HUMIDIFICATION-DEHUMIDIFICATION SYSTEM IN A GREENHOUSE FOR SUSTAINABLE CROP PRODUCTION

Size: px
Start display at page:

Download "HUMIDIFICATION-DEHUMIDIFICATION SYSTEM IN A GREENHOUSE FOR SUSTAINABLE CROP PRODUCTION"

Transcription

1 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt 849 HUMIDIFICATION-DEHUMIDIFICATION SYSTEM IN A GREENHOUSE FOR SUSTAINABLE CROP PRODUCTION J.S. Perret 1 ; A.M. Al-Ismaili 1 ; S.S. Sablani 2 1 Department of Soils, Water and Agricultural Engineering, 2 Department of Food Science, College of Agricultural and Marine Sciences, Sultan Qaboos University, P.O. Box 34, Al-Khod 123, Sultanate of Oman; of corresponding author: perret@squ.edu.om ABSTRACT Prolonged aridity in the Sultanate of Oman has resulted in freshwater deficit in some parts of the country. In coastal areas, the aridity coupled with over-pumping of groundwater have often resulted in seawater intrusion. Looking for alternatives to provide freshwater for domestic, industrial and agricultural purposes is an ultimate goal for the government. The use of solar radiation in greenhouses to desalinate saline/brackish water was proposed as an alternative to provide freshwater for irrigation. This paper presents a study aimed at constructing and preliminary testing a humidification-dehumidification system in a Quonset greenhouse for producing freshwater. This greenhouse was modified to work with two humidifiers (i.e., evaporating pads), to increase water vapor inside the greenhouse as much as possible, and two dehumidifiers (i.e., condensers) to condense this water vapor. After evaporation, water leaving the humidifiers was cooler than the incoming water. This cooled water was pumped to the two dehumidifiers and acted as a coolant. Preliminary testing of the performance of the greenhouse showed an increase in the amount of water vapor after the second humidifier. The temperature of the dehumidifiers was always lower than the dew-point temperature of the air passing through them. This meant that there was a potential for condensation. Key Words: Solar Desalination, Greenhouse, Dehumidification, Humidification INTRODUCTION Arid regions rely entirely on irrigation for crop production and as a result, up to 95% of fresh water withdrawn is generally used by the agricultural sector (Al-Mumtaz [1]; Abdel-Rahman & Abdel-Magid [2]; Abdel-Rahman [3]; Al-Ajmi and Abdel Rahman [4]; Norman et al. [5]). Inevitably, such an intensive demand puts considerable pressure on renewable water resources which often leads to groundwater deficit and

2 850 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt depletion. The economical and social consequences are obvious in many coastal regions of arid countries such Oman where the overuse of groundwater has caused saline intrusion which has reduced the ability to grow crops and resulted in agricultural land being discarded. Long-term solution to this crisis lies in the 1) development and/or implementation of good agricultural/water management practices and water conservation techniques and 2) the augmentation of the fresh water resources through desalination, reuse of treated wastewater, artificial recharge of aquifers, fog collection, etc. (Goosen et al. [6]; [2]). The cost fuel powered desalination techniques (US$ /m 3 of fresh water depending upon the size of the plant and technique employed) is not feasible for arid land agriculture (Goosen et al. [7]). Arid countries may suffer from lack of fresh water but they generally may benefit from a great solar energy potential. This potential combined the development of saline water purification techniques may provide sustainable solution to supply dry regions with fresh water (Chaibi [8]). This study explores the potential of augmentation of the fresh water resource through solar desalination in a greenhouse structure. This concept called Seawater Greenhouse (Paton and Davis [9]), uses the solar desalination principle and works by saturating the air with moisture vaporizing from saline water inside a greenhouse and later dehumidifying, thus, causing freshwater condensation. Recently, Goosen et al. [7] stated that assistance is needed in the design and optimization of the humidification/dehumidification Seawater Greenhouse, in particular in the thermodynamic and economic simulation/ modeling, and construction of greenhouses using local materials. The implementation of the seawater greenhouse in Oman offers great potential, however, it requires, initially, the design and construction of a pilot greenhouse to better understand and optimize the processes of humidification and dehumidification. Humidification of air followed by dehumidification of water vapor to collect freshwater is not a new concept (Delyannis and Belessiotis [10]), but combining these processes in a greenhouse is new (Goosen et al. [7]). In 1992, Lights Work Limited at the UK designed a pilot solar humidification-dehumidification system in a greenhouse type structure for crop cultivation and seawater desalination (Paton and Davis [9]; Goosen et al. [7]; Sablani et al. [11]). This greenhouse was constructed on the Canary Island of Tenerife. Goosen et al. [7] reported that water production by this system was more than crop water requirement of the plant in the greenhouse. Water production is influenced strongly by the temperature of the condenser (Bailey and Raoueche [12]) that should be maintained at levels below the saturation temperature of the moist air in order to form condensation. This system is suitable for arid regions located on the coast (Bailey and Raoueche [12]; Sablani et al. [11]) or inland with shortage of freshwater but access to saline/brackish groundwater.

3 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt 851 MATERIALS AND METHODS This study was carried out in a Quonset greenhouse located at the Agricultural Experimental Station of Sultan Qaboos University, Oman (Figure 1). Originally, this greenhouse had a fan/pad evaporative system consisting of two exhaust fans and a wall of cellulose pads of 6 m wide x 1.5 m high. One pump was used to drive water from an underground sump tank to the top surface of the pads. Water flowed by gravity on the pads and was collected in a gutter located at the bottom of the pads and redirected to the sump tank. In order to introduce the concept of humidification/dehumidification in this greenhouse, several modifications were made. These modifications are briefly discussed below. Figure1. Modified quonset greenhouse at the agricultural experiment station 1. Design and Construction of a Movable Evaporative Cooling Frame Due to the expected increase in air temperature and air capacity as air moves towards the fans, a second wall of evaporative cooling pads was designed and constructed. The pads were mounted on a frame having the same dimensions as the first wall of evaporative cooling pads to maintain the airflow rate through the corrugated cellulose material. The frame was mounted on wheels to test various positions inside the greenhouse. The corrugated cellulose pads were 0.1m thickness with a surface area of 45 m 2 per square meter of pad. Figure 2 shows the movable frame supporting the cooling pads.

4 852 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt Figure 2. Moving frame mounted on wheels for the second wall of evaporative cooling pads 2. Design and Construction of the Condensers Frame As mentioned earlier, if moist air is cooled below its dew-point temperature, the water vapor in the air starts condensating (Fujii [13]; Sauer & Howell [14]; Moran & Shapiro [15]; Mangold et al. [16]; Huang, [17]). Two 0.9x0.9 m tube-and-fin cross-flow condensers were used (Figure 3) to investigate the possibility of reducing the temperature of the air below its dew-point. These condensers consisted of three rows of brass tubes connected by copper fins. They were mounted on a movable frame to allow different configurations in the greenhouse. Water flowing down the front pads was circulated in the condensers as a coolant since it has been cooled by evaporation. The condensers dimensions were based on availability from a local manufacturer. At this stage, the main purpose of this study was not to optimize the design and size of the condenser but rather to verify if the coolant temperature was below the dew-point of the air entering it and hence validate whether condensation could occur. Figure 3. Schematics of the cross flow condenser

5 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt Water Circulation System A 3.8 m 3 reservoir was placed outside the greenhouse and oriented south to maximize solar energy input and hence, increase water temperature inside the tank. This relatively warm source of water is circulated on the second wall of evaporative cooling pads to enhance humidification. The water leaving the pads flows by gravity into a sump tank and is then pumped to the condensers. The temperature of the water in the sump tank is expected to be cooler than the water of the outside tank since it has been evaporatively cooled. Water leaving the condensers is then returned to the outside reservoir (Figure 4). Figure 4. Layout of the water circulation system 4. Greenhouse Inner Partitions and Greenhouse Instrumentation To force airflow through the cooling pads and condensers, 3 mm transparent acrylic partitions (baffles) were installed in the arcs of the greenhouse. Transparent material was used to minimize the interference with solar radiation coming in the greenhouse. The greenhouse was equipped with a Delta-T data logger (model DL2E, Delta-T Devices Ltd, UK) which monitored temperature of water and air temperatures and relative humidity in fourteen locations. In addition, solar radiation was recorded outside and inside from the greenhouse. All measurements were recorded with an hourly time interval. Air velocity was recorded with a digital anemometer (model HH31A, Omega Engineering Inc., US) in four cross-sections of the greenhouse (after

6 854 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt the first and second walls of evaporative cooling pads, and before/after the condensers). 5. Cooling pad and Condensers Configuration As mentioned earlier, the cooling pads and the condensers were mounted on wheels to investigate various configuration scenarios in the greenhouse. For this study, the condensers were installed 2 m away from the exhaust fans located at the back of the greenhouse. The second wall of evaporative cooling pads and the condensers frame were spaced 2 m apart. The fans, pumps and data logger were switched on for a period of one week in March The ability of the cooling pads to increase the relative humidity inside the greenhouse and the capability of the condensers to reduce the temperature of the air below its dew-point was assessed during this period. Estimation of the dew-point of the air entering the condensers was used to determine the temperature of the coolant required to condensate water. The dew-point was calculated using the following equations (ASHRAE [18]): d w 2 3 [ ln(p )] * [ ln(p )] * [ P ] t = * ln(p ) * + w where t d is the dew-point temperature in o C and P w is the water vapor partial pressure in kpa. The water vapor partial pressure P w is obtained by (ASHRAE [18]): w w (1) P w Φ * Pws = (2) 100 T, P and * *10 *T+ T *10 *T *10 *T *lnt P = 1000 * Exp (3) ws where is the relative humidity in %, P ws is the water vapor saturation pressure and P is the total pressure both in kpa and T is the absolute dry-bulb temperature in K. The absolute humidity (amount of water held in air) was also calculated for various points throughout the greenhouse as (ASHRAE [18]): d V = (4) where d v is the absolute humidity in kg/m 3, ω is the humidity ratio (kg of water/ kg of dry air) and v is the specific volume of the moist air mixture in m 3 /kg. The specific volume and the humidity ratio are calculated by (ASHRAE [18]): Plastic film

7 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt 855 and ( ) T * = (5) p P w = (6) P P w RESULTS AND DISCUSSION 1. Temperature and Relative Humidity through the First Wall of Evaporative Cooling Pads As expected, a reduction in air temperature and an increase in relative humidity was observed as air passed through the first layer of evaporative cooling pads (Figure 5). Temperature, o C Relative Humidity, % m before 1st pad 0.1 m after 1st pad 20 6: :00 6:00 18:00 6:00 18:00 6:00 18:00 6:00 18:00 6:00 18:00 6:00 18:00 6: Time (h) Figure 5. Temperature and relative humidity changes before and after the first wall of evaporative cooling pads

8 856 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt When the relatively hot and dry outside air is forced to flow through the first layer of wetted pads by the fans, it released part of its sensible heat to the water. Water used this sensible heat and heat from the surrounding (i.e., the water on evaporative cooling pads) to evaporate water from the pads. Thus, this resulted in a reduction in temperature and an increase in the relative humidity. It is interesting to note that maximum cooling occurs at midday when the relative humidity is at its lowest and hence evaporation rate at is highest (due to large vapor deficit). The cooling process is driven by the relative humidity of the incoming air. 2. Temperature and Relative Humidity Gradients through the Greenhouse One would expect the air temperature to increase as it is moving through the greenhouse. This is explained by the fact that the incoming shortwave solar radiations penetrates inside the greenhouse through the covering material, changes wavelength after reflection into longwave infrared radiation. Since the covering material is more transparent to shortwave than longwave the net balance results in trapped radiation that raises the temperature inside the greenhouse. This phenomenon has a positive impact on humidification and dehumidification in the greenhouse as it allows an increase in air capacity. Heat build-up was verified by placing three temperature sensors in the longitudinal axis of the greenhouse. Figure 6 shows the temperature gradient at three sequential locations throughout the greenhouse (0.1 m, 6 m and 12 m from the first layer of pads). At night, most readings were similar to each other due to the absence of solar radiation. On the other hand, the relative humidity of the air decreased as air moved away from the first pad. This decrease in relative humidity was due to the increase in air temperature that caused air to expand and thus, a potential to hold more moisture. This supported the use of a second wall of evaporative cooling pad to bring the air to saturation. Temperature, o C m after 1st pad 6 m from 1st pad 12 m from 1st pad Figure 6. Temperature gradient inside the greenhouse

9 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt Temperature and Relative Humidity through the Second Wall of Cooling Pads Increase in air temperature and decrease in relative humidity as air was moving through the greenhouse offered a great potential for air to hold more water vapor before the condensers justifying the construction of a second evaporating frame. Like the first layer of pads, there was a decrease in air temperature and an increase in the relative humidity as air was passing through the second layer of wetted pads. Temperature and relative humidity were measured 0.1 m before and after the second pad. The relative humidity after the second pad was usually greater than that measured after the first pad (Figure 7). Again, this strongly justifies the use of a second wall of evaporative cooling pads. However, the air after the second layer of pads was not always saturated. For instance, the relative humidity was always lower than 100% on the interval from 9:00 am to 6:00 pm. Ideally, the relative humidity should reach saturation at all times. This can be achieved by increasing water distribution efficiency on the pads. Saturation could also be achieved by changing air flow rate through the pads until the optimal flow rate (i.e., that gives the highest relative humidity) is obtained. In addition, high relative humidity could be enhanced by covering with reflective material the area of the greenhouse after the second layer of cooling pads. This would prevent temperature increase due to solar radiation and hence reduction in relative humidity m before 2nd pad 0.1 m after 2nd pad Relative Humidity, % Figure 7. Relative humidity increase between air entering and leaving the second wall of evaporative cooling pads 4. Absolute Humidity As mentioned earlier, the absolute humidity is an indicator of the amount of water held in that air. It can be observed that the first layer of evaporating pads was adding moisture to the coming air (Figure 8). Similarly, the absolute humidity after the second layer of pads was further increased. Figure 9 shows the difference between absolute humidity of the air entering and leaving the greenhouse expressed in terms of

10 858 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt evaporation rate. By integrating the curve over time, one can obtain the volume of water evaporated from the two evaporative cooling walls for a given period. For instance, it was found out that on average roughly 2.85 m 3 of water evaporated from the cooling pads each day Absolute humidity, kg/m Air entering greenhouse 0.1 m after 1st pad 0.1m after 2nd pad Figure 8. Absolute humidity gradient of air traveling through the greenhouse Evaporation rate from pads, kg/h Figure 9. Rate of water loss due to evaporation 5. Temperature of Water Flowing on the First and Second Pads The temperature of water leaving the pads was always lower than the temperature of the water arriving on top of the pads by up to 2 o C (Figure 10). This was due to the cooling effect of evaporation (i.e., evaporative cooling). Water flowing from both frames of the evaporating pads was collected in the sump tank. Water temperature in

11 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt 859 the sump tank was relatively cooler than that in the outside tank (Figure 11). Difference in water temperature between the outside and sump tanks reached 4.8 o C and the average difference was 3.1 o C. 28 Top of 1st pad Bottom of 1st pad 26 Temperature, oc Figure 10. Water temperature changes between top and bottom of first wall of evaporative cooling pads Outside tank Sump tank Temperature, oc Figure 11. Temperature differences between the outside tank and sump-tank (feeding the condenser) 6. Condensation Potential The dew-point of the air entering the condenser was calculated using Equation 1. Below this temperature, water vapor in the air condensate (ASHRAE [18]). Figure 12 shows the air dew-point temperature and the temperature of coolant flowing through the two cross flow condensers. It can be observed that condensers temperature was always lower than the dew-point temperature of the air with a maximum difference of

12 860 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt almost 4 o C. Even when including an uncertainty of ±2% in thermocouple readings in the calculations of dew-point to take into consideration the instrumental error, the temperature of the condenser remained lower than the dew-point temperature air. Thus, theoretically, water vapor condensation is possible. However, the tipping bucket gauge installed to record condensation rate did not registered outflow from the condensers. Formation of water droplets on the fins and tubes of the condensers were observed but only a small fraction of the droplets made their way to the gutter collecting the condensate. This is probably due to 1) high air speed through the condensers and 2) surface tension created between the water droplets and fins of the condenser. Air velocity was measure and averaged from nine points 0.25m after the first and second wall of evaporative cooling pads and the condensers. The airflow velocity through the two walls of cooling pads was 1.5 m/s. This flow velocity could be reduced as evaporative cooling through 0.1 m cellulose pads is optimal around 1.25 m/s (Wiersma et al. [19]). Air flow velocity through the two condensers was relatively high due to their small cross-sectional area (0.9 x 0.9 m). Although, the condensers were cold enough to condensate air moisture, this high airflow velocity may have left enough time to bring below dew-point only a fraction of the water molecules in vapor phase. In other words, air speed did not allow sufficient time for surface contact between the moist air and the condensers to reduce air temperature below saturation. Air velocity regulation trough the condensers should be investigated. It can be achieved by increasing the area of contact of the condensers and/or with varying fan speed. The fins design should also be looked at critically to avoid droplet entrapment by surface tension. 28 Air dew-point Coolant Temperature, o C Figure 12. Difference between dew-point temperature of air entering the condensers and temperature of the coolant in the condensers CONCLUSIONS A humidification-dehumidification system in a greenhouse at the Agricultural Experiment Station of Sultan Qaboos University was constructed. It was based on a Quonset design modified in order to include two humidifiers to increase water vapor

13 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt 861 inside the greenhouse. Two dehumidifiers (i.e., condensers) were constructed in the greenhouse after a second layer of evaporative cooling pads. Performance of the humidification and dehumidification processes was tested for a period of seven days. According to this preliminary test, several conclusions could be drawn. First, the second set of pads has met its construction objective by increasing the relative humidity before the condensers up to saturation most of the time. Evaporation from the two pads resulted in a reduction in water temperature up to 3 o C. Relatively cold water flowing out from the cooling pads was pumped through the condensers and used as a coolant. The temperature of the condensers was always lower than the dew-point temperature of air passing through them. Thus, condensation of water vapor on the condensers is possible. However, with the existing condenser design, condensation of water vapor was insufficient to result in measurable quantities. Low condensation can be attributed to the high air flow velocities through the condensers which did not allow enough time for surface contact between the air and the condensers and thus, obtaining the required reduction in air temperature to condense water vapor. Other factors, such as water droplets entrapment between condensers fins due to surface tension have also contributed to low condensation rate. Near condenser design and airflow velocity appears to be the bottle neck of the dehumification process. These aspects of the humidification-dehumidification system will be investigated in the near future. ACKNOWLEDGMENT This study was supported by Sultan Qaboos University project IG/AGR/BIOR/01/01. REFERENCES 1. Al-Mumtaz M. (2000). Water desalination in the Arabian Gulf region. In M. F. A. Goosen and W. H. Shayya (ed.), pp Water management, purification & conservation in arid climates. Volume 2: Water purification. Technomic Publishing Company, Inc., Pennsylvania 2. Abdel Rahman H. A.; Abdel Magid I. M. (1993). Water conservation in Oman. Water International, 18(2): Abdel-Rahman, H. A. (1996). Traditional systems application of modern irrigation techniques in the Sultanate of Oman. Agircultural Mechanization in Asia, Africa and Latin America 27(1): Al-Ajmi H. A.; Abdel-Rahman A. H. (2001). Water management intricacies in the Sultanate of Oman: The augmentation-conservation conundrum. Water International, 26(1): Norman W. R.; Shayya W. H.; Al-Ghafry A. S. (1998). Irrigation water costs and management practices among farms in Northern Oman, Agricultural Sciences, 3: 1-8.

14 862 Ninth International Water Technology Conference, IWTC9 2005, Sharm El-Sheikh, Egypt 6. Goosen M. F.; Sablani S. S.; Paton C.; Perret J.; Al-Nuaimi A.; Haffar I.; Al-Hinai H.; Shayya W. H. (2003). Solar energy desalination for arid coastal regions: development of a humidification dehumidification seawater greenhouse. Solar Energy, 75(5): Goosen M. F.; Al-Hinai H.; Sablani S. S. (2000a). Capacity building strategies for desalination: Activities, facilities and educational programs in Oman. In: Proc. EUROMED 2000: Desalination strategies in South Mediteranean Countries, Jerba, September Chaibi M. T. (2000). An overview of solar desalination for domestic and agricultural water needs in remote arid areas. Desalination, 127: Paton A. C.; Davis P. (1996). The seawater greenhouse for arid lands. In: Proc. Mediterranean conference on renewable energy sources for water production, June 10-12, Santorini. 10. Delyannis E.; Belessiotis E. (2000). Solar desalination for remote arid zones. In M. F. A. Goosen and W. H. Shayya (ed.), pp Water management, purification & conservation in arid climates, Volume 2: Water purification, Technomic Publishing Company, Inc., Pennsylvania. 11. Sablani S. S.; Goosen M. F.; Paton C; Shayya W. H.; Al-Hinai H. (2002). Simulation of the fresh Water production using a humidification-dehumidification seawater greenhouse. In: Proc. World renewable energy congress VII, June 29 - July 5, Cologne. 12. Bailey B. J.; Raoueche A. (1998). Design and performance aspects of a water producing greenhouse cooled by seawater. Acta Horticuturae, 458: Fujii T (1991). Theory of laminar film condensation. Springer-Verlag, New York, p Sauer H. J.; Howell R. H. (1983). Heat pump systems. John Wiley & Sons, Inc., New York, p Moran M. J.; Shapiro H. N. (1992). Fundamentals of engineering thermodynamics. 2nd Ed., John Wiley & Sons, Inc., New York. 16. Mangold D. W.; Bundy D. S.; Hellickson M. A. (1983). Psychrometrics. In M. A. Hellickson, J. N. Walker and S. J. Mich (ed.). Ventilation of agricultural structures. ASAE monograph. No.6. XY/N-1: Huang F. F. (1988). Engineering thermodynamics: Fundamentals and applications. 2nd Ed., Macmillan Publishing Company, New York, p ASHRAE (American Society of Heating, Refrigerating, and Air-conditioning Engineering) (2001). Psychrometrics. Fundamentals handbook (SI). New York. 19. Wiersma F.; Short T. H. (1983). Evaporative cooling. In M. A. Hellickson, J. N. Walker and S. J. Mich (Ed.). Ventilation of agricultural structures. ASAE monograph. No. 6. XY/N-1:

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES Third Southern African Solar Energy Conference 11 13 May 2015 Kruger National Park, South Africa SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES Shahmohamadi M., Shafii, M.B.and

More information

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes ME 410 - Mechanical Engineering Systems Laboratory Experiment 3 - Mass and Energy Balances in Psychrometric Processes Assist.Prof.Dr. Özgür BAYER, A-123 AIR-CONDITIONING (A/C) Goal: Control temperature

More information

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES THERMAL SCIENCE, Year 2011, Vol. 15, No. 2, pp. 467-475 467 EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES by Krishnasamy SENTHILKUMAR a* and Pss

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

Evaporative Cooling Applicability in the Middle East

Evaporative Cooling Applicability in the Middle East Evaporative Cooling Applicability in the Middle East Oxycom Fresh Air BV April 14th, 215 Abstract Oxycom developed various evaporative cooling solutions, either as standalone configurations or as combinations

More information

EXPERIMENTAL STUDY OF WATER DESALINATION BASED ON HUMIDIFICATION- DEHUMIDIFICATION PROCESS VIA HEAT PUMP

EXPERIMENTAL STUDY OF WATER DESALINATION BASED ON HUMIDIFICATION- DEHUMIDIFICATION PROCESS VIA HEAT PUMP EXPERIMENTAL STUDY OF WATER DESALINATION BASED ON HUMIDIFICATION- DEHUMIDIFICATION PROCESS VIA HEAT PUMP A. E. Tourab 1, Mohamed A. Teamah 2, Ahmed A. Hanafy 1, Wael M. EL-Maghlany 2 1 Arab Academy for

More information

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University Scientific Principals and Analytical Model Charcoal Cooler Lisa Crofoot MECH 425, Queens University 1.0 Scientific Principles Evaporative cooling is based on the principle that water requires heat energy

More information

Greenhouse Temperature Management

Greenhouse Temperature Management Greenhouse Temperature Management A.J. Both Assistant Extension Specialist Rutgers University Bioresource Engineering Dept. of Plant Biology and Pathology 20 Ag Extension Way New Brunswick, NJ 08901 both@aesop.rutgers.edu

More information

EXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING

EXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING EXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING Ayad T. Mustafa College of Engineering, Nahrain University, Jadiriya, Baghdad,

More information

Experimental Efficiency Investigation on Heat Recovery System Used in a Solar-Powered Desalination Process

Experimental Efficiency Investigation on Heat Recovery System Used in a Solar-Powered Desalination Process Energy Research Journal 3 (2): 27-36, 2012 ISSN 1949-0151 2012 doi:10.3844/erjsp.2012.27.36 Published Online 3 (2) 2012 (http://www.thescipub.com/erj.toc) Experimental Efficiency Investigation on Heat

More information

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University 2 Objectives Differentiate between dry air and atmospheric air. Define and calculate

More information

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement International Conference Passive and Low Energy Cooling 651 Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

More information

AR/IA/UP 241 Lecture 5: Psychrometrics

AR/IA/UP 241 Lecture 5: Psychrometrics Faculty of Architecture and Planning Thammasat University AR/IA/UP 241 Lecture 5: Psychrometrics Author: Asst. Prof. Chalermwat Tantasavasdi 1. Definition of Psychrometric Chart The word psychrometry is

More information

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made. Dryer Section All Paper Grades Press Release How can the efficiency of the T. Bock (Dipl.-Ing.), Manager Application & Technical Service, Heimbach GmbH & Co. KG, thomas.bock@heimbach.com I. Durniok (Dipl.-Ing.),

More information

ω = (1) Kirby S. Chapman Ph.D.

ω = (1) Kirby S. Chapman Ph.D. White Paper: Relative Humidity Impacts of the AirFloor System in the Built Environment Kirby S. Chapman Ph.D. kirby.chapman@scavengetech.com Introduction Relative humidity is specified as one of the seven

More information

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes

More information

SIMULATION OF HDH DESALINATION SYSTEM USING TILTED, TWO-PASS SOLAR AIR HEATER

SIMULATION OF HDH DESALINATION SYSTEM USING TILTED, TWO-PASS SOLAR AIR HEATER SIMULATION OF HDH DESALINATION SYSTEM USING TILTED, TWO-PASS SOLAR AIR HEATER A. A. Shabaneh 1, P. Gandhidasan 1, M. A. Antar 1* and H. Baig 2 1 Mechanical Engineering Department, KFUPM, shabaneh@kfupm.edu.sa,

More information

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011 Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage Kulkarni.R.K 1, Rajput S.P.S 2 1 SVPM College of Engineering, Malegaon(bk),

More information

HVAC (Heating, Ventilating, and Air Conditioning)

HVAC (Heating, Ventilating, and Air Conditioning) HVAC (Heating, Ventilating, and Air Conditioning) Gas vapor Mixtures The term vapor implies a gaseous state that is close to the saturation region of the substance, raising the possibility of condensation

More information

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering Session 2633 Development of a Psychrometric Test Chamber Michael J. Swedish Associate Professor Mechanical Engineering Department Milwaukee School of Engineering Acknowledgments The design of the Psychrometric

More information

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Experimental Study of Direct Contact Condensation of Steam on Water Droplets , July 1-3, 2015, London, U.K. Experimental Study of Direct Contact Condensation of Steam on Water Droplets Semra GUMRUK, Murat K. AKTAS Abstract Air or water cooled condensers are used to reduce the moisture

More information

CE311 Fall 2016 Mid-Term Exam 1

CE311 Fall 2016 Mid-Term Exam 1 Instructions 1.! Please solve the problems using the specified SI or IP system of units. 2.! Please show all of your calculations to get full credit and pay attention to assumptions. 3.! Neatly mark points

More information

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE Gutti Babagana, Kiman Silas and Mustafa B. G. Department of Chemical Engineering, University of Maiduguri, Borno,

More information

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure. 1 PSYCHROMETICS Psychrometry is the study of the characteristics of moist air. We will see soon that evaporation of moisture from the skin can have a significant impact on thermal comfort. The rate of

More information

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS Chainarong Chaktranond *, and Peachrakha Doungsong Department of Mechanical Engineering, Faculty of Engineering,

More information

Oxyvap Evaporative Cooling Applications

Oxyvap Evaporative Cooling Applications Oxyvap Evaporative Cooling Applications Oxycom Fresh Air BV March 9th, 2015 Abstract This paper shows two highly efficient applications of the Oxyvap direct evaporative cooling technology, developed by

More information

Solar Still - Improved Distillation

Solar Still - Improved Distillation Solar Still - Improved Distillation Herbert Weidner a Abstract: An analysis of the steam cycle in an humidification-dehumidification desalination system shows that reheating of the air can drastically

More information

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector International Conference on Mechanical, Industrial and Materials Engineering 2015 (ICMIME2015) 11-13 December, 2015, RUET, Rajshahi, Bangladesh Paper ID: ET-46 Experimental Investigation of a Hybrid Evacuated

More information

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE Journal of Sustainability Science and Management Volume 9 Number 1, June 2014: 150-155 ISSN: 1823-8556 Penerbit UMT PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE ARFIDIAN

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering July 2018 Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to

More information

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER Impact Factor (SJIF): 4.42 International Journal of Advance Research in Engineering, Science & Technology e-issn: 2393-9877, p-issn: 2394-2444 Volume 4, Issue 11, November-217 SOLAR HUMIDIFIER PATEL RONIT

More information

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator 18 R. Saidur et al./journal of Energy & Environment, Vol. 6, May 2007 Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator R. Saidur, M. A. Sattar, M.

More information

CE311 Fall 2016 Mid-Term Exam 1

CE311 Fall 2016 Mid-Term Exam 1 CE311 Fall 16 Mid-Term Exam 1 Name Instructions 1. Please solve the problems using the specified SI or IP system of units. 2. Please show all of your calculations to get full credit and pay attention to

More information

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle

More information

Week 4. Gas-vapor mixtures Air conditioning processes. ME 300 Thermodynamics II 1

Week 4. Gas-vapor mixtures Air conditioning processes. ME 300 Thermodynamics II 1 Week 4 Gas-vapor mixtures Air conditioning processes ME 300 Thermodynamics II 1 Today s Outline Gas-vapor mixtures Key definitions and measures ME 300 Thermodynamics II 2 Gas-vapor Mixtures At temperatures

More information

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel

More information

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area MMS DEZFOULI, SOHIF MAT, K.SOPIAN Solar Energy Research Institute (SERI, Universiti

More information

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008 Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Mehmet Kanoglu Copyright The McGraw-Hill Companies,

More information

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1 TECHNICAL NOTE ON EVAPORATIVE COOLING Renato Lazzarin, President of the IIR s Commission E1 Principles The air has a variable water content from 0 (dry air) to a maximum value (saturated air) that strongly

More information

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant Proceedings of the World Congress on Momentum, Heat and Mass Transfer (MHMT 16) Prague, Czech Republic April 4 5, 216 Paper No. ENFHT 111 DOI: 1.11159/enfht16.111 Experimental Investigation of a Multi

More information

Effect on air quality and flow rate of fresh water production in humidification and dehumidification system

Effect on air quality and flow rate of fresh water production in humidification and dehumidification system IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Effect on air quality and flow rate of fresh water production in humidification and dehumidification system To cite this article:

More information

Thermodynamics: Homework A Set 7 Jennifer West (2004)

Thermodynamics: Homework A Set 7 Jennifer West (2004) Thermodynamics: Homework A Set 7 Jennifer West (2004) Problem 1 Water is the working fluid in a Carnot vapor power cycle. Saturated liquid enters the boiler at a pressure of 18 MPa, and saturated vapor

More information

GRAPSI_DRAW DIGITAL PSYCHROMETRIC CHART

GRAPSI_DRAW DIGITAL PSYCHROMETRIC CHART GRAPSI_DRAW DIGITAL PSYCHROMETRIC CHART Daniela de C. Lopes 1,*, Evandro de C. Melo 1, José H. Martins 1, Luis Manuel N. Gracia 2, Adriana C. Guimarães 3 1 Department of Agricultural Engineering, Federal

More information

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY Xiaoyun Xie, Yidan Tang, Xiaoqin Yi, Shuanqiang Liu,Yi Jiang Department of Building Science and Technology,

More information

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Effect of Height Difference on The Performance of Two-phase Thermosyphon

More information

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER THERMAL SCIENCE: Year 2016, Vol. 20, No. 1, pp. 267-277 267 PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER by Nurettin YAMANKARADENIZ a, K. Furkan SOKMEN d, Salih COSKUN a*, Omer KAYNAKLI b,

More information

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump To cite this article: Yefeng Liu et al 2018 IOP

More information

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible

More information

Optimize Evaporative Cooler

Optimize Evaporative Cooler Frequently Asked Questions and Answers Contents regarding the Optimize Evaporative Cooler Technical 1 General Questions, Cooling Potential and Cooling Efficiency 2 Air velocity and pressure loss 3 Erection

More information

Available online Journal of Scientific and Engineering Research, 2017, 4(10): Research Article

Available online   Journal of Scientific and Engineering Research, 2017, 4(10): Research Article Available online www.jsaer.com, 2017, 4(10):305-311 Research Article ISSN: 2394-2630 CODEN(USA): JSERBR Low Cost Humidity/Temperature Calibration System Yasser A. Abdelaziz 1 Central Laboratories Department,

More information

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING DA Hindoliya and SC Mullick * Centre for Energy Studies, Indian

More information

Figure 1: Overview of CO 2 evaporator types

Figure 1: Overview of CO 2 evaporator types DESIGN CRITERIA FOR CO 2 EVAPORATORS Roland Handschuh Güntner Paper for GTZ Proklima, published in Natural Refrigerants sustainable ozone- and climatefriendly alternatives to HCFCs, April 2008. Introduction

More information

Residential Building Walls and Environment in Amman, Jordan

Residential Building Walls and Environment in Amman, Jordan Int. J. of Thermal & Environmental Engineering Volume 3, No. 2 (211) 1-7 Residential Building Walls and Environment in Amman, Jordan S. J. Sulaiman*, N. Beithou Department of Mechanical Engineering, Applied

More information

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA Ninth International IBPSA Conference Montréal, Canada August 15-18, 25 SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS Chaoqin Zhai 1, Xiaohong

More information

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates Purdue University Purdue e-pubs International High Performance Buildings Conference School of Mechanical Engineering 2014 Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for

More information

Optimizing Electric Humidifier Operation with an Air Side Economizer

Optimizing Electric Humidifier Operation with an Air Side Economizer Optimizing Electric Humidifier Operation with an Air Side Economizer Usama F. Shami, P.E. Senior Project Engineer Savage Engineering, Inc. Foster City, CA Abstract Air side economizer cycle is a control

More information

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM Humidity Control and Heating and Cooling Applications December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM Today s Discussion Discussion of cooling, heating and dehumidification

More information

Thermodynamics II Chapter 6 Mixtures & Psychrometry

Thermodynamics II Chapter 6 Mixtures & Psychrometry Thermodynamics II Chapter 6 Mixtures & Psychrometry Mohsin Mohd Sies Fakulti Kejuruteraan Mekanikal, Universiti Teknologi Malaysia Objectives Differentiate between dry air and atmospheric air. Define and

More information

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler International Journal of Thermal Technologies E-ISSN 2277 4114 2015 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Effect of Operating Parameters on the

More information

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Impact of indirect evaporative air cooler type on the performance of desiccant systems Impact of indirect evaporative air cooler type on the performance of desiccant systems Anna Pacak 1,*, Aleksandra Cichoń 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of Science and

More information

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings Melanie T. Fauchoux, PhD Student University of Saskatchewan http://www.engr.usask.ca/dept/mee melanie.fauchoux@usask.ca

More information

Comfort and health-indoor air quality

Comfort and health-indoor air quality Comfort and health-indoor air quality 1 The human body has a complicated regulating system to maintain the human body temperature constant most of the time, which is 98.6 F (36.9 C) regardless of the environmental

More information

Performance of an Improved Household Refrigerator/Freezer

Performance of an Improved Household Refrigerator/Freezer Performance of an Improved Household Refrigerator/Freezer D. O. Ariyo Department of Mechanical Engineering, School of Engineering, Federal Polytechnic, Offa, Nigeria Y. L. Shuaib-Babata Department of Mechanical

More information

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Brig Gen Md. Lutfor Rahman, Sumaiya Nawrin, Rasel A Sultan Department of Mechanical Engineering, Military Institute

More information

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM Proceedings of ASME FEDSM 3 4 th ASME_JSME Joint Fluids Engineering Conference Honolulu, Hawaii, USA, July 6-1, 23 MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING

More information

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection. Volume 5, Issue 1 CARRIER edesign SUITE NEWS Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC Equipment Selection A design challenge sometimes occurs when computing design loads using

More information

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations 43rd ANZSES Conference Solar 24, Denedin (NZ), 28.11.-3.11.5, CD Abstract Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations M., W. Saman, K. Vajen* Sustainable

More information

Practical Fundamentals of Heating, Ventilation and Air Conditioning (HVAC) for Engineers and Technicians

Practical Fundamentals of Heating, Ventilation and Air Conditioning (HVAC) for Engineers and Technicians Presents Practical Fundamentals of Heating, Ventilation and Air Conditioning (HVAC) for Engineers and Technicians Revision 11.2 Website: www.idc-online.com E-mail: idc@idc-online.com IDC Technologies Pty

More information

THE BEHAVIOR OF LEWIS NUMBER IN FINNED TUBE COOLING COILS UNDER HIGHLY MOIST INLET AIR CONDITIONS

THE BEHAVIOR OF LEWIS NUMBER IN FINNED TUBE COOLING COILS UNDER HIGHLY MOIST INLET AIR CONDITIONS International Journal of echnology (2016) 7: 1253-1259 ISSN 2086-9614 IJech 2016 HE BEHAVIOR OF LEWIS NUMBER IN FINNED UBE COOLING COILS UNDER HIGHLY MOIS INLE AIR CONDIIONS eerachai Howongsakun 1*, Somnuk

More information

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,

More information

Use of heat pump dehumidifiers on industrial drying of chili

Use of heat pump dehumidifiers on industrial drying of chili International Journal of Scientific and Research Publications, Volume 7, Issue 12, December 2017 105 Use of heat pump dehumidifiers on industrial drying of chili Abeyrathna R.M.R.D., Amaratunga K.S.P.

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS MASS BALANCES, PSYCHROMETRICS & HVAC 1 Copyright 2018. All rights reserved. How to use this book The exam specifications in effect since

More information

Dehumidification of Atmospheric Air for Water Production

Dehumidification of Atmospheric Air for Water Production Dehumidification of Atmospheric Air for Water Production Vinay M V 1, Suman A 2, Shadakshari R 3 U.G. Student, Department of Mechanical Engineering, Acharya Institute of Technology, Bangalore, Karnataka,

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System 4 th International Conference On Building Energy Environment Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System J Y Park H W

More information

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Available online   Journal of Scientific and Engineering Research, 2018, 5(11): Research Article Available online www.jsaer.com, 2018, 5(11):152-157 Research Article ISSN: 2394-2630 CODEN(USA): JSERBR Evaporation Cooling with Ceramics in Air-conditioning System Attila Szilágyi 1, István Farkas 2,

More information

Liquid Desiccant Air Conditioning Systems

Liquid Desiccant Air Conditioning Systems Liquid Desiccant Air Conditioning Systems High-Efficiency Industrial Dehumidification High-Efficiency External Air Dehumidification Energy-Efficient Heat Pump Drying For Industries Use Only www.ascsciences.com

More information

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 SAE Alternate Refrigerant Cooperative Research Program Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 To: Alternate Refrigerant Task Force Members From: Ward Atkinson

More information

Performance Analysis of a Solid Desiccant Air Dehumidifier

Performance Analysis of a Solid Desiccant Air Dehumidifier Performance Analysis of a Solid Desiccant Dehumidifier H. Mohamed Kamar *, N. Kamsah, K. N. A. Ku Shuib and N. A. Mufid Faculty of Mechancial Engineering, Universiti Teknologi Malaysia, 81310 Johor Bahru,

More information

Evaporative cooling process adaptive for Baghdad city climate

Evaporative cooling process adaptive for Baghdad city climate 35 Evaporative cooling process adaptive for Baghdad city climate A. Al-musaed Elegancy & Design, Denmark ABSTRACT Human has developed a board rang of passive cooling techniques in various parts of the

More information

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 3, ISSUE 4, APRIL 214 ISSN 2277-8616 Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates Ibrahim U. Haruna,

More information

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1 HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil

More information

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp.329 341, Article ID: IJMET_07_03_030 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=3

More information

Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar Chimney

Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar Chimney PLEA2005 - The 22 nd Conference on Passive and Low Energy Architecture. Beirut, Lebanon, 13-16 November 2005 1/6 Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar

More information

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area Sahil

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

Recent Advances in Energy, Environment and Economic Development

Recent Advances in Energy, Environment and Economic Development Experimental Investigation of Solar Hybrid Desiccant Cooling System in Hot and Humid Weather of Malaysia MM SALEHI DEZFOULI, Z HASHIM, MH RUSLAN, B BAKHTYAR, K SOPIAN, A ZAHARIM, S MAT, A RACHMAN, Solar

More information

Low GWP Refrigerants for Air Conditioning Applications

Low GWP Refrigerants for Air Conditioning Applications Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Low GWP Refrigerants for Air Conditioning Applications Samuel F. Yana Motta

More information

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment Technical Report An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment Hironobu Kurara, Custom Equipment Engineering Department 2, Custom Equipment

More information

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY 6 th Conference on Nuclear and Particle Physics 17-21 Nov. 2007 Luxor, Egypt A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY M. Abdel-Bary a, S. Abdel-Samad a,

More information

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube

More information

Optimisation of cooling coil performance during operation stage for improved humidity control

Optimisation of cooling coil performance during operation stage for improved humidity control Indoor Air 2008, 17-22 August 2008, Copenhagen, Denmark - Paper ID: 741 Optimisation of cooling coil performance during operation stage for improved humidity control S.C. Sekhar * and L.T. Tan National

More information

K.F. Fong *, C.K. Lee, T.T. Chow

K.F. Fong *, C.K. Lee, T.T. Chow Investigation on radiative load ratio of chilled beams on performances of solar hybrid adsorption refrigeration system for radiant cooling in subtropical city K.F. Fong *, C.K. Lee, T.T. Chow Building

More information

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump Available online at www.sciencedirect.com Procedia Engineering 8 (2011) 165 170 2 nd International Science, Social-Science, Engineering and Energy Conference 2010: Engineering Science and Management Hot

More information

Experimental study of air evaporative cooling process using microporous membranes

Experimental study of air evaporative cooling process using microporous membranes Experimental study of air evaporative cooling process using microporous membranes Sebastian Englart 1,* 1 Wrocław University of Science and Technology, Faculty of Environmental Engineering, Department

More information

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1. 568, Page Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors Jose N. FONSECA *, Rodrigo KREMER, Thiago DUTRA 2 EMBRACO, Research & Development Group, Joinville, Santa Catarina,

More information

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING H. Kotani, R. Satoh, T. Yamanaka Dept. of Architectural Engineering, School of Engineering, Osaka University, Osaka, Japan ABSTRACT The purpose

More information

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 4 (2013), pp. 441-448 International Research Publication House http://www.irphouse.com Experimental & Analytical

More information