HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

Size: px
Start display at page:

Download "HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation"

Transcription

1 Product Data 38YCA (60 Hz) 38YCN Heat Pump HEATING & COOLING 38YCA s 018 thru YCN s 024 thru 048 The 38YCA and 38YCN Outdoor s of Split- Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER up to 10.5 and HSPF up to 7.5, these heat pump systems provide economy of operation through energy conservation when used with components designated by manufacturer. They recover heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, remove indoor heat and excess humidity during the cooling season. All models are listed with UL, c-ul, CEC, and ARI. FEATURES/BENEFITS Electrical Range All units are offered in single phase v. The 38YCA 030 through 060 models are offered in 208/230v 3 phase and 38YCA 036 through 060 are offered in 460v 3 phase. Range The 38YCA is available in 7 nominal sizes from 018 through 060 to meet the needs for residential and light commercial applications. The 38YCN is available in 5 nominal sizes from 024 through 048 to meet the needs of the manufactured housing market. Compressor Designed specifically for heat pump duty, with energy efficiency during heating and cooling operation. Each compressor is hermetically sealed against contamination to assure long life and dependable performance, internally sprung (units with reciprocating compressor) and externally mounted on rubber isolators for quiet operation. Continuous compressor operation is approved down to 30 F ( 34.4 C) in the heating mode, and down to 55 F (12.8 C) in the cooling mode. (See heating and cooling performance tables.) For compressor usage, see Compressor data table. Copyright 1994 Carrier Corporation This document was created with FrameMaker Form 38YCA-4PD

2 Built-in-Reliability Components Includes a suction-tube accumulator that reduces the amount of liquid refrigerant that reaches the compressor; a low-pressure switch to stop the compressor if refrigerant charge is lost; a crankcase heater on units with reciprocating compressor and all 3-phase units to keep compressor oil warm and free of refrigerant for maximum lubricity; an internal compressor relief valve for high-pressure protection. Discharge Muffler Minimizes low frequency sound and pressure pulsation generated by compressor discharge gas. Defrost Control Board Incorporates a defrost relay, defrost timer, and low-voltage terminations. The defrost control is a time and temperature initiation/termination control which includes 3 field-selectable time periods of 30, 50, and 90 minutes. The control includes built-in 5-minute compressor delay for units equipped with scroll compressors (see Compressor data table). Weather-Protective Cabinet Steel is protected with a heavy coating commonly called galvanizing, and coated with a layer of zinc phosphate. A coat of modified polyester powder coating is then applied and baked-on, providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting rust-resistant, quality appearance. Unit Design All units are equipped with totally enclosed fan motors for greater reliability under rain and snow conditions. The large, wraparound coil uses copper tube and enhanced aluminum fin and is designed for optimum heat transfer during heating and cooling. The vertical air discharge carries the sound and air up and away from adjacent patio areas and foliage. Coils can be cleaned with a common garden hose. External Service Valves Both service valves are brass, front seating type. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. The 38YCA has sweat field connections. The 38YCN has mechanical field connections. Warranty Standard 1 year on parts. Additional 4 years on compressor. Model number nomenclature 38YCA Electric Heat Pump Nominal 01818,000 Btuh 042 Btuh 02424,000 Btuh 04848,000 Btuh 03030,000 Btuh 06060,000 Btuh 036 Btuh Electrical 3208/ / Series Packaging 2

3 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. Physical data UNIT SIZE SERIES 33/34 35/36 36/37, 36, 56, 66/ 37,, * Tube sizes are for lengths up to 50 ft. For lengths over 50 ft, consult Long-Line Application Guideline. NOTE: See unit Installation Instructions for proper installation. 32/33, 53, 63 32, 52, / 33, 53, 63 32, 52, / 33, 53, 63 OPERATING WT (lb) , REFRIGERANT Control Charge 15 ft CONDENSER FAN Air Discharge Air Qty (CFM) Motor RPM (60 Hz) 22 Piston / / / / /7.78 /10.25 Propeller Type, Direct Drive Vertical CONDENSER COIL Face Area (sq ft) / / / CONNECTION (in. ID) Vapor Liquid REFRIGERANT TUBES* (in. OD) Vapor Liquid Sweat 5/8 3/4 7/8 3/8 5/8 3/4 7/8 1-1/8 3/8 3

4 COMPRESSOR DATA COMPRESSOR MANUFACTURER & TYPE UNIT SIZE UNIT SERIES BRISTOL RECIP COPELAND RECIP , TECUMSEH RECIP ,, MILLENNIUM SCROLL , 56, , 048, , 52, COPELAND SCROLL 042, 048, , 53, 63 UNIT SIZE *Piston listed is for any approved coil combination. SERIES METERING DEVICE OUTDOOR PISTON INDOOR PISTON* , , , 56, ,, , , 53, , 52,, 33, 53, , 52,, 33, 53,

5 Accessories ORDERING NUMBER KAAWS0101AAA KAATD0101 KAAFT0101AAA KHAIR0101AAA Standard KSACY0101AAA Winter Start Control Time-Delay Relay Evaporator Freeze Thermostat Isolation Relay Cycle ProtectorUnits with scroll compressor Cycle ProtectorUnits with recip compressor DESCRIPTION KAAHS0601AAA Compressor Start Assist (Capacitor/Relay) s 018 (331, 341), 024 (351, 361), 030 (361, 371) KAAHS0701AAA N/A KAACS0201PTC Standard N/A Standard KAACH1201AAA Compressor Start Assist (Capacitor/Relay) 036 (371) 1 Phase Compressor Start Assist (Capacitor/Relay)3 Phase and Scroll Units Start Assist (PTC)s Phase Scroll Units Start Assist (PTC)s Phase Recip Units Start Assist (PTC)3 Phase Crankcase Heaters 018 (331, 341), 024 (351, 361), 030 (361, 371), 036 (371), All 3 Phase Crankcase Heaters 036 (361), Phase KSASH1101COP Sound Blankets 018 (331), 024 (351), 030 (371, 1) Standard Sound Blanket 030 (361), 036 (371, 1, 1) KSASH1301TEC Sound Blankets 018 (341), 024 (361) KSASH1901CYL Sound Blanket 036 (361, 561, 661) KSASH2001CYL Sound Blankets (321, 521, 1) KSASH1201COP Sound Blanket 036 (511, 531) KSASH0801TEC Sound Blanket 036 (521) KSASH1701COP Sound Blankets (331, 531, 631) KHAOT0301FST KHAOT0201SEC KHAIC0101AAA KHAIC0201AAA Outdoor Thermostat Secondary Outdoor Thermostat Interface Control (Optimizer II) Interface Control (Outdoor Thermostat and Lockout Relay) KHATX0901HSO** TXV (Hard Shut-off) 018 KHATX1001HSO** TXV (Hard Shut-off) 024 KHATX1101HSO** TXV (Hard Shut-off) 030 KHATX1201HSO** TXV (Hard Shut-off)s 036, 042 KHATX1301HSO TXV (Hard Shut-off) 048 KHATX1401HSO TXV (Hard Shut-off) 060 KHATX0201RPB TXV (RPB) 018 KHATX0301RPB TXV (RPB) 024 KHATX0401RPB TXV (RPB) 030 KHATX0501RPB TXV (RPB)s 036, 042 KHATX0601RPB TXV (RPB) 048 KHATX0701RPB TXV (RPB) 060 Standard KSAHI0201HPS KHALS0101LLS Not Available Not Available Low-Pressure Switch High-Pressure Switch Liquid Solenoid Valve (LSV) Support Feet Snow Rack P Low-Ambient Controller* (RCD) P S Filter DrierBi-flow s P S Filter DrierBi-flow s N/A Not applicable in this application. * Isolation relay required. Use with low-ambient controller. See Compressor data table. ** Hard shut-off TXV requires compressor start assist on recip compressors. See Compressor Data table. THERMOSTAT/SUBBASE PKG --HH--07AT HH--93AZ HH--93AZ HH--07AE--001 DESCRIPTION Thermostat, 2-Stage Heat, 1-Stage Cool, Auto/Manual Changeover F Subbase for Manual Changeover Thermostat Subbase for Auto Changeover Thermostat Thermostat (1 Piece) Night Setback, 2-Stage Heat, 1-Stage Cool F/ C Option, 5-2 Day Programmable 5

6 Accessory Description and Usage 1. Time-Delay Relay A SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.) 2. Evaporator Freeze Thermostat A SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where low-ambient controller has been added. 3. Isolation Relay A SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. SUGGESTED USE: All heat pumps where low-ambient controller has been added. 4. Compressor Start Assist-Capacitor/Relay Type Start capacitor and start relay gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Replacement installations with hard shut-off expansion valve or liquid line solenoid on indoor coil. Units installed with low-ambient controller. 5. Sound Blanket Wraparound sound attenuation cover for the compressor. Reduces the sound level by about 0.2 bels. SUGGESTED USE: Unit installed closer than 15 ft to quiet areasbedrooms, etc. Unit installed between 2 houses less than 10 ft apart. 6. Outdoor Thermostat A SPDT temperature actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point. SUGGESTED USE: Heat pump installations with multiple-stage supplemental heaters 7. Secondary Outdoor Thermostat A SPDT temperature actuated switch which turns on a third stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point. SUGGESTED USE: Heat pump installations where 3-stage operation of supplemental heaters is desired. 8. Interface Control (Optimizer II) An electric control for controlling a heat pump and gas or oil furnace system for maximum energy savings. It allows heat pump to operate down to a predetermined economic balance point temperature, then switches to allow furnace operation only below that temperature. Requires outdoor thermostat (Item 6) to be adjusted for economic balance point temperature. SUGGESTED USE: All heat pump and gas- or oil-fired furnace combination systems. 9. Thermostatic Expansion Valve (TXV) A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shut-off and RPB valves are available. SUGGESTED USE: For improved system performance in cooling mode. 10. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 425 psig. Provides additional protection against compressor damage due to loss of outdoor airflow. SUGGESTED USE: Installations exposed to very dirty outdoor air. Installations where condenser inlet air temperature exceeds 125 F (51.7 C). 11. Filter DrierBi-flow A device for removing contaminants from refrigerant circulating in an air conditioner or heat pump system; bi-flow for heat pumps. SUGGESTED USE: All field-connected split-system units. 12. Liquid Solenoid Valve (LSV) An electrically operated shut-off valve to be installed at the outdoor unit and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. Note: Compressor start assist capacitor/relay type (Item 4) must be used on single-phase reciprocating compressors. SUGGESTED USE: In certain long-line applications. (Refer to Long-Line Application Guideline.) 6

7 Electrical data OUTDOOR UNIT , 34 V/PH 60 Hz OPER VOLTS* COMPR Max Min LRA RLA * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. Time-delay fuse. Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 2%. ** If wire is applied at ambient greater than 30 C (86 F), consult Table of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article If other than uncoated (non-plated), 60 or 75 C (140 or 1 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). NOTE: Control circuit is 24v on all units and requires external power source. Copper wire must be used from disconnect to unit. All motors/compressors contain internal overload protection. Model 042 MCA value greater than 048 due to UL testing. FLA Full Load Amps HACR, Air Conditioning, Refrigeration LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps FAN FLA MCA MIN WIRE SIZE** 60 C/75 C MAX LENGTH (Ft) 60 C/75 C MAX FUSE OR HACR TYPE CKT BKR AMPS /14 70/ /14 50/ /14 50/ /14 35/ /14 40/ /12 50/ / /12 50/ /8 80/ /8 80/ /8 90/ /8 95/ /8 75/ /8 75/ /14 70/ /14 50/ /14 50/ /12 60/ /230/ /12 60/ /14 40/ /14 45/ /12 55/ /12 55/ /14 95/ /14 95/ /14 140/ / /14 145/ /14 145/ /14 130/ /14 130/

8 8 Combination ratings See notes on pg. 9. UNIT SIZE- SERIES AND SOUND RATING (Bels) INDOOR UNIT ARI STANDARD RATINGS* TC Seasonal Efficiency SEER High-Temp Low-Temp Seasonal Efficiency HSPF Factory- Supplied Enhancement Standard Rating Field-Supplied Accessory** TXV TC COP TC COP , /7.6 F(A,B)4ANF018 FA1ANA018 FA1ANA024 FB(5,4)AN(A,F)018 FB(5,4)AN(A,F)024 F(A,B)4ANF024 FD3ANA024 FF1ANA018 FF1ANA024 FG3AAA024 CC5A/CD5A/CD5BA018 CD3(A,B)A018 CC5A/CD5A/CD5BA024 CD3(A,B)A024 CE3AA024 CF5AA024 17,000 17,000 17,800 17,000 18,000 18,000 17,000 17,800 17,800 17,800 17,800 17,800 17,800 18,000 18,000 17,600 16,800 17,000 17, ,000 10,900 11,400 11,000 11,400 11,400 11,200 11,000 11,300 11,200 11,000 11,000 11,200 11,200 11,200 11, , /7.6 F(A,B)4ANF024 F(A,B)4ANF030 FD3ANA024 FD3ANA030 FF1(A,B)NA024 FF1(A,B)NA030 CC5A/CD5A/CD5BA024 CD3(A,B)A024 CC5A/CD5A/CD5BA030 CC5A/CD5A/CD5BW030 CD3(A,B)A030 CE3AA024 CE3AA030 CF5AA024 22,600 22,000 23,000 22,000 23,000 22,400 22,400 22,600 23,000 22, ,900 13,900 13,600 14,000 14,000 14,100 13,700 13,700 13,800 13,800 13,800 13,900 14,000 13, , 37, 8.0/7.6 F(A,B)4ANF030 F(A,B)4ANF036 FD3ANA030 FF1(A,B)NA030 FG3AAA036 CC5A/CD5A/CD5BA030 CC5A/CD5A/CD5BW030 CD3(A,B)A030 CC5A/CD5A/CD5BA036 CD5A/CD5BW036 CD3(A,B)A036 CE3AA030 CE3AA036 CF5AA036 28,200 28,000 28,200 28,200 27,800 27,800 27,800 28,600 28,600 28,600 28,000 28,200 28,200 29,000 29,200 29,000 29,000 29,000 28,600 28,600 28,600 29,200 29,200 29,200 29,000 29,000 29, ,100 17,300 17,400 17,200 17,000 17,000 17,000 17,300 17,300 17,300 17,200 17,200 17, , 56, 66, 37,, 8.0/7.6 F(A,B)4ANF036 F(A,B)4AN(F,B)042 FG3AAA036 CC5A/CD5A/CD5BA036 CD5A/CD5BW036 CD3(A,B)A036 CC5A/CD5A/CD5BA042 CD3(A,B)A042 CC5A/CD5A/CD5BA043 CC5A/CD5A/CD5BW042 CC5A/CD5A/CD5BW043 CE3AA036 CE3AA042 CF5AA036 34,200 34,800 34,000 34,200 34,200 34,200 34,800 34,800 34,400 34,400 34,400 34,200 34,600 34, ,000 21,000 20,600 20,800 20,800 20,800 20,800 20,800 20,800 20,600 20,800 20,600 20,800 20, , 52, 33, 53, /8.0 F(A,B)4AN(F,B)042 F(A,B)4AN(F,B)048 FG3AAA048 CC5A/CD5A/CD5BA042 CD3(A,B)A042 CC5A/CD5A/CD5BA043 CC5A/CD5A/CD5BW042 CC5A/CD5A/CD5BW043 CD5A/CD5BA048 CD3(A,B)A048 CC5A/CD5A/CD5BC048 CC5A/CD5A/CD5BW048 CE3AA042 CE3AA048 CF5AA048 40,500 41,000 41,000 40,500 40,500 40,500 40,500 40,500 41,000 41,000 40,500 41,000 41,000 41,000 41, ,600 28,800 28,600 28,

9 Combination ratings continued ARI STANDARD RATINGS* UNIT SIZE- SERIES AND SOUND RATING (Bels) , 52,, 33, 53, / , 52,, 33, 53, /8.0 INDOOR UNIT F(A,B)4AN(F,B)048 F(A,B)4AN(F,B)060 FB4ANB070 FG3AAA048 FG3AAA060 CD5A/CD5BA048 CD3(A,B)A048 CC5A/CD5A/CD5BC048 CC5A/CD5A/CD5BW048 CC5A/CD5A/CD5BA060 CD3(A,B)A060 CC5A/CD5A/CD5BW060 CE3AA048 CE3AA060 CF5AA048 F(A,B)4AN(F, B)060 FB4ANB070 FG3AAA060 CC5A/CD5A/CD5BW060 CD3(A,B)A060 CC5A/CD5A/CD5BW060 CE3AA060 TC 46,000 46,500 47,000 45,000 46,000 45,000 45,000 44,000 45,000 45,000 45,000 46,000 45,000 46,000 45,000 56,000 56,500 54,500 53,500 53,500 55,500 56,000 Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Field-Supplied Accessory** High-Temp Low-Temp TXV TC COP TC COP ,000 47,000 47,000 47,000 47,000 46,500 46,500 46,000 46,500 46,500 46,500 47,000 47,000 47,000 46,500 58,000,000 56,500 56,000 56,000 56,500 56, ,600 29, ,200 29, ,800 29,200 29,000 29,000 29,200 29, ,500 39,500 39,000 38,500 38,500 39,000 39, Seasonal Efficiency HSPF COP Coefficient of Performance TC (Btuh) HSPF Seasonal Performance Factor Time-Delay Relay SEER Seasonal Energy Efficiency Ratio TXV Thermostatic Expansion Valve * Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Standard: 80 F (27 C) db F (19 C) wb indoor entering air temperature and 95 F (35 C) db air entering outdoor unit. High-Temperature Standard: 70 F (21 C) db indoor entering air temperature and 47 F (8 C) db 43 F (6 C) wb air entering outdoor unit. Low-Temperature Standard: 70 F (21 C) db indoor entering air temperature and 17 F ( 8 C) db 15 F (11 C) wb air entering outdoor unit. Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined under DOE computer simulation procedures. Without/with accessory sound blanket. ** See.90 table. TXV must be hard shut-off type. 7.6 rating for 030 (371, 1) and 036 (361) units only. METHOD Time-Delay Relay Furnaces with.90 TABLE KAATD0101 PART/MODEL NO. 58DHC, 58DX, 58DXA, 58DXC, 58EJA, 58EJB, 58MCA, 58MVP, 58MXA, 58PAP, 58PAV, 58RAP, 58RAV, 58SSC, 58SX, 58SXA, 58SXB, 58TMA, 58TUA, 58VCA, 58VUA, 58WAV, 58ZAV NOTE: In most cases, only 1 of the above should be used to achieve function. More than 1 of the methods listed above in a system may cause degradation in performance. 9

10 Detailed cooling capacities* EVAPORATOR AIR CFM EWB CC5A/CD5A/ CD5BA See notes on pg. 13. CONDENSER ENTERING AIR TEMPERATURES F Sens KW** Sens KW** Sens KW** Sens KW** Sens YCA018-33, 34 Outdoor With F(A,B)4ANF Multipliers for Determining the Performance With Other s FA1ANA CD3(A,B)A FC4ANF FD3ANA CE3AA FF1ANA CF5AA FB(4,5)AN(A,F) F(A,B)4ANF FG3AAA YCA/YCN024-35, 36 Outdoor With F(A,B)4ANF Multipliers for Determining the Performance With Other s F(A,B)4ANF CD3(A,B)A FD3ANA CC5A/CD5A/CD5BW CE3AA FF1(A,B)NA CC5A/CD5A/ CD5BA CF5AA KW**

11 Detailed cooling capacities* continued EVAPORATOR AIR CFM EWB See notes on pg. 13. CONDENSER ENTERING AIR TEMPERATURES F Sens KW** Sens KW** Sens KW** Sens KW** Sens YCA030-36, 37, Outdoor With F(A,B)4ANF Multipliers for Determining the Performance With Other s F(A,B)4ANF CC5A/CD5A/CD5BW CD3(A,B)A FD3ANA FF1(A,B)NA CD5A/CD5BW FG3AAA CE3AA CC5A/CD5A/ CD5BA CF5AA YCA/YCN036-36, 56, 66, 37,, Outdoor With F(A,B)4ANF Multipliers for Determining the Performance With Other s F(A,B)4ANF CD3(A,B)A F(A,B)4AN(F,B) FG3AAA CC5A/CD5A/ CC5A/CD5A/ CD5BA CD5BW CE3AA CD5A/CD5BW CF5AA KW**

12 Detailed cooling capacities* continued EVAPORATOR AIR CFM EWB See notes on pg. 13. CONDENSER ENTERING AIR TEMPERATURES F Sens KW** Sens KW** Sens KW** Sens KW** Sens 38YCA/YCN042-32, 33, 53, 63 Outdoor With F(A,B)4AN(F,B) Multipliers for Determining the Performance With Other s F(A,B)4AN(F,B) CC5A/CD5A/ CD5BW FG3AAA CC5A/CD5A/ CD5BA CD5A/CD5BA CC5A/CD5A/CD5BC CD3(A,B)A CE3AA CF5AA YCA/YCN048-32, 52,, 33, 53, 63 Outdoor With F(A,B)4AN(F,B) Multipliers for Determining the Performance With Other s F(A,B)4AN(F,B) CC5A/CD5A/CD5BC CC5A/CD5A/ FB4ANB CD5BW FG3AAA CC5A/CD5A/CD5BA CE3AA CD5A/CD5BA CD3(A,B)A CF5AA KW**

13 Detailed cooling capacities* continued EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES F Sens KW** Sens KW** Sens KW** Sens KW** Sens 38YCA060-32, 52,, 33, 53, 63 Outdoor With F(A,B)4AN(F,B) KW** * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 ft of tubing. If other than 25 ft of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. and sensible capacities are net capacities. Blower motor heat has been subtracted. Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). ** kw is total of indoor and outdoor unit kilowatt s. At TVA rating indoor condition (75 edb/63 ewb). All other indoor air temperatures are at 80 edb. EWBEntering Wet Bulb Multipliers for Determining the Performance With Other s F(A,B)4AN(F,B) CD3(A,B)A FB4ANB CC5A/CD5A/ FG3AAA CD5BW CC5A/CD5A/CD5BA CE3AA

14 Heat pump heating performance INDOOR AIR See notes on pg. 17. OUTDOOR COIL ENTERING AIR TEMPERATURES F EDB CFM Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw 38YCA018-33, 34 Outdoor With F(A,B)4ANF CC5A/CD5A/ CD5BA Multipliers for Determining the Performance With Other s FA1ANA CD3(A,B)A FC4ANF FD3ANA CE3AA FF1ANA CF5AA FB(4,5)AN(A,F) FG3AAA F(A,B)4ANF YCA/YCN024-35, 36 Outdoor With F(A,B)4ANF Multipliers for Determining the Performance With Other s F(A,B)4ANF CD3(A,B)A FD3ANA CC5A/CD5A/CD5BW CE3AA FF1(A,B)NA CF5AA CC5A/CD5A/CD5BA

15 Heat pump heating performance continued INDOOR AIR See notes on pg. 17. OUTDOOR COIL ENTERING AIR TEMPERATURES F EDB CFM Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw 38YCA030-36, 37, Outdoor With F(A,B)4ANF Multipliers for Determining the Performance With Other s F(A,B)4ANF CD3(A,B)A FD3ANA CD5A/CD5BW FF1(A,B)NA CE3AA FG3AAA CC5A/CD5A/CD5BA CF5AA CC5A/CD5A/CD5BW YCA/YCN036-36, 56, 66, 37,, Outdoor With F(A,B)4ANF Multipliers for Determining the Performance With Other s F(A,B)4ANF CD3(A,B)A F(A,B)4AN(F,B) FG3AAA CC5A/CD5A/CD5BW CC5A/CD5A/CD5BA CE3AA CD5A/CD5BW CF5AA

16 Heat pump heating performance continued INDOOR AIR See notes on pg. 17. OUTDOOR COIL ENTERING AIR TEMPERATURES F EDB CFM Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw 38YCA/YCN042-32, 33, 53, 63 Outdoor With F(A,B)4AN(F,B) Multipliers for Determining the Performance With Other s F(A,B)4AN(F,B) CC5A/CD5A/CD5BW FG3AAA CC5A/CD5A/CD5BA CD5A/CD5BA CC5A/CD5A/CD5BC CD3(A,B)A CE3AA CF5AA YCA/YCN048-32, 52,, 33, 53, 63 Outdoor With F(A,B)4AN(F,B) Multipliers for Determining the Performance With Other s F(A,B)4AN(F,B) CC5A/CD5A/CD5BC CC5A/CD5A/CD5BW FB4ANB FG3AAA CC5A/CD5A/CD5BA CE3AA CD5A/CD5BA CD3(A,B)A CF5AA

17 Heat pump heating performance continued INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES F EDB CFM Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw Integ Kw 38YCA060-32, 52,, 33, 53, 63 Outdoor With F(A,B)4AN(F,B) The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to obtain total system kw s. EDBEntering Dry Bulb Multipliers for Determining the Performance With Other s F(A,B)4AN(F,B) CD3(A,B)A FB4ANB CC5A/CD5A/CD5BW FG3AAA CE3AA CC5A/CD5A/CD5BA Design 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature for cooling mode without low-ambient operation accessory is 55 F (12.8 C). 3. Maximum outdoor operating air temperature for cooling mode is 125 F (51.7 C), except some 3 phase models is 115 F (46.7 C). 4. Minimum outdoor operating air temperature for heating mode is 30 F ( 34.4 C). 5. Maximum outdoor operating air temperature for heating mode is 66 F (18.9 C). 6. For reliable operation, unit should be level in all horizontal planes. 7. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. (See items 8 and 9 following.) 8. For interconnecting refrigerant tube lengths greater than 50 ft, consult Long-Line Application Guideline available from equipment distributor. 9. Not more than 36 in. of refrigerant tube should be buried in the ground. If necessary to bury tubes under a sidewalk, provide a minimum 6-in. vertical rise to the valve connections at the unit. 10. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 11. Mixmatches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comfort. 17

18 Certified drawing38yca UNIT SERIES ELECTRICAL CHARACTERISTICS A B C D E F G H J K L M N P SHIPPING WEIGHT 38YCA018 38YCA024 38YCA030 38YCA030 38YCA030 38YCA036 38YCA042 38YCA042 38YCA048 38YCA048 38YCA060 3,4 5, , ,3 X O X O X O X O X O X O X O X O X O X O X O O O O O X X X X X X X O O O O O X 30 X 30 X 30 X 30 X 30 X # 148# 155# 1# 158# 181# 212# 212# 224# 222# 242# / X = YES O = NO M AIR IN AIR DISCHARGE A SQ AIR DISCHARGE AIR IN N 3/8 DIA TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN J K AIR IN L B FIELD POWER SUPPLY CONN 7/ 8 DIA HOLE WITH 1 1 / 8 DIA KNOCKOUT AND 1 3 / 8 DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 / 8 DIA HOLE 3/ 8 DIA LIQUID LINE CONN AIR DISCHARGE UNIT SIZE E 18, 24, x , 48, 60 MINIMUM MOUNTING PAD DIMENSIONS 30 x 30 AIR IN F G H P D DIA SERVICE LINE CONN 1 1 /4 2 7 /8 NOTES: 1. ALLOW 30 CLEARANCE TO SERVICE SIDE OF UNIT, 48 ABOVE UNIT, 6 ON ONE SIDE, 12 ON REMAINING SIDE, AND 24 BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55 F, MAX 125 F. 3. MAXIMUM OUTDOOR OPERATING AMBIENT IN HEATING MODE IS 66 F. 4. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 5. CENTER OF GRAVITY C 18

19 Certified drawing38ycn UNIT SERIES ELECTRICAL CHARACTERISTICS A B C D E F G H J K L M N P SHIPPING WEIGHT 38YCN024 38YCN030 38YCN030 38YCN036 38YCN042 38YCN042 38YCN048 38YCN048 5,6 5,7 6 6, X O O X O O X O O X O O X O O X O O X O O X O O O O O O 30 O 30 O 30 O 30 O # 155# 1# 181# 212# 212# 224# 222# / X = YES O = NO M AIR IN AIR DISCHARGE A SQ AIR DISCHARGE AIR IN N 3 /8 DIA TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN J K AIR IN L B FIELD POWER SUPPLY CONN 7/ 8 DIA HOLE WITH 1 1 / 8 DIA KNOCKOUT AND 1 3 / 8 DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 / 8 DIA HOLE 3/ 8 DIA LIQUID LINE CONN AIR DISCHARGE UNIT SIZE 24, 30 36, 42, 48 E MINIMUM MOUNTING PAD DIMENSIONS x x 30 AIR IN F G H P D DIA SERVICE LINE CONN 1 1 /4 2 7 /8 NOTES: 1. ALLOW 30 CLEARANCE TO SERVICE SIDE OF UNIT, 48 ABOVE UNIT, 6 ON ONE SIDE, 12 ON REMAINING SIDE, AND 24 BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55 F, MAX 125 F. 3. MAXIMUM OUTDOOR OPERATING AMBIENT IN HEATING MODE IS 66 F. 4. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 5. CENTER OF GRAVITY C 19

20 Printed in U.S.A OUTDOOR TEMPERATURE, F BUILDING HEAT LOSS, 1000 BTU/HR UNIT INTEGRATED HEATING CAPACITY, 1000 BTU/HR 70 F AND AT RATED CFM BASED ON INDOOR ENT. AIR AT YCA01833/34 F(A,B)4ANF YCA02435/36 F(A,B)4ANF YCA03036/37 F(A,B)4ANF030 38YCA03636/37 F(A,B)4ANF YCA04232/33 F(A,B)4AN(F,B) YCA04832/33 F(A,B)4AN(F,B) YCA06032/33 F(A,B)4AN(F,B) YCA BALANCE POINT WORKSHEET KW

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES AVAILABLE SIZES: 18,000 to 60,000 Btu CERTIFICATION: U.L., c-ul, ARI and CEC Listed ELECTRICAL RANGE: 208 230v, 60 Hertz, 1 Phase COMPRESSOR PROTECTION: Each compressor is protected with internal temperature-

More information

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling PAYNE Heating & ELECTRIC CONDITIONER 710A (60 Hz) Sizes 018 thru 060 Model 710A Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable summer cooling performance.

More information

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38YCC 50 Hz Heat Pump Sizes 024 thru 060 The 38YCC 50 Hertz Outdoor s of Split-System Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With

More information

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: With SEER of at least 10.0 and HSPF of 6.8,

More information

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: ELECTRICAL RANGE: FAN MOTOR: CABINET: UNIT

More information

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Product Data 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Carrier s WeatherMaker 38TXA with Puron provides a completely unique collection of features which cannot be matched by

More information

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant, AVAILABLE SIZES: CERTIFICATION: Nominal sizes available from 018 through 060 to meet the needs of residential and light commercial applications. All models are listed with UL, c-ul, ARI, CEC, and CSA-

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38BYG (60 Hz) 12 SEER Heat Pump s 018 thru 060 The 38BYG Outdoor s of Split- Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER

More information

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS Product Data 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 The 38CKS Air Conditioner is designed for superior performance durability in harsh environments. The product achieves

More information

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant Product Data 38YXA (60Hz) Deluxe 13 SEER Split- Heat Pump with Puron (R-410A) Refrigerant Sizes 024 thru 060 INTRODUCING THE WEATHERMAKER 38YXA HEAT PUMP FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

More information

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1 QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT 650A (60 Hz) Sizes 024 thru 060 The Quantum Plus line of split-system outdoor units has been expanded to include the Model 650A 13 SEER heat pump (with

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable cooling performance.

More information

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS. (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1 --- 1/2 to 5 Nominal Tons) Product Data The Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES: (60 Hz) 13 SEER Air Conditioner Sizes 018 --- 060 Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38BRC (60 Hz) Air Conditioner Sizes 024 thru 060 Model 38BRC Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES: AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS (018-060) Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC 50 Hz Air Conditioner Sizes 018 thru 060 Model 38CKC 50 Hertz energyefficient air conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data. Efficiency. S S Reliability

Product Data. Efficiency. S S Reliability 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH14 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

A 14 SEER Heat Pump with R---410A Refrigerant Series

A 14 SEER Heat Pump with R---410A Refrigerant Series MODEL NUMBER NOMENCLATURE PH14 N B 018 00G B A 14 SEER Heat Pump with R---410A Refrigerant Series Electrical Supply N=208/230---1 P=208/230---3 E=460/3 B R---410A Nominal Capacity 018 1 1/2Tons 024 2Tons

More information

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES 10 SEER HEAT PUMP UNIT 661C Sizes 018 thru 060 The 661C Outdoor Section of Split- Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER up to 11.5

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S BH13NA 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH13 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11 12 SEER ELECTRIC AIR CONDITIONER 563C (60 Hz) Sizes 024 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS. Performancet 16 2 --- Stage Heat Pump with Puronr Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with Puron r refrigerant provide a collection of features

More information

697C (60 HZ) Sizes 018 thru 060

697C (60 HZ) Sizes 018 thru 060 SPLIT-SYSTEM HEAT PUMP UNITS 697C (60 HZ) s 018 thru 060 The AeroQuiet System (AQS) consists of 4 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and

More information

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8 ELECTRIC AIR CONDITIONER 597C (60 Hz) Sizes 018 thru 060 The Reliant AeroQuiet System (AQS) consists of 3 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCD

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched by

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Product Data 38EYA (60Hz) 12 SEER Split- Cube Heat Pump with Puron Refrigerant Sizes 018 thru 060 FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Carrier s technological leadership has risen to a

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1 12 SEER ELECTRIC AIR CONDITIONER 563G (60 Hz) Sizes 018 thru 060 Model 563G Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data PA13NA PA13PA FEATURES AND BENEFITS PA13NA PA13PA 13 SEER Split---System Air Conditioner With R---410A Refrigerant Single & Three Phase 1 --- 1/2 To 5 Tons Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from

More information

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES Product Data 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant Sizes 018 thru 060 Carrier s technological leadership has risen to a new level with the development of the 38EYG Heat Pump, the outdoor

More information

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38EZG (60 Hz) Air Conditioner with Puron Sizes 018 thru 060 Copyright 2003 Carrier Corporation Model 38EZG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet,

More information

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5 12 SEER AIR CONDITIONER 563C Sizes 018 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are

More information

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4 DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) 550A (60 Hz) Sizes 024 thru 060 Bryant s Quantum Plus 550A with Puron provides a completely unique collection of features which cannot be matched by any

More information

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant Sizes 018 thru 060 Model 38ETG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS Product Data Bryant Air Conditioners with refrigerant provide a collection of features unmatched by any other

More information

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Product Data Bryant Heat Pumps with Puronr refrigerant provide a collection of features unmatched by any other family

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton PRODUCT NUMBER NOMENCLATURE 14 SEER Air Conditioner with Refrigerant PA14 N C 018 00G B A Series Variations Electrical Supply N 208/230 60 1 00G Variations C Nominal Capacity 018 1 1/2Ton 024 2Tons 030

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4**C Comfort 14 Heat Pump for Coastal Applications with r Refrigerant 1---1/5 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5 -- 11.7 EER / 8.2 HSPF

More information

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

INDUSTRY LEADING FEATURES 2 5 / BENEFITS Infinityr 19 2 --- Stage Heat Pump with Puronr Refrigerant 2to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t Infinityr 15 Heat Pump with Puronr Refrigerant 2to4NominalTons(Sizes24---48) Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Baset13 Air Conditioner with Puronr Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other

More information

Product Data. Efficiency

Product Data. Efficiency BH14NB SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5-11.7 EER / 8.2 HSPF S Microtube Technologyt refrigeration

More information

Advance Product Data

Advance Product Data Comfort 14 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Advance Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons 116B Legacyt Line 16 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability 25HPB6 Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Tons Product Data the environmentally sound refrigerant Carrier heat pumps with Puronr refrigerant provide a collection of features

More information

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24AHA4 Performance Series Air Conditioner with Refrigerant 1-1/2 to 5 Nominal Tons Product Data Carrier air conditioners with refrigerant provide a collection of features unmatched by any other family

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. CA13NA 018 060 Base Series Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s non -ozone depleting refrigerant. INDUSTRY LEADING FEATURES / BENEFITS Efficiency

More information

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4 Comfort 14 Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound 24VNA0 Infinityr Variable Speed Air Conditioner with Greenspeedr Intelligence 2to5NominalTons Product Data Carrier s 24VNA0 with Greenspeed R Intelligence is a variable speed cooling product providing

More information

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24ABC6 Comfortt16 Air Conditioner with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier Heat Pumps with Puronr refrigerant provide a collection of features

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060 Product Data Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant Sizes 018 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design

More information

Advance Product Data

Advance Product Data Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3 DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT 652A Sizes 018 thru 060 TM The 652A split-system outdoor unit is a 12 SEER heat pump (with efficiencies up to 14.0 SEER). Homeowners will appreciate this

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Advance Product Data

Advance Product Data EVOLUTION R V VARIABLE SPEED AIR CONDITIONER WITH PURONr REFRIGERANT 2, 3, AND 4-TON (5-TON COMING Q4 2014) Advance Product Data The Evolution V air conditioner offers high -efficiency variable speed performance

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 114CNC Legacyt Line Air Conditioner for Coastal Applications with r Refrigerant 1--1/2 To 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14.0 SEER / 11.0 13.5 EER S Microtube

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Advance Product Data

Advance Product Data EVOLUTION R EXTREME VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT (2-5 Ton) Advance Product Data Bryant s Evolutionr Extreme is a breakthrough product providing up to 13 HSPF heating efficiency and

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

R 410A Ducted Horizontal Air Conditioner

R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS, 208/230

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES Product Data Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant Sizes 024 thru 060 Carrier s Performance 14 Air Conditioners with Puron refrigerant provide a collection of features unmatched

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information