1 QuadraTouch Pro Software Update Change Log Official Release vs. Beta Release (How to tell): Tools -> System Tools -> System Information and look for Official Release or Beta Release in the bottom right hand corner Known Issues: No Currently Known Issues V1.21: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers) NOTE: Required for all New Touchpanels (Rolling change 2018) New Touch Panel Back (BL2) Old Touch Panel Back Adjusted Several Functions to ensure proper operation on the BL2 Touchpanel Corrected Issue with Incoming Moisture Calibration (2 of 2) In Manual Operation you can now set the metering rolls anywhere between 0 and 100% regardless of Max/Min Limits. (Cross-Flow/Mix-Flow) Corrected Issue with Static Air Pressure Switch for Fan 1 not logging right for History Log. (Cross- Flow/Mix-Flow) Corrected Issue with User Unload Delay Timer always tripping at 2 minutes regardless of setting. (Cross- Flow/Mix-Flow) Made adjustment to Moisture Loop Calculations making it quicker to respond when near a roll limit. Enabled Multilingual Support for BL2 Touchpanels. Strings updated to Version 1.06 NOTE: A few dryers were shipped from the plant with the Beta Version 1.21 Release, they have strings version No Major Difference other than Multilingual Support is disabled. V1.20: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers) NOTE: NO LONGER REQUIRED to leave the TouchPanel on for 65 minutes after doing an update. Corrected issue with Static Sampling Replaced a file that was falsely flagging on some antivirus programs. Corrected issue with Incoming Moisture Sensor Calibration/Readout. (1 of 2) Updated History Log to include all alerts even when multiple faults are present. Added button to allow you to search for all times an alert has been logged.

2 Fixed issues with Faults on Tower Dryers based on Tower Dryer Model Choice. Fixed issue with Stabilization Time Calculation on Plenum 2 for Crossflow Dryers. Updated Strings File to 1.03 Added Calibration Offsets to the Data Log V1.19: (Required for All Dryers V1.15 to V1.18) Corrected issues with New Moisture Formulas/Calibration including Celsius Conversions Fixed Static Sampling on Portables not displaying when to sample. Repaired issue with 1 Fan Tower Fan Shutdown Delay Added Reduced Torque Starting Support for Towers V1.18: (Required for 1 Fan Tower Dryers V1.15 to V1.17) Corrected Tower Dryer PLC Issue where Single Fan Towers won t power main gas valve. (V1.15 V1.17) Lowered Discharge Moisture Setpoint minimum limit to 8% in order to allow for Canola. Added check for Stuck Screen on User Reset V1.17: Corrected PLC Bus Diagnostic not showing proper PLC Bus Structure (Cosmetic Only) Corrected issue with Network Repair Utility not properly naming the adapters. (Cosmetic Only) Corrected Analog Sensor not found Border. (Cosmetic Only) V1.16: Corrected PLC Software Compiling Issue only 1 Fan would start (V1.15) V1.15: NOTE: After updating to a Version greater than V1.15 you need to leave the Touch Panel on for at least 65 minutes. This will allow the database to fully rebuild. If you do not, it will do a Set Defaults procedure every time you power up the Touch Panel until it has had at least 65 minutes to run. Other than you having to change the settings to desired settings and recalibrate, it will not prevent you from running the dryer. Load Delay has been changed to delay the starting of the load auger and load auxiliaries, instead of just the load auxiliaries. It will now be the time delay between when the dryer calls for grain (paddle switches down) and when the load system starts. Strange I/O combination time for #94 has been extended to accommodate conveyor unload systems. Discharge Calibration procedure has been modified for portable dryers with static samplers. Fixed Bushel Counter in Automatic.

3 Discharge Minute Average/Sample Average has been added to portable dryers when static sampling is enabled. Also added to Remote App Display. Static Sampler error will not come up when static sampler not enabled. Added option to manually run setupnp script in Network Configuration. Change Meter Roll speed in remote access app added under grain details tab. Device ID generator modified for exceptions if your system is only generating a 7-character Device ID. Added OPC Server Maintenance feature in Maintenance Tools. (Auto Heal OPC server and install correct settings) Changed Communication Error flashing in header will direct you to communication error page (.pdf troubleshooting access) Added Kill Top Most feature to maintenance tools page. Will stop the TopMost app for 10 minutes to give better focus/control of applications running in the background. Added button in Maintenance Tools to reload the main script in the event of script error. Discharge Control Method fixed in continuous flow. Added Public IP popup Added script that automatically checks networking adapters for correct configuration during loading sequence. Added Network Diagnostic tool to help in remote access situations. Fixed Out of Wet Grain Timer for Grain Transfer and Added Separate Fill Timer for Grain Transfer Fixed Initial Fill Timer Fault Fixed Strange I/0 for Multi Fan Dryers Added Disable Moisture Sensor Analog Sensor Not Found Warning. Resets Automatically each time dryer is reset. Fixed/Updated Graphs to Improve Performance Added Network Repair Utility to diagnose and repair most common problems for Communication Error. Major changes to system to improve responsiveness. Added Grain Type Selection for: Corn, Soybeans, Canola, Hard Red Winter Wheat and updated the moisture calculation formulas for improved drying accuracy. Metering Roll Fault is now enabled on Mix Flow/Static Sampler Dryers. Combined Tower and Tower 10k PLC Programs. When updating PLC it no longer asks if it is a 10k Dryer. Updated Several PDF Files and added Portables Ladder Diagram Drawings.

4 V1.14: Pin Assignment change for 1 Fan Dryers with Incoming moisture Sensor (additional green card) Signal D5 Changes from 1.1 to 2.1. Adjust Roll Speed limits from continuous flow page fixed Adjust roll speed limits in manual control changes current manual roll speed if outside limits New popup keypad added for numerical values Tower Discharge Method Pop-up Added Confirmation screen added for switching into manual control from automatic Bushel Counter Ratio was not retained during shutdown fixed. Desktop Application for remote viewing added to project directory (requires Java). Remote Access Subscription Keys activated for smart phone and pc remote access. Ask your Sukup dealer for a remote access key (requires dealer activation). No restart required during software update. Software simply reloads itself Tower Dryers: Fan Shutdown Delay timer now always shuts off heater system during fan shutdown delay. Auto Update Feature. If the QuadraTouch Pro system is connected to the internet, it will periodically check for software upgrades, and download new versions automatically when available. Added Public IP display to Auto Update Page Added Discharge Moisture Alarm in Tools Menu. (Optional Fault Shutdown) Added Static Sampling to Portable Dryers. Configure in System Tools. (Optional Fault Shutdown) Added Networking Configuration Page to Maintenance tools. User adjustable Grain Transfer Out of Wet Grain Timeout added Added Recent Data Log to Graphs page. Graphs Containing the Actual Input Moisture have been switched from real-time to 1-min avg values. User Fault Text is now user selectable/editable in System Tools Menu. Pop-up reminder added to clean dryer and check sensors. Analog Signal Problem Reminder added to the header. Also prevents accessing automatic from manual mode. Screen will pop up only once. It will then stay Red in the header until the problem is fixed. Touch the Analog Sensor Missing message to pull up the Analog Sensor Missing screen.

5 Lock-Out Screen Added to System Tools Menu. QuadraTouch Pro is now configured for plug and play remote access. A Text Messaging notification Feature is also available for those who purchase remote access subscription keys. Purchase your remote access key through your Sukup Dealer. Mix Flow Dryer support added. Static Sampling for Portable Dryers added. Video Troubleshooting and support for Tower Dryers added. Updated.pdf content V1.13: Added EMOV position graphs Added Column Temp Graphs Tower Diagnostic page: #35 Customer Unload Interlock indication fixed Added Load Delay Visual timer to Tower Dryer Running Screen. Added Tower Static Sampling Error Pop-up Screen. Changed Default Value for Moisture Gain to 60. Changed Default Flame Timer for Towers to 300 sec. Pressure Transducer Values fixed for Auxiliary Device. Autobatch Time/Temp discharge fixed. Warm Up option added to Restart with Stabilization mode Provided Pop-up window for discharge method selection in continuous flow operation Program Updates after V1.13 will automatically reboot the PLC and HMI after program download. Added Manual scripted file transfer in APPS directory (for manual software transfer, refer to web instructions). Fixed Tower Fan Start Delay Timer 4 Fixed Tower Load Interlock #34. Also displays pop up when applicable. Grain Transfer added apply speed change button Added Fan/Model selection to system information page Added Update Instructions to QuadraTouch Update page Added Restart OPC server to Maintenance Page.

6 Strange I/O Combination shows trigger condition (why it had a strange I/O combo) and if the condition is still present. Changed Communications Timeout to 30 seconds from 20 seconds. Simplified input moisture calibration (if applicable). V1.12: Only necessary for Tower Dryers, no modifications made for 1-6 fan dryers Tower Modifications Calibration procedures for discharge and incoming moisture changed for static sampling. User auxiliary load and unload timers fixed Tower Diagnostics added / refined MST actuator and prox switch lights fixed. Added Maintenance tools button to communication error page Added 1 minute discharge average to running screen. Added Control Sample Average to running screen. This is the value used for MST control. Added.pdf for LME69 and SQM 50 Actuator V1.11: Improved program performance Remote client app support -Requires onsite internet access, free app download, and purchased license key T7101 Added Prox Switch Override button to admin tools page Complete wiring diagrams can be accessed on fault monitoring page Plenum > 275 degrees fault has been added to individual plenum fault menus Tower air switch strange I/O combo extended to 5 minutes Changed EMOV low fire position values for Tower Dryers Added 15 sec EMOV delay Added Column Temp Override Pins #246 and #243 were programmed backwards. No wiring changes are necessary Added.PDF content for Tower Dryers Added end of season maintenance notes for Tower Dryers Expanded Plenum Temperature Range for Tower Dryers Input MST control Enable / Disable button added to the Admin Tools page

7 Tower Diagnostics Page Link fixed

QuadraTouch Pro Software Manual Dryer Control System

QuadraTouch Pro Software Manual Dryer Control System QuadraTouch Pro Software Manual Dryer Control System Software is constantly changing. Make sure you are up to date with Sukup s newest software. New software and manuals are available for download at:

More information

Mixed Flow GRAIN DRYER PATENT PENDING

Mixed Flow GRAIN DRYER PATENT PENDING Mixed Flow GRAIN DRYER Low Maintenance Cleaning Energy Efficient Vacuum Cooling Simple Single-Conveyor Unloading QuadraTouch Pro Control System VACUUM-COOLING SUKUP EXCLUSIVE Sukup Manufacturing is the

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Dryer Master DM510 Commissioning Guide

Dryer Master DM510 Commissioning Guide COMMISSIONING GUIDE Dryer Master DM510 Dryer Moisture Systems Inc. 640 Superior Drive Waterloo, Ontario Phone 519.725.4700 Fax 519.885.4300 USA & Canada Toll Free 1-888-318-0009 E-mail: info@dryermaster.com

More information

WHEN TROUBLESHOOTING, PERFORM THE STEPS IN ORDER.

WHEN TROUBLESHOOTING, PERFORM THE STEPS IN ORDER. WHEN, PERFORM THE STEPS IN ORDER. BURNER WON T LIGHT Control System 1. Is the main interlock in auto? The burner will not light if the dryer is in manual mode b. No: Switch the main interlock to auto 2.

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide with Hirsch Velocity INT-HIRSCH-B-Rev1 2012 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted

More information

1 and 2 Fan Vision Series Portable Dryers

1 and 2 Fan Vision Series Portable Dryers 1 and 2 Fan Vision Series Portable Dryers Operator s Manual PNEG-1456 Date: 09-29-09 PNEG-1456 2 PNEG-1456 1 and 2 Fan Vision Series Portable Dryers Table of Contents Contents Chapter 1 Safety... 5 Safety

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide for Paxton Net2 Access Control Systems 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with

More information

Vision for Portable Dryers

Vision for Portable Dryers Vision for Portable Dryers Operation Manual PNEG-1739 Date: 06-21-10 PNEG-1739 2 PNEG-1739 Vision for Portable Dryers Table of Contents Contents Chapter 1 Safety...5 Safety Guidelines... 5 Dryer Operation...

More information

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller ProMtrac_Browser_Manual.docx (5/23/13) rev1: pn. 7501088 Please completely read through these operating instructions first! Do

More information

Smart thermostat with Humidification/De-humidification control

Smart thermostat with Humidification/De-humidification control x Smart thermostat with Humidification/De-humidification control Enter/Confirm Scroll Right = Increase Left = Decrease Back/Cancel TABLE OF CONTENTS Everyday Use 1. Adjusting Temperature...3 2. Adjusting

More information

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...

More information

Tri-Stack Smart System

Tri-Stack Smart System Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Dryer Master Inc. Dryer Master AM 3. Product Manual

Dryer Master Inc. Dryer Master AM 3. Product Manual Dryer Master Inc. Dryer Master AM 3 Revision 1.0 July, 2008 Revision 1.2 February, 2009 Revision 1.3 March, 2009 Revision 1.4 September, 2013 Prepared by: Dryer Master Inc. Dryer Master Inc 2008, 2009,

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Monitor Alarms and Events

Monitor Alarms and Events What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Which Events Are Supported?, page 5 Set Alarm and Event Management Preferences, page 5 Interpret Event and Alarm

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center 5 System Integration Guide Avigilon Control Center 5 System Integration Guide with Lenel Facility Commander Wnx INT-FCWNX-A-Rev1 2010 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license

More information

Integration Guide AXIS Camera Station and AXIS A8004-VE

Integration Guide AXIS Camera Station and AXIS A8004-VE HOW TO Integration Guide AXIS Camera Station and AXIS A8004-VE Created: May 11, 2015 Last updated: May 11, 2015 1 Please note that AXIS does not take any responsibility for how this configuration may affect

More information

2 & 3 Module DriTek Plus Dryers

2 & 3 Module DriTek Plus Dryers OPERATOR S MANUAL 2 & 3 Module DriTek Plus Dryers Division of ffi Corporation 1004 E. Illinois St. Assumption, IL 62510 PNEG-1540 Date: 09-15-2006 PNEG-1540 CONTENTS INTRODUCTION...4 OPERATING PRECAUTIONS...4

More information

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel Manual# 1100334 User s Manual 200 Series DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel Rev. March 2012 User's Manual for the Marine Pro 200 Series ~~~ DCU 210 Diesel Engine Control Unit DCU

More information

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3 Manual# 1100268 User s Manual DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3 Table of Content GENERAL INFORMATION... 3 ABOUT THIS MANUAL... 3 400 SERIES OVERVIEW... 3 Available Modules...

More information

Liebert icom. Intelligent Communication and Monitoring. Installer/User Guide

Liebert icom. Intelligent Communication and Monitoring. Installer/User Guide Liebert icom Intelligent Communication and Monitoring Installer/User Guide Technical Support Site If you encounter any installation or operational issues with your product, check the pertinent section

More information

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel

More information

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output Model LFS108B Copyright 2018 - LLC. All rights reserved. Table of Contents Quick Start... 3 1- Introduction... 4 2-

More information

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9 Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,

More information

D3D Wi-Fi GSM Smart Alarm System -User Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM

More information

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel DS9400 Series EN Release Notes for Firmware V2.07 Fire Alarm Control Panel DS9400 Series Release Notes for Firmware V2.07 Trademarks Trademarks Gentex is a trademark of Gentex Corporation, Fire Protection

More information

Tower Dryers U Bu/Hr. QuadraTouch Controls Industrial Grade Components

Tower Dryers U Bu/Hr. QuadraTouch Controls Industrial Grade Components Tower Dryers U41 1000-7000 Bu/Hr. QuadraTouch Controls Industrial Grade Components ADVANTAGES 1 ROTARY SENSORS for choke fill or demand fill are standard. STAINLESS STEEL outer screens, nuts, and bolts

More information

Managing Network Alarms and Events

Managing Network Alarms and Events 9 CHAPTER Prime Performance Manager allows you to view alarms and events that occur in your network. The following topics provide information about displaying network alarms and events: Displaying Active

More information

Dryer Moisture Systems Inc. Dryer Master GM 2. Product Manual. Revision 1.0 January, 2007 Revision 1.01 March, Prepared by:

Dryer Moisture Systems Inc. Dryer Master GM 2. Product Manual. Revision 1.0 January, 2007 Revision 1.01 March, Prepared by: Dryer Moisture Systems Inc. Dryer Master GM 2 Revision 1. January, 27 Revision 1.1 March, 27 Prepared by: Dryer Moisture Systems Inc. Dryer Moisture Systems Inc. Page: 2 Table of Contents 1 INTRODUCTION...

More information

Installation, Configuration and User Manual

Installation, Configuration and User Manual Model 8826 System Controller Model 8826 System Controller Installation, Configuration and User Manual READ AND SAVE THESE INSTRUCTIONS WELCOME Thank you for choosing the Aprilaire HVAC Automation System.

More information

[ [ ADMIN PANEL USER GUIDE

[ [ ADMIN PANEL USER GUIDE [ [ ADMIN PANEL USER GUIDE ADMIN PANEL USER GUIDE 2 Contents Logging In & Systems Overview 3 System Details 5 Analytics 6 View Alarms 8 Manage Alarms 9 Create Alarms 10 Device Reporting Alarm 11 Monthly

More information

Table of Contents. i-vu CCN Standard 4.2

Table of Contents. i-vu CCN Standard 4.2 i-vu CCN Standard 4.2 Owner's Guide CARRIER CORPORATION 2009 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-381-01 7/13/2009 Table of Contents Accessing your

More information

DEFA HOME. User Manual Base Unit PRO

DEFA HOME. User Manual Base Unit PRO DEFA HOME User Manual Base Unit PRO Table of Contents Overview 5 Logging into the app 9 Home 10 Calendar 13 Adding an event 14 Editing an event 15 Zones 16 Switch mode 17 Thermostat mode 19 Regulator

More information

Yokogawa DX Ethernet Driver Help Kepware Technologies

Yokogawa DX Ethernet Driver Help Kepware Technologies Yokogawa DX Ethernet Driver Help 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 4 Overview 4 Device Setup 5 Communications Parameters 7 Optimizing Your Ethernet Communications 9 Data

More information

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Wilo CO-Helix Booster Systems. Product Presentation July, 2017 Wilo CO-Helix Booster Systems Product Presentation July, 2017 Pioneering for You Intelligent Pumps Save energy & optimize performance Technological innovation focus largest R&D development facility in

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Velocity INT-HIRSCH-A-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation of this

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL Operation Manual Celltrol II Bioreactor Control System Page 1 of 33 Table of Contents 1) Introduction... 3 1.1) Scope of Document... 3 1.2) Control System Overview... 3 1.3) Introduction to Celltrol II...

More information

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A i.c³ User Guide For Helmer i.series Ultra-Low Freezers 360175-A/A Document History Revision Date CO Supersession Revision Description A 18 APR 2014* 9275 n/a Initial release. * Date submitted or change

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual Ellis Dryer Control Configuration and Operation Manual Revised 1/19/2004 Table of Contents 1 Introduction... 7 1.1 Hardware Specifications... 7 1.2 Software Features... 7 1.3 Warranty... 8 1.3.1 Terms...

More information

Lighting Xpert Insight User Manual

Lighting Xpert Insight User Manual Lighting Xpert Insight User Manual Table of Contents 1 About This Document... 3 1.1 Key Terms... 3 1.2 Related Fifth Light Documentation... 3 2 Lighting Xpert Insight Overview... 4 2.1 Key Features...

More information

Security Escort Central Console Software SE2000 Series

Security Escort Central Console Software SE2000 Series Release Notes Security Escort Central Console Software SE2000 Series Table of Contents 1 Security Escort v2.18.1.0... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions...

More information

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N: User Manual Rotem One Touch Rotem One Touch Ag/MIS/UmGB-2603-06/18 Rev 1.0 P/N: 110741 Rotem One Touch User Manual Revision: N.1.0 of 02.2018 Product Software: 7.14 This manual for use and maintenance

More information

DryLINK TRAINING Phoenix DryMAX XL and DryLINK

DryLINK TRAINING Phoenix DryMAX XL and DryLINK DryLINK TRAINING Phoenix DryMAX XL and DryLINK FREE MOBILE APP 125 PPD XL LGR DEHUMIDIFIER WITH BLUETOOTH BE EVERYWHERE AT ONCE TABLE OF CONTENTS Introduction...3 Initial Setup Downloading the App...4

More information

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2017, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACC, AVIGILON CONTROL CENTER,

More information

LUFKIN WELL MANAGER MODBUS MAP

LUFKIN WELL MANAGER MODBUS MAP LUFKIN WELL MANAGER MODBUS MAP RPC APPLICATION DATE: VERSION: REVISION: FIRMWARE VERSION: 1/30/2012 6.16 6.16 Lufkin Automation Page 2 of 104 Revision History Revision Date 0.01 5/7/01 0.02 5/8/01 0.03

More information

F-Series Tower Drying

F-Series Tower Drying Tower Dryers F-Series Tower Drying F-Series Tower Drying We define grain drying. We define grain drying. FFI Features Gravity inlet does not require leveling auger, reducing the number of moving parts.

More information

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station. DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station. The following steps outline the correct sequence to

More information

Patriot Systems Limited

Patriot Systems Limited COPYRIGHT 1997 - The Patriot Systems Ltd. Patriot Alarm Monitoring Automation Package is licensed for use on one computer, by the original person, or company, or organization whose name is registered with

More information

ONYXWORKS AND FIRSTVISION. Version 4

ONYXWORKS AND FIRSTVISION. Version 4 ONYXWORKS AND FIRSTVISION Version 4 Version 4: Next Generation CONNECTED SOLUTIONS ONYXWorks FirstVision 2 ONYXWORKS Version 4 New to ONYXWorks v4.30 Look Ahead Test Monitoring Configuration Tool Display

More information

Wiser Air User Interface Guide. Thermostat

Wiser Air User Interface Guide. Thermostat Wiser Air User Interface Guide Thermostat 2 User Guide Wiser Air Scope This document outlines the user interface features of the Wiser Air smart thermostat. It is intended to support individual users and

More information

Daikin ENVi Thermostat installation overview

Daikin ENVi Thermostat installation overview Daikin ENVi Thermostat installation overview RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL Presenter s Name Presenter s Title Daikin ENVi system overview (web based thermostat) Slide 2 Daikin ENVi System Overview

More information

SIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide

SIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management

More information

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1 Avigilon Control Center 5 System Integration Guide with STENTOFON AlphaCom INT-STENTOFON-C-Rev1 2013 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

Operation Manual. Programmable Logic Controller

Operation Manual. Programmable Logic Controller Operation Manual Programmable Logic Controller Part No. 9983-0000-E01 / January 2018 OPERATION MANUAL TABLE OF CONTENTS CUSTOMER SERVICE 3 CONTACT INFORMATION 3 ORDER INFORMATION 3 INTRODUCTION 4 THE PROCESS

More information

Grain Dryers CROSS FLOW

Grain Dryers CROSS FLOW CROSS FLOW Grain Dryers QuadraTouch Pro TM Controls Accurate Moisture Sensing Exclusive Quad Metering Rolls Exclusive Grain Cross-Over TM System on Stacked Dryers Why A Sukup Grain Dryer? Sukup Manufacturing

More information

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera* Package Content 1 x Gateway 1 x Voice Siren 1 x IP Camera* Register the Gateway via PC Create a new account at www.elro-smartalarm.com 1. Click on Create a new account 1 x PIR Motion 1 x Magnetic 1 x Remote

More information

i-vu CCN 4.0 Owner s Guide

i-vu CCN 4.0 Owner s Guide i-vu CCN 4.0 Owner s Guide CARRIER CORPORAION 2007 A member of the United echnologies Corporation family. Stock symbol UX. 11-808-377-01 07/07 able of Contents ACCESSING YOUR SYSEM... 3 YOUR SYSEM DEAILS...

More information

Dryer Moisture Systems Inc. Dryer Master M 2. Product Manual

Dryer Moisture Systems Inc. Dryer Master M 2. Product Manual Dryer Moisture Systems Inc. Dryer Master M 2 Revision 1. January, 27 Revision 1.1 March, 27 Revision 1.2 June, 27 Revision 1.22 July, 27 Revision 1.22.1 January, 28 Revision 1.22.2 April, 28 Revision 1.23

More information

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2 Niagara4 Technical Certification Program Student Guide DAY 1 Welcome Course Introduction Platforms & Stations Niagara4 Fundamentals Simple Logic: Hot Water Pump Control (Thermostatic) Simple Logic: Hot

More information

SIMATIC IPC DiagBase SIMATIC. Industrial PC. Introduction. DIAG software components. Quick-Start Guide. Hardware and software requirements

SIMATIC IPC DiagBase SIMATIC. Industrial PC. Introduction. DIAG software components. Quick-Start Guide. Hardware and software requirements Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management

More information

Platinum Touch/Rotem One Touch

Platinum Touch/Rotem One Touch User Manual Platinum Touch / Rotem One Touch Platinum Touch/Rotem One Touch Climate Controllers Ag/MIS/UmGB-2583-05/18 Rev 1.0 P/N: 116556 Platinum Touch/Rotem One Touch User Manual Revision: N.1.0 of

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0 Avigilon System Integration Guide Avigilon Control Center with AMAG Symmetry Security Management System 7.0 2013-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, HDSM, HIGH

More information

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on. DRYER OPERATION - START-UP INITIAL SETUP PARAMETERS Turn the control power switch to on. When the Boot Screen appears touch the START DRYER button. The computer will run a quick check of the system network

More information

*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide

*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide Aurora Touch UPC Kit Instruction Guide For use in single compressor water-to-air equipment utilizing fi rmware UPCSWASTD01-01 Aurora Touch UPC Kit Instruction Guide *IG1583EW* IG1583EW 08/14 Aurora Touch

More information

Portable Dryer Touch Screen Controls

Portable Dryer Touch Screen Controls Portable Dryer Touch Screen Controls and Reference Manual PNEG 1509 PNEG 1509 Date: 1 23 08 Reference Table of Contents TABLE OF CONTENTS DRYER SAFETY & DRYER INFORMATION...4 SPECIAL SETUP SCREENS...5

More information

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on. DRYER OPERATION - START-UP INITIAL SETUP PARAMETERS Turn the control power switch to on. When the Boot Screen appears touch the START DRYER button. The computer will run a quick check of the system network

More information

3D_ISS. Integrated Software System. User Guide Manual

3D_ISS. Integrated Software System. User Guide Manual 3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development

More information

Using ANM Mobile CHAPTER

Using ANM Mobile CHAPTER CHAPTER 19 Date: 3/22/13 This chapter describes Cisco ANM Mobile, which allows you to access your ANM server or ANM Virtual Appliance and manage your devices using a mobile device such as an iphone or

More information

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat. Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat

More information

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide System Reset Trou ble Silence Ala rm Silence Manual Ala rm ENTER NO YES Letters Numb ers Keyword Radionics System Reset Trouble Silence Alarm Silence Manual Alarm ENTER NO YES Le ters Numbers Keyw ord

More information

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright CG500SKE SKYEYE GATEWAY USER MANUAL CG500SKE SkyEYE Gateway VERSION 1.2 26 OCTOBER 2014 Disclaimers and Copyright Nothing contained in this publication is to be construed as granting any right, by implication

More information

Dryer Master DM510 Users Guide

Dryer Master DM510 Users Guide Dryer Master DM510 Users Guide Dryer Moisture Systems Inc. 115 Ardelt Ave. Kitchener, Ontario Phone 519.725.4700 Fax 519.885.4300 USA & Canada Toll Free 1-888-318-0009 E-mail: info@dryermaster.com Reminder

More information

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3 Configuration Instruction Integration of IPS Video Analytics on Axis Cameras with a Milestone XProtect Video Management System Contents 1 Introduction... 1 2 Data transmission... 2 3 Compatibility... 3

More information

LineGuard 2300 Program User Manual (FloBoss 107)

LineGuard 2300 Program User Manual (FloBoss 107) Form A6251 Part Number D301346X012 November 2012 LineGuard 2300 Program User Manual (FloBoss 107) Remote Automation Solutions Revision Tracking Sheet November 2012 This manual may be revised periodically

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Oracle Communications Performance Intelligence Center

Oracle Communications Performance Intelligence Center Oracle Communications Performance Intelligence Center System Alarms Guide Release 10.2.1 E77506-01 June 2017 1 Oracle Communications Performance Intelligence Center System Alarms Guide, Release 10.2.1

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager Avigilon System Integration Guide for the Avigilon Control Center and Access Control Manager 2014-2016, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, AVIGILON CONTROL CENTER,

More information

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering and Connecting the GDS3710... 5 Power and Data PINs... 5 Alarm In and Alarm Out PINs... 6 DETECT AND

More information

Monitor Alarms and Events

Monitor Alarms and Events This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,

More information

WF/DV7500, 6500, Smart Home Integration

WF/DV7500, 6500, Smart Home Integration WF/DV7500, 6500, 6200 Smart Home Integration I N T R O D U C T I O N Push, open and insert Smart Home Adapter to activate Smart control/monitor I N T R O D U C T I O N Smart Home Adapter SPEC - 67mm *

More information

Skipper's Mate. Sensor Testing. Version December Table of Contents

Skipper's Mate. Sensor Testing. Version December Table of Contents Version 1.0.2 18 December 2017 Table of Contents 1. Introduction...1 2. Types of Sensor and Alarm...1 3. Where Can I See Graphs?...1 4. Where Do I Change Settings for Graphs & Alarms?...2 5. Turning OFF

More information

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors 1 Set Up After downloading the Weatherhub app, follow these steps: 1.1 Connect the Gateway Connect

More information

Operational Overview and Controls Guide

Operational Overview and Controls Guide DOCUMENT: ECSEQ2-2 EFFECTIVE: 02/26/10 SUPERSEDES: 02/14/07 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company The Monitoring System Rees Scientific An ISO 9001:2008 Company About Rees Scientific Rees Scientific specializes in protecting your valuable assets. Since 1982, Rees Scientific has been the industry standard

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

MultiSite Manager. Setup Guide

MultiSite Manager. Setup Guide MultiSite Manager Setup Guide Contents 1. Introduction... 2 How MultiSite Manager works... 2 How MultiSite Manager is implemented... 2 2. MultiSite Manager requirements... 3 Operating System requirements...

More information

7:00AM 1:00AM ET 7:00 AM 12:00AM ET

7:00AM 1:00AM ET 7:00 AM 12:00AM ET Agent Guide Homebase intouch Customer Service (877) NRT-HELP Help@HomebaseinTouch.com M-F: 7:00AM 1:00AM ET Weekends: 7:00 AM 12:00AM ET Version 1.1 October 2012 Contents What is Homebase intouch?... 4

More information

EXPORTING ALARM SETPOINTS IN SIEMENS PCS7

EXPORTING ALARM SETPOINTS IN SIEMENS PCS7 2017 Siemens Automation Summit EXPORTING ALARM SETPOINTS IN SIEMENS PCS7 Jared Romano, Pigler Automation usa.siemens.com/summit 2017 Automation Summit Title: EXPORTING ALARM INFORMATION FROM SIEMENS PCS7

More information

ATS2000/3000/4000/4500 Control Panel. Programming guide

ATS2000/3000/4000/4500 Control Panel. Programming guide ATS2000/3000/4000/4500 Control Panel Programming guide Version 2.01 (SR_F), June 2004 Aritech is a GE Interlogix brand. www.aritech.com Copyright (c) 2003 GE Interlogix B.V.. All rights reserved. GE Interlogix

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information