1 Applications Engineering Notes Document Title Document Number Revision Number Product Specification and Qualification Test Report: IBC Brand Fiber Optic Connector Cleaner MT38 II AEN-1146 Issue Effective Date June 30, 2014

2 1.0 Introduction 1.1 Purpose 1.2 Scope This test report is the abbreviated qualification of the IBC Brand Fiber Optic Connector Cleaner MT38 II cleaning tools based on the conclusions from AEN-1142 (Cleaner MPO II). Contamination, impact, durability, and life cycle testing was performed to verify functionality of the new tip. Three cleaners were subjected to the contamination, durability, life cycle and five cleaners for the impact testing as shown in Table 1. Each of these tests (with the exception of impact testing) was repeated until the connector passed the inspection, up to three cleaning iterations. The end faces were visually inspected all fibers and pictures of fibers were recorded. Typical results for photographs representative of each test are shown in Appendix A. For each trial, the following photographs were taken: Initial clean connector endface Contaminated endface Cleaned endface 1.3 Abstract The IBC Brand Fiber Optic Connector Cleaner MT38 II cleaning tools were tested against various contaminants and subjected to impact, durability, and life cycle testing. All cleaners tested proved to be effective cleaning devices with the necessary durability to withstand simulated field conditions. The results showed that the MT38 II cleaning tools performed very well to be considered as US Conec s recommended method of cleaning MT based D38999 and other hardened connectors. 1.4 Product Description The IBC Brand Fiber Optic Connector Cleaner MT38 II cleaning tool, shown in Figure 1, is designed for cleaning the fiber arrays on MT based D38999 and other hardened connectors. 2 Figure 1: The IBC Brand Fiber Optic Connector Cleaner MT38 II

3 2.0 Test Requirements The tests below are required for the qualification of The IBC Brand Fiber Optic Connector Cleaner MT38 II: TEST PROCEDURE REQUIREMENT PERFORMANCE Contamination Keyence Digital Videoscope using the Non Removable pass/fail criteria Three cleaners for each test with connector adapter and cleaner cap against flat connectors according to IEC Using the following contaminants: Arizona road dust and Vegetable oil Inspection Criteria: IEC See Table 2. Acceptable performance for all contaminants Impact Release 5 cleaners from a height of 1.5m for 10 repetitions per cleaner with varied angles. Verify cleaner operation. No functional damage at 1.5m No functional damage at 1.5m Durability Cycle three cleaners through cleaning operation on connectors with adapters repeating 500 cycles. Verify function with a single dust contamination. Inspect for damage. No functional damage No evidence of damage Life Cycle Count number of cycles until the cloth end. > 525 cycles MT38 II cleaner > 525 cycles 1 Note - only road dust, vegetable oil, <70% IPA residue, and NaCl residue are required by IEC All other contaminants are a customer specific requirement. Table 1: Testing Summary 3

4 Allowable Visible Contamination Zone Description Diameter Scratch-Width Non-Removables Area Near A Core (SMF only) < 25 µm None None Area Near No limit < 3 µm 4 NR s < 5 µm Core (MMF < 65 µm None > 3 µm only) B Cladding (SMF only) Cladding (MMF only) 3.0 Test Results Summary 25 µm to 120 µm 65 µm to 115 µm No limit < 3 µm None > 3 µm No limit < 5 µm Table 2: Inspection Criteria for Contamination Testing NRs < 2 µm are acceptable 5 NRs 2-5 µm NRs < 2 µm are acceptable Total of 5 NRs 2-5 µm Below is the summary of the qualification tests performed and the performance observed. 3.1 Contamination Test Results The IBC Brand Cleaner MT38 II proved to be effective for both Arizona road dust and Vegetable oil. When used only as a dry method, the cleaner adequately removed contaminants on the second cleaning pass for Arizona road dust and third pass for Vegetable oil in both male and female connector. 3.2 Impact Test All five cleaners tested at the 1.5 meters drop passed all 10 repetitions with no functional damage. 3.3 Durability Test All ten cleaners completed the 500 cleaning cycles with no evident damage, and all contamination was removed by the second cleaning pass. 4

5 3.4 Life Cycle Test Appendix A: The number of cleaning cycles per MT38 II cleaner has met and exceeded the life cycle requirements. Typical Results - Contamination Photographs for MT38 II Arizona Road Dust MM Initial Contaminated 1 st Pass 2 nd Pass Vegetable Oil MM Initial Contaminated 1 st Pass 2 nd Pass 3 srd Pass 5

Applications Engineering Notes

Applications Engineering Notes Applications Engineering Notes Document Title Document Number US Conec Recommended Cleaning Procedure for Multifiber and Single Fiber Connectors and Mating Adapters AEN-1902 Revision Number 2.0 Effective

More information

The True Value of Connector Inspection: New Challenges and Best Practices

The True Value of Connector Inspection: New Challenges and Best Practices The True Value of Connector Inspection: New Challenges and Best Practices Vincent Racine Product Line Manager August 2011 1 Table of contents 1 Best Practices 2 Connector Inspection Tools 3 Connector Inspection

More information

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors 2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors April 2016 www.sticklerscleaners.com STICKLERS 2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

MOST EFFECTIVE METHOD FOR WIPING A FIBRE

MOST EFFECTIVE METHOD FOR WIPING A FIBRE MOST EFFECTIVE METHOD FOR WIPING A FIBRE Step 1: Pull & fold a new wipe Step 2: Apply the cleaning fluid Step 3: Wipe the fiber in single direction Avoid oversaturating the wipe Insert the fiber into the

More information

Fiber Optic Connector Cleaning Solutions

Fiber Optic Connector Cleaning Solutions Fiber Optic Connector Cleaning Solutions www.usconec.com Table of Contents Fiber Optic Cleaning Guide The Importance of Cleaning 3 Good Cleaning Practices 3 Single Fiber Cleaner Instructions 4 Multi-fiber

More information

Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector

Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector March 7, 2011 Toshiaki Satake, Brian Teague, Jillcha Wakjira, Alan Ugolini and Darrell Childers US

More information

Multi fiber connector: Visual inspection and cleaning guide

Multi fiber connector: Visual inspection and cleaning guide Multi fiber connector: HUBER+SUHNER AG Fiber Optics FOBUFiber connectivity Indoor FCI DOC-0000761071 Date: 26 August 2016 Page 1 of 8 TABLE OF CONTENTS GENERAL INFORMATION 2 VISUAL INSPECTION 3 MICROSCOPE

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

FIBER OPTIC CONNECTOR CLEANERS

FIBER OPTIC CONNECTOR CLEANERS FIBER OPTIC CONNECTOR CLEANERS FIBER OPTIC CONNECTOR CLEANERS TABLE OF CONTENTS Introduction Fiber Optic Connector Cleaning Tools Page 2 Single Fiber Cleaning Tools NEOCLEAN E Refillable Cleaners IBC Brand

More information

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction.

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction. White Paper: Fiber Contamination, Cleaning and Inspection. Introduction. Despite industry best practice of inspecting and cleaning fiber optic endfaces, contaminated connections remain the number one cause

More information

Cleaning of fiber optic connectors

Cleaning of fiber optic connectors Cleaning of fiber optic connectors HUBER+SUHNER AG Fiber Optics DOC-0000415541 March 2018 Page 1 of 20 Table of contents 1. General guidelines... 2 2. Cleaning of ODC connectors... 4 3. Cleaning of Q-ODC-12

More information

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies Preface...Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2 Target Audience... 1 2 1.3 Structure and Use of This Document...1 2 1.4 Changes from Issue 2 of GR-326-CORE... 1 3 1.5 Requirements

More information

White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure

White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure White Paper: Standard-Compliant Certification & Best Practices

More information

White Paper Fiber optic connections: check and clean first, then connect!

White Paper Fiber optic connections: check and clean first, then connect! White Paper Fiber optic connections: check and clean first, then connect! How installers ensure the quality of their work Fiber optic connections: check and clean first, then connect! How installers ensure

More information

INDUSTRY STATS SNAPSHOT

INDUSTRY STATS SNAPSHOT INDUSTRY STATS SNAPSHOT HTI Martin Technical Research Survey of 89 network owners and network contactors study on network failure. 98% of Network Contractors experienced fiber failures during the installation

More information

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification Notice Copyright Every effort was made to ensure that the information in this document

More information

Fiber Optic Cleaning Overview. Prepared by Steve Lytle, Westover Scientific March 10 th, 2004

Fiber Optic Cleaning Overview. Prepared by Steve Lytle, Westover Scientific March 10 th, 2004 Fiber Optic Cleaning Overview Prepared by Steve Lytle, Westover Scientific March 10 th, 2004 Overview This presentation provides an overview as to cleaning techniques that are currently available to the

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Ensuring Cabling Performance in the Customer-Owned Outside Plant Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for

More information

SECTION TESTING OF FIBER OPTIC CABLES

SECTION TESTING OF FIBER OPTIC CABLES SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication ISO/IEC 14763-3 CONSOLIDATED VERSION Edition 2.1 2018-08 colour inside Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling INTERNATIONAL

More information

Jul07 Rev C

Jul07 Rev C Product Specification 108-2167 11Jul07 Rev C MPO and MPO SECURE Multimode Fiber Optic Connector and Adapter 1. SCOPE 1.1. Content This specification, which is based on GR-1435-CORE, covers the performance,

More information

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne Accelerating NBN fiber testing and workforce Performance. Tom Ronan Marketing Lead Fiber Optics Melbourne Agenda Network Elements and Parameters Distributed Fiber Network (DFN) Construction Network Activation

More information

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

Fibre Specification Standards

Fibre Specification Standards Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair

More information

AS/NZS ISO/IEC :2012

AS/NZS ISO/IEC :2012 AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical

More information

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,

More information

Connections You Can Count On.

Connections You Can Count On. Connections You Can Count On. XPRESS ULTRA FIBER CONNECTOR PRODUCT GUIDE - CLEANING & INSPECTION - TESTING AND TROUBLE SHOOTING - XPRESS ULTRA FIBER CONNECTORS - INSTALLATION KITS Connections You Can Count

More information

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Fiber Optic Connector Cleaning and Inspection Kit Instructions Instruction Sheet 860376037 Rev E, March 2018 Fiber Optic Connector Cleaning and Inspection Kit Instructions General This instruction sheet describes the use of the CommScope Fiber Optic Connector Cleaning

More information

SECTION TESTING OF FIBER OPTIC CABLES

SECTION TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Best Practice Briefing

Best Practice Briefing Best Practice Briefing Fiber Optic Connector Handling, Inspection, andcleaning microwave photonic systems Expand Your RF Horizons Briefing Overview Personnel Safety & Best Practices Insertion Loss (IL)

More information

AGENDA Contamination Working with Optical Grade Wipes Sticks & Clickers Optical Grade Fluids & Dusters Best Practices Wrap Up AGENDA Contamination Working with Optical Grade Wipes Sticks & Clickers Optical

More information

ACCESS Master MT9085 Series. Product Introduction

ACCESS Master MT9085 Series. Product Introduction ACCESS Master MT9085 Series Product Introduction Strengthen of MT9085 Series: 1/5 All Optical Fiber Evaluation Functions in One Tester The ACCESS Master MT9085 series is an all-inone tester with OTDR,

More information

Core Alignment All In One Fusion Splicer

Core Alignment All In One Fusion Splicer Economical Solution for Integrated Fiber Preparation Tool Demand. Core Alignment All In One Fusion Splicer Single Optical Fiber Fusion Splicer US Patent /9 2,09 The Revolution of a Splicer Integrated to

More information

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures ON THE BUTTON A reference guide to environmental ratings used for push button enclosures A REFERENCE GUIDE TO KEY TOPICS IN PUSH BUTTON SELECTION AND SAFETY CONTENTS I. INTRODUCTION...............................

More information

Advancing Fiber Optic Connectivity

Advancing Fiber Optic Connectivity Advancing Fiber Optic Connectivity Fusion Spice-On Connectors by Brad Everette, America Ilsintech, Dallas, TX and Seung-Min Lee, Ilsintech, Daejeon, South Korea Presentation Overview Advancements in Fiber

More information

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

/Mar/2014 Rev A

/Mar/2014 Rev A Qualification Test Report 501-93038 21/Mar/2014 Rev A MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC 1. INTRODUCTION 1.1 Purpose Tests performed on MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC,

More information

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna enna (FTTA) Installation and Maintenance Testing

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61753-1-3 Edition 1.0 2014-05 Fibre optic interconnecting devices and passive components Performance standard Part 1-3: General and guidance for single-mode fibre optic connector

More information

Suits SC, ST & FC 2.5mm PC & APC polish 525+ uses. Suits HFOCs in Optitip systems and other FTTx applications

Suits SC, ST & FC 2.5mm PC & APC polish 525+ uses. Suits HFOCs in Optitip systems and other FTTx applications Fibre Optic Cleaning & Consumables Fibre optic cleaning is one of the most basic, important and often overlooked procedures for maintaining fibre optic networks. FOS offers a comprehensive selection of

More information

Draft ES V1.1.1 ( )

Draft ES V1.1.1 ( ) Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing

More information

Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates

Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates Brian Teague Product Line Manager 18 November 2016 Program Agenda 1. Do It

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61754-7 INTERNATIONAL STANDARD Edition 3.0 2008-03 Fibre optic interconnecting devices and passive components Fibre optic connector interfaces INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE U

More information

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 100 783 V1.2.1 (2004-08) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor

More information

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on

More information

Fibrlok II 2529 Universal Optical Fiber Splice

Fibrlok II 2529 Universal Optical Fiber Splice Fibrlok II 2529 Universal Optical Fiber Splice Technical Report December 1994 Issue 1, 78-8098-3415-9 1 1.0 Product Description The 3M brand Fibrlok II 2529 Universal Optical Fiber Splice is a high performance,

More information

Licensing of FPGA-based Safety Platform RadICS: Case Study

Licensing of FPGA-based Safety Platform RadICS: Case Study Licensing of FPGA-based Safety Platform RadICS: Case Study Anton Andrashov, Head of International Projects Division 10th International Workshop on the Application of FPGAs in NPPs December 4-6 2017, Gyeongju,

More information

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY White Paper BACKGROUND: Safety is paramount in the home appliance industry. Due to the possibility of human mis-application, over-current, or short circuit

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 101 263 V1.2.1 (2004-07) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems for

More information

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona Architectural Testing PRODUCT PERFORMANCE TEST REPORT Report No.: D7226.01-121-24 Test Date: May 29, 2014 Rendered to: Natural Light Energy Systems Phoenix, Arizona PRODUCT TYPE: Tubular Daylight Device

More information

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA 1.0 INTRODUCTION This report presents the results of an investigation of the external fire resistance characteristics of the VELUX FCM Deck Mounted Skylight roof covering system in general accordance with

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 14763-3 First edition 2006-06 Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling Reference number ISO/IEC

More information

CLASSIFICATION Constructional Data Report (CDR)

CLASSIFICATION Constructional Data Report (CDR) CLASSIFICATION Constructional Data Report (CDR) 1.0 Reference and Address Report Number 100358381SAT-001 Original Standard(s) Fire Test for Heat and Visible Smoke Release for Discrete Products and Their

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61754-7-2 Edition 1.0 2017-12 Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7-2: Type MPO connector family Two fibre rows INTERNATIONAL

More information

Cleaning. Instructions. Fischer FiberOptic. Connect 2 Expertise Reliability Innovation. Series

Cleaning. Instructions. Fischer FiberOptic. Connect 2 Expertise Reliability Innovation. Series Fischer FiberOptic Series Connect 2 Expertise Reliability Innovation Headquarters Fischer Connectors SA Ch. du Glapin 20 1162 Saint-Prex Switzerland Phone +41 21 800 95 95 mail@fischerconnectors.ch www.fischerconnectors.com

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

HIGH POWER FIBER OPTIC PATCHCORDS

HIGH POWER FIBER OPTIC PATCHCORDS HIGH POWER FIBER OPTIC PATCHCORDS USA PATENT #: 7431513 Features: Unique connector design minimizes thermal damage Patented connector designs for precise fiber to fiber coupling Able to withstand temperatures

More information

Fiber Optic Cable Qualification Update

Fiber Optic Cable Qualification Update Fiber Optic Cable Qualification Update EQTM 2018 Eric Rasmussen RSCC Wire and Cable LLC Eric.rasmussen@r-scc.com Terry Price Ontario Power Generation Terry.price@opg.com 1 Darlington Nuclear Generating

More information

Fibre Characterisation and FTTx New challenges

Fibre Characterisation and FTTx New challenges Fibre Characterisation and FTTx New challenges Broadband Technology Event Rotterdam, November 10th, 2009 Nicolas CARLIER France & Benelux RSM nicolas.carlier@exfo.com What is Fiber Characterisation when

More information

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software TRM 2.0 asic Software Features Generate professional acceptance reports including: OTDR traces Certification loss results/opm loss results Connector Inspection Results Create certification results and

More information

Reinforced FBG Sensors Serve Demanding Applications

Reinforced FBG Sensors Serve Demanding Applications Reinforced FBG Sensors Serve Demanding Applications Kevin Hsu, Andrei Csipkes, and Tommy Jin Technica Optical Components / 3657 Peachtree Rd, Suite 10A, Atlanta, 30319, USA, info@technicasa.com, www.technicasa.com

More information

Product Specification Qualification Test Report

Product Specification Qualification Test Report PS 88 / DMI PC SM / 6/5 DIAMOND Test & Calibration Laboratory STS 333 / SCS 11 Product Specification Qualification Test Report DMI PC SM DIAMOND SA Via dei Patrizi 5 CH-6616 LOSONE Tel. +41 91 785 45 45

More information

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES SPECIFICATION AND PERFORMANCE OF MDP CONNECTOR SERIES CIRCUIT ASSEMBLY CORP. 18 THOMAS STREET, IRVINE, CA 92618-2777 Page No. 1 of 16 CLAUSE CONTENTS PAGE 1.0 SCOPE... 3 2.0 APPLICABLE DOCUMENTS... 3 3.0

More information

HARDEST WORKING BRAND IN THE BUSINESS

HARDEST WORKING BRAND IN THE BUSINESS HARDEST WORKING BRAND IN THE BUSINESS FILL VALVES PRO45B PRO fill valves feature quieter operation, virtually no water Anti-siphon/backflow design prevents contamination of fresh water supply. Narrow profile

More information

USERS MANUAL EasySplicer

USERS MANUAL EasySplicer USERS MANUAL EasySplicer 1 Table of contents Introduction...3 Disclaimer...3 Application...3 Fusion splicer components...4 Basics...4 Order of operation...4 Connecting the splicer to power...4 Starting

More information

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date: Energy Report EDR-5391 Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49 Qualification Testing of Nuclear High Voltage Splice (NHVS) Enclosures: Report Number: Date: EDR-5391

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Product verification protocol: E06/TR04VP Applies to specification ref(s):

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3 Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Wall-Mount Pull-Out Test 4 2.2

More information

IQ/OQ Protocol Installation Qualification/ Operation Qualification

IQ/OQ Protocol Installation Qualification/ Operation Qualification IQ/OQ Protocol Installation Qualification/ Operation Qualification ZZ FreeZone Freeze Dry Systems (To be used with some FreeZone Systems manufactured prior to August, 2004- see model number chart inside)

More information

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003 Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone

More information

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 170 Report No.: E309264-D1021-1/A1/C0-UL IEC REPORT: Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and

More information

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:

More information

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components Test Report Report No. Client: Address: RES3005 Senko Advanced Components 225 Cedar Hill Street Marlboro, MA 01752 Phone: 508-481-9999 Product Tested: Q-XP MSOC 900m Test Dates: April 2010 October 2010

More information

The overview of standard of equipments used in asbestos removal Naroo Lee, Ph.D./Department of work environment

The overview of standard of equipments used in asbestos removal Naroo Lee, Ph.D./Department of work environment The overview of standard of equipments used in asbestos removal 2011.11.18 Naroo Lee, Ph.D./Department of work environment Background Asbestos is banned in Korea Social concern is safely removing Asbestos

More information

MECHANICAL INTEGRITY INSPECTIONS OF AIR COOLERS

MECHANICAL INTEGRITY INSPECTIONS OF AIR COOLERS By Joe Fazzari, P.E, Vice President of Colmac Coil Manufacturing, Inc. MECHANICAL INTEGRITY INSPECTIONS OF AIR COOLERS Owners should perform periodic mechanical integrity inspections on air coolers to

More information

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly INTERNATIONAL STANDARD ISO 22827-1 First edition 2005-10-15 Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Part 1: Laser assembly Essais de réception pour

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61754-4-1 First edition 2003-01 Fibre optic connector interfaces Part 4-1: Type SC connector family Reference number IEC 61754-4-1:2003(E) Publication numbering As from 1 January

More information

Recent and Upcoming Changes in the ANSI Z136 Series of Standards for Safe Use of Lasers

Recent and Upcoming Changes in the ANSI Z136 Series of Standards for Safe Use of Lasers Recent and Upcoming Changes in the ANSI Z136 Series of Standards for Safe Use of Lasers Ben Edwards, MS, CLSO, RRPT Duke University Medical Center edwar086@mc.duke.edu NCHPS Fall Meeting- Charlotte, NC

More information

User Manual SWIFT R5. Optical Fiber Arc Fusion Splicer. Read this service manual carefully. before running R5.

User Manual SWIFT R5. Optical Fiber Arc Fusion Splicer. Read this service manual carefully. before running R5. User Manual Optical Fiber Arc Fusion Splicer SWIFT R5 Read this service manual carefully before running R5. Table of Contents I. For Your Safety 3 II. Specifications and Components 1. Specifications 2.

More information

This is a preview - click here to buy the full publication INTERNATIONAL STANDARD. Fibre optic connector interfaces. Part 7: Type MPO connector family

This is a preview - click here to buy the full publication INTERNATIONAL STANDARD. Fibre optic connector interfaces. Part 7: Type MPO connector family INTERNATIONAL STANDARD IEC 61754-7 Edition 1.2 2000-11 Edition 1:1996 consolidated with amendments 1:1999 and 2:2000 Fibre optic connector interfaces Part 7: Type MPO connector family Interfaces de connecteurs

More information

VDE-QT-PV001:2012/01

VDE-QT-PV001:2012/01 1 VDE-QT-PV001:2012/01 VDE-QT-PV001:2012/01 Combined IEC 61215 ed.2, IEC 61730-1 ed. 1, IEC 61730-2 ed.2 plus VDE addendums 2 VDE-QT-PV001:2012/01 CONTENTS 1 Scope and object 5 2 Normative references 5

More information

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008 Intertek I 0:: o D.. W 0:: I en w I REPORT NUMBER: 3161466SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Rd. Elmendorf,

More information

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical

More information

This Unit will allow the candidate to develop the practical skills and knowledge necessary to produce a wide range of bedding plants.

This Unit will allow the candidate to develop the practical skills and knowledge necessary to produce a wide range of bedding plants. National Unit specification: general information Unit code: H1KA 11 Superclass: SE Publication date: October 2012 Source: Scottish Qualifications Authority Version: 02 Summary This Unit will allow the

More information

IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers

IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers Labconco o: 1058700 Rev. B Purpose and Scope IQ and OQ This Qualification

More information

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation.  or (800) , (603) Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Industry leading TruEvent analysis Short dead zones provide precise testing of closely spaced events Front Panel and

More information

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 6 KE 6 March 2012 GASTEC QA Approval Requirements 6 for the GASTEC QA product certificate for Plumbing fittings with ends for capillar soldering and/or thread connections Foreword These GASTEC QA Approval

More information

QATAR STANDARD QS SASO 2692/201 QS SASO 2692 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES

QATAR STANDARD QS SASO 2692/201 QS SASO 2692 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES QS SASO 2692 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES 1 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES. Date of QS Approval : Date

More information

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507 RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable Reference Guide MD-019 2014A 0507 RLH Industries, Inc. Copyright 2013 RLH Industries, Inc. All rights reserved. No part of this document may

More information

American National Standard for Safe Use of Lasers

American National Standard for Safe Use of Lasers ANSI Z136.1-2007 Revision of ANSI ZI36.1-2000 American National Standard for Safe Use of Lasers Secretariat Laser Institute of America Approved March 16, 2007 American National Standards Institute, Inc.

More information

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112

More information

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation.  or (800) , (603) Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Integrated Optical Power Meter and Visual Fault Locator Short dead zones provide testing of closely spaced events Industry

More information