technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

Size: px
Start display at page:

Download "technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air"

Transcription

1 technical data FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air

2 Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice. Zandvoordestraat 300 B Ostend Belgium Internet: EEDE04-/2 02/2004 Prepared in Belgium by Goekint Graphics

3 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB TABLE OF CONTENTS FTKS/FTXS-C/B Features Specifications... 3 Nominal capacity, capacity steps and nominal input Technical specifications 3 Dimensional drawings Piping diagrams Wiring diagrams Sound level... 9 Sound level data Sound pressure spectrum 7 Accessories Standard accessories Optional accessories 8 Control systems Center of gravity Installation For capacity tables, please refer to part II: outdoor units Split - Sky Air Indoor units

4 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB Features + Flat front panel: its stylish appearance fits easily within any interior décor and is more easy to clean. + Lightweight and compact + The movement sensor saves power consumption in unoccupied rooms. + The home leave operation saves energy during absence. + Automatic horizontal and vertical auto-swing ensures uniform air flow and temperature distribution. + 3D-air flow (50,60,7 class only) + Powerful mode can be selected for rapid cooling or heating. + Air purification filter with photocatalytic deodorising function - deodorises the air - powerful decomposes cigarette and pet odours - removes house dust and pollen - deactivates bacteria and viruses + Indoor / outdoor unit silent operation Silent buttons on the remote control lower the operating sound of the indoor and/or outdoor unit by 3dB(A) each. + Night quiet mode automatically reduces the operating sound of the outdoor unit by 3dB(A) at night. multi outdoors in cooling mode only + Up to 4 indoor units can be connected to Multi outdoor unit. All indoor units are individually controllable with remote control and do not need to be installed in the same room. They operate simultaneously within the same cooling or heating mode. + The outdoor unit can easily be mounted on a roof, a terrace or placed against an outside wall. + Outdoor units are fitted with a swing compressor, renowned for its low noise and energy efficiency. + The remote control has a 24 hour timer + The indoor model also has a start/stop button mounted on the front panel + Up to 5 indoor units can be operated from a single centralised control + Purpose designed holder provided for your remote control 2 3 r 0 q 7 x Standard 5 steps Optional z! 2 Split - Sky Air Indoor units FTXS FTKS MKS/MXS (cooling appl. only)

5 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTKS20CVMB FTKS25CVMB FTKS35CVMB NOMINAL INPUT Cooling nominal kw For combination indoor + outdoor units (air cooled): INDOOR UNITS FTKS20CVMB FTKS25CVMB FTKS35CVMB OUTDOOR UNITS - PAIR APPLICATION RKS20CVMB RKS25CVMB RKS35CVMB NOMINAL CAPACITY (2-3) Cooling () min. nom. max. kw NOMINAL INPUT Cooling min. nom. max. kw EER ENERGY LABEL Cooling A A A ANNUAL ENERGY CONSUMPTION Cooling kwh OUTDOOR UNITS - PAIR APPLICATION RKH20CVMB RKH25CVMB RKH35CVMB NOMINAL CAPACITY (2-3) Cooling () min. nom. max. kw NOMINAL INPUT Cooling min. nom. max. kw EER ENERGY LABEL Cooling A A B ANNUAL ENERGY CONSUMPTION Cooling kwh OUTDOOR UNITS - MULTI APPLICATION 2MKS40/3MKS50/4MKS58,75,90B 4MKS58,75,90B For more information, see chapter MKS-B TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTKS25CVMB FTKS25CVMB FTKS35CVMB DIMENSIONS Unit H mm 273 W mm 784 D mm 95 WEIGHT Unit kg 7.5 COLOUR Unit White SOUND LEVEL Sound pressure (cooling) (4) high db(a) low db(a) super low db(a) Sound power (cooling) (5) db(a) FAN Air flow rate (cooling) high m 3 /min low m 3 /min super low m 3 /min Speed steps 5 steps, silent and auto high rpm,340,340,340 medium rpm,090,090,00 low rpm Type Cross flow fan Motor output W HEAT EXCHANGER Type ML fin - J7Hi - XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 2 x.4 2 x 2 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microcomputer control PIPING CONNECTIONS liquid mm J 6.4 gas mm J 9.5 drain mm J 8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter RKS-C/RKH-C Multi application See chapter MKS-B 3D044242B 3D044243B 3D044244B Split - Sky Air Indoor units 3

6 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications 2 NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTKS50BVMB FTKS60BVMB FTKS7BVMB NOMINAL INPUT Cooling nominal kw For combination indoor + outdoor units (air cooled): INDOOR UNITS FTKS50BVMB FTKS60BVMB FTKS7BVMB OUTDOOR UNITS - PAIR APPLICATION RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 NOMINAL CAPACITY (2-3) Cooling () min. nom. max. kw NOMINAL INPUT Cooling min. nom. max. kw EER ENERGY LABEL Cooling B C C ANNUAL ENERGY CONSUMPTION Cooling kwh 830,060,265 OUTDOOR UNITS - MULTI APPLICATION 4MKS58,75,90B 4MKS75,90B 4MKS90B For more information, see chapter MKS-B TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTKS50BVMB FTKS60BVMB FTKS7BVMB DIMENSIONS Unit H mm W mm 795,050 D mm WEIGHT Unit kg 9 2 COLOUR Unit White SOUND LEVEL Sound pressure (cooling) (4) high db(a) low db(a) super low db(a) Sound power (cooling) (5) db(a) FAN Air flow rate (cooling) high m 3 /min low m 3 /min super low m 3 /min Speed steps 5 steps, silent and auto high rpm,340,330,370 medium rpm,80,70,20 low rpm,00,00,040 Type Cross flow fan Motor output W HEAT EXCHANGER Type ML fin - J8Hi - XA tube Rows x stages x fin pitch mm 2 x 6 x.4 2 x 6 x.4 2 x 6 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microcomputer control PIPING CONNECTIONS liquid mm J 6.4 gas mm J 2.7 J 5.9 drain mm J 8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter RKS-B Multi application See chapter MKS-B 3D04078A 3D040782A 3D040783A 4 Split - Sky Air Indoor units

7 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications ELECTRICAL SPECIFICATIONS For indoor units only: FTKS20CVMB FTKS25CVMB FTKS35CVMB CURRENT Nominal running current cooling A Maximum running current cooling A See chapter RKS-C: electrical data 2 For combination indoor units + outdoor units: FTKS20CVMB FTKS25CVMB FTKS35CVMB RKS20CVMB RKS25CVMB RKS35CVMB CURRENT Nominal running current cooling A Maximum running current cooling A Starting current cooling A See chapter RKS-C: electrical data For combination indoor units + outdoor units: FTKS20CVMB FTKS25CVMB FTKS35CVMB RKH20CVMB RKH25CVMB RKH35CVMB CURRENT Nominal running current cooling A Maximum running current cooling A Starting current cooling A See chapter RKH-C: electrical data For combination indoor units + outdoor units: FTKS20CVMB FTKS25CVMB FTKS35CVMB 2MKS40/3MKS50/4MKS58,75,90B CURRENT Nominal running current cooling A Maximum running current cooling A See chapter MKS-B: electrical data Starting current cooling A For indoor units only: FTKS20CVMB FTKS25CVMB FTKS35CVMB POWER SUPPLY VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz Voltage V D044242B 3D044243B 3D044244B NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 3 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 4 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 The Energy Label Directive 2002/3/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. 8 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) Split - Sky Air Indoor units 5

8 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FTKS50BVMB FTKS60BVMB FTKS7BVMB CURRENT Nominal running current cooling A Maximum running current cooling A See chapter RKS-B: electrical data For combination indoor units + outdoor units: FTKS50BVMB FTKS60BVMB FTKS7BVMB RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 CURRENT Nominal running current cooling A Maximum running current cooling A Starting current cooling A See chapter RKS-B: electrical data For combination indoor units + outdoor units: FTKS50BVMB FTKS60BVMB FTKS7BVMB 4MKS58,75,90B 4MKS75,90B 4MKS90B CURRENT Nominal running current cooling A Maximum running current cooling A See chapter MKS-B: electrical data Starting current cooling A For indoor units only: FTKS50BVMB FTKS60BVMB FTKS7BVMB POWER SUPPLY VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz Voltage V D04078A 3D040782A 3D040783A NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 3 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 4 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 The Energy Label Directive 2002/3/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. 8 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) 6 Split - Sky Air Indoor units

9 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTXS20CVMB FTXS25CVMB FTXS35CVMB NOMINAL INPUT Cooling nominal kw Heating nominal kw For combination indoor + outdoor units (air cooled): INDOOR UNITS FTXS20CVMB FTXS25CVMB FTXS35CVMB OUTDOOR UNITS - PAIR APPLICATION RXS20CVMB RXS25CVMB RXS35CVMB NOMINAL CAPACITY (3-4) Cooling () min. nom. max. kw Heating (2) min. nom. max. kw NOMINAL INPUT Cooling min. nom. max. kw Heating min. nom. max. kw EER Cooling COP Heating ENERGY LABEL Cooling A A A Heating A A B ANNUAL ENERGY Cooling kwh CONSUMPTION INDOOR UNITS FTXS20CVMB FTXS25CVMB FTXS35CVMB OUTDOOR UNITS - PAIR APPLICATION RXH20CVMB RXH25CVMB RXH35CVMB NOMINAL CAPACITY (3-4) Cooling () min. nom. max. kw Heating (2) min. nom. max. kw NOMINAL INPUT Cooling min. nom. max. kw Heating min. nom. max. kw EER Cooling COP Heating ENERGY LABEL Cooling A A B Heating B B B ANNUAL ENERGY CONSUMPTION Cooling kwh OUTDOOR UNITS - MULTI APPLICATION 2MXS40/3MXS52/4MXS68/80B For more information, see chapter MXS-B 3D044245B 3D044246B 3D044247B Split - Sky Air Indoor units 7

10 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications 2 NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTXS50BVMB FTXS60BVMB FTXS7BVMB NOMINAL INPUT Cooling nominal kw Heating nominal kw For combination indoor + outdoor units (air cooled): INDOOR UNITS FTXS50BVMB FTXS60BVMB FTXS7BVMB OUTDOOR UNITS - PAIR APPLICATION RXS50BVMB RXS60BVMB RXS7BVMB NOMINAL CAPACITY (3-4) Cooling () min. nom. max. kw Heating (2) min. nom. max. kw NOMINAL INPUT Cooling min. nom. max. kw Heating min. nom. max. kw EER Cooling COP Heating ENERGY LABEL Cooling B C C Heating B C C ANNUAL ENERGY CONSUMPTION Cooling kwh 830,060,265 OUTDOOR UNITS - MULTI APPLICATION 3MXS52/ 4MXS68,80B 4MXS80B 4MXS68,80B For more information, see chapter MXS-B 3D040778A 3D D040780A 8 Split - Sky Air Indoor units

11 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTXS20CVMB FTXS25CVMB FTXS35CVMB DIMENSIONS Unit H mm 273 W mm 784 D mm 95 WEIGHT Unit kg 7.5 COLOUR Unit White SOUND LEVEL Sound pressure high db(a) 38/38 38/38 39/39 (cooling/heating) (5) low db(a) 25/28 25/28 26/29 super low db(a) 22/25 22/25 23/26 Sound power (cooling/heating) (6) high db(a) 56/56 56/56 57/57 FAN Air flow rate (cooling/heating) high m 3 /min 7.7/ / /8. low m 3 /min 4.2/ / /5.3 super low m 3 /min 3.6/ / /4.6 Speed (cooling/heating) steps 5 steps, silent and auto high rpm,340/,300,340/,300,340/,340 medium rpm,090/,30,090/,30,00/,50 low rpm 840/ / /960 Type Cross flow fan Motor output W HEAT EXCHANGER Type ML fin - J7Hi - XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 2 x.4 2 x 2 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microcomputer control PIPING CONNECTIONS liquid mm φ6.4 gas mm φ9.5 drain mm φ8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes 2 For outdoor units Pair application See chapter RXS-C/RXH-C Multi application See chapter MXS-B 3D044245B 3D044246B 3D044247B Split - Sky Air Indoor units 9

12 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications 2 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTXS50BVMB FTXS60BVMB FTXS7BVMB DIMENSIONS Unit H mm W mm 795,050 D mm WEIGHT Unit kg 9 2 COLOUR Unit White SOUND LEVEL Sound pressure high db(a) 44/42 45/44 46/46 (cooling/heating) (5) low db(a) 35/33 36/35 37/37 super low db(a) 32/30 33/32 34/34 Sound power (cooling/heating) (6) high db(a) 63/60 63/62 63/63 FAN Air flow rate (cooling/heating) high m 3 /min.4/ / /8.5 low m 3 /min 8.0/8.9.4/2.7.6/3.5 super low m 3 /min 7./ /.4 0.6/2. Speed (cooling/heating) steps 5 steps, silent and auto high rpm,340/,370,330/,360,370/,440 medium rpm,80/,200,70/,200,20/,270 low rpm,00/,030,00/,040,040/,00 Type Cross flow fan Motor output W HEAT EXCHANGER Type ML fin - J8Hi - XA tube Rows x stages x fin pitch mm 2 x 6 x.4 2 x 6 x.4 2 x 6 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microcomputer control PIPING CONNECTIONS liquid mm φ6.4 gas mm φ2.7 φ5.9 drain mm φ8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter RXS-B Multi application See chapter MXS-B 3D040778A 3D D040780A 0 Split - Sky Air Indoor units

13 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications ELECTRICAL SPECIFICATIONS For indoor units only: FTXS20CVMB FTXS25CVMB FTXS35CVMB CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A See chapter RXS-C: electrical data 2 For combination indoor units + outdoor units: FTXS20CVMB FTXS25CVMB FTXS35CVMB RXS20CVMB RXS25CVMB RXS35CVMB CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A Starting current cooling A See chapter RXS-C: electrical data heating A For combination indoor units + outdoor units: FTXS20CVMB FTXS25CVMB FTXS35CVMB RXH20CVMB RXH25CVMB RXH35CVMB CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A Starting current cooling A See chapter RXH-C: electrical data heating A For combination indoor units + outdoor units: FTXS20CVMB FTXS25CVMB FTXS35CVMB 2MXS40/3MXS52/4MXS68,80B CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A See chapter MXS-B: electrical data Starting current cooling A heating A For indoor units only: FTXS20CVMB FTXS25CVMB FTXS35CVMB POWER SUPPLY VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz Voltage V D044245B 3D044246B 3D044247B NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature 20 CDB * outdoor temperature 7 CDB/6 CWB * refrigerant piping length 7.5m (horizontal) * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 5 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 6 The sound power level is an absolute value indicating the power which a sound source generates. 7 Energy label: scale from A (most efficient) to G (less efficient). 8 The Energy Label Directive 2002/3/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. 9 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) Split - Sky Air Indoor units

14 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FTXS50BVMB FTXS60BVMB FTXS7BVMB CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A See chapter RXS-B: electrical data For combination indoor units + outdoor units: FTXS50BVMB FTXS60BVMB FTXS7BVMB RXS50BVMB RXS60BVMB RXS7BVMB CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A Starting current cooling A See chapter RXS-B: electrical data heating A For combination indoor units + outdoor units: FTXS50BVMB FTXS60BVMB FTXS7BVMB 3MXS52/ 4MXS68,80B 4MXS68,80B 4MXS80B CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A See chapter MXS-B: electrical data Starting current cooling A heating A For indoor units only: FTXS50BVMB FTXS60BVMB FTXS7BVMB POWER SUPPLY VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz Voltage V D040778A 3D D040780A NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature 20 CDB * outdoor temperature 7 CDB/6 CWB * refrigerant piping length 7.5m (horizontal) * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 5 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 6 The sound power level is an absolute value indicating the power which a sound source generates. 7 Energy label: scale from A (most efficient) to G (less efficient). 8 The Energy Label Directive 2002/3/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. 9 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) 2 Split - Sky Air Indoor units

15 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 3 Dimensional drawings FTK/XS C unit (mm) 3 The mark (Y) shows piping direction Left Rear Right Air flow (indoor) required space (for performance and maintenance) (including installation plate) (space for performance) Home leave lamp (space for maintenance) Name plate (space for maintenance) Bottom Front grille fixing screws (Inside) Flaps Signal transmitter Signal receiver Room temp. thermistor Intelligent movement sensor Timer lamp Operation lamp Indoor unit ON/OFF switch Terminal block with earth terminal Gas pipe 9.5Cut (The length of pipe outside the unit: about 300) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) (The hose length on the outside of the unit is approx. 40) Blade angle Up/down (automatic) Cooling, dry Heating FTXS--: (ARC433A) FTKS--: (ARC433A2) Infrared remote control Right/left (manual) Wall hole for embedded piping J 65 hole Standard locations of wall holes Wall hole J 65 hole 3D FTK/XS50B Air flow (indoor) required space (for performance and maintenance) unit (mm) The mark (Y) shows piping direction Left Rear Rear Right (including installation plate) 50 MIN 50 MIN (space for maintenance) Required space 30 MIN (space for performance) (space for maintenance) Name plate Bottom Flaps Front grille fixing screws (Inside) Signal transmitter Home leave lamp Operation lamp Signal receiver Indoor unit ON/OFF switch Intelligent movement sensor Room temp. thermistor Timer lamp Blade angles Terminal block with earth terminal (Inside) Gas pipe 2.7Cut (The length of pipe outside the unit: about 340) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) (The hose length on the outside of the unit is approx. 440) Horizontal blade (Automatic) Cooling, dry Heating (FTX -- only) Dry Infrared remote control FTX---: (ARC433A2) FTK---: (ARC433A22) Vertical blade (Automatic) Wall hole for embedded piping J 65 hole Standard locations of wall holes Wall hole J 65 hole 3D04007 Split - Sky Air Indoor units 3

16 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 3 Dimensional drawings 3 FTK/XS60-7B Air flow (indoor) required space (for performance and maintenance) unit (mm) The mark (Y) shows piping direction Left Rear Rear Right (space for maintenance) (including installation plate) 50 MIN 50 MIN Required space 30 MIN (space for performance) (space for maintenance) Operation lamp Signal receiver Indoor unit ON/OFF switch Room temp. thermistor Name plate Terminal block with earth terminal Bottom Flaps Front grille fixing screws (Inside) Intelligent movement sensor Timer lamp Home leave lamp A FTX(K)S FTX(K)S60-- FTX(K)S7-- B 2.7 Gas pipe J B Cut (The length of pipe outside the unit: about 340) Liquid pipe J A Cut (The length of pipe outside the unit: about 390) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) (The hose length on the outside of the unit is approx. 440) Signal transmitter Horizontal blade (Automatic) Cooling Blade angle Heating (FTX -- only) Dry Vertical blade (Automatic) Infrared remote control Wall hole for embedded piping J 80 hole Wall hole J 80 hole FTX---: (ARC433A233) FTK---: (ARC433A22) Standard locations of wall holes 3D040073A 4 Split - Sky Air Indoor units

17 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 4 Piping diagrams FTK/XS C Indoor unit 4 Heat exchanger Thermistor on heat exchanger Field piping Cross flow fan Fan motor Field piping Refrigerant flow Cooling Heating 4D033698B FTK/XS50-60B Indoor unit Heat exchanger Thermistor on heat exchanger Field piping Cross flow fan Field piping Fan motor Refrigerant flow Cooling Heating 4D04008 Split - Sky Air Indoor units 5

18 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 4 Piping diagrams 4 FTK/XS7B Indoor unit Heat exchanger Thermistor on heat exchanger Field piping Cross flow fan Field piping Fan motor Refrigerant flow Cooling Heating 4D Split - Sky Air Indoor units

19 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 5 Wiring diagrams FTK/XS C 5 Intelligent movement sensor (Terminal for centralised control) Transmission circuit g Field wiring Outdoor CAUTION Signal receiver Note that operation will restart automatically if the main power supply is turned off and then back on again. Infrared remote control Indoor R C70 FU HP H3P MF MS PCB PCB3 RT, R2T S S36 SW XM : Protective earth : Running capacitor : Fuse : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D033599C FTK/XS50B g Field wiring Rectifier Outdoor Transmission circuit CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Intelligent movement sensor Infrared remote control Signal receiver Indoor R FG FU H H3 HP H3P MF MS, M2S PCB PCB5 RT, R2T S S38 SW XM : Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D038065A Split - Sky Air Indoor units 7

20 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 5 Wiring diagrams 5 FTK/XS60-7B g Field wiring Rectifier Outdoor Transmission circuit CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Intelligent movement sensor Infrared remote control Signal receiver Indoor R FG FU H H3 HP H3P MF MS, M2S PCB PCB5 RT, R2T S S38 SW XM : Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D038530B 8 Split - Sky Air Indoor units

21 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 6 Sound level 6- Sound level data Cooling only Sound pressure level Model 230V, 50Hz Sound power level Cooling Measuring location (Cooling) H L SL FTKS20C Location of microphone 56 FTKS25C FTKS35C FTKS50B FTKS60B FTKS7B Heat pump Sound pressure level Model 230V, 50Hz Sound power level Cooling/Heating Measuring location (Cooling/Heating) H L SL FTXS20C 38/38 25/28 22/25 Location of microphone 56/56 FTXS25C 38/38 25/28 22/25 56/56 FTXS35C 39/39 26/29 23/26 57/57 FTXS50B 44/42 35/33 32/30 63/60 FTXS60B 45/44 36/35 33/32 63/62 FTXS7B 46/46 37/37 34/34 63/ Sound pressure spectrum Cooling only FTKS20-25C FTKS35C Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D035255B Octave band center frequency (Hz) 4D035256B Octave band center frequency (Hz) Split - Sky Air Indoor units 9

22 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 6 Sound level Sound pressure spectrum FTKS50B FTKS60B Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D Octave band center frequency (Hz) 4D Octave band center frequency (Hz) FTKS7B Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise 4D Octave band center frequency (Hz) NOTE Operation noise differs with operation and ambient conditions. Legend 50/60Hz / V(H) 50/60Hz / V(L) 20 Split - Sky Air Indoor units

23 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 6 Sound level 6-2 Sound pressure spectrum Heat pump FTXS20-25C (Cooling) FTXS20-25C (Heating) Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D035240B Octave band center frequency (Hz) 3D035240B Octave band center frequency (Hz) FTXS35C (Cooling) FTXS35C (Heating) Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D03524B Octave band center frequency (Hz) 3D03524B Octave band center frequency (Hz) NOTE Operation noise differs with operation and ambient conditions. Legend 50/60Hz / V(H) 50/60Hz / V(L) Split - Sky Air Indoor units 2

24 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 6 Sound level Sound pressure spectrum FTXS50B (Cooling) FTXS50B (Heating) Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D Octave band center frequency (Hz) 3D Octave band center frequency (Hz) FTXS60B (Cooling) FTXS60B (Heating) Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D Octave band center frequency (Hz) 3D Octave band center frequency (Hz) NOTE Operation noise differs with operation and ambient conditions. Legend 50/60Hz / V(H) 50/60Hz / V(L) 22 Split - Sky Air Indoor units

25 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 6 Sound level 6-2 Sound pressure spectrum FTXS7B (Cooling) FTXS7B (Heating) Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D04030 Octave band center frequency (Hz) 3D04030 Octave band center frequency (Hz) NOTE Operation noise differs with operation and ambient conditions. Legend 50/60Hz / V(H) 50/60Hz / V(L) Split - Sky Air Indoor units 23

26 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 7 Accessories Standard accessories FTK/XS C ja Mounting plate je Remote control holder jk Operation manual jb Air purification filter with photocatalytic deodorising function 2 jg AAA dry-cell batteries 2 jl Installation manual jd Infrared remote control jh Indoor unit fixing screws M4x2L 2 FTK/XS B ja Mounting plate je Remote control holder jk Operation manual 2 jb Air purification filter with photocatalytic deodorising function 2 jg AAA dry-cell batteries jl Installation manual jd Infrared remote control jh Indoor unit fixing screws M4x2L Optional accessories FTK/XS-C/B Option name Wiring adapter for time clock / remote control () Normal open contact KRP43AS Normal open pulse contact KRP43AS Centralised control board up to 5 rooms (2) KRC72 Central remote control DCS302B5 Unified ON/OFF control DCS30B5 Schedule timer DST30B5 Interface adapter (3) KRP928A2S Air purification filter with photocatalytic deodorising function (with frame) KAF98A43 Air purification filter with photocatalytic deodorising function (without frame) KAF98A44 Anti-theft protection for remote control KKF97A4 () Wiring adapter is also required for each indoor unit. (2) Wiring adapter supplied by Daikin. Time clock and other devices: field supply. (3) Interface adapter for room air conditioners (DIII-NET) 24 Split - Sky Air Indoor units

27 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 8 Control systems 8- Infrared remote control FTK/XS C 8 8- <ARC433A, A2> Signal transmitter: It sends signals to the indoor unit. 2 Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) 3 HOME LEAVE button: for HOME LEAVE operation 4 POWERFUL button: for POWERFUL operation 5 TEMPERATURE adjustment buttons: It changes the temperature setting 6 ON/OFF button: Press this button once to start operation. Press once again to stop it. 7 MODE selector button: It selects the operation mode (Auto, /DryI / Cool u / Heat w / Fan B) 8 OUTDOOR UNIT SILENT button: SILENT operation 9 FAN setting button: It selects the air flow rate setting. 0 SWING button SENSOR button: for INTELLIGENT EYE Operation 2 ON TIMER button 3 OFF TIMER button 4 TIMER setting button: It changes the time setting 5 TIMER CANCEL button: It cancels the timer setting. 6 CLOCK button Split - Sky Air Indoor units 25

28 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 8 Control systems Infrared remote control FTK/XS B <ARC433A2, A22> Signal transmitter: It sends signals to the indoor unit. 2 Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) 3 HOME LEAVE button: for HOME LEAVE operation 4 POWERFUL button: for POWERFUL operation 5 TEMPERATURE adjustment buttons: It changes the temperature setting 6 ON/OFF button: Press this button once to start operation. Press once again to stop it. 7 MODE selector button: It selects the operation mode (Auto, /DryI / Cool u / Heat w / Fan B) 8 OUTDOOR UNIT SILENT button: SILENT operation 9 FAN setting button: It selects the air flow rate setting. 0 SENSOR button: for INTELLIGENT EYE Operation SWING button Flap (horizontal blade) 2 SWING button Louver (Vertical blades) 3 ON TIMER button 4 OFF TIMER button 5 TIMER setting button: It changes the time setting 6 TIMER CANCEL button: It cancels the timer setting. 7 CLOCK button 26 Split - Sky Air Indoor units

29 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 9 Center of gravity FTK/XS C 9 4D020686H FTK/XS50B 4D0403 FTK/XS60-7B 4D04033 Split - Sky Air Indoor units 27

30 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 0 Installation 0 FTK/XS C Indoor unit installation drawings ja Mounting plate How to attach the indoor unit. Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front panel. How to remove the indoor unit. Push up the marked area (at the lower part of the front panel) to release the claws. If it is difficult to release, remove the front panel. Front panel Bottom frame ja Mounting plate Clip Mark (rear side) The mounting plate should be installed on a wall which can support the weight of the indoor unit. 30mm or more from ceiling Caulk pipe hole gap with putty. Front grille 50 mm or more from walls (on both side) Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe s cut line. Air filters Appearance of the indoor unit may differ from some models. Service lid This service lid is an open/close type. jb Air purification filter with photocatalytic deodorising function Tabs (upper 3 locations) + Remove the screws on the service lid. + Slide the service lid leftward. + Rotate the service lid upward. Tabs (lower 2 locations) Insert the upper side of the jb Air purification filter with photocatalytic deodorising function into the tabs (upper 3 locations), push the lower side of the filters up a little and into the tabs (lower 2 locations). Before screwing the remote control holder to the wall, make sure that control signals are properly received by indoor unit. jd Infrared remote control je Remote control holder 28 Split - Sky Air Indoor units

31 Wall Mounted, Inverter Controlled Unit R-40A FTK/XS20,25,35CVMB FTK/XS50,60,7BVMB 0 Installation FTK/XS B Indoor unit installation drawings 0 ja Mounting plate The figure shows a 50 class unit. (See Indoor Unit Installation. Installing the mounting plate for details regarding 60 and 7 class units.) The mounting plate should be installed on a wall which can support the weight of the indoor unit. 30mm or more from ceiling Caulk pipe hole gap with putty. Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe s cut line. Front grille 50 mm or more from walls (on both side) Wrap the installation pipe with the finishing tape from bottom to top Air filters Only for 60 and 70 class units. Intelligent movement sensor jb Air purifying filter with photocatalytic deodorizing function. 50 class Tabs (upper 3 locations) Service lid Opening service lid Service lid is opening/closing type. Opening method ) Remove the service lid screws. 2) Lift the service lid upward. Tabs (lower 2 locations) 60, 7 class Tabs (upper 3 locations) Tabs (lower 3 locations) Insert the upper side of the jb Air purification filter with photocatalytic deodorising function into the tabs (upper 3 locations), push the lower side of the filters up a little and into the tabs (lower 2 locations) (lower 3 locations). Movement sensor Caution ) Do not hit or violently push the movement sensor. This can lead to damage and malfunction. 2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor s detection area. Split - Sky Air Indoor units 29

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air technical data FT(Y)S-B Wall Mounted Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data FTXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

Air Conditioners. Technical Data FTXS-G

Air Conditioners. Technical Data FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE

More information

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air Indoor Units R-40A FTXS-G2VB

More information

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air technical data FVXS-FV1B R-410A air conditioning systems Split Sky Air Indoor Units R-410A FVXS-FV1B TABLE OF CONTENTS FVXS-FV1B 1 Features.............................................................

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................

More information

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air technical data FHYP-B Ceiling Suspended Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and

More information

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air technical data FHYKP-B Ceiling Mounted Corner Cassette air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

w w w. d a i k i n. e u ATXS-E

w w w. d a i k i n. e u ATXS-E Daikin air conditioners for your home WALL MOUNTED UNIT ATXS-E w w w. d a i k i n. e u Daikin s stylishly elegant wall mounted Siesta unit will grace the dining, living or bedroom of any home. Siesta will

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WALL MOUNTE D UNIT w w w. d a i k i n. e u FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WLL MOUNTED UNIT www.daikineurope.com FTXG-C The UX1 has already won the Good Design ward 2003 for its modern design. This stylish wall mounted unit is available in

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WALL MOUNTED UN IT www.daikineurope.com FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series stylish

More information

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air technical data FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps.   FTXS-G Full range A class energy label Air conditioners, heating & cooling for your home WALL MOUNTED UNIT air to air heat pumps www.daikin.eu FTXS-G FOR EVERY HOME, FOR EVERY ROOM unique features Full range

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3 Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-J3 TALE OF CONTENTS FTX-J3 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9) Air Conditioning Technical Data Flexi type unit EEDEN14-100 FLXS-B(9) Indoor Unit FLXS-B(9) TABLE OF CONTENTS FLXS-B(9) 1 Features............................................................. 2 2 Specifications.......................................................

More information

for your home FLXS-B Flexi type unit air to air heat pumps

for your home FLXS-B Flexi type unit   air to air heat pumps Air conditioners, HEATING & COOLING for your home Flexi type unit air to air heat pumps www.daikin.eu FLXS-B TOP CLASS, MADE FOR A LONG FUTURE The importance of well-being and pleasure is increasing in

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

BENEFIT FROM LOWER FUEL COSTS.

BENEFIT FROM LOWER FUEL COSTS. TODAY, MORE AND MORE PEOPLE ARE MAKING A VERY CONSCIOUS CHOICE TO ENJOY THE COMFORT OF AIR CONDITIONING IN THEIR HOME. IT IS WIDELY RECOGNISED THAT BALANCED AIR CONDITIONING HAS A TANGIBLE EFFECT ON THE

More information

for your home FTXS-G WALL MOUNTED UNIT

for your home FTXS-G WALL MOUNTED UNIT Air conditioners for your home WALL MOUNTED UNIT www.daikin.eu FTXS-G BUILT-IN INTELLIGENCE Pair or Multi Depending on the type of climate you want, you can choose between two models: cooling and heating

More information

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED

More information

AIR CONDITIONERS, HEATING & COOLING for your home

AIR CONDITIONERS, HEATING & COOLING for your home AIR CONDITIONERS, HEATING & COOLING for your home SLIM CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDXS-E FDXS-C COMFORTABLE AIR, THE WHOLE YEAR THROUGH A comfortable living space provides

More information

for your home FTYN-GX FT(Y)N-F

for your home   FTYN-GX FT(Y)N-F Air conditioners for your home W A L L M O U N T E D U N I T www.daikin.eu FTYN-GX FT(Y)N-F FOR EVERY HOME, FOR EVERY ROOM EVERY DAY, MORE AND MORE PEOPLE ARE MAKING A CONSCIOUS EFFORT TO RAISE THEIR QUALITY

More information

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Cooling only INDOOR UNITS FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Capacity cooling min~nom~max kw 1.3~2.0~2.8 1.3~2.5~3.2 1.4~3.5~4.0 1.7~4.2~5.0 1.7~5.0~5.3 1.7~6.0~6.7 2.3~7.1~8.5 Power

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 CTXS-K Indoor Unit Wall mounted unit CTXS-K TABLE OF CONTENTS CTXS-K Features.............................................................

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r u n i t - m u l t i m o d e l E E D E N 2-0 0 MXS-K TABLE OF CONTENTS MXS-K Features............................................................. 2 2 Specifications.......................................................

More information

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling for shops,restaurants and offices Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing

More information

Air conditioners, heating & cooling for the retailmarket and offices

Air conditioners, heating & cooling for the retailmarket and offices Air conditioners, heating & cooling for the retailmarket and offices floor standing unit air to air heat pumps www.daikin.eu FVQ-B MAXIMUM RELIABILITY, MINIMUM ENERGY USE Advanced climate systems in modern

More information

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data EEDEN RXS-F8 Air Conditioning Technical Data EEDEN15-100 RXS-F8 Outdoor Unit RXS-F8 TABLE OF CONTENTS RXS-F8 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems Indoor Units FBQ-C7VEB

technical data air conditioning systems Indoor Units FBQ-C7VEB technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................

More information

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI PART 2 - URURU MULTI MULTI SYSTEM The Daikin Ururu Multi heat pump system is unique in its ability to supply comfort heating, cooling humidification and fresh air ventilation. Designed primarily for two

More information

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air conditioners, heating & cooling. for large spaces. air to air heat pumps.   FDQ-B Air conditioners, heating & cooling for large spaces CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDQ-B THE MOST ADVANCED CLIMATE CONTROL FOR LARGE SPACES The quality air conditoning of Daikin

More information

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN AZQS-BV1 Air Conditioning Technical Data EEDEN14-131 AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW Air Conditioning Technical Data Wall mounted unit EEDEN2-00 FTXG-JW Indoor Unit Wall mounted unit FTXG-JW TABLE OF CONTENTS FTXG-JW Features.............................................................

More information

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E Air Conditioning Technical Data Multi model application EEDEN1-100 MXS-E TABLE OF CONTENTS MXS-E 1 Features............................................................. 2 2 Specifications.......................................................

More information

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal FTXB20-35C Rear side 770 Right side Standard location of holes in the wall 16 770 549 101 172 6 Left side Front panel fixing screws Including mounting plate 216 198 General Rating Nameplate 41.3 54.5 Hole

More information

Air Conditioners. Technical Data FBQ-C

Air Conditioners. Technical Data FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor

More information

EDUS Heat Pump - D-Series

EDUS Heat Pump - D-Series EDUS 04-740 - Heat Pump - D-Series Split-System Room Air Conditioners D-Series The Single Split Duct-Free System Heat Pump FTXS09DVJU FTXS12DVJU FTXS15DVJU FTXS18DVJU FTXS24DVJU RX09FVJU RX12FVJU RX15FVJU

More information

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

Ceiling Suspended Unit

Ceiling Suspended Unit Ceiling Suspended Unit FHQ-B / RZQ-D(BW1) Wired remote control (standard) Wireless remote control (optional) Ceiling suspended units are the ideal solution for rooms without false ceilings. These indoor

More information

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems Indoor Units FCQ-C8VEB technical data Indoor Units FCQ-C8VEB air conditioning systems technical data Indoor Units FCQ-C8VEB air conditioning systems TABLE OF CONTENTS FCQ-C8VEB! 1 Features.............................................................

More information

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K Designed colder climates for AIR TO AIR HEAT PUMPS FTXS-20-25K FTXS35-42-50K Optimised heating solutions down to -25 C outdoor temperatures Prestigious design Prevents winter freezing in summer homes Whisper

More information

Service Manual. Inverter Pair. Floor / Ceiling Suspended Dual Type B-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Service Manual. Inverter Pair. Floor / Ceiling Suspended Dual Type B-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Floor / Ceiling Suspended Dual Type B-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair B-Series Cooling Only Indoor Unit Outdoor

More information

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air technical data RMXS-E7V3B1 Super multi plus air conditioning systems Split Sky Air Outdoor Units R-410A RMXS-E7V3B1 TABLE OF CONTENTS RMXS-E7V3B1 1 Features.............................................................

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-C TABLE OF CONTENTS FDQ-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

2. Pictographs 2.1 Basic Operation

2. Pictographs 2.1 Basic Operation Pictographs 2. Pictographs 2.1 Basic Operation ON / OFF button Operation starts and stops every time you press the button. MODE selector button Operation mode changes every time you press the button. H/P

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Wall mounted unit SEER and SCOP up to A ++ Discreet, modern design Whisper quiet in operation The right indoor for the right room www.daikin.eu FTXS20-25K/CTXS15-35K

More information

Daikin air conditioners for shops, restaurant and offices

Daikin air conditioners for shops, restaurant and offices Daikin air conditioners for shops, restaurant and offices ROUNDFLOW CEILING MOUNTED CASSETTE w w w. d a i k i n. e u FCQH-C The new Daikin Sky Air Roundflow Cassette: Daikin has renewed its Sky Air ceiling

More information

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Remote control infrared ARC433B76 ARC433A8 ARC433B69 Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-

More information

EPCE2004-2B. General. General Catalogue Catalogue. Air Conditioning Systems

EPCE2004-2B. General. General Catalogue Catalogue. Air Conditioning Systems EPCE2004-2B General Catalogue 2004 General Catalogue Air Conditioning Systems Foreword In 1972, Daikin Industries Ltd, established its European headquarters in Ostend, Belgium in answer to the rapidly

More information

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B

More information

air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS

air conditioners for your home, shops, restaurants, offices, small hotels   MULTI MODEL APPLICATIONS air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture

More information

Daikin air conditioners for your home, shops, restaurants and offices

Daikin air conditioners for your home, shops, restaurants and offices Daikin air conditioners for your home, shops, restaurants and offices CONCEALED CE ILING UN IT www.daikineurope.com FDEQ-B7 Concealed ceiling units are built into the false ceiling, leaving only the suction

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

TABLE OF CONTENTS RMXS-E8V1B

TABLE OF CONTENTS RMXS-E8V1B Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................

More information

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type

More information

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFAA2VEB > FFAA2VEB TABLE OF CONTENTS FFA-A 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................

More information

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices EPLE03-17 -WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices NEW FCQ-B indoor unit FCQ35/50/60B7 wired reote control (optional) central reote control (optional)

More information

for the retail market, hotels, restaurants and offices

for the retail market, hotels, restaurants and offices Air conditioners, HEATING & COOLING for the retail market, hotels, restaurants and offices INVERTER DRIVEN CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FBQ-C INtelligent unit, neatly concealed

More information

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air technical data FH(Y)B-FK7 Concealed Ceiling Unit air conditioning systems Split Sky ir Split - Sky ir ISO14001 assures an effective environmental management system in order to help protect human health

More information

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type G-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type G-Series Cooling Only Indoor Unit FTXS20G2V1B

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data F l o o r s t a n d i n g u n i t E E D E N 2-0 0 FVQ-C Indoor Unit Floor standing unit FVQ-C TABLE OF CONTENTS FVQ-C Features.............................................................

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Wall mounted unit SEER up to A++ Discreet, modern design Whisper quiet in operation The right indoor for the right room Heat pump system www.daikin.eu FTXS-20-25K/CTXS-15-35K

More information

EPCE General. Catalogue. Air Conditioning Systems

EPCE General. Catalogue. Air Conditioning Systems EPCE2004-2 General Catalogue Air Conditioning Systems Foreword In 1972, Daikin Industries Ltd, established its European headquarters in Ostend, Belgium in answer to the rapidly growing European demand

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

SiUS041638E. Service Manual. Inverter Pair Wall Mounted Type FTX-N Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041638E. Service Manual. Inverter Pair Wall Mounted Type FTX-N Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Cooling Only Indoor Unit

More information

EEDEN technical data EKRTR. Altherma. Altherma

EEDEN technical data EKRTR. Altherma. Altherma EEDEN08-720 technical data EKRTR Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 4 FTXN-L Indoor Unit Wall mounted unit FTXN-L TABLE OF CONTENTS FTXN-L Features.............................................................

More information

for small rooms in multi application

for small rooms in multi application Air conditioners, heating & cooling for small rooms in multi application concealed ceiling unit air to air heat pumps www.daikin.eu FDbq-b HOSPITALITY STARTS WITH A STABLE AND DRAUGHT-FREE INDOOR CLIMATE

More information

TECENICAL DATA. Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I. Wall mounted Type. DC Inverter E-Series

TECENICAL DATA. Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I. Wall mounted Type. DC Inverter E-Series TECENICAL DATA Order No.AC0902T003V0 Wall mounted Type DC Inverter E-Series Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I 9K 12K 18K 24K 09K 12K 18K WARNING

More information

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type H-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type H-Series Cooling Only Indoor Unit FTXS30HVJU

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling 4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e Energy label:» Up to class A Heat pump system Inverter technology Fits precisely» in standard modules» of

More information

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1 Air Conditioning Technical Data EEDEN14-100 RZQG-L8/7V1 Outdoor Unit RZQG-L8/7V1 TABLE OF CONTENTS RZQG-L8/7V1 1 Features............................................................. 2 2 Specifications.......................................................

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

Air Conditioners. Technical Data RZQG-L

Air Conditioners. Technical Data RZQG-L Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t

More information

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C Service Manual Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA0AUVEB Indoor Unit FAA-A TABLE OF CONTENTS FAA-A 1 Features............................................................. 2 2 Specifications.......................................................

More information

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S air conditioners for your home, shops, restaurants, offices, small hotels M U L T I M O D E L A P P L I C A T I O N S ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in

More information

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F Air Conditioning Technical Data Concealed ceiling unit EEDEN16-100 FDXM-F Indoor Unit FDXM-F TABLE OF CONTENTS FDXM-F 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioners. Technical Data FTY-H

Air Conditioners. Technical Data FTY-H Air Conditioners Technical Data W a l l M o u n t e d U n i t E E D E N 1 0-1 1 0 FTY-H Air Conditioners Technical Data W a l l M o u n t e d U n i t E E D E N 1 0-1 1 0 FTY-H Indoor Unit Wall mounted

More information

Air Conditioning Technical Data RZASG-MV1

Air Conditioning Technical Data RZASG-MV1 Air Conditioning Technical Data RZASG-MV1 Outdoor Unit RZASG-MV1 TABLE OF CONTENTS RZASG-MV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces The best of two worlds united Heating & Cooling > heating & cooling in one Quiet and discrete, Nexura offers you the best in heating and cooling, in

More information

Air Conditioning Technical Data RZAG-MV1

Air Conditioning Technical Data RZAG-MV1 Air Conditioning Technical Data RZAG-MV1 TABLE OF CONTENTS RZAG-MV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1 Air Conditioning Technical Data EEDEN-00 RZQSG-L(/8)V Outdoor Unit RZQSG-L(/8)V TABLE OF CONTENTS RZQSG-L(/8)V Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-B Indoor Unit FDQ-B TABLE OF CONTENTS FDQ-B 1 Features.............................................................

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling Ceiling suspended unit Energy label:» Up to class A Seasonal efficiency, optimized for all seasons Heat pump system Installation possible in new and existing buildings

More information

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1 Air Conditioning Technical Data EEDEN3-00 RZQSG-L(8)Y Outdoor Unit RZQSG-L(8)Y TABLE OF CONTENTS RZQSG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

INSTALLATION MANUAL. R-410A Split Series. Models. Installation manual R-410A Split series. Installationsanleitung Split-Baureihe R-410A

INSTALLATION MANUAL. R-410A Split Series. Models. Installation manual R-410A Split series. Installationsanleitung Split-Baureihe R-410A INSTALLATION MANUAL R-410A Split Series Installation manual R-410A Split series English FTXS, FTKS, FTX,FTK, series. Installationsanleitung Split-Baureihe R-410A Manuel d installation Série split R-410A

More information