1 Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump

2 Contents Product Features Product Options Air-Cooled Physical Data Water-Cooled Physical Data Air-Cooled Performance Data (a) (b) Air Source Heat Pump Unit Performance Data (a) (b).. 7 Water-Cooled Performance Data (a) (c) (d) (e) Water Source Heat Pump Performance Data (a) (c) (d) (e) Blower Performance Data (a) (b) (c) Evaporator Condenser Hot Water Coil Performance (a) (b) (c) (d) (e) (f) Chilled Water Coil Performance (a) (b) (c) (e) (f) Steam Coil Performance (a) (b) (c) (d) Electrical Data Electrical Data Electrical Data Compressor RLA Electrical Data: Evaporator Motor FLA: Condenser Motor FLA: Electrical Data Electric Heat FLA: (Heaters nominally rated at 220 or 460 volts.) Humidifier FLA: Electrical Data - Air-Cooled (c) (d) (e) Electrical Data - Air-Cooled (c) (d) (e) Electrical Data - Air-Cooled (c) (d) (e) Electrical Data - Air-Cooled (c) (d) (e) Electrical Data - Air-Cooled (c) (d) (e) Electrical Data - Air-Cooled (c) (d) (e) Electrical Data - Air-Cooled (c) (d) (e) Electrical Data - Water-Cooled (c) (d) (e) Electrical Data - Water-Cooled (c) (d) (e) Electrical Data - Water-Cooled (c) (d) (e) Electrical Data - Water-Cooled (c) (d) (e) Electrical Data - Water-Cooled (c) (d) (e) Electrical Data - Water-Cooled (c) (d) (e) Electrical Data - Water-Cooled (c) (d) (e) Electrical Data - Evaporator Section (c) (d) (e) Electrical Data - Evaporator Section (c) (d) (e) Electrical Data - Evaporator Section (c) (d) (e) Electrical Data - Evaporator Section (c) (d) (e) Electrical Data - Evaporator Section (c) (d) (e) Electrical Data - Evaporator Section (c) (d) (e) Electrical Data - Evaporator Section (c) (d) (e) Electrical Data - Air-Cooled Condensing Section (a) (b) (c) Electrical Data - Air-Cooled Condensing Section (a) (b) (c) Electrical Data - Air-Cooled Condenser (a) (b) (c) Electrical Data - Water-Cooled Condensing Section (a) (b) (c) Water-Cooled Piping Arrangements Water-Cooled Piping Arrangements Water-Cooled Piping Arrangements Basic Model Configurations Basic Model Configurations Basic Unit Dimensions Service Clearance - Plan View Miscellaneous Technical Data Options BASIC MODEL DESIGNATION Subject to change without notice. 2

3 Product Features The of units are unique in that they can be applied as close coupled or split with the evaporator remote from the condensing section. They are available as aircooled, water-cooled or heat pump configurations. The units can be ceiling or slab mounted. Additionally the units can be tailored for a specific application as a made to order unit. Individual sections can be used with other product series. Air-Cooled, Water-Cooled or Heat Pump Configurations R-410A Refrigerant Ceiling Mounted or Slab Mounted Package 2 & 3-Ton Unit Height of 23-1/8" (Includes the mounting rails) 4 & 5-Ton Unit Height of 26-1/8" (Includes the mounting rails) 6, 8 & 10 - Ton Unit Height of 33-1/8" (Includes the mounting rails) Cabinets Constructed of Scratch Resistant Heavy Duty 18 Gauge Galvanized Steel Splitable using Resealable Refrigerant Fittings Can locate sections with up to 100 equivalent lengths of refrigerant tubing (Contact the factory for specific details and for lengths more than noted above) Completely Serviceable at Ceiling Access From Both Sides of Unit Saves Valuable Floor Space when Ceiling Mounted Functionally Run Tested at the Factory (Limited Testing done when only one section ordered) 1/2" Fiber Glass Lined Cabinet (Thermal/Acoustical, min. density of 2 Pounds) 3/4" Drain Connections on Both Evaporator and Condensing Sections 304 Stainless Steel Double Sloped Drain Pan in Evaporator Section 1" ESP Capability (Contact factory with specific requirements, may require motor / drive upgrade) Belt Driven Blowers Ball Bearing Motors Resiliently Mounted Ball Bearings for Blowers Cast Iron Pulleys and Sheaves Inherently Protected Motors and Compressors Premium Efficiency Motors Adjustable Motor Mounts High and Low Refrigerant Pressure Safeties Loss of Air Safety Switch (when electric heat used) Individual Contactor for each Motor and Compressor Individual Contactor for Each Stage of Electric Heat Adjustable Expansion Valve with External Equalizer Sight Glass / Moisture Indicators Filter Driers 2" Pleated Filters Draw Through Air Flow Dual Electrical Control Boxes High and Low Side Schrader Valve Refrigerant Access Fittings Co-axial Counterflow Heat Exchanger on Water-Cooled Units Subject to change without notice. 3

4 Product Options Options (Items in BOLD are factory installed): Electric Heat or Reheat Protective Coil Coatings Steam Canister Humidifier SCR Controllers Vertical Stacking Unit Configuration Steam Coils Air or Water Side Economizer Hot Water Coils Drain Pan Overflow Switch Double Wall Construction Stainless Steel Cabinets Condenser Drain Pan 2-Way, 3-Way and / or 350 psig Water Regulating Valves (Mechanical or Electronic) Hot Gas Bypass w/ Manual Shut Off Valve Hot Gas Reheat Modulating Hot Gas Bypass Low Ambient Controls (Flooded Condenser or VFD) Freezestat Mixing Box Phase Protection Microprocessor Controls Copper / Copper Coils (Contact Factory) Coated Cabinets (Contact Factory) Non-Fused Disconnects Variable Frequency Drive (VFD) (Evaporator or Low Ambient) Thermostats Condensate Pump (shipped loose) CONTACT THE FACTORY FOR OTHER OPTIONAL FEATURES. Subject to change without notice. 4

5 Air-Cooled Physical Data Evaporator Supply Air CFM Evaporator Blower Size Qty 1 Evaporator Motors (a) Std. 0.25" ESP 1/3 1/2 3/4 1-1/2 Opt. 1.0" ESP 1/3 (c) 1/2 3/ /2 2 Rows Evaporator Coil Face Area FPI 12 Type Pleated Throwaway Filter Qty Dimensions 25 x 20 x 2 20 x 16 x 2 Efficiency MERV 8 Compressor Type Scroll Qty 1 2 Condenser Air CFM Condenser Blower Size Qty 1 Condenser Motors (a) Std. 0.25" ESP 1/2 3/4 1-1/ /2 Opt. 1.0" ESP 3/ /2 1-1/2 (c) 2 3 (c) 2 Rows 4 5 Condenser Coil Face Area FPI Charge R-410A (Lbs-Ozs) (Charge per circuit) (d) Weight (Net Operating) (b) Available Voltages Air-Cooled Air Source Heat Pump Air-Cooled Air Source Heat Pump / n/a n/a n/a 208/ (a) Certain options may affect motor size. Run unit in UCA Select for proper motor HP. (b) Net operating weight is for basic unit only. Options will add weight. (c) Pulley & Belt upgrade only. (d) R-410A Refrigerant charge is for base unit configuration. Addition of some options may alter refrigerant amount. Subject to change without notice. 5

6 Water-Cooled Physical Data Evaporator Supply Air CFM Evaporator Blower Size Qty 1 Evaporator Motors (d) Std. 0.25" ESP 1/3 1/2 3/4 1-1/5 Opt. 1.0" ESP 1/3 (c) 1/2 3/ /2 2 Rows Evaporator Coil Face Area FPI 12 Type Pleated Throwaway Filter Qty Dimensions 25 x 20 x 2 20 x 16 x 2 Efficiency MERV 8 Compressor Type Scroll Qty 1 2 Water-Cooled Condenser Type Co-Axial Qty 1 2 Charge R-410A (Lbs-Ozs) (Charge per circuit) (d) Weight (Net Operating) (b) Available Voltages Water-Cooled Water Source Heat Pump Water-Cooled Water Source Heat Pump / n/a n/a n/a 208/ (a) Certain options may affect motor size. Run unit in UCA Select for proper motor HP. (b) Net operating weight is for basic unit only. Options will add weight. (c) Pulley & Belt upgrade only. (d) R-410A Refrigerant charge is for base unit configuration. Addition of some options may alter refrigerant amount. Subject to change without notice. 6

7 Air-Cooled Performance Data (a) (b) (c) CFM Entering Air Temp. ( F) Air Over Condenser ( F) DB WB Total Sensible Total Sensible Total Sensible ,700 18,300 24,100 17,200 21,400 15, ,500 18,300 22,300 17,000 19,900 15, ,300 18,100 21,400 16,700 19,200 15, ,500 28,000 36,400 26,300 32,400 24, ,500 27,800 33,900 26,100 30,100 24, ,900 27,400 32,500 25,700 28,900 23, ,800 36,300 45,900 34,100 40,900 32, ,200 35,900 42,500 33,700 38,200 31, ,300 35,200 40,700 33,100 36,800 30, ,800 44,400 58,300 41,800 51,600 39, ,900 44,000 54,400 41,600 47,800 38, ,100 43,300 52,200 41,100 45,800 38, ,500 57,900 75,300 54,600 66,400 51, ,500 57,600 70,000 54,300 61,900 50, ,100 56,700 67,000 53,300 59,300 49, ,200 69,900 89,300 66,300 80,000 62, ,700 69,500 82,900 65,600 74,000 61, ,700 68,600 79,300 64,500 70,600 60, ,600 94, ,200 89, ,400 84, ,800 93, ,400 88, , ,200 91, ,200 86,800 90,800 81,400 Air Source Heat Pump Unit Performance Data (a) (b) (c) (a) Capacities are gross values, not adjusted for motor heat. (b) Some refrigerant circuit components may impact on unit capacities. (c) Supplemental heat is recommended with all heat pump configurations. Return Air Temp DB Outdoor Entering Air Temperature 47 / / ,560 14, ,320 15, ,540 21, ,390 22, ,730 25, ,430 27, ,460 35, ,060 37, ,285 41, ,655 43, ,340 52, ,565 55, ,400 70, ,000 73,400 Subject to change without notice. 7

8 Water-Cooled Performance Data (a) (c) (d) (e) GPM CFM Entering Air Temp. ( F) Entering Water Temperature ( F) DB WB Total Sensible Total Sensible Total Sensible ,300 17,900 24,700 17,700 24,100 17, ,400 17,700 22,900 17,400 22,300 17, ,500 17,400 21,900 17,100 21,400 16, ,700 27,200 37,700 26,800 36,800 26, ,600 26,900 34,700 26,500 33,800 26, ,000 26,500 33,200 26,000 32,300 25, ,200 35,300 48,000 34,700 46,800 34, ,500 35,200 44,400 34,700 43,300 34, ,500 34,900 42,400 34,300 41,400 33, ,000 44,000 61,400 43,300 59,800 42, ,100 43,500 56,700 42,900 55,300 42, ,600 42,700 54,200 42,100 52,900 41, ,000 56,300 77,900 55,500 75,900 54, ,900 55,700 72,100 54,800 70,300 54, ,800 55,000 69,100 54,100 67,400 53, ,300 69,100 93,700 68,100 91,100 67, ,400 68,500 87,000 67,500 84,700 66, ,600 67,600 83,300 66,500 81,100 65, ,600 95, ,400 94, ,200 93, ,800 94, ,000 92, ,000 91, ,600 92, ,800 91, ,000 90,000 Water Source Heat Pump Performance Data (a) (c) (d) (e) Return Air Temp. DB 70 F Entering Water Temp. Heating 70 28, , , , , , , , , , , , , ,600 GPM Pressure Drop PSI (b) CFM ea ea ea (a) Capacities are gross values, not adjusted for motor heat. (b) Pressure drop is for heat exchanger only and does not include piping, valves, fittings, etc. (c) Some refrigerant circuit components may impact on unit capacities. (d) Applications with water conditions 75 F and lower may require additional refrigerant circuit components. (e) Consult factory for details. (f) Contact factory for geothermal applications. Subject to change without notice. 8

9 Evaporator Blower Performance Data (a) (b) (c) Blower performance of basic unit with 2, MERV 8 pleated filter and wet coil 80 / 67 / 95 Standard Air Path Configuration Non-standard drive set or motor. Contact factory. Condenser External Static Pressure (ESP) CFM RPM BHP HP RPM BHP HP RPM BHP HP RPM BHP HP / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / Basic unit at 95 outdoor ambient. Standard Air Path Configuration External Static Pressure (ESP) CFM RPM BHP HP RPM BHP HP RPM BHP HP RPM BHP HP / / / / / / / / / / / / / / / / (a) Contact factory for values outside the data. (b) Blower performance of basic unit with standard filter and wet coil 80 / 67. (c) Performance with nominal CFM. For other CFM or ESP contact the factory for your specific application. Subject to change without notice. 9

10 Hot Water Coil Performance (a) (b) (c) (d) (e) (f) CFM GPM PD Ft. H2O Capacity (MBH) (a) Hot Water Coil Valves are optional. (b) Valves are spring return, On / Off operation only. (c) Entering water at 180 F. Leaving water at approximately 160 F. (d) Entering air temperature 65 F. (e) For other operating conditions or fluid type, contact the factory for performance. (f) Hot Water Coil Valve Sizes: Valve Size 2 3/4" 3 3/4" 4 3/4" 5 3/4" 6 1" 8 1" /4" Subject to change without notice. 10

11 Chilled Water Coil Performance (a) (b) (c) (e) (f) CFM GPM PD Ft. H2O Total (MBH) Sensible (MBH) (a) Capacity based on 80 F DB / 67 F WB with 45 F EFT. (b) Chilled water entering at 45 F. (c) For other operating conditions or fluid type, contact the factory for performance. (d) Chilled Water Coil Valves are optional. (e) Valves are spring return, On / Off operation only. (f) Chilled Water Coil Valve Sizes: Valve Size 2 3/4" 3 3/4" 4 3/4" 5 3/4" 6 1" 8 1" /4 Steam Coil Performance (a) (b) (c) (d) CFM 2 psi Capacity (MBH) Condensate (lb. / hr.) LAT (a) Low pressure, less than 10 psig. (b) Entering air at 65 F. (c) For other operating pressures, air flows and entering air conditions contact factory. (d) Steam valves and components by others, field installed. Subject to change without notice. 11

12 Electrical Data The following sections provide the formulas and the data to calculate the Minimum Circuit Ampacity (MCA) and the Maximum Overcurrent Protection (MOP) for your specific unit configuration. There are a variety of unit configurations. Please make sure to use the correct formulas per your configuration. Examples have also been provided for each configuration. RLA = Compressor Rated Load Amps FLA = Full Load Amps (Used for Blower Motors and Electric Heaters) MCA = Minimum Circuit Ampacity (Calculated value) MOP = Maximum Fuse Size (Calculated value) Cooling Only: Close Coupled Unit (Can be single or dual compressor) NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Evaporator Only Section MCA = (1.25 x Evap. Blower Motor Amps) MOP = (2.25 x Evap. Blower Motor Amps) Examples Cooling Only: It must be noted that the formulas refer to the largest motor amps. This typically is the compressor (RLA), but it can also be one of the blower motors (FLA). The data provided will cover the majority of available unit configurations. However, it should be noted that additional combinations may be available and the factory can be contacted for this data. Close Coupled Unit (Can be single or dual compressor) NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Single Compressor RLA = 7.8 Dual Compressors RLA = 10.4 each Evap. Blower Motor FLA = 1.3 Evap. Blower Motor FLA = 1.8 Cond. Blower Motor FLA = 1.3 Cond. Blower Motor FLA = 6 MCA = (1.25 x 7.8) = 12.4 MCA = (1.25 x 10.4) = 31.2 MOP = (2.25 x 7.8) = 20 MOP = (2.25 x 10.4) = 45 Rounded down to 40 Evaporator Only Section MCA = (1.25 x Evap. Blower Motor Amps) MOP = (2.25 x Evap. Blower Motor Amps) Evap. Blower Motor FLA = 3.2 MCA = (1.25 x 3.2) = 4.0 MOP = (2.25 x 3.2) = 7.2 Rounded to 10 Subject to change without notice. 12

13 Electrical Data Cooling with Electric Heat: Close Coupled Unit (Can be single or dual compressor) NOTE: Largest motor amps may not always be the compressor. Electric Heat On equipment with multiple modes of operation (i.e. cooling or heating), each mode shall be evaluated and whichever load condition provides the highest value shall be used. Use the larger of the following: MCA = (1.25 x largest motor amps) + the sum of the remaining motors or MCA = (Heater FLA + Evap. Motor FLA) x 1.25 MOP = (2.25 x largest motor amps) + the sum of the remaining motors or Evaporator Only Section Electric Heat MOP = (Evap. Blower Motor x 2.25) + Heater Amps MCA = (Heater FLA + Evap. Motor FLA) x 1.25 MOP = (Evap. Blower Motor x 2.25) + Heater Amps Examples Cooling with Electric Heat: Close Coupled Unit NOTE: Largest motor amps may not always be the compressor. Electric Heat Use the larger of the following: MCA = (1.25 x 26.4) = 41.4 or MCA = ( ) x 1.25 = 50.4 Use this value MOP = (2.25 x 26.4) = 67.8 Use this value Rounded to 70 or MOP = (4.2 x 2.25) = 45.6 Evaporator Only Section Electric Heat MCA = ( ) x 1.25 = 50.4 MOP = (4.2 x 2.25) = 45.6 MOP can t be lower than MCA Rounded Up to 55 Subject to change without notice. 13

14 Electrical Data Compressor RLA Electrical Data: Compressor (Qty) 208/ / ea. 6.4 ea ea. 7.7 ea ea. 8.6 ea. Evaporator Motor FLA: HP Used In 208/ / /3 2, 3, /2 3, 4, 5, /4 2, 3, 4, 5, 6, , 4, 5, 6, /2 4, 5, 6, 8, , 8, Condenser Motor FLA: HP Used In 208/ / / /2 2, /4 2, 3, , 4, /2 2, 3, 4, 5, 6, 8, , 4, 5, 6, 8, , , Subject to change without notice. 14

15 Electrical Data Electric Heat FLA: (Heaters nominally rated at 220 or 460 volts.) Nom. kw Used In , 3, , 4, 5, 6, , 5, 6, , NOTE: Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Humidifier FLA: Used In Unit Voltage Lbs. / Hr Amps Amps Amps / or / or CAUTION: HUMIDIFIER SHOULD NOT BE LOCATED IN SPACE SUBJECT TO FREEZING TEMPERATURES Water Supply Connection: (1) A 1/4" flare fitting is provided on an exterior panel. (2) Run a 1/2" water line to within 1 foot of the unit before reducing to 1/4" OD for the connector. Water Quality: (a) Inlet water pressure must be between 15 and 150 psi. If higher than 150 psi, install a regulator. (b) Use only potable water. (c) Water conductivity should be between 125 and 1,250 Micromhos (optimum is 150 to 350 Micromhos). (d) If water conductivity is over 250 Micromhos, do not use softened water. (e) De-mineralized water cannot be used, as there are no minerals to conduct the electricity. (f) Water ph range of 6.5 to 7.5. Cylinder Life: The normal life expectancy of a steam cylinder ranges from 500 to 4,000 hours, dependent upon the water quality and the use profile. Generally it can be expected to be around 2,000 hours. Subject to change without notice. 15

16 Electrical Data - Air-Cooled (c) (d) (e) 2 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Condenser Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA HP FLA KW Amps Used As Amps MCA MOP 1/ / / / / / Heat / / Heat / / Heat / / Heat / / Reheat / / Reheat / / Reheat / / Reheat / / / / / / Heat / / Heat / / Heat / / Heat / / Reheat / / Reheat / / Reheat / / Reheat / / / / / / Heat / / Heat / / Heat / / Heat / / Reheat / / Reheat / / Reheat / / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized and actual voltage applied. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 16

17 Electrical Data - Air-Cooled (c) (d) (e) 3 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Condenser Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA HP FLA KW Amps Used As Amps MCA MOP 1/ / / / / Heat / / Heat / Heat / Heat / / Reheat / / Reheat / Reheat / Reheat / / / / / Heat / / Heat / Heat / Heat / / Reheat / / Reheat / Reheat / Reheat / / / / / Heat / / Heat / Heat / Heat / / Reheat / / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized and actual voltage applied. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 17

18 Electrical Data - Air-Cooled (c) (d) (e) 4 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Condenser Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA HP FLA KW Amps Used As Amps MCA MOP 1/ / / / / / Heat / / Heat / / Heat / / Heat / / Reheat / / Reheat / / Reheat / / Reheat / / / / / / Heat / / Heat / / Heat / / Heat / / Reheat / / Reheat / / Reheat / / Reheat / / / / / / Heat / / Heat / / Heat / / Heat / / Reheat / / Reheat / / Reheat / / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 18

19 Electrical Data - Air-Cooled (c) (d) (e) 5 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Condenser Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA HP FLA KW Amps Used As Amps MCA MOP 1/ / / / / Heat / / Heat / Heat / Heat / / Reheat / / Reheat / Reheat / Reheat / / / / / Heat / / Heat / Heat / Heat / / Reheat / / Reheat / Reheat / Reheat / / / / / Heat / / Heat / Heat / Heat / / Reheat / / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 19

20 Electrical Data - Air-Cooled (c) (d) (e) 6 Ton Dual Circuit Voltage Compressor RLA 208/ ea ea. Evaporator Motor Condenser Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA HP FLA KW Amps Used As Amps MCA MOP 1/ / / / Heat / / Heat Heat Heat / / Reheat / / Reheat Reheat Reheat / / / / Heat / / Heat Heat Heat / / Reheat / / Reheat Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 20

21 Electrical Data - Air-Cooled (c) (d) (e) 8 Ton Dual Circuit Voltage Compressor RLA 208/ ea ea. Evaporator Motor Condenser Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA HP FLA KW Amps Used As Amps MCA MOP 3/ / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 21

22 Electrical Data - Air-Cooled (c) (d) (e) 10 Ton Dual Circuit Voltage Compressor RLA 208/ ea ea. Evaporator Motor Condenser Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA HP FLA KW Amps Used As Amps MCA MOP 1-1/ / / / Heat / / Heat Heat Heat / / Reheat / / Reheat Reheat Reheat / / / / Heat / / Heat Heat Heat / / Reheat / / Reheat Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 22

23 Electrical Data - Water-Cooled (c) (d) (e) 2 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / Heat / Heat / Reheat / Reheat / / Heat / Heat / Reheat / Reheat / / Heat / Heat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 23

24 Electrical Data - Water-Cooled (c) (d) (e) 3 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 24

25 Electrical Data - Water-Cooled (c) (d) (e) 4 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 25

26 Electrical Data - Water-Cooled (c) (d) (e) 5 Ton Single Circuit Voltage Compressor RLA 208/ / Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat / / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat / / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 26

27 Electrical Data - Water-Cooled (c) (d) (e) 6 Ton Dual Circuit Voltage Compressor RLA 208/ ea ea. Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat / / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 27

28 Electrical Data - Water-Cooled (c) (d) (e) 8 Ton Dual Circuit Voltage Compressor RLA 208/ ea ea. Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 3/ / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 28

29 Electrical Data - Water-Cooled (c) (d) (e) 10 Ton Dual Circuit Voltage Compressor RLA 208/ ea ea. Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1-1/ / Heat Heat / Reheat Reheat / / Heat Heat / Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 29

30 Electrical Data - Evaporator Section (c) (d) (e) 2 Ton Single Circuit Voltage 208/ / Evaporator Motor Electric Heat (a) (b) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / Heat / Heat / Reheat / Reheat / / Heat / Heat / Reheat / Reheat / / Heat / Heat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations/applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 30

31 Electrical Data - Evaporator Section (c) (d) (e) 3 Ton Single Circuit Voltage 208/ / Evaporator Motor Electric Heat (a) (b) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 31

32 Electrical Data - Evaporator Section (c) (d) (e) 4 Ton Single Circuit Voltage 208/ / Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations/applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 32

33 Electrical Data - Evaporator Section (c) (d) (e) 5 Ton Single Circuit Voltage 208/ / Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat / / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat / / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 33

34 Electrical Data - Evaporator Section (c) (d) (e) 6 Ton Dual Circuit Voltage 208/ Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1/ / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat / / Heat / Heat Heat Heat / Reheat / Reheat Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 34

35 Electrical Data - Evaporator Section (c) (d) (e) 8 Ton Dual Circuit Voltage 208/ Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 3/ / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat / / / Heat / Heat / Heat / Heat / Reheat / Reheat / Reheat / Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 35

36 Electrical Data - Evaporator Section (c) (d) (e) 10 Ton Dual Circuit Voltage 208/ Evaporator Motor Electric Heat (a) (b) (f) Humidifier Unit HP FLA KW Amps Used As Amps MCA MOP 1-1/ / Heat Heat / Heat Heat / Reheat Reheat / Reheat Reheat / / Heat Heat / Heat Heat / Reheat Reheat / Reheat Reheat (a) Electric heaters nominally rated and listed at 220 or 460 volts. (b) Electric heaters listed being used for heat or reheat as indicated. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. (f) Under some situations / applications it may be required to provide dual point power to units with electric heat. This is beyond the Engineering Guide capability. Use UCA Select to get a determination or contact a local rep or the factory for a determination. Subject to change without notice. 36

37 Electrical Data - Air-Cooled Condensing Section (a) (b) (c) Voltage Compressor RLA Condenser Motor Unit HP FLA MCA MOP 208/ / / / / / / / / / / / / / / / / / / / / / / / / / Ton Single Circuit 3 Ton Single Circuit 4 Ton Single Circuit 5 Ton Single Circuit (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. (c) All unit electrical capabilities not shown. Contact factory for specific unit combinations. Subject to change without notice. 37

38 Electrical Data - Air-Cooled Condensing Section (a) (b) (c) Voltage Compressor RLA Condenser Motor Unit HP FLA MCA MOP 208/ ea. 1-1/ ea. 1-1/ / ea ea Ton Dual Circuit 6 Ton Dual Circuit 10 Ton Dual Circuit 208/ ea ea. (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. (c) All unit electrical capabilities not shown. Contact factory for specific unit combinations. 1-1/ / Subject to change without notice. 38

39 Electrical Data - Air-Cooled Condenser (a) (b) (c) 2 Ton Single Circuit 3 Ton Single Circuit 4 Ton Single Circuit 5 Ton Single Circuit 6 Ton Dual Circuit 8 Ton Dual Circuit 10 Ton Dual Circuit Voltage Condenser Motor Unit HP FLA MCA MOP 208/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. (c) All unit electrical capabilities not shown. Contact factory for specific unit combinations. Subject to change without notice. 39

40 Electrical Data - Water-Cooled Condensing Section (a) (b) (c) 2 Ton Single Circuit 3 Ton Single Circuit 4 Ton Single Circuit 5 Ton Single Circuit 6 Ton Dual Circuit 8 Ton Dual Circuit 10 Ton Dual Circuit Voltage Compressor Unit RLA MCA MOP 208/ / / / / / / / / ea ea / ea ea / ea ea (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. (c) All unit electrical capabilities not shown. Contact factory for specific unit combinations. Subject to change without notice. 40

41 Water-Cooled Piping Arrangements 2-Way Single Circuit 2-Way Single Circuit with Bypass 2-Way Valve 2-Way Valve Water In Water In N.O. Solenoid Valve Water Out Water Out Condensing Coil Condensing Coil 3-Way Single Circuit 3-Way Valve 2-Way Dual Circuit with Water Side Economizer Water In Water Side Economizer Condensing Coil Water Out Evaporator Section Condensing Section 2-Way Valve Water In 3-Way Valve Water Out Condensing Coil 2-Way Single Circuit with Bypass and Water Side Economizer 3-Way Single Circuit with Water Side Economizer Water Side Economizer Water Side Economizer Evaporator Section Evaporator Section Condensing Section 2-Way Valve Water In 3-Way Valve Condensing Section 3-Way Valve Water In 3-Way Valve Condensing Coil N.O. Solenoid Valve Water Out Condensing Coil Water Out Subject to change without notice. 41

42 Water-Cooled Piping Arrangements 2-Way Dual Circuit 2-Way Valve Condensing Coil 2-Way Valve Water In Water Out 2-Way Dual Circuit with Bypass 2-Way Valve Water In N.O. Solenoid Valve Water Out Condensing Coil 2-Way Valve Condensing Coil Condensing Coil 3-Way Dual Circuit 3-Way Valve Water In Condensing Coil Water Out 2-Way Valve Condensing Coil 2-Way Dual Circuit with Bypass and Water Side Economizer 3-Way Dual Circuit with Water Side Economizer Water Side Economizer Water Side Economizer Evaporator Section Evaporator Section Condensing Section 2-Way Valve Water In 3-Way Valve Condensing Section 3-Way Valve Water In 3-Way Valve N.O. Solenoid Valve Water Out Water Out Condensing Coil Condensing Coil 2-Way Valve 2-Way Valve Condensing Coil Condensing Coil Subject to change without notice. 42

43 Water-Cooled Piping Arrangements 2-Way Dual Circuit with Water Side Economizer Water Side Economizer Evaporator Section Condensing Section 2-Way Valve Water In 3-Way Valve Condensing Coil Water Out 2-Way Valve Condensing Coil Subject to change without notice. 43

44 Basic Model Configurations Illustrated below are possible cabinet configurations. Not all combinations are shown. If a configuration is required that is not shown, please contact the factory to confirm if it is possible. Condensing Section Control Boxes Condensing Section Control Boxes Evaporator Section Filter Box Filter Box Condensing Section - Back Inlet & Outlet Evaporator Section - Front Return & Supply Condensing Section - Back Inlet & Outlet Evaporator Section - Side Return / Front Supply Top Discharge Condensing Section Evaporator Section Control Boxes Condensing Section Evaporator Section Control Boxes Filter Box Top Supply Filter Box Condensing Section - Back Inlet & Outlet Evaporator Section - Front Return / Top Supply Condensing Section - Back Inlet / Top Discharge Evaporator Section - Front Return & Supply Condensing Section Evaporator Section Control Boxes Condensing Section - Side Inlet & Back Outlet Evaporator Section - Front Return & Supply Plan Views, Not To Scale Filter Box Due to product flexibility some options and configurations may not be shown. Contact factory for specials. Subject to change without notice. 44

45 Basic Model Configurations Illustrated below are possible cabinet configurations. Not all combinations are shown. If a configuration is required that is not shown, please contact the factory to confirm if it is possible. Evaporator Section Control Box Condensing Section Control Box Filter Box Evaporator Section - Front Return & Rear Supply Condensing Section - Back Inlet & Rear Discharge Filter Box Evaporator Section Control Box Condensing Section Control Box Evaporator Section - Side Return & Front Supply Condensing Section - Side Inlet & Rear Discharge Top Discharge Evaporator Section Control Box Condensing Section Control Box Filter Box Evaporator Section - Front Return & Top Supply Condensing Section - Back Inlet / Top Discharge Plan Views, Not To Scale Due to product flexibility some options and configurations may not be shown. Contact factory for specials. Subject to change without notice. 45

46 Basic Unit Dimensions 56 B A B A B A B A CONDENSING SECTION EVAPORATOR SECTION TON SINGLE CIRCUIT TON SINGLE CIRCUIT TON DUAL CIRCUIT 10 TON DUAL CIRCUIT 32 Air-Cooled Water-Cooled A B / / For specific unit dimensions, please visit our website at or click here if you are viewing this document electronically. Subject to change without notice. 46

47 Service Clearance - Plan View 36" 36" Voltage 208 / Variation 187 / / 504 Cooling (Air Entering Evaporator) DB (min./max.) 65 / 110 WB (min./max) 57 / 72 Note: (a) Not all combinations may be valid (b) Dependent upon specific application, some additional refrigerant circuit considerations may be required. GPM / Ton (min./max.) 2.5 / 3.5 Water-Cooled Leaving Water Temp (min./max) 60 / 115 Note: (a) Not all combinations may be valid (b) Dependent upon specific application, some additional refrigerant circuit considerations may be required. Condensate Drain Pipes: Water Regulating Valves (a) Unit Sizing Miscellaneous Technical Data 3/4 IPS Circuits (Qty) Size 2 Single (1) 1/2" 3 Single (1) 3/4" 4 Single (1) 3/4" 5 Single (1) 1" 6 Dual (2) 3/4" Condensate Pump: (a) Shipped loose. (b) Externally mounted on left side of cabinet. Evaporator Blower VFD: (a) Must include Hot Gas Bypass or Freezestat on each circuit. (b) Pressure Transducer shipped loose for duct mounting. (c) Field installed and programmed. Motors: (a) 2 and 3 HP motors not available in Premium Efficiency in single phase. Electric Heaters: Finned Tubular type with individual contactor and circuit breaker for each stage. When the heater amps exceed 48 for a bank of heaters, SCR (Vernier control) is required. 8 Dual (2) 3/4" Electric heaters only available for use in return air stream. 300 FPM minimum face velocity. 10 Dual (2) 1" Hot Gas Bypass: Note: (a) Modulating Hot Gas Bypass can only be used on the lead circuit. Can put (a) Use when entering water temperature standard hot gas bypass on 2nd stage. will be < 65 F. (b) Must use Marvel Microprocessor or Johnson Control with Modulating HGB. Hot Gas Reheat: (a) Not available for split systems. Subject to change without notice. 47

48 Options SCR - Vernier control on first bank of electric heat. Requires a Marvel microprocessor or Johnson Controller for signal. Unit Interconnect Kits (Shipped Loose) - Used when system will be split in application. Condensate Pump (Shipped Loose) - Requires separate 115 volt power supply. Pump provided with power cord with 3-prong plug. Refrigerant Component Guidelines (a) (b) (c) (d) Equivalent Feet Oil Separator Accumulator Quench Valve Discharge Line > 100 X External Hot Gas Bypass Line > 50 X Liquid Line Net Down and > 50 Suction Line > 100 X X X Suction Line in > 100 F Ambient and > 50 X X Suction Line Down and > 50 X Note: (a) It is the customer s responsibility to verify refrigerant concentration limit compliance with the latest edition of ANSI / ASHRAE Std. 15. (b) Guidelines for cooling only applications. Contact factory for heat pump systems. (c) External Hot Gas Bypass Line Sizing - use half of the nominal compressor tonnage as a discharge line. (d) All field piping is to follow current industry accepted practices. Microprocessors Marvel Mini Basic Microprocessor Wall Display (shipped loose), Main Control Board, Real Time Clock Board, Air Proving Switch, Compressor High / Low Refrigerant Pressure Safeties and 100 of Cable Marvel Plus Full Featured Microprocessor Wall Display (shipped loose), Main Control Board, Real Time Clock Board, Air Proving Switch, Dirty Filter Switch, Drain Pan Overflow Switch, Compressor High / Low Refrigerant Pressure Safeties and 100 of Cable (Must use UCA provided cable, longer lengths available) Sensors Wall or Duct Mounted Temperature Wall or Duct Mounted Humidity Wall or Duct Mounted Temperature / Humidity BMS Serial Communication Board - BACnet (MS/TP or Ethernet), ModBus, LonWorks Duct Mounted Pressure Transformer (If VAV Application is Specified) Not Available with Marvel Mini. Subject to change without notice. 48

49 BASIC MODEL DESIGNATION EXAMPLE: C G AS 5 H 6 A X C, CW, H, HW, CCW, E, B or BC C Air-Cooled Air Conditioner CW Water-Cooled Air Conditioner H Air-Cooled Heat Pump HW Water-Cooled Heat Pump CCW Chilled Water Unit E Evaporator Section only of the unit (can be a prefix for some of the above) B Condensing Section only of the unit BC Condenser Section only of the unit 2. 2, 3, 4, 5, 6, 8, 10 Nominal Cooling Capacity in 3. G Common to all 4. 1, 3, 4 or 5 Indicates Voltage V, 1 PH (277 Volt Handled by Optional Buck-Boost Transformer) V, 3 PH 4 460V, 3 PH 5 575V, 3 PH 5. AS, A Quantity of Refrigerant Circuits AS Indicates 1 Circuit A Indicates 2 Circuit 6. H Unit Series 7. A Refrigerant Type A R-410A 8. 05, 10, 15, 20, 25 Indicates kw Rating for Heaters 9. V Indicates Vertical Stacking Unit 10. X Special Configuration Not all combinations of Basic Model Designations are valid. Check with the factory for correct model identification. Subject to change without notice. 49

50 NOTES: Subject to change without notice. 50

51 NOTES: Subject to change without notice. 51

52 Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 VariCool VAV, 9-70 VariCool EZ-Fit VAV, Alpha Aire CFM Portable Cooling and Heating Units 3-30 Horizontal 2-10 C-Series Horizontal 1-15 Special Configuration Engineered to Order OmegaAir Horizontal and Vertical 100% Outside Air CFM Authorized Distributor: LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA Phone: Fax: uca@unitedcoolair.com web: Copyright by United CoolAir Corporation All rights reserved. Manufacturer reserves the right to make changes without notice.

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

CoolSpot Engineering Guide

CoolSpot Engineering Guide Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product

More information

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons 491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h HORIZONTAL SERIES MiniPac HU024, HU036, HU048, HU060 DualPac HU072, HU096 MaxPac HU120, HU144, HU180 Horizontal packaged selfcontained, air cooled

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified Shelf Units 2, 3, and 4 ton R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing

More information

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) with refrigerant Product Description Performance and Electrical Data Dimensional Data Guide

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most

More information

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE SUBMITTAL DATA SHEET SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF:

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE 90.1 certification

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018 Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW INSTALLATION INSTRUCTIONS RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW 92-106595-01-00 TABLE OF CONTENTS Introduction.......................................

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

Split System Heat Pumps

Split System Heat Pumps Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

Service Step by Step Trouble-Shooting Check-List

Service Step by Step Trouble-Shooting Check-List WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms SKY-COM HI-CAP SERIES Precise Environmental Control SKY-COM 15 & 20 TON Series Suited for Telecommunications, Laboratories and Computer Rooms GENERAL MECHANICAL SPECIFICATIONS AIRFLOW CONFIGURATION Units

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in

More information

Unit Features & Benefits RQPM/RQRM Series

Unit Features & Benefits RQPM/RQRM Series 2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL MODEL DESCRIPTION Table of Contents The LAYTON Advantage... Total Protection----------------------------------------------------------

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton EP Water Source Heat Pump ½ to 6 Ton Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION INDEX Introduction....................................... 3 Checking Product Received.......................... 3 Standard Unit Features.............................. 3 Unit Dimensions...................................

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically

More information

Roof Top Packaged Unit (RTU-1) Specification

Roof Top Packaged Unit (RTU-1) Specification Roof Top Packaged Unit (RTU-1) Specification Item Tag(s) Qty Description Model Number A2 10 Ton 1 10 Ton R410A PKGD Unitary Gas/Electric TRANE: YHC120F3RLA--07C1 Product Data - 10 Ton R410A PKGD Unitary

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in the late

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual Liebert Mini-Mate2 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz Technical Data Manual Technical Support Site If you encounter any installation or operational issues with

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-532 Featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant RHGM- 090 & 120 SERIES NOMINAL SIZES 7.5 & 10, TONS [26 & 35 kw] TABLE OF CONTENTS Unit Features...3

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22) Engineering Manual R407c & R410a SC SpotCool 2 x 4 Packaged & Split Ceiling Mounted A/C s (DX & CW Systems) Features & Benefits 1 to 3 Ton Capacities Comfort Applications - General Office Spaces - Conference

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-529 REV. 6 Supersedes Form No. H11-529 Rev. 5 Featuring Industry Standard R-410A Refrigerant RHGL- 090, 120, 180 & 240 SERIES NOMINAL SIZES 7.5, 10, & 20 TONS [26, 35,

More information