Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

Size: px
Start display at page:

Download "Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006"

Transcription

1 Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A Mar. 03, American Standard inc. All Rights Reserved Pub. No

2 It's Hard to Stop a Trane. Single Package Cooling System Trane offers a complete family of cooling systems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. Introducing the new TRANE Single Package Cooling System. Single Package Cooling Systems are easy and versatile to install. Because cooling and air handlingfunctions are all contained in a single cabinet, a Trane package air conditioner is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermostat control and air distribution ducts, you have a highly efficient, total home comfort system. Single Package Cooling Systems provide better performance. Our single package air conditioners offer cooling efficiencies that are unmatched in the industry and provide you with a product far superior in performance than the competition. 2

3 Contents Optional Equipment Listing 4 General Data 5 Heater Data 8 SPEK Data 9 Performance Cooling Data 10 Typical Wiring 13 Optional Equipment 16 Dimensional Data 21 Mechanical Specifications 25 3

4 Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [ ] indicates accessories included) Roof Curb Full Perimeter (4TCC A) 3... BAYCURB050A[ ] Roof Curb Full Perimeter (4TCC A) 3... BAYCURB051A[ ] Roof Curb Utility Extension Kit (BAYCURB050A)... BAYUTIL101A[ ] Roof Curb Utility Extension Kit (BAYCURB051A)... BAYUTIL102A[ ] 0-25% Manual Fresh Air Damper (4TCC A) BAYOSAH001A[ ] 0-25% Manual Fresh Air Damper (4TCC A) BAYOSAH002A[ ] Motorized Fresh Air Damper (4TCC A) BAYDMPR101A[ ] Motorized Fresh Air Damper (4TCC A) BAYDMPR102A[ ] 16" Round Duct Adapter (2 per box) (4TCC A) 6... BAYSQRD001A[ ] 18" Round Duct Adapter (2 per box) (4TCC A) 6... BAYSQRD002A[ ] 0-100% Mod Economizer w/baro. Relief (4TCC A) BAYECON101B[ ] 0-100% Mod. Economizer w/baro. Relief (4TCC042-60A) BAYECON102B[ ] 0-100% Horizontal Economizer (4TCC A) BAYECON200A[ ] 0-100% Horizontal Economizer (4TCC A) BAYECON201A[ ] Enthalpy Control for Economizer (solid state).... BAYENTH001A[ ] Remote Potentiometer (All-BAYECON***A)... BAYSTAT023[ ] 1"-2" Filter Frame (4TCC A) (20 x 20 filter not included) BAYFLTR101A[ ] 1"-2" Filter Frame (4TCC A) (20 x 20,20X18 filter not included) BAYFLTR201A[ ] Evaporator Defrost Control (Low Ambient Cooling) Kit BAYLOAM011A[ ] Head Pressure Control (Low Ambient Cool) (208/240v) Kit BAYLOAM105A[ ] Quick Start Kit (4TCC3-A1)... BAYKSKT301A[ ] Crankcase Heater Recip (4TCC3018A1)(230v) BAYCCHT003A[ ] Crankcase Heater Scroll(4TCC3036,48,60A1/3)(230v) BAYCCHT202A[ ] Crankcase Heater (4TCC3036,48,60A4)(460v) BAYCCHT203A[ ] Adapter Curb 4TCC A to BAYCURB030,38... BAYADAP050A[ ] Adapter Curb 4TCC A to BAYCURB BAYADAP051A[ ] Adapter Curb 4TCC A to BAYCURB030,38... BAYADAP052A[ ] Adapter Curb 4TCC A to BAYCURB BAYADAP053A[ ] Adapter Curb 4TCC A to BAYCURB BAYADAP054A[ ] 12" Duct Shroud Covers Horizontal 4TCC A7.... BAYCOVR112A[ ] 18" Duct Shroud Covers Horizontal 4TCC A BAYCOVR118A[ ] Extreme Condition Mounting Kit - All BAYCURB & BAYADAP... BAYEXMK001A[ ] Extreme Condition Mounting Kit - All BAYUTIL... BAYEXMK002A[ ] Extreme Condition Mounting Kit - All Slab Mounts... BAYEXMK003A[ ] Lifting Lug Kit... BAYLlFT002B[ ] SUPPLEMENTARY HEATERS (1 PHASE) 3.76/5.0 KW Heater (208/240V 1PH) (4TCC A1)... BAYHTRV105A[ ] 7.50/10.0 KW Heater (208/240V 1PH) (4TCC A1)... BAYHTRV110A[ ] 11.27/15.00 KW Heater (208/240V 1PH) (4TCC A1)... BAYHTRV115A[ ] 15.0/20.0 KW Heater (208/240V 1PH) (4TCC A1)... BAYHTRV120A[ ] SUPPLEMENTARY HEATERS (3 PHASE) 3.76/5.0 KW Heater (208/240V 3PH) (4TCC A3)... BAYHTRV305A[ ] 7.50/10.0 KW Heater (208/240V 3PH) (4TCC A3)... BAYHTRV310A[ ] 11.27/15.00 KW Heater (208/240V 3PH) (4TCC A3)... BAYHTRV315A[ ] 15.00/20.0 KW Heater (208/240V 3PH) (4TCC A3)... BAYHTRV320A[ ] 3.76/5.0 KW Heater (460V 3PH) (4TCC A4)... BAYHTRV405A[ ] 7.50/10.0 KW Heater (460V 3PH) (4TCC A4)... BAYHTRV410A[ ] 11.27/15.00 KW Heater (460V 3PH) (4TCC A4)... BAYHTRV415A[ ] 15.00/20.0 KW Heater (460V 3PH) (4TCC A4)... BAYHTRV420A[ ] Single Power Entry Kit BAYSPEK060A[ ] Single Power Entry Kit BAYSPEK061A[ ] Single Power Entry Kit BAYSPEK062A[ ] Single Power Entry Kit BAYSPEK063A[ ] Single Power Entry Kit BAYSPEK064A[ ] Single Power Entry Kit BAYSPEK065A[ ] TES: 1 Must use internal filter frame when economizer or fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHT----A). 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications. 8 See table on page 8 for matching kit with units and heaters. 4

5 General Data MODEL RATED Volts/Ph/Hz RATINGS (COOLING) 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr)6 Sound Rating No. 2 POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity 3 Fuse Size Max. /Recmd.(Amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE No. Used/Dia. (in.) Type Drive/No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive / No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps L.R. Amps FILTER / FURNISHED? Type Recommended Min. Face Area 7(sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4TCC3018A1000A / / /1/ /38.6 SPINE FIN 2/ / /23 DIRECT/1 1/12/ /1/ / x 10 DIRECT/2 1/8/ /1/60 1/ (R-410A) X44.5X /348 4TCC3024A1000A / / /1/60 8.3/57.8 SPINE FIN 2/ / /23 DIRECT/1 1/12/ /1/ / x 10 DIRECT/2 1/4/ /1/60 1.4/ (R-410A) X44.5X /348 4TCC3030A1000A / / /72.5 SPINE-FIN 2/ / /23 DIRECT/1 1/5/ /1/60 1.1/ x 10 DIRECT/3 1/2/ /1/60 2/ (R-410A) X44.5X /349 4TCC3036A1000A / / /83 SPINE FIN 2/ / /23 DIRECT/1 0.2/ /1/60 1.1/ x 10 DIRECT/3 1/2/ /1/60 2.9/ (R-410A) X44.5X /364 4TCC3036A3000A /3/ / /3/ / /3/ /77 SPINE FIN 2/ / /23 DIRECT/1 1/5/ /1/60 1.1/ x 10 DIRECT/3 1/2/ /1/60 2.9/ (R-410A) X44.5X /354 1Rated in accordance with A.R.I. Standard 210/240. Noise tested in accordance with A.R.I. Standard 270. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are UL Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit. 5

6 General Data MODEL RATED Volts/Ph/Hz RATINGS (COOLING) 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr)6 Sound Rating No. 2 POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity 3 Fuse Size Max. /Recmd.(Amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE No. Used/Dia. (in.) Type Drive/No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive / No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps L.R. Amps FILTER / FURNISHED? Type Recommended Min. Face Area 7(sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4TCC3036A4000A 460/3/ / /3/ /15 460/3/ /35 SPINE FIN 2/ / /23 DIRECT/1 1/5/ /1/60 0.6/ x 10 DIRECT/2 1/2/ /1/60 1.7/ (R-410A) X44.5X /354 4TCC3042A1000A / / /104 SPINE FIN 2/ /15 5 1/27.6 DIRECT/1 1/4/ /1/60 1.4/ x 10 DIRECT/3 1/2/ /1/60 2.5/ (R-410A) X47.4X /395 4TCC3048A1000A / / /109 SPINE FIN 2/ /15 5 1/27.6 DIRECT/1 1/4/ /1/60 1.4/ x 10 DIRECT/3 3/4/ /1/60 4/ (R-410A) X47.4X /479 4TCC3048A3000A /3/ / /3/ / /3/ /91 SPINE FIN 2/ /15 5 1/27.6 DIRECT/1 1/4/ /1/60 1.4/ x 10 DIRECT/3 3/4/ /1/60 4/ (R-410A) X47.4X /479 4TCC3048A4000A 460/3/ / /3/ /15 460/3/ /46 SPINE FIN 2/ /15 5 1/27.6 DIRECT/1 1/4/ /1/ / x 10 DIRECT/2 3/4/ /1/60 2.2/ (R-410) X47.4X /479 1Rated in accordance with A.R.I. Standard 210/240. Noise tested in accordance with A.R.I. Standard 270. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are UL Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit. 6

7 MODEL RATED Volts/Ph/Hz RATINGS (COOLING) 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr)6 Sound Rating No. 2 POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity 3 Fuse Size Max. /Recmd.(Amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE No. Used/Dia. (in.) Type Drive/No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive / No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps L.R. Amps FILTER / FURNISHED? Type Recommended Min. Face Area 7(sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4TCC3060A1000A / / /158 SPINE FIN 2/ /15 5 1/27.6 DIRECT/1 1/4/ /1/60 1.4/ x 10 DIRECT/3 1/ / (R-410A) X47.4X /482 General Data 4TCC3060A3000A /3/ / /3/ / /3/ /137 SPINE FIN 2 / / / 27.6 DIRECT / 1 1/4 / /1/ / X 10 DIRECT/3 1 / / (R-410A) X 47.4 X / 482 4TCC3060A4000A 460/3/ / /3/ /25 460/3/ /62 SPINE FIN 2 / / / 27.6 DIRECT / 1 1/4 / /1/ / X 10 DIRECT/3 1 / / (R-410A) X 47.4 X / 482 1Rated in accordance with A.R.I. Standard 210/240. Noise tested in accordance with A.R.I. Standard 270. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are UL Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit. 7

8 Heater Data 4TCC3018A to 4TCC3060A Heater Data UNIT MODEL ELECTRIC HEATER MODEL RATED VOLTAGE PHASE AMPS HEATER CAPACITY. OF STAGES KW / STAGE KW BTUH 1 2 MCA (2) MAX. FUSE OR HQCR CKT BKR SIZE (4) CANADA ONLY MAX. CKT BKR SIZE (5) ^W/TC*3018A1 BAYHTRV105A 208/ / / / /5.0 23/26 25/30 25/30 ^W/TC*3024A1 ^W/TC*3030A1 ^W/TC*3036A1 ^W/TC*3042A1 ^W/TC*3048A1 ^W/TC*3060A1 ^W/TC*3036A3 ^W/TC*3048A3 ^W/TC*3060A3 ^W/TC*3036A4 ^W/TC*3048A4 ^W/TC*3060A4 BAYHTRV105A 208/ / / / /5.0 23/26 25/30 25/30 BAYHTRV110A 208/ / / / / /52 45/60 45/60 BAYHTRV105A 208/ / / / /5.0 23/26 25/30 25/30 BAYHTRV110A 208/ / / / / /52 45/60 45/60 BAYHTRV115A# 208/ / / / / /5.0 68/78 70/80 70/80 BAYHTRV105A 208/ / / / /5.0 23/26 25/30 25/30 BAYHTRV110A 208/ / / / / /52 45/60 45/60 BAYHTRV115A# 208/ / / / / /5.0 68/78 70/80 70/80 BAYHTRV120A# 208/ / / / / / /104 90/110 90/110 BAYHTRV305A 208/ / / / /5.0 13/15 15/15 15/15 BAYHTRV310A 208/ / / / / /30 30/30 30/30 BAYHTRV315A 208/ / / / / /5.0 39/45 40/45 40/45 BAYHTRV305A 208/ / / / /5.0 13/15 15/15 15/15 BAYHTRV310A 208/ / / / / /30 30/30 30/30 BAYHTRV315A 208/ / / / / /5.0 39/45 40/45 40/45 BAYHTRV320A 208/ / / / / / /60 60/60 60/60 BAYHTRV405A BAYHTRV410A BAYHTRV415A BAYHTRV405A BAYHTRV410A BAYHTRV415A BAYHTRV420A TES: 1. Any power supply and circuits must be wired and protected in accordance with local electrical codes. (2) The MCA values listed are for electric heater only. 3. Field wire must be rated at least 75 C (4) The HACR circuit breaker is for U.S.A. installations only. (5) For Canada installation reference only. * Heater uses fuses. 8

9 SPEK 4TCC3018A to 4TCC3060A Single Power Entry Kit Data SINGLE POWER ENTRY KIT BAYSPEK060 BAYSPEK061A BAYSPEK062A # SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION HEATER MODEL BAYHTRV105A BAYHTRV110A BAYHTRV305A BAYHTRV310A BAYHTRV315A BAYHTRV405A BAYHTRV410A BAYHTRV415A BAYHTRV420A UNIT MODEL MIN CKT AMP MAX OVER- CURRENT DEVICE 4TC*3018A SINGLE POWER ENTRY KIT HEATER MODEL UNIT MODEL MIN CKT AMP MAX OVER- CURRENT DEVICE 4TC*3030A TC*3024A TC*3036A TC*3030A BAYHTRV115A 4TC*3042A TC*3036A BAYSPEK063A # 4TC*3048A TC*3042A TC*3060A TC*3048A TC*3024A TC*3030A TC*3036A TC*3042A TC*3048A TC*3036A TC*3048A TC*3060A TC*3036A TC*3048A TC*3060A TC*3036A TC*3048A TC*3060A TC*3036A TC*3048A TC*3060A TC*3036A TC*3048A TC*3060A TC*3036A TC*3048A TC*3060A TC*3048A TC*3060A BAYHTRV105A 4TC*3060A BAYHTRV110A 4TC*3060A TC*3048A BAYHTRV120A 6 4TC*3060A TC*3048A BAYSPEK064A # BAYHTRV320A 6 4TC*3060A # Single Circuit Power fuses are supplied if required for unit and/or heater. From Dwg. 21C P01& 2 9

10 Performance Data Cooling 4TCC3018A AT 600 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 675 CFM COMPRESSOR POWER = 1183 WATTS I.D. FAN POWER = 236 WATTS O.D. FAN POWER = 217 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 4TCC3024A AT 800 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 725 CFM COMPRESSOR POWER = 1698 WATTS I.D. FAN POWER = 191 WATTS O.D. FAN POWER = 202 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 4TCC3030A AT 1000 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1000 CFM COMPRESSOR POWER = 1922 WATTS I.D. FAN POWER = 315 WATTS O.D. FAN POWER = 308 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 10

11 Performance Data Cooling 4TCC3036A AT 1200 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1200 CFM COMPRESSOR POWER = 2556 WATTS I.D. FAN POWER = 420 WATTS O.D. FAN POWER = 206 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 4TCC3042A AT 1400 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1450 CFM COMPRESSOR POWER = 3009 WATTS I.D. FAN POWER = 518 WATTS O.D. FAN POWER = 109 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 4TCC3048A AT 1600 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1600 CFM COMPRESSOR POWER = 3330 WATTS I.D. FAN POWER = 583 WATTS O.D. FAN POWER = 314 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 11

12 Performance Data Cooling 4TCC3060A AT 2000 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1800 CFM COMPRESSOR POWER = 4391 WATTS I.D. FAN POWER = 595 WATTS O.D. FAN POWER = 287 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 12

13 Typical Field Wiring UNIT CONTROL BOX UNIT HEATER AREA POLARIZED PLUG ELECTRIC HEATER CONTROL BOX UNIT LOW VOLTAGE AREA B G Y W1 W2 O T R COMMON FAN COMPRSSOR 1ST STAGE ELECTRIC HEAT 2ND STAGE ELECTRIC HEAT SWITCHOVER VALVE DEFROST CONTROL 'T' SIGNAL 24 VOLTS GROUND WIRE 1 PH POWER 1 PH POWER 3 PH 3 PH POWER POWER UNIT HEATER TE 1,8 UNIT CONTROL BOX TYPICAL THERMOSTAT FIG. 1 SINGLE POWER ENTRY ACCESSORY CONNECTIONS FIG. 2 ECOMIZER ACCESSORY CONNECTIONS TO COMPR. CONTACTOR UNIT HEATER AREA FACTORY PROVIDED FIELD CONNECTED WIRES ELECTRIC HEATER CONTROL BOX TO ECOMIZER FACTORY PROVIDED FIELD INSTALLED WIRES TE 9 (BL) (YL) (T APPLICABLE TO THE WCM---F MODELS) (BL) B 1 PH POWER 3 PH POWER SINGLE POWR ENTRY UNIT LOW VOLTAGE AREA GROUND WIRE SPE ACCESSORY KIT UNIT FUSES HEATER FUSES SEE SPEK INSTALLER'S GUIDE FOR ALL OTHER EXAMPLES UNIT LOW VOLTAGE AREA (GR) (PR) TYPICAL 2-STAGE THERMOSTAT (OR) (OR) (GR) G (YL) Y (WH) W1 (WH) W2 (OR) O (BR) T (RD) R FIG. 3 OUTDOOR THERMOSTAT ACCESSORY CONNECTIONS UNIT LOW VOLTAGE AREA HEATER SECOND STAGE AMBIENT TEMPERATURE LOCKOUT TE 7,8 (WH) W1 (WH) W2 UNIT LOW VOLTAGE AREA HEATER AMBIENT TEMPERATURE LOCKOUT TE 7,8 (WH) W1 (WH) W2 OUTDOOR THERMOSTAT ACCESSORY BAYSTAT033A TE 10 OUTDOOR THERMOSTAT ACCESSORY BAYSTAT033A TE 10 TYPICAL THERMOSTAT TYPICAL THERMOSTAT 13

14 Typical Wiring 14

15 Typical Wiring From Dwg. 21D P02 15

16 Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit A Economizer rain hood Mist eliminator Outside air dampers Return air dampers Required filter kit, order separately Economizer BAYECON101A BAYECON102A Unit ApplicationM odels 2/4YC,WC A 4TC* A 2/4YC,WC A 4TC* A A " " Relief damper Roofcurb Return Duct BAYCON200,201A Horizontal Economizer and Rain Hood Economizer A B C Gaskets (2) Duct Rain Hood Economizer Unit Application Models A B C BAYECON200AA BAYECON201AA 2/4YC,WC A 4TC* A 2/4YC,WC A 4TC* A 22.00" 20.00" 16.87" 24.00" 22.65" 19.00" 16

17 Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) A FULLY OPEN D C 2/3 1/3 B FULLY CLOSED Manual Fresh Air Model BAYOSAH001 BAYOSAH002 Unit Application Models 2/4YC,WC A 4TC* A 2/4YC,WC A 4TC* A A B C D 22 7/16" 20 11/16" 12 " 9 3/16" 25 3/16" 20 11/16" 12 " 9 3/16" BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) A C B E D BAYDMPR101A BAYDMPR102A Unit Application Models 2/4YC,WC A 4TC A 2/4YC,WC A 4TC A A B C D E 15 13/16" 11 13/16" 10 1/4" 11 1/2" 12 1/4" 18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4" 17

18 Optional Equipment BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR ***** A SUPPLY RETURN D A WOOD NAILER SUPPLY AIR C RETURN AIR B CHANNEL END CHANNEL SIDE HOLE IN ROOF SERVICE CLEARANCE DIMENSIONS A B C D 42" 36" 12"* 42" 22 *42 WITH ECOMIZER WITH 25% FRESH AIR ACCESSORY BAYCURB050A 18

19 Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for ***** A SUPPLY RETURN D A WOOD NAILER SUPPLY AIR C RETURN AIR B CHANNEL SIDE CHANNEL END HOLE IN ROOF SERVICE CLEARANCE DIMENSIONS A B C D 42" 36" 12"* 42" *42 WITH ECOMIZER WITH 25% FRESH AIR ACCESSORY BAYCURB051A 22 19

20 Optional Equipment BAYFLTR101, 201A, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) Filter 20

21 Dimensional Data and Weights RETURN SUPPLY Figure 1. TCC3018A through TCC3036A (1 of 2) 21

22 Dimensional Data and Weights SUPPLY RETURN [35-9/16] 36 [79] 36 [79] 57 [125] 57 [125] 40 [88] 40 [88] 36 [79] 57 [125] 40 [88] 36 [78] 56 [124] 41 [89] 36 [78] 56 [124] 41 [89] 36 [80] 58 [127] 42 [92] 37 [81] 58 [128] 41 [91] 38 [84] 61 [134] 43 [94] 25 [56] 158 [348] 25 [56] 158 [348] 25 [56] 158 [349] 26 [56] 161 [354] 26 [56] 158 [348] 26 [58] 162 [357] 26 [57] 162 [358] 27 [60] 169 [372] 635 [25.0] 508 [20.0] 635 [25.0] 508 [20.0] 635 [25.0] 508 [20.0] 635 [25.0] 508 [20.0] 635 [25.0] [20.3] 635 [25.0] [20.3] 635 [25.0] 508 [20.0] 635 [25.0] 508 [20.0] Figure 2. TCC3018A through TCC3036A (2 of 2) 22

23 Dimensional Data and Weights RETURN SUPPLY Figure 3. TCC3042A through TCC3060A (1 of 2) 23

24 Dimensional Data and Weights SUPPLY RETURN [37-9/16] [39-9/16] [37-9/16] [41-9/16] [39-9/16] 41 [90] 47 [105] 46 [102] 42 [92] 44 [98] 41 [90] 48 [105] 47 [104] 62 [137] 76 [168] 78 [172] 63 [138] 66 [146] 69 [152] 80 [177] 79 [175] 46 [102] 58 [127] 59 [130] 46 [102] 49 [109] 52 [115] 61 [134] 60 [132] 30 [67] 36 [79] 35 [77] 31 [69] 33 [73] 31 [68] 36 [79] 36 [76] 179 [395] [26.5] [24.8] 217 [479] [27.0] 635 [25.0] 219 [482] [27.5] 635 [25.0] 182 [401] [26.3] [24.8] 193 [425] [26.3] [24.8] 193 [425] [27.5] 635 [25.0] 225 [495] 222 [490] [27.5] [27.5] 635 [25.0] 635 [25.0] Figure 4. TCC3042A through TCC3060A (2 of 2) 24

25 Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with R-22. Units shall be UL listed and carry a UL label. All units shall be factory run tested to check cooling operation, fan and blower rotation and control sequence. Units shall be designed to operate at ambient temperatures between 115 F and 55 F in cooling as manufactured. Cooling performance shall be rated in accordance with ARI standards. Unit Casing All panels shall be heavy gauge steel, gasketed and insulated. Foil-faced fiber insulation shall be in the heater section. Foil-faced fiber nsulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARD exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Compressor The compressor shall be a hermetically sealed, high efficiency Climatuff compressor. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Other features include, roto lock suction and discharge refrigerant connections, centrifugal oil pump and low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports, and a refrigerant line filter shall be standard. Evaporator Coil Internally enhanced -inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have TXV to control refrigerant flow. Condenser Coil The Spine Fin condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Direct-drive, forward-curved, centrifugal wheel in a Composite Vortica Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Outdoor Fan One, direct-drive, statically and dynamically balanced propeller fan shall be used in a drawthrough vertical discharge configuration. Permanently lubricated weather proof motor shall have built-in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory-installed wood nailer strips. Electric Heaters Each heater assembly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Electric heat modules shall be UL listed. Single Source Power Entry This accessory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut-to-length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the downflow economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment off cycle. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit - Extra compressor starting capacity for single phase equipment. Control Options Standard Indoor Thermostats - Two stage heating/cooling or one stage heating/cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setback Thermostat - Programmable electronic thermostat shall provide heating setback and cooling setup with 7-day, programming capability. 1 H/1 C or 2H/2C models available. Trane 6200 Troup Highway Tyler, TX An American Standard Company American Standard has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 25

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08 Product Data 22-1782-05 4TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 2008 Trane Pub. No. 22-1782-05 07/08 Single Packaged Cooling System Trane offers a complete

More information

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A Product Data 22178001 2/4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ 5 Ton R22/R410A 2/4YCX3018A through 2/4YCX3060A Mar. 03, 2006 2006 American Standard inc. All Rights

More information

SEER 1½

SEER 1½ Product Data 22-1782-13 4TCC3018 through 4TCC3060 Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 2013 Trane Pub. No. 22-1782-13 07/13 It's Hard to Stop a Trane. Single Packaged Cooling System

More information

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ / YCC3048-SPEC-1B TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3048A107/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

4YCC3048A3096A /3/ /

4YCC3048A3096A /3/ / YCC3048A-SPEC-3A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS SPECIFICATIONS 4YCC3048A3075/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ / YCC30A-SPEC-1D TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING SPECIFICATIONS 2/4YCC30A1096/120A PRODUCT SPECIFICATIONS MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input

More information

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ / YCC3036A-SPEC-1E TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3036A1064/75/96A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No. Product Data 22-1789-06 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A 2007 Trane Pub. No. 22-1789-06 Single Packaged Electric Heat Pump System Trane offers a

More information

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No. Product Data 22179614 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2 5 Ton R410A 2013 Trane Pub. No. 22179614 It's Hard to Stop a Trane. Single Packaged Cooling System Trane offers

More information

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A Product Data 22-1807-09 4WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 06/14 2014 Trane Pub. No. 22-1807-09 It's Hard to Stop a Trane. Single Packaged Electric

More information

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014 Product Data Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton 4WCC4024A1000A 4WCC4030A1000A 4WCC4036A1000A 4WCC4042A1000A 4WCC4048A1000A 4WCC4060A1000A Note: Graphics in this document are for representation

More information

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A Product Data 22-1808-11 4YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, 75-120 MBTU R-410A 2011 Trane Pub. No. 22-1808-11 It's Hard to Stop a Trane. Single Packaged

More information

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG: 4YCC3060A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

4YCC3036A1075B /1/ / YCC3036A1064B /1/ / 4YCC3036A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A Product Data 4DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, 75-120 KBTU R-410A 2008 Trane Pub. No. Single Packaged Convertible Dual Fuel System Trane offers a complete

More information

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12 Product Data 22-1780-11 4WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12 2012 Trane Pub. No. 22-1780-11 It's Hard to Stop a Trane. Single Packaged Electric

More information

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG: Submittal Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified

More information

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A Product Data 22-1799-20-EN 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, 60-120 MBTU R-410A 2014Trane Pub. No. 22-1799-20-EN It's Hard to Stop a Trane. Packaged Convertible

More information

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A Product Data 4DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, 75-120 MBTU R-410A 2012 Trane Pub. No. It's Hard to Stop a Trane. Single Packaged Convertible Dual Fuel

More information

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG: Submittal Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A1060A SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data 2TTB0030-060A 2½ 5 Tons 22-1739-04 General Features Split System Cooling Units... The Evolution Continues 2TTB0 split systems represent a product that is

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data Three Phase 2TTA3048-060A3 4 5 Tons PUB. NO. 22-1770-03 Features and Benefits All aluminum Spine Fin coil Durable base, fast complete drain, weather proof

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-05 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A4018-24C/30-060B 2009 American Standard Heating & Air Conditioning PUB.. 12-1173-04 April 2009 Features and Benefits Duration compressor Efficiency

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

Split System Heat Pump Product & Performance Data

Split System Heat Pump Product & Performance Data SS-PRC007-EN Split System Heat Pump Product & Performance Data XL14i 2TWX4018-060 1½ 5 Tons PUB. NO. 22-1750-05 Features and Benefits Climatuff compressor Efficiency up to 15.25 SEER and 9.6 HSPF All aluminum

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-14-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 3 5 Tons PUB. NO. 22-1791-16-EN Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1842-07 Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin coil WeatherGuard fasteners

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-06 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG: Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEH3F18B1000A 2/4TEH3F24B1000A 2/4TEH3F30B1000A 2/4TEH3F36B1000A 2/4TEH3F42C1000A 2/4TEH3F48B1000A 2/4TEH3F60B1000A 1½ 5 Ton PUB. NO. 22-1777-10 Features and

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION Service Facts Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION 4TTB6-SF-3 UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED.

More information

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG: Submittal Split System Cooling 4A7A6024J1000B Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN Service Facts Split System Cooling 4TTB3030D1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8 Service Facts Split System Cooling 4TTR3060D1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Split System Cooling Product Data XB 1000

Split System Cooling Product Data XB 1000 Split System Cooling Product TTB-D-7 XB 1000 TTB012-060C PUB. NO. 22-1689-02-797 (EN) General Features Split System Cooling Units... Designed With Your Needs In Mind. TTB Split systems represent a new

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6048A1000A 4TTR6048A1000A 208/230/1/60 28 45 CLIMATUFF - SCROLL 1-2 208/230/1/60 21.2-104 PROPELLER 27.6-1 DIRECT - 1 4260 1-1/5 825 208/230/1/60 1.0 SPINE FIN 1-24

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6024A1000B 4TTR6024A1000B 208/230/1/60 18 20 CLIMATUFF - SCROLL 1-2 208/230/1/60 13.0-52 PROPELLER 27.6-1 DIRECT - 1 3200 1-1/8 835 208/230/1/60 0.74 SPINE FIN 1-24

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XB14 4TTB4 1 1 /2-5 Tons (018E - 061E) PUB. NO. 22-1833-08 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG: Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG: Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Product Data. Split System Cooling A. November 2013

Product Data. Split System Cooling A. November 2013 Product Data Split System Cooling 4TTR3018G1000A 4TTR3024G1000A 4TTR3030G1000A 4TTR3036E1000A 4TTR3042D1000A 4TTR3048D1000A 4TTR3060D1000A November 2013 22-1842-8A Product Specifications Model No. (a)

More information

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ Cooling/Heat Pump Convertible Air Handlers 2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ 5 Ton Preliminary PUB. NO. 22-1777-04 Features and

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT Service Facts Split System Cooling 4TTR6036B1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG: Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XB14 4TTB4 1 1 / 2-5 Tons (018E - 061E) PUB. NO. 22-1833-10 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL20i 4TTZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1825-08 Features and Benefits Two CLIMATUFF compressors deliver 50% and

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

AMERICAN STANDARD 14 MODELS 4A7B E

AMERICAN STANDARD 14 MODELS 4A7B E SPLIT SYSTEM COOLING 1 1 / 2 5 ton AMERICAN STANDARD 14 MODELS 4A7B4018-60E PUB. NO. 12-1290-02 June 2009 Features and Benefits DURaTION compressor Efficiency up to 16.0 SEER All aluminum Spine Fin coil

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES Service Facts Split System Cooling 4TTB18E1000A, 4TTB24E1000A 4TTBD1000B, 4TTB36D1000B 4TTB3-SF-1B CAUTION UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XL 15i 4TWX5018 42A, 049E, 061E 1½ 5 Tons PUB. NO. 22-1800-07 Features and Benefits Climatuff compressor Efficiency up to 16.00 SEER and 9.0 HSPF All aluminum Spine Fin coil

More information

Hyperion TM Split Systems

Hyperion TM Split Systems Hyperion TM Split Systems Split Systems Air Conditioning (Ducted Type) 3.0-5.0 Tons - R410a - 50Hz Indoor Units GAF2A0A36S3ASA GAT2A0C48S4ASA GAT2A0C60S5ASA GAM2A0C48S4ASB GAM2A0C60S5ASB Outdoor Units

More information

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/ Service Facts Split System Heat Pump 4TWB4024E1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Heat Pump D-EN. February 2016 Product Data Split System Heat Pump 4A6H6018H1000A 4A6H6024H1000A 4A6H6030H1000A 4A6H6036H1000A 4A6H6042H1000A 4A6H6048H1000A 4A6H6060H1000A Note: Graphics in this document are for representation only.

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL18i 4TTX8024, 036, 048 & 060 2, 3, 4 & 5 Tons PUB. NO. 22-1885-02 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information