Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

Size: px
Start display at page:

Download "Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual"

Transcription

1 Ellis Dryer Control Configuration and Operation Manual Revised 1/19/2004

2 Table of Contents 1 Introduction Hardware Specifications Software Features Warranty Terms Exclusions Replacement of Parts Under Warranty Display/Keypad Layout Run Mode/Idle Active Keys Mode Select Displays Select Formula Select Step Run a Formula Run Mode/Running Active Keys Running Formula Maintain Outlet Temperature Setting Maintain Inlet Temperature Setting Inlet/Outlet Temperature Difference Humidity Recirculation Run Mode/Stopped Active Keys Program Mode Entering Program Mode Active Keys Displays Selecting a Formula Editing the Formula Name Active Keys Sample Formula Name Program/Edit Formula Steps Selecting Step to Edit Clearing a Step Saving a Step Programming Outputs Programming Temperatures Programming Time Programming Humidity End Step Programming Edit Sample Formula Programming Procedure Exit Program Mode Manual Mode Entering Manual Mode Active Keys Displays Reviewing Formula Counters Resetting Daily Counters Exiting Manual Mode Options Mode Entering Options Mode Section 1 Introduction Page 2

3 7.2 Active Keys Option Settings Motor On Motor Off Signal On Signal Off Display Brightness Temperature Timeout Allow Step Advance Password Chirp Time Low Temperature Open Door Time Raise Machine Time Humidity at Setpoint Time Inlet Temperature Limit Outlet Temperature Limit Wait for Temp. to Start Step Timer Rotate Basket After Low Temperature Keep Blowers On In End Step Rotate Basket In End Step Automatically Reset Display Modes Set Up Service Alerts Factory Options Exiting Options Mode Factory Options Entering Factory Options Active Keys I/O Assignments High Fire Low Fire Recirculation Signal Basket Forward Basket Reverse (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) Auxiliary Auxiliary Auxiliary Auxiliary Gas Blower Exhaust Blower Lint Blowdown De-Linter Flame Control Enable Exhaust Pressure Gas Pressure Excessive Backpressure Lint Thermal Switch Modulating Valve Enable Modulating Valve Open Section 1 Introduction Page 3

4 Dryer Control Operation Manual Modulating Valve Closed Start Stop Formula Up Formula Down Hold Communication Basket Motor Overload Blower Motor Overload Basket Rotation Supervisor Key Front Tilt Safety Jog Run Position Front Load Position Front Unload Position Front Door Open Front Door Closed Front Raise Door Front Lower Door Front Raise Rear Lower Rear Raise Front Lower Front Run Position Rear Load Position Rear Unload Position Rear Door Open Rear Door Closed Rear Raise Door Rear Lower Door Rear Jog Forward Front Jog Forward Rear Jog Reverse Front Jog Reverse Rear Cycle End Soil Brush Front Control Rear Control Rear Tilt Safety Movement Alarm Blower Door Fire Alarm/High Limit Main Power On/MCR Low Gas Pressure Burner Motor Overload Input Power On Burner Pressure Sprinkler System Cutoff Cooldown Light Vari-Air Pilot Safeties Dryer Ready Flame Control Error Multi Relay Assignments Machine Configuration Page 4 Section 1 Introduction

5 8.5.1 Display Average Inlet Proportional Band Inlet Integral Constant Inlet Derivative Constant Outlet Proportional Band Outlet Integral Constant Outlet Derivative Constant Flame Control Timeout Inlet Valve Offset Outlet Valve Offset Basket Rotation Time Motor Starter Time Delay Fire Alarm Startup Delay Lint Trap Blowdown Time Lint Trap Blowdown Frequency Lint Trap Blowdown On Start Lint Trap Blowdown On Stop Lint Trap Blowdown At Formula End Lint Trap Blowdown Delay At End Inlet Temperature Offset Outlet Temperature Offset Minimum High Fire Valve Time Temperature Debounce Time Hysteresis A/D Converter Resolution Jog Delay Time Use Initial Purge Inlet-Outlet RS-485 Network Address Inlet Temperature Input/Type/Divider Outlet Temperature Input/Type/Divider Ambient Humidity Input/Type/Divider Outlet Humidity Input/Type/Divider Ambient Temperature Input/Type/Divider Panel Temperature Input/Type/Divider Valve Position Input/Type/Divider Metric Measurements Network Configuration Calibrate Gas Valve Purge Unused Operation Names Clear Formulas Input Indicator Assignments Clearing Entire Memory Exiting Factory Options Troubleshooting Inlet temp too high Outlet temp too high Front door switch failure Rear door switch failure Temperature timeout Flame control timeout Flame control pilot lost Flame control needs reset Excessive backpressure Basket not rotating Inlet temp sensor failure Section 1 Introduction Page 5

6 Dryer Control Operation Manual 9.12 Outlet temp sensor failure Sprinkler system disabled Blower motor starter failure Burner pressure too low Exhaust pressure too low Front door open switch failure Rear door open switch failure Front door closed switch failure Rear door closed switch failure Gas pressure too low Gas pressure too high Blower motor overload tripped Dryer not in level position Basket motor overload tripped Machine power lost Main fan door opened Exhaust temp too high Lint temperature too high DC input power lost Character Set Preprogrammed Step Names Settings Charts I/O Assignment Chart Options Machine Configuration Input Indicator Assignments Page 6 Section 1 Introduction

7 1 Introduction 1.1 Hardware Specifications Microcontroller: Z-180 RAM: 128k ROM: 256k Serial Port: Two ports, RS-485/RS-232 Character Display: 4x20 vacuum fluorescent Status LEDs: 25 Keypad: Sealed silver/carbon, 38 keys 1.2 Software Features 96 Dry formulas 7 Operations per formula Formulas may be configured to: dry at an outlet temperature for a programmed time dry at an inlet temperature for a programmed time dry until the inlet and outlet temperatures reach a programmed differential dry until an outlet humidity is reached dry until an outlet humidity is reached, then run for a programmed time Section 1 Introduction Page 7

8 Dryer Control Operation Manual 1.3 Warranty Terms All products manufactured by (CCS), are warranted against defects in material and workmanship for two years from the date of purchase. Warranty is extended to the original purchaser only. If a defect occurs, the product will be repaired, provided that inspection proves the claim, and that the purchaser give CCS written notice, or returns such defect within 30 days. Defective product shall be returned to the factory, freight prepaid, in original shipping package. extends this warranty in lieu of any other warranties expressed or implied, and CCS neither assumes, nor authorizes any other person to assume for it, any other liability in connection with its equipment. Remedies provided in this warranty shall constitute the exclusive remedies available to the original purchaser, and all other warranties and damages, statutory or otherwise, are hereby expressly waived by the original purchaser Exclusions 1. This warranty is void if the equipment is not properly installed, operated, and serviced as specified by the factory or if the equipment is not operated under normal conditions and with competent help. 2. Parts subject to normal wear or damaged by corrosion or exposure to weather, are not covered under this warranty. 3. This warranty does not cover labor to replace defective parts. 4. Expenses for removal and replacement of defective parts are not assumed by CCS. 5. Any modification made to CCS equipment after shipment from the factory or replacement of parts with types or makes other than originally furnished with the equipment, voids this warranty, unless such change or replacement has been approved in writing by CCS. 6. This warranty does not include any liability for consequential or incidental damage attributable to failure of any part of the equipment. 7. Although sold by CCS, equipment manufactured by others which is not an integral part of a CCS control, is excluded from this warranty, but may be covered by a warranty of the other manufactures. Page 8 Section 1 Introduction

9 1.3.3 Replacement of Parts Under Warranty Ordering Replacement Parts When ordering replacement parts, furnish the following information: 1. Model number and serial number. 2. Part number, description and quantity. 3. Shipping instructions Returning Parts Under Warranty All parts furnished under warranty will be invoiced by CCS. If we do not want the part to be returned for inspection, the invoice will show that the replacement part was furnished at no charge. If however, the part is to be returned for inspection and possible credit, the invoice will show the cost of the part, and credit will be issued upon receipt of the defective part provided: 1. The replaced parts must be returned to the factory, freight prepaid, within 30 days from the date of invoice. 2. Each part to be returned for credit and inspection must be tagged, showing name of customer, invoice number of replacement part, and a brief explanation of difficulty. (Be more explicit than stating N.G. or Defective.) Pack parts carefully, to avoid damage in shipment. 3. The inspection must prove that the part was defective and had to be replaced. 4. Replacement parts will be shipped freight prepaid and the amount will be added to the invoice. If the returned part proves to be defective, the credit issued for the part will include minimum shipping charges incurred. No allowance will be made for air freight or express shipments. 5. Replacement parts which are returned unused are subject to a 25% restocking charge. Special made parts that are not normally stocked by CCS are not returnable for credit. Section 1 Introduction Page 9

10 Dryer Control Operation Manual 1.4 Display/Keypad Layout Page 10 Section 1 Introduction

11 2 Run Mode/Idle When the control first powers up, it is in Run Mode/Idle. In Run Mode/Idle, you can select and start a formula as well as load or unload the dryer. 2.1 Active Keys - Used to enter formula number. Selects next programmed formula. Selects previous programmed formula. Switches display between actual inlet and outlet temperatures, programmed inlet and outlet temperatures, the programmed and actual temperature difference, and the set and actual modulating gas valve positions. Selects operation mode (will take user from Run Mode to Program Mode). Switches display between programmed step time, formula remaining time, formula elapsed time, and step time remaining. Switches display between programmed humidity, outlet humidity, and ambient humidity. Starts running the currently selected formula. Allows operator to select individual steps in the current fomula. Exits step selection and returns to formula selection. 2.2 Mode Select When the processor is first powered up, it will be in the Run Mode. To change to any of the other modes (Program Mode, Manual Mode, Options Mode), press the key. You may be required to enter a password (see Password, section 7.3.8, page 32) to leave the Run Mode. 2.3 Displays When the control first powers up, the control shows formula information on the top two lines of the display, and machine status information on the bottom two lines of the display. 0 1 F o r m u l a % F 8 7 F 1 1 : 0 0 W a i t i n g f o r S t a r t B u t t o n Section 2 Run Mode/Idle Page 11

12 Dryer Control Operation Manual Formula Information - shows the formula name and number, current humidity, step number, inlet temperature, outlet temperature, and step time remaining. Formula # Formula Name or Step Name Humidity 0 1 F o r m u l a % F 8 7 F 1 1 : 0 0 Step# Inlet Temp Outlet Temp Time Machine Status shows what the machine is currently doing, as well as any error conditions that might occur. W a i t i n g f o r s t a r t b u t t o n 2.4 Select Formula Formulas can be selected by one of two methods: 1. Press the and keys to scroll through the available formulas. The formula number and name will appear on the top line with the step number, temperature, level and time appearing on the second line. 2. Press the numeric keypad ( - ) to enter the desired formula number (01=formula 1; 16=formula 16). The formula number and name will appear on the top line and the step number will appear on the second line. If a mistake is made, reenter the desired formula number. NOTE: Formulas can only be selected after the current formula has run to the end step and the signal or stop buttons have been pressed. This feature can be bypassed if desired (see Allow Step Advance, section 7.3.7, page 31). 2.5 Select Step To scroll through the available steps in the selected formula, press then use or to scroll to the desired step. The step name will appear on the top line and the step number will appear on the second line. Press to return to formula selection. NOTE: Selecting Steps is protected by an Option Setting, but can be unprotected if desired (see Allow Step Advance, section 7.3.7, page 31). 2.6 Run a Formula Select desired formula, then press the Run Mode/Running. key. The control will start the washer, and will enter Page 12 Section 2 Run Mode/Idle

13 3 Run Mode/Running 3.1 Active Keys Used to stop the dryer. The control will enter the Run Mode/Stopped mode. Switches display between actual inlet and outlet temperatures, programmed inlet and outlet temperatures, the programmed and actual temperature difference, and the set and actual modulating gas valve positions. Switches display between programmed step time, formula remaining time, formula elapsed time, and step time remaining. Switches display between programmed humidity, outlet humidity, and ambient humidity. 3.2 Running Formula The control will begin running the formula with the currently selected step. The step timer will be started when the step s other criteria are met Maintain Outlet Temperature Setting The control will open the high fire or proportional gas valve to raise the outlet temperature when below the setpoint. The control will close the high fire or proportional gas valve to lower the outlet temperature when above the setpoint. The control will start the step timer when the programmed outlet temperature is first achieved after the control is started Maintain Inlet Temperature Setting The control will open the high fire or proportional gas valve to raise the inlet temperature when below the setpoint. The control will close the high fire or proportional gas valve to lower the inlet temperature when above the setpoint. The control will switch to outlet temperature control when the programmed outlet temperature is reached Inlet/Outlet Temperature Difference The control will open the high fire or proportional gas valve to raise the outlet temperature when below the setpoint. The control will close the high fire or proportional gas valve to lower the outlet temperature when above the setpoint. The control will start the step timer when the programmed difference between the inlet and outlet temperatures is reached Humidity The control will open the high fire or proportional gas valve to raise the outlet temperature when below the setpoint. The control will close the high fire or proportional gas valve to lower the outlet temperature when above the setpoint. The control will start the step timer when the outlet humidity has reached the setpoint and has remained there for the Humidity at Setpoint Time (section , page 32). Section 3 Run Mode/Running Page 13

14 Dryer Control Operation Manual Recirculation The control will open the high fire or proportional gas valve to raise the outlet temperature when below the setpoint. The control will close the high fire or proportional gas valve to lower the outlet temperature when above the setpoint. The control will close the recirculation damper for the amount of time programmed in the step, beginning when the dryer is started (see Programming Outputs, section 5.6.4, page 21). Page 14 Section 3 Run Mode/Running

15 4 Run Mode/Stopped If the dryer stops while running a formula either because the operator presses the key, or because an error condition has occurred, the control will enter Run Mode/Stopped. When stopped, the dryer door may be opened (assuming that the dryer temperature is below the low temperature setting (section , page 32) and the dryer may be unloaded. 4.1 Active Keys Switches display between actual inlet and outlet temperatures, programmed inlet and outlet temperatures, the programmed and actual temperature difference, and the set and actual modulating gas valve positions. Selects operation mode (will take user from Run Mode to Program Mode). Switches display between programmed step time, formula remaining time, formula elapsed time, and step time remaining. Switches display between programmed humidity, outlet humidity, and ambient humidity. Starts running the currently selected formula. Section 4 Run Mode/Stopped Page 15

16 Dryer Control Operation Manual 5 Program Mode The Program Mode is used to configure the control s dry formulas. The user may configure up to 96 dry formulas consisting of up to 7 steps each. This section explains how to select and name formulas, program dry steps, and enter temperature and humidity settings. Steps may be inserted, deleted or renamed. 5.1 Entering Program Mode If the password feature has not been enabled, press the key and proceed to step 4 below. Otherwise, start with step 1. Note: the factory default password is To change the control password, see Password, section on page 32. This example assumes that the control has been set up with the factory default password. If your password is different, use it instead. 1. Press the key. (example for the default password) The display will now read: P a s s w o r d 2. Press. The display will now read: P a s s w o r d * * * * 3. Press the key. The control will now be in the Program Mode, and the PRO light will be illuminated. Page 16 Section 5 Program Mode

17 5.2 Active Keys Selects the next formula or step (will discard any changes made to the current step if the step has not been saved). Selects the previous formula or step (will discard any changes made to the current step if the step has not been saved). Programs inlet temperature, outlet temperature, and temperature difference setpoints for the current step. Programs step time for the current step. Programs humidity for the current step. Makes the current step an End Step. Start editing the steps of current formula. Exits step programming mode. Selects operation mode (will take user from Program Mode to Manual Mode). 5.3 Displays When the control first enters the Program Mode, the display will show the formula name and number, step number, programmed temperatures and programmed time. The status LEDs will show the outputs that have been programmed for that step. Formula # Formula Name or Step Name Humidity 0 1 F o r m u l a h i o 1 5 : 0 0 Step# Inlet Temp Outlet Temp Time 5.4 Selecting a Formula Select the Formula to be edited using the key to go to the next-higher numbered formula and the key to go to the next-lower numbered formula. Section 5 Program Mode Page 17

18 Dryer Control Operation Manual 5.5 Editing the Formula Name The formula name is displayed to the right of the formula number. If you want to change the name of a formula, you must first make sure that you are displaying the formula name, not the step name. When shipped from the factory, the control will have generic formula names programmed into it Formula 1, Formula 2, etc. If the control is not showing the formula name, press the key to exit step editing mode. Press the key, and the display will read: F o r m u l a e d i t 1 - S t e p s 2 - N a m e Press to edit name. A flashing cursor will appear on the first letter of the formula name. 0 1 F o r m u l a Active Keys Clears the formula name. Pressing the clear key twice restores the original name. Saves the formula name. - Use these keys to enter letters and numbers. When editing the formula name, the first time you press the button, you will get the number. The second time you press it, you get the first letter. The third time you press it, you get the second letter, and so on. Moves the cursor one space to the right. Moves the cursor one space to the left. Switches between capital and lowercase letters Sample Formula Name To change the name of formula 1 from Formula 1 to Pants, Press the display will read: key, and the F o r m u l a e d i t 1 - S t e p s 2 - N a m e Press to edit name. A flashing cursor will appear on the first letter of the formula name. Page 18 Section 5 Program Mode

19 0 1 F o r m u l a 1 Press to clear the formula name. The display will read: 0 1 Press the key once. The display will read: Press the key a second time. The display will read: 0 1 P Now, press the key to move the cursor one spot to the right. 0 1 P Press the key to switch to lowercase letters, then press the key. The display will read: 0 1 P 1 Press the key again. The display will read: 0 1 P a Now, press the key to move the cursor one spot to the right. Section 5 Program Mode Page 19

20 Dryer Control Operation Manual 0 1 P a Press the key. The display will read: 0 1 P a 5 Press the key again. The display will read: 0 1 P a m Press the key a third time. The display will read: 0 1 P a n Now, press the key to move the cursor one spot to the right. 0 1 P a n Press the key three times. The display will read: 0 1 P a n t Now, press the key to move the cursor one spot to the right. 0 1 P a n t Press the key twice more. The display will read: 0 1 P a n t s Page 20 Section 5 Program Mode

21 Now press to save the name. The display will read 0 1 P a n t s N a m e s a v e d for a few seconds, then return to the standard formula name display. 5.6 Program/Edit Formula Steps Once you have selected the formula you wish to edit, press the The display will read: key to access the step editor. F o r m u l a e d i t 1 - S t e p s 2 - N a m e Press programmed on that step. to edit steps. The display will now show the step name and the parameters 0 1 D r y O n e W a y 1 3 h i o 1 5 : Selecting Step to Edit Use the and keys to select the step to be edited Clearing a Step Use the key to clear all outputs, temperatures and times programmed on the current step Saving a Step The saving a step: key saves the current step. The control will display the following message when 0 1 D r y O n e W a y 1 3 h 0 1 S t e p s a v e d Programming Outputs Each step in a formula has different outputs programmed on it. An output is a machine function, such as the burner or basket rotation; when we say it is programmed, we mean that the control will automatically operate that machine function when running the formula. Each of the programmable outputs has an indicator light while will be illuminated if that output is programmed on the current step. On the dryer control, the following outputs are programmable: Section 5 Program Mode Page 21

22 Dryer Control Operation Manual programs the burner, or heat, on the current step. programs recirculation on the current step. programs forward basket rotation on the current step. programs reverse basket rotation on the current step Programming Temperatures The key is used to edit temperatures. Pressing the key cycles you between the following items: inlet temperature, outlet temperature, temperature difference and maximum valve position Programming Time The key is used to edit the programmed step time Programming Humidity The key is used to edit the programmed humidity on the current step End Step The key programs an End Step, which indicates to the control that the dry formula is done Programming Edit The [EDIT] key accesses the advance editing options. The control will display: 1 - I n s e r t, 2 - D e l e t e 3 - S t e p N a m e 4 - J u m p Insert The Insert function inserts a blank step before the current step. In other words, if you are working with step 2, and select insert, step 2 will become step 3, step 3 will become step 4 and so on, and a new blank step will be added as step Delete The delete function removes the current step from the formula and moves the remaining steps down. For example, if you are working with step 2 and select the delete function, step 3 will become step 2, step 4 will become step 3, and so on. A blank step will be added to the end of the formula Step Name The process of entering a step name is the same as the process of entering a formula name. See the example in Section 5.5.2, page Jump Allows you to quickly jump to another step in the formula. Page 22 Section 5 Program Mode

23 5.7 Sample Formula Programming Procedure Use the and keys to select the formula you wish to edit. Press the Press the key, and the display will read: F o r m u l a e d i t 1 - S t e p s 2 - N a m e Press to edit name. A flashing cursor will appear on the first letter of the formula name. 0 1 F o r m u l a 1 Follow the formula name programming procedures in Section 5.5.2, on page 18. Once you finished editing the formula name, press the key to access the step editor. The display will read: F o r m u l a e d i t 1 - S t e p s 2 - N a m e Press to edit steps. The display will now show step * * E n d * * 0 h 0 1 0i 0o 0: 0 0 Use the key to clear step one. The display will now read: 0 1 C o o l d o w n 0 h 0 1 0i 0o 0: 0 0 Typically, the first step of the formula is a heat step. Press the key to enable the burner, and the key to select forward rotation. The display will now read: Section 5 Program Mode Page 23

24 Dryer Control Operation Manual 0 1 D r y O n e W a y 0 h 0 1 0i 0o 0: 0 0 0d 0a Next, we will want to program our inlet and outlet temperatures, so press the cursor will start flashing on the inlet temperature: key. The 0 1 D r y O n e W a y 0 h 0 1 0i 0o 0: 0 0 0d 0a Use the number keys to type in your desired inlet temperature. In this case, press to enter 500 degrees. Then press again. 0 1 D r y O n e W a y 0 h i 0 o 0 : 0 0 0d 0a The cursor will now be blinking on the outlet temperature. Again, use the number keys to enter your desired outlet temperature, in this case, 180. Then press again. 0 1 D r y O n e W a y 0 h i o 0 : 0 0 0d 0a The cursor will now be blinking on the temperature difference. Leave this set to zero, and press again. 0 1 D r y O n e W a y 0 h i o 0 : 0 0 0d 0a The cursor will now be blinking on the maximum gas valve setting. Leave this set to zero, and press again. The cursor will stop blinking. Page 24 Section 5 Program Mode

25 Now, press the key. The cursor will start blinking on the step time. 0 1 D r y O n e W a y 0 h i o 0 : 0 0 0d 0a Use the number keys to enter your desired step time, in minutes and seconds. To program four minutes and thirty seconds, press, then press. Next, to program humidity, press the setting. key. The cursor will start blinking on the humidity 0 1 D r y O n e W a y 0 h i o 4 : 3 0 0d 0a Use the number keys to enter the desired humidity, and press the key again. Now, to save the step, press. The control will tell you that it is saving the step: 0 1 D r y O n e W a y 5 h 0 1 S t e p s a v e d The control will automatically advance to step two. The display will read: 0 1 C o o l d o w n 0 h 0 2 0i 0o 0: 0 0 Step two is typically a cooldown step. We re going to select forward rotation, by pressing the key, then press the.key twice to enter our desired cooldown temperature of 130 deg. 0 1 C o o l d o w n 0 h i o 0 : 0 0 Section 5 Program Mode Page 25

26 Dryer Control Operation Manual Once the cooldown outlet temperature is entered, press again. Now, to save the step, press. The control will tell you that it is saving the step: 0 1 C o o l d o w n 0 h 0 2 S t e p s a v e d The control will automatically advance to step three. The display will read: 0 1 C o o l d o w n 0 h 0 3 0i 0o 0: 0 0 Step three is typically an end step. To program an end step, press the The control will tell you that it is saving the step: key. 0 1 * * E n d * * 0 h 0 3 S t e p s a v e d Now, press the key to exit step editing mode and return to the formula list. 5.8 Exit Program Mode To exit the program mode, press the key. This will take you to the Manual Mode. Page 26 Section 5 Program Mode

27 6 Manual Mode 6.1 Entering Manual Mode If the password feature has not been enabled, press the key and proceed to step 4 below. Otherwise, start with step 1. Note: the factory default password is To change the control password, see Password, section on page 32. This example assumes that the control has been set up with the factory default password. If your password is different, use it instead. 1. Press the key. (example for the default password) The display will now read: P a s s w o r d 2. Press. The display will now read: P a s s w o r d * * * * 3. Press the key. The control will now be in the Program Mode, and the PRO light will be illuminated. 4. Press the key again. The control will now be in the Manual Mode, and the MAN light will be illuminated. 6.2 Active Keys Exits the Manual Mode and enters the Options Mode. Accesses the formula counters and hour meter. 6.3 Displays When you first enter the manual mode, the display will show: Section 6 Manual Mode Page 27

28 Dryer Control Operation Manual M a n u a l m o d e % On this screen, you see the actual inlet and outlet temperatures and the outlet humidity. On the bottom two lines of the display, you see the raw readings from the control s analog channels. These are available for troubleshooting purposes. 6.4 Reviewing Formula Counters 1. Press the key. The review hour meter/formula count section of the Manual Mode will be entered. The display will read: H o u r m e t e r 2 3 : 1 7 This shows the total hours of operation of the dryer. 2. Press the key. The display will read: 0 1 F o r m u l a 1 D a y 3 T o t a l This shows the two formula counters the day counter, which can be reset and used to keep track of the number of times the formula has been run recently, and the total counter, which contains the total number of times the formula has been run, which cannot be reset. (The day count, if not reset, will count 255 loads and then roll over and start at zero again. The total count, regardless of resets, will count to 65,535 loads and then roll over and start at zero. 3. Press, to advance to the next formula for review. 4. Press the key to exit the review hour meter/formula count section and return to the Manual Mode. NOTE: Formulas will only be displayed if they have been previously run. The total counter will not be reset. 6.5 Resetting Daily Counters 1. Press the key to enter the review hour meter/formula count section. Page 28 Section 6 Manual Mode

29 2. Press the key. The display will read Clear Daily Counters: No. Press the key to change option to YES. 3. Press to finalize reset of Load Counters for all formulas. 4. Press the key to exit the review hour meter/formula count section and return to the Manual Mode. 6.6 Exiting Manual Mode To exit the program mode, press the key. This will take you to the Options Mode. Section 6 Manual Mode Page 29

30 Dryer Control Operation Manual 7 Options Mode 7.1 Entering Options Mode If the password feature has not been enabled, press the key and proceed to step 4 below. Otherwise, start with step 1. Note: the factory default password is To change the control password, see Password, section on page 32. This example assumes that the control has been set up with the factory default password. If your password is different, use it instead. 1. Press the key. (example for the default password) The display will now read: P a s s w o r d 2. Press. The display will now read: P a s s w o r d * * * * 3. Press the key. The control will now be in the Program Mode, and the PRO light will be illuminated. 4. Press the key again. The control will now be in the Manual Mode, and the MAN light will be illuminated. 5. Press the key again. The control will now be in the Options Mode, and the OPT light will be illuminated. 7.2 Active Keys Sets the current option value to zero. Pressing the clear key twice restores the original setting. Saves the current option value. - Use these keys to enter numeric values for options. Selects the next option. Page 30 Section 7 Options Mode

31 Selects the previous option. Starts the process of editing the current option. Exits the options mode and returns to the run mode. 7.3 Option Settings Motor On Enter the time for the basket motor run time (used only by dry formulas programmed for reversing) Motor Off Enter the time for the basket motor pause (used only by dry formulas programmed for reversing) Signal On Enter the on time for the signal output. The valid range for this field is.1 seconds to 10 seconds, the smallest unit of change is.05 seconds. If a mechanical bell is connected, this field can be changed to 10 seconds and the next field, signal off time, can be changed to zero seconds, which will cause the control to ring the bell continuously Signal Off Enter the off time for the signal output. The valid range for this field is 0 seconds to 10 seconds, the smallest unit of change is.05 seconds. Changing this field to zero will cause the signal to ring without any pulsing Display Brightness Enter the number from the following chart to set the display brightness. 2- (25%) 5- (50%) 7- (75%) (Default setting ) 1- (100%) Changes to this field will take effect immediately Temperature Timeout Enter the time in minutes and seconds for the maximum allowable time for the dryer to come up to temperature. The default for this field is 10:00 minutes. The valid range for this field is zero to 25 minutes, the smallest unit of change is 15 seconds. This may cause some confusion if the user tries to set the time-out to 4:10 minutes, the dryer control will round this entry to 4:15 minutes. This field must be configured for proper control operation Allow Step Advance Press the key, to toggle between YES (enabled) or NO (disabled). If this feature is enabled, it will allow the operator to change steps during a formula, or to start a formula on a step other than step one. If this feature is disabled the step can still be changed if the machine has a supervisor key option. If the supervisor key option has not been configured consult a Factory Authorized Technician to setup this option. Section 7 Options Mode Page 31

32 Dryer Control Operation Manual Password Enter the password required for entry to the program, manual and options modes. The factory default for this field is It is recommended that the user change this field. If this field is set to 0 the password feature will be disabled. The operator may also enter the program and options modes with the use of the supervisor key, if this feature has been configured. If the supervisor key feature has not been configured consult a Factory Authorized Technician to set up the feature Chirp Time Enter the on time for the key chirp output. The valid range for this field is.05 seconds to.95 second, the smallest unit of change is.05 seconds. This feature may be disabled by setting this field to zero Low Temperature Enables the temperature interlock features of the dryer control. This feature keeps the door closed while the temperature of the machine is above the set value. The valid range for this field is 0 to 255 degrees Open Door Time On machines equipped with an automatic door, this setting is used to set the amount of time that it takes the door to go from fully closed to fully open. The valid range for this field is 0 to 255 seconds Raise Machine Time On machines equipped with a tilting basket, this setting is used to set the amount of time that it takes to go from the run position to the load or unload positions. The valid range for this setting is 0 to 255 seconds Humidity at Setpoint Time This setting is used to set the amount of time that the outlet humidity must be at setpoint before starting the step timer Inlet Temperature Limit This setting is used to set the maximum allowable inlet temperature. When this temperature is reached, the control will shut off the burner and start a cooldown cycle Outlet Temperature Limit This setting is used to set the maximum allowable inlet temperature. When this temperature is reached, the control will shut off the burner and start a cooldown cycle Wait for Temp. to Start Step Timer This setting is used to tell the dryer control that it should wait for the programmed inlet or outlet temperature to be achieved before starting the step timer Rotate Basket After Low Temperature This setting is used to tell the dryer control that it should continue rotating the basket after low temperature has been reached at the end of a cycle Keep Blowers On In End Step This setting is used to tell the dryer control that it should continue running the blowers when it reaches the end of the cycle. Pressing the off. key at the end of the cycle will turn the blowers Page 32 Section 7 Options Mode

33 Rotate Basket In End Step This setting is used to tell the dryer control that it should continue running the blowers when it reaches the end of the cycle. Pressing the off. key at the end of the cycle will turn the blowers Automatically Reset Display Modes This setting is used to tell the dryer control whether it should automatically return the time display to elapsed time a few seconds after the user has pressed the key to view programmed, step, or remaining time. If set to Yes, the control will automatically return to the elapsed time display and the actual inlet and outlet temperatures. If set to No, the display will remaining on whatever information was last viewed Set Up Service Alerts Press the key and enter the password (2007) and press the key. There are four sections in the service alerts, which are accessed by pressing the the key: Reset Service Alerts S e r v i c e i t e m # 1 1 I t e m 1 1 D u e a t : h r s C u r r e n t l y : h r s This tells the control that the maintenance has been performed, and sets a new due time for the item. The reset service alerts section displays the service alert name, the next number of hours that the item is due at, and the current number of hours of operation. Use the and keys to select the alert you wish to reset. To reset the alert, press the key when displaying the item you wish to reset. When finished, press the key to exit Edit Service Alerts S e r v i c e i t e m # 1 1 I t e m 1 1 A l e r h r s C r i t i c a h r s Section 7 Options Mode Page 33

34 Dryer Control Operation Manual This section edits service alert names and time intervals. To select the service alert you would like to edit, use the and keys. When the control is displaying the alert you wish to edit, press the key. The cursor will begin flashing on the first letter of the service alert name. Use the alphanumeric keys to enter the service alert name you wish to use, then press. The cursor will then flash on the number. Use the alphanumeric keys to enter the number of hours you want between alarms for this service item, and press. The cursor will then flash on the number. Use the alphanumeric keys to enter the number of hours you want to allow before the alert becomes critical - i.e., prevents the machine from running. Press when you are finished. Press to exit from this section Erase All Service Alerts This provides a convenient way to erase all service alert settings. When you select this function, the control will ask, Are you absolutely positive you want to clear service items? Use the key to select, then press items.. If you selected Yes, the control will clear all of your service Edit Service Alert Options This provides access to the various service alert options. a. Enable service items - activates/deactivates the service alerts Factory Options This is used to enter the factory options section. See manual section 8, page 35 for more information. 7.4 Exiting Options Mode To exit the options mode, press the key. This will take you to the Run Mode/Idle. Page 34 Section 7 Options Mode

35 8 Factory Options This section provides the information that controls proper setup and operations of your dryer. Only Qualified Service Personnel should change I/O assignments, as the safe operation of the washer may be effected. Failure to fully understand this data may result in the improper operation of the dryer and the dryer control. Incorrect setup may result in washer malfunctioning, which could result in personal injury, dismemberment or death. assumes no responsibility for improper use or setup of this unit. Contact a Factory Authorized Service Technician, to establish correct setup procedures. 8.1 Entering Factory Options If the password feature has not been enabled, press the key and proceed to step 4 below. Otherwise, start with step 1. Note: the factory default password is To change the control password, see Password, section on page 32. This example assumes that the control has been set up with the factory default password. If your password is different, use it instead. 1. Press the key. (example for the default password) The display will now read: P a s s w o r d 2. Press. The display will now read: P a s s w o r d * * * * 3. Press the key. The control will now be in the Program Mode, and the PRO light will be illuminated. 4. Press the key again. The control will now be in the Manual Mode, and the MAN light will be illuminated. 5. Press the key again. The control will now be in the Options Mode, and the OPT light will be illuminated. 6. Now, press the key until Factory Options is shown on the display. Press the key. The control will ask for a password, type in 1206 and press. Section 8 Factory Options Page 35

36 Dryer Control Operation Manual 8.2 Active Keys Selects the next option. Selects the previous option. Enters the currently selected submenu. Exits the options mode and returns to the run mode. 8.3 I/O Assignments To edit the I/O Assignments, follow the directions for entering the factory options in section 8.1, Entering Factory Options, on page 35. Once in the factory options section, select I/O Assignments and press the key. Once in the I/O Assignments section, the display will show: (note that your display may be slightly different, based on your machine s configuration) I / O A s s i g n m e n t 1 L 0 R 0 I 0 T 0 The top line shows the I/O Assignment number, while the second line shows each of the four settings associated with an I/O Assignment the LED, Relay, Input and Type. The LED setting tells the control which light on the front panel to illuminate when the machine function is active. The Relay setting tells the control which relay on the I/O board to activate to operate the machine function. The Input assignment tells the control which input on the I/O board to look at. The Type assignment allows the control to use machine functions in different ways. To edit an I/O assignment, press the assignment: key. The cursor will begin flashing on the LED I / O A s s i g n m e n t 1 L 0 R 0 I 0 T 0 Use the number keys to enter the desired LED, then press the setting. The cursor will begin flashing on the Relay setting: key to move to the Relay Page 36 Section 8 Factory Options

37 I / O A s s i g n m e n t 1 L 1 R 0 I 0 T 0 Use the number keys to enter the desired relay, then press the setting. The cursor will begin flashing on the Input setting: key to move to the Input I / O A s s i g n m e n t 1 L 1 R 1 I 0 T 0 Use the number keys to enter the desired input, then press the setting. The cursor will begin flashing on the Type setting: key to move to the Type I / O A s s i g n m e n t 1 L 0 R 0 I 0 T 0 Use the number keys to enter the desired type, then press the key to store the settings. At this point, you can select another I/O Assignment using the and keys. When finished editing the I/O Assignments, press the list. key to return to the Factory Options Section 8 Factory Options Page 37

38 Dryer Control Operation Manual High Fire LED: Enter the number corresponding to the high fire LED. Relay: Enter the number corresponding to the high fire relay. The dryer control will energize this output when it wants to open the high fire gas valve. A relay must be assigned to this I/O Assignment to enable heat. Input: This field is not currently used Low Fire LED: Enter the number corresponding to the low fire LED. Relay: Enter the number corresponding to the low fire relay. The dryer control will energize this output when it wants to open the low fire gas valve. Input: This field is not currently used Recirculation LED: Enter the number corresponding to the recirculation damper LED. Relay: Enter the number corresponding to the recirculation damper relay. The dryer control will energize this output when it wants to activate the recirculation damper. Input: This field is not currently used Signal LED: Enter the number corresponding to the signal LED. Relay: Enter the number corresponding to the signal relay. If the piezo signal output from the back of the dryer control is used this field may be changed to zero. Additional fields in the options list should also be reviewed for setting the signal on and signal off times. Input: Enter the number corresponding to the signal input. This input is normally floating high, connecting this input to the input common will acknowledge the signal. Type: 0: The chirp output will sent to the CPU output and the relay output. 1: The chirp output will not be sent to the relay assignment Basket Forward LED: Enter the number corresponding to the basket forward LED. Relay: Enter the number corresponding to the motor forward starter relay. Input: This field is not currently used Basket Reverse LED: Enter the number corresponding to the motor reverse LED. Relay: Enter the number corresponding to the motor reverse start relay. Input: This field is not currently used (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) Page 38 Section 8 Factory Options

39 (Not Used) Auxiliary 1 LED: Enter the number corresponding to the auxiliary output LED. Relay: Enter the number corresponding to the auxiliary output relay. Input: This field is not currently used. Type: 0: This output will turn off if the dryer control is stopped while running a formula. 1: This output will remain on if the dryer control is stopped while running a formula Auxiliary 2 LED: Enter the number corresponding to the auxiliary output LED. Relay: Enter the number corresponding to the auxiliary output relay. Input: This field is not currently used. Type: 0: This output will turn off if the dryer control is stopped while running a formula. 1: This output will remain on if the dryer control is stopped while running a formula Auxiliary 3 LED: Enter the number corresponding to the auxiliary output LED. Relay: Enter the number corresponding to the auxiliary output relay. Input: This field is not currently used. Type: 0: This output will turn off if the dryer control is stopped while running a formula. 1: This output will remain on if the dryer control is stopped while running a formula Auxiliary 4 LED: Enter the number corresponding to the auxiliary output LED. Relay: Enter the number corresponding to the auxiliary output relay. Input: This field is not currently used. Type: 0: This output will turn off if the dryer control is stopped while running a formula. 1: This output will remain on if the dryer control is stopped while running a formula Gas Blower LED: Enter the number corresponding to the gas blower LED. Relay: Enter the number corresponding to the gas blower relay. The dryer control will energize this output when running the gas blower during a dry step. Input: This field is not currently used Exhaust Blower LED: Enter the number corresponding to the exhaust blower LED. Relay: Enter the number corresponding to the exhaust blower relay. The dryer control will energize this output when running the exhaust blower during a dry step. Input: This field is not currently used Lint Blowdown LED: Enter the number corresponding to the lint blowdown LED. Relay: Enter the number corresponding to the lint blowdown relay. The dryer control will energize this output for the amount of time set in the Lint Trap Blowdown Time option, section , page 53. The control can be set up to blow down the lint trap at various times, including at the beginning of the formula, end of formula, whenever the control is Section 8 Factory Options Page 39

Revised 12/14/2001. DC-5500 DC-5750 Operation Manual

Revised 12/14/2001. DC-5500 DC-5750 Operation Manual Revised 12/14/2001 DC-5500 DC-5750 Operation Manual Operation Configuration Troubleshooting Custom Control Systems Inc. 2007 Beech Grove Place Utica, NY 13501 (315) 732-1990 www.customcontrolsystems.com

More information

Revised 10/3/2002. Ellis Intellitrol Washer Control Operation Manual

Revised 10/3/2002. Ellis Intellitrol Washer Control Operation Manual Revised 10/3/2002 Ellis Intellitrol Washer Control Operation Manual Operation Configuration Troubleshooting Ellis Intellitrol Custom Control Systems Inc. 2007 Beech Grove Place Utica, NY 13501 (315) 732-1990

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12 AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RST-5000 Series Web Enabled Input Module Rev. A2, 1/12 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com RST-5000

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

MicroPulse Dryer Northpoint Parkway Acworth, GA

MicroPulse Dryer Northpoint Parkway Acworth, GA MicroPulse Dryer 1100 Northpoint Parkway Acworth, GA 30102 770.974.2700 www.softrol.com MICROPULSE DRYER This Page has been intentionally left blank. micropulse Dryer Contents MICROPULSE DRYER 1. Introduction

More information

Chore-Tronics Load Cell Indicator

Chore-Tronics Load Cell Indicator Chore-Tronics Load Cell Indicator June 2008 CTB Inc. Warranty Load Cell Indicator CTB Inc. Warranty CTB Inc. warrants each new product manufactured by it to be free from defects in material or workmanship

More information

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will The formation Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will be working on the Blodgett XR8 Oven. All other uses are

More information

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System. The Fireye EP260, EP270 (early spark termination), or EP265 (pilot stabilization) programmer modules are used with the FLAME-MONITOR Burner Management Control System (P/N E110). Several operational characteristics

More information

Inline Heater for Solvent or Gas. Installation and Operation Manual

Inline Heater for Solvent or Gas. Installation and Operation Manual SH Series Inline Heater for Solvent or Gas Installation and Operation Manual This instruction manual explains the basic operation of the Process Technology inline solvent or gas heater. We recommend reading

More information

Protégé Eclipse LED Keypad User Manual PRT-KLES

Protégé Eclipse LED Keypad User Manual PRT-KLES Protégé Eclipse LED Keypad User Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide System Reset Trou ble Silence Ala rm Silence Manual Ala rm ENTER NO YES Letters Numb ers Keyword Radionics System Reset Trouble Silence Alarm Silence Manual Alarm ENTER NO YES Le ters Numbers Keyw ord

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 3100 Premier Series Non-Programmable 2 Heat / 2Cool & Heat / Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL Model TME- * * Balance of model number is determined by customer specifi ed limits and Setbacks. AUTOMATIC SETBACK THERMOSTAT LIGHT SENSING OR CONTACT CLOSURE FOR LOW VOLTAGE

More information

CA5000 Liquid CO 2 Freezer Backup System

CA5000 Liquid CO 2 Freezer Backup System CA5000 Liquid CO 2 Freezer Backup System OPERATING INSTRUCTIONS MANUAL HAMPSHIRE CONTROLS CORPORATION ONE GROVE STREET / P.O. BOX 516, DOVER, NEW HAMPSHIRE USA 03821 TEL. (603) 749-9424 FAX (603) 749-9433

More information

Operating manual. Wascator FOM71 CLS

Operating manual. Wascator FOM71 CLS Operating manual Wascator FOM71 CLS Operating manual in original language 438 9200-91/EN 2010.05.03 Register now And be able to join the Wascator FOM 71 CLS web site where you can find: General information

More information

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump

More information

VX SERIES Wireless Thermostat with Occupancy Sensor

VX SERIES Wireless Thermostat with Occupancy Sensor VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat

More information

Digital Programmable

Digital Programmable www.geappliances.com Digital Programmable Thermostats Operating Instructions Auto Changeover..........10 Day/Time Setting Mode.....6 Default Mode...............4 Fan Control...............10 Hold and Temporary

More information

HB CDA SERIES WITH TEMPERATURE SETBACK

HB CDA SERIES WITH TEMPERATURE SETBACK HB CDA SERIES WITH TEMPERATURE SETBACK 2013 NOVATEC, Inc. All Rights Reserved Document: HB CDA IM 7-24-2013 NOTES: Please record the following information, which is specific to this piece of equipment,

More information

Service Manual Models: 1.0, 1.3, and 1.5

Service Manual Models: 1.0, 1.3, and 1.5 AWX2-SER_100160837_2000000360_Rev F Service Manual Models: 1.0, 1.3, and 1.5 LOW LEAD CONTENT WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions,

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5211 2-Stage Heat Pump Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat Pump Systems Large Display With Backlight Selectable

More information

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01 ProTalk Expander Operating Manual Model B1292 July 28, 2009 Rev. 1.01 TABLE OF CONTENTS 1. Introduction... 1 2. Installation... 2 2.1 Wiring Diagram... 3 3. Operations... 4 4. Programming (B1225 Mode)...

More information

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC WIRING DIAGRAMS R410A MODELS 2OAC/2OACH PAC CAC PWC OWC WIRING 02172017 TABLE OF CONTENTS PAGE 2OACH Deluxe Portable Air-cooled Heat Pump Electronic Controller... 2-3 Piping Schematic... 4 Single Phase

More information

JDDT1 - Single Stage Digital Thermostat

JDDT1 - Single Stage Digital Thermostat JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET

More information

7-Day. Digital Thermostat. residential. & 2-cool

7-Day. Digital Thermostat. residential. & 2-cool Digital Thermostat residential THERMOSTAT T1100FS 7-Day PROGRAMMABLE up to 2-heat & 2-cool PUMP Control up to 2 Heat & 2 Cool Stages 7-Day Programmable 4 Settings/Day Auto Changeover 5 minute Built-In

More information

Operating, Installation and Service Manual W3400H, CLC 41 Clarus Control

Operating, Installation and Service Manual W3400H, CLC 41 Clarus Control Operating, Installation and Service Manual W3400H, CLC 41 Clarus Control 438 9202-01 05.26 Washer extractor, drum volume 400 litres 3 Contents Machine operation... 7 General description... 7 Automatic

More information

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12 CAREL ir33 Quick reference Handbook Pag.1/12 MAIN FEATURES OF THE INSTRUMENT USER INTERFACE 1. ON/OFF switch button UP button to increase temperature values 2. DOWN button to decrease values - Activates/deactivates

More information

PRESSURA ROOM PRESSURE CONTROLLER MODELS 8630-SC 8630-PC

PRESSURA ROOM PRESSURE CONTROLLER MODELS 8630-SC 8630-PC PRESSURA ROOM PRESSURE CONTROLLER MODELS 8630-SC 8630-PC OPERATION AND SERVICE MANUAL P/N 1980243, REVISION J DECEMBER 2013 PRESSURA ROOM PRESSURE CONTROLLER MODELS 8630-SC 8630-PC OPERATION AND SERVICE

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

Static Pressure Control

Static Pressure Control The (model SPC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The SPC-2 automatically controls the pressure in a room by operating a

More information

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a

More information

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788 PNEUMERCATOR Liquid Level Control Systems LEAK/POINT LEVEL ALARM CONSOLE OPERATION MANUAL DRAWING NO. 20068 REV. N/C MODEL COPYRIGHT 2017 PNEUMERCATOR CO., INC. 1785 EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY

More information

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

Operating Instructions READ AND SAVE THESE INSTRUCTIONS Operating Instructions READ AND SAVE THESE INSTRUCTIONS Aprilaire Communicating Thermostat Model 8870 CAUTION: Do not set to OFF mode during periods when freezing temperatures could occur. Thank you for

More information

DAY/TIME Button: Selects hour, minute and day setting.

DAY/TIME Button: Selects hour, minute and day setting. MODEL 5300 USER MANUAL READ ALL INSTRUCTIONS BEFORE PROCEEDING For more information on energy savings, go to www.energystar.gov Premier Series Universal Auto Changeover Thermostat Up to 2 Heat / 2 Cool

More information

General The Dryer Programmer for Windows Computers

General The Dryer Programmer for Windows Computers Published Manual Number: MQYDSB01 Specified Date: 20131120 As-of Date: 20131120 Access Date: 20131120 Depth: Detail Custom: n/a Applicability: YDS Language Code: ENG01, Purpose: publication, Format: 1colA

More information

INSTRUCTION MANUAL P Heating and 1 Cooling

INSTRUCTION MANUAL P Heating and 1 Cooling REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:

More information

G34 AU1B (External Ultrasonic Sensor) Version 3

G34 AU1B (External Ultrasonic Sensor) Version 3 Car Alarm Series 3 B 4 Buttons G34 AU1B (External Ultrasonic Sensor) Version 3 24 CAR ALARM GENIUS Series 3B 4 Buttons G34 AU1B (External Ultrasonic Sensor) Module controlled using Micro-Processor 2 Transmitters

More information

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL Operation Manual Celltrol II Bioreactor Control System Page 1 of 33 Table of Contents 1) Introduction... 3 1.1) Scope of Document... 3 1.2) Control System Overview... 3 1.3) Introduction to Celltrol II...

More information

FUME HOOD MONITOR ALNOR AIRGARD 335

FUME HOOD MONITOR ALNOR AIRGARD 335 FUME HOOD MONITOR ALNOR AIRGARD 335 OWNER S MANUAL P/N 116159255, REV 10 SEPTEMBER 2014 LIMITATION OF WARRANTY AND LIABILITY (effective April 2014) (For country-specific terms and conditions outside of

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

1 For All Programmable Digital Thermostat

1 For All Programmable Digital Thermostat OWNER'S MANUAL P/N P374-2300FM 1 For All Programmable Digital Thermostat Am OFF OVERRIDE Meets California Title 24 unts flush to the wall 7 Day Programmable 3 Occupied, 1 Unoccupied Auto-Changeover Large,

More information

Installation, Configuration and User Manual

Installation, Configuration and User Manual Model 8826 System Controller Model 8826 System Controller Installation, Configuration and User Manual READ AND SAVE THESE INSTRUCTIONS WELCOME Thank you for choosing the Aprilaire HVAC Automation System.

More information

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool

More information

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A Installation & Service Manual S E C T I O N 26 Enviroguard III ENVIROGUARD III is a patented refrigerant control system that utilizes floating head technology (Nature s Cooling). The amount of liquid refrigerant

More information

For Quick Set-Up go to Page 14

For Quick Set-Up go to Page 14 Talking Thermostat Model VT3000 Guide SmartWay Solutions, Inc. US Patent 6,608,560 & 7,62,253 For Quick Set-Up go to Page 4 Model VT3000, a universal thermostat for use on most Gas or Electric, Conventional

More information

SPECTRA 1727 USER S GUIDE

SPECTRA 1727 USER S GUIDE SPECTRA 1727 USER S GUIDE TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 BASIC OPERATION... 4 2.1 Auditory Feedback...4 2.2 Keypad Indicator Lights...6 2.3 Zone Display...6 2.4 Alarm Memory Display...6 3.0

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B 2 CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B CAUTION CAUTION - ONLY TRAINED, QUALIFIED PERSONNEL SHOULD INSTALL AND/OR SERVICE CLIMATEMASTER EQUIPMENT. SERIOUS

More information

VS2000V Veterinary Vital Signs Monitor Operation Manual

VS2000V Veterinary Vital Signs Monitor Operation Manual VS2000V Veterinary Vital Signs Monitor Operation Manual - English Version 1.0, July 2011 2011 UTECH Co., Ltd. All rights reserved. Table of Contents Table of Contents Warranty and Service Information...

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

Owner s Manual. Digital Thermostat

Owner s Manual. Digital Thermostat Model Air Conditioning & Heating Heat Pump 5+2 Day Programmable Digital Thermostat Control up to 2-Heat & 1-Cool Battery or System Powered Backlit Digital Display Auxiliary Heat Indicator Fahrenheit or

More information

DAY/TIME Button: Selects hour, minute and day setting.

DAY/TIME Button: Selects hour, minute and day setting. CONTENTS MODEL 5400 USER MANUAL READ ALL INSTRUCTIONS BEFORE PROCEEDING For more information on energy savings, go to www.energystar.gov Premier Series Universal Auto Changeover Thermostat Up to 3 Heat

More information

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING MODEL Premier Series 3000 USER MANUAL Non-Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department

More information

Installation Instructions

Installation Instructions P700U -21NHP Base Non -Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A14005 Base Non---Programmable Thermostat

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7

More information

Model SS2000C31 SmartSystem Load Management System

Model SS2000C31 SmartSystem Load Management System Model SS00C31 SmartSystem Load Management System LOAD MANAGER WITH ELECTRONIC SIREN/LIGHT CONTROL SYSTEM AND DIRECTIONAL LIGHT (with Slide Switch Control Head) OPERATION AND CONFIGURATION INSTRUCTIONS

More information

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1070 NON- PROGRAMMABLE 2 OR 4 PIPE SYSTEMS Remote sensor ready 3 speed fan control Self-prompting adjustment Auto 2-pipe changeover when used with ACC-SENFC

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM D-tect Systems 11814 South Election Road, Suite 200 Draper, UT 84020 www.dtectsystems.com 1 Introduction The mini

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

CT224 Setup Tutorial

CT224 Setup Tutorial CT224 Setup Tutorial Table of Contents 1. Introduction 2. Configuring Controller for Operation A. Example 1 Over Temp Operation with Hysteresis @ 5º F. B. Example 2 Under Temp Operation with Hysteresis

More information

MICROPROCESSOR CONTROLLER OPERATION AND MAINTENANCE MANUAL February 1, 2002

MICROPROCESSOR CONTROLLER OPERATION AND MAINTENANCE MANUAL February 1, 2002 MICROPROCESSOR CONTROLLER OPERATION AND MAINTENANCE MANUAL February 1, 2002 This manual provides information for installation, operation and preventive maintenance. The user should observe the guidelines

More information

WARNING Important Safety Information

WARNING Important Safety Information Builder Series Non-Programmable Thermostats MODEL 1000 MODEL 0 1 2 3 4 Single Stage Heat / Cool Conventional and Heat Pump Multi-Stage 2 Heat / 1 Cool Conventional and Heat Pump Before Installing, Programming

More information

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1075 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS 3 Occupied, 1 Unoccupied Override capable 3 speed fan control Auto 2-pipe changeover when used with accessory

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc. CEMS Operating Manual IMR USA S/N: Sample IMR 5000 IMR 400 IMR 400 IMR 5000 Measure MESURE PURGE Purge CALIBRATE Calibrate OFF OFF RESET Measure ON ON Calibrate RESET PUMP Gas Dryer Inside PUMP Sensors

More information

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling INSTRUCTION MANUAL TS21 2 Heating and 1 Cooling WELCOME TO Flexible applications - Universal and easy to install in residential or commercial environments. Advanced features - Precision electronics provide

More information

Programmable HEPA Air Purifier

Programmable HEPA Air Purifier Programmable HEPA Air Purifier Model 30130 Models 30170, 30175 & 30185 Model 30130 30170, 30175, 30185 30400, 30401 Model 30400 & 30401 Replacement Filter Information Pre-Filter 30901 30901 30901 www.hunterfan.com

More information

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Owner s Manual. 5+2 Day Programmable Digital Thermostat Model Air Conditioning & Heating 5+2 Programmable Digital Thermostat 1-Heat & 1-Cool Heat Pump Compatible Battery or System Powered Backlit Digital Display Fahrenheit or Celsius Service Filter Indicator

More information

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat T6 Pro Hydronic Programmable Thermostat User Guide Package Includes: T6 Pro Hydronic Programmable Thermostat Floor sensor (model AQ12C20) UWP Mounting System Honeywell Standard Installation Adapter (J-box

More information

WARNING Important Safety Information

WARNING Important Safety Information Builder Series Non-Programmable Thermostat MODEL 00NC Heat Only or Cool Only Thermostat Before Installing, Programming or Operating, PLEASE READ ALL INSTRUCTIONS Specifications Temperature Adjustment WARNING

More information

5+2 Day. up to HEAT COOL

5+2 Day. up to HEAT COOL Digital Thermostat residential THERMOSTAT T1050 5+2 Day PROGRAMMABLE up to 2-heat & 2-cool PUMP Control up to 2 heat & 2 Cool Stages 4 Settings Per Day Self-prompting programming Auto changeover Separate

More information

PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND RPM20

PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND RPM20 PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND OPERATION AND SERVICE MANUAL P/N 6006644, REVISION J JULY 018 PRESSURA ROOM PRESSURE CONTROLLER MODEL RPM10 AND OPERATION AND SERVICE MANUAL P/N 6006644,

More information

AirGard 385 Fume Hood Monitor

AirGard 385 Fume Hood Monitor OWNER S MANUAL AirGard 385 Fume Hood Monitor A TSI Company AIRGARD 385 MONITOR SPECIFICATIONS Digital Display Display Units 3 digit, 7-segment liquid crystal display. Feet per minute () or meters per second

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 5100 Premier Series 7-Day Programmable 2-Heat / 2-Cool Heat /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages

More information

Dryer Master DM510 Commissioning Guide

Dryer Master DM510 Commissioning Guide COMMISSIONING GUIDE Dryer Master DM510 Dryer Moisture Systems Inc. 640 Superior Drive Waterloo, Ontario Phone 519.725.4700 Fax 519.885.4300 USA & Canada Toll Free 1-888-318-0009 E-mail: info@dryermaster.com

More information

Introduction. OM-THA2

Introduction. OM-THA2 Introduction. The OM-THA2 is a multi-function product that monitors Temperature, Humidity and Dew Point, provides alarms for out of range conditions, and continuously logs data. It consists of a base unit

More information

Henny Penny Electronic Bun Warmer Model BW-1 Model BW-4 Model BW-4 Model BW-4/3 Model BW-6 Model BW-8

Henny Penny Electronic Bun Warmer Model BW-1 Model BW-4 Model BW-4 Model BW-4/3 Model BW-6 Model BW-8 Henny Penny Electronic Bun Warmer Model BW-1 Model BW-4 Model BW-4 Model BW-4/3 Model BW-6 Model BW-8 SERVICE MANUAL LIMITED WARRANTY FOR HENNY PENNY EQUIPMENT Subject to the following conditions, Henny

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications 1 2 3 4 5 Builder Series Programmable Thermostats 2000 2000NC 2200 2200NC Single Stage Heat / Cool Conventional and Heat Pump Multi-Stage 2 Heat / 1 Cool Conventional and Heat Pump Before

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Part No. 4028539 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications Premier Series Non-Programmable Thermostats MODEL 3000 MODEL 3200 1 2 3 4 Specifications Installation Testing Your New Thermostat Programming User Settings WARNING Important Safety Information

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 3000 Premier Series Non-Programmable Single Stage /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

6 CUFT BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and and

6 CUFT BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and and 6 CUFT BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL FOR MODELS 6400-1 and 6400-4 6404-1 and 6404-4 PO Box 715 Marietta, OH 45750 800-648-3042 740-373-6809 Fax 740-374-3760 www.caronproducts.com service@caronproducts.com

More information

48040M7K, 68036M5K, 72046M5K + Dryell

48040M7K, 68036M5K, 72046M5K + Dryell Published Manual Number/ECN: MQCLCO01U1/2017096A Publishing System: TPAS2 Access date: 03/03/2017 Document ECNs: Latest 48040M7K, 68036M5K, 72046M5K + Dryell POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400,

More information

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual 026-1503 Rev 0 3-20-03 Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319

More information

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information Model 8800 Universal Communicating Thermostat Owner s Manual Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS 61000762A 8800 Tstat Owners.indd 1 3/28/11 4:19:57

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS SPECIALTY REFRIGERATED TRANSPORT CABINETS FOR SATELLITE LOCATIONS RBQ-96 Caution: Read the instructions before using the machine. CONGRATULATIONS......and thank you for purchasing

More information

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode) INSTALLATION INSTRUCTIONS DUAL AIR INTAKE 2650-1847-77 USE TEFLON SEALING TAPE OR SEALING COMPOUND ON PIPE THREADS OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Pro Control Output

More information

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the

More information