1 Vacuum Pump Kit User Manual 2I

2

3 Vacuum Pump Kit User Manual 2I

4 Vacuum Pump Kit Vacuum Pump Kit P/N GS03640 CONTENTS 1. INTRODUCTION CHECKLIST OF CONTENTS OPERATION OF THE VACUUM PUMP PUMP MOTOR AND GENERAL SAFETY INLET MANIFOLD CONNECTIONS SPECIFICATIONS FOR THE VACUUM PUMP KIT SPARE PARTS FOR THE VACUUM PUMP KIT VACUUM PUMP KIT BUBBLE NUMBER PARTS IDENTIFICATION LIST April 2016 Specac Ltd. All rights reserved. Brilliant Spectroscopy is a trademark of Specac Ltd. Other product names mentioned herein may be trademarks of their respective owners. 2

5 User Manual 1. Introduction Thank you for buying a product from Specac. The Vacuum Pump GS03640 is a dual voltage operation (220 volts and 110 volts - two stage) vacuum pump capable of pulling a vacuum to 0.05 Torr or better. It is an ideal vacuum pump to use with the Specac Accessories that have the capability of being operated under these vacuum conditions. The vacuum pump has the following features. It is designed for normal starting in low temperature and low voltage conditions. (Typically temperatures at or above 5 C with a +/- 10% rated voltage. An air passage prevents any pump oil from returning into the pipeline or vacuum vessel being pumped after the vacuum pump is stopped. There is an inbuilt oil mist eliminating device and it has an oil/gas separator at the air exhaust outlet which removes any oil contamination in the air exhaust. The pump operates at a high ultimate vacuum with low noise. Each vacuum pump has been factory tested for its vacuum pump speed in both CFM and micron units. The Vacuum Pump GS03640 is supplied along with an appropriate kit of parts (a pressure gauge, vacuum tubing and particular connecting unions) compatible for immediate use with the appropriate Specac accessories. Please take time to familiarize yourself with the features and the operating instructions of this vacuum pump. Routine care and maintenance of the vacuum pump will provide years of reliable service. 3

6 Vacuum Pump Kit 2. Checklist of Contents Check that the following items have been supplied: Vacuum pump P/N GS03640 with appropriate power control (mains) cable. Pressure gauge and fittings. Special pipework and fittings for connectivity and operation whilst evacuating an appropriate Specac Accessory. (See list of accessories in Section 5 of this manual).. Container of oil to fill vacuum pump (275mls). Unpack the Vacuum pump and parts carefully and prepare the items for use. WEEE Directive For Equipment Disposal The symbol (above) on the back of the vacuum pump indicates that this product complies with the Waste Electrical and Electronic Equipment Directive (WEEE). If this product is in use and was purchased within the European Union, please contact your local sales agent or Specac to make arrangements for disposal of this equipment. 4

7 User Manual 3. Operation of the Vacuum Pump Warning! Before the vacuum pump can be operated it must first be filled with oil. A container of approximately 275mls of oil has been supplied with the vacuum pump. The oil capacity of this two stage pump is 260mls. This oil must be used for operation of the vacuum pump. Use of any other oil type, or a contaminated oil will invalidate any warranty on the vacuum pump Fig 1.Two Stage (Dual Voltage Capability) Vacuum Pump GS

8 Vacuum Pump Kit Filling With Oil This vacuum pump has been factory tested and supplied with only trace amounts of oil. Oil must be added before operation. Failure to add any oil will damage the vacuum pump and invalidate any warranty. See Fig 1. for identification of parts described. 1) Make sure the oil drain valve plug (1) located below the pump front casing is closed before attempting to fill with oil. (Screw clockwise.) 2) Remove the red coloured oil fill cap (2) from the top of the vapour discharge/exhaust and oil filling port (3). Note: The cap (2) is a dust cover used for initial transportation purposes before use of the vacuum pump. In operation of the vacuum pump the cap (2) must be removed, but the cap (2) should be retained and placed back in position when the vacuum pump is not operating or is being stored. 3) Insert the oil container into the fill port (3). Note: The vapour discharge/oil fill port (3) is easily removable if required. It contains an internal check valve to prevent escape of liquid oil. 4) Slowly add oil until the oil level rises towards the top (maximum indicator) of the oil level sight glass (4). (There is a maximum and minimum level indicator.) Take care not to overfill with oil. The oil capacity is 260mls. Checking the Oil Level 5) Open the gas ballast valve (5) one complete turn anticlockwise. This valve is the small brass knurled and threaded knob fitting located next to the carry handle (6). 6) Close the pump inlet manifold valve handle (7) by turning clockwise before switching on the vacuum pump to check the oil level. 6

9 User Manual 7) Now turn on the vacuum pump. There is an on/off rocker switch (8) on the motor cover housing. Next to the on/off switch (8) is a protected slide switch (9) which allows for change of the voltage supply between 220volts or 110 volts for operation of the vacuum pump. Warning: Before switching on the vacuum pump check that the slide switch (9) is set for your mains voltage supply. The switch (9) position for voltage can be changed by placing the blade of screwdriver into the tab recess on the switch and sliding up or down as required. 8) Switch on the pump and run for two minutes. Observe the oil level while the pump is running. The oil level seen through the sight glass (4) should be between the maximum and minimum levels. 9) If the oil level is low, slowly open the inlet manifold handle (7) by turning anticlockwise and run the pump for a further 15 seconds, then stop the pump (switch (8) off ) and observe the oil level again. Add a small amount of oil as needed by following the step at 4). Evacuation Performance The Gas Ballast Valve (5) The gas ballast valve (5) must be partially opened (one turn anticlockwise) for the first part of any evacuation procedure. After about two minutes of pumping, close the valve (5) by turning clockwise and continue the evacuation procedure to reach an ultimate vacuum. Failure to close the gas ballast valve during high vacuum operation will result in a poor vacuum performance. During the first stages of an evacuation, vapours are highly concentrated. Unfortunately in some instances vapours will condense into a liquid and mix with the oil, thus reducing the oil s ability to produce a deep vacuum. The gas ballast valve (5) emits a controlled amount of dry air into the pump during compression to minimise condensation and keep the oil relatively clean during the first part of 7

10 Vacuum Pump Kit any evacuation procedure. It is therefore advised that periodically you should remove the gas ballast valve (5) (unscrew completely) and clean it from any contaminants or particulates to unblock the airways and clean or replace its sealing O-ring. Before replacing and tightening the gas ballast valve (5) back into the pump, lightly coat threaded surfaces with some of the vacuum pump oil. Changing Oil For the vacuum pump to reach an optimum pumping performance for a deep vacuum requirement, it needs clean, moisture free oil during evacuation. Dirty oil becomes a mixture of corrosive acids and water that affects the pumps ability to pull a deep vacuum. If dirty oil is left sitting in the pump, the sludge will rust and corrode internal surfaces of the vacuum pump thus shortening the pump s life. Specac recommends that after every evacuation procedure the oil should be checked for any contamination that may impair the performance of the vacuum pump. Care Safety Warning! Care must be taken when checking the oil to avoid contact with skin or eyes. Wear gloves and protective spectacles. The oil may be hot! Used oil must be properly disposed of in a leakproof corrosive resistant container according to local regulations. After every evacuation, while the pump is warm and the oil is thin, take a small sample of oil from the drain valve port (1). If the oil is contaminated, drain the oil from the pump by placing the vacuum pump on a level surface and open up the drain valve (1). Collect the waste oil in a suitable container and dispose it properly. If the vacuum pump has been sitting idle for more than one month, the oil is considered as contaminated, regardless of its appearance and should be changed as outlined above. To fill with new oil, follow the procedure as outlined in steps 1) to 4) on page 6. 8

11 User Manual 4. Pump Motor and General Safety General Safety! For general operation of the vacuum pump P/N GS03640, the pump and oil must be in a temperature environment above 1 C (0 F). The power line voltage supply must be within + or 10% to the voltage rating on the pump motor nameplate. The normal operating temperature of the pump is approximately 71 C (160 F) and so the pump is hot to touch. The line voltage and the general ambient temperature will affect the normal operating temperature. The vacuum pump is designed for continuous duty and will run for extended periods without overheating. The pump motor has an automatic resetting thermal overload protection feature. If the motor will not start the pump, the thermal protection feature may have become enabled. Therefore, disconnect the pump from the system, wait for about 15 minutes to allow the motor to cool down and then try switching on and operating again. Warnings A) Do not evacuate combustible, explosive or poisonous gases. B) Do not evacuate gases that corrode metal or will react chemically with the pump oil. C) The temperature of the evacuated gas shall not exceed 80 C (176 F) and the ambient temperature shall be between 5 C (41 F) and 60 C (140 F). D) Do not operate the pump without oil. E) Do not touch the pumps hot surfaces during operation. F) Do not block the air/exhaust outlet. As a caution, to reduce the danger of electrical shock, keep the pump indoors and do not expose it to rain or wet conditions. 9

12 Vacuum Pump Kit Dangers G) With an electrical socket that is grounded, the operating voltage is rated at + or 10%. The electrical connection must be well grounded, or else electrical shock may be caused. Should the power cord or plug require repair or replacement, do not connect the grounded wire to any flat adapter connector. If you are in doubt about the correct connectivity for grounding, seek professional help from a qualified electrician. Do not change the structure of the supplied power adaptor plug. H) When pulling out the power plug from its socket, pull the plug and not the cable. I) Do not place heavy objects on, or constrict the power cable. J) Do not use a broken plug or socket. K) Do not pull out the power plug when hands are wet. L) Do not pull out, insert the power plug or switch on power to the pump where flammable gases may be present. 10

13 User Manual 5. Inlet Manifold Connections The two stage Vacuum Pump P/N GS03640 is ideal to use with Specac s range of accessories that are capable of being operated under vacuum conditions of 0.05Torr or better. The list of Specac accessories that can be connected to the Vacuum Pump P/N GS03640 are as follows. Part Number Description Accessory Vacuum Fitting GS03000 Atlas Evacuable 8mm O.D. ribbed Pellet Dies GS03550, GS03700 Specadie 8mm O.D. ribbed GS05670 Storm 10H Gas Cell 1/8 BSP Threaded PEEK to Swagelok GS05850, GS05855 GS19930 GS21525 GS21530 GS24102, GS24105, GS24110, GS24120 GS24205, GS24210, GS24220 GS25410, GS25411 High Temperature High Pressure Cell Environmental Chamber Variable Temperature Cell Holder Variable Temperature Cuvette Holder Cyclone Long Pathlength Gas Cells Tornado Long Pathlength Gas Cells Atlas Lightweight Evacuable Pellet Dies connector 1/4 BSP Threaded PEEK to Swagelok connector VCO threaded connection to 1/4" O.D. tubing 3/8 O.D. barb connector 3/8 O.D. barb connector 1/4 O.D. gas outlet barbed connector 1/4 O.D. gas outlet connector 8mm O.D. ribbed The Vacuum Pump Kit P/N GS03640 has been supplied with specific parts for the inlet manifold (7) connection port to allow for easy connection and use of any of the accessories as listed in the table above for vacuum operation. 11

14 Vacuum Pump Kit For use of the Vacuum Pump Kit with ANY Specac accessory the parts that consist of the pressure gauge to the T connector, vacuum pump connection and large size bore vacuum tubing must be fitted to the central top inlet port of the valve manifold (7) vacuum pump as seen from Fig 2. The vacuum pump connection fitting is tightened in a clockwise direction to the central top port of the valve (7). 7 Fig 2. T-Connector, Pressure Gauge and large bore tubing assembly fitted to central manifold port (7) of the vacuum pump 12

15 User Manual Fig 3 shows the vacuum tubing assembly parts that are connected to the Vacuum Pump as shown in Fig 2. Depending upon which Specac accessory you are using specific connection parts of tubing and connectors have been supplied that are variously fitted into the open end of the large bore vacuum tubing of this assembly of parts. 10 Fig 3. T-Connector, Pressure Gauge and large bore tubing that fits to the central manifold port (7) of the vacuum pump For Use with the Variable Temperature Cell Holder GS21525, Variable Temperature Cuvette Holder GS21530 and Environmental Chamber GS19930 The open ended part of the large bore tubing (10) seen in Fig 3. is directly connected to the 3/8 O.D. barbed vacuum port connection on the top of the Variable Temperature Cell dewar part and to an outlet VCO coupling with 1/4" tubing supplied with the Environmental Chamber. Please consult the instruction manual for each accessory to identify the appropriate vacuum connection port and fittings. 13

16 Vacuum Pump Kit For Use with the Atlas Evacuable Pellet Dies P/N GS03000 Series, Specadie P/N s GS03550/GS03700 and Atlas Lightweight Evacuable Pellet Dies P/N GS25410/GS25411 Fig 4 shows the small bore tubing assembly fitted with a barbed valve tap connection at one end (11) and open ended at the other (12) Fig 4. Small bore tubing and barbed valve tap connection that fits to the large bore tubing (10) The barbed valve tap connection (11) is directly connected by fitting into the open ended part of the large bore tubing (10) as shown at Fig 3. A stem elbow piece (13) is fitted into the open ended part of the small bore tubing (12). (See Fig 5). The elbow piece connector (13) is then used to attach to the 8mm O.D. ribbed vacuum pipe of the Evacuable Pellet Dies. Please consult the instruction manual for the Evacuable Pellet Dies to identify the vacuum pipe connection. 14

17 User Manual Note: The valve tap connection (11) is special in that it can be closed to stop the vacuum being pulled from the Evacuable Pellet Die through the large bore tubing whilst the vacuum pump is running, but in turn air is vented to the small bore tubing to allow for easier disconnection from the Pellet Die Fig 5. Complete assembly of large bore tubing connected to small bore tubing via valve tap with elbow piece connector (13) fitted for use with Atlas Evacuable Pellet Dies and Specadie For Use with the Cyclone and Tornado Gas Cells P/N s GS24102 and GS24205 Series Fig 4 shows the small bore tubing assembly fitted with a barbed valve tap connection at one end (11) and open ended at the other (12). The barbed valve tap connection (11) is directly connected by fitting into the open ended part of the large bore tubing (10). The small bore tubing open end (12) is then fitted directly to the 1/4 O.D. gas flow tube outlets of the Cyclone or Tornado long pathlength gas cells. Please consult the instruction manual for these gas cell types to identify the gas flow outlet tube connection. 15

18 Vacuum Pump Kit For Use with the Storm 10H Gas Cell GS05670 Fig 6 shows the large bore tubing and pressure gauge assembly (seen as Fig 3.) fitted with a barbed PEEK vacuum pipe adapter fitting with 1/8 BSP threading at its open end (14). This PEEK fitting with silicone gasket (15) is supplied with the GS05670 Storm 10H Gas Cell for connection to the tubing supplied with the GS03640 Vacuum Pump Kit. The PEEK fitting is screw fitted to the Swagelok fitting connections supplied for the valve port on GS The silicone gasket (15) is used to seal between the PEEK Valve fitting (14) and the Swagelok connection. Please consult the instruction manual for GS05670 to identify the outlet valve fitting connections Fig 6. T-Connector, Pressure Gauge and large bore tubing with PEEK vacuum pipe adapter fitting for GS05670 and GS

19 User Manual For Use with the High Temperature High Pressure Cell P/N s GS05850 and GS05855 Fig 7 shows the large bore tubing and pressure gauge assembly (seen as Fig 3.) fitted with a barbed PEEK vacuum pipe adapter fitting with 1/4 BSP threading at its open end (16). This PEEK fitting with silicone gasket (17) is supplied with both the GS05850 and GS05855 High Temperature High Pressure Cells for connection to the tubing supplied with the GS03640 Vacuum Pump Kit. The PEEK fitting is screw fitted to the Swagelok fitting connection supplied for the outlet gas port on GS05850 or GS The silicone gasket (17) is used to seal between the PEEK Valve fitting (16) and the Swagelok connection. Please consult the instruction manual for GS05850 to identify the outlet gas port fitting connections Fig 7. T-Connector, Pressure Gauge and large bore tubing with PEEK vacuum pipe adapter fitting for GS05850 and GS

20 Vacuum Pump Kit 6. Specifications for the Vacuum Pump Kit The Vacuum Pump GS03640 has the following specifications. No of stages: Two. Free Air Displacement: 85 liters/min at 220 volts operation. Ultimate vacuum: 15 microns. Pump motor: 0.25 HP. Pump speed: 2880 RPM (220Volts), 3440 RPM (110Volts). Electrical connectivity: 220Volts/50Hz, 110Volts/60Hz. Oil capacity: 260mls. Maximum operating temperature capability: 80 C. Minimum operating temperature capability: 1 C. Overall width (side to side dimension): 130mm (150mm to valve). Overall length (front to back dimension): 315mm. Overall height (to top of handle): 280mm. 18

21 User Manual 7. Spare Parts for the Vacuum Pump Kit P/N GS Vacuum Pump Oil (1 litre). 8. Vacuum Pump Kit Bubble Number Parts Identification List (1) Oil drain valve plug. (2) Oil filler cap. (3) Oil filling port. (4) Oil level sight glass. (5) Gas ballast valve. (6) Carry handle. (7) Inlet manifold valve handle. (8) Power on/off rocker switch. (9) Voltage selector slide switch. (10) Open end of large bore tubing. (11) Barbed valve on/off tap connector for tubing. (12) Open end of small bore tubing. (13) Elbow connector fitting for evacuable pellet dies. (14) 1/8 BSP threaded PEEK vacuum pipe adapter. (15) Silicon gasket for 1/8 BSP threaded PEEK vacuum pipe adapter. (16) 1/4 BSP threaded PEEK vacuum pipe adapter. (17) Silicone gasket for 1/4 BSP threaded PEEK vacuum pipe adapter. 19

22 Vacuum Pump Kit 20

23 Worldwide Distribution France Eurolabo - Paris. Tel Fax contact@eurolabo.fr Germany L.O.T. - Oriel GmbH & Co, KG - Darmstadt Tel: Fax: info@lot-oriel.de Website: Japan Systems Engineering Inc. -Tokyo Tel: Fax: systems-eng@systems-eng.co.jp Website: Spain Teknokroma S.Coop C. Ltda Barcelona Tel: Fax: comercial@teknokroma.es Switzerland Portmann InstrumentsAG Biel-Benken Tel: Fax: info@portmann-instruments.ch Website: USA SPECAC INC. 414 Commerce Drive Suite 175, Fort Washington, PA 19034, USA Tel: Fax: United Kingdom Specac Ltd. - London River House, 97 Cray Avenue, Orpington Kent BR5 4HE Tel: +44 (0) Fax: +44 (0) Registered No England

24 Brilliant Spectroscopy SPECAC INC. 414 Commerce Drive Suite 175, Fort Washington, PA 19034, USA Tel: Fax: SPECAC LTD. River House, 97 Cray Avenue, Orpington Kent BR5 4HE Tel: +44 (0) Fax: +44 (0) Registered No England

Atlas Lightweight Evacuable Pellet Dies User Manual

Atlas Lightweight Evacuable Pellet Dies User Manual Atlas Lightweight Evacuable Pellet Dies User Manual 2I-25410 Issue 2 Atlas Lightweight Evacuable Pellet Dies User Manual 2I-25410 Issue 2 User Manual Atlas Lightweight Evacuable Pellet Dies CONTENTS 1.

More information

Mini-Film Maker Kit User Manual

Mini-Film Maker Kit User Manual Mini-Film Maker Kit User Manual 2I-03970-7 Mini-Film Maker Kit User Manual 2I-03970-7 User Manual Mini-Film Maker Kit P/N GS03970 CONTENTS 1. INTRODUCTION... 3 2. CHECKLIST OF CONTENTS... 5 3. OPERATION

More information

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

Vacmobile 20/2. Instruction manual OPERATION & SERVICE This instruction manual provides general instructions for the Vacmobile 20/2 vacuum system. This machine may use either the Becker U4.20 or the PVR EM 20/B vacuum pump. Service information specific to

More information

Caresaver Universal Refrigerant Recovery Unit

Caresaver Universal Refrigerant Recovery Unit Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2

More information

model No: ir20.v2 FUSE

model No: ir20.v2 FUSE InstructioNS for: model No: ir20.v2 INFRARED PARAFfIN / KEROSENE / diesel HEATER 70000Btu 230V Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No: CLEAN WATER PUMP MODEL No: Hippo4A Part No: 7230535 OPERATION & MAINTENANCE INSTRUCTIONS 0807 INTRODUCTION Thank you for purchasing this CLARKE clean water pump. This highly efficient pump is designed

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP InstructioNS for: INFRARED PARAFfIN / KEROSENE / diesel HEATER model No: ir20.v2 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these

More information

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution. As a specialized enterprise in making vacuum pumps, we have devoted ourselves to satisfy our customers need for high quality products. We adopt the latest designs and technology to make sure that our products

More information

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515 OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515 Approval Agency s Model 2515B-75 Model 2515C-75 & 2515C-76 Warning Not recommended for pumping acid, base or organic vapors

More information

Variable Temperature Cell Holders User Manual

Variable Temperature Cell Holders User Manual Variable Temperature Cell Holders User Manual 2I-21525 Issue 17 Variable Temperature Cell Holders User Manual 2I-21525 Issue 17 User Manual Variable Temperature Cell Holders VARIABLE TEMPERATURE CELL

More information

Tempest TP550/206 Petrol Pressure Washer

Tempest TP550/206 Petrol Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

DUST EXTRACTOR MODEL No: CDE1000

DUST EXTRACTOR MODEL No: CDE1000 DUST EXTRACTOR MODEL No: CDE000 Part No:64765 OPERATING & MAINTENANCE INSTRUCTIONS GC054 INTRODUCTION Thank you for purchasing this CLARKE Dust Extractor which is intended to keep work areas free from

More information

CC Series VACUUM PUMPS

CC Series VACUUM PUMPS CC Series VACUUM PUMPS OPERATING MANUAL Thank you for selecting a Javac select product! Please read this operation manual carefully before use. Only suitably qualified personnel should operate this equipment.

More information

ASSEMBLY & OPERATING INSTRUCTIONS

ASSEMBLY & OPERATING INSTRUCTIONS SD-BASIC SPRAY DRYER ASSEMBLY & OPERATING INSTRUCTIONS 1) Introduction 2) Safety / COSHH 3) General Safety Rules 4) Components Included 5) Packing List 6) Connection to Electrical Supply 7) Assembly and

More information

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

More information

High Output Vacuum/Pressure Pump

High Output Vacuum/Pressure Pump High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz) Notice The information in this document is subject

More information

High Temperature High Pressure Cell User Manual

High Temperature High Pressure Cell User Manual High Temperature High Pressure Cell User Manual 2I-05850 Issue 16 High Temperature High Pressure Cell User Manual 2I-05850 Issue 16 User Manual High Temperature High Pressure Cell P/N GS05850 CONTENTS

More information

Vacuum Pump V-300 Operation Manual

Vacuum Pump V-300 Operation Manual Vacuum Pump V-300 Operation Manual 593756E en Imprint Product Identification: Operation Manual (Original) Vacuum Pump V-300 593756 Publication date: 07.206 BÜCHI Labortechnik AG Meierseggstrasse 40 Postfach

More information

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS ELECTRIC ASHCAN MODEL NO: ASHVAC1200 PART NO: 6471133 OPERATING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1216 INTRODUCTION Thank you for purchasing this CLARKE product which is designed for fast,

More information

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Owner s Manual Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Model AC375C Recover, Recycle, and Recharge Unit for R-12 or R-134a Refrigerant Voltage: 220 230; 50 60 Hz SAFETY DEFINITIONS:

More information

ZD-985 Desoldering Station

ZD-985 Desoldering Station ZD-985 Desoldering Station 2 Contents Contents... 3 Unpacking and Setting Up Your ZD-985 Desoldering Station... 4 Setting Up the Unit... 5 Auto Tip Saver Function... 8 Tips and Techniques... 8 Alloy Melt

More information

Laboport Chemically-resistant Laboratory Pumps and Systems

Laboport Chemically-resistant Laboratory Pumps and Systems Operating Instructions Read and observe these Operating Instructions! Laboport Chemically-resistant Laboratory Pumps and Systems N 810 FT.18 N 820 FT.18 N 840 FT.18 N 840.1.2 FT.18 N 810.3 FT.18 N 820.3

More information

Model No: Little Devil II (inc ss)

Model No: Little Devil II (inc ss) GAS HEATER Model No: Little Devil II (inc ss) PART NO: 6926020, 6926025 (SS) OPERATION & MAINTENANCE INSTRUCTIONS LS1213 INTRODUCTION Thank you for purchasing this CLARKE Gas Heater. Before attempting

More information

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700 A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,

More information

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap Instruction Manual A441-01-880 Issue F IT20K, IT100, IT300 and IT800 Inlet Traps Description ITO20K Inlet Catchpot ITC20K Inlet Chemical Trap ITD20K Inlet Desiccant Trap ITF20K Inlet Dust Filter ITO100

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96

More information

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0 Fisher Scientific Model 281A Vacuum Oven Installation and Operating Manual 30979 Rev. 0 Preface Models covered in this manual: Catalog numbers Models numbers Voltage 13-262-50 6288 120V 13-262-51 6289

More information

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING Water... 208 Gas... 210 Cassette Toilet... 211 207 WATER FAULTS Water Fault Cause Remedy Water not flowing from any tap when operated but pump runs Pump does not run Water flows from cold tap but not from

More information

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual (English) Table of Contents Page General Safety Instructions...2 System Overview...3 RecoverX-CAR Operation

More information

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap Instruction Manual A441-01-880 Issue G Original IT20K, IT100, IT300 and IT800 Inlet Traps idealvac.com (505)872-0037 idealvac.com Description ITO20K Inlet Catchpot ITC20K Inlet Chemical Trap ITD20K Inlet

More information

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual Recirculating Chiller RC350G-RC400G RC1400G-RC3000G Operating Manual Part No 09931/Issue 10 Page 2 April 2010 CONTENTS 1 Safety 4 2 Installation 5 2.1 Connection for closed loop circulation 6 2.2 Connection

More information

R100 Oil-Less Refrigerant Recovery Unit

R100 Oil-Less Refrigerant Recovery Unit R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE DIMENSIONS 150mm 55mm 200mm 67mm Hot water ¾ BSP Parallel Cold water ¾ BSP Parallel 160mm x 120mm aperture behind face plate for

More information

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH CAYENNE HEAT N SERVE 4/ RECTANGULAR RETHERMALIZER Item Description Voltage Watts Amps Plug 2050 T4R Countertop without Drain 120 1600 1. 5-15P 2051 TD4R Countertop with Drain 120 1600 1. 5-15P 2 T4R Countertop

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

Atlas High Temperature Film Maker Accessory User Manual

Atlas High Temperature Film Maker Accessory User Manual Atlas High Temperature Film Maker Accessory User Manual 2I-15800 Issue 15 Atlas High Temperature Film Maker Accessory User Manual 2I-15800 Issue 15 User Manual Atlas High Temperature Film Maker Accessory

More information

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation requirements. IMPORTANT: This Billi appliance is to be installed by a licensed trades person in accordance with AS/NZS

More information

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters  T (0) Installation & Operating Manual ZM-130 16 32kW Universal Oil Heater OVERVIEW Dfdfdfdsfd Dfdfffdfdf Dfdfdf 4 1. Overheat thermostat 2. Combustion chamber lid 3. Oil feed line 4. Activation thermostat 5.

More information

INSTRUCTION MANUAL Model: SU3022

INSTRUCTION MANUAL Model: SU3022 INSTRUCTION MANUAL Model: SU3022 GUARANTEE This product is guaranteed for 2 years from the date of original purchase. If any defect arises due to faulty materials or workmanship, the unit will, either

More information

infrared paraffin / kerosene / diesel heater

infrared paraffin / kerosene / diesel heater instructions for infrared paraffin / kerosene / diesel heater model no: IR20.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

More information

Magnetic Stirring Systems with Heat

Magnetic Stirring Systems with Heat Sharing your passion for making jewelry. Products. Service. Know-how. Magnetic Stirring Systems with Heat 335-212 Digital Ceramic Magnetic Stirring System with Heated Stand 335-211 Ceramic Magnetic Stirring

More information

WH-TD20B3E5 WH-TD30B3E5

WH-TD20B3E5 WH-TD30B3E5 Order No: PHAAM1004143C2 WH-TD20B3E5 WH-TD30B3E5 WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 5000W Ceiling/Wall Mounted Garage Heater OWNER S MANUAL Model: PH-950N IMPORTANT INSTRUCTIONS READ & SAVE PET OWNERS WARNING: The health of some small pets including birds are extremely sensitive to the

More information

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier Operating Manual Incl. EU Declaration of Conformity Vacuum Switch, Differential Pressure Adapter, Switching Amplifier VSC150, SV tina42e1-b (2017-03) 1 Product Identification In all communications with

More information

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. 6. Cooling System XCITING 400i Cooling System This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. Coolant... 6-3~6-11 Radiator... 6-12~6-23 Thermostat...

More information

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916 VACUUM EXTRACTOR MODEL NO: CWVE1 PART NO: 6471168 OPERATING & MAINTENANCE INSTRUCTIONS GC0916 INTRODUCTION Thank you for purchasing this CLARKE Workshop Vacuum Extractor. Before attempting to use this

More information

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO: WARNING: Do not use the machine without reading this manual POWER WASHER MODEL NO: JET 9000 PART NO: 7333502 OPERATION & MAINTENANCE INSTRUCTIONS GC0913 INTRODUCTION Thank you for purchasing this CLARKE

More information

SERVICE REQUIREMENTS

SERVICE REQUIREMENTS SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service WL270 Water Treatment System. Failure to follow the instructions in this manual could result in

More information

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581 OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581 Warning Not recommended for pumping acid, base or organic vapors or gases. Warning Be sure to properly identify intake and discharge before using pump. See

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY AGITATOR 20 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use

More information

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER 24 SAFETY AND OPERATING MANUAL Original instructions This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience

More information

Laboratory Freeze Dryer CRYODOS

Laboratory Freeze Dryer CRYODOS MAINTENANCE MANUAL Laboratory Freeze Dryer CRYODOS CRYODOS_I_rev005MA Telstar Industrial, S.L. Josep Tapiolas, 0 086 TERRASSA (Spain) Tel. +34 937 36 6 00 Fax: +34 937 85 93 4 telstar@etelstar.com www.etelstar.com

More information

ELECTRIC ASH CAN Model: CVACASH500 Part No:

ELECTRIC ASH CAN Model: CVACASH500 Part No: ELECTRIC ASH CAN Model: CVACASH500 Part No: 6471132 OPERATING & MAINTENANCE INSTRUCTIONS GC0614 INTRODUCTION Thank you for purchasing this electrically powered Ash Can which is designed for fast, easy

More information

JUNEAU JUN. 08/51193/0 Issue 0

JUNEAU JUN. 08/51193/0 Issue 0 JUNEAU JUN 08/51193/0 Issue 0 The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3 These cover

More information

ROTARY VACUUM EVAPORATOR RVO 004

ROTARY VACUUM EVAPORATOR RVO 004 INGOS Ltd. ROTARY VACUUM EVAPORATOR RVO 004 User manual PRAGUE April 11 2006 INGOS Ltd. Laboratory Instruments division Page 1 Producer : Laboratory Instruments division of INGOS Ltd. Supplier and service

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1500T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

FCHM Hydromatic Pump Control Module

FCHM Hydromatic Pump Control Module FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to

More information

PARAFFIN/DIESEL HEATER

PARAFFIN/DIESEL HEATER PARAFFIN/DIESEL HEATER MODEL NO: XR60 PART NO: 6931002 OPERATION & MAINTENANCE INSTRUCTIONS LS0813 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR. FOX Model F50-843

ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR. FOX Model F50-843 ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR FOX Model F50-843 1 3hp Dust Extractor FOX MODEL F50-843 TABLE OF CONTENTS Safety instructions Page 3 Specific safety instructions for dust collectors.page

More information

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY Pro-Set TR500 SERIES Oilless Refrigerant Recovery System OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR500, TR500E, TR500J, TR500S TO BE OPERATED

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

1. CONDITIONS FOR USE 2. SAFETY

1. CONDITIONS FOR USE 2. SAFETY 1. CONDITIONS FOR USE This micro abrasive blaster may only be operated: Indoors; Below 6500 ft above sea level altitude; Ambient air temperature between 40-105 F (5-40 C); Maximum relative humidity of

More information

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111 OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111 Contents: Safety Information Installation Operation Maintenance Trouble-Shooting Guide Specifications Warranty Parts List and Exploded View

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2 User Manual Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2 Warning: Not recommended for pumping acid, base, organic vapors or explosive gases. Be sure to properly

More information

OPERATION & MAINTENANCE MANUAL RHS680

OPERATION & MAINTENANCE MANUAL RHS680 OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup

More information

Aspirator with trap flask FTA-1

Aspirator with trap flask FTA-1 Aspirator with trap flask FTA-1 For version V.4GW Contents 1 Safety...3 2 General Information...5 3 Getting started...6 4 Operation...7 5 Specifications...9 6 Guarantee and service...10 7 Declaration

More information

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders Your Hoover Guarantee Contents Your Hoover Guarantee During year 1 HOOVER engineers will replace or repair all defective parts free of charge, except for parts subject to fair wear and tear such as belts,

More information

Sip Vacuum Cleaner 1400/35 Wet & Dry

Sip Vacuum Cleaner 1400/35 Wet & Dry Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 7,500W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL Model: DR-975 7500W 240V 60Hz IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions. 3 Installation Instructions...

More information

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual

More information

PARAFFIN/DIESEL HEATERS

PARAFFIN/DIESEL HEATERS PARAFFIN/DIESEL HEATERS Model Nos. XR75 - XR105 - XR 155 Part Nos. 6920270-6920280 - 6920290 1200 Thank you for purchasing this CLARKE, Paraffin fired Space Heater. This range of portable heaters is designed

More information

GAS HEATERS Models: Little Devil (inc ss), Devil 650/660(ss), Devil 850/860(ss), Devil 1250/1260(ss), Devil 1850, Devil 3000 & Devil 3150

GAS HEATERS Models: Little Devil (inc ss), Devil 650/660(ss), Devil 850/860(ss), Devil 1250/1260(ss), Devil 1850, Devil 3000 & Devil 3150 GAS HEATERS Models: Little Devil (inc ss), Devil 650/660(ss), Devil 850/860(ss), Devil 1250/1260(ss), Devil 1850, Devil 3000 & Devil 3150 OPERATING & MAINTENANCE INSTRUCTIONS GC0711 CONTENTS Guarantee...

More information

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P Salamander Heater OWNER S MANUAL Model:DR-PS11024 10KW 240V 60Hz 1P DR-PS11524 15KW 240V 60Hz 1P DR-PS31520 15KW 208V 60Hz 3P IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions...3-4

More information

diesel HEATERS Warning!

diesel HEATERS Warning! SPACE WARMER Paraffin / kerosene / diesel HEATERS Model no: AB708.V2, AB7081.V2 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

More information

LC Series - Light Commercial Pump Station Installation and Operation Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump

More information

Proline GAS HOB Model TCG40IX Instruction Book

Proline GAS HOB Model TCG40IX Instruction Book Proline GAS HOB Model TCG40IX Instruction Book GB Operating and Installation Instructions Index Technical data and specifications...... 3 Installation...................... 3-6 Ventilation........................

More information

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS Classification: Reference: Date: HA94-005 NTB94-091 September 26, 1994 SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS APPLIED VEHICLE(S): All models except Quest equipped with a retrofitted A/C system SERVICE

More information

MC2000 OPERATING AND CALIBRATION INSTRUCTIONS

MC2000 OPERATING AND CALIBRATION INSTRUCTIONS MC2000 OPERATING AND CALIBRATION INSTRUCTIONS CONTENTS 1 - CERTIFICATE OF CONFORMITY... 3 2 - PRESENTATION... 4 2. 1 - GENERAL... 4 2. 2 - CHARACTERISTICS... 4 2. 3 - OPERATING PRINCIPLE... 5 2. 3. 1 -

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax Part# 1000692 7/12/99 tn INSTRUCTIONS This manual contains important information concerning the installation and operation of the gun washers listed at the right. Read manual thoroughly and keep for future

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

Instruction Manual. B Issue B. next Pump Accessories

Instruction Manual. B Issue B. next Pump Accessories Instruction Manual B811-00-880 Issue B next Pump Accessories This page has been intentionally left blank. Contents Section Page 1 Introduction... 1 Contents gea/0086/06/10 1.1 Scope and definitions...

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

Tempest TP420/180 Electric Pressure Washer

Tempest TP420/180 Electric Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

INSTRUCTIONS FOR: SPACE WARMER PARAFFIN / KEROSENE / DIESEL HEATER MODEL NO: AB458.V3

INSTRUCTIONS FOR: SPACE WARMER PARAFFIN / KEROSENE / DIESEL HEATER MODEL NO: AB458.V3 INSTRUCTIONS FOR: SPACE WARMER PARAFFIN / KEROSENE / DIESEL HEATER MODEL NO: AB458.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to

More information

ORIGINAL INSTRUCTIONS

ORIGINAL INSTRUCTIONS WARNING: Read the instructions before using the machine. POWER WASHER MODEL NO: JETSTAR 1950 PART NO: 7336010 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0617 - ISS 3 INTRODUCTION Thank

More information

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Mobile Air Conditioner Instruction Manual Model TC-N9KM Mobile Air Conditioner Instruction Manual Model TC-N9KM Please read and retain these instructions for future reference SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air

More information

INSTRUCTIONS CertoClav EL

INSTRUCTIONS CertoClav EL High Pressure-LABORATORY AUTOCLAVE Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization As an aid in research and development Thermometer Lid handle with locking

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE WALL/CEILING MOUNT HEATER OWNER S MANUAL Model No.: DR-966 6000W 240V 60HZ IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions.. 3 Specifications and Wiring Diagram 5 Parts of

More information

hp Dust Collector With Vacuum Attachment

hp Dust Collector With Vacuum Attachment Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS WET & DRY GARAGE VAC 20L CAPACITY 1.5M SUCTION HOSE STAINLESS STEEL TANK ON BOARD ACCESSORY STORAGE 1250 WATT MOTOR KP702 Table of Contents 20L WET & DRY GARAGE VAC Know Your Product...1 Vacuum Safety

More information

Varsity Concealed Shower System

Varsity Concealed Shower System VARSITY CONCEALED SHOWER SYSTEM Installation & aftercare instructions Please retain for future reference Varsity Dual Function Concealed Shower System Product code SVA1615 Varsity Single Function Concealed

More information

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018 Installation and Operation Instructions Versa TM Screw Plug Oil & Water Immersion Heater 1 PD449-2 161-306451-003 January 2018 B 6" 1-13/16 Cold (Ref.) 9-1/8" 2-3/4 Min. Hole Size 6" 7-7/8" Thermowell

More information