Schaefer HotZone HZE & HZS Series Electric Spot Heater

Size: px
Start display at page:

Download "Schaefer HotZone HZE & HZS Series Electric Spot Heater"

Transcription

1 Schaefer HotZone HZE & HZS Series Electric Spot Heater High Output Infrared Heater INSTALLATION & OPERATION INSTRUCTIONS ** HOTZONE HEATERS MUST BE INSTALLED BY A LICENSED ELECTRICIAN. ** HZE Series HZS Series always install heater with the junction box on the low side sales@schaeferfan.com

2 Table of Contents INTRODUCTION...3 OPERATINg NOTES CLEARANCE TO COMBUSTIBLES...6 HZE SERIES MOUNTINg OPTIONS...7 MOUNTINg INSTRUCTIONS...8 ELECTRICAL CONNECTION...9 ANgLE ADJUSTMENT...9 ELEMENT REPLACEMENT HZS SERIES MOUNTINg OPTIONS...11 ELECTRICAL CONNECTION...11 ANgLE ADJUSTMENT...12 ELEMENT REPLACEMENT...12 MAINTENANCE AND TROUBLESHOOTINg...13 REPLACEMENT ELEMENTS...14 CALCULATINg CURRENT REQUIREMENT...15 HZE & HZS Series Control Options A number of control options are available that can enhance the performance and enjoyment of your HotZone heater. Contact your local licensed electrician for more information. ON/Off SwITCHES STAgINg Control single or multiple heaters using direct connections or relays. Switches that turn on parts of the heater individually or parts of the service to multiple heaters for times of lower heat requirements. DIMMERS Continuous control or "dimming" of heater from 100% down to 0%. THERMOSTATS TIMERS Used to automatically turn heater on or off at specific temperatures. Used to automatically turn heater on or off at specific times. ETL Label 2

3 Introduction Congratulations on purchasing a Schaefer HotZone electric infrared Heater. Unlike forced air heaters, HotZone heaters warm people and objects, but not the air, with infrared radiation. your new heater has no moving parts, and should give you many years of maintenance-free comfort. HotZone heaters have the patented, lobster eye inspired, compound reflective irlens that focuses and directs the infrared energy into a beam (or a spot). these lenses are lightweight aluminum grids that look like a four-walled honeycomb structure and are capable of focusing the infrared energy without overheating. because HotZone heaters focus and direct the infrared energy into a beam: HotZone heaters can be installed out of the way of people and equipment. the radiant intensity is much less sensitive to distance from the heater (your head doesn't cook while your feet freeze). they deliver up to five times as much infrared energy to the spot, compared to similar powered, unfocused high intensity infrared heaters. they will raise the surface temperature of a 14 square foot area by 15 with a single 1500 watt heater mounted eight feet above it. they will raise the surface temperature of a 25 square foot area by 20 with a single 3000 watt heater mounted ten feet above it. Plan your installation by identifying the area you want heated and how much temperature increase you need. imagine the heater as a kind of floodlight and place it so as to cover your target area with enough heat. the temperature increase resulting from the heater "shining" on a target depends on the power of the heater, the distance from the heater to the target and how close the target is to the center of the spot. do not allow the heater to be aimed at a wall or any other combustible material. the heater unit with fixed mount is etl certified to Ul 2021 (Fixed and location dedicated electric room Heaters) for installation both indoors and outdoors. warning the safety of this product can only be guaranteed if these instructions are followed. Please keep them for future reference. Always disconnect the heater from the main electrical supply during installation and/or replacement of the heater element. Infrared energy heats people and objects when it is absorbed. Flammable objects placed too close to the heater lens could catch fire. CAUTION ** HotZone HeAterS must be installed by A licensed electrician ** 3

4 HZE & HZS Series Operating Notes * IMPORTANT INSTRUCTIONS * when using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. read all instructions before assembling, installing and using this heater. 2. this heater is hot when in use. to avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, paper, clothes and curtains at least 48" (1500 watt) / 66" (3000 watt) / 96" (5000 watt) from the front of the heater and keep them away from the sides and rear. Do not install closer than the minimum clearances to any surface. 3. extreme caution is necessary when any heater is used by or near children or persons that may not have reasonable judgement around appliances. the heater should not be left unattended while operating. 4. if heater has a cord and plug, always unplug when not in use. 5. do not operate any heater with a damaged cord or plug (if applicable) or after the heater malfunctions, or has been dropped or damaged in any manner. return heater to dealer for examination, electrical or mechanical adjustment, or repair. 6. this heater is not intended for use in bathrooms, laundry areas and similar indoor locations. never locate heater where it may fall into a bathrub or other water container. 7. if heater has a cord, do not run cord under carpeting. do not cover cord with throw rugs, runners or similar coverings. Arrange cord away from traffic area and where it will not be tripped over. 8. to disconnect heater, turn control off (if provided), then remove plug from outlet (if applicable). 9. if heater has a cord and plug, connect to properly grounded outlet only. the heater should always be connected to a grounded circuit. if a GFCi socket is not available, GFCi adapters can be purchased locally. Heater must be installed according to nec and all local electrical codes. be sure the electrical supply is adequate for the heater (voltage/amps/phase) while allowing for line losses. Use supply wires suitable for 90 C. 10. do not insert or allow foreign objects to enter the heater or block any ventilation openings as this may cause an electric shock or fire, or damage the heater. do not cover or obstruct the heater while operating. 11. A heater has hot and/or arcing and/or sparking parts inside. do not use it in areas where gasoline, paint, flammable liquids or highly combustible dusts are used or stored. 12. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, elecric shock, or injury to persons. 13. if heater has a cord and plug, avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if an extension cord must be used, please contact your local licensed electrician for a safe recommendation based on heater voltage, wattage and cord length. Heaters rated 120 volts will require appropriate gauge three-wire cord with grounding type plug and cord connector. 14. if the unit is installed in proximity of tents or awnings, make sure that recommended installation heights and clearances are respected, and that the heater is not in direct contact with the tent or awning material. 15. Allow for user angle and directional adjustment, if possible, as heating requirements change. the optimal mounting angle is between directly down and 45. Comfort is best obtained with the heater off to one side and angled at 35. install heaters so that items in the infrared beam do not overheat. 4

5 HZE & HZS Series Operating Notes cont'd 16. burned-out elements cannot be repaired and must be replaced. the element can be replaced by the user; please follow the instructions provided. Always disconnect the heater from the main electrical supply during installation and/or replacement of the heater element. 17. to prevent a possible fire and to increase the life of the heater, always install HZS Series heaters with the internal junction box on the low side. Failure to mount the heater with the junction box on the low side may void the warranty. 18. After the heater is installed and power is turned on, the element should begin glowing within 20 to 30 seconds and glow a uniform red-orange color within two to three minutes. If it begins glowing more quickly or glows very brightly, turn the heater off immediately and re-check the supply voltage. 19. the heater will smell very hot for the first few minutes of operation, then will stop emitting an odor. 20. the HotZone heating element operates at approximately 1800 F. the element is resistant to thermal and mechanical shock, and is appropriate for use in both wet and dry locations only if permanently mounted on a junction box. 21. the element has an expected life of 2000 hours. When an element burns out, it cannot be repaired and must be replaced. For replacement, have your heater model number available and call your Schaefer HotZone dealer to order the correct element. 22. if the position of the heater needs to be adjusted after it is attached to the mount, be very careful. DO NOT GRAB THE HEATER HEAD AND TWIST! the heater can be adjusted up and down, but it cannot be adjusted from side to side. * SAVE THESE INSTRUCTIONS * CAUTION ** do not USe this HeAter For APPliCAtionS For WHiCH it is not intended ** HotZone heaters are intended for heating people or objects from a distance in excess of the minimum distance to combustibles. Use of the heater for applications such as paint drying or equipment heating from a short distance where infrared energy will reflect back toward the heater will overheat the element, causing early element failure and negating the warranty. CAUTION ** do not USe this HeAter AS A PortAble HeAter ** HotZone heaters are designed, listed and approved as fixed and location-dedicated heaters. If the heater is used as a portable heater there is a great risk of fire and/or heater damage if the heater is placed too close to combustibles or if the heater tips over. 5

6 HZE & HZS Series Clearance to Combustibles NOTES mount the heater at or above the MINIMUM MOUNTINg HEIgHT. make sure the MINIMUM DISTANCE TO COMBUSTIBLES is maintained around and below the heater. the bulk of the heat radiates from the lens of the heater and care must be taken to keep combustibles out of the COMBUSTIBLE AVOIDANCE ZONE of the beam. At minimum distance to combustibles heaters will not raise the temperature of a highly absorptive surface more than 90 F. the minimum distances around the heater are not as critical as the combustible avoidance zone below the heater. do not allow the heater to be aimed at a wall or any other combustible material. HZX15 HZX30 HZX50 Mounting Angle MINIMUM MOUNTINg HEIgHT 72" 72" 72" 72" 96" 96" MINIMUM DISTANCE TO COMBUSTIBLES (around heater) Above 6" 6" 9" 9" 12" 12" Back 9" 9" 18" 18" 30" 30" front 9" 30" 18" 41" 30" 59" Side 9" 9" 18" 18" 30" 30" Below (in beam) 48" 48" 66" 66" 96" 96" DIAMETER Of COMBUSTIBLE AVOIDANCE ZONE (below heater) Distance from lens 12" 26" 32" 38" 24" 36" 42" 48" 36" 46" 52" 58" 48" 56" 62" 68" 60" 72" 78" 72" 82" 88" 84" 98" 96" 108" COMBUSTIBLE AVOIDANCE ZONE CAUTION ** DO NOT LEAVE HEATER OPERATING UNATTENDED ** ** DO NOT INSTALL THIS HEATER ABOVE FLAMMABLE MATERIAL ** the elements in HotZone heaters will eventually fail, much like a light bulb will eventually fail. When a heater element fails, extremely hot material may be ejected from the heater and this material can damage or ignite materials under the heater. to avoid these dangers, do not install heaters directly above flammable materials or materials that can be damaged by hot materials, do not leave the heater operating unattended, and replace elements before they fail. 6

7 there are three standard mounting configurations for HZe Series heaters and one that must be purchased separately. HZE Series Mounting Options the angle adjustment assembly on the back of the heater is designed for mounting flexibility, but the correct configuration should be determined before the heater is attached to the universal fixed mount. Figure 1 1 Heaters to be mounted on the wall should have the angle adjustment assembly attached below the center of the heater (standard configuration - Figure 1). 2 Heaters to be mounted on the ceiling and aimed sideways should have the angle adjustment assembly attached above the center of the heater (standard configuration, heater mounted "upside down" - Figure 2). 3 Heaters to be mounted on the ceiling and aimed down should have the angle adjustment assembly attached in the center of the heater (assembly needs to be reversed - Figure 3 - heater cannot adjust far enough without reversing). Figure 2 Figure 3 REVERSINg THE ANgLE ADJUSTMENT ASSEMBLY for CEILINg MOUNT Save all hardware for re-use! 1. remove the two cap screws from the back of the heater, which are holding the louvered element tray in place. 2. Slide the element tray out of the heater. Pull the high temperature element wires through the hole in the angle adjustment assembly to free the element remove the two allen screws that attach one end of the curved mounting plate to the heater. 4. remove the two allen screws that secure the other end of the curved mounting plate, internal ring clamps and angle adjustment assembly to the heater. detach the ground wire as well. 5. reverse the orientation of the curved mounting plate and angle adjustment assembly. 6. re-attach the curved mounting plate, ring clamps and angle adjustment assembly to the heater. re-attach the ground wire a 6b 7 7. Feed the high temperature element wires through the angle adjustment assembly and slide the element tray back into the heater. Fasten the element tray to the heater. fixed wall MOUNT An optional fixed wall mount is available from your Schaefer HotZone dealer. this mount consists of a three-position bracket that attaches to a post or wall, and the heater plugs into an outlet located nearby. Additional assembly instructions are provided with the mount. 7

8 HZE Series Mounting Instructions NOTE: Does NOT include hardware (screws) for attaching the universal mounting plate to the junction box. Tools required: UNIVERSAL fixed MOUNT #2 Phillips head screwdriver tools required to attach universal mounting plate to junction box 1. turn off supply voltage to the junction box at the panel. 2. thread the supply wires through the hole in the center of the universal mounting plate. orient the universal mounting plate so the four cover plate mounting holes are on the sides, not the top and bottom. Attach the universal mounting plate to the junction box with appropriate user-supplied screws. For additional support, secure the mounting plate to the ceiling or wall using appropriate screws (not provided) at the corners of the universal mounting plate. NOTE: If the heater is to hang from the ceiling, refer to the Angle Adjustment instructions to reverse the angle adjustment assembly before continuing. 3. thread the lead wires from the heater through the appropriate tube (provided - choose the 8" tube for ceiling mount; 4" tube for wall mount) and then through the stub in the cover plate. 4. Secure the tube to the heater stub with a trilobal screw (provided). Secure the tube to the cover plate stub with the remaining trilobal screw. 5. recruit an assistant to hold the heater. you may need to cut the clips off the ends of the lead wires and strip them to accommodate wire nuts. Use wire nuts to connect the lead wires from the heater to the power supply. be sure the lead wire with the green label is connected to the green (ground) power supply wire. 6. lift the heater up to the universal mounting plate and carefully coil the wires and connections into the junction box. Secure the cover plate to it with the four screws (provided). Be sure all screws are secure and sufficient to hold the weight of the heater. If any mounting hardware is loose or insufficient the heater may fall. 7. turn on the power supply and test operation. this mount attaches the heater to a junction box in the ceiling or wall. to mount directly to a wall (not to a junction box) optional accessories are required. Choose a location that meets or exceeds the minimum distance to combustibles on all sides and in front of the heater. mount the heater at least 72" above the ground. refer to CLEARANCE TO COMBUSTIBLES. 8

9 HZE Series Electrical Connection All wiring must be in accordance with the national and local electrical Codes. the heater housing must be properly grounded. install circuit protection for each heater or bank of heaters as required. ** Always be sure the supply voltage is turned off to the junction box before starting installation. ** 1. Connect the service to the heater with properly sized conductors and wire nuts rated for 90 C. 2. Use waterproof conduit or flex if installed outdoors or in wet areas as needed. 3. Connect service to the high temp wires according to the appropriate wiring schematic on page Supply heater control equipment as required to turn heaters on and off, to allow each heater to be staged for low/high voltage operation, to be dimmed, or to be controlled by sensors or timers. 5. be sure you are supplying the correct voltage to the heater, allowing for line losses. the heater's voltage requirements are marked on its shipping box and on its etl certification label. Too much voltage will burn the heater element out immediately. Too little voltage or inadequate current capacity will cause the heater element to run cool, and can cause the supply circuit to overheat dangerously. the angle adjustment assembly has approximately 40 degrees of motion, which allows the heater to be aimed at the desired target. the angle of the heater can be adjusted up and down only. be sure to loosen the allen screws before moving the heater, and then tighten them just enough to hold the unit in place. Overtightening can bend the frame and damage the unit. HZE Series Angle Adjustment HZE Series Element Replacement HZE SERIES ELEMENT REPLACEMENT Always disconnect the heater from the main electrical supply during installation and/or replacement of the heater element. Figure 1 - High-temp lead wires exit mounting stub. 1. turn off the power supply at the panel. 2. Carefully remove the heater from the mount and disconnect the power supply wires. the original white high-temperature lead wires should be coming out through the mounting stub. (Figure 1) ** Be sure to save all hardware for re-use! ** 3. Place the heater on a level, flat surface. be careful not to bend the lens (lay the heater on a soft or padded surface, such as a folded towel or bubble wrap). (Continued on next page) 9

10 HZE Series Element Replacement cont'd 4. remove the two allen screws that hold the element frame in place. (Figure 2) Figure 2 - Two allen screws hold element frame in housing. 5. Carefully slide the element frame out to one side. notice the high temp wires are being pulled through the mounting stub; feed them out as they are pulled by the frame. (Figure 1 and Figure 3) 6. lay the element frame as flat as possible next to the heater (still attached by the lead wires). (Figure 4) 7. disconnect the lead wires from the ring terminals on the used element. Do not lose the hardware! (Figure 5) Figure 3 - Element in frame slides in/out of housing. 8. loosen the four screws that hold the element in the frame. remove the used element. Be careful not to knock off, puncture or lose the four insulating pads on the element wrap. (Figure 4) 9. remove the single screw that holds the element wrap in place. remove the old element from the wrap and replace with same model of new element. be sure to replace the screw. 10. lay the new element into the frame. Center it and then tighten the four screws to hold it in place. Be careful not to knock off, puncture or lose the four insulating pads on the element wrap. NOTE: the four pads MUST be put back in this step! Figure 4 - Element in frame with lead wires connected. 11. Attach the high-temperature lead wires using the hardware that was removed from the used element. Follow the appropriate wiring schematic on page Carefully slide the element frame back into the heater. the lead wires must be carefully pulled back through the mounting stub as the element is slid into place (leaving them loose in the heater housing can cause them to overheat). (Figure 1) 13. replace the two allen screws that hold the element frame in place. (Figure 2) four screws hold element Figure 5 - Lead wires disconnected from element. 14. Using a resistance meter, check for element continuity and shorts to ground. the resistance from a hot lead to ground should be several mega-ohms, and the resistance between hot leads should be between 10 and 50 ohms, depending on the element. 15. re-attach the heater to the mount using the hardware removed in Step 2. Connect the heater to electrical supply and test for operation. 10

11 HZS Series Mounting Options HZS SERIES MOUNTINg OPTIONS HZS Series heaters come complete with an adjustable universal mounting tab that can be used in many ways. it may have to be removed and rotated for some installations. it has been designed to fit a variety of electrical junction boxes. A B C Universal mounting tab - standard attachment to post or wall with remote electrical connection. Hang the heater directly from an electrical junction box with emt connected with compression fittings. Attach the emt to the bracket securely. if feeding wire in wet locations, allow room at the end of the pipe for the flex junction. A 20 bend in the last 8-12" of the emt gives a "pendant" style look to the installation. the junction box must be on the bottom side. For horizontal mounting to a flat surface, a single bolt placed in one of the middle holes allows for left/right adjustment. A refer to CLEARANCE TO COMBUSTIBLES for more information. B warning To prevent a possible fire and to increase the life of the heater, always install heater with the junction box on the low side. Failure to mount the heater with the junction box on the low side may void the warranty. NOTE: the in-ceiling bezel mount is no longer recommended because it positions the junction box beside, not below, the heater. C HZS Series Electrical Connection All wiring must be in accordance with the national and local electrical Codes. the heater housing must be properly grounded. install circuit protection for each heater or bank of heaters as required. ** Always be sure the supply voltage is turned off to the junction box before starting installation. ** 1. Connect the service to the heater with properly sized wires, connectors and wire nuts rated for 90 C (194 F). 2. Use waterproof conduit or flex if installed outdoors or in wet areas as needed. 3. Attach grounding wire to the green screw in the bottom of the junction box. 4. Connect service to the high temp wires according to the appropriate wiring schematic on page Junction box has 17.3 cubic inches (112 cubic centimeters) of wiring space and a 1/2" threaded hole. 6. Supply heater control equipment as required to turn heaters on and off, to allow each heater to be staged for low/high voltage operation, to be dimmed, or to be controlled by sensors or timers. 7. be sure you are supplying the correct voltage to the heater, allowing for line losses. the heater's voltage requirements are marked on its shipping box and on its etl certification label. Too much voltage will burn the heater element out immediately. Too little voltage or inadequate current capacity will cause the heater element to run cool, and can cause the supply circuit to overheat dangerously. 11

12 HZS Series Angle Adjustment the angle of the heater can be adjusted up and down. there are two adjustment screws, one on either side of the mounting bracket. be sure to loosen them before moving the heater, and then tighten them evenly to hold it at the desired angle. Outer Side of Bracket Inner Side of Bracket HZS Series Element Replacement HZS SERIES ELEMENT REPLACEMENT Lid Always disconnect the heater from the main electrical supply during installation and/or replacement of the heater element. Support Bracket (2x) 1. turn off the supply power at the panel. 2. disconnect and dismount the heater. 3. remove the lid. Enclosure Head Wrap Ring Terminals Element 4. remove the nut and bolt from the ring terminals on the back of the element. 5. remove the screws that fasten support brackets to enclosure (if necessary). 6. Pull the head wrap, element and support brackets out of the enclosure just enough to expose the screws on the side of the head wrap. Wire Hold-down 7. remove the support brackets from the head wrap and remove the top two screws on the head wrap allowing the old element to be pushed out and replaced by the new element. 8. Push the new element tight to the face of the head wrap and replace the top two screws. Electrical Box Cover 9. Set the head wrap with the support brackets into the enclosure and pull the excess wire back through the electrical box and secure with clamp. Position the support brackets on each side of enclosure and replace and tighten the two screws. 10. re-install the nut and bolt into ring terminals. 11. Place lid onto enclosure and tighten screws. 12. Place on the electrical box cover and tighten screws. 13. re-connect and re-mount the unit. 14. test unit. 12

13 HZE & HZS Series Maintenance and Troubleshooting MAINTENANCE the heater body can be washed with gentle detergent and a soft wash cloth. Do not use a pressure washer. With an air hose regulated to 30 psi, blow off any dust and dirt from in front of the heater that has accumulated on the reflective surfaces of the heater and reflective lens. A vacuum cleaner can be used as well. Accumulated dirt will degrade performance. blow off or vacuum any accumulated dirt on the vent holes of the heater and make sure they are not bent such that the vent area is reduced. When not installed or in use, store the heater in a dry, dust-free place and be sure the lens assembly is protected from any possible damage. the heater lens is manufactured from thin aluminum and is easily bent and damaged. Heater performance deteriorates when the lens is bent or damaged. in most cases the lens can be bent back into shape by hand or with pliers. if the heater is turned on when wet it may steam and sizzle a bit but this will subside as it dries. replacement high-temperature lead wires must be capable of handling 1000º F and have stainless steel terminals. TO CHANgE THE COLOR Of THE HEATER the outer housing of the heater can be spray painted with high-temp metal paint. DO NOT paint the bare aluminum lens or inside surfaces. (the bare aluminum reflects 100% of the infrared heat; paint absorbs infrared and will cause the unit to overheat. This will void the warranty.) TROUBLESHOOTINg At full power and after two to three minutes of warm-up time, the heater element should glow a warm orange color, similar to the color of coals in a hot fire. If the element does not warm up at all: is the service power on at the circuit breaker? is there a switch or dimmer in the circuit? is the switch on? is the heater connected to the appropriate power source (plug or junction box)? is the element in working condition? burned out elements normally have visible burn marks on the face of the element. if there is no evidence of damage, and you still suspect the element, turn off the power at the circuit breaker, disconnect the service power and check element resistance. it should be between 10 and 50 ohms, depending on the element. Are the high temperature leads connected to the element? turn off the power at the circuit breaker. remove the element from the heater housing and check the connections at the back of the element. If the element barely glows: is the heater on a dimmer? is the dimmer turned full on and operating correctly? is the heater connected to the correct line voltage (under load condition) for its element type? 120V models must be plugged into an outlet that provides 120V. if the outlet provides less than 120V the element will not operate correctly. is the element wired correctly, and are all connections intact? note: three phase devices where one leg is disconnected will operate with reduced output. If the element glows a bright orange-white and heats up very quickly: The heater is receiving too much power and will burn out very quickly if it is not turned off. is the heater wired correctly for its element type? is the element damaged? A short circuit between adjacent coils will cause some coils to go dark and some coils to overheat. damaged elements cannot be repaired and must be replaced. 13

14 HZE & HZS Series Replacement Elements Power No. of No. of Voltage Alt. Voltage Element Heater (w) Stages wires Schem. (V) Schem. (V) 7501 HZRE15120C HZX A HZRE15208C HZX A* HZRE15240C HZX A* HZRE15277C HZX A HZRE30120/240C HZX30120/ B 120 B' HZRE30208C HZX B* 208 HZRE30208AC HZX30208A A* HZRE30208YC HZX30208Y C 208 (1) HZRE30208DC HZX30208D D HZRE30240/480C HZX30240/ B* 240 B' HZRE30277C HZX A HZRE30480C HZX A* HZRE50120C HZX C HZRE50208SC HZX B* HZRE50208YC HZX50208Y C 208 (1) HZRE50208DC HZX50208D D HZRE50240/480C HZX50240/ B* 240 B' HZRE50277C HZX B HZRE50346C HZX A HZRE50480YC HZX50480Y C 480 (2) HZRE50600C HZX A* 600 NOTES: All heaters have a ground wire attached to the heater shell (not the element). Alternate connections for dual service elements are under "Alternate Schematic". Schematics with an asterisk (A*, b*) connect to a common hot wire (H), not a neutral wire (n). Schematics with an apostrophe (b') require the neutral wire (n) to be capped. Heater elements and wiring schematics that allow high/low staging are shaded. (1) Voltage between hot and neutral is 120V. (2) Voltage between hot and neutral is 277V. 14

15 HZE & HZS Series Calculating Current Requirement CALCULATINg CURRENT REQUIREMENT Questions about sizing wire and circuit breakers should be directed to a qualified electrician. Single Phase Power and Single Stage Elements (Element wiring Schematics A, A* and B') CURRENT = POwER / VOLTAgE example: to find the operating current for a 1500 watt heater that operates at 120 volts, divide 1500 watts by 120 volts to get current of 12.5 amps. Single Phase Power and Multi-Stage Elements (Element wiring Schematics B, B* and C) HEATER CURRENT = POwER / VOLTAgE STAgE CURRENT = HEATER CURRENT / (# of STAgES) example: to find the operating current for each stage of a 2-stage, 3000 watt heater operating at 120 volts, divide 3000 watts by 120 volts to get heater current of 25 amps. to get individual stage current, divide heater current by # of stages (2) to get 12.5 amps per stage. Single Phase Power and Dual Voltage Elements (Element wiring Schematics B, B* and B') dual voltage elements have multiple stages that can be wired to permit operation at different voltages. the low voltage configuration would be treated as a multi-stage heater described in the paragraph above. to wire the same element in a high voltage application would require wiring the stages in series (as shown in element Wiring Schematic b'). to determine the current draw for dual voltage HotZone electric heaters when wired for high voltage use the formula: HEATER CURRENT = POwER / VOLTAgE As the stages are in series, STAgE CURRENT = HEATER CURRENT 3-Phase Power and Multi-Stage Elements Delta Configuration (Element wiring Schematic D) LEg CURRENT = POwER / (VOLTAgE x # of STAgES) example: A 3-stage 5000 watt heater that runs on a 208 volt 3-phase supply and is wired in a delta configuration. to find the current in each leg of the 3-phase supply, divide 5000 watts by the product of 208 volts and the number of stages, which is 3. the resulting current in each leg would be 8 amps. 3-Phase Power and Multi-Stage Elements wye Configuration (Element wiring Schematic C) LEg CURRENT = POwER / (( VOLTS / 3 ) x # of STAgES) example: A 3-stage 5000 watt heater that runs on a 208 volt 3-phase supply and is wired in a Wye configuration. to find the current in each leg of the 3-phase supply divide 5000 watts by the product of 208 volts divided by the square root of 3 times the number of stages which is 3. the resulting current in each leg would be 13.9 amps. 15

16 Warranty Schaefer Ventilation Equipment, LLC Schaefer Limited warranty Policy Schaefer Ventilation Equipment, LLC (SVE) provides the following limited warranty from the date of invoice to the initial purchaser of our products or to its customer with a dated proof of purchase: I. Two-year coverage (unless otherwise indicated below) applies to all products, components and assemblies provided by SVE that prove to be defective in material or workmanship. Any such defective product will be repaired or replaced at SVE s option, with the defective product or component returned, upon approval, to SVE, F.O.B Sauk Rapids, Minnesota. II. This warranty does not cover: a. Failure, damage or malfunction as a result of: i. Improper installation or installation not in accordance with installation instructions. ii. Operating conditions that vary from SVE s operating instructions. iii. Misuse, abuse, negligence, alteration, or accident. iv. Transporting the product. v. Improper operation or lack of appropriate or regular maintenance of the product. b. Loss of time, inconvenience, loss of use of the product or other consequential or incidental damages. c. Parts that need replacement due to normal wear and tear. d. Superficial or cosmetic rust or corrosion. e. Any product whose name plate has been removed. Products with warranty periods that differ from the standard 2-year warranty are as follows: Poly Housings 25 years Fiberglass Housings 15 years Low-intensity Tube Heater Exchange Tubes 5 years Heavy-Duty Industrial Wash-Down Fans (with VWD motors) 3 years K-Series, 2-Stage, Compact and Stainless Steel Tube Heaters 1 year Quartz and Zubri Heaters 1 year Big Dog Fans 1 year Shutter Motors and Aluminum Riveted Fan Blades 1 year Epoxy Line Wash down fans (with EWD motors) 1 year Evaporative Cooling Pads 180 days HotZone Electric Elements 120 days Quartz Bulbs 90 days Tuff & Gusty Fans 90 days Any product or part as noted as an exception to the standard 2-year warranty in the product s operating manual. SVE reserves the right to add or delete products from this exception list at any time. THERE ARE NO WARRANTIES OF MERCHANTABILITY OR FITNESS OF USE. SVE reserves the right to change product design and specification without prior notice or liability. The above constitutes the sole warranty offered by Schaefer Ventilation Equipment, LLC. Effective March 1, All information, illustrations and specifications in these instructions are based on the latest product information available at the time of printing. Product specifications subject to change Schaefer Ventilation Equipment / M-HZELECTRIC

User Manual Box Exhaust Fan Series (Belt Drive)

User Manual Box Exhaust Fan Series (Belt Drive) User Manual Box Exhaust Fan Series (Belt Drive) 36" Box Exhaust Fan with Three Wing Blade Box with Aluminum Shutter 54" Box with Cone 800-779-3267 sales@schaeferfan.com www.schaeferfan.com 2013 Schaefer

More information

ELECTRIC STOVE HEATER Models: FS2213B

ELECTRIC STOVE HEATER Models: FS2213B ELECTRIC STOVE HEATER Models: FS2213B OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product. Failure to do so

More information

IMPORTANT SAFETY INFORMATION INSIDE

IMPORTANT SAFETY INFORMATION INSIDE Self-Contained Power Mister USER'S MANUAL PVM18C PVM18 Serious injury or death is possible. Retain these instructions for future reference. WARNING IMPORTANT SAFETY INFORMATION INSIDE Read, understand

More information

ELECTRIC FLAT PANEL FIREPLACE HEATER

ELECTRIC FLAT PANEL FIREPLACE HEATER ELECTRIC FLAT PANEL FIREPLACE HEATER Model Numbers: 80-2000A-42 OWNER S MANUAL AC 120V 60Hz 1500W WARNING Read and understand this entire owner s manual, including all safety information, before plugging

More information

HI Industrial Utility Heater HI Soleus Air International

HI Industrial Utility Heater HI Soleus Air International HI1-50-03 Industrial Utility Heater HI1-50-03 2010 Soleus Air International Thank you for choosing a Soleus Air Utility Heater. This owner s manual will provide you with valuable information necessary

More information

Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer) Panel Fan Series Operators Manual (Galvanized and Polymer) 52" Belt Drive, Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before

More information

NO VENTING REQUIRED 120V AC;

NO VENTING REQUIRED 120V AC; ELECTRIC FIREPLACE Model Number: Alice (EF172B-EF176B) OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product.

More information

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE 72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE Model Numbers: 80005 OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product.

More information

Gallery Electric Fireplaces

Gallery Electric Fireplaces Gallery Electric Fireplaces Homeowner s Installation Instructions & Operating Manual Model: GBL-44 FOR YOUR SAFETY SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY. DO NOT STORE OR USE GASOLINE

More information

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL WALL MOUNT ELECTRIC FIREPLACE EF-BLT13-36 EF-BLT13-42 EF-BLT13-50 EF-BLT13-60 OWNERS MANUAL NO VENTILATION REQUIRED PRODUCES SAFE AND EFFICIENT HEAT PLEASE READ THIS ENTIRE MANUAL BEFORE USING UNIT 120-VOLT

More information

ELECTRIC FLAT PANEL FIREPLACE HEATER

ELECTRIC FLAT PANEL FIREPLACE HEATER ELECTRIC FLAT PANEL FIREPLACE HEATER Model Numbers: WM50; WM-50-W; WS-G-01;WS-G-02 OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging

More information

Gallery Electric Fireplaces

Gallery Electric Fireplaces Gallery Electric Fireplaces Homeowner s Installation Instructions & Operating Manual Model: GBI-34, GBI-41 Only use this heater as described in this manual. Any other use is not recommended by the manufacturer,

More information

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80 Installation & Service Manual Models ALF 20, 30, 40, 50, 60, 80 IMPORTANT! Read all safety instructions before installing, using, or servicing the heater. Installation & servicing should only be carried

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 5,000W/240V WALL / CEILING MOUNTED GARAGE HEATER WITH ELECTRONIC CONTROLLER AND REMOTE OWNER S MANUAL IMPORTANT INSTRUCTIONS READ & SAVE Model: PH-950NR PET OWNERS WARNING: The health of some small pets

More information

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product.

More information

Hardwired Electric Garage Heater

Hardwired Electric Garage Heater Hardwired Electric Garage Heater G73 OWNERS MANUAL Read and save these instructions. 2 Trust has to be earned, and we will earn yours. Customer happiness is the focus of our business. From the factory

More information

Electric Garage Heater

Electric Garage Heater Electric Garage Heater G73 OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2 From the

More information

Wall Mount Electric Fireplace

Wall Mount Electric Fireplace Wall Mount Electric Fireplace User Guide Thank you for purchasing the Ivation Wall Mount Electric Fireplace. This User Guide is intended to provide you with guidelines to ensure that operation of this

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

Electric Fireplace Instruction Manual

Electric Fireplace Instruction Manual Electric Fireplace Instruction Manual Built-in Fireplaces DF-EFP1313-BLT Yosemite Home Décor 1-800-305-9872 www.yosemitehomedecor.com Quick Reference Guide 1. Prior to installation, please ensure: a. The

More information

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL Thank you for purchasing a Fire Sense Electric Fireplace. Important: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible

More information

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W Flat Wall Mounted / Free stand Electric Fireplace Model Numbers: 80-421S OWNER S MANUAL Wall Hanging Mode Freestanding Mode AC 120V / 60HZ 1500W WARNING Read and understand this entire owner s manual,

More information

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION ELECTRIC FLAT PANEL FIREPLACE HEATER Model Number: EFW-XB60B OWNER S MANUAL Wall Hanging Mode Pedestal Mode WARNING CAUTION Read and understand this entire owner s manual, including all safety information,

More information

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL NO VENTALATION REQUIRED PRODUCES SAFE AND EFFICIENT HEAT PLEASE READ THIS ENTIRE INSTRUCTION MANUAL BEFORE

More information

FLAME CUBE ELECTRIC FIREPLACE MODEL EF-BLT02 OPERATION MANUAL

FLAME CUBE ELECTRIC FIREPLACE MODEL EF-BLT02 OPERATION MANUAL FLAME CUBE ELECTRIC FIREPLACE MODEL EF-BLT02 OPERATION MANUAL PLEASE READ THIS ENTIRE INSTRUCTION MANUAL BEFORE USING 110~120VOLT 1350 WATTS SAVE THESE INSTRUCTIONS FOR FUTURE USE Quick Reference Guide

More information

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International Indoor/Outdoor Electric Patio Heater Model No: HP1-15-50 Operating Instructions 3098007 HP1-15-50 2009 Soleus Air International Thank you for choosing a Soleus Air Indoor/Outdoor Patio Heater. This owner

More information

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE HEATER Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL 36"/45"/50"/60"/72"/100" LED Wall Mounted Or Built-in Electric Fireplace AC 110-120V 60Hz 1500W WARNING

More information

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International HGW-308R Wall Mountable Micathermic Heater w/ Remote 3092402 Model No. HGW-308R 2007 Soleus Air International Thank you for choosing a Soleus Air Micathermic heater. This owner s manual will provide you

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 5000W Ceiling/Wall Mounted Garage Heater OWNER S MANUAL Model: PH-950N IMPORTANT INSTRUCTIONS READ & SAVE PET OWNERS WARNING: The health of some small pets including birds are extremely sensitive to the

More information

Hardwired Electric Garage Heater

Hardwired Electric Garage Heater Hardwired Electric Garage Heater G73 OWNERS MANUAL v1.0 Read and save these instructions. Manual v1.1 2 A Name You Can Trust Trust should be earned and we will earn yours. Customer happiness is the focus

More information

Gallery Electric Fireplaces

Gallery Electric Fireplaces Gallery Electric Fireplaces Homeowner s Installation Instructions & Operating Manual Model: GE-50, GE-58, GE-70, GE-78 GE-94 FOR YOUR SAFETY SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY. DO

More information

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL Alice In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information,

More information

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

ELECTRIC FIREPLACE HEATER OPERATION MANUAL ELECTRIC FIREPLACE HEATER Important Safety Instructions OPERATION MANUAL PLEASE RETAIN THIS USER S GUIDE FOR FUTURE REFERENCE When using electrical appliances, basic precautions should always be followed

More information

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0 Electric Fireplace Factory Model: EF-30D CONSUMER SAFETY INFORMATION Read this manual before installing and operating this appliance Failure to follow these instructions may result in electric shock, fire

More information

Electric Garage Heater

Electric Garage Heater Electric Garage Heater G56 OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2 From the

More information

ELECTRIC FIREPLACE OWNER S MANUAL

ELECTRIC FIREPLACE OWNER S MANUAL ELECTRIC FIREPLACE OWNER S MANUAL MODELS EL1346C 4001358 WARNING: If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury

More information

Summer Breeze Heater Service Manual

Summer Breeze Heater Service Manual Summer Breeze Heater Service Manual RSBH RSBH-SB RSBHP Revision: 1.0 Issued: 12-18-2012 Table of Contents I. Basic Assembly and Operation A. Safety Instructions... 2 B. Grounding Instructions... 3 C.

More information

User s Manual & Operating Instructions

User s Manual & Operating Instructions User s Manual & Operating Instructions Model Numbers REM-03-240-GH / REM-05-240-GH CONSUMER: READ AND SAVE THESE INSTRUCTIONS Use this heater only as described in this manual. Any other use not recommended

More information

MODELS HS 1300-WS HS-1500-CR HS-1300-TR

MODELS HS 1300-WS HS-1500-CR HS-1300-TR MODELS HS 1300-WS HS-1500-CR HS-1300-TR INFRARED ELECTRICAL HEATER safety instructions & operation manual INTRODUCTION The Heat Storm all season outdoor heater produces infrared radiant heat, warming people

More information

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT Tool list Assembly Instructions Important Safety Instructions Listing Approvals Glass Particles Installation Instructions

More information

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M PLEASE READ CAREFULLY BEFORE USE AND SAVE THESE IMPORTANT SAFEGUARDS PET OWNERS WARNING: The health of some small pets including birds are extremely

More information

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION: Owner s Manual Model CUH05B31T IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this heater. For your safety, always comply with all warnings and safety instructions

More information

VERNON ELECTRIC FIREPLACE

VERNON ELECTRIC FIREPLACE VERNON ELECTRIC FIREPLACE MODEL # 60351 CARE & USE GUIDE Please read this manual before installing and using your fireplace. IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, AN ELECTRICAL SHOCK

More information

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL Read these instructions completely before operating electric stove. Failure to follow them could cause a heater malfunction resulting

More information

Dayton Electric Infrared Fireplace User Manual

Dayton Electric Infrared Fireplace User Manual EL1239 WW13980 Dayton Electric Infrared Fireplace User Manual SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If you are assembling this unit for someone else, give this manual to him or her to read and

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE WALL/CEILING MOUNT HEATER OWNER S MANUAL Model No.: DR-966 6000W 240V 60HZ IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions.. 3 Specifications and Wiring Diagram 5 Parts of

More information

Wall Hanging Mode. Pedestal Mode

Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER Model Number: EFW-XB60D OWNER S MANUAL Wall Hanging Mode Pedestal Mode WARNING CAUTION Read and understand this entire owner s manual, including all safety information,

More information

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL NO VENTILATION REQUIRED PRODUCES SAFE AND EFFICIENT HEAT 110/120-VOLT 60Hz LED BULBS SAVE THESE INSTRUCTIONS FOR FUTURE USE 1 CONSUMER SARETY INSTRUCTIONS

More information

VERNON ELECTRIC FIREPLACE

VERNON ELECTRIC FIREPLACE VERNON ELECTRIC FIREPLACE MODEL # 60351 CARE & USE GUIDE Please read this manual before installing and using your fireplace. IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, AN ELECTRICAL SHOCK

More information

INFRARED ZONE HEATING SYSTEM

INFRARED ZONE HEATING SYSTEM INFRARED ZONE HEATING SYSTEM OWNER S MANUAL Model No. ATI-HF-X www.advancedtechinfrared.com PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE. Thank you for choosing

More information

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION ELECTRIC FIREPLACE INSERT Model No.: WESTERN (EF42D-45D) OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product.

More information

AH-600 Baseboard Heater

AH-600 Baseboard Heater AH-600 Baseboard Heater OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2 From the factory

More information

Quest Power Electric Heat EHS 31 Pro

Quest Power Electric Heat EHS 31 Pro Quest DRY Power 150 Electric Heat EHS 31 Pro Read and Save These Instructions The Power Electric Heat EHS 31 Pro portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed

More information

Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP404R-Q

Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP404R-Q Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP404R-Q PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE. PET OWNERS WARNING: The health of some small

More information

Electrical Fireplace Stove with Heater

Electrical Fireplace Stove with Heater Electrical Fireplace Stove with Heater OWNER S MANUAL Model No. FP201R PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE. Thank you for choosing our Electric Fireplace.

More information

QCM979D-38AGO ELECTRIC FIREPLACE HEATER NDF-65NB-3 INSTRUCTION MANUAL

QCM979D-38AGO ELECTRIC FIREPLACE HEATER NDF-65NB-3 INSTRUCTION MANUAL ELECTRIC FIREPLACE HEATER INSTRUCTION MANUAL QCM979D-38AGO NDF-65NB-3 ATTENTION: 1. Find a location for the fireplace heater that is protected from direct sunlight. 2. Do not plug the unit into the power

More information

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL Model No.: SPP1500SBH PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE Thank you for choosing the Versonel Digital Quartz

More information

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1 GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E Figure 1 PET OWNERS WARNING: Health warning for some small pets, including birds, as they are extremely sensitive to the fumes produced

More information

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION: Owner s Manual Model DS7420 DS7425DLX IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this stove. For your safety, always comply with all warnings and safety

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

Model: M630-44FDC CAUTION:

Model: M630-44FDC CAUTION: Electric FIREPLACE Heater Model: M630-44FDC IMPORTANT: Please note: when you open the carton, carefully check the unit and make sure there is no damage. If you have any problems with the unit, with how

More information

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION: Owner s Manual Models CS4416 CS3311 CS2307 CS3311 Pictured IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this stove. For your safety, always comply with

More information

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL NO VENTING REQUIRED PRODUCES SAFE EFFICIENT HEAT 110-120-VOLT / 1500-WATT READ ENTIRE MANUAL BEFORE USING SAVE THIS MANUAL FOR FUTURE USE 1 SAFETY

More information

Motion Sensor Oscillating Heater with Digital Control

Motion Sensor Oscillating Heater with Digital Control Motion Sensor Oscillating Heater with Digital Control 33553 Part# NFE20C INSTRUCTION MANUAL Please Read And Save These Instructions 1 IMPORTANT SAFETY INSTRUCTIONS Please read these instructions carefully

More information

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater Concept S-2 Indoor Infrared Stove Heater RedCore Stove Heater 2011-04-20 CUSTOMER SUPPORT DO NOT RETURN THIS PRODUCT TO THE STORE WHERE YOU BOUGHT IT FOR IMMEDIATE CUSTOMER SERVICE, PLEASE CALL: 888-4BGT

More information

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL ELECTRIC FIREPLACE HEATER INSTRUCTION MANUAL M650-38A-OAK NDF-65NB-1 ATTENTION: 1. Find a location for the fireplace heater that is protected from direct sunlight. 2. Do not plug the unit into the power

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Portable High Temperature Blower Attention: Do not operate this heater in explosive areas. Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater

More information

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Dallas Floor Standing Fireplace

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Dallas Floor Standing Fireplace IMPORTANT INSTRUCTIONS & OPERATING MANUAL Dallas Floor Standing Fireplace Item No: DSF-1/0302 Read these instructions carefully before attempting to assemble, install, operate or maintain the product.

More information

Electric Fireplace Insert with Heater

Electric Fireplace Insert with Heater Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP406R-Q PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE. PET OWNERS WARNING: The health of some small

More information

INFRARED QUARTZ HEATER

INFRARED QUARTZ HEATER INFRARED QUARTZ HEATER OWNER S MANUAL Model No. GD9315BC1-N PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE. Thank you for choosing a PROFUSION HEAT Infrared Quartz

More information

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International HM1-10-32 & HM1-10-01 Ultra Thin Micathermic Heater Model No. HM1-10-32 / HM1-10-01 2007 Soleus Air International Thank you for choosing a Soleus Air Micathermic heater. This owner s manual will provide

More information

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz Fan Forced HEATER OWNER S MANUAL Model No.: DR218-1500 1500W 120V 60Hz DR218-3000 3000W 240V 60Hz IMPORTANT INSTRUCTIONS READ & SAVE TABLE OF CONTENTS Important Instructions. 3 Specifications and Wiring

More information

EA0045RC ELECTRIC FIREPLACE

EA0045RC ELECTRIC FIREPLACE EA0045RC ELECTRIC FIREPLACE SAVE THIS MANUAL You will need this manual for safety instructions, operation procedures, and warranty. Put it and the original invoice in a safe, dry place for future reference.

More information

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control Electric Patio Heater Ceiling Type Model: ZHQ2068-RMLED Operating Instruction WARNING: This heater is not equipped with a device to control the room temperature. Do not use this heater in small rooms when

More information

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) Galvanized Panel Fan IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble, install, operate

More information

Owner s Manual Phoenix FireBird

Owner s Manual Phoenix FireBird 4201 Lien Rd Madison, WI 53704 Owner s Manual Phoenix FireBird Installation, Operation and Service Instructions Important Instructions Read and Save These Instructions The FireBird portable, heavy duty

More information

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL

More information

Homeowner s Installation Instructions & Operating Manual

Homeowner s Installation Instructions & Operating Manual Wall Mounted Electric Fireplace Homeowner s Installation Instructions & Operating Manual Model: EF67B Series Used With Listed Front Facia Only: MT67C01 Black flat glass MT67C02 Black curved glass FOR YOUR

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 10,000W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL IMPORTANT INSTRUCTIONS READ & SAVE Model No.: DR-910F 10,000W 240V 60Hz 1 TABLE OF CONTENTS Important Instructions.3 Installing Instructions.

More information

INFRARED QUARTZ HEATER

INFRARED QUARTZ HEATER INFRARED QUARTZ HEATER OWNER S MANUAL Model No. VSL1500H6E Versonel New Holland, PA www.versonel.com PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE. Thank you for

More information

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION ELECTRIC FLAT PANEL FIREPLACE Model# :80017 OWNER S MANUAL 50/60 - Built-in & Wall Mounted Electric Fireplace AC 110-120V 60Hz WARNING Read and understand this entire owner s manual, including all safety

More information

AH-400 Oil Filled Personal Heater

AH-400 Oil Filled Personal Heater AH-400 Oil Filled Personal Heater OWNERS MANUAL Read and save these instructions. Manual v1.1 2 A Name You Can Trust Trust should be earned and we will earn yours. Customer happiness is the focus of our

More information

Zubri Portable Heater

Zubri Portable Heater Zubri Portable Heater Propane Gas Heater - 40,000 BTU USER'S MANUAL WARNING Important safety precautions are described in these instructions! They must be read before using the Zubri Z1-12 patio heater

More information

Infrared Portable Space Heater

Infrared Portable Space Heater Infrared Portable Space Heater 1500 Watts with Two Heat Settings Automatic Thermostat Tip-Over Switch Room Temperature LED Display Precision Temperature Control Easy Push-Button Controls Remote Control

More information

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions. Flat Panel Micathermic Space Heater AH-470 OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business.

More information

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM SH-1500LCD PLEASE READ THIS MANUAL 12 Safety Notice Please read this entire Operation and Warranty Manual BEFORE operating your new

More information

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION: Owner s Manual Model G70 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this heater. For your safety, always comply with all warnings and safety instructions

More information

Low Profile. Baseboard Heater

Low Profile. Baseboard Heater Low Profile AH-600 Baseboard Heater OWNERS MANUAL v1.0 Read and save these instructions. 2 A Name You Can Trust Trust should be earned and we will earn yours. Customer happiness is the focus of our business.

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 7,500W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL Model: DR-975 7500W 240V 60Hz IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions. 3 Installation Instructions...

More information

Manual for Ceiling Patio Heater

Manual for Ceiling Patio Heater Manual for Ceiling Patio Heater 13-01-2017 Please read these instructions carefully before using your new halogen heater. Thank you for choosing our Indoor/Outdoor Patio Heater. This owner s manual will

More information

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters Owner s Manual File E97759 COMFORT S for INDOOR* and OUTDOOR** USE *Excluding Residences ** With Quartz Elements and when mounted Underneath

More information

Installation and Operation Instructions ELECTRIC FIREPLACE X30WMEF1BLK X30WMEF1WHT

Installation and Operation Instructions ELECTRIC FIREPLACE X30WMEF1BLK X30WMEF1WHT Installation and Operation Instructions ELECTRIC FIREPLACE X30WMEF1BLK X30WMEF1WHT 1 Important Safety Instructions Listing Approvals Product Dimensions Locating Fireplace Unpacking and Testing Fireplace

More information

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5 TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance

More information

AH-450B Oil-Filled Radiator Heater OWNERS MANUAL

AH-450B Oil-Filled Radiator Heater OWNERS MANUAL AH-450B Oil-Filled Radiator Heater OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2

More information

ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL

ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL Only use this heater as described in this manual. Any other use is not recommended by the manufacturer, and may cause fire, electric shock, or

More information

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS TRUSTED FOR OVER 100 YEARS Heater with Adjustable Thermostat * Fan-Forced Heaters may appear with a different grill design NOTE: A Phillips screwdriver is required for assembly. Instruction Leaflet PLEASE

More information

tungsten Smart-heat electric heater

tungsten Smart-heat electric heater tungsten Smart-heat electric heater BY BROMIC Installation, instruction and service manual SUITABLE FOR electric HEATER MODELS: tungsten 2000w, 3000W, 4000W- AND tungsten 6000w Version 1.5 USA! IMPORTANT

More information

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION, INSTRUCTION AND SERVICE MANUAL TUNGSTEN SMART-HEAT ELECTRIC HEATER BY BROMIC INSTALLATION, INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS: TUNGSTEN 2000W, 3000W, 4000W- AND TUNGSTEN 6000W Version 1.7 USA! IMPORTANT

More information

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE MODEL NUMBERS: 23 Electric Stove Quality checked by: Valued Customer, We are pleased that you have chosen to purchase an electric stove manufactured by Dimplex

More information

EF5528RKD Freestanding Electric Fireplace

EF5528RKD Freestanding Electric Fireplace EF5528RKD Freestanding Electric Fireplace Installation Instructions and Homeowner's Manual WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE,

More information