Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Size: px
Start display at page:

Download "Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S"

Transcription

1 Baset13 Air Conditioner with Puronr Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 24ABA has been designed utilizing Carrier s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth s ozone layer. As an Energy Starr Partner, Carrier Corporation has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S S S Sound S Comfort S SEER/ EER Microtube Technologyt refrigeration system Indoor air quality accessories available Sound level as low as 76 dba supports Thermidistatt or standard thermostat controls Reliability S S S S S S Durability Puronr refrigerant - environmentally sound, won t deplete the ozone layer and low lifetime servce cost. Scroll compressor Internal pressure relief valve Internal thermal overload Filter drier Balanced refrigeration system for maximum reliability WeatherArmort protection package: S Solid, durable sheet metal construction S Dense wire coil guard S Baked -on powder paint Applications S Long -line - up to 250 feet total equivalent length, up to 200 feet condenser above evaporator, or up to 80 ft. evaporator above condenser (See Longline Guide for more information.) S Low ambient (down to -20_F/-28.9_C)) with accessory kit Warranty S 5 year limited compressor warranty S 5 year limited parts warranty

2 MODEL NUMBER NOMENCLATURE N N A A A/N N N N A/N A/N A/N N N 2 4 A B A A Product Series Product Family Tier Major Series SEER Cooling Capacity 24=AC A=RES AC B=Base A=Puron 3=13 SEER A=Standard Variations Open Open Voltage Series 0=Not Defined 0=Not Defined 3=208/ = Original Series ISO 9001:2000 the environmentally sound refrigerant REGISTERED This product has been designed and manufactured to meet Energy Star criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES Feature Puron Refrigerant X X X X X X X 13 SEER X X X X X X X Scroll Compressor X X X X X X X DenseWireCoilGuard X X X X X X X FieldInstalledFilterDrier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X 2

3 PHYSICAL DATA UNIT SIZE---VOLTAGE, SERIES Operating Weight (lb) Shipping Weight (lb) Compressor Type REFRIGERANT Control Scroll Puron (R---410A) TXV (Puron Hard Shutoff) Charge (lb) COND FAN Air Discharge Propeller Type, Direct Drive Vertical Air Qty (CFM) Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/4 Motor RPM COND COIL Face Area (Sq ft) Fins per In Rows Circuits VALVECONNECT.(In.ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Vapor ( Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/ /8 Liquid ( Ft Tube Length) 3/8 * For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON 1-STAGE AIR CONDITIONER APPLICATIONS LONG LINE APPLICATION: An application is considered Long line when the total equivalent tubing length exceeds 80 ft or when there is more than 20 Ft vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250Ft. The maximum vertical separation is 200 Ft when outdoor Unit Nominal Size (Btuh) 18, Stage Puron AC 24, Stage Puron AC 30, Stage Puron AC 36, Stage Puron AC 42, Stage Puron AC 48, Stage Puron AC 60, Stage Puron AC Acceptable Vapor Line Diameters (In. O.D.) Standard Application unit is above indoor unit, and up to 80 Ft when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Long -Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss. Cooling Capacity Loss (%) Total Equivalent Line Length (ft..) Long Line Application Requires Accessories / / / / / / / / / / / / / / / / / / / / Standard Length = 80 Ft or less total equivalvent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines 3

4 ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. DESCRIPTION TSTATCCPRH01--- B Thermidistat Control --- Programmable / Non--- Programmable Thermostat with Humidity control TSTATCCPAC01--- B Thermostat --- Auto Changeover, Day Programmable, _F/_C, Stage Heat, Stage Cool TSTATCCNAC01--- C Thermostat --- Auto Changeover, Non --- Programmable, _F/_C, Stage Heat, Stage Cool TSTATCCBAC01--- B Builder s Thermostat --- Manual Changeover, Non--- Programmable, _F/_C, Stage Heat, Stage Cool TSTATCCSEN01---B Outdoor Air Temperature Sensor TSTATXXBBP01 Backplate for Builder s Thermostat TSTATXXNBP01 Backplate for Non--- Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wires) Pack ACCESSORIES Size --- Voltage & Series KIT NUMBER DESCRIPTION KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X KAATD0101TDR TIME DELAY RELAY X X X X X X X KAAWS0101AAA WINTER START X X X X X X X KSALA LOW AMBIENT PSW X X X X X X X KSALA0601AAA{ MOTORMASTER 230V X X X X X X X HC32GE234 MOTOR FAN BALL BEARING X HC34GE239 MOTOR FAN BALL BEARING X X HC40GE226 MOTOR FAN BALL BEARING X X HC38GE219 MOTOR FAN BALL BEARING X HC40GE228 MOTOR FAN BALL BEARING X KSAHS1701AAA HARD START (CAP / RELAY) X X X X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X KAACS0201PTC START ASSIST PTC X X X X X X X KAACH1201AAA CRANKCASE HTR X X X KAACH1401AAA CRANKCASE HTR X X X X KSATX0201PUR TXV PURON HSO X X X KSATX0301PUR TXV PURON HSO X X KSATX0401PUR TXV PURON HSO X KSATX0501PUR TXV PURON HSO X KSASH0601COP SOUND HOOD X X X X X X KSASH2101COP SOUND HOOD X KAALP0301PUR LOW PRESSURE SWITCH X X X X X X X KAAHI0401PUR HIGH PRESSURE SWITCH X X X X X X X { Required accessories include ball bearing fan motor, compressor start assist (CAP / Relay), crankcase heater, evaporator freeze stat, hard shut---off TXV. 4

5 ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW---AMBIENT COOLING APPLICATIONS (Below 55 F/12.8_C) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 Ft.) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles) Accumulator No No No Ball Bearing Fan Motor Yes{ No No Compressor Start Assist Capacitor and Relay Yes{ Yes No Crankcase Heater Yes{ Yes No Evaporator Freeze Thermostat Yes{ No No Hard Shut --- Off TXV Yes{ Yes Yes Liquid Line Solenoid Valve No See Long Line Application Guideline No Motor Master Control or Low --- ambient Pressure Switch Yes{ No No Support Feet Recommended No Recommended * For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differntial, refer to Residential Split--- Longline Application Guideline. { Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control. Accessory Description and Usage (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Required on all units when MotorMasterr 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a hard boost to compressor motor at each start up. Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist PTC Type Solid state electrical device which gives a soft boost to the compressor at each start -up. Suggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5 -minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze -up conditions. Required when low ambient kit has been added. 7. Low -Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low -ambient temperatures down to 0_F when properly installed. A Low -Ambient Pressure Switch or MotorMasterr Low -Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 8. MotorMasterr Low -Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± _C). A MotorMasterr Low Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 9. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Suggested for all Carrier thermostats listed in this publication. 5

6 Accessory Description and Usage (Listed Alphabetically) (Continued) 10. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Suggested when unit is installed closer than 15 ft to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft apart. 11. Support Feet Four stick -on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 12. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 13. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 14. Winter Start Control This control is designed to alleviate nuisance opening of the low -pressure switch by bypassing it for the first 3 minutes of operation. 6

7 ELECTRICAL DATA UNIT SIZE --- VOLTAGE, SERIES V/PH OPER VOLTS* COMPR FAN MCA MIN WIRE SIZE{ MIN WIRE SIZE{ MAX LENGTH (FT)} MAX LENGTH (FT)} MAX MIN LRA RLA FLA 60 C 75 C 60 C 75 C /230/ MAX FUSE** or CKT BRK AMPS * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30_C (86_F), consult table of the NEC (ANSI/NFPA 70). The ampacity of non---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60_C (140_F) conditions, per the NEC (ANSI/NFPA 70) Article If other than uncoated (no---plated), 60 or 75_C (140 or 167_F) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). } Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time --- Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA ---RatedLoadAmps NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. SOUND POWER UNIT SIZE --- VOLTAGE, SERIES STANDARD RATING (dba) TYPICAL OCTAVE BAND SPECTRUM (db, without tone adjustment) SOUND POWER WITH SOUND SHIELD UNIT SIZE --- VOLTAGE, SERIES STANDARD RATING (dba) TYPICAL OCTAVE BAND SPECTRUM (db, without tone adjustment) CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE--- VOLTAGE & SERIES REQUIRED SUBCOOLING _F (_C) (4.4) (7.2) (8.9) (8.9) (5.6) (9.4) (6.1) 7

8 DIMENSIONS 8

9 COMBINATION RATINGS Unit Size --- Voltage, Series Factory SEER Total Cap. Indoor Supplied BTUH Standard EER Furnace Enhancement TDR Rating *CAP**1814A** 17,500 TXV CAP**1814A** 17,200 TDR&TXV CV(A,X) CAP**2414A** 17,500 TDR&TXV CV(A,X) CAP**2414A** 17,700 TXV CAP**2417A** 17,600 TDR&TXV CV(A,X) CAP**2417A** 17,500 TDR&TXV MVB CAP**2417A** 17,700 TXV CNPF*2418A** 17,700 TXV CNPH*2417A** 17,500 TDR&TXV CV(A,X) CNPH*2417A** 17,600 TDR&TXV CV(A,X) CNPH*2417A** 17,500 TDR&TXV MVB CNPH*2417A** 17,500 TDR&TXV MVB CNPH*2417A** 17,600 TDR&TXV MVB CNPH*2417A** 17,700 TXV CNPV*1814A** 17,200 TDR&TXV CV(A,X) CNPV*1814A** 17,500 TXV CNPV*2414A** 17,500 TDR&TXV CV(A,X) CNPV*2414A** 17,700 TXV CNPV*2417A** 17,600 TDR&TXV CV(A,X) CNPV*2417A** 17,500 TDR&TXV MVB CNPV*2417A** 17,700 TXV CSPH*2412A** 17,500 TDR&TXV CV(A,X) CSPH*2412A** 17,600 TDR&TXV CV(A,X) CSPH*2412A** 17,500 TDR&TXV MVB CSPH*2412A** 17,500 TDR&TXV MVB CSPH*2412A** 17,600 TDR&TXV MVB CSPH*2412A** 17,700 TXV FF1ENP018 17,400 TDR&TXV FF1ENP024 17,600 TDR&TXV FV4BNF002 17,800 TDR&TXV FX4CNF018 17,600 TDR&TXV FX4CNF024 17,900 TDR&TXV FY4ANF018 17,400 TDR&TXV FY4ANF024 17,500 TDR&TXV *CAP**2414A** 23,000 TXV CAP**2414A** 22,600 TDR&TXV CV(A,X) CAP**2417A** 22,600 TDR&TXV CV(A,X) CAP**2417A** 22,600 TDR&TXV MVB CAP**2417A** 22,800 TXV CAP**3014A** 22,800 TDR&TXV CV(A,X) CAP**3014A** 23,000 TXV CAP**3017A** 22,800 TDR&TXV CV(A,X) CAP**3017A** 22,800 TDR&TXV MVB CAP**3017A** 23,000 TXV CNPF*2418A** 22,800 TXV See notes on pg. 13 CNPH*2417A** 22,600 TDR&TXV CV(A,X) CNPH*2417A** 22,600 TDR&TXV MVB CNPH*2417A** 22,800 TXV

10 COMBINATION RATINGS (CONT.) Unit Size --- Voltage, Series Indoor Total Cap. BTUH Factory Supplied Enhancement SEER Standard Rating TDR EER Furnace CNPH*3017A** 22,800 TDR&TXV CV(A,X) CNPH*3017A** 22,800 TDR&TXV MVB CNPH*3017A** 23,000 TXV CNPV*2414A** 22,600 TDR&TXV CV(A,X) CNPV*2414A** 22,800 TXV CNPV*2417A** 22,600 TDR&TXV CV(A,X) CNPV*2417A** 22,600 TDR&TXV MVB CNPV*2417A** 22,800 TXV CNPV*3014A** 22,800 TDR&TXV CV(A,X) CNPV*3014A** 23,000 TXV CNPV*3017A** 22,800 TDR&TXV CV(A,X) CNPV*3017A** 22,800 TDR&TXV MVB CNPV*3017A** 23,000 TXV CSPH*2412A** 22,800 TDR&TXV CV(A,X) CSPH*2412A** 22,800 TDR&TXV CV(A,X) CSPH*2412A** 22,800 TDR&TXV CV(A,X) CSPH*2412A** 22,800 TDR&TXV CV(A,X) CSPH*2412A** 22,600 TDR&TXV MVB CSPH*2412A** 22,800 TDR&TXV MVB CSPH*2412A** 23,000 TXV CSPH*3012A** 22,800 TDR&TXV CV(A,X) CSPH*3012A** 22,800 TDR&TXV CV(A,X) CSPH*3012A** 22,800 TDR&TXV CV(A,X) CSPH*3012A** 22,800 TDR&TXV CV(A,X) CSPH*3012A** 22,800 TDR&TXV CV(A,X) CSPH*3012A** 22,800 TDR&TXV MVB CSPH*3012A** 22,800 TDR&TXV MVB CSPH*3012A** 22,800 TDR&TXV MVB CSPH*3012A** 22,800 TDR&TXV MVB CSPH*3012A** 22,800 TDR&TXV MVB CSPH*3012A** 22,800 TDR&TXV MVB CSPH*3012A** 23,000 TXV F(A,B)4BN(F,C)024 22,400 TDR F(A,B)4BN(F,C)030 22,600 TDR FF1DNA024 22,200 TDR FF1DNA030 22,600 TDR FF1ENP024 22,600 TDR&TXV FF1ENP030 22,600 TDR&TXV FV4BNF002 23,000 TDR&TXV FV4BNF003 23,000 TDR&TXV FX4BNF030 22,800 TDR&TXV FX4CNF024 23,000 TDR&TXV FX4CNF030 23,200 TDR&TXV FY4ANF024 22,600 TDR&TXV FY4ANF030 22,800 TDR&TXV *CAP**3014A** 28,000 TXV CAP**3014A** 27,600 TDR&TXV CV(A,X) CAP**3017A** 28,000 TXV CAP**3017A** 27,600 TDR&TXV MVB CAP**3017A** 27,600 TDR&TXV CV(A,X) CAP**3614A** 27,000 TXV CAP**3614A** 26,600 TDR&TXV CV(A,X) See notes on pg

11 COMBINATION RATINGS (CONT.) Unit Size --- Voltage, Series Indoor Factory SEER Total Cap. Supplied BTUH Standard Enhancement TDR Rating EER Furnace CAP**3617A** 28,000 TXV CAP**3617A** 27,600 TDR&TXV MVB CAP**3617A** 27,800 TDR&TXV CV(A,X) CAP**3621A** 28,000 TXV CAP**3621A** 27,800 TDR&TXV MVB CAP**3621A** 27,800 TDR&TXV CV(A,X) CNPV*3014A** 28,000 TXV CNPV*3014A** 27,600 TDR&TXV CV(A,X) CNPV*3017A** 28,000 TXV CNPV*3017A** 27,600 TDR&TXV MVB CNPV*3017A** 27,600 TDR&TXV CV(A,X) CNPV*3617A** 28,000 TXV CNPV*3617A** 27,600 TDR&TXV MVB CNPV*3617A** 27,600 TDR&TXV CV(A,X) CNPV*3621A** 28,000 TXV CNPV*3621A** 27,600 TDR&TXV MVB CNPV*3621A** 27,800 TDR&TXV CV(A,X) CNPH*3017A** 28,000 TXV CNPH*3017A** 27,600 TDR&TXV MVB CNPH*3017A** 27,600 TDR&TXV CV(A,X) CNPH*3617A** 28,000 TXV CNPH*3617A** 27,600 TDR&TXV MVB CNPH*3617A** 27,600 TDR&TXV CV(A,X) CNPF*3618A** 28,000 TXV CSPH*3012A** 28,000 TXV CSPH*3012A** 27,600 TDR&TXV MVB CSPH*3012A** 27,600 TDR&TXV CV(A,X) CSPH*3612A** 28,000 TXV CSPH*3612A** 27,600 TDR&TXV MVB CSPH*3612A** 27,600 TDR&TXV CV(A,X) FY4ANF030 27,600 TDR&TXV FY4ANF036 27,800 TDR&TXV FX4CNF030 28,000 TDR&TXV FX4CN(B,F)036 28,200 TDR&TXV FF1ENP030 27,400 TDR&TXV FF1ENP036 28,000 TDR&TXV FV4BNF002 27,800 TDR&TXV FV4BNF003 28,000 TDR&TXV FV4BNF005 28,800 TDR&TXV *CAP**3617A** 34,000 TXV CAP**3614A** 32,600 TDR&TXV CV(A,X) CAP**3614A** 33,000 TXV CAP**3617A** 33,600 TDR&TXV CV(A,X) CAP**3617A** 33,600 TDR&TXV MVB CAP**3621A** 33,800 TDR&TXV CV(A,X) CAP**3621A** 33,600 TDR&TXV MVB CAP**3621A** 34,000 TXV See notes on pg. 13 CAP**4221A** 34,000 TDR&TXV CV(A,X) CAP**4221A** 33,800 TDR&TXV MVB

12 COMBINATION RATINGS (CONT.) Unit Size --- Voltage, Series Factory SEER Total Cap. Indoor Supplied BTUH Standard EER Enhancement TDR Rating CAP**4221A** 34,000 TXV Furnace CAP**4224A** 34,000 TDR&TXV CV(A,X) CAP**4224A** 33,800 TDR&TXV MVB CAP**4224A** 34,000 TXV CNPF*3618A** 34,000 TXV CNPH*3617A** 33,400 TDR&TXV CV(A,X) CNPH*3617A** 33,400 TDR&TXV MVB CNPH*3617A** 34,000 TXV CNPH*4221A** 33,800 TDR&TXV CV(A,X) CNPH*4221A** 33,800 TDR&TXV MVB CNPH*4221A** 33,800 TDR&TXV MVB CNPH*4221A** 34,000 TXV CNPV*3617A** 33,600 TDR&TXV CV(A,X) CNPV*3617A** 33,400 TDR&TXV MVB CNPV*3617A** 34,000 TXV CNPV*3621A** 33,800 TDR&TXV CV(A,X) CNPV*3621A** 33,600 TDR&TXV MVB CNPV*3621A** 34,000 TXV CNPV*4221A** 34,000 TDR&TXV CV(A,X) CNPV*4221A** 33,800 TDR&TXV MVB CNPV*4221A** 34,000 TXV CSPH*3612A** 33,600 TDR&TXV CV(A,X) CSPH*3612A** 33,600 TDR&TXV MVB CSPH*3612A** 34,000 TXV CSPH*4212A** 34,000 TDR&TXV CV(A,X) CSPH*4212A** 33,800 TDR&TXV MVB CSPH*4212A** 34,000 TXV FF1ENP036 33,800 TDR&TXV FV4BNB006 35,400 TDR&TXV FV4BNF002 33,600 TDR&TXV FV4BNF003 34,000 TDR&TXV FV4BNF005 35,000 TDR&TXV FX4CN(B,F)036 34,400 TDR&TXV FX4CN(B,F)042 34,800 TDR&TXV FY4ANF036 33,800 TDR&TXV FY4ANF042 34,400 TDR&TXV *CAP**4221A** 41,000 TXV CAP**4221A** 40,500 TDR&TXV CV(A,X) CAP**4221A** 40,000 TDR&TXV MVB CAP**4224A** 40,500 TDR&TXV CV(A,X) CAP**4224A** 40,000 TDR&TXV MVB CAP**4224A** 41,000 TXV CAP**4817A** 40,000 TDR&TXV CV(A,X) CAP**4817A** 40,000 TDR&TXV MVB CAP**4817A** 40,500 TXV CAP**4821A** 41,000 TDR&TXV CV(A,X) CAP**4821A** 40,500 TDR&TXV MVB CAP**4821A** 41,500 TXV See notes on pg. 13 CAP**4824A** 41,000 TDR&TXV CV(A,X)

13 COMBINATION RATINGS (CONT.) Unit Size --- Voltage, Series Factory SEER Total Cap. Indoor Supplied BTUH Standard EER Furnace Enhancement TDR Rating CAP**4824A** 41,000 TDR&TXV MVB CAP**4824A** 41,500 TXV CNPF*4818A** 41,500 TXV CNPH*4221A** 40,500 TDR&TXV CV(A,X) CNPH*4221A** 40,000 TDR&TXV MVB CNPH*4221A** 41,000 TXV CNPH*4821A** 41,000 TDR&TXV CV(A,X) CNPH*4821A** 40,500 TDR&TXV MVB CNPH*4821A** 41,500 TXV CNPV*4221A** 40,500 TDR&TXV CV(A,X) CNPV*4221A** 40,000 TDR&TXV MVB CNPV*4221A** 41,000 TXV CNPV*4821A** 41,000 TDR&TXV CV(A,X) CNPV*4821A** 40,500 TDR&TXV MVB CNPV*4821A** 41,500 TXV CNPV*4824A** 41,000 TDR&TXV CV(A,X) CNPV*4824A** 41,000 TDR&TXV MVB CNPV*4824A** 41,500 TXV CSPH*4212A** 40,500 TDR&TXV CV(A,X) CSPH*4212A** 40,000 TDR&TXV MVB CSPH*4212A** 41,000 TXV CSPH*4812A** 41,000 TDR&TXV CV(A,X) CSPH*4812A** 41,000 TDR&TXV MVB CSPH*4812A** 41,500 TXV FV4BNB006 42,500 TDR&TXV FV4BNF003 40,500 TDR&TXV FV4BNF005 41,500 TDR&TXV FX4CN(B,F)042 41,500 TDR&TXV FX4CN(B,F)048 42,500 TDR&TXV FY4ANF042 41,000 TDR&TXV FY4ANF048 42,000 TDR&TXV *CAP**4821A** 46,000 TXV CAP**4817A** 44,000 TDR&TXV CV(A,X) CAP**4817A** 45,000 TXV CAP**4821A** 45,000 TDR&TXV CV(A,X) CAP**4821A** 45,000 TDR&TXV MVB CAP**4821A** 45,000 TDR&TXV MVB CAP**4824A** 45,500 TDR&TXV CV(A,X) CAP**4824A** 45,000 TDR&TXV MVB CAP**4824A** 46,000 TXV CAP**6021A** 46,500 TDR&TXV CV(A,X) CAP**6021A** 45,000 TDR&TXV MVB CAP**6021A** 46,000 TXV CAP**6024A** 46,500 TDR&TXV CV(A,X) CAP**6024A** 46,000 TDR&TXV MVB CAP**6024A** 47,000 TXV CNPF*4818A** 45,000 TXV See notes on pg

14 COMBINATION RATINGS (CONT.) Unit Size --- Voltage, Series Indoor Factory SEER Total Cap. Supplied Standard BTUH TDR Enhancement Rating EER Furnace CNPH*4821A** 45,000 TDR&TXV CV(A,X) CNPH*4821A** 45,500 TDR&TXV CV(A,X) CNPH*4821A** 45,000 TDR&TXV MVB CNPH*4821A** 45,000 TDR&TXV MVB CNPH*4821A** 46,000 TXV CNPH*6024A** 46,000 TDR&TXV CV(A,X) CNPH*6024A** 46,000 TDR&TXV CV(A,X) CNPH*6024A** 46,000 TDR&TXV MVB CNPH*6024A** 46,000 TDR&TXV MVB CNPH*6024A** 47,000 TXV CNPV*4821A** 45,000 TDR&TXV CV(A,X) CNPV*4821A** 45,000 TDR&TXV MVB CNPV*4821A** 46,000 TXV CNPV*4824A** 45,000 TDR&TXV CV(A,X) CNPV*4824A** 45,000 TDR&TXV MVB CNPV*4824A** 46,000 TXV CNPV*6024A** 46,000 TDR&TXV CV(A,X) CNPV*6024A** 46,000 TDR&TXV MVB CNPV*6024A** 47,000 TXV CSPH*4812A** 45,500 TDR&TXV CV(A,X) CSPH*4812A** 45,000 TDR&TXV MVB CSPH*4812A** 46,000 TXV CSPH*6012A** 46,000 TDR&TXV CV(A,X) CSPH*6012A** 46,000 TDR&TXV MVB CSPH*6012A** 47,000 TXV FV4BNB006 47,000 TDR&TXV FV4BNF005 46,500 TDR&TXV FX4CN(B,F)048 47,000 TDR&TXV FX4CN(B,F)060 47,500 TDR&TXV FY4ANB060 46,500 TDR&TXV FY4ANF048 46,000 TDR&TXV *CAP**6024A** 57,500 TXV CAP**6021A** 56,000 TDR&TXV CV(A,X) CAP**6021A** 56,000 TDR&TXV MVB CAP**6021A** 56,000 TDR&TXV MVB CAP**6021A** 56,500 TXV CAP**6024A** 56,500 TDR&TXV CV(A,X) CAP**6024A** 56,500 TDR&TXV CV(A,X) CAP**6024A** 56,500 TDR&TXV MVB CNPH*6024A** 56,000 TDR&TXV CV(A,X) CNPH*6024A** 56,500 TDR&TXV CV(A,X) CNPH*6024A** 57,000 TXV CNPV*6024A** 56,000 TDR&TXV CV(A,X) CNPV*6024A** 56,500 TDR&TXV CV(A,X) CNPV*6024A** 57,000 TXV CSPH*6012A** 56,500 TDR&TXV CV(A,X) CSPH*6012A** 56,500 TDR&TXV CV(A,X) CSPH*6012A** 56,500 TDR&TXV CV(A,X) CSPH*6012A** 57,500 TXV FV4BNB006 57,000 TDR&TXV FX4CN(B,F)060 58,000 TDR&TXV FY4ANB060 56,500 TDR&TXV * Tested combination { In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR. EER Energy Efficiency Ratio SEER Seasonal Energy Efficiency Ratio TDR Time --- Delay Relay TXV Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are affected. 14

15 DETAILED COOLING CAPACITIES# Evaporator Air CFM EWB CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 18A31 Outdoor Section With 18 Indoor Section {{ {{ {{ *CAP**1814A** CAP**2414A** CAP**2417A** CNPF*2418A** CNPH*2417A** CNPV*1814A** CNPV*2414A** CNPV*2417A** CSPH*2412A** FF1ENP FF1ENP See notes on pg. 20 Capacity Power Furnace Capacity Power Furnace FV4BNF FX4CNF FX4CNF FY4ANF FY4ANF CAP**1814A** CV(A,X) CAP**2414A** CV(A,X) CNPH*2417A** CV(A,X) CNPV*1814A** CV(A,X) CNPV*2414A** CV(A,X) CSPH*2412A** CV(A,X) CAP**2417A** CV(A,X) Capacity Power Furnace CNPH*2417A** CV(A,X) CNPV*2417A** CV(A,X) CSPH*2412A** CV(A,X) CNPH*2417A** MVB CSPH*2412A** MVB CAP**2417A** MVB CNPH*2417A** MVB CNPV*2417A** MVB CSPH*2412A** MVB CNPH*2417A** MVB CSPH*2412A** MVB

16 DETAILED COOLING CAPACITIES# (CONT.) Evaporator Air CFM EWB CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 24A31 Outdoor Section With 24 Indoor Section {{ {{ {{ *CAP**2414A** CAP**2417A** CAP**3014A** CAP**3017A** CNPF*2418A** CNPH*2417A** CNPH*3017A** CNPV*2414A** CNPV*2417A** CNPV*3014A** CNPV*3017A** CSPH*2412A** CSPH*3012A** FF1ENP FF1ENP FV4BNF FV4BNF FX4CNF See notes on pg. 20 Capacity Power Furnace Capacity Power Furnace FX4CNF FY4ANF FY4ANF CAP**2414A** CV(A,X) CAP**3014A** CV(A,X) CNPH*2417A** CV(A,X) CNPH*3017A** CV(A,X) CNPV*2414A** CV(A,X) CNPV*3014A** CV(A,X) CSPH*2412A** CV(A,X) CSPH*3012A** CV(A,X) CAP**2417A** CV(A,X) CAP**3017A** CV(A,X) CNPV*2417A** CV(A,X) CNPV*3017A** CV(A,X) CSPH*2412A** CV(A,X) CSPH*3012A** CV(A,X) CSPH*2412A** CV(A,X) Capacity Power Furnace CSPH*3012A** CV(A,X) CSPH*2412A** CV(A,X) CSPH*3012A** CV(A,X) CSPH*3012A** CV(A,X) CNPH*2417A** MVB CNPH*3017A** MVB CSPH*2412A** MVB CSPH*3012A** MVB CAP**2417A** MVB CAP**3017A** MVB CNPV*2417A** MVB CNPV*3017A** MVB CSPH*2412A** MVB CSPH*3012A** MVB CSPH*3012A** MVB CSPH*3012A** MVB CSPH*3012A** MVB CSPH*3012A** MVB

17 DETAILED COOLING CAPACITIES# (CONT.) Evaporator Air CFM EWB CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 245ABA330A32 Outdoor Section With CAP**3014A** Indoor Section {{ {{ {{ Capacity Power Furnace *CAP**3014A** CAP**3017A** CAP**3614A** CAP**3617A** CAP**3621A** CNPF*3618A** CNPH*3017A** CNPH*3617A** CNPV*3014A** CNPV*3017A** CNPV*3617A** CNPV*3621A** CSPH*3012A** CSPH*3612A** FF1ENP FF1ENP FV4BNF FV4BNF FV4BNF FX4CN(B,F) FX4CNF FY4ANF FY4ANF CAP**3014A** CV(A,X) CAP**3614A** CV(A,X) CNPH*3017A** CV(A,X) CNPH*3617A** CV(A,X) Capacity Power Furnace CNPV*3014A** CV(A,X) CSPH*3012A** CV(A,X) CSPH*3612A** CV(A,X) CAP**3017A** CV(A,X) CAP**3617A** CV(A,X) CNPV*3017A** CV(A,X) CNPV*3617A** CV(A,X) CAP**3621A** CV(A,X) CNPV*3621A** CV(A,X) CNPH*3017A** MVB CNPH*3617A** MVB CSPH*3012A** MVB CSPH*3612A** MVB CAP**3017A** MVB CAP**3617A** MVB CNPV*3017A** MVB CNPV*3617A** MVB CAP**3621A** MVB CNPV*3621A** MVB See notes on pg

18 DETAILED COOLING CAPACITIES# (CONT.) Evaporator Air CFM EWB CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 36A31 Outdoor Section With 36 Indoor Section {{ {{ {{ Power Furnace *CAP**3617A** CAP**3614A** CAP**3621A** CAP**4221A** CAP**4224A** CNPF*3618A** CNPH*3617A** CNPH*4221A** CNPV*3617A** CNPV*3621A** CNPV*4221A** CSPH*3612A** CSPH*4212A** FF1ENP FV4BNB FV4BNF FV4BNF FV4BNF FX4CN(B,F) FX4CN(B,F) FY4ANF FY4ANF CAP**3614A** CV(A,X) CNPH*3617A** CV(A,X) CNPH*4221A** CV(A,X) CSPH*3612A** CV(A,X) CSPH*4212A** CV(A,X) Capacity Capacity Power Furnace CAP**3617A** CV(A,X) CNPV*3617A** CV(A,X) CAP**3621A** CV(A,X) CAP**4221A** CV(A,X) CNPV*3621A** CV(A,X) CNPV*4221A** CV(A,X) CAP**4224A** CV(A,X) CAP**4224A** MVB CNPH*3617A** MVB CNPH*4221A** MVB CSPH*3612A** MVB CSPH*4212A** MVB CAP**3617A** MVB CNPH*4221A** MVB CNPV*3617A** MVB CAP**3621A** MVB CAP**4221A** MVB CNPV*3621A** MVB CNPV*4221A** MVB See notes on pg

19 DETAILED COOLING CAPACITIES# (CONT.) Evaporator Air CFM EWB CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 42A301Outdoor Section With 42 Indoor Section {{ {{ {{ Capacity Power Furnace *CAP**4221A** CAP**4224A** CAP**4817A** CAP**4821A** CAP**4824A** CNPF*4818A** CNPH*4221A** CNPH*4821A** CNPV*4221A** CNPV*4821A** CNPV*4824A** CSPH*4212A** CSPH*4812A** FV4BNB FV4BNF FV4BNF FX4CN(B,F) FX4CN(B,F) FY4ANF FY4ANF CNPH*4221A** CV(A,X) CNPH*4821A** CV(A,X) CSPH*4212A** CV(A,X) CSPH*4812A** CV(A,X) CAP**4817A** CV(A,X) CAP**4221A** CV(A,X) CAP**4821A** CV(A,X) Capacity Power Furnace CNPV*4221A** CV(A,X) CNPV*4821A** CV(A,X) CAP**4224A** CV(A,X) CAP**4824A** CV(A,X) CNPV*4824A** CV(A,X) CAP**4224A** MVB CAP**4824A** MVB CNPH*4221A** MVB CNPH*4821A** MVB CNPV*4824A** MVB CSPH*4212A** MVB CSPH*4812A** MVB CAP**4817A** MVB CAP**4221A** MVB CAP**4821A** MVB CNPV*4221A** MVB CNPV*4821A** MVB See notes on pg

20 DETAILED COOLING CAPACITIES# (CONT.) Evaporator Air CFM EWB CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 48A31 Outdoor Section With 48 Indoor Section {{ {{ {{ Capacity Power Furnace *CAP**4821A** CAP**4817A** CAP**4824A** CAP**6021A** CAP**6024A** CNPF*4818A** CNPH*4821A** CNPH*6024A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CSPH*4812A** CSPH*6012A** FV4BNB FV4BNF FX4CN(B,F) FX4CN(B,F) FY4ANB FY4ANF CAP**4817A** CV(A,X) CNPH*4821A** CV(A,X) CNPH*6024A** CV(A,X) CSPH*4812A** CV(A,X) CSPH*6012A** CV(A,X) CAP**4821A** CV(A,X) CAP**6021A** CV(A,X) CNPH*4821A** CV(A,X) Capacity Power Furnace CNPH*6024A** CV(A,X) CNPV*4821A** CV(A,X) CAP**4824A** CV(A,X) CAP**6024A** CV(A,X) CNPV*4824A** CV(A,X) CNPV*6024A** CV(A,X) CAP**4821A** MVB CAP**6021A** MVB CNPH*4821A** MVB CNPH*6024A** MVB CNPV*4821A** MVB CSPH*4812A** MVB CSPH*6012A** MVB CAP**4821A** MVB CNPH*4821A** MVB CNPH*6024A** MVB CAP**4824A** MVB CAP**6024A** MVB CNPV*4824A** MVB CNPV*6024A** MVB See notes on pg

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24ABC6 Comfortt16 Air Conditioner with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Legacy-RNC eries Air Conditioner with Puronr Product Data the environmentally sound refrigerant A05233 Bryant s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons 116B Legacyt Line 16 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS Product Data Bryant Air Conditioners with refrigerant provide a collection of features unmatched by any other

More information

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES: (60 Hz) 13 SEER Air Conditioner Sizes 018 --- 060 Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched by

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCD

More information

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant Sizes 018 thru 060 Model 38ETG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling

More information

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton PRODUCT NUMBER NOMENCLATURE 14 SEER Air Conditioner with Refrigerant PA14 N C 018 00G B A Series Variations Electrical Supply N 208/230 60 1 00G Variations C Nominal Capacity 018 1 1/2Ton 024 2Tons 030

More information

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS Product Data 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 The 38CKS Air Conditioner is designed for superior performance durability in harsh environments. The product achieves

More information

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS. Performancet 16 2 --- Stage Heat Pump with Puronr Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with Puron r refrigerant provide a collection of features

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable cooling performance.

More information

Product Data. Efficiency. S S Reliability

Product Data. Efficiency. S S Reliability 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH14 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES: AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS (018-060) Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

A 14 SEER Heat Pump with R---410A Refrigerant Series

A 14 SEER Heat Pump with R---410A Refrigerant Series MODEL NUMBER NOMENCLATURE PH14 N B 018 00G B A 14 SEER Heat Pump with R---410A Refrigerant Series Electrical Supply N=208/230---1 P=208/230---3 E=460/3 B R---410A Nominal Capacity 018 1 1/2Tons 024 2Tons

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 114CNC Legacyt Line Air Conditioner for Coastal Applications with r Refrigerant 1--1/2 To 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14.0 SEER / 11.0 13.5 EER S Microtube

More information

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS. (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1 --- 1/2 to 5 Nominal Tons) Product Data The Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter

More information

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Product Data Bryant Heat Pumps with Puronr refrigerant provide a collection of features unmatched by any other family

More information

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data PA13NA PA13PA FEATURES AND BENEFITS PA13NA PA13PA 13 SEER Split---System Air Conditioner With R---410A Refrigerant Single & Three Phase 1 --- 1/2 To 5 Tons Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S BH13NA 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH13 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38EZG (60 Hz) Air Conditioner with Puron Sizes 018 thru 060 Copyright 2003 Carrier Corporation Model 38EZG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet,

More information

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC 50 Hz Air Conditioner Sizes 018 thru 060 Model 38CKC 50 Hertz energyefficient air conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. CA13NA 018 060 Base Series Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s non -ozone depleting refrigerant. INDUSTRY LEADING FEATURES / BENEFITS Efficiency

More information

Advance Product Data

Advance Product Data Comfort 14 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Advance Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched

More information

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant, AVAILABLE SIZES: CERTIFICATION: Nominal sizes available from 018 through 060 to meet the needs of residential and light commercial applications. All models are listed with UL, c-ul, ARI, CEC, and CSA-

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4**C Comfort 14 Heat Pump for Coastal Applications with r Refrigerant 1---1/5 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5 -- 11.7 EER / 8.2 HSPF

More information

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24AHA4 Performance Series Air Conditioner with Refrigerant 1-1/2 to 5 Nominal Tons Product Data Carrier air conditioners with refrigerant provide a collection of features unmatched by any other family

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38BYG (60 Hz) 12 SEER Heat Pump s 018 thru 060 The 38BYG Outdoor s of Split- Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER

More information

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1 12 SEER ELECTRIC AIR CONDITIONER 563G (60 Hz) Sizes 018 thru 060 Model 563G Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38BRC (60 Hz) Air Conditioner Sizes 024 thru 060 Model 38BRC Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into

More information

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5 12 SEER AIR CONDITIONER 563C Sizes 018 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

INDUSTRY LEADING FEATURES 2 5 / BENEFITS Infinityr 19 2 --- Stage Heat Pump with Puronr Refrigerant 2to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

Installation Instructions

Installation Instructions MODEL LEGACYT ERIE R-22 AIR CONDITIONER IZE 018 TO 060 1-1/2 TO 5 NOMINAL TON Installation Instructions TM INDUTRY LEADING FEATURE / BENEFIT Efficiency ound Comfort Reliability Durability 13 EER / 11.0

More information

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Product Data 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Carrier s WeatherMaker 38TXA with Puron provides a completely unique collection of features which cannot be matched by

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound 24VNA0 Infinityr Variable Speed Air Conditioner with Greenspeedr Intelligence 2to5NominalTons Product Data Carrier s 24VNA0 with Greenspeed R Intelligence is a variable speed cooling product providing

More information

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability 25HPB6 Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Tons Product Data the environmentally sound refrigerant Carrier heat pumps with Puronr refrigerant provide a collection of features

More information

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4 DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) 550A (60 Hz) Sizes 024 thru 060 Bryant s Quantum Plus 550A with Puron provides a completely unique collection of features which cannot be matched by any

More information

Product Data. Efficiency

Product Data. Efficiency BH14NB SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5-11.7 EER / 8.2 HSPF S Microtube Technologyt refrigeration

More information

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: ELECTRICAL RANGE: FAN MOTOR: CABINET: UNIT

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11 12 SEER ELECTRIC AIR CONDITIONER 563C (60 Hz) Sizes 024 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES Product Data Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant Sizes 024 thru 060 Carrier s Performance 14 Air Conditioners with Puron refrigerant provide a collection of features unmatched

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4 Comfort 14 Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38YCC 50 Hz Heat Pump Sizes 024 thru 060 The 38YCC 50 Hertz Outdoor s of Split-System Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES 10 SEER HEAT PUMP UNIT 661C Sizes 018 thru 060 The 661C Outdoor Section of Split- Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER up to 11.5

More information

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES Product Data 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant Sizes 018 thru 060 Carrier s technological leadership has risen to a new level with the development of the 38EYG Heat Pump, the outdoor

More information

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: With SEER of at least 10.0 and HSPF of 6.8,

More information

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t Infinityr 15 Heat Pump with Puronr Refrigerant 2to4NominalTons(Sizes24---48) Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

Advance Product Data

Advance Product Data Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably

More information

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8 ELECTRIC AIR CONDITIONER 597C (60 Hz) Sizes 018 thru 060 The Reliant AeroQuiet System (AQS) consists of 3 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening

More information

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet 2---tage Air Conditioner with r Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with r refrigerant provide a collection of features unmatched

More information

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier Heat Pumps with Puronr refrigerant provide a collection of features

More information

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

R 410A Ducted Horizontal Air Conditioner

R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS, 208/230

More information

Advance Product Data

Advance Product Data EVOLUTION R V VARIABLE SPEED AIR CONDITIONER WITH PURONr REFRIGERANT 2, 3, AND 4-TON (5-TON COMING Q4 2014) Advance Product Data The Evolution V air conditioner offers high -efficiency variable speed performance

More information

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060 Product Data Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant Sizes 018 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS,

More information

697C (60 HZ) Sizes 018 thru 060

697C (60 HZ) Sizes 018 thru 060 SPLIT-SYSTEM HEAT PUMP UNITS 697C (60 HZ) s 018 thru 060 The AeroQuiet System (AQS) consists of 4 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and

More information

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling PAYNE Heating & ELECTRIC CONDITIONER 710A (60 Hz) Sizes 018 thru 060 Model 710A Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable summer cooling performance.

More information

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3 DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT 652A Sizes 018 thru 060 TM The 652A split-system outdoor unit is a 12 SEER heat pump (with efficiencies up to 14.0 SEER). Homeowners will appreciate this

More information

Product Data. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S S S Sound S S S S Comfort S

Product Data. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S S S Sound S S S S Comfort S 187B (2-5 Ton) EVOLUTIONr AIR CONDITIONER WITH PURONr REFRIGERANT Product Data Bryant s air conditioners with r refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Advance Product Data

Advance Product Data EVOLUTION R EXTREME VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT (2-5 Ton) Advance Product Data Bryant s Evolutionr Extreme is a breakthrough product providing up to 13 HSPF heating efficiency and

More information

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Product Data 38EYA (60Hz) 12 SEER Split- Cube Heat Pump with Puron Refrigerant Sizes 018 thru 060 FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Carrier s technological leadership has risen to a

More information

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant Product Data 38YXA (60Hz) Deluxe 13 SEER Split- Heat Pump with Puron (R-410A) Refrigerant Sizes 024 thru 060 INTRODUCING THE WEATHERMAKER 38YXA HEAT PUMP FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

More information

Product Data. 24ACB7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ACB7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS 24ACB7 Performancet 17 2---tage Air Conditioner with r Refrigerant 2to5Tons Product Data Carrier Air Conditioners with r refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. 018---060 Base eries Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1 QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT 650A (60 Hz) Sizes 024 thru 060 The Quantum Plus line of split-system outdoor units has been expanded to include the Model 650A 13 SEER heat pump (with

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS MODEL PREFERRED ERIE AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TON Product Data the environmentally sound refrigerant Bryant Air Conditioners with r refrigerant provide a collection of

More information

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S Durability. WeatherArmort protection package: S S S

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S Durability. WeatherArmort protection package: S S S Comfortt13 Air Conditioner for Coastal Applications with r Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with r refrigerant provide a collection of features

More information

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES AVAILABLE SIZES: 18,000 to 60,000 Btu CERTIFICATION: U.L., c-ul, ARI and CEC Listed ELECTRICAL RANGE: 208 230v, 60 Hertz, 1 Phase COMPRESSOR PROTECTION: Each compressor is protected with internal temperature-

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S. CA13NA 024 060 Base eries Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data. 24AAA5 Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 24AAA5 Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS. 24AAA5 ingle---tage Air Conditioner with r Refrigerant 1 --- 1/2 To 5 Tons Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability 14.0 EER / 11.7 12.2 EER (based on tested combination)

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (Sizes )

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (Sizes ) 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (izes 018-060) Product Data Bryant s Air Conditioners with Puronr refrigerant provide a collection of features unmatched

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126CNA PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126CNA PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS MODEL 126CNA PREFERRED ERIE AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TON Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other

More information

Product Data. Efficiency

Product Data. Efficiency PH16NC PLIT YTEM HEAT PUMP WITH R -410A REFRIGERANT 1-1/2 TO 5 NOMINAL TON Product Data This product has been designed and manufactured to meet Energy tarr criteria for energy efficiency when matched with

More information

INDUSTRY LEADING FEATURES 1-1/2 5 / BENEFITS

INDUSTRY LEADING FEATURES 1-1/2 5 / BENEFITS 114CNA Legacyt Line 14 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data. CA14NA Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA14NA Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS. CA14NA ingle---tage Air Conditioner with r Refrigerant 1 --- 1/2 To 5 Tons Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability 14.0 EER / 11.7 12.0 EER (based on tested combination)

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Product Data. Efficiency S. S S Indoor air quality accessories available Comfort S System supports Edger Thermidistatt or standard

Product Data. Efficiency S. S S Indoor air quality accessories available Comfort S System supports Edger Thermidistatt or standard 24ACC4 Comfortt14 Air Conditioner with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BA15NA SINGLE -STAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BA15NA SINGLE -STAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS. BA15NA INGLE -TAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TON Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability 14.0 EER / 11.7 13.5 EER (based on tested combination)

More information

Product Data. CA16NW Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. CA16NW Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS CA16NW ingle---tage Air Conditioner with r Refrigerant 1 --- 1/2 To 5 Tons Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability Up to 16.5 EER / 12.2 13.0 EER Microtube Technologyt

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

SERIES 15 HEAT PUMP WITH PURON

SERIES 15 HEAT PUMP WITH PURON MODEL PREFERRED ERIE 15 HEAT PUMP WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TON Product Data the environmentally sound refrigerant Bryant s heat pumps with r refrigerant provide a collection of features

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information