safety notes...6 9 3. Product description... 10 11 4. Operation... 12 13 Assembly/Removal,

More information

Instructions for use Handpiece Contra-angle handpieces with light Contra-angle handpieces without light

Instructions for use Handpiece Contra-angle handpieces with light Contra-angle handpieces without light Instructions for use Handpiece HE-43, HE-43 A/E Contra-angle handpieces with light WE-56 LED G, WE-66 LED G, WE-99 LED G Contra-angle handpieces without light WE-56, WE-56 A/E, WE-57 E, WE-66, WE-66 A/E,

More information

X99 Series. Dental Handpiece. Instruction For Use

X99 Series. Dental Handpiece. Instruction For Use X99 Series Dental Handpiece Instruction For Use 0413 Table of Contents Symbols... 2 Introduction... 3-4 Before Use... 5 Product description... 6 Technical Specifications... 7 Operation... 8-11 Hygienic

More information

Instructions for use. 301 plus

Instructions for use. 301 plus Instructions for use 301 plus Contents W&H symbols... 3 1. Introduction...4 5 2. Unpacking... 6 3. Package contents... 7 4. Safety precautions... 8 5. Description of the front side... 9 6. Description

More information

Instructions for use. 3x3 (MB-300) 3x2 (MB-200)

Instructions for use. 3x3 (MB-300) 3x2 (MB-200) Instructions for use 3x3 (MB-300) 3x2 (MB-200) Contents W&H Symbols...5 7 1. Introduction... 8 10 2. Electromagnetic compatibility (EMC)... 11 3. Unpacking...12 4. Scope of delivery...13 5. Safety notes...

More information

Instructions for use PA-123 / PA-115

Instructions for use PA-123 / PA-115 Instructions for use PA-123 / PA-115 Contents W&H symbols...4 6 1. Introduction...7 8 2. Electromagnetic compatibility (EMC)... 9 3. Unpacking...10 4. Equipment supplied... 11 5. Safety notes... 12 16

More information

Instructions for use SI-923 / SI-915

Instructions for use SI-923 / SI-915 Instructions for use SI-923 / SI-915 Contents W&H Symbols... 3 6 1. Introduction... 7 8 2. Electromagnetic compatibility (EMC)...9 3. Unpacking...10 4. Scope of delivery...11 5. Safety notes... 12 16 6.

More information

Instructions for use SA-310

Instructions for use SA-310 Instructions for use SA-310 Contents W&H Symbols... 3 6 1. Introduction... 7 8 2. Electromagnetic compatibility (EMC)...9 3. Unpacking...10 4. Scope of delivery...11 5. Safety notes... 12 16 6. Description

More information

Table of Contents. English

Table of Contents. English OM-E0799E 000 English Thank you for purchasing VIVA ace Motor Kit. Please read this Operation Manual and the VIVA ace Basic Set Operation Manual carefully before use for operating instructions and care

More information

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/ General Information Use The Air drill System is a pneumatic powered system used for many applications orthopedic and trauma surgery. To ensure proper operation of the air drill, use only original attachment

More information

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI ULTRASONIC SCALER PIEZO MINI CONTENTS XI - SYMBOLS 1. INTRODUCTION 1 Alternating current Type BF device 2. WARNINGS 1 3. PRESENTATION 1 3.1 Presentation 1 3.2 Technical description 2! Warning, please refer

More information

Contents. English. English

Contents. English. English OM-E0798E 000 Thank you for purchasing VIVA ace Basic Set. This product is a Portable Dental Treatment Unit used for on-site patient treatment. Please read this Operation Manual carefully before use so

More information

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference. OPERATION MANUAL LED Coupling OM-TR355E Please read this operation manual carefully and file for future reference. Caution When operating the product always consider the safety of the patient. The product

More information

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see  for demo video Keeping you insafehands to avoid needlestick injuries Astek Innovations Ltd Astek House I Atlantic Street I Altrincham Cheshire I WA14 5DH I United Kingdom Telephone +44 (0)161 942 3900 I Fax +44 (0)161

More information

I.F.U Re/Processing Reusable Medical Devices

I.F.U Re/Processing Reusable Medical Devices I.F.U Re/Processing Reusable Medical Devices Distributed by: MANUFACTURER: GA 26-09-001 -EN /20130719 Contents 1 Overview of preparation methods... 3 2 Safety and responsibility... 4 3 Explanation of symbols...

More information

ComPact Air Drive II USER S MANUAL

ComPact Air Drive II USER S MANUAL ComPact Air Drive II USER S MANUAL R Original Instruments and Implants of the Association for the Study of Internal Fixation AO ASIF TABLE OF CONTENTS Page ComPact Air Drive II Specifications... 2 Attachments...

More information

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/ HIGH-FLOW Arthroscopy Sheath with one or two rotating Stopcocks HIGH-FLOW Arthroscopy Sheath with one or two rotating Stopcocks 65-227-01-65-240-12 1 Safety and responsibility Before using the instrument

More information

Installation Instructions. Mira LED Light System

Installation Instructions. Mira LED Light System Installation Instructions Mira LED Light System w w w. a m i c o. c o m Contents Symbols Used in This Manual 4 Safety Instructions 5 Variants 7 Scope Of Delivery 8 Installing Mira LED Ceiling Mounted Installing

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

CONSTANT SUCTION UNIT

CONSTANT SUCTION UNIT CONSTANT SUCTION UNIT OPERATOR/MAINTENANCE M A N U A L Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive Gurnee, IL 60031-4099 1-800-662-5822/847-855-0800 Fax: 847-855-6218 www.aerosinstruments.com

More information

EL400 OPERATION MANUAL

EL400 OPERATION MANUAL All Titanium Body Micromotor System EL400 OPERATION MANUAL 40,000min -1 (rpm) OM-E0078E Rev.3 Please read this operation manual carefully before use and keep for future reference. Classification of equipment

More information

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215] PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA 19440-0907 USA [215] 723-4000 / FAX [215] 723-2199 USER INSTRUCTIONS FOR ASSEMBLY INSTALLATION AND CLEANING PORTER Scavenger

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

Instructions for Use. Air Power Line II. Power tools for endoprosthetics and traumatology.

Instructions for Use. Air Power Line II. Power tools for endoprosthetics and traumatology. Instructions for Use Air Power Line II. Power tools for endoprosthetics and traumatology. Contents Introduction General information 3 Startup of the Air Power Line system 5 Working with the Air Power

More information

RENZ FOR QUALITY PRODUCT CATALOGUE.

RENZ FOR QUALITY PRODUCT CATALOGUE. RENZ FOR QUALITY PRODUCT CATALOGUE 2018 www.reinigungspistolen.de Stainless Steel Spray Guns with stainless steel quick snap-closing connector autoclavable dismantled without tools Sterilization of the

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.75 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE WHAT S IN THE PACKAGE? This Operation Manual. (1) Vacuum Sealer. (1) E-(unit size) Heating Element, inside the

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

MemoirsStately3HoleBasin Mixer Installation and User Guide

MemoirsStately3HoleBasin Mixer Installation and User Guide P3907005 MemoirsStately3HoleBasin Mixer Installation and User Guide 454W 3S 454W 4S 454W-4V MODEL NUMBERS Important :- Please quote the above model number(s) when ordering spares. IMPORTANT! Installer:

More information

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM AIR CONDITIONING BASICS COMPRESSOR REPLACEMENT OVERVIEW AND IMPORTANT INSTRUCTIONS The air conditioning compressor

More information

HD Kompakt Service Manual

HD Kompakt Service Manual HD Kompakt Service Manual English 5.906-583.0 Rev. 00 (08/13) 1 1 Contents 1 Contents.................................................... 2 2 Preface.....................................................

More information

_i=ãçíçê _i=b=ãçíçê _i=fpl=ãçíçê _i=fpl=`lblp=ãçíçê _i=fãéä~åí=ãçíçê

_i=ãçíçê _i=b=ãçíçê _i=fpl=ãçíçê _i=fpl=`lblp=ãçíçê _i=fãéä~åí=ãçíçê kéï=~ë=çñw= lééê~íáåö=fåëíêìåíáçåë MNKOMNS _i=ãçíçê _i=b=ãçíçê _i=fpl=ãçíçê _i=fpl=`lblp=ãçíçê _i=fãéä~åí=ãçíçê båöäáëü Operating instructions / XY Motor / ISO adapter / Basic adapter (PEX) = Table of

More information

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use 1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically

More information

GALAXY FLOOR MACHINE

GALAXY FLOOR MACHINE OPERATION MANUAL GALAXY FLOOR MACHINE IMPORTANT SAFETY INSTRUCTIONS WARNING: Failure to observe these instructions can cause personal injury to machine operator or bystanders. WARNING: Shock or electrocution

More information

Instructions. Portable Absorb Phlegm. Apparatus

Instructions. Portable Absorb Phlegm. Apparatus Instructions On Portable Absorb Phlegm Apparatus Please carefully read the instructions before attempting to operate this apparatus. Product Features 1. General Portable absorb phlegm apparatus designed

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/ Arthroscopy irrigation cannula Arthroscopy irrigation cannulas 65-201-00-65-202-00 01 Stopcock left 02 Spring Cap 03 Cannula CLEANING / STERILIZATION Immediately after use the instruments have to be soaked

More information

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental IC9: 0600 LAUNDRY 1.0 STANDARD All staff must follow Routine Practices when handling soiled Off site processing (general linen) Off site processing (general linen) will not require special separation of

More information

Reusable Laryngoscope Blades and Handles

Reusable Laryngoscope Blades and Handles Manufacturer: Starkling Medizintechnik Method: Re-processing instructions Symbol: N.A. Device(s): 1 Green System Reusable Laryngoscope Blade with integrated Light Guide, Solid Stainless Steel Construction

More information

K 2.900M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them

K 2.900M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them K 2.900M Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. 5.961-933.0 01/07 2 Dear Customer, Please read and comply with these instructions

More information

Flipside Handshower and Showerhead Installation and User Guide

Flipside Handshower and Showerhead Installation and User Guide 17493W-CP 15996W-CP Flipside Handshower and Showerhead Installation and User Guide MODEL NUMBERS 17493W-CP, 15996W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT INSTALLER:

More information

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE WHAT S IN THE PACKAGE? This Operation Manual. (1) Vacuum Sealer. (1) E-(unit size) Heating Element, inside the manual sheet protector.

More information

model No: ir20.v2 FUSE

model No: ir20.v2 FUSE InstructioNS for: model No: ir20.v2 INFRARED PARAFfIN / KEROSENE / diesel HEATER 70000Btu 230V Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.35 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

Power Wash 2000W Car. User Guide. HPW2C-ZA hoover.za.com. Version 1.0

Power Wash 2000W Car. User Guide. HPW2C-ZA hoover.za.com. Version 1.0 Power Wash 2000W Car User Guide HPW2C-ZA hoover.za.com Version 1.0 2 CONTENTS MACHINE OVERVIEW 3 Contents Machine Overview General Safety Information Operation Maintenance FAQs Warranty Other Information

More information

Singulier Spout Tube Basin Mixer Installation and User Guide

Singulier Spout Tube Basin Mixer Installation and User Guide Singulier Spout Tube Basin Mixer Installation and User Guide MODEL NUMBERS 10862W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the property

More information

ORIGINAL INSTRUCTIONS

ORIGINAL INSTRUCTIONS WARNING: Read the instructions before using the machine. POWER WASHER MODEL NO: JETSTAR 1950 PART NO: 7336010 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0617 - ISS 3 INTRODUCTION Thank

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM: Get ready to deep clean! Pressure Washer Montgomery Ward Customer Service 3650 Milwaukee Street, Madison, WI 53714 8:00 am to Midnight, Monday through Friday Wards.com Instruction Manual ITEM: 751821 Wards.com

More information

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20 Operation Manual Mobile Dustfree Pressure Air Blasting System HSP-20 Clemco International GmbH Carl-Zeiss-Straße 21 Tel.: +49 (0) 8062 90080 83052 Bruckmühl Mail: info@clemco.de Germany Web: www.clemco-international.com

More information

Oblo Basin and Bidet Monobloc Installation and User Guide

Oblo Basin and Bidet Monobloc Installation and User Guide Oblo Basin and Bidet Monobloc Installation and User Guide MODEL NUMBERS 10085W-CP, 10088W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP InstructioNS for: INFRARED PARAFfIN / KEROSENE / diesel HEATER model No: ir20.v2 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

CREMALDI Cream machines Operating instructions

CREMALDI Cream machines Operating instructions Vaihinger GmbH Horstweg 29 65520 Bad Camberg-Erbach Telefon 0 64 34 / 94 05 0 Telefax 0 64 34 / 94 05 99 http://www.sanomat.com info@vaihinger.com CREMALDI Cream machines Operating instructions CONTENTS

More information

NSS STANDARD-SPEED FLOOR MACHINES

NSS STANDARD-SPEED FLOOR MACHINES OPERATION MANUAL NSS STANDARD-SPEED FLOOR MACHINES IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using or servicing machine. WARNING: Fire or explosion hazard. NEVER use with flammable or

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum

More information

INSTRUCTION MANUAL W-400

INSTRUCTION MANUAL W-400 USE and MAINTENANCE INSTRUCTION MANUAL Bellaria WBX WB GRAVITY SPRAY GUN Series LPH-400 WB en it fr es pt de se TECHNICAL DATA Classic Plus Series LPH-400 (LVLP) Classic Plus Nozzle_Needle set Combination

More information

CONTENTS. Fuji Limited 2 Year Warranty

CONTENTS. Fuji Limited 2 Year Warranty Fuji Limited 2 Year Warranty Fuji Industrial Spray Equipment Ltd. ( Fuji ) provides a 24 month limited warranty on the product to the original purchaser effective from the date of purchase against defects

More information

Dental Unit User's Guide

Dental Unit User's Guide Dental Unit User's Guide MDD 93/42/EEC May 1999 8200590 Quint-7000 User's Guide We reserve the right to make changes. Manufactured by: FINNDENT OY Teollisuustie 5 FIN-07230 MONNINKYLÄ Tel. +358 19 5221500

More information

hp Dust Collector With Vacuum Attachment

hp Dust Collector With Vacuum Attachment Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Betriebsanleitung Operating Instructions

Betriebsanleitung Operating Instructions Betriebsanleitung Operating Instructions Oil mist filter idealvac.com (505)872-0037 idealvac.com ONF 16 PK 0213 BE/G (0811) ONF 25/25L/25XL Table of contents Table of contents 1 About this manual......................................

More information

Tempest TP420/180 Electric Pressure Washer

Tempest TP420/180 Electric Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

- website: Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK

- website:   Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK V-026PT User Guide.qxd 7/9/06 15:13 Page 12 EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: Vax Limited, hereby on our own responsibility, declare that the product V-026PT is manufactured in compliance

More information

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications TABLE OF CONTENTS MANUAL PRE-CLEANING High Speed Handpieces 2

More information

KB Operating Instructions. Before first use of the unit Please read these /07

KB Operating Instructions. Before first use of the unit Please read these /07 KB 6060 Operating Instructions Before first use of the unit Please read these Operating Instructions and act in accordance with them 5.962-095.0 01/07 2 Dear Customer, Please read and comply with these

More information

infrared paraffin / kerosene / diesel heater

infrared paraffin / kerosene / diesel heater instructions for infrared paraffin / kerosene / diesel heater model no: IR20.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

More information

Single Lever Pull Out Kitchen Faucet

Single Lever Pull Out Kitchen Faucet INSTALLATION MANUAL Single Lever Pull Out Kitchen Faucet KPF-02 www.kraususa.com I toll free:.00..003 I 203-20 Kraus USA Inc. Congratulations on your new Kraus purchase! We would like to take this opportunity

More information

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers OM010 Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers The operating and maintenance instructions contained within this package are for ThermaFlex gasketed

More information

PJ130S High Pressure Cleaner

PJ130S High Pressure Cleaner PJ130S High Pressure Cleaner Operator Manual Original instructions WARNING: Do not use the machine without reading the instruction sheet. Item Description OVERVIEW 1. High pressure washer 2. On/off switch

More information

User Manual J841Q. Magnetostrictive Scaler / Polisher Combo Unit. Jorgensen Laboratories Tel: Fax:

User Manual J841Q. Magnetostrictive Scaler / Polisher Combo Unit. Jorgensen Laboratories Tel: Fax: User Manual J841Q Magnetostrictive Scaler / Polisher Combo Unit Jorgensen Laboratories Tel: 800-525-5614 Fax: 970-663-5042 Email: jortech@jorvet.com 1 Warnings Important Notes! The equipment is only to

More information

Cleaning & Sterilization

Cleaning & Sterilization Handpieces & Attachments Instruments Cleaning & Sterilization System 7 System 6 System 5 CD4 CD3 SABO 2 SABO RemB CORE TPS Processing Instructions User/Patient Safety all contribute to the efficacy of

More information

Operator s Manual. IP-100 Immersion Probe Cooler

Operator s Manual. IP-100 Immersion Probe Cooler Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11 Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your

More information

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using. ENGLISH (Original instructions) INSTRUCTION MANUAL Demolition Hammer HM080TA 00079 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model HM080TA Blows per

More information

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. WARNING: Magnetic field hazard. This pump

More information

Operating Manual for Profident / Profident PLUS

Operating Manual for Profident / Profident PLUS Operating Manual for Profident / Profident PLUS Content: 1. Accessories... 1 2. First Steps... 2 2.1 Air Pressure... 2 2.2 Positioning of the Handpieces... 2 2.3 Pressurised Water Bottle... 3 2.3.1 Refill

More information

User Manual WMF Cup&Cool WMF Cup

User Manual WMF Cup&Cool WMF Cup coffee wakes up the world User Manual WMF Cup&Cool WMF Cup Add-on Equipment English bistro! 2000S presto! 1400 prestolino! 1300 Model Series 9018 / 9019 Order Nr. 33 0916 1000 Edition 04.2010 General Information

More information

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...

More information

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

Bedienungsanleitung. Ideas for dental technology. Made in Germany C Bedienungsanleitung 216604 C 01022013 Made in Germany Ideas for dental technology GLISH Instruction manual 1. Introduction...1 1.1 Employed Symbols...1 2. Safety...2 2.1 Intended use...2 2.2 Improper use...2

More information

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions. High-Pressure Washer BY02-VBP-WTH BY02-VBP-WTR CAUTION : Do not use this device before reading the instructions. 1 1. Safety Instructions The appliance has been designed solely for private use outdoors

More information

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0 Model: MPN: B0940 INSTALLATION INSTRUCTIONS Version: 1.0 READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT INSTRUCTIONS THAT, IF IGNORED COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING

More information

Bar Fridge USER MANUAL MB46W

Bar Fridge USER MANUAL MB46W Bar Fridge USER MANUAL MB46W CONTENTS Safety information... 2-3 Identifying parts of the fridge... 4 Transporting... 5 Installation... 5 Reversing the door... 6 Operating instructions... 7 Cleaning &

More information

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............

More information

Pop-up Clicker Drain Installation and User Guide

Pop-up Clicker Drain Installation and User Guide Pop-up Clicker Drain Installation and User Guide 7124W-A MODEL NUMBERS Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the property of the customer

More information

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se USE and MAINTANCE INSTRUCTION MANUAL WS-400 EVO LS-400 Entech GRAVITY SPRAY GUN Series en it fr es pt de se TECHNICAL DATA WS-400 WS-400 EVO WS-400 Clear WS-400 Base WS-400-1301 EVO 1.3 170 365 260 WS-400-1401

More information

Operating instructions

Operating instructions Operating instructions for automatic detergent dispensing unit AWD 10 To avoid the risk of accidents en - AU, NZ or damage to the appliance, it is essential to read these operating instructions before

More information

For cleaning machines, parts & supplies click/visit Electrolux Home Care Products Ltd.

For cleaning machines, parts & supplies click/visit Electrolux Home Care Products Ltd. Sanitaire 1.5 GALLON Carpet Spotter SC6075A Part No. SC6075A Rev 2 (9/13) Owner s Guide IMPORTANT Do not return this product to the store. Call 1-800-800-8975* Monday - Friday 8:00 AM to 7:30 PM and Saturday

More information

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk

More information

Instructions for use Vacuum regulation valve with water trap

Instructions for use Vacuum regulation valve with water trap Instructions for use Vacuum regulation valve with water trap Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for Cleaning and Care 3.1 Disassembling

More information

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ: User Guide Vax Careline: AU: 1300 361 505 NZ: 0800 800 900 Carpet Washer Get Cleaning... What s your Vax s model number? W8 W8 W0 W0 W0 W W W W W What s your serial number? (Located on the base of the

More information

OMNIVAC secretion aspiration system Description of device and instructions for use

OMNIVAC secretion aspiration system Description of device and instructions for use OMNIVAC OMNIVAC secretion aspiration system Description of device and instructions for use Contents 1.Description of device..........................2 1.1 Intended use........................... 2 1.2

More information

Combivac Operating Instructions Combivac

Combivac Operating Instructions Combivac Combivac 17-36 Operating Instructions Combivac General Table of contents General...2 Table of contents...2 Information about the operating instructions...3 Liability...3 Notices in the operating instructions...3

More information

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa) Operation Pro Pack Portable Spray Pack - For use with Graco hand-held sprayers (except Fine-Finish sprayers) - - For portable spray applications of water-based and oil-based (mineral spirit-type) architectural

More information

AlcoBlow. User Handbook

AlcoBlow. User Handbook AlcoBlow User Handbook RM42053 Revision 2.3 June 2013 Unit and Controls 1 ON/OFF Switch 2 STATUS Light 3 Sample Cone 4 PASSIVE Switch 5 DISPLAY Light 6 Battery Cap 2 Contents 1 SAFETY INFORMATION 5 2 USEFUL

More information

Integra Ultrasonic Tooth Scaler

Integra Ultrasonic Tooth Scaler Caution: Federal Law restricts this device to sale by or on the order of a properly licensed practitioner. Integra Ultrasonic Tooth Scaler Model D680 Device Description: The Integra is an autotune ultrasonic

More information

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98) 32506 Upholstery and Drapery Cleaner Model No.: 32506 3 gal Extractor Operator and Parts Manual KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U.S.A. FAX: 1-559-673-5725 CUSTOMER SERVICE: 1-800-241-4865 MNL32506

More information

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK   - website: V-027P Rapide Pet User Guide 10/7/07 10:05 Page 14 EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: VAX Limited, hereby on our own responsibility declare that the products V-027/V-027PT/V-027P/CCW-701

More information

Dosing system. Commissioning and maintenance manual eco-pen300

Dosing system. Commissioning and maintenance manual eco-pen300 Dosing system Commissioning and maintenance manual eco-pen300 Item number 20506 Print 21.2.12 Contents 1 This Manual 5 2 The dispenser 5 3 Safety 5 4 Starting up for the first time 6 4.1 Inserting the

More information

INSTRUCTION MANUAL FOR MINI SUCTION UNIT

INSTRUCTION MANUAL FOR MINI SUCTION UNIT INSTRUCTION MANUAL FOR MINI SUCTION UNIT MINI SUCTION UNIT WITH DISPOSABLE SALIVER TANK. MINI SUCTION UNIT WITH STANDARD SALIVER TANK MINI SUCTION VERSION DATE 15.02.2011 VERSION NO : 1-2011 1 1. General

More information

Blueberry Kitchen Sink Tap

Blueberry Kitchen Sink Tap Blueberry Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s

More information