45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:
|
|
- Percival Hubbard
- 5 years ago
- Views:
Transcription
1 SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM
2 SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart Zone Diffuser is used to vary the supply air volume from a wall-mounted thermostat. The diffuser is designed to maintain the coanda effect (draft free) of discharge air along the ceiling, providing a sustained discharge velocity throughout the volume range. The Smart Zone VAV Diffuser with a S-T, P+I zone thermostat. AVAILABLE SIZES: Face Size: X (.7 x.7 ).7 Neck Size: 6, 8 for x face size 6, 8, 0,, for x face size CONSTUCTION: Face Plate: Back Cone: OPEATION: emovable 8 gauge steel with baked white enamel finish Unitary stamped 8 gauge steel T T Diffuser: Integral modulating disk that continually regulates supply air volume in response to thermostat control Air Volume ange: 8 to 70 CFM TOP VIE DIFFUSE ACTUATO: VAC, VA, -wire floating point actuator A. COMPONENTS: Diffuser, actuator, PC board and discharge air sensor AI HANDLE CONTOL: Space thermostat Discharge air controller SIDE VIE AANT: ears Drawings are intended to show general, overall product dimensions and provide guidance for installation clearance. Drawings are not to scale. Performance Air Products, Inc. reserves the right to make product changes without notification or obligation.
3 ENGINEEING DATA SMAT ZONE x SE-HC/M VAV Diffuser Part Number Neck Velocity (FPM) and Neck Size Velocity Pressure Airflow (CFM) SE-HC-06-M Total Pressure Ak = 0.9 Horizontal Throw Noise Criteria < < < < < < 7 8 Airflow (CFM) SE-HC-08-M Total Pressure Ak=0.6 Horizontal Throw Noise Criteria < < < < < 7 8 Airflow (CFM) SE-HC-0-M Total Pressure Ak=0. Horizontal Throw Noise Criteria < < < < 0 8 Airflow (CFM) SE-HC--M Total Pressure Ak=0.0 Horizontal Throw Noise Criteria < < < < Airflow (CFM) SE-HC--M Total Pressure Ak=0. Horizontal Throw Noise Criteria < < < < Notes:. Tests conducted in accordance with ANSI/ASHAE at isothermal conditions.. Tests conducted with a straight rigid inlet condition. Other inlet conditions may alter performance.. Units: Total Pressure = in. wc; Velocity Pressure -= in. wc; Effective Area (Ak) = ft.².. Throw - feet at 0 fpm, 00 fpm and 0 fpm terminal velocities. -. NC is based upon 0dB room absorption (e: 0 watts) evaluated at thru 000 Hz octave bands. 6. Flow hoods are recommended for system balancing.
4 SMAT ZONE S-T SMAT THEMOSTAT MODULATING ZONE THEMOSTAT ITH AUTO CHANGEOVE DISASSEMBLING THEMOSTAT Insert a small coin (dime) into the release slot located on the bottom of the thermostat. Gently twist the coin to release the thermostat from the subbase. Avoid twisting the case as this may stress the LCD and cause it to crack or bend the wiring terminal connection pins. SITCH FUNCTIONS There are eight dip switches located on the thermostat PC board. Only dip switches, and are active. SITCH - Switch is used to lock the thermostat after setup is completed. hen the thermostat is locked (ON position) a padlock icon will show on the LCD. hen locked, only setpoint changes and status functions can be accessed by the user. Do not set Switch in the ON position until all SETUP functions are completed. SITCH - Switch is used to display the space temperature and setpoint in Celsius (ON position) or Fahrenheit (OFF position). Select Celsius or Fahrenheit before proceeding to the thermostat SETUP menu. SITCH - Switch is used to select twoposition (ON) or fully modulating (OFF) damper control to best suit the specific application requirement. KE FUNCTIONS ON/OFF KE - hen the S-T is not locked, this key allows the thermostat to be turned ON or OFF. hen in the OFF position, the damper is also driven closed STATUS KE - Pressing the STATUS key displays the UNIT number, ZONE number, DUCT temperature and DAMPE position. UP/DON KES - These keys are used to increase or decrease the setpoint as well as change thermostat setup values. ENTE KE - This key is used to enter changes as well as exit the setup menu. (efer to Installation / Operation Manual for complete setup instructions) OPEATION The duct sensor wired to the S-T is designed to select the mode of operation of the damper. If the discharge air temperature is above 7 F, the damper will open on a call for heating. If the discharge air temperature is below 7 F, the damper will open on a call for cooling TEMINAL DESIGNATIONS C Vac (Common) Vac (Hot) PO Power Open PC Power Close () Duct Sensor Cooling elay Heating elay A / B Modbus Communications FACTO DEFAULT SETTINGS Minimum Heating Damper Position 0% Minimum Cooling Damper Position 0% Maximum Damper Position 00% Unit Number 00 Zone Number 00 Heating Limit 76 F Cooling Limit 68 F Actuator Speed 90 Modbus Address 0 Temperature Calibration Offset 0
5 APPLICATION: SMAT ZONE SE-HC/S, Type LT, Lay-in, T-Bar, VAV Fully Modulating Auxiliary Diffuser Specifications The Model SE-HC/S VAV Smart Zone Diffuser includes a diffuser and modulating actuator. The SE-HC/S can be used as an auxiliary damper when wired to a SE-HC/S diffuser actuator in applications where more than one diffuser is required in a single zone. AVAILABLE SIZES: Face Size: X (.7 x.7 ).7 Neck Size: 6, 8 for x face size 6, 8, 0,, for x face size CONSTUCTION: Face Plate: Back Cone: OPEATION: Diffuser: emovable 8 gauge steel with baked white enamel finish Unitary stamped 8 gauge steel Integral modulating disk that continually regulates supply air volume in response to thermostat control.7 Air Volume ange: 8 to 70 CFM TOP VIE DIFFUSE ACTUATO: VAC, VA, -wire floating point actuator A. COMPONENTS: Diffuser and actuator AI HANDLE CONTOL: SIDE VIE Space thermostat Discharge air controller AANT: ears Drawings are intended to show general, overall product dimensions and provide guidance for installation clearance. Drawings are not to scale. Performance Air Products, Inc. reserves the right to make product changes without notification or obligation.
6 ENGINEEING DATA Smart Zone x SE-HC/S Auxiliary VAV Diffuser Part Number Neck Velocity (FPM) and Neck Size Velocity Pressure Airflow (CFM) SE-HC-06-S Total Pressure Ak = 0.9 Horizontal Throw Noise Criteria < < < < < < 7 8 Airflow (CFM) SE-HC-08-S Total Pressure Ak=0.6 Horizontal Throw Noise Criteria < < < < < 7 8 Airflow (CFM) SE-HC-0-S Total Pressure Ak=0. Horizontal Throw Noise Criteria < < < < 0 8 Airflow (CFM) SE-HC--S Total Pressure Ak=0.0 Horizontal Throw Noise Criteria < < < < Airflow (CFM) SE-HC--S Total Pressure Ak=0. Horizontal Throw Noise Criteria < < < < Notes:. Tests conducted in accordance with ANSI/ASHAE at isothermal conditions.. Tests conducted with a straight rigid inlet condition. Other inlet conditions may alter performance.. Units: Total Pressure = in. wc; Velocity Pressure -= in. wc; Effective Area (Ak) = ft.².. Throw - feet at 0 fpm, 00 fpm and 0 fpm terminal velocities. -. NC is based upon 0dB room absorption (e: 0 watts) evaluated at thru 000 Hz octave bands. 6. Flow hoods are recommended for system balancing.
7 SMAT ZONE MODULATING STAND-ALONE ZONE DAMPE ASSEMBL S-T AUTO CHANGEOVE SPACE THEMOSTAT PO PC C DAMPE OPEN DAMPE CLOSED CALL FO HEAT VAC POE (HOT) VAC POE (COM.) DUCT SENSO DUCT SENSO CALL FO COOL FACTO JUMPE C ACTUATO BOAD OPEN CLOSED COM. ED LED INDICATES A CALL FO HEATING HEAT COOL GEEN LED INDICATES A CALL FO COOLING DAMPE O DIFFUSE ACTUATO PUPLE OANGE ED 90 SECOND TIMING 90 STOKE lb.-in. VA VAC POE DUCT SENSO (0 K ) IE TO OPTIONAL SLAVE DAMPE (UP TO 0 MA BE IED IN PAALLEL) SEQUENCE OF OPEATION: The automatic changeover duct sensor (located on the Smart Zone damper) senses whether there is warm air or cool air in the duct. If the S-T Smart Thermostat is calling for cooling and the duct sensor determines there is cool air in the duct, the damper will modulate open. If the S-T Smart Thermostat is calling for heating and the duct sensor determines there is warm air in the duct, the damper will modulate open. The green LED located on the actuator board indicates when the space temperature is. F above the thermostat setpoint and the thermostat is calling for cooling. The red LED located on the actuator board indicates when the space temperature is. below the thermostat setpoint and the thermostat is calling for heating. APPLICATION AND INSTALLATION NOTES: Use standard 8 gauge thermostat wire. A VAC 0 VA transformer will power a single Smart Zone system and up to 0 actuators. The actuator board is located on the side of the actuator. If the duct temperature is above 7 F, the zone damper will open on a call for heating. If the duct temperature is below 7 F, the zone damper will open on a call for cooling. If a single Smart Zone system or multiple Smart Zone systems are used to zone more than 0% of the total CFM served by the HVAC system, a bypass damper may be required to maintain constant system static pressure. The HVAC system should be controlled by its own space thermostat or discharge air controller. If a space thermostat is used to control the HVAC system, it must never be located in an area served by a Smart Zone. A suction line freeze stat (FS-8) should be installed when zoning more than 0% of the total CFM served by the HVAC system to protect the equipment in the event the suction line temperature drops too low (ire in series with the cooling control circuit).
8 SMAT ZONE MODULATING STAND-ALONE ZONE DAMPE ASSEMBL IING DIAGAM FO ZONE HAVING AN ELECTIC DUCT HEATE S-T AUTO CHANGEOVE SPACE THEMOSTAT PO PC C DAMPE OPEN DAMPE CLOSED CALL FO HEAT VAC POE (HOT) VAC POE (COM.) DUCT SENSO DUCT SENSO CALL FO COOL EMOVE FACTO JUMPE C ACTUATO BOAD OPEN CLOSED COM. ED LED INDICATES A CALL FO HEATING HEAT COOL GEEN LED INDICATES A CALL FO COOLING DAMPE O DIFFUSE ACTUATO PUPLE OANGE ED 90 SECOND TIMING 90 STOKE lb.-in. VA VAC POE IE TO ELECTIC DUCT HEATE ELA COIL DUCT SENSO (0 K ) IE TO OPTIONAL SLAVE DAMPE (UP TO 0 MA BE IED IN PAALLEL) - ELA V COIL ELA NC C NO K Ohm esistor SSTEM NOTES: 8 gauge plenum-rated thermostat wire is recommended. A VAC 0 VA transformer is required to power thermostat and actuator. A K Ohm resistor must be wired to - relay contacts and paralleled with the duct sensor. The relay coil is wired to terminals and on the actuator board. hen the thermostat call for heating, the relay coil will be energized and the resistor will change the ohms value translating to a higher duct temperature which will drive the damper open. The electric duct heater relay coil can be wired to the actuator board and terminals. emove factory jumper as illustrated.
Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0
Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/
More informationInstallation Manual for Hot Yoga Studio Electric Radiant Heating
105 Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/
More informationcontrol sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals
control sequences Table 47: QST / EST Analog Electronic Control Strategies Control Package Number QST EST FS-A-5000 FSE-A-5000 FS-A-5001 FSE-A-5001 FS-A-5002 FSE-A-5002 FS-A-5003 FSE-A-5003 FS-A-5004 FSE-A-5004
More informationVAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1
Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number
More informationTO DO IF YOU SMELL GAS
Installation and Operation Instructions Document 8001D Installation and Operation Instructions for Mini-Combo II (Models MCT, MCS) esidential Gas-Fired Space/ater Heater NOTE: This manual is to be used
More informationCP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins
P-6 Installation and Operation Instructions 3 Heat / 2 ool Heat Pump with Fossil Fuel option Auto hangeover - ooling Priority or Majority Wins Sequence of Operation: Each zone damper is controlled by its
More informationPerformance Aire offers three VAV comfort solution packages.
The Problem Overheating or overcooling problem areas? As heating and cooling zones grow larger budget constraints cause multiple work spaces to be controlled by a single thermostat. This causes system
More informationINSTALLATION GUIDE. AAN & AEN Series - Manufactured Housing Electric Furnace. 1. Safety Instruction. 2. Inspection ! CAUTION CAUTION `!
INSTALLATION GUIDE AAN & AEN Series - Manufactured Housing Electric Furnace. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction with
More informationDIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications
Installation Guide DIGIU Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications -Zone Controller for the RNC Market Part #DMAN October 004 Zoning Systems That s all we do. INTRODUCTION
More informationRamp It Up VAV Ramps and Controller Possiblities
Head Office Neptronic 400 Lebeau Blvd. Montreal, Quebec, Canada H4N R6 Tel.: (54) -4 Fax: (54) -6 Toll Free: -800-6-08 Ramp It Up VAV Ramps and Controller Possiblities The following article explains the
More informationTZ-3 TotalZone Zone Control Panel
TZ-3 TotalZone Zone Control Panel FEATUES PODUCT DATA APPLICATION The TZ-3 TotalZone Zone Control Panel controls single-stage, multi-stage, conventional or heat pump heat/cool equipment. It controls 2
More informationW859F Economizer Control Packages
Economizer Control Packages 859F Economizer Control Packages are used with any Series 9 Modutrol IV Motor (M9XX) to modulate the outdoor and return air dampers for most economical operation of an economizer
More informationSC-LLC-200 LEAD/LAG CONTROLLER INSTALLATION INSTRUCTIONS
LEAD/LA CONTOLLE INSTALLATION INSTUCTIONS INTODUCTION The from Specified Controls is a versatile, AC powered lead/lag controller offering true dual stage control to balance the operating run time between
More informationInstaller s Guide ACONT200AN11AA 1 Heat (Gas, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 Wire Hookup
11-HD03D1-3 Available in French Canadian (FC) Installer s uide ACONT200AN11AA 1 Heat (as, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 ire Hookup ALL phases of this installation must comply with
More informationONX908PIT-V1-S1-F1/B Modulating Digital Thermostat
ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat Installation and operation instructions The ONX908PIT-V1-S1-F1 modulating digital thermostats are designed to provide Proportional-Integral (PI) modulating
More informationDesign & Installation for. Zonex Systems. System Zone Auto Changeover. System Zone Manual Changeover
Design & Installation for Zonex Systems System 2000 2-20 Zone Auto hangeover System 1000 2-7 Zone Manual hangeover Part #101ASIM ev. September 2003 TABLE OF ONTENTS System 2000 System Operation...1 omponents...1
More informationProduct Instructions. Viega Programmable Heat/Cool Thermostat. Technical data
Programmable Heat/ool Thermostat The programmable heat/cool thermostat is easy to install, easy to wire, and easy to program. It can be used for single stage heating and cooling applications, making it
More informationZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment
ZonexCommander ZonexCommander(Plus) Network All Your HVAC Equipment Centralized DDC Communications for Stand-Alone HVAC and Zoned Systems Installation and Applications Manual Part #ZCMAN Rev. Oct 2014
More informationMB Therma-Fuser Standalone Motorized Disc VAV Diffuser
MB Therma-Fuser Standalone Motorized Disc VAV Diffuser Models: MB-M MB-S MB-D Master with sensor and controller Slave with controller to follow master Drone with controller for 3rd party control Therma-Fuser
More informationT6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control
T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control Application Data sheet T6865 digital thermostats are designed for application of 3-speed fan and modulating valves in fan coil system.
More informationT-32-TS Touchscreen Thermostat. Installation Manual
T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,
More informationI N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.
I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER IOM TA1/TA2 C O N T R O L L E R Table of Contents Table of Contents...2 List of Figures...3 List of Tables...3 Section 1 - General Information...4
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication
Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication Description The TFHB24F3XYZ1 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications.
More informationModel 1750A/ 1770A Dehumidifier Installation Instructions
Model 1750A/ 1770A Dehumidifier Installation Instructions Safety Instructions WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed
More informationSmartZone TM System Manual
SmartZone TM System Manual Rev C3 June 1, 2007 Page 0 of 21 Table of Contents SmartZone TM System Manual Rev C3. April 23, 2007 Introduction..2 o Why Use Residential Zoning?..2 Architectural Challenges...
More informationWiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.
THE EEN Z NE Z EE THE NE N Sequence of Operation: The reen Zone Z-300-HPS is a residential / light commercial zone control system that allows a single HVA unit to have up to three separate zones. Each
More informationRooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422
ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationMBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser
MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser Models: MBS-M MBS-S MBS-D Master with sensor and controller Slave with controller to follow master Drone with controller for 3rd party control Therma-Fuser
More informationMini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater
Installation and Operation Instructions Document 2101B Installation and Operation Instructions for Mini-Combo id Model MCH Induced Draft esidential Gas-Fired Space/Water Heater Note: This document is to
More informationT6984 A,D,E Electronic Floating Control Thermostats
T6984 A,D,E Electronic Floating Control Thermostats FEATURES PRODUCT DATA PI (proportional and integral) control action provides accurate, stable room temperature control. T6984 models are used with Series
More informationTECH SHEET - DO NOT DISCARD PAGE 1
TECH SHEET - DO NOT DISCAD PAGE 1 ANING Electrical Shock Hazard Disconnect power before servicing. eplace all parts and panels before operating. Failure to do so can result in death or electrical shock.
More informationY8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control
Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol FEATUES PODUT DATA Designed to help meet local ventilation codes and standards, including ASHAE 62.2-200 standard, Ventilation and Acceptable
More informationTHERMOSTAT series TM10
MECHANICAL THERMOSTAT series TM10 For central (main) or zoned control of low voltage heating or cooling systems not requiring a thermostat with fan control. Available in 2 and 3 wire (heating or cooling
More informationExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C
ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C DataSheet ev 1.10.403/4.02 November 6, 2012 Operating Sequence Standard Occupied During
More informationCP CP
CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling
More informationSmart Temp. ApolloP/n Installation Manual. Version 1.0
Smart Temp ApolloP/n 44-800 Installation Manual Version 1.0 TABLE OF CONTENTS Introduction...6 Getting started...7 Installing the thermostat...8 Disassembly...8 Thermostat location...8 Mounting the subbase...8,
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor
Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional
More informationT6590 Series FAN-COIL CONTROLLER
T6590 Series FANCOIL CONTROLLER PRODUCT DATA FEATURES APPLICATIONS The T6590 range of digital thermostats is designed to control the valves, fan and auxiliary electric heater within fancoil systems. Modern,
More informationLZP-2 ZONE CONTROL PANEL
2004 Lennox Industries Inc. Dallas, Texas, USA ZONING SYSTEM 504,926M 5/2004 Litho U.S.A. LZP-2 ZONE CONTROL PANEL INSTALLATION INSTRUCTIONS FOR ZONE CONTROL PANELS USED WITH LENNOX HEATING AND COOLING
More informationZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment
ZonexCommander ZonexCommander(Plus) Network All Your HVAC Equipment Centralized DDC Communications for Stand-Alone HVAC and Zoned Systems Installation and Applications Manual Part #ZCMAN Rev. July 2010
More informationINSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?
INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency
More informationINSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.
INSTALLATION MANUAL This manual covers TopTech models: TT-N-721 and T721 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux.
More informationT8400C and T8401C Electronic Thermostats
T8400 and T840 Electronic Thermostats INSTALLATION INSTUTIONS The T8400 and T840 Thermostats provide singlestage, non-programmable temperature control for 4V heating-cooling systems with manual changeover
More informationNetworkable Fan Coil Controller Specification and Installation Instructions
Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat
More informationHealthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.
PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130
More informationEngineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.
VAV Diffusers lease refer to the rice Engineer s HVAC Handbook for more information on VAV Diffusers. Diffuser Types Ceiling Diffusers Conventional air distribution systems typically group several rooms
More informationCUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams
Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available
More informationComfort System T-21-P Touchscreen Thermostat Installation Manual
Comfort System T-21-P Touchscreen Thermostat Installation Manual Version 1.40 INTRODUCTION The Comfort System T-21-P is a feature-rich touchscreen thermostat that can be battery powered or hardwired to
More informationT6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA
T6590 Series FANCOIL CONTROLLER PRODUCT DATA FEATURES APPLICATIONS The T6590 range of digital thermostats is designed to control the valves, fan and auxiliary electric heater within fancoil systems. Modern,
More informationINSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.
INSTALLATION MANUAL This manual covers TopTech models: TT-S-755H Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or
More informationTwo-Position Electric Duplex Room Thermostats
TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features:
More informationInstallation Instructions
FAVXXR6C2100-A01 Vent Damper and Control Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING ATTENTION INSTALLER: This product must be installed by a qualified
More informationSEQUENCE OF OPERATIONS
SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,
More informationWARNING CAUTION 50T INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS. Integrated Furnace Control
50T35-743 Integrated Furnace Control INSTALLATION INSTUCTIONS FAILUE TO EAD AND FOLLO ALL INSTUCTIONS CAEFULLY BEFOE INSTALLIN O OPEATIN THIS CONTOL COULD CAUSE PESONAL INJUY AND/O POPETY DAMAE. DESCIPTION
More informationY8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control
Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol FEATUES PODUT DATA APPLIATION The Y850 Fresh Air Ventilation System, 850 Fresh Air Ventilation ontrol provide fresh air to a home. The
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More informationAutomatic Digital Humidifier Control
Automatic Digital umidifier Control Safety and Installation Instructions EAD COMPLETE INSTALLATION INSTUCTIONS AND TEMPLATE BEFOE STATING. WANING ATTENTION INSTALLE: This product must be installed by a
More informationApplied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat
Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features
More informationT8000C Programmable Thermostat
T8000C Programmable Thermostat APPLICATIN The T8000C Thermostat provides single-stage, programmable temperature control for 24 Vac heating-cooling systems with manual changeover from heat to cool. Heating
More informationZoning System Design Manual
Zoning Made Effortless 70-2321-03 Introduction The Concept of Zoning The basic principle of forced air zoning is to allow one HVAC system to be controlled by multiple thermostats, heating and cooling a
More informationProduct Manual SZ1022/SZ1031/SZ1035/
Product Manual SZ1022/SZ1031/SZ1035/ Conventional Heating & Cooling Thermostats Communicating Thermostats Description The SZ1022, SZ1031, and SZ1035, are microprocessorbased mable thermostats designed
More informationTECH SHEET - DO NOT DISCARD PAGE 1
TECH SHEET - DO NOT DISCAD PAGE 1 ANING Electrical Shock Hazard Disconnect power before servicing. eplace all parts and panels before operating. Failure to do so can result in death or electrical shock.
More informationINSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.
INSTALLATION MANUAL This manual covers TopTech models: TT-N-851 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or
More informationRC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions
RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions DESCRIPTION The RC-90 is a precision digital thermostat designed for 24 VAC single stage heating and
More informationT7984 A,B,C Electronic Modulating Control Thermostats
T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in
More informationINSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.
INSTALLATION MANUAL This manual covers the following models: T725 Thermostat Applications Guide Des cription Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux. or
More informationCLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE
CONSTANT VOLUME LINEAR CEILING DIFFUSER 12 CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL
More informationT8700B,C An Electronic Round Programmable Thermostat
B,C An Electronic ound Programmable Thermostat FEATUES PODUCT DATA APPLICATION C The Electronic ound Programmable Thermostats provide single-stage, programmable temperature control for 24V heating and/or
More informationTECH SHEET - DO NOT DISCARD PAGE 1
TECH SHEET - DO NOT DISCAD PAGE ANING Electrical Shock Hazard Disconnect power before servicing. eplace all parts and panels before operating. Failure to do so can result in death or electrical shock.
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has
More informationExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling
ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling DataSheet ev 1.12.304/4.0 June 14, 2016 Operating Sequence
More informationModel DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions
Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions Safety CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical
More informationPredator Controller Hardware Family
Predator Controller Hardware Family Figure1: Predator Controller Only. Figure 2: Predator VAV Actuator. The LONMARK certified configurable Predator Controller provides direct digital control of a variety
More informationELECTRONIC COMMUNICATING THERMOSTAT
O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-81 Single Stage Heat/Cool Real Time Pricing System Document Number 13I00-2 January, 1997 Copyright 1997 Home Automation, Inc.
More informationModel 8120 and 8126 Safety & Installation Instructions
Ventilation Controller Model 8120 and 8126 Safety & Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING DANGER ATTENTION INSTALLER: To prevent serious injury
More informationEnviroZone-4 & EnviroZone-2 Quick-Start Guide
EnviroZone-4 & EnviroZone-2 Quick-Start Guide This guide is intended to give the installer a brief set of instructions about how to set up the FHP EnviroZone System. For more detailed information about
More informationCommercial Touchscreen Thermostat
55,13M 1/27 Supersedes 12/25 Commercial Touchscreen Thermostat 25 Lennox Industries, Inc. Dallas, Texas, USA APPLICATION Page 1 INSTALLATION INSTRUCTIONS The Lennox Commercial Touchscreen Thermostat provides
More informationUnico Training. Class for R E Michel Salesmen
Class for R E Michel Salesmen Outlet (UPC-56B) Sound Attenuator (UPC-26C) Elbow Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling Modules (MC2430, MC3642,
More informationInstallation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN
Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN April 2005 CNT-SVX07C-EN Tracer ZN521 Zone Controller Installation
More informationSafety and Installation Instructions Model 1700
Dehumidifier Filter Access Humidity Control Inlet Filter Access Outlet Service Access Port Wiring Access Wire Routing Port Drain On/Off Switch Safety and Installation Instructions Model 1700 INSTALLER
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationTEC210x-2 Series Networked Thermostats
Product Bulletin Issue Date February 1, 2005 TEC210x-2 Series Networked Thermostats The TEC210x-2 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationVENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS
VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1070 NON- PROGRAMMABLE 2 OR 4 PIPE SYSTEMS Remote sensor ready 3 speed fan control Self-prompting adjustment Auto 2-pipe changeover when used with ACC-SENFC
More informationT8034C Heating/Cooling Thermostats
T8034C Heating/Cooling Thermostats INSTALLATI INSTUCTIS APPLICATI These T8034C Thermostats control 4 to 30 Vac singlestage heating-cooling systems. An spdt mercury switch makes (H) to on temperature fall
More informationExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet
ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet DataSheet ev 1.2.008/4.1 July 30, 2013 Operating Sequence Standard Occupied During normal occupied operation the display will show
More informationProduct Manual SZ1024/SZ1033. Title Heat Subtitle Pump Thermostats
Product Manual SZ1024/SZ1033 Title Heat Subtitle Pump Thermostats Communicating Thermostats Description The SZ1024 and SZ1033 are microprocessor-based mable thermostats designed for heat pump applications.
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section
More informationETAF Series VDC Fan output LCD Fan Coil Thermostat
ETAF Series 0...10 VDC Fan output LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight 0-10 VDC (2-10 VDC) Fan speed output Retention of temperature
More informationAIR TERMINALS & DUCT HEATERS.
AIR TERMINALS & DUCT HEATERS. TABLE OF CONTENTS. 4 2 CAV AIR TERMINAL UNITS 3 BYPASS AIR TERMINAL UNITS 52 DIGITAL THERMOSTATS FOR AIR TERMINAL UNITS 2 3 VAV AIR TERMINAL UNITS 4 5 SINGLE DUCT PRESSURE
More informationT60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability
T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,
More information5+2 Day. up to HEAT COOL
Digital Thermostat residential THEMOSTAT T1050 5+2 Day POGAMMABLE up to 2-heat & 2-cool HEAT COOL HEAT PUMP Control up to 2 heat & 2 Cool Stages 4 Settings Per Day Self-prompting programming Auto changeover
More informationRC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control
O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS
More informationJob Name Control Systems Description Date
Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In
More informationINSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.
INSTALLATION MANUAL This manual covers the following models: T905 Thermostat Applications uide Description as or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or
More informationEL-TSTAT-8820 Safety & Installation Instructions
EL-TSTAT-8820 Safety & Installation Instructions TABLE OF CONTENTS WI-FI SETUP Wi-Fi Setup 2 INSTALLATION Installation location recommendations 3 Outdoor temperature sensor (included) 3 Remote temperature
More informationInstallation, Safety & Maintenance Manual Model 1750A/1770A
Central Dehumidifier Filter Access Humidity Control Inlet Outlet Service Access Port Filter Access Wiring Access Wire Routing Port Drain On/Off Switch Installation, Safety & Maintenance Manual Model 1750A/1770A
More informationINSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.
INSTALLATION MANUAL This manual covers the following models: T805 Thermostat Applications uide Des cription as or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or
More informationCommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET
CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or
More information