A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Size: px
Start display at page:

Download "A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes."

Transcription

1 Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the heat. A boiler is used to heat the water or to produce steam. Water has a greater specific heat than air, so it carries more heat per pound. Advantages of hydronic heating systems include enhanced comfort, and lower operating costs. Steam systems may be found in residential applications but are more common in commercial applications where steam is already available for other purposes. Steam systems do not require a circulating pump and temperature losses in the piping are low, making steam ideal for heating multiple buildings from a central steam plant. A cubic foot of water weighs pounds. It boils at 212 F and freezes at 32 F. Water entering a hydronic system can contain air that is made up of nitrogen and oxygen. The oxygen in the air can cause corrosion and rusting inside the system. When water is heated, the air is driven from the water and eliminated from the system by special devices. Chemicals can be added to water to prevent minerals and oxygen within the water from forming scale and rust. Pressure drop is the difference in pressure between two points. It is caused by the friction within the pipes and within other system devices. The change in pressure drop when there is an increase or decrease in the flow in gallons per minute (gpm) can be calculated using a formula. The formula states that final gpm divided by initial gpm squared, times initial pressure drop equals the final pressure drop. Power must be available in the system to overcome the effects of pressure drop. Pump manufacturers will provide pressure drop information that can be expressed in interchangeable units. Head pressure is another measure of pressure expressed in feet of water. A column of water 1 foot high exerts a pressure of 0.43 psi. A column of water 2.31' high exerts a pressure of 1 psi. Simple formulas are available for converting between head pressure in feet and pressure in psi.

2 Static pressure is created by the weight of the water in the system. Since a 1' column of water exerts a pressure of 0.43 psi, static pressure is equal to 0.43 psi for each foot of height above the system gauge. Static pressure is lowest at the highest point in the system, and gets increasingly higher at lower points in the system. Hot-water heating systems are used to provide comfort heating. The two main types of hot-water systems are gravity hot-water systems and forced hot-water systems. Gravity heating systems do not require a circulating pump. Thermal circulation or buoyancy causes movement as hot water rises and cool water falls. Water movement in gravity systems is slow, so the system responds slowly to changing load conditions. Gravity systems are very quiet. Forced hot-water systems use a pump to circulate the heated water. This feature allows different areas in a structure (called zones) to maintain different temperatures. When a zone thermostat calls for heat, the circulating pump turns on to supply water to the zone terminal device through a zone control valve. A check valve in the return line prevents gravity circulation of water when the pump is off. Hot-water heating systems contain a variety of special components. Hot-water boilers use the same fuels that forced-air furnaces use. They include natural gas, propane, and fuel oils. Some boilers use coal or wood. The burners and the way the fuel is ignited on hot-water boilers is generally the same as found on forced-air furnaces. Venting methods are also similar. Hot-water and steam boilers share some common characteristics but have differences including their operating controls. Hot-water boilers are entirely filled with water, while steam boilers are not. Low-temperature boilers, the most commonly used, are normally designed for a 30 psi maximum working pressure with 12 to 15 psig being normal. Operating temperature is limited to a maximum of 250 F. Medium- and high-pressure boilers are built to operate at pressures above 160 psi and temperatures above 250 F. Boilers are usually made of iron or steel. The use of copper and stainless steel in the heat exchangers is gaining in popularity. Units using copper tubes are often made with cast-iron headers and sidewalls. Modern materials enable boilers to be more compact and lightweight.

3 Boilers are often installed in parallel for increased capacity and to provide redundancy. Small, gas-fired boilers can be wall-mounted with direct through-the-wall venting. Condensing boilers with efficiencies above 95% are now available. They can be vented through PVC pipe like forced-air furnaces. Modern gas-fired boilers often use the same gas valves, burners, and ignition systems found on forcedair furnaces. Sophisticated electronic controls and sensors ensure efficient operation. Cast-iron is still widely used to make boilers. They are assembled by bolting together individual cast-iron sections. The more sections used, the greater the heating capacity of the boiler. The hot-water heating system and the boiler are equipped with several controls and devices to ensure safe and correct operation of the boiler and system. A gauge that combines boiler water temperature and boiler operating pressure monitors those two important conditions. A pressure relief valve protects the boiler from excessive water temperature or steam pressure. It is designed to fully open at 30 psi. Relief valves must be installed according to the manufacturer s instructions. They should be checked periodically for proper operation. Aquastats are thermally operated switches used to control boiler water temperature or to operate other devices based on water temperature. Aquastat sensing elements can be inserted in the water directly or they can sense water temperature by being surface-mounted on the boiler or pipe. Electronic probe-type controls use an electrode placed in the water to sense water level. It uses the conductivity of the water to complete a circuit to ground. Water expands when heated. An expansion tank allows for the safe expansion of water as it is heated, preventing a dangerous condition and helping to maintain system pressure. In addition to standard expansion tanks, pressurized diaphragm expansion tanks are available. The water and the air in the tank are separated by a flexible diaphragm. Pressurized expansion tanks often come pre-charged with air, but the pressure can be field-adjusted through the charging valve to meet system design requirements. Air can be trapped in a system as it is being filled with water or released as heat drives air out of water. Air-control devices can remove the trapped air manually or automatically.

4 The circulating pump forces the hot water from the boiler, through the system, and then back to the boiler. The pump can be installed either in the supply side or return side of the system. On larger systems with high pump head, it is recommended to install the pump in the supply side. The term head pressure is used to give the capacity of a circulating pump expressed in feet of water. Pump performance curves are useful in determining pump performance under different conditions. The horizontal scale indicates pump delivery in gpm while the vertical scale shows head pressure in feet. At zero gpm, there is no delivery on the curve. At this point, the power of the pump is equal to the pressure drop opposed to it. With no pressure difference between two points, the pump will not deliver water at this point. Examination of the chart capacity curves for various impeller sizes shows that the lower the volume of water delivered by the pump in gpm, the higher the head pressure against which the pump can deliver water, and vice versa. Review the examples in paragraph and study Figure 23 for a better understanding of pump performance curves. Hot-water heating terminals transfer the heat carried by the hot water to the conditioned space. They come in several styles and shapes. A convector is a heating device that depends mainly on gravity conductive heat transfer. They are typically mounted near the floor on an outside wall. Baseboard units are often a finned-tube design and are usually installed in a continuous run along the perimeter of an outside wall. Finned-tube units are similar to baseboard units and are used for perimeter heating, often in large glassed-in areas. Radiators that are often made of cast-iron, transfer heat by radiation. They are typically found in older systems. Unit heaters consist of a finned-tube heating element and a fan contained in an enclosure. The fan moves air over the heating element, allowing heat to be transferred to the conditioned space. Unit ventilators are similar to unit heaters except they are used for both heating and cooling. Cast-iron boilers are often equipped with an internal heating coil called a tankless heater. It is used to provide domestic hot water. The tankless coil heat exchanger is immersed in the hot boiler water. Cold water passing through the tankless coil is heated by the boiler water.

5 An indirect heater is a heat exchanger installed in a hot water storage tank. Hot boiler water passes through the heat exchanger and heats the water in the tank. Both heaters require year-round boiler operation. Radiant floor heating systems consist of a continuous loop of PEX tubing installed under a floor. Warm water circulating through the tubing warms the floor. The floor then radiates heat into the room. The four general classifications of water piping systems are one-pipe, two-pipe, three-pipe, and fourpipe. One-pipe systems are used primarily for hot-water heating systems and can be either a series-loop or single-loop configuration. A series-loop one-pipe system has a continuous run of pipe from the supply to the return connection, allowing all hot water to flow through all the terminals. It is used in residential systems and may have more than one piping circuit. A variation of the series-loop one-pipe system installs special tees at each terminal that diverts some of the water from the main into each terminal. Two-pipe systems have terminals connected across separate supply and return main piping. Two-pipe, direct return systems have the supply water and return water flowing in opposite directions. Circuit-balancing valves are used with this type of system. Two-pipe, reverse-return systems have the supply water and return water flowing in the same direction through parallel pipe runs. This type of system is more easily balanced than direct-return, two-pipe systems. Zoned hydronic heating systems allow the loads in different parts of the structure to be controlled separately. Simple zoned systems use multiple zone valves and a single circulator pump. The pump is sized to accommodate total system flow at the required head of the longest or most resistant zone. More complex zoned systems use multiple circulating pumps. Each zone pump is sized to accommodate the flow rate and head pressure in its own zone piping. A dual-temperature system is a water system that circulates hot and chilled water to heat or cool with common piping and heat transfer terminals. Almost all the components used in a dual-temperature system are the same as those used in the individual heating or chilled water systems. The main differences are in the system piping and the valves or other system controls used to select heating, cooling, or both.

6 Water balancing ensures that the proper amount of hot water, chilled water, or both is delivered to the conditioned space to maintain comfort. To balance a system, water flow and pressure drop measurements are made and then valves and flowcontrol devices are adjusted. Pressures are often measured with a differential pressure gauge or manometer. The system pump must be able to provide the rate of flow (in gpm) required by the system. The rate of flow can be calculated using the formula gpm = hourly heat loss (HL) in btuh TD TD represents temperature differential, 8.33 is the weigh in pounds of a gallon of water, and 60 is the number of minutes in an hour. Once the flow rate is determined, consult a pump performance curve chart to select the circulator pump. Water flowing through pipes and fittings produces friction loss. Friction loss in any piping system should be kept to a minimum. Fittings and other components are assigned a friction loss in equivalent length of pipe. With this information, total equivalent length of pipe and fittings can be determined. Using the pump head pressure at a known flow rate, and the total equivalent length of pipe for the longest run in the system, friction loss for the system can be calculated. Friction loss per 100' of pipe can be calculated by dividing permissible head by equivalent length of pipe times 100. Review the Study Example in for a better understanding of how to calculate friction loss. The amount of head pressure added by a circulating pump at a given flow rate can be determined by measuring the pressure differential between the pumps suction and discharge ports. A formula is available that converts differential pressure measured across a pump to head. Head = (ΔP) 144 D. ΔP represents pressure differential and D represents the density of the fluid being pumped in pounds per cubic foot. The calculated total pump head pressure in feet and the pump impeller size on a pump performance curve chart can be used to determine the amount of water flow through the pump in gpm. Introduction to Hydronic Systems (Final gpm initial gpm)2 initial pressure drop = final pressure drop (10 gpm 5 gpm)2 5 psi = final pressure drop (2 gpm)2 5 psi = final pressure drop

7 4 gpm 5 psi = 20 psi The construction and operation of hot-water and steam boilers are similar, with two exceptions. The operating and safety controls used with hot-water boilers are different than those used with steam boilers. Also, hot-water boilers are entirely filled with water, while steam boilers are not. Lowtemperature boilers are the most widely used type of boiler. They are used for residential, apartment, and commercial buildings. Low-pressure hot-water boilers can be constructed to have working pressures of up to 160 psi. Normally, they are designed for a 30 psi maximum working pressure, but are frequently operated below that pressure level, with 12 to 15 psig being common. Low-pressure hot-water boilers are limited to a maximum operating temperature of 250 F. Above this temperature, even water under low pressure will begin to boil and begin the change of state to steam, creating a dangerous condition. A pressure (safety) relief valve is used to protect the boiler and the system from high pressures caused by either water thermal conditions or steam pressure conditions in the boiler. It does not operate unless an overpressure condition exists. The typical hot-water boiler is constructed for a maximum working pressure of less than 30 psi, at which point the valve is designed to be fully open. An expansion tank, also called a compression tank, is used to maintain system pressures. It allows for the safe expansion of water as it is heated. The volume of water in a piping system varies with temperature changes. When water is heated or cooled, it expands or contracts. When the system water is at maximum operating temperature, the resulting excess water volume caused by expansion is stored in the expansion tank. When the system water temperature drops and the water volume in the tank contracts, water is returned to the system. An expansion tank must be able to store the maximum volume of excess water that exists when the system is operating at maximum temperature. It must do this without exceeding the maximum system operating pressure. It also must maintain a required minimum level of system pressure when the system is cold. The circulating pump is sized to overcome the system pressure drop and to supply the necessary amount of water in gpm at the proper temperature to each terminal device. Pressure drop results from the friction caused by the system piping, fittings, boiler, terminals, and other heating components. The term head pressure is used to give the capacity of a circulating pump. It is just another way of expressing pressure drop.the maximum head of a pump is actually the maximum pressure drop against which the pump can cause water to flow. It is usually expressed in feet of water. High/low pump head are terms often used to indicate the relative magnitude of the height of a column of water that a circulating pump is moving, or must move, in a water system. Globe valves are used to adjust water or steam flow within limits that depend on system pressure variations. They are also called compression valves. Globe valves come in many configurations, but all

8 have a plug that allows gradual throttling of the water or steam. Flow through a globe valve moves in a Z-pattern that allows throttling without excessive wear on the valve seat. An angle valve is a form of globe valve, and is made with its outlet port rotated at an angle, typically 90 degrees relative to its input port. Angle valves are commonly used in various applications in place of a standard globe valve and elbow combination. Zone control valves manage the flow of water in each zone of a zoned system. They are two-position, thermostatically controlled valves. Zone control valves can be operated by heat or with an electric motor. In a heat-operated valve, a resistance wire around the valve heats the valve s bimetal element when the zone thermostat calls for heat. This causes the bimetal element to expand and slowly open the valve. When the zone thermostat is satisfied, the bimetal element cools, allowing the valve to slowly close. Electric-motor operated valves also operate to open and close the valve slowly, under control of the zone thermostat. They may contain a switch to operate the circulating pump. Slow opening and closing of zone control valves is necessary to reduce expansion noise and prevent water hammer. The time required for a typical zone control valve to open and/or close ranges from about 15 to 30 seconds. Some zone control valves have a feature that enables the valve to be opened manually in the event of a power failure. This feature is also useful when troubleshooting heating problems in a zoned system. Some zone control valves have a flow indicator dial that aids in system balancing. Many cast-iron boilers used for residential and commercial hot-water systems are equipped with an internal heater coil called a tankless heater. It is a water-to-water heat exchanger used to supply domestic hot water. The domestic hot water is contained in the coil and is quickly heated by the boiler water. In most cases, this eliminates the need for a hot-water storage tank. This type of system requires a special aquastat that maintains boiler water temperature at a certain level. The boiler runs all year long because it heats domestic water. In the direct-return system, the supply water and return water flow in opposite directions. Also, the return water from each terminal takes the shortest path back to the boiler. This means the water flowing through the terminal nearest to the boiler is the first back to the boiler, because it has the shortest run. The water flowing to the terminal farthest away from the boiler has the longest run and is the last to return. This arrangement results in an unequal length of travel for water flow through the terminals. This causes an imbalance in the system, with the result being poor heat distribution. Circuit balancing valves are normally used with direct-return systems to aid in balancing the system. Systems using zone valves generally have a single pump. In the figure, the installation of an indirect domestic water heater that often uses its own dedicated circulating pump is also shown. As individual zone thermostats call for heat, the zone valves open and allow water to flow through to the zone. To prevent the pump from dead-heading or attempting to pump with the flow fully restricted, a differential bypass valve or three-way zone valves can be used. This provides a path for some water flow when all zone valves are closed. Occasionally, this is necessary when only a very small zone is in operation as well. Otherwise, the circulating pump should operate only when one or more zone valves are in their heating position. The pump is sized to accommodate total system flow at the required head of the longest, or most resistant, zone.

9

TANKLESS WATER HEATING

TANKLESS WATER HEATING TANKLESS WATER HEATING With any gas appliance, it is essential that the gas supply system be properly sized to support the BTU load of the system. Tankless water heaters can be a great solution to provide

More information

The. Steam ONE-PIPE STEAM SYSTEMS

The. Steam ONE-PIPE STEAM SYSTEMS FULL-COLOR TRAINING GUIDE SERIES The of Steam ONE-PIPE STEAM SYSTEMS ONE-PIPE STEAM SYSTEMS PIPING AND TROUBLESHOOTING ONE-PIPE STEAM SYSTEMS ONE-PIPE STEAM SYSTEMS A. HOW ONE-PIPE SYSTEMS WORK 1. movement

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How hydronic heating systems work Advantages Disadvantages Design alternatives Baseboard convectors Residential Hydronic Heating A residential

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents Hoffman Specialty Regulators Main Steam How to Select Steam Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater Mains Vent (only) Remarks 1A X Adjustable Orifice 70A X

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall. Chapter 4 Variable-speed pumps. A variable-speed pump varies the flow rate by maintaining a constant pressure differential as zone valves open and close. A sensor measures the difference in pressure between

More information

Gas Piping Facts. Information for properly sizing gas lines for use with tankless water heaters and other gas appliances TANKLESS WATER HEATING

Gas Piping Facts. Information for properly sizing gas lines for use with tankless water heaters and other gas appliances TANKLESS WATER HEATING TANKLESS WATER HEATING Gas Piping Facts Information for properly sizing gas lines for use with tankless water heaters and other gas appliances With any gas appliance, it is essential that the gas supply

More information

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor) 1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor) 1. For year-round use, a collector tilt of degrees works best for a project located in Tampa, Florida.

More information

INFORMATION FOR TANKLESS WATER HEATERS

INFORMATION FOR TANKLESS WATER HEATERS GAS PIPING INFORMATION FOR TANKLESS WATER HEATERS Details Details regarding regarding properly properly sized sized gas lines lines for for use use with with tankless tankless water water heaters heaters

More information

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS Copyright 2011. R. Trethewey, All rights reserved. No part of this document or file may be used without permission of the author. All diagrams are conceptual

More information

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133. Main Steam How to Select Steam For Steam Vent selection information, please refer to Selection Guidelines on page 133. Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

MODERNIZATION OF HYDRONIC SYSTEMS

MODERNIZATION OF HYDRONIC SYSTEMS TECHNCAL NOTE Small Homes Council-Building Research Council, University of llinois at Urbana-Champaign MODERNZATON OF HYDRONC SYSTEMS Warren S. Harris, Professor Emeritus of Mechanical Engineering, University

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: UL 391 CAN/CSA B366.1 Unit Serial # Purchased From Company Address Name of Installer Installer Telephone # Date Installed IMPORTANT This manual must be

More information

Boiler Manual. Gas-Fired Water Boilers. Maintenance Parts. Installation Startup

Boiler Manual. Gas-Fired Water Boilers. Maintenance Parts. Installation Startup Gas-Fired Water Boilers Boiler Manual Installation Startup Maintenance Parts This manual must only be used by a qualified heating installer/service technician. BEFORE installing, read all instructions

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

Water Piping and Pumps

Water Piping and Pumps Technical Development Program DISTRIBUTION SYSTEMS Water Piping and Pumps PRESENTED BY: Michael Ho carriertdp@gmail.com 424-262-2144 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

EXTROL EXPANSION TANKS

EXTROL EXPANSION TANKS EXTROL EXPANSION TANKS For Closed Hydronic Heating & Chilled Water Systems MADE IN USA SINCE 954 AMTROL Quality Expansion Tanks Table of Contents AMTROL Quality Expansion Tanks... 2 How It Works... 2 The

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods 230520 HEAT GENERATION Cornell s Design and Construction Standards provide mandatory design constraints and acceptable or required products for all construction at Cornell University. These standards are

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

WM97+ Wall Mount Boiler

WM97+ Wall Mount Boiler WM97+ Wall Mount Boiler Questions & Answers Models 70, 110 & 155 INSTALLATION 1. Can the boiler be installed in a living area? Yes, the WM97+ is a wall mounted boiler. The sealed combustion and internal

More information

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL FloorHeat PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL Thank you for purchasing this radiant control panel assembly. Following are some important notes that will make the installation successful.

More information

"Best Practices in Modern Hydronic Heating - THE DETAILS

Best Practices in Modern Hydronic Heating - THE DETAILS "Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR TURBOMAX Instantaneous Indirect Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR Your TURBOMAX Instantaneous Indirect Water Heater has been carefully assembled and factory

More information

- Data Brochure Boiler Control 274

- Data Brochure Boiler Control 274 - Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When

More information

BOILERS. Air Vent. Supply. Drain Valve

BOILERS. Air Vent. Supply. Drain Valve BOILERS AND WATER HEATERS Boilers BOILERS Vent (Chimney) Return Pressure Releif Valve Aquastat Air Vent Pressure Reducing Valve Water Feed Valve Flow Control Valve Supply Pressure / Temp Gauge Expansion

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

Get The Edge Over The Competition with The Summit

Get The Edge Over The Competition with The Summit Gas-Fired Hydronic Boilers Condensing and Modulating for Low NOx and High Efficiency Get The Edge Over The Competition with The Summit Solve installation problems and significantly reduce running costs

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

AIR CONDITIONING. Carrier Corporation 2002 Cat. No AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

Applications and Piping Strategies for Condensing Boilers - Introduction

Applications and Piping Strategies for Condensing Boilers - Introduction Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control

More information

Fundamentals of Hydronic Design

Fundamentals of Hydronic Design Radiant Based HVAC Systems www.healthyheating.com Dynamic Pressure www.healthyheating.com This educational material is copy written by Robert Bean, R.E.T., All Rights Reserved. If you wish to use this

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

SECTION WATER HEATERS

SECTION WATER HEATERS SECTION 15457 WATER HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete hot water generating system with necessary accessories as indicated on Construction Documents, as specified, and

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs CodeNotes is provided courtesy of the ICC PMG Official Membership Council CodeNotes Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions Introduction Solar water heating

More information

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 423 - Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

TANKLESS PRODUCT GUIDE

TANKLESS PRODUCT GUIDE TANKLESS PRODUCT GUIDE SOLID. STATE. When it comes to building durability into a product, nobody does it like State. In fact, we've tested our water heaters in some of the most hostile environments and

More information

Wood Boiler Plumbing Schematics

Wood Boiler Plumbing Schematics Wood Boiler Plumbing Schematics Solo Plus Froling FHG Solo Innova Excel Multi-Fuel 2 TABLE OF CONTENTS Section Page 1.0 Introduction..4 2.0 Plumbing Diagrams....5 2.1 Plumbing Example-Solo/Excel 1........5

More information

Glossary. Carbon Dioxide (CO 2

Glossary. Carbon Dioxide (CO 2 Glossary AFUE (Annualized Fuel Utilization Efficiency): A measure of the efficiency of the heating unit (burner and boiler/ furnace) including standby losses during the off-cycles, given on an annual basis.

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

Boiler Manual. Gas-fired water boilers Series 3. Installation Startup. Maintenance Parts. Featuring. Flexibility

Boiler Manual. Gas-fired water boilers Series 3. Installation Startup. Maintenance Parts. Featuring. Flexibility Gas-fired water boilers Series 3 Featuring Flexibility Boiler Manual Installation Startup Maintenance Parts This manual must only be used by a qualified heating installer/service technician. Read all instructions,

More information

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs Lesson 1 - Basic Heat Pump Theory (Part 1) Describe the basic operation of a heat pump. Explain the function of various heat pump controls. Interpret the wiring diagrams and performance data provided by

More information

Raypak Residential Products

Raypak Residential Products Raypak Residential Products Raypak s Residential Boiler Product Family Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned copper

More information

The. Steam TWO-PIPE STEAM & PUMPED RETURN

The. Steam TWO-PIPE STEAM & PUMPED RETURN FULL-COLOR TRAINING GUIDE SERIES The of Steam TWO-PIPE STEAM & PUMPED RETURN The Color of Steam The Color of Steam A. PUMPED RETURN SYSTEMS 1. When Is a Pump Needed? 2. Pumped Return Systems 3. Boiler

More information

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE A. O. Smith www.hotwater.com A. O. Smith Tankless Advantage ENDLESS HOT WATER * Heating water only as it s being used means you will never run out of

More information

Pumps SELECTION OF A PUMP

Pumps SELECTION OF A PUMP Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water

More information

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI Vent-Rite BULLETIN VCRV AUGUST 0 GUARDIAN Plus Cast Iron And Steel Receivers Simplex, Duplex, Triplex And Quadruplex Units Pump Capacities To 0 GPM Discharge Pressure To 7 PSI 87 Dewey Avenue Benton Harbor,

More information

Columbia Boiler Company

Columbia Boiler Company EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net

More information

Boiler Manual. Gas-fired water boilers. Featuring. Flexibility

Boiler Manual. Gas-fired water boilers. Featuring. Flexibility Gas-fired water boilers Featuring Flexibility Boiler Manual This manual must only be used by a qualified heating installer/service technician. Read all instructions, including this manual and all other

More information

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762 AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation 4151 112 th Terrace North Clearwater, Florida 33762 COMMERCIAL REFRIGERANT DESUPERHEATER WASTE HEAT RECOVERY INSTALLATION/OPERATION/MAINTENANCE

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

COMMON WATERSIDE ECONOMIZER APPLICATIONS: APPLICATION MANUAL WATERSIDE ECONOMIZER TABLE OF CONTENTS Safety Approvals...1 Common Waterside Economizer Applications...1 Sequence of Operation (Single)...1 Cooling Mode...2 Heating Mode...2 Sequence

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

TEMPERATURE CONTROLLERS

TEMPERATURE CONTROLLERS Instruction Manual: H1 T-12 Thermostat PILOT GUARD INTRODUCTION: SCOPE: This instruction manual includes installation, operation, and parts information for the Kimray Thermostat and Pilot Guard. Refer

More information

DISTRIBUTION SYSTEMS. Water Piping and Pumps

DISTRIBUTION SYSTEMS. Water Piping and Pumps DISTRIBUTION SYSTEMS Water Piping and Pumps Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are targeted

More information

www.americanwaterheater.com Energy-efficient, plentiful, and endless supply of hot water. Compact size and wall-mounted to free up valuable floor space. SAVE ENERGY. SAVE SPACE. PAGE [ 2 ] American Water

More information

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

Hydronic Product & Application Catalog

Hydronic Product & Application Catalog Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose

More information

The electrical wattage needed by the circulator is:

The electrical wattage needed by the circulator is: The electrical wattage needed by the circulator is: w e = 0.4344 f P n w/w A current-generation wet-rotor circulator has a maximum wire-towater efficiency in the range of 25 percent. If we put the data

More information

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual Peerless Indirect-Fired Partner Water Heater Installation, Operation & Maintenance Manual Product Selection 1. The following guidelines apply to residential systems only. For commercial or institutional

More information

DISTRIBUTION SYSTEMS. Water Piping and Pumps

DISTRIBUTION SYSTEMS. Water Piping and Pumps DISTRIBUTION SYSTEMS Water Piping and Pumps Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are targeted

More information

Well Tanks and Expansion Tanks

Well Tanks and Expansion Tanks Well Tanks and Expansion Tanks Water Worker well tanks are specifically engineered to provide a buffer of clean, fresh, pressurized water that reduces pump cycling, saves energy and improves system performance.

More information

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle Steam Trap Presentation for IDEA Distribution Workshop Presenter: Joe Radle Proper Piping when Reducing Pipe Size Concentric reducer Eccentric reducer Correct Wrong Typical Steam Main Drip Station D Size

More information

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757 Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI AERCO MODULEX BOILERS MLX-1060 MLX-909 MLX-757 MLX-606 MLX-454 MLX-303 Seasonal Efficiency Longevity Part-Load Efficiency

More information

Hydraulic Separation Moving Beyond Priamry / Secondary Piping...

Hydraulic Separation Moving Beyond Priamry / Secondary Piping... Hydraulic Separation Moving Beyond Priamry / Secondary Piping... load! #1 load! #2 load! #3 primary! circulator presented by: John Siegenthaler, P.E. Appropriate Designs Holland Patent, NY www.hydronicpros.com

More information

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS 6.1 Types of Heating Systems 6.2 Heating Energy Sources 6.3 Furnaces and Air Heaters 6.4 Boilers 6.5 District Heating 6.6 Selection of Medium- Steam

More information

Use this Construction/HVAC Glossary to answer the questions below.

Use this Construction/HVAC Glossary to answer the questions below. www.garyklinka.com Page 1 of 21 Instructions: 1. Print these pages. 2. Circle the correct answers and transfer to the answer sheet on the second last page. 3. Page down to the last page for the verification

More information

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning Blueprint HVAC - Heating, Ventilation and Air Conditioning Test Code: 0144 / Version: 02 Specific Competencies and Skills Tested in this Assessment: Electricity Demonstrate understanding of basic AC/DC

More information

BOILER APPLICATION GUIDE for:

BOILER APPLICATION GUIDE for: T MFC Series Boiler Application Guide GF-148-B TECHNICAL APPLICATION GUIDE BOILER APPLICATION GUIDE for: Piping and Controls, Water Quality, and Single/Multi Installations Applies to MFC Series Models:

More information

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control. Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow

More information

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13 COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY Convectors STEAM AND HOT WATER RADIATION CC-13 Sterling Convectors are engineered for both forced hot water and two-pipe steam heating system installation

More information

PACKAGED AIR COOLED Product Data Catalog

PACKAGED AIR COOLED Product Data Catalog PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES

More information

6 PIPING ARRANGEMENTS

6 PIPING ARRANGEMENTS 6 PIPING ARRANGEMENTS The design of a panel radiator based heating system involves selection of a piping system, pipe sizes, overall design temperature drop, required flow rates and desired type of system

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

Revitalize Building Mechanical Systems (4619)

Revitalize Building Mechanical Systems (4619) SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B BW1, BW2 & BW3 Gas-Fired Water Boilers Series B Product Data MODEL BW1, BW2 Series B MODEL BW3 Series B MODELS BW1, BW2, and BW3 Models BW1 and BW2 Gas-Fired Hot Water Boilers provide fast heat quietly

More information

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers NOW WITH AUTO SET POINT AND OUTDOOR RESET INCLUDED! THE COMPACT MINI-THERM FOR SUPERB HOME HEATING COMFORT LAARS MINI-THERM gas-fired residential

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.

More information

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR 5:1 FIRING RATE MODULATION LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 96% AFUE

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Open Cooling Towers: a treatment system utilizing chemicals and biocides that contain no heavy metals and are non-carconigenic to prevent corrosion,

More information

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return Single Zone System One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return Multi Zone System Used in small to medium sized buildings

More information

Plumber Level 3 Rev. May 2011

Plumber Level 3 Rev. May 2011 Level 3 C1 Commercial Sanitary Drainage Systems Duration: 16 hours 10 hours 6 hours This unit of instruction is designed to provide the Plumber apprentice with the basic knowledge and understanding of

More information

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS Inverted Float & Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS ABOUT US In 1916, the company, then known as the Sterling Engineering Company, began designing and manufacturing valves, traps, strainers

More information

Solar water heating system

Solar water heating system Solar water heating system Perhaps the most popular application of solar systems is for domestic water heating. The popularity of these systems is based on the fact that relatively simple systems are involved

More information

Draft Controls. When to use a Draft Control

Draft Controls. When to use a Draft Control Draft s For proper operation and efficient fuel consumption in oil, gas and/or coal-fired heating appliances, draft must remain constant. When it is, combustion is more complete, fuels are utilized efficiently,

More information