1 INSTALLATION MANUAL DOWNFLOW / HORIZONTAL COIL CABINET DOWNFLOW LOUVERED DOOR ASSEMBLY MODELS: 97-F SERIES LIST OF SECTIONS 1 General 1 3 Louvered Door Frame Assembly Installation 3 2 Safety 2 4 Coil Cabinet Installation 5 LIST OF FIGURES 1 Cooling Coil Cabinet Dimensions 1 4 A Coil Filters 4 2 Return Air Grille Frame Assembly 4 5 Coil Cabinet Door Mounting Bracket 5 3 Return Air Grille 4 6 Coil Cabinet Door Mounting Bracket Location 5 LIST OF TABLES 1 Coil Cabinet Models Nomenclature 3 2 Coil Cabinet and Return Frame Assembly Models 3 SECTION I: GENERAL The following list includes important facts and information regarding the louvered door frame assembly for your coil cabinet and its inclusions. 1. A/C coil cabinet designed to be attached to an electric furnace equipped with blower for A/C or Heat Pump operation. 2. A/C coil cabinets are available heights are shown in Table Frame and Grille assembly is available in an 18 inch height and a 24 inch height. 4. Frame and Grille assembly does not have an air filter. Air filters are placed on top of the cooling coil. Refer to Figure 4. NOTE: This furnace and its components listed on the A/C and Heat Pump equipment sticker were listed in combination as a system by ETL for the United States. Figure 1: Cooling Coil Cabinet Dimensions MORTEX PRODUCTS INC FORT WORTH, TX Page 1
2 SECTION II: SAFETY This is a safety alert symbol. When you see this symbol on labels or in manuals; be alert to the potential for personal injury. Understand and pay particular attention to the signal words DANGER, WARNING, or CAUTION. DANGER: indicates an imminently hazardous situation, which if not avoided, will result in death or serious injury. WARNING: indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. CAUTION: indicated a potentially hazardous situation, which if not avoided, may result in minor or moderate injury. It is also used to alert against unsafe practices and hazards involving property damage. FIRE OR ELECTRICAL HAZARD Failure to follow the safety warnings exactly could result in serious injury, death, or property damage. A fire or electrical hazard may result causing property damage, personal injury or loss of life. Improper installation may create a condition where the operation of the product could cause personal injury or property damage. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for assistance or for additional information consult a qualified contractor, installer, or service agency. This product must be installed in strict compliance with the installation instructions and any applicable local, state, and national codes including, but not limited to building, electrical, and mechanical codes. SAFETY REQUIREMENTS 1. Provide clearances for servicing ensuring service access is allowed for the coil compartment Failure to carefully read and follow all instructions in this manual can result in malfunction of the furnace, death, personal injury, and / or property damage. 3. Installing and servicing cooling equipment can be hazardous due to electrical components. 4. Only trained and qualified personnel should install repair or service heating / cooling equipment. Untrained service personnel can perform basic maintenance functions such as cleaning of exterior surfaces and replacing the air filters. Observe all precautions in the manuals and on the attached labels when working on this appliance. 5. These instructions cover minimum requirements and conform to existing national standards and safety codes. In some instances these instructions exceed certain local codes and ordinances, especially those who have not kept up with changing mobile home, modular home and HUD construction practices. These instructions are to be followed and are the minimum requirement for a safe installation. INSPECTION As soon as the coil cabinet is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier s freight bill. A separate request for inspection by the carrier s agent should be made in writing. Also check to be sure all accessories such as heater blend air kits are available. Installation of these accessories should be accomplished before the coil cabinet is set in place or the connecting of the wiring, electric heat, ducts or piping. CODES The furnace must be installed in accordance with the following codes. Standard for the Installation of Air Conditioning and Ventilating Systems (NFPA 90A) Standard for the Installation of Warm Air heating and Air Conditioning Systems (NFPA 90B) National Electrical Code (NFPA 70) Canadian Electrical Code, Part I (CSA C22.1) All local codes (State, City, and Township) NOTE: All applicable codes take precedence over any recommendation made in these instructions. MORTEX PRODUCTS INC FORT WORTH, TX Page 2
3 Series Door Type Top Cover Cabinet Type Cabinet Height 97-F S = Solid L = Louvered 21 = 23 1/4" 27 = 30 1/2" 39 = 41 1/4" B = Knocked Down F = Assembled O = Open S = Solid Table 1: Coil Cabinet Model Nomenclature Front Door of Cabinet Open Top 17 3/4" x 21 3/4" Maximum Air Flow CFM 1" Pleated Air Filter, In The Door 2" Pleated Air Filter, Top of Cabinet Height Depth Width Louvered N/A x /4" 25" 19 3/4" Solid x /4" 25" 19 3/4" Louvered x20 20x /4" 25" 19 3/4" Louvered N/A x /2" 25" 19 3/4" Solid x /2" 25" 19 3/4" Louvered x20 20x /2" 25" 19 3/4" Louvered N/A ea 20x /4" 25" 19 3/4" Solid x /4" 25" 19 3/4" Louvered N/A 1200 N/A N/A 18" N/A 19 3/4" Louvered N/A 1600 N/A N/A 24" N/A 19 3/4" Coil Sizes All Mortex 96 series coils will fit in cabinet series coils and 98 series coils sizes up to 98-8W7 All Mortex series coils will fit in cabinet Frame & Grills Non-Cabinet Table 2: Optional Coil Cabinet and Return Air Grille Models, CFM S and Air Filter Chart SECTION III: INSTALLING THE LOUVERED DOOR FRAME ASSEMBLY Alcove Installation This kit is approved for use in alcove installations with an approved air conditioning coil. The louvered door frame assemblies are available in 18 inch and 24 inch height. The furnace is 33 in height making the total furnace and filter frame assembly heights either 51 inches or 57 inches. To install the louvered door frame assembly to the furnace follow the steps below Prior to installing the furnace make sure the holes are cut into the floor for the refrigerant tubing, the electrical wiring are in place, the thermostat wiring and the condenser control wiring are in place. 1. Before installing the coil cabinet on the furnace, be sure you have enough clearance to install the furnace and the louvered door assembly. 2. Remove the louvered door frame assembly from the box. 3. Remove the front access panel (door) by removing the thumb screw that secures the door to the frame assembly. 4. Lay the frame assembly flanges against the furnace top cover and align the screw holes in the furnace top cover with the holes in the flanges of the frame assembly. Refer to Figure Install the screws through the holes provided in order to secure the frame assembly to the top of the furnace. 6. Slide the furnace on to the floor base and follow the instructions in the installation manual to properly install the furnace. 7. Follow the instructions to properly install the cooling coil. 8. Install the coil air filters as shown in figure 4 9. Place the ½ inch flange on the bottom of the door into the behind the flange provided on the frame assembly. 10. Push the door towards the frame assembly, then insert the thumb screw into the hole provided at the top of the door and tighten the screw until the door is securely fastened to the frame assembly. MORTEX PRODUCTS INC FORT WORTH, TX Page 3
4 NOTE: The installer must provide a strap that attaches to the top of the furnace and is secured to the alcove wood framing. Figure 2: Return Air Grille Frame Assembly Figure 4: A Coil Filters NOTE: Coil Filters are used with the 97-FG Frame and Grille assemblies only. SECTION IV: INSTALLING THE COIL CABINET Closet or Alcove Installation Figure 3: Return Air Grille This kit is approved for use in an alcove or closet installations with an approved air conditioning coil. The coil cabinets are available in 23 1/4, 30 1/2 and 40 1/4 height. The furnace is 33 in height making the total furnace and coil cabinet heights are 56, 63 and 73. To install the coil cabinet assembly to the furnace, follow the steps below Prior to installing the furnace make sure the holes are cut into the floor for the refrigerant tubing, the electrical wiring are in place, the thermostat wiring and the condenser control wiring are in place. 1. Before installing the coil cabinet on the furnace, be sure you have enough clearance to install the MORTEX PRODUCTS INC FORT WORTH, TX Page 4
5 furnace and the coil cabinet. If not, you may want to use a shorter coil cabinet or use a saw to enlarge the opening or the area where the furnace will be positioned. 2. Remove the parts from the box. Check for any damage before you start assembling the cabinet. 3. Place the rear panel against the left side panel and install the three (3) screws. 4. Place the rear panel against the right side panel and install the three (3) screws. 5. Place the coil cabinet top cover on the side and rear panels so the three flanges on the top cover overlap the side and rear panels. Install the nine (9) screws. 6. Turn the coil cabinet upside down and place the 1/2 inch seal strip along the bottom flanges of the coil cabinet back and side panels. Refer to Figure Set the coil cabinet on top of the furnace and secure to the furnace top cover with screws thru the three holes on the rear panel flange. 8. Place the coil cabinet door mounting bracket under the left and right side coil cabinet panel flanges. The door bracket must be placed between the coil cabinet side panel flanges and the furnace top cover. Refer to Figure Install the remaining screws thru the holes provided in the coil cabinet flanges to secure the coil cabinet to the furnace top cover. 10. Slide the furnace on to the floor base. Push the furnace back until the furnace casing is against the rear flange. 11. Slide the furnace on to the floor base and follow the instructions in the installation manual to properly install the furnace. 12. Follow the instructions to properly install the cooling coil. 13. Place the coil cabinet door into the two tabs provided on the coil cabinet door bracket. 14. Push the door towards the coil cabinet and insert the thumb screw into the hole provided at the top of the door and tighten the screw until the door is securely fastened to the coil cabinet. NOTE: The installer must provide a strap that attaches to the top of the furnace and is secured to the alcove or closet wood framing Figure 6: Coil Cabinet Door Bracket Location Subject to change without notice Copyright by Mortex Products Inc Supersedes: 61MH0012 MORTEX PRODUCTS INC FORT WORTH, TX Page 5
USERS INFORMATION MANUAL
USERS INFORMATION MANUAL DOWNFLOW For Installation In: SINGLE AND TWO STAGE 1. Manufactured (Mobile) Home 2. Recreational Vehicle ELECTRIC FURNACE 3. Modular Homes & Buildings 4. Residential Homes MODELS:
More informationUSERS INFORMATION MANUAL
MODULAR DX OR CHILLED WATER COOLING WITH ELECTRIC OR HOT WATER HEATING MODELS: US, UM SERIES USERS INFORMATION MANUAL For Installation In: 1. Modular Homes & Buildings 2. Residential Homes LIST OF SECTIONS
More informationINSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES
INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC ISO 9001 Certified Quality Management System SAFETY................................................
More informationINSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES
INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: ORIFICE METERING DEVICE - G*FD024S14 - G*FD060S24 FACTORY INSTALLED TXV - G*FD024S14T - G*FD060S24T
More informationINSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP
INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: ORIFICE METERING DEVICE - G*FD024S14 - G*FD060S24 FACTORY INSTALLED TXV - G*FD024S14T - G*FD060S24T
More informationInstallation Instructions
50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationPackaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump
Packaged Heat Pumps Owner s Guide to Operating and Maintaining Your Heat Pump NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces
More informationINSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214
INSTALLATION MANUAL FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: MC FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS MODELS: FC PARTIAL-CASED UPFLOW FOR COOLING/HEAT PUMP MODELS: PC ISO
More informationOwner s Information Manual
50EZ---A and 50VT ---A Comfort and Performance 13 and 14 SEER Single Packaged Heat Pump System With PuronR (R ---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Owner s Information
More informationInstallation Instructions
Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...
More informationInstallation Instructions
EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting
More informationFig. 1 - Unit PHD4 and WPH4
OWNER S MANUAL 14 SEER Single -Package Heat Pump System with R -410A Refrigerant Single Phase and Three Phase 2 to 5 Nominal Tons PHD4 Series F and WPH4 Series B Fig. 1 - Unit PHD4 and WPH4 A09034 NOTE
More informationINSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY
INSTALLATION MANUAL FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: MC FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS MODELS: FC PARTIAL-CASED UPFLOW FOR COOLING/HEAT PUMP MODELS: PC ISO
More informationInstallation Instructions
Installation Instructions B5BV Series Electric Furnaces For HUD approved installations in manufactured homes and modular homes These instructions are intended to assist qualified individuals experienced
More informationMODELS B1PA024, 030 AND 036
STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat
More informationINSTALLATION GUIDE. AAN & AEN Series - Manufactured Housing Electric Furnace. 1. Safety Instruction. 2. Inspection ! CAUTION CAUTION `!
INSTALLATION GUIDE AAN & AEN Series - Manufactured Housing Electric Furnace. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction with
More informationOwner s Information Manual
48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)
More informationInstallation Instructions
50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,
More informationInstallation Instructions Part No , Part No Part No
Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11
More informationFig. 1 - Unit PGD4, PGS4, WPG4
OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.
More informationINSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA
TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Models MB08B1500A2 MB12F1900A2 MB16J2200A2 MB20N2600A2 Contents 115 Volt General Information / Installation... 2 Installations... 3 Horizontal Installations... 3 Ductwork Connections...
More informationInstallation Instructions
HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.
More informationINTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can
More informationInstallation Instructions
Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Electric Heat Sections Used with Blower Coil Units ELECTRIC HEAT SECTIONS 505,084M (0655012-30) 05/15 Supersedes 09/11 Litho U.S.A. NOTICE TO INSTALLER IT IS HIGHLY RECOMMENDED
More informationInstallation Instructions
Toshiba Carrier RAV Series Ductless Wind Baffle Fabrication and Installation RAV-SP180AT2-UL RAV-SP240AT2-UL RAV-SP300AT2-UL RAV-SP360AT2-UL RAV-SP420AT2-UL Installation Instructions SAFETY CONSIDERATIONS
More informationInstallation Instructions
8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting
More informationPackaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.
Packaged Air Conditioning Units Owner s Guide to Operating and Maintaining Your Air Conditioner ELECTRICAL SHOCK HAZARD. Failure to follow this warning could result in personal injury, Disconnect power
More informationInstallation Instructions
CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting
More informationPL Series Premier Indoor Plenum Coils
IM-PLC-0667392-04 April 2016 PL Series Premier Indoor Plenum Coils Installation Instructions GENERAL ADP evaporator coils are designed for use with condensing units or heat pump units. These instructions
More informationINSTALLATION MANUAL HIGH EFFICIENCY SEALED COMBUSTION DRUM HEAT EXCHANGER SERIES
INSTALLATION MANUAL HIGH EFFICIENCY SEALED COMBUSTION DRUM HEAT EXCHANGER SERIES MODEL: DFAA/DFAH (Oil and Gas Conversion Burner/ Single Stage Downflow Only) 66-84 MBH INPUT (19.34-24.62 KW) INPUT EFFICIENCY
More informationINSTALLATION MANUAL MANUFACTURED HOUSING OR MODULAR HOME GAS FURNACE
INSTALLATION MANUAL MANUFACTURED HOUSING OR MODULAR HOME GAS FURNACE MODELS: MG9S*MP - 33 Models Shipped in Downflow Configuration (95.5% AFUE Single Stage Multi-position) EFFICIENCY RATING CERTIFIED ISO
More informationInstallation Instructions
Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationINSTALLATION INSTRUCTIONS TABLE OF CONTENTS
KSAIF KSAIF0501AAA & KSAIF0601AAA Wi-Fi Interface Kit for Ductless Systems INSTALLATION INSTRUCTIONS NOTE: Read and become familiar with these instructions before beginning installation. TABLE OF CONTENTS
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More informationOIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE
58CLA OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME TO A NEW GENERATION
More informationInstallation Instructions
40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS
More informationINSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES
INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on
More informationResidential Duct Mount Builder s Box Media Air Cleaner
INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Residential Duct Mount Builder s Box Media Air Cleaner Part Numbers: P102-BB14A, P102-BB20 IMPORTANT: Read entire instructions before installing the
More informationInstallation Instructions
Heat Exchanger Cell Replacement Kit Cancels: IIK 373-35-12 IIK 373L-35-14 12-15-93 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation.
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,
More informationOwner's Guide to Operating and Maintaining Your Gas/Electric Unit
Packaged Gas Heat/Electric Cooling Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK. FIRE OR EXPLOSION Failure to follow this warning could result in personal injury,
More informationINSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL
INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................
More informationInstallation Instructions
HC2 HC3 HOT WATER COILS MULTIPOISE Installation Instructions NOTE: Read the entire installation instructions before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More informationInstallation Instructions
40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the
More informationInstallation Instructions
40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...
More informationThis document was created with FrameMaker 4.0.4
This document was created with FrameMaker.0. WELCOME TO TODAY S GENERATION OF COMFORT Congratulations! Your new, higher efficiency gas furnace is a sound investment which will reward you and your family
More informationInstallation Instructions
Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper
More informationMANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION Fan Column v200 Issue Date: 01/18/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General Safety Information...1 Safety Notices...1 Unit Description...2
More informationInstallation Instructions
CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationKSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual
KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems Owner's Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 3 WIRED CONTROLLER FEATURES AND FUNCTIONS... 5 WIRED CONTROLLER
More informationRE9X Series Downflow, Upflow Electric Furnaces
TECHNICAL SPECIFICATIONS RE9X Series Downflow, Upflow Electric Furnaces The RE9X Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low
More informationInstallation Instruction
KGADC0101BVC INTERNAL VENT KIT Installation Instruction NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,
More informationNOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
c_::_':_-_:_ r'" _" "_1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may Iresult causing property damage, personal injury or [loss of life. m m m Do not store
More informationInstallation Instructions
Installation Instructions For Cased Coils Upflow-Downflow Heating-Cooling CK5A CK5B SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation NOTE: Read the entire instruction
More informationInstallation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365
Distinctive Electric Cooktop Models DECT304, DECT365 Installation Instructions 105643 Rev. A Françis : voir page 11 Español: consulte la página 21 Table of Contents Page Special Warnings... Product Dimensions
More informationA. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.
SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationInstallation Instructions
40MBD Ducted Style Ductless System Sizes 09 to 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2
More informationInstallation in Standard & Variable Speed Indoor Air Handlers IMPORTANT
H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals
More informationInstallation Instructions
CNPHP Cased N s Horizontal Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION...
More informationIndicates a hazardous situation which, if not avoided, will result in death or serious injury.
Installation Instructions If you have any questions, call 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca This is the safety
More informationOutdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions
Installation Instructions Models: RTG 199HE / RTG 199ME Outdoor kit Warning: This kit must be installed by a qualified installer in accordance with these instructions and all applicable codes and requirements
More informationInstallation Instructions
Evaporator Coil A Coil --- Cased Multipoise NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationINSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF
INSTALLATION MANUAL FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS MODELS: CF FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CM ISO 9001 Certified Quality Management System GENERAL..............................................
More informationInstallation Instructions
EZXCAB Sizes 016 and 020 High Efficiency Air Filtration System Installation Instructions JAN High Efficiency Air Filtration System Fig. 1 - EZXCAB C04001 NOTE: Read the entire instruction manual before
More informationInstallation Instructions
Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationInstallation. Built-in Full Height Wine Cellar VCWB301
Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information
More informationHOME OWNER S INFORMATION Induced Combustion Gas Furnace
HOME OWNER S INFORMATION Induced Combustion Gas Furnace NOTE TO INSTALLER: This manual must be left with the equipment user. USER: Please read all instructions in the manual and retain all manuals for
More informationInstallation Instructions
CAELHEAT001A00 - CAELHEAT039A00 AAHC05AHAA - AAHC70ESAA PACKAGED AIR---HANDLING UNITS ELECTRIC HEAT ACCESSORY 6 to 30 TONS (21 to 105 kw) 50/60 Hz Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS...
More informationOwner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
Induced Combustion Gas Furnace Owner's Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.
More informationInstallation Instructions
Heat Exchanger Cell Replacement Kit Cancels: IIK 373L-35-14 IIK 373L-35-17 3-97 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation.
More informationInstallation Instructions
Primary Cell Inlet Panel Kit Installation Instructions Part No. 320720-751, -753, -754, -755, -756, -757,-758, and -760 NOTE: Read the entire instruction manual before starting the installation. This symbol
More informationInstallation Instructions
Installation Instructions For Cased and Uncased Coils Upflow-Downflow Heating-Cooling CK5A, CK5B Cased CJ5A Uncased SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation
More informationTABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.
Installation NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION... 2 Inspect Equipment... 2 Select
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND
More informationRV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER
RV Products Division INSTALLATION INSTRUCTIONS FOR 46413 SERIES PACKAGE AIR CONDITIONER 1. WARNINGS IMPORTANT NOTICE These instructions are for the use of qualified individuals specially trained and experienced
More informationYour safety and the safety of others are very important.
VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3
More informationInstallation Instruction
Installation Instruction Upflow Downflow Heating Cooling CC5A Uncased Coil CD5A Cased Coil SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Installation of CD5A Cased Coil A96244 NOTE:
More informationAM0**GNVQCH INSTALLATION MANUAL
AM0**GNVQCH INSTALLATION MANUAL Multi-position, Upflow, and Horizontal, DX Air Handling Unit Compatible with SAMSUNG DVM S VRF Systems AHU MODELS: AM0GNVQCH AM08GNVQCH AM0GNVQCH AM00GNVQCH AM06GNVQCH AM08GNVQCH
More informationInstallation Electric Dryers Instructions 01
Installation Electric Dryers Instructions 01 Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com This is the safety alert symbol. This symbol alerts you to potential
More informationInstallation Instructions
CNPHP Cased N Coils Horizontal Heating --- Cooling NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationELECTRONIC AIR CLEANER SAFETY AND INSTALLATION MANUAL MODEL 5000 TABLE OF CONTENTS
ELECTRONIC AIR CLEANER SAFETY AND INSTALLATION MANUAL MODEL 5000 TABLE OF CONTENTS Safety Instructions...2 Specifications...2 Components...3 Installation...4 Operating Instructions...6 Trouble Shooting
More informationINSTALLATION MANUAL TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-B-0806
INSTALLATION MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: PT9 / FC9T / FL9T (Two Stage Downflow/Horizontal) 60-120 MBH INPUT (17.62-35.17 KW) INPUT EFFICIENCY RATING CERTIFIED ISO 9001
More informationINSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP
INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................
More informationInstallation Instructions
CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11
More informationUser Manual Box Exhaust Fan Series (Belt Drive)
User Manual Box Exhaust Fan Series (Belt Drive) 36" Box Exhaust Fan with Three Wing Blade Box with Aluminum Shutter 54" Box with Cone 800-779-3267 sales@schaeferfan.com www.schaeferfan.com 2013 Schaefer
More informationViking Installation Guide
Viking Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com
More informationP.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces
P.O. Box 799900, Dallas, TX 75379-9900 USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals,
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD
TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS C7BA Series Split System Indoor Cased Coils IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able
More informationNOTE TO INSTALLER: This manual must be left with the equipment user. Model 480BAV Upflow and 481BAV Downflow/Horizontal
NOTE TO INSTALLER: This manual must be left with the equipment user. Model 0BAV Upflow and BAV Downflow/Horizontal USER S INORMATION MANUAL OR THE OPERATION AND MAINTENANCE O YOUR NEW GAS-IRED URNACE WARNING:
More informationR-410A AFFINITY SERIES DEX DEY Ton
R-410A AFFINITY SERIES 024-048 DEY060 2-5 Ton ISO 9001 Certified Quality Management System General.......................................... 1 Installation........................................ 3 Limitations......................................
More information