CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1

Size: px
Start display at page:

Download "CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1"

Transcription

1 CHAPTER 14 MANDATORY REFERENCED STANDARDS AHAM DW-1-92 Household Electric Dishwashers Appliances AHAM DW-2PR-92 Plumbing Requirements for Household Dishwashers Appliances AHAM FWD-1-92 Food Waste Disposers Appliances AHAM FWD-2PR-89 Household Food Waste Disposer Units Appliances AHAM HLW-2 PR Plumbing Requirements for Home Laundry Equipment Appliances ANSI A (R93) Scheme for the Identification of Piping Systems Piping ANSI A ANSI A ANSI A ANSI A TABLE 14-1 Standards for Materials, Equipment, and Connections Where more than one standard has been listed for the same material or method, the relevant portions of all such standards shall apply. Ductile-Iron and Gray-Iron Fittings, 3 in. through 48 in. (75 mm through 1200 mm), for Water and Other Liquids (same as AWWA C110) Rubber-Gasket for Ductile-Iron Pressure Pipe and Fittings (same as AWWA C111) Ductile-Iron Pipe, Centrifugally Cast, for Water (same as AWWA C151) Ductile-Iron Compact Fittings, 3 in. through 24 in. (76 mm through 610 mm) and 54 in. through 64 in. (1400 mm through 1600 mm), for Water Service (same as AWWA C153) ANSI A Stainless Steel ASME B (R94 ANSI A [D] Vitrified Clay Pipe (now CSA A60.1M-76[C1992]) Piping, Non-Metallic ANSI A Accessible and Usable Buildings and Facilities Miscellaneous ANSI ASME A (R90) 2003 Backwater ANSI ASME A Trim for Water-Closet Bowls, Tanks, and Urinals Fixtures ANSI ASME A M-83 Roof Drains DWV Components ANSI A Load, Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile and Dimension Stone Installations Fixtures ANSI B Pipe Threads (Except Dryseal) (replaced by ASME B ) 241

2 Table 14-1 UNIFORM PLUMBING CODE ANSI ASME B (R94) Manually Operated Thermoplastic Gas Shutoff and in Gas Distribution Systems Fuel Gas ANSI/CSA LC Appliance Stands and Drain Pans Miscellaneous ANSI/ICC A Guidelines for Accessible and Usable Buildings and Facilities Miscellaneous ANSI Z Sanitation in Places of Employment (Table 4-1 Note 6) Miscellaneous ANSI Z a Gas Water Heaters Volume I Storage Water Heaters CSA 4.1a02 with Input Ratings of 75,000 Btu per Hour or Less (22 kw) Appliances ANSI Z Gas Water Heaters Volume III Storage, with Input Ratings Above 75,000 Btu per Hour, Circulating and Instantaneous Water Heaters Appliances ANSI Z Draft Hoods Appliances ANSI Z Gas-Fired Low-Pressure Steam and Hot-Water Boilers Appliances CSA 4.9a02 ANSI Z Manually Operated Gas for Appliances, Appliance Connector,, and Hose End ANSI Z Relief and Automatic Gas Shutoff Devices for CSA Hot-Water Supply Systems ANSI Z Connectors for Gas Appliances Appliances ANSI Z Quick-Disconnect Devices for Use with Gas Fuel Appliances CSA 6.9-M98 ANSI Z21.47b-02 Gas-Fired Central Furnaces ANSI Z21.5.1a-03 Gas Clothes Dryers Type 1 Clothes Dryer ANSI Z21.5.2a-03 Gas Clothes Dryers, Type 2 Clothes Dryers ANSI Z Gas-Fired Pool Heaters Swimming Pools CSA and Spas ANSI Z Connectors for Movable Gas Appliances Appliances CSA 6.16-M97 02 ANSI Z [D] Earthquake-Actuated Automatic Gas Shutoff Systems (withdrawn from ANSI June 1992) (replaced by ASCE 25) ANSI Z Line Pressure Regulators Fuel Gas CSA 6.22-M97 ANSI Z Cylinder Connection Devices Fuel Gas CSA 6.25-M97 ANSI Z Vented Gas-Fired Space-Heating Appliances Appliances CSA ANSI Z Certification - Third Party Certification Programs for Products, Processes, and Services ANSI Z Gas Food Service Equipment ANSI Z Plastic Bathtub Units Fixtures ANSI Z Plastic Shower Units Fixtures ANSI Z Plastic Lavatories Fixtures ANSI Z Plastic Water Closet Bowls and Tanks Fixtures ANSI Z Plastic Toilet (Water Closet) Seats Fixtures 242

3 MANDATORY REFERENCED STANDARDS Table 14-1 ANSI Z Plastic Sinks Fixtures ANSI Z Prefabricated Plastic Spa Shells Fixtures ANSI Z Plastic Bathtub Liners Fixtures ANSI Z Plastic Urinal Fixtures (Note 1) Fixtures ANSI Z National Fuel Gas Code (same as NFPA 54) Fuel Gas ANSI Z Emergency Eyewash and Shower Equipment Miscellaneous ARI Drinking Fountains and Self-Contained, Mechanically Refrigerated Drinking Water Coolers Appliances ASCE Earthquake Actuated Automatic Gas Shutoff Devices ASHRAE Energy Standard for Buildings Except Low-Rise Residential Buildings Miscellaneous ASME A (R02) Air Gaps in Plumbing Systems Piping ASME A Air Gap Fittings for Use with Plumbing Fixtures, Appliances, and Appurtenances Fixtures ASME A Stainless Steel Drainage Systems for Sanitary, Storm, and Chemical Applications, Above and Below Ground (Note 1) ASME A Macerating Toilet Systems and Related Components Fixtures ASME A (R98) Water Heater Relief Valve Drain Tubes Appliances (R02) ASME A Water Closet Personal Hygiene Devices Fixtures ASME A Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System Piping ASME A Point of Use and Branch Water Submetering Systems Miscellaneous ASME A M-97 (R02) Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use Fixtures ASME A Framing-Affixed Supports for Off-the-Floor Plumbing Fixtures Fixtures ASME A Floor and Trench Drains DWV Components ASME A Enameled and Epoxy Coated Cast Iron and PVC Plastic Sanitary Floor Sinks Fixtures ASME A Grease Interceptors Fixtures ASME A Grease Recovery Removal Devices Fixtures ASME A M Plumbing Fixture Fittings ASME A Plumbing Fixture Waste Fittings Fittings ASME A Backflow Protection Devices and Systems in Plumbing Fixture Kitchen, Lavatory, and Shower Fittings with Attached Hose Outlets ASME A Flexible Water Connectors Piping ASME A Deck Mounted Bath/Shower Transfer with Integral Backflow Protection ASME A M-94 Enameled Cast-Iron Plumbing Fixtures (R99) (Supplement ) Fixtures 243

4 Table 14-1 UNIFORM PLUMBING CODE ASME A M-98 Vitreous China Plumbing Fixtures Fixtures ASME A M Stainless Steel Plumbing Fixtures (Designed for Fixtures Residential Use) ASME A M-94 Porcelain-Enameled Formed Steel Plumbing Fixtures (R99) (Supplement ) Fixtures ASME A Trim for Water-Closet Bowls, Tanks, and Urinals Fixtures ASME A Hydraulic Performance Requirements for Water Closets and Urinals Fixtures ASME A M-95 Whirlpool Bathtub Appliances Fixtures ASME A M-87 Suction Fittings for Use in Swimming Pools, Wading Swimming Pools (R96) Pools, Spas, Hot Tubs, and Whirlpool Bathtub Appliances and Spas ASME A M-91 (R98) Non-Vitreous Ceramic Plumbing Fixtures Fixtures (R02) ASME A Dual Flush Devices for Water Closets Fixtures ASME A Wall Mounted and Pedestal Mounted Adjustable and Pivoting Lavatory and Sink Carrier System Fixtures ASME A Electrohydraulic Water Closets ASME A Six-Liter Water Closets Equipped with a Dual Flushing Device Fixtures ASME A Bathub/WhirlpoolBathtubs with Pressure Sealed Doors Fixtures ASME A Manufactured Safety VacuumRelease System (SVRS) for Fixtures Residential and Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems ASME A Qualification of Installers of High Purity Systems Swimming Pools & Spas Certification ASME A Qualification of Installers of Firestop Systems and Devices for Piping Systems Certification ASME A M-91[D] Floor Drains (Note 1) (replaced by ASME A ) DWV Components ASME A M-85 (R01) Hydrants for Utility and Maintenance Use (Note 1) ASME A M-84[D] Water Hammer Arresters (cancelled) Piping ASME A M-91 (R98) Cleanouts (Note 1) DWV Components (R02) ASME B (R92) (R01) Pipe Threads, General Purpose, Inch ASME B (R03) Dryseal Pipe Threads, Inch (R82/91/98) ASME B Cast-Iron Pipe Flanges and Flanged Fittings, Classes 25, 125, 250, and 800 ASME B Malleable-Iron Threaded Fittings ASME B Gray Iron Threaded Fittings (Includes Revision Services) ASME B Pipe Flanges and Flanged Fittings ASME B Iron Threaded Drainage Fittings (Note 1) ASME B (R94) Cast Bronze Threaded Fittings, Classes 125 and 250 Piping, Copper Alloy 244

5 MANDATORY REFERENCED STANDARDS Table 14-1 ASME B Cast Copper Alloy Solder Joint Pressure Fittings (Note 1) Piping, Copper Alloy ASME B Nonmetallic Flat Gaskets for Pipe Flanges ASME B Wrought Copper and Copper Alloy Solder Joint Pressure Fittings Alloy Piping, Copper Alloy ASME B Cast Copper Alloy Solder Joint Drainage Fittings DWV Alloy Piping, Copper Alloy ASME B Cast Copper Alloy Pipe Flanges and Flanged Fittings Alloy Piping, Copper Alloy ASME B Cast Copper Alloy Fittings for Flared Copper Tubes Alloy Piping, Copper Alloy ASME B ASME B [D] ASME B Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings DWV Alloy (Note 1) Cast Copper Alloy Solder Joint Fittings for Solvent Drainage Systems Alloy (discontinued) Manually Operated Metallic Gas for Use in Gas Piping Systems up to 125 psig Piping, Copper Alloy Piping, Copper Alloy ASME B Flanged, Threaded, and Welding End ASME B (R94) ASME B Large Metallic for Gas Distribution (Manually Operated, NPS 2-1/2 to 12, 125 psig Maximum) Pipe Unions, Malleable Iron Threaded (Includes Revision Services) ASME B Large Diameter Steel Flanges ASME B Wrought Copper and Copper Alloy Braze-Joint Pressure Fittings Piping, Copper Alloy ASME B36.10M Welded and Seamless Wrought Steel Pipe ASME Section IV Rules for Construction of Heating Boilers Miscellaneous ASME Section VIII Rules for Construction of Pressure Vessels Miscellaneous ASME Section IX Welding and Brazing Procedures, Welders, Brazers, and Welding and Brazing Operators Certification ASSE Pipe Applied Atmospheric-Type Vacuum Breakers Backflow Protection ASSE Anti-Siphon Fill (Ballcocks) for Gravity Water Closet Flush Tanks Backflow Protection ASSE Water Pressure Reducing ASSE Backflow Prevention Requirements for Commercial Dishwashing Machines Backflow Protection ASSE Water Heater Drain ASSE Residential Use Dishwashers Appliances ASSE Home Laundry Equipment Appliances ASSE Household Food Waste Disposer Units Appliances ASSE Commercial Food Waste Grinder Units Appliances ASSE Water Hammer Arresters Piping ASSE Hose-Connection Vacuum Breakers Backflow Protection 245

6 Table 14-1 UNIFORM PLUMBING CODE ASSE Backflow Prevention with Intermediate Atmospheric Vent Backflow Protection ASSE Reduced Pressure Principle Backflow Preventers and Reduced Backflow Protection Pressure Fire Protection Principle Backflow Preventers ASSE Hand-Held Showers Fixtures ASSE Double-Check Backflow Prevention Assembly Assemblies Backflow Protection and Double Check Fire Protection Backflow Prevention Assemblies ASSE ASSE Individual, Thermostatic Pressure Balancing and Combination Pressure Balancing and Thermostatic Control for Individual Fixtures Fittings Temperature Actuated Mixing for Hot Water Distribution Systems ASSE Trap Seal Primer, Water Supply Fed ASSE Vacuum Breaker Wall Hydrant, Freeze-Resistant Automatic Draining Type Backflow Protection ASSE Pressure Vacuum Breaker Assembly Backflow Protection ASSE Drains Air Gaps for Domestic Dishwasher Applications Backflow Protection ASSE Backflow Prevention for Beverage Dispensing Equipment Backflow Protection ASSE Hot Water Dispensers, Household Storage Type, Electrical Appliances ASSE Dual Check Valve Backflow Preventers Backflow Prevention ASSE Diverters for Plumbing Faucets with Hose Spray, Anti-Siphon Type, Residential Applications ASSE [D] Automatic Flow Controllers (discontinued) ASSE Dual Check Valve Type Backflow Preventers for Carbonated Beverage Dispensers Post Mix Types ASSE [D] Fixed Flow Restrictors (discontinued) Piping Backflow Protection ASSE Laboratory Faucet Backflow Preventer Backflow Protection ASSE Pressurized Flushing Devices (Flushometers) for Plumbing Fixtures Backflow Protection ASSE Trap Seal Primer Devices-Drainage Types and Electronic DWV Components Design Types ASSE Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies Backflow Protection ASSE Double Check Detector Fire Protection Backflow Backflow Protection Prevention Assemblies ASSE Air Admittance for Plumbing Drainage Systems- Stack Type Devices ASSE Performance Requirements for Individual and Branch Type Air Admittance for Sanitary Drainage Systems ASSE Hose Connection Backflow Preventers Backflow Protection 246

7 MANDATORY REFERENCED STANDARDS Table 14-1 ASSE Chemical Dispensing Systems Backflow Protection ASSE Spill Resistant Vacuum Breakers Backflow Protection ASSE Freeze Resistant Sanitary Yard Hydrants with Backflow Backflow Proctection Protection ASSE Outdoor Enclosures for Backflow Prevention Assemblies Backflow Proctection ASSE Temperature Actuated Flow Reduction (TAFR) for Individual Fixture Fittings ASSE Individual Pressure Balancing In-Line for Individual Fixture Fittings (Note 9) ASSE 1069 Automatic Temperature Control Mixing ASSE Water Temperature Limiting Devices ASSE 1072 Floor Drain Trap Seal Protection Device ASSE Series ASSE Professional Qualification Standard for Backflow Prevention Assembly Testers, Repairers, and Surveyors Professional Qualification Standard for Medical Gas Systems Installers, Inspectors, and Verifiers, Maintenance Personnel and Instructors Backflow Protection Certification ASTM A Ferritic Malleable Iron Castings ASTM A Gray Iron Castings ASTM A Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded, and Seamless ASTM A Cast-Iron Soil Pipe and Fittings (Note 1) ASTM A (R01) Gray Iron Castings for, Flanges, and Pipe Fittings ASTM A 197M-2000 Cupola Malleable Iron (Metric) ASTM A a 03 Seamless and Welded Austenitic Stainless Steel Pipes ASTM A Ductile-Iron Pressure Pipe ASTM A Corrosion-Resistant High-Silicon Iron Castings (Metric) ASTM A (R-99 e1 ) Ductile Iron Castings ASTM A 653M-2001a 03 Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process ASTM A Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples ASTM A a 02 High-Silicon Iron Pipe and Fittings (Note 1) ASTM A e1 04 Hubless Cast-Iron Soil Pipe and Fittings for Sanitary and Storm Drain Waste and Vent Piping Applications ASTM B 29-92(R97) 03 Refined Lead ASTM B Solder Metal (Note 4) ASTM B e1 Seamless Copper Pipe, Standard Sizes Piping, Copper Alloy 247

8 Table 14-1 UNIFORM PLUMBING CODE ASTM B e1 Seamless Red Brass Pipe, Standard Sizes Piping, Copper Alloy ASTM B Seamless Copper Tube Piping, Copper Alloy ASTM B e1 03 Seamless Copper Water Tube Piping, Copper Alloy ASTM B Seamless Brass Tube (Metric) Piping, Copper Alloy ASTM B Copper Sheet, Strip, Plate, and Rolled Bar Miscellaneous ASTM B ASTM B e1 03 General Requirements for Wrought Seamless Copper Copper-Alloy Tube Seamless Copper Tube for Air Conditioning and Refrigeration Field Service Piping, Copper Alloy Piping, Copper Alloy ASTM B Threadless Copper Pipe, Standard Sizes Piping, Copper Alloy ASTM B Copper Drainage Tube (DWV) Piping, Copper Alloy ASTM B Copper Sheet and Strip for Building Construction Miscellaneous ASTM B Welded Copper Tube Piping, Copper Alloy ASTM B Copper Alloy Sand Casting for General Applications (Note 5) Piping, Copper Alloy ASTM B e1 (R03) Welded Brass Tube Piping, Copper Alloy ASTM B [D] Seamless and Welded Copper Distribution Tube (Type D) Piping, Copper Alloy (discontinued) ASTM B [D] Welded Copper Alloy UNS C21000 Water Tube (discontinued 1994) Piping, Copper Alloy ASTM B Brass, Copper, and Chromium-Plated Pipe Nipples Piping, Copper Alloy ASTM B [D] Welded Copper Water Tube (discontinued 1994) Piping, Copper Alloy ASTM B e1 Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Alloy Tube ASTM B Seamless Copper Tube for Medical Gas Systems Piping, Copper Alloy ASTM B Making Capillary by Soldering of Copper and Copper Alloy Tube and Fittings ASTM C Concrete Sewer, Storm Drain, and Culvert Pipe Piping, Non-Metallic ASTM C Asbestos-Cement Pressure Pipe Piping, Non-Metallic ASTM C Concrete Drain Tile Piping, Non-Metallic ASTM C Compression for Vitrified Clay Pipe and Fittings ASTM C (R02) Asbestos-Cement Nonpressure Sewer Pipe (Notes 6 and 7) Piping, Non-Metallic ASTM C for Circular Concrete Sewer and Culvert Pipe, Using Rubber Gaskets ASTM C Precast Reinforced Concrete Manhole Sections Miscellaneous ASTM C Rubber Gaskets for Cast-Iron Soil Pipe and Fittings (Note 1) 248

9 MANDATORY REFERENCED STANDARDS Table 14-1 ASTM C Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated Piping, Non-Metallic ASTM C ASTM C ASTM C ASTM C e1 03 ASTM C ASTM C ASTM C Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications (Note 1) Flexible Transition Couplings for Underground Piping Systems Shielded Couplings Joining Hubless Cast-Iron Soil Pipe and Fittings Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste, and Vent (DWV); Sewer; Sanitary; and Storm Plumbing Systems for Above and Below Ground Heavy Duty Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings Piping, Non-Metallic ASTM D a Specification for Fuel Oil Miscellaneous ASTM D Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Sch. 40 and 80 ASTM D Poly(Vinyl Chloride) (PVC) Plastic Pipe, Sch. 40, 80, and 120 ASTM D (R00) Rubber O-rings for Asbestos-Cement Pipe ASTM D Polyethylene (PE) Plastic Pipe, Sch. 40 ASTM D [D] ASTM D ASTM D Polypropylene Plastic Molding and Extrusion Materials (replaced by ASTM D 4101) Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings Polyethylene (PE) Plastic Pipe, (SDR-PR) Based on Controlled Inside Diameter ASTM D Poly(Vinyl Chloride)(PVC) Pressure-Rated Pipe (SDR Series) ASTM D Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) ASTM D ASTM D ASTM D ASTM D [D] Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications Polyethylene (PE) Plastic Pipe, Sch. 40 and 80 (Based on Controlled Outside Diameter) Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Sch. 80 (Note 1) Threaded Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 80 (discontinued 1986) 249

10 Table 14-1 UNIFORM PLUMBING CODE ASTM D Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Sch. 40 (Note 1) ASTM D Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Sch, 80 (Note 1) ASTM D a ASTM D [D] Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings (Sch. 40) Socket-Type Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 80 (discontinued 1986) ASTM D a 03b Thermoplastic Gas Pressure Pipe Tubing and Fittings (Note 1) ASTM D Reinforced Epoxy Resin Gas Pressure Pipe and Fittings ASTM D a 02 Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems ASTM D Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe (Note 1) ASTM D ASTM D ASTM D a e1 Practice for Heating Fusion Joining of Polyolefin Pipe Fittings (Note 1) Acrylonitrile-Butadiene-Styrene (ABS) Sch.40 Plastic Drain, Waste, and Vent Pipe and Fittings (Note 1) Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings ASTM D a (R03) for IPS PVC Pipe Using Solvent Cement ASTM D Acrylonitrile-Butadiene-Styrene (ABS) and Poly(Vinyl Chloride) (PVC) Composite Sewer Piping ASTM D a 03 Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings (Note 1) ASTM D Polyethylene (PE) Plastic Tubing ASTM D e1 [D] Poly(Vinyl Chloride) (PVC) Plastic Tubing (discontinued 1991) ASTM D a ASTM D Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings (Note 1) Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution Systems ASTM D (R02) ASTM D ASTM D [D] Making Solvent-Cemented with Poly(Vinyl Chloride) (PVC) Pipe and Fittings Filament-Wound Fiberglass (Glass-Fiber-Reinforced Thermosetting Resin) Pipe Type PSP Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings (discontinued 1989) ASTM D Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings ASTM D a Polyethylene(PE) Plastic Pipe (DR-PR) (Based on Controlled Outside Diameter) 250

11 MANDATORY REFERENCED STANDARDS Table 14-1 ASTM D [D] Poly(Vinyl Chloride) (PVC) Plastic Line Couplings (discontinued 1986) ASTM D (R02) ASTM D Solvent Cements for Styrene-Rubber (SR) Plastic Pipe and Fittings Solvent Cements for Transition, Acrylonitrile-Butadiene- Styrene (ABS) and Poly(Vinyl Chloride (PVC) Non-Pressure Piping Components ASTM D for Plastic Pressure Pipes Using Flexible Elastomeric Seals ASTM D [D] Flaring Polyolefin Pipe and Tubing (discontinued) ASTM D a (R03) ASTM D [D] ASTM D ASTM D ASTM D for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals Perforated Styrene-Rubber (SR) Plastic Drain Pipe (discontinued 1989) Drain, Waste, and Vent (DWV) Plastic Fittings Patterns (Note 1) Rigid Acrylonitrile-Butadiene-Styrene (ABS) Materials for Pipe and Fittings Chlorinated Polyethylene (CPE) Sheeting for Concealed Water-Containment Membrane Fixtures ASTM D b Propylene Plastic Injection and Extrusion Materials Miscellaneous ASTM D (R01) ASTM D (R03) Poly(Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-Containment Membrane Determining the Performance of Oil/Water Separators Subjected to Surface Run-Off Fixtures Fixtures ASTM E b Surface Burning Characteristics of Building Materials Miscellaneous ASTM E a Fire Tests of Building Construction and Materials Miscellaneous ASTM E Fire Tests of Through-Penetration Fire Stops Miscellaneous ASTM F (R99) Safe Handling of Solvent Cements, Primers, and Cleaners Used for Joining Thermoplastic Pipe and Fittings ASTM F Corrugated polyethylene (PE) Tubing and Fittings ASTM F a 02 ASTM F ASTM F e1 ASTM F e1 Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings (Note 1) Threaded Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Sch. 80 Socket-Type Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Sch. 40 Socket-Type Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Sch

12 Table 14-1 UNIFORM PLUMBING CODE ASTM F Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe, Sch. 40 and 80 ASTM F ASTM F e1 [D] ASTM F ASTM F ASTM F ASTM F a 02 Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) Bell-End Chlorinated Poly(Vinyl Chloride) (CPVC) Pipe, Schedule 40 (discontinued 1987) Thermoplastic Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR) Schedule 40 and Schedule 80 Solvent Cements for Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe and Fittings Acrylonitrile-Butadiene-Styrene (ABS) Sch. 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core, (Note 1) Primers for Use in Solvent Cement of Poly(Vinyl Chloride) (PVC) Plastic Pipe and Fittings ASTM F Large Diameter Corrugated Polyethylene Tubing and Fittings ASTM F Polyethylene (PE) Plastic Pipe (SDR-PR) (Based on Outside Diameter) ASTM F a Type PS-46 and Type PS-115 Poly(Vinyl Chloride) (PVC) Plastic Gravity Flow Sewer Pipe and Fittings (Note 1) ASTM F Poly(Vinyl Chloride) (PVC) Profile Gravity Sewer Pipe and Fittings Based on Controlled Inside Diameter ASTM F Smoothwall Polyethylene (PE) Pipe for Use in Drainage and Waste Disposal Absorption Fields ASTM F e1 03a Crosslinked Polyethylene (PEX) Tubing ASTM F e1 02a Crosslinked Polyethylene (PEX) Plastic Hot- and Cold-Water Distribution Systems ASTM F e1 Coextruded Poly(Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core ASTM F a Polyethylene (PE) Large Diameter Profile Wall Sewer and Drain Pipe ASTM F a 03 ASTM F ASTM F a 03 Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe with a Smooth Interior and Fittings Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-Al-PEX) Pressure Pipe ASTM F a 03 Polyethylene/Aluminum/Polyethylene (PE-Al-PE) Composite Pressure Pipe ASTM F Pressure-Rated Composite Pipe and Fittings for Elevated Temperature Service 252

13 MANDATORY REFERENCED STANDARDS Table 14-1 ASTM F Gasketed Mechanical Couplings for Use in Piping Applications ASTM F ASTM F (R03) Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP) ASTM F Metal Insert Fittings with Copper Crimp Ring for SDR 9 Crosslinked Polyethylene (PEX) Tubing ASTM F ASTM F e1 ASTM F a ASTM F e1 03 ASTM F ASTM F ASTM F e1 02 ASTM F e1 02 ASTM F Poly(Vinyl Chloride) (PVC) Drainage and DWV Fabricated Fittings, Schedule 40 Plastic Mechanical Fitting for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing Metallic Mechanical Fittings for Use on Outside Diameter Controlled Thermoplastic Gas Distribution Pipe and Tubing Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-Linked Polyethylene (PEX) Tubing Metal Cold Flare Compression Fittings with Disc Springs for Crosslinked Polyethylene (PEX) Tubing Special Engineered Fittings or Appurtenances for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly(Vinyl Chloride) (CPVC) Systems Factory Assembled Anodeless Riser and Transition Fitting in Polyethylene (PE) Fuel Gas Distribution Systems Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe Cold-Expansion Fittings With Metal Compression Sleeves for Cross-Linked Polyethylene (PEX) Pipe ASTM F Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX)Tubing to Metal Insert Fittings ASTM F Plastic Insert Fittings Utilizing a Copper Ring for SDR 9 Cross-Linked Polyethylene (PEX) Tubing ASTM F Flexible pre-insulated Piping ASTM F Cross-LinkedPolyethylene/Aluminum/Cross-Linked Polyethylene TubingOD Controlled SDR 9 AWS A Filler Metals for Brazing and Braze Welding AWS B Brazing Procedure and Performance Qualification Certification AWWA C Ductile-Iron and Gray-Iron Fittings, 3 in. through 48 in. (75 mm through 1200 mm), for Water and Other Liquids (same as ANSI A ) 253

14 Table 14-1 UNIFORM PLUMBING CODE AWWA C AWWA C AWWA C AWWA C203-91a 02 AWWA C AWWA C AWWA C Rubber-Gasket for Ductile-Iron Pressure Pipe and Fittings (same as ANSI A ) Ductile-Iron Pipe, Centrifugally Cast, for Water (same as ANSI A ) Ductile-Iron Compact Fittings, 3 in. through 24 in. (76 mm through 610 mm) and 54 in. through 64 in. (1400 mm through 1600 mm), for Water Service (same as ANSI A ) Coal-Tar Protective Coatings and Linings for Steel Water Pipelines Enameled and Tape Hot Applied Fusion-Bonded Epoxy Coating for the Interior and Exterior of Steel Water Pipelines Extruded Polyolefin Coatings for the Exterior of Steel Water Pipelines Piping Asbestos-Cement Distribution Pipe, 4 in. through 16 in. (100 mm through 400 mm) for Water Distribution Systems Piping, Non-Metallic AWWA C Gate for Water and Sewerage Systems AWWA C Rubber-Seated Butterfly AWWA C Ball, 6 in. through 48 in. (150 mm through 1200 mm) AWWA C Double Check Valve Backflow-Prevention Assembly Backflow Protection AWWA C Reduced-Pressure Principle Backflow-Prevention Assemblies Backflow Protection AWWA C Grooved- and Shouldered-Type AWWA C AWWA C AWWA C AWWA C Poly(vinyl Chloride) (PVC) Pressure Pipe, 4 in. through 12 in., for Water Distribution Polyethylene (PE) Pressure Pipe and Tubing, 1/2 in. (13 mm) through 3 in. (76 mm), for Water Service Polybutylene (PB) Pipe, Tubing, and Fittings, 1/2 in. Through 3 in., for Water Poly Chloride (PVC) Pressure Fittings for Water - 4in. Through 8 in. (100mm through 200mm) CISPI CISPI HSN-85[D] CISPI Hubless Cast-Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications (Note 1) Neoprene Rubber Gaskets for Hub and Spigot Cast- Iron Soil Pipe and Fittings (discontinued) Couplings for Use in Connection with Hubless Cast-Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications CSA 3-92 U.S. Requirements for Excess Flow CSA A Concrete Pipe and Manhole Sections Piping CSA B45-02 Plumbing Fixtures Fixtures 254

15 MANDATORY REFERENCED STANDARDS Table 14-1 CSA B Ceramic Plumbing Fixtures Fixtures CSA B Enameled Cast-Iron Plumbing Fixtures Fixtures CSA B Porcelain-Enameled Steel Plumbing Fixtures Fixtures CSA B Stainless Steel Plumbing Fixtures Fixtures CSA B Plastic Plumbing Fixtures Fixtures CSA B Macerating Systems and Related Components DWV Components CSA B Hydromessage Bathtubs Fixtures CSA B Vacuum Breaker, Atmospheric Type (AVB) Backflow Protection CSA B Vacuum Breaker, Pressure Type (PVB) Backflow Protection CSA B Vacuum Breaker, Hose Connection Type (HCVB) Backflow Protection CSA B Vacuum Breakers, Hose Connection Dual Check Type (HCDVB) Backflow Protection CSA B Vacuum Breakers, Hose Connection Type with Automatic Backflow Protection Drainage Feature (HCVB) CSA B Backflow Preventers, Reduced Pressure Principle Type (RP) Backflow Protection CSA B Backflow Preventers, Reduced Pressured Principle Type Backflow Protection for Fire System (RPF) CSA B Backflow Preventers, Double Check ValveType (DVCA) Backflow Protection CSA B Backflow Preventers, Double Check Valve Type for Fire Backflow Protection Systems (DVCAF) CSA B Vacuum Preventers, Laboratory Faucet Type (LFVB) Backflow Protection CSA B Plumbing Fittings CSA B Polyethylene Pipe, Tubing, and Fittings for Cold Water Pressure Services CSA B Crosslinked Polyethylene (PEX) Tubing Systems for Pressure Applications CSA B Polyethylene/Aluminum/Polyethylene Composite Pressure-Pipe Systems CSA B Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Fittings Composite Pressure-Pipe Systems CSA B Polyolefin Laboratory Drainage Systems CSA B Plastic Drain and Sewer Pipe and Pipe Fittings CSA B PVC Sewer Pipe and Fittings (PMS Type) CSA B (R98) Groove and Shoulder Type Mechanical Pipe Couplings Fittings CSA B Prefabricated Self-Sealing Roof Vent Flashing Fittings CSA B Water Pressure Reducing for Domestic Water Supply Systems CSA F Solar Domestic Hot Water Systems (Liquid to Liquid Heat Trans CSA G Corrugated Steel Pipe Products Fittings FS A-A-51145C Flux, Soldering, Non-Electronic, Paste, and Liquid FS K Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings FS M Acrylonitrile-Butadiene-Styrene (ABS) Sch. 40 Plastic Drain, Waste, and Vent Pipe and Fittings FS O-F-499D-85 Flux Brazing 255

16 Table 14-1 UNIFORM PLUMBING CODE FS O-F-506C-72[D] Flux, Soldering (discontinued) FS OO-L-201 f-70 Shower Pans Sheet Lead, Grade B (4 lb. min.) Miscellaneous FS QQ-R-571C-69[D] Copper and Nickel Alloys (Rods) (discontinued) Miscellaneous FS TT-S [D] Seal Compound Pipe Joint and Thread (discontinued) FS WW-P 325B-76 Lead Pipe and Bends Piping FS WW-P-541-E-90 Plumbing Fixtures, General Specification Fixtures Gen FS WW-U-516A-74(b) Copper Alloy (Bronze) Unions Piping, Copper Alloy FS WW-V-54d[D] Valve, Gate, Bronze (125, 150, and 200 lb., Screwed Flange, Solder-End, for Land Use) (discontinued) FS WW-V-58b, Gate, Cast Iron (125 and 250 lb), Screwed and Flanged (for Land Use) IAPMO PS a 03c Prefabricated Septic Tanks DWV Components IAPMO PS a [D] Cast Brass and Tubing P-Traps (replaced by ASME A ) Piping, Copper Alloy IAPMO PS e1 03a Drains for Prefabricated and Precast Showers Fixtures IAPMO PS 7-84 [D] Tubing Trap Wall Adapters (discontinued) DWV Components IAPMO PS 9-84 [D] Diversion Tees and Twin Waste Elbows (discontinued) DWV Components IAPMO PS Flexible Metallic Water Connectors Piping IAPMO PS a e1 Subdrains for Built-Up Shower Pans Fixtures IAPMO PS Dishwasher Drain Air Gaps Backflow Protection IAPMO PS Fittings for Joining Polyethylene Pipe for Water Service and Yard Piping IAPMO PS Backflow Prevention Assemblies Backflow Protection IAPMO PS 33-00a Flexible PVC Hose for Pools, Hot Tubs, Spas and Jetted Bathtub IAPMO PS Polyethylene Encasement Sleeve for Potable Water Pipe and Tubing Piping IAPMO PS Lead-Free Sealing Compounds for Threaded IAPMO PS Black Plastic PVC or PE Pressure-Sensitive Corrosion Preventive Tape Piping IAPMO PS ABS and PVC Backwater DWV Components 256

17 MANDATORY REFERENCED STANDARDS Table 14-1 IAPMO PS Anodeless Transition Riser for Use with PVC Gas Yard Piping Fuel Gas IAPMO PS Copper and Other Metallic Roof/Deck/Balcony Drains DWV Components IAPMO PS Pipe Alignment and Secondary Support Systems Piping IAPMO PS Cushioned Bathtubs and Whirlpool Bathtub Appliances Fixtures IAPMO PS [D] Bathtub Three-Way Diverter with Backflow Protection (replaced by ASME A ) IAPMO PS e1 Plastic Roof Drains DWV Components IAPMO PS [D] Material Safety Data Verification for Plumbing Products Miscellaneous (replaced by NSF 61) IAPMO PS Backflow Prevention Requirements for Fixture Fittings with Hose Connected Singular Moveable Outlets IAPMO PS Dual Flush Devices For Water Closets Fixtures IAPMO PS Plastic and Metallic Expansion Backflow Protection IAPMO PS 52-99e1 Sumps and Sewage Ejector Tanks DWV Components IAPMO PS Grooved Mechanical Pipe Couplings and Grooved End Fittings IAPMO PS a 03a Metallic and Plastic Utility Boxes Miscellaneous IAPMO PS Bathwaste Strainer Drains Fixtures IAPMO PS PVC Hydraulically Actuated Diaphragm Type Water Control IAPMO PS [D] Supports for Off-the-Floor Plumbing Fixtures With or Without Concealed Tanks (replaced by ASME A ) Fixtures IAPMO PS Septic Effluent and Waste Water Diverter DWV Components IAPMO PS Sewage Holding Tank Containing Sewage Ejector Pump for Direct-Mounted Water Closet IAPMO PS Fabricated Stainless Steel Security Water Closets Fixtures IAPMO PS 62-93[D] Enameled Cast-Iron Sanitary Floor Sinks (replaced Fixtures by ASME A ) DWV Components IAPMO PS 63-99a 02 Plastic Leaching Chambers DWV Components IAPMO PS Pipe Flashings Piping IAPMO PS Air Gap Units for Water Conditioning Equipment Installation Backflow Protection IAPMO PS Dielectric Waterway Fittings Piping IAPMO PS Early-Closure Replacement Flappers or Early-Closure Replacement Flapper With Mechanical Assemblies Fixtures IAPMO PS a Plastic Bathwaste and Overflow Assemblies IAPMO PS [D] Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors Fixtures IAPMO PS [D] 02 Electronic-Controlled Showers (superseded Fixtures by ASME A ) IAPMO PS with Atmospheric Vacuum Breakers 257

18 Table 14-1 UNIFORM PLUMBING CODE IAPMO PS Dental Vacuum Pumps Miscellaneous IAPMO PS Ballcock or Flushometer Valve Tailpiece Trap Primers and Trap Primer Receptors/Adapters DWV Components IAPMO PS 77-99[D] Electrohydraulic Water Closets (replaced Fixtures by ASME A ) IAPMO PS Dual Flush for Electrohydraulic and Gravity Water Closet 6 Liter (1.6 Gallon) Fixtures IAPMO PS Multiport Electronic Trap Primer DWV Components IAPMO PS 80-95e1 03b Grease Interceptors and Clarifiers DWV Components IAPMO PS Precast Concrete Seepage Pit Liners and Covers DWV Components IAPMO PS Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Fittings IAPMO PS 83-95[D] Epoxy-Coated Cast-Iron Sanitary Floor Sinks (replaced Fixtures by ASME A ) IAPMO PS 84-95[D] PVC Plastic Sanitary Floor Sinks (replaced by ASME A ) Fixtures IAPMO PS Tools for Mechanically Formed Tee Connections in Copper Tubing Piping IAPMO PS Rainwater Diverter Valve for Non-Roofed Area Slabs DWV Components IAPMO PS Diverter and Shutoff for Pool/Spas IAPMO PS Pre-Pressurized Potable Water Tanks Miscellaneous IAPMO PS Soaking and Hydrotherapy (Whirlpool) Bathtubs with Hydraulic Seatlift Fixtures IAPMO PS Elastomeric Test Caps/Cleanout Caps DWV Components IAPMO PS Plastic Stabilizers for Use with Plastic Closet Bends IAPMO PS Heat Exchangers Miscellaneous IAPMO PS Water Closet Seats with Spray Fixtures IAPMO PS a P-Trap, Supply Stop, and Riser Insulated Protector Miscellaneous IAPMO PS Drain, Waste, and Vent Hangers and Plastic Pipe Support Hooks Piping IAPMO PS Passive Direct Solar Water Heaters Miscellaneous IAPMO PS Mechanical Cast-Iron Closet Flanges IAPMO PS Prefabricated Fiberglass Church Baptistries Fixtures IAPMO PS Terrazzo Plumbing Fixtures Fixtures IAPMO PS Porous Filter Protector for Subdrain Weep Holes DWV Components IAPMO PS Suction Relief IAPMO PS Short Pattern Fixture Trap DWV Components 258

19 MANDATORY REFERENCED STANDARDS Table 14-1 IAPMO PS Water Heater Stands With or Without Pans Appliances IAPMO PS Pressure Relief Connection for Dispensing Equipment IAPMO PS Polyethylene Distribution Boxes DWV Components IAPMO PS Prefabricated, Tileable Shower Receptors Fixtures IAPMO PS Aramid-Reinforced Rubber Hose for Use in Non-Potable Water Radiant Heating and Snow Melting IAPMO PS Restaurant Fire Suppression Systems Appliances IAPMO PS PVC Cold Water Compression Fittings Fittings IAPMO PS PVC Cold Water Gripper Fittings Fittings IAPMO PS PVC Plastic for Cold Water Distribution Systems Outside a Building and CPVC Plastic for Hot and Cold Water Distribution Systems IAPMO PS e1 Hydraulically Powered Household Food Waster Grinders Appliances IAPMO PS e1 IAPMO PS Remote, Floor Box Industrial Water Supply, Air Supply, Drainage Demand or Automatic Activated Hot Water Pumping Systems Miscellaneous Miscellaneous IAPMO PS Hot Water Circulating Devices Which Do Not Use a Pump Miscellaneous IAMPO PS Press Type Copper and Copper Alloy Fittings for Installation on Copper Tubing Fittings IAPMO PS FOG (Fats, Oils, Greases) Disposal Systems DWV Components IAMPO PS Water Energized Sump Pump Miscellaneous IAS 1-91 U.S. Requirements for Indirect Water Heaters for Use with External Heat Source IAS LC 1-99 Fuel Gas Piping Systems Using Corrugated Stainless Steel CSA 6.26-M99 Tubing (CSST) Fuel Gas Fuel Gas ISO Guide LADWP General Requirements for Bodies Operating Product Certification Systems Ultra Low Flush Toilets - Requirements Certification MIL-F-1183 H-83[D] Fittings, Pipe, Cast Bronze, Silver-Brazing (discontinued) Piping, Copper Alloy MIL-F-18180C1 Flanges and Flanged Fittings, Pipe, Steel (150, 300, 400, 600, 900, 1500, and 2500 pounds) MIL-P-17552F Pumps, Centrifugal, Water, Horizontal, General Service; and Pumps, Centrifugal Water, Horizontal, Boiler-Feed; Electric Motor or Steam Driven Pumps MIL-P-21251E Pumping Units, Sewage, Duplex, Automatic, Wet Pit Type Pumps (Superseded by FS A-A-50555) MIL-P [D] Glass (standard cancelled per Department of Defense) Miscellaneous MIL-P Pump, Centrifugal: Electric-Motor-Driven, Shallow (A)-1976[D] Well (for Water) (discontinued) Pumps 259

20 Table 14-1 UNIFORM PLUMBING CODE MIL-P Submersible, Axial Flow, Electric-Motor- (1)-1983[D] Driven (discontinued) Pumps MIL-P-B-81[D] Sewage Pumps (discontinued) Pumps SSPMA-85 MIL-V [D] Pressurized Flushing Devices (discontinued) Fixtures MSS SP Standard Marking System for, Fittings, Flanges, and Unions Piping MSS SP Class 150 Corrosion-Resistant Gate-Globe, Angle, and Check with Flanged and Butt Weld Ends MSS SP Steel Pipeline Flanges MSS SP Pipe Hangers and Supports Materials, Design, and Manufacture Piping MSS SP Butterfly MSS SP Pipe Hangars and Supports - Selection and Application Piping MSS SP Cast-Iron Gate, Flanged and Threaded Ends MSS SP Cast-Iron Swing Check, Flanged and Threaded Ends MSS SP MSS SP Ball with Flanged or Butt-Welding Ends for General Service Brazing for Wrought and Cast Copper Alloy Solder Joint Pressure Fittings MSS SP Cast-Iron Plug, Flanged and Threaded Ends MSS SP Bronze Gate-Globe, Angle, and Check MSS SP Class 300 Steel Pipe Unions Socket-Welding and Threaded MSS SP-84 [D] MSS SP MSS SP MSS SP MSS SP MSS SP NFPA 13R Steel Socket-Welding Ends and Threaded Ends (discontinued) Pipe Hangars and Supports - Fabrication and Installation Practices Wrought Copper Solder Joint Pressure Fittings Cast Copper Alloy Flanges and Flanged Fittings, C.ass125, 150, and 300. Welded Fabricated Copper Solder Joint Pressure Fittings Non-Ferrous Threaded and Solder-Joint unions for use with copper water tube Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height Piping, Copper Alloy Miscellaneous NFPA 13D Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes Miscellaneous NFPA Installation of Oil-Burning Equipment Miscellaneous NFPA National Fuel Gas Code (same as ANSI Z223.1) Fuel Gas NFPA Storage and Handling of Liquefied Petroleum Gases Fuel Gas NFPA Boiler and Combustion Systems Hazards Code Appliances NFPA Health Care Facilities Piping 260

21 MANDATORY REFERENCED STANDARDS Table 14-1 NFPA 99C Gas and Vacuum Systems Piping NFPA Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances Miscellaneous NSF Commercial Spray-Type Dishwashing and Glasswashing Machines Appliances NSF e Automatic Ice Making Equipment Appliances NSF Plastic Piping Components and Related Materials NSF 18-96a Manual Food and Beverage Dispensing Equipment Appliances NSF Plumbing System Components for Manufactured Homes and Recreational Vehicles Miscellaneous NSF Chemical Feeders for Commercial Dishwashers Appliances NSF Residential Wastewater Treatment Systems DWV Components NSF Non-Liquid Saturated Treatment Systems DWV Components NSF e Drinking Water Treatment Units Aesthetic Effects Appliances NSF Addendum Residential Cation Exchange Water Softeners Appliances NSF Evaluation of Components and Devices Used in Wastewater Treatment Systems DWV Components NSF Drinking Water Treatment Units Health Effects Appliances NSF Addendum Reverse-Osmosis Drinking Water Treatment Systems Appliances NSF e Drinking Water System Components Health Effects Miscellaneous NSF Addendum Water Distillation Systems Appliances NSPI Public Swimming Pools Swimming Pools and Spas OG Operating Guidelines for Certifying Solar Collectors OG Operating Guidelines and Minimum Standards for Certifying Solar Water Systems PDI G Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data DWV Components PDI-WH Water Hammer Arresters Piping SAE J Automotive Tube Fittings Fittings SAE J Type F Clamps for Plumbing Applications SAMA LF6a Medical Care Facility Brassware Miscellaneous UL Steel Inside Tanks for Oil-Burner Fuel Miscellaneous UL UL Factory-Built Chimneys for Residential Type and Building Heating Appliances for Anhydrous Ammonia and LPG (Other than Safety Relief) Miscellaneous UL Safety Relief for Anhydrous Ammonia and LPG UL LPG Regulators UL Household Electric Storage Tank Water Heaters Appliances UL Commercial Electric Cooking Appliances 261

22 Table 14-1 UNIFORM PLUMBING CODE UL Compressed Gas Regulations UL Oil Burners Appliances UL Pumps for Oil-Burning Appliances Pumps UL Constant-Level Oil UL Draft Equipment Miscellaneous UL Drinking-Water Coolers Appliances UL Waste Disposers Appliances UL Gas Vents Miscellaneous UL Steel Auxiliary Tanks for Oil-Burner Fuel Miscellaneous UL Electrical Heating Appliances Appliances UL Ice Makers Appliances UL Pigtails and Flexible Hose Connectors for LP-Gas Fuel Gas UL Standard Test for Surface Burning Characteristics of Building Materials Miscellaneous UL Oil-Fired Boiler Assemblies Appliances UL Oil-Fired Storage Tank Water Heaters Appliances UL Household Dishwashers Appliances UL Motor-Operated Water Pumps Pumps UL Heating, Water Supply, and Power Boilers Electric Appliances UL Commercial Electric Dishwashers Appliances UL Factory Built, Medium Heat Appliance Chimneys Miscellaneous UL Electric Commercial Clothes Washing Equipment Appliances UL WQA S Electric Booster and Commercial Storage Tank Water Heaters Point-of-Use Low Pressure Reverse Osmosis Drinking Water Systems Appliances Appliances 3-GP-28 Fuel Oil, Canadian Government Specification Board Miscellaneous Notes: 1 Although this standard is referenced in Table 14-1, some of the pipe, tubing, fittings, valves, or fixtures included in the standard are not acceptable for use under the provisions of the Uniform Plumbing Code. 4 See Section for restriction. 5 Alloy C85200 for cleanout plugs. 6 Limited to domestic sewage. 7 Type II only. 9 ASSE 1066 is not intended to limit the maximum outlet temperature at point of use. 10 See Section for trenching, excavation, and backfilling requirements when installing building drains and sewers. Engineers may wish to consult ASTM D 2321 when preparing plans and specifications for sewer mains or specific projects. 262

23 MANDATORY REFERENCED STANDARDS Table 14-1 Index TABLE 14-1 INDEX Standards for Materials, Equipment,, and Connections Page numbers will be added before publishing Standard Number page Appliances AHAM DW AHAM DW-2PR AHAM FWD AHAM FWD-2-PR AHAM HLW-2 PR ANSI Z a... ANSI Z ANSI Z ANSI Z ANSI Z ANSI Z CSA 6.16-M ANSI Z CSA ARI ASME A (R98) (R02)... ASSE ASSE ASSE ASSE ASSE IAPMO PS IAPMO PS IAPMO PS e1... NFPA NSF NSF e... NSF 18-96a... NSF NSF Addendum NSF NSF NSF Addendum NSF Addendum UL UL UL UL UL UL UL UL UL UL UL UL UL WQA S Backflow Protection ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE ASSE Series AWWA C AWWA C CSA B CSA B CSA B CSA B CSA B CSA B CSA B CSA B CSA B CSA B CSA B

STANDARDS TASK GROUP REPORT

STANDARDS TASK GROUP REPORT STANDARDS TASK GROUP REPORT THE SCOPE OF THE STANDARDS TASK GROUP INCLUDES ADDING CROSS- REFERENCES TO TABLE 14-1 AND RECOMMEND WHERE SUCH REFERENCES ARE APPLICABLE TO THE REFERENCED STANDARDS AND TO UPDATE

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN CHAPTER 14 STANDARDS Note: Referenced sections will be updated before publishing. 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

2012 UPC STANDARDS TASK GROUP

2012 UPC STANDARDS TASK GROUP 2012 UPC STANDARDS TASK GROUP The scope of this task group is to review standard cross-references within the body of the 2009 Uniform Plumbing Code and Table 14-1. The objective is to update standards

More information

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS 19.1 REFERENCED STANDARDS Referenced Standards Chapter 19 Table 19.1 lists the standards that are referenced within the requirements of this Code. Table 19.1 shows the designation number of the standard,

More information

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 14-1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES November 21, 2017 Part I: Approved Listing Agencies Part II: Approved Testing

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES July 25, 2018 Part I: Approved Listing Agencies Part II: Approved Testing

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA 2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA I. Call to Order II. Chairman Comments III. Announcements IV. Self Introductions

More information

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications 1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications Product type Application Specification Appliances Bedpan

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION.............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

A. This Section includes the following domestic water piping specialties:

A. This Section includes the following domestic water piping specialties: SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur. First Revision No. 1-NFPA 501-2015 [ Section No. 5.3.1.3 ] 5.3.1.3 The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION................1 101.0 Title, Scope, and General...........1 101.1 Title............................1 101.2 Purpose.........................1 101.3 Plans Required...................1

More information

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments TABLE OF CONTENTS I Tentative Agenda II Tentative Order of Discussion III A2L Task Group Report IV Uniform Mechanical Code Change Public Comments 2017 Uniform Mechanical Code Technical Committee Meetings

More information

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018,

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018, STANDARDS Chapter 17, Part II CHAPTER 17 STANDARDS 1701.0 Scope Part I of this chapter covers standards that are hereby declared to be part of this code. Part II of this chapter lists standards which relate

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

Matrix of changes for the National Standard Plumbing Code July 2013

Matrix of changes for the National Standard Plumbing Code July 2013 Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

1 Exam Prep Plumbing State Contractors Practice Exam 2

1 Exam Prep Plumbing State Contractors Practice Exam 2 1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS)

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

Plumbing Technology/Plumber CIP Task Grid

Plumbing Technology/Plumber CIP Task Grid 1 Secondary Task List 100 DEMONSTRATE PERSONAL SAFETY IN THE TRAINING LABORATORY 101 Follow rules for fire safety. 102 Follow rules for housekeeping safety. 103 Follow shop rules. 104 Follow rules for

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Floor

More information

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR ELECTRICAL OR HIGH-DENSITY MAGNETIC ANTI-SCALE OR WATER CONDITIONING APPLIANCE IGC 91-2009 1. PURPOSE 1.1 The purpose

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type. PART 1 - GENERAL 1.1 Toilet rooms and utility rooms to have floor drains at lowest point. 1.2 Utilize Exposed Flushometers. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information

NFPA 54 UPDATE. Paul Cabot American Gas Association

NFPA 54 UPDATE. Paul Cabot American Gas Association NFPA 54 UPDATE Paul Cabot American Gas Association PRESENTATION TOPICS Summary Listing Schedule Revisions Definitions/General Piping Appliances and Appliance Installation Venting 2015 Edition Revision

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems CHAPTER 15 REFERENCED STANDARDS SECTION MC 1501 GENERAL 1501.1 General. This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the

More information

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY a. Only potable water shall be supplied to plumbing fixtures used for drinking, bathing, culinary use or the processing of food, medical or pharmaceutical

More information

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS). PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION BASIC MATERIALS AND METHODS

SECTION BASIC MATERIALS AND METHODS SECTION 15050 BASIC MATERIALS AND METHODS PART 1 1.1 SECTION INCLUDES A. General Conditions B. Supplementary Conditions C. Division 1 D. Mechanical basic requirements E. Electric Motors F. Pipe, Valve,

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point. PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS 22 00 70 (November 2011) Change 1-08/17 ----------------------------- Preparing Activity: USACE Superseding UFGS 22 00 70 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Mechanical Inspection Plumbing

Mechanical Inspection Plumbing 0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,

More information

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015 1.1 GOALS The goal of this section is to provide guidance in the design of Plumbing and Fire Protection systems to LAWA standards. The LAWA Plumbing Design Standards are a compilation of general design

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 22 63 13 GAS PIPING FOR LABORATORY AND HEALTHCARE FACILITIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

8501 E. Pleasant Valley Rd. Cleveland, OH 44131

8501 E. Pleasant Valley Rd. Cleveland, OH 44131 IAS Accreditation Number Company Name Address Contact Name TL-266 8501 E. Pleasant Valley Rd. Cleveland, OH 44131 Benjamin Barker Manager, Accreditations Telephone (416)747-4013 Effective Date of Scope

More information

SECTION ELECTRIC WATER HEATERS

SECTION ELECTRIC WATER HEATERS SECTION 22 36 01 ELECTRIC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers

More information

SPRINKLERS TABLE OF CONTENTS

SPRINKLERS TABLE OF CONTENTS SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

WATERSTONE ASSISTED LIVING AND MEMORY CARE

WATERSTONE ASSISTED LIVING AND MEMORY CARE DOMESTIC WATER PIPING SPECIALTIES BATON ROUGE, LOUISIANA SECTION 22 11 19 SECTION 22 11 19 - DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

REFRIGERANT PIPING SYSTEM

REFRIGERANT PIPING SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING SECTION 23 21 13 HYDRONIC PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following: 1. Hot-water

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what This practice exam will require you to have a calculator, pencil, scrap paper, a copy of the 2005 National Plumbing Code and will contain many similar questions as the current Plumbing Red Seal trade certification.

More information

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression

More information

SECTION PLUMBING

SECTION PLUMBING SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

REFRIGERANT PIPING

REFRIGERANT PIPING SECTION 232300 - REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

plumbing for greywater

plumbing for greywater plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of

More information

Planting Irrigation

Planting Irrigation University of New Hampshire University of New Hampshire Scholars' Repository Division 32 Exterior Improvements Chapter 5 Technical Construction and Renovation Standards 1-25-2013 328400 - Planting Irrigation

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS AG AVB PVB DCVA PA 1 Abattoir (slaughter house) 2 Air compressor oil cooler 3 Agricultural chemicals (sprayers 4 Animal watering 5 Apartment building (within the scope of Part 3 of the Ontario Building

More information

ESSAY: This will be a written paper of 6 essay questions. Candidates are to answer 5 questions in 2 hours for 60 marks.

ESSAY: This will be a written paper of 6 essay questions. Candidates are to answer 5 questions in 2 hours for 60 marks. 260 PLUMBING AND PIPE FITTING Examination Structure The examination for this syllabus will cover three major areas of groupings with 193 Building Engineering and 191 General Metal Work as trade-related

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Codes and Standards: A. Plumbing Code Compliance: Comply with applicable portions of National Standard Plumbing Code pertaining to selection and installation of Plumbing materials

More information

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure. SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.

More information

A. Section Joint Sealants: Seal fixtures to walls and floors.

A. Section Joint Sealants: Seal fixtures to walls and floors. SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2

More information

$0.98 $ KITCHEN SINK STRAINER, 3-1/2" x BATH TUB DRAIN, 1-15/16" x 2-3/4" x $ $1.89

$0.98 $ KITCHEN SINK STRAINER, 3-1/2 x BATH TUB DRAIN, 1-15/16 x 2-3/4 x $ $1.89 *s are Subject to Change without Notice.* WASHERS Rubber Beveled 5-1915 CLOSET, 3/8" O.D. TUBE $0.20 5-1916 CLOSET, 1/2" O.D. TUBE $0.20 5-1917 LAVATORY, 1/2" TALL x 3/8" O.D. $0.20 TUBE 5-1849 LAVATORY,

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES CSUEB Pioneer Heights Phase r 15410 Page 1 SECTION 15410 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub.

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub. CHAPTER 2 DEFINITIONS 201.0 General. For the purpose of this code, the following terms have the meanings indicated in this chapter. No attempt is made to define ordinary words which are used in accordance

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016 1.1 GOALS The goal of this section is to provide guidance in the design of Plumbing and Fire Protection systems to LAWA standards. The LAWA Plumbing Design Standards are a compilation of general design

More information

SECTION FUEL-FIRED DOMESTIC WATER HEATERS

SECTION FUEL-FIRED DOMESTIC WATER HEATERS SECTION 22 34 00 FUEL-FIRED DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not

More information