1 SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant Copper tube/aluminum fin condenser and evaporator coils Scroll compressor standard on all models Short cycling protection for the compressor is built into the defrost control board Dehumidification mode (airflow reduction) on all models EASY TO INSTALL AND SERVICE Installs easily on a rooftop or at ground level Easy three panel accessibility for maintenance and installation Easily converts to down discharge applications Combination electric heating and cooling BUILT TO LAST High efficiency ECM indoor blower motor on all models Pre painted steel cabinet Vertical condenser fan discharge Hail guard (3/8 spacing) wire grilles standard on PHD3**000KTP models (2 spacing wire grilles on non-tin models) Full perimeter steel base rails High and low pressure switches provide added reliability for the compressor All models available with optional factory installed tin coated copper evaporator coil (These models are identified with letters TP in the 11th and 12th positions in the model number) WARRANTY* 1 year No Hassle Replacement limited warranty for models with tin coated copper evaporator coils 5 year parts limited warranty (including compressor and coils) With timely registration, an additional 5 year parts limited warranty (including compressor and coils) *Applies to original purchaser/homeowner, some limitations may apply. See warranty certificate for complete details. Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to UNIT PERFORMANCE DATA COOLING HEATING Unit Dimensions Operating Model Height x Width x Depth Weight Number BTU/h SEER EER BTU/h HSPF in (mm) lbs (kg) PHD324000K000C 23, , x48 3 / 16 x32 5 / 8 (1065x1224x829) 320 (145) PHD324000KTP0C 23, , x48 3 / 16 x32 5 / 8 (1065x1224x829) 320 (145) PHD330000K000C 29, , x48 3 / 16 x32 5 / 8 (1065x1224x829) 332 (150) PHD330000KTP0C 29, , x48 3 / 16 x32 5 / 8 (1065x1224x829) 332 (150) PHD336000K000C 35, , x48 3 / 16 x32 5 / 8 (1116x1224x829) 336 (152) PHD336000KTP0C 35, , x48 3 / 16 x32 5 / 8 (1116x1224x829) 336 (152) PHD342000K000C 40, , / 8 x48 3 / 16 x44 1 / 8 (1165x1224x1123) 441 (186) PHD342000KTP0C 40, , / 8 x48 3 / 16 x44 1 / 8 (1165x1224x1123) 441 (186) PHD348000K000C 47, , / 8 x48 3 / 16 x44 1 / 8 (1165x1224x1123) 429 (194) PHD348000KTP0C 47, , / 8 x48 3 / 16 x44 1 / 8 (1165x1224x1123) 429 (194) PHD360000K000C 57, , / 8 x48 3 / 16 x44 1 / 8 (1265x1224x1123) 454 (206) PHD360000KTP0C 57, , / 8 x48 3 / 16 x44 1 / 8 (1265x1224x1123) 454 (206) Specifications subject to change without notice. 9/16/10

2 MODEL SERIES P = Package MODEL NOMENCLATURE ,6 7,8, , P H D K 00 0 C 1 H = Heat Pump TYPE D = Standard TIER 3 = 13 4 = 14 5 = 15 SEER 24 = 24,000 BTUH = 2 Tons 30 = 30,000 BTUH = 2.5 Tons 36 = 36,000 BTUH = 3 Tons 42 = 42,000 BTUH = 3.5 Tons 48 = 48,000 BTUH = 4 Tons 60 = 60,000 BTUH = 5 Tons NOMINAL COOLING CAPACITY 000 = no factory heat NOMINAL HEATING BTUH (input) K = 208/ = No options TP = Tin Plated Evaporator Main Tubes VOLTAGE FACTORY INSTALLED OPTIONS 0 = Standard FEATURE CODE Sales Model Digit Engineering Digit AHRI* CAPACITIES COOLING CAPACITIES AND EFFICIENCIES UNIT PHD3 NOMINAL TONS STANDARD CFM COOLING CAPACITIES (Btuh) EER** SEER , / , , / , , , HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES HEATING UNIT PHD3 CAPACITY 47 F (8.3 C) 47 F (8.3 C) HEATING CAPACITY 17 F (-8.3 C) 17 F (-8.3 C) HSPF 24 23, , , , , , , , , , , , LEGEND db Sound Levels (decibels) db Dry Bulb SEER Seasonal Energy Efficiency Ratio wb Wet Bulb COP Coefficient of Performance HSPF Heating Season Performance Factor * Air Conditioning, Heating, & Refrigeration Institute. **At A conditions 80 F (26.7 C) indoor db/67 F (19.4 C) indoor wb & 95 F (35 C) outdoor db. Rated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or AHRI Standards 210/240. Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80 F (26.7 C) db, 67 F (19.4 C) wb indoor entering air temperature and 95 F (35 C) db outdoor entering air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 2

3 ELECTRICAL DATA PHD3 VOLTAGE RANGE COMPRESSOR OFM IFM ELECTRIC HEAT POWER SUPPLY UNIT NOMINAL V PH HZ MIN MAX RLA LRA MCC FLA FLA NOMIN kw 208v/230v FLA 208v/230v MCA 208v/230v MOCP 208v/230v / / PHD / /5 18.1/ / /50 5.4/ / / /60 7.5/ / / /80 / / /5 18.1/ / /60 PHD / / / / /70 7.5/ / / / / / / /110 / / /5 18.1/ / /60 79 PHD / / / / /70 7.5/ / / / / / / /110 / / /5 18.1/ / /60 PHD / / / / /80 7.5/ / / / / / / /125 15/ / / /150 / / /5 18.1/ / /70 PHD / / / / /80 7.5/ / / / / / / /125 15/ / / /150 / / /5 18.1/ / /70 PHD / / / / /90 7.5/ / / / / / / /125 15/ / / /150 LEGEND FLA = Full Load Amps LRA = Locked Rotor Amps MCA = Minimum Circuit Ampacity MOCP = Maximum Overcurrent Protection RLA = Rated Load Amps 1. In compliance with NEC (National Electrical Code) requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be Power Supply fuse. The CGA (Canadian Gas Association) units may be fuse or circuit breaker. 2. Minimum wire size is based on 60 C copper wire. If other than 60 C wire is used, or if length exceeds wire length in table, determine size from NEC. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 3

4 PHYSICAL DATA UNIT PHD3 UNIT SIZE NOMINAL CAPACITY (ton) SHIPPING WEIGHT (lb) (kg) COMPRESSOR QUANTITY 1 TYPE SCROLL COMPRESSOR REFRIGERANT R-410A Quantity (lb) Quantity (kg) METERING DEVICE ID TXV ORIFICE OD (in.) (2) (2) (2) (mm) /1.02 OUTDOOR COIL Rows... Fins/in face area (sq. ft.) OUTDOOR FAN Nominal Airflow (CFM) Fan Diameter (in.) Fan Diameter (mm) Diameter Motor HP (RPM) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) INDOOR COIL INDOOR BLOWER HIGH-PRESSURE SWITCH (psig) LOSS-OF-CHARGE/ LOW-PRESSURE SWITCH RETURN-AIR FILTERS* Rows... Fins/in. face area (sq. ft.) Nominal Cooling Airflow (CFM) Size (in.) (mm) Motor (HP) Cutout Reset (Auto) (Liquid Line) (psig) Cutout Reset (Auto) throwaway (in.) (mm) x10 254x254 1/2 20x20x1 508x508x x10 254x254 1/2 20x24x1 508x610x (Left OD Coil) (Right OD Coil) SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE x10 279x254 3/ x10 279x254 3/4 650±15 420±25 20±5 45±10 24x30x1 610x762x (2) /5 (810) x10 279x x36x1 610x914x (2) /5 (810) x10 279x *Required filter sizes shown are based on the larger of the AHRI (Air conditioning, Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high capacity type. Air filter pressure drop for non standard filters must not exceed 0.08 Iin wc. If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity. DRY COIL AIR DELIVERY* HORIZONTAL AND DOWNFLOW DISCHARGE UNIT PHD UNIT MOTOR WIRE EXTERNAL STATIC PRESSURE (in wc) SPEED COLOR Low Blue CFM Med-Low Pink CFM PHD324 Medium 1 Red CFM Med-High Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM PHD330 Medium Red CFM Med-High 1 Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM PHD336 Medium 1 Red CFM Med-High Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM PHD342 Medium Red CFM Med-High 1 Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM PHD348 Medium 1 Red CFM Med-High Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM PHD360 Medium 1 Red CFM Med-High Orange CFM High Black CFM * Air delivery values are without air filter and are for dry coil (See PHD3 Horizontal Wet Coil Pressure Drop Table). 1 Factory shipped cooling speed NOTE: For horizontal applications deduct field supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. For downflow applications see Wet Coil Air Delivery Table for available static including wet coil, 1 in. (25 mm) filter and economizer. Shaded areas indicate speed/static combinations that are not permitted for dehumidification speed.

5 HORIZONTAL WET COIL PRESSURE DROP (in wc) STANDARD CFM (S.C.F.M.) UNIT SIZE DOWNFLOW WET COIL AIR DELIVERY (CFM) HIGH SPEED WITH 1 IN. (25 MM) FILTER AND ECONOMIZER UNIT SIZE EXTERNAL STATIC PRESSURE (in wc) HORIZONTAL FILTER PRESSURE DROP TABLE (in wc) FILTER SIZE CFM in. (mm) X20X1 (508X508X25) X24X1 (508X610x25) X30X1 (610X762x25) X36X1 (610X914X25) ECONOMIZER 1 IN. FILTER PRESSURE DROP (in wc) UNIT PHD3 PRESSURE DROP MULTIPLICATION FACTORS HEATER kw RATING VOLTAGE DISTRIBUTION MULTIPLICATION FACTOR ELECTRIC HEAT PRESSURE DROP TABLE (in wc) SMALL CABINET: PHD CFM kw kw kw kw ELECTRIC HEAT PRESSURE DROP TABLE (in wc) LARGE CABINET PHD CFM kw kw kw kw kw MINIMUM AIRFLOW FOR RELIABLE ELECTRIC HEATER OPERATION (CFM) SIZE PHD324 PHD330 PHD336 PHD342 PHD348 PHD360 AIRFLOW (CFM) A WEIGHTED SOUND POWER LEVEL (dba) STANDARD RATING MODEL PHD3 (dba) TYPICAL OCTAVE BAND SPECTRUM (dba) (without tone adjustment) NOTE: Tested in accordance with AHRI Standard 270 (not listed in AHRI). SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 5

6 6 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE PHD324 COOLING EXTENDED PERFORMANCE TABLE EVAPORATOR AIR CFM / BF 700 / / / 0.20 EWB CONDENSER ENTERING AIR TEMPERATURES 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) Sens KW Sens KW Sens KW Sens KW Sens KW Sens 57 (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) *At 75 F (23.9 C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F (26.7 C) entering dry bulb. See Legend and Notes. PHD324 HEATING EXTENDED PERFORMANCE TABLE INDOOR AIR EDB CFM OUTDOOR COIL ENTERING AIR TEMPERATURES -10 (-23.3) 0 (-17.8) 10 (-12.2) 20 (-6.7) 30 (-1.1) 40 (4.4) 50 (10) 60 (15.6) Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ See Legend and Notes following tables. KW KW

7 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 7 PHD330 COOLING EXTENDED PERFORMANCE TABLE EVAPORATOR AIR CFM / BF 875 / / / 0.21 EWB CONDENSER ENTERING AIR TEMPERATURES 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) Sens KW Sens KW Sens KW Sens KW Sens KW Sens 57 (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) *At 75 F (23.9 C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F (26.7 C) entering dry bulb. See Legend and Notes. PHD330 HEATING EXTENDED PERFORMANCE TABLE INDOOR AIR EDB CFM OUTDOOR COIL ENTERING AIR TEMPERATURES -10 (-23.3) 0 (-17.8) 10 (-12.2) 20 (-6.7) 30 (-1.1) 40 (4.4) 50 (10) 60 (15.6) t em Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ See Legend and Notes following tables. KW t em KW

8 8 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE PHD336 COOLING EXTENDED PERFORMANCE TABLE EVAPORATOR AIR CFM / BF 1050 / / / 0.24 EWB CONDENSER ENTERING AIR TEMPERATURES 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) Sens KW Sens KW Sens KW Sens KW Sens KW Sens 57 (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) *At 75 F (23.9 C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F (26.7 C) entering dry bulb. See Legend and Notes. PHD336 HEATING EXTENDED PERFORMANCE TABLE INDOOR AIR EDB CFM OUTDOOR COIL ENTERING AIR TEMPERATURES -10 (-23.3) 0 (-17.8) 10 (-12.2) 20 (-6.7) 30 (-1.1) 40 (4.4) 50 (10) 60 (15.6) Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ See Legend and Notes following tables. KW KW

9 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 9 PHD342 COOLING EXTENDED PERFORMANCE TABLE EVAPORATOR AIR CFM / BF 1225 / / / 0.19 EWB CONDENSER ENTERING AIR TEMPERATURES 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) Sens KW Sens KW Sens KW Sens KW Sens KW Sens 57 (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) *At 75 F (23.9 C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F (26.7 C) entering dry bulb. See Legend and Notes. PHD342 HEATING EXTENDED PERFORMANCE TABLE INDOOR AIR EDB CFM OUTDOOR COIL ENTERING AIR TEMPERATURES -10 (-23.3) 0 (-17.8) 10 (-12.2) 20 (-6.7) 30 (-1.1) 40 (4.4) 50 (10) 60 (15.6) Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ See Legend and Notes following tables. KW KW

10 10 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE PHD348 COOLING EXTENDED PERFORMANCE TABLE EVAPORATOR AIR CFM / BF 1400 / / / 0.21 EWB CONDENSER ENTERING AIR TEMPERATURES 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) Sens KW Sens KW Sens KW Sens KW Sens KW Sens 57 (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) *At 75 F (23.9 C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F (26.7 C) entering dry bulb. See Legend and Notes. PHD348 HEATING EXTENDED PERFORMANCE TABLE INDOOR AIR EDB 65 (18.3) 70 (21.1) 75 (23.9) CFM OUTDOOR COIL ENTERING AIR TEMPERATURES -10 (-23.3) 0 (-17.8) 10 (-12.2) 20 (-6.7) 30 (-1.1) 40 (4.4) 50 (10) 60 (15.6) Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ See Legend and Notes following tables. KW KW

11 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 PHD360 COOLING EXTENDED PERFORMANCE TABLE EVAPORATOR AIR EWB CFM / BF 1750 / / / 0.27 CONDENSER ENTERING AIR TEMPERATURES 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) Sens KW Sens KW Sens KW Sens KW Sens KW Sens 57 (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) (13.9) (16.7) * (17.2) (19.4) (13.9) *At 75 F (23.9 C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F (26.7 C) entering dry bulb. See Legend and Notes. PHD360 HEATING EXTENDED PERFORMANCE TABLE INDOOR AIR EDB CFM OUTDOOR COIL ENTERING AIR TEMPERATURES -10 (-23.3) 0 (-17.8) 10 (-12.2) 20 (-6.7) 30 (-1.1) 40 (4.4) 50 (10) 60 (15.6) Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ KW Integ LEGEND BF - Bypass Factor edb - Entering Dry-Bulb Ewb - Entering Wet-Bulb kw - Unit Power Input SHC - Sensible Heat (1000 Btuh) TC - (1000 Btuh) (net) rh - Relative Humidity COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator-fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: t Sensible capacity (Btuh) ldb = t edb x cfm t lwb = Wet-bulb temperature corresponding to enthalpy air leaving evaporator coil ( h lwb) KW h total capacity (Btuh) lwb = h ewb x cfm Where: h ewb = Enthalpy of air entering evaporator coil 4. The SHC is based on 80 F (26.7 C) edb temperature of air entering evaporator coil. Below 80 F (26.7 C) edb, subtract (corr factor x cfm) from SHC. Above 80 F (26.7 C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 6. The SHC is based on 80 F (26.7 C) edb temperature of air entering evaporator coil. Below 80 F (26.7 C) edb, subtract (corr factor x cfm) from SHC. Above 80 F (26.7 C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 7. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. KW

12 UNIT DIMENSIONS, PHD EZ SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

13 UNIT DIMENSIONS, PHD EZ SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 13

14 TYPICAL C0NNECTION WIRING SCHEMATIC PHD3 208/ SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

15 TYPICAL LADDER WIRING SCHEMATIC PHD3 208/ SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 15

16 CONTROLS Operating sequence When power is supplied to unit, the transformer (TRAN) is energized. On units with crankcase heater, heater is also energized. Cooling With the thermostat in the cooling position, the thermostat makes circuit R to O. This energizes the reversing valve solenoid (RVS) and places the unit in standby condition for cooling. As the space temperature rises, the thermostat closes circuit R to Y. A circuit is made to contactor (C), starting the compressor (COMP) and outdoor fan motor (OFM). Circuit R to G is made at the same time and starts the indoor fan motor (IFM). When the thermostat is satisfied, contacts open, deenergizing C. The COMP and OFM stop, and the IFM stops after the preselected time delay. On the loss of the thermostat call for cooling, 24 V is removed from both the Y1/Y and G terminals (provided the fan switch is in the AUTO position) de energizing the compressor contactor and opening the contacts supplying power to compressor/ofm. After a 90 second delay, the IFM shuts off. If the thermostat fan selector switch is in the ON position, the IFM will run continuously. Heating On a call for heat, thermostat makes circuits R to Y and R to G. A circuit is made to C, starting COMP and OFM. Circuit R to G also is completed, energizing IFR and starting IFM after the selected time delay. Should room temperature continue to fall, circuit R to W is made through second stage thermostat. If optional electric heat package is used, a relay is energized, bringing on first bank of supplemental electric heat. When thermostat is satisfied, contacts open, deenergizing contactor and relay; motors and heaters deenergize. 16 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

17 ACCESSORIES ROOF CURBS HVAC unit base rails HVAC unit basepan C B Dashed lines show cross support location for large basepan units. Sealing Gasket Roofcurb F Anchor screw Flashing field supplied Roofing material field supplied Wood nailer* Roofcurb* Insulation (field supplied) A Cant strip field supplied D E COMMON CURB A09096 *Provided with roofcurb ROOF CURB DETAIL A09090 C B SUPPLY AIR SMALL BASE UNIT F A RETURN AIR LARGE BASE UNIT E D UNIT PLACEMENT ON COMMON CURB A09094 LARGE CURB A09095 SMALL OR LARGE BASE UNIT UNIT SIZE Small or Large Large CATALOG NUMBER A IN. (mm) CPRFCURB010A00 11 (279) CPRFCURB011A00 14 (356) CPRFCURB012A00 11 (279) CPRFCURB013A00 14 (356) B (small base) IN. (mm)* B (large base) IN. (mm)* C IN. (mm) D IN. (mm) E IN. (mm) 10 (254) 32.4 (822) 14 (356) 16 (406) 47.8 (1214) N/A 43.9 (1116) F IN. (mm) * Part Numbers CPRCURB010A00 and CPRCURB011A00 can be used on both small and large basepan units. The cross supports must be located based on whether the unit is a small basepan or a large basepan. NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Roof curb is made of 16 gauge steel. 4. Attach ductwork to curb (flanges of duct rest on curb). 5. Insulated panels: 1 in. (25.4 mm) thick fiberglass 1 lb. density. 2.7 (69) SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 17

18 PHD3 ACCESSORIES (continued) Accessory Model Number Description Use With Model Size ROOF CURBS CPRFCURB010A00 Roof Curb, 11 High CPRFCURB011A00 Roof Curb, 14 High CPRFCURB012A00 Roof Curb, 11 High CPRFCURB013A00 Roof Curb, 14 High Note: CPRFCURB010A00 AND CPRFCURB011A00 can be used with size units with some overhang. ADAPTER CURBS* CPADCURB001A00 Adapter curb for use with NPRFCURB006A00 & NPRFCURB007A CPADCURB002A00 Adapter curb for use with NPRFCURB008A00 & NPRFCURB009A * Can also be used when replacing other manufacturer s older generation units that contain a composite base without a metal base rail. CONCENTRIC ADAPTERS (Use with curb only) NPCONADP001A00 For 18 round duct (use with curbs CPRFCURB010A00, CPRFCURB011A00) Small Curb NPCONADP002A00 For 18 round duct (use with curbs CPRFCURB012A00, CPRFCURB013A00) Large Curb CONCENTRIC DIFFUSERS (Ceiling or under roof)) AXB020CSA* Step Down Diffuser Fits 2 x 4 Ceiling Grid (16 round collars for flex conn.) AXB020CFA* Flush Mount Diffuser Fits 2 x 4 Ceiling Grid (16 round collars for flex conn.) AXB030CSA Step Down Diffuser Fits 2 x 4 Ceiling Grid (18 round collars for flex conn.) AXB030CFA Flush Mount Diffuser Fits 2 x 4 Ceiling Grid (18 round collars for flex conn.) * A field supplied 18 to 16 round reducer required when used with NP concentric adaptor ECONOMIZERS CPECOMZR007A00 Dedicated Vertical Economizer Internal with solid state controller, gear driven, fully modulating CPECOMZR008A00 damper, spring return actuator, up to 50% barometric relief, supply and dry bulb outdoor 42, 48 CPECOMZR009A00 air sensors. Includes filter rack with 1 filters*. 60 CPECOMZR010A00 Dedicated Horizontal Economizer Internal with solid state controller, fully modulating CPECOMZR011A00 damper, spring return actuator, supply and dry bulb outdoor air sensor, and low ambient compressor 42, 48 CPECOMZR012A00 lockout switch included. Includes filter rack with 1 inch filters*. 60 CPRLYKIT001A00 Economizer relay for heat pumps ALL AXB078ENT Outdoor Enthalpy Control ALL * Outdoor enthalpy available as field installed accessory; Filter rack and 1 filter, same as CPFILTRK kit MANUAL FRESH AIR DAMPERS CPMANDPR007A CPMANDPR008A00 Manual Outside Air Damper (Includes filter rack and 1 filter, same as CPFILTRK kit) 42, 48 CPMANDPR009A00 60 INTERNAL FILTER RACK and FILTER (shipped with 1 filters) CPFILTRK007A CPFILTRK008A00 Internal Filter Rack 42, 48 CPFILTRK009A00 60 LOW AMBIENT, ANTI CYCLE TIMER, COMPRESSOR START ASSIST CPLOWAMB001A00 Low Ambient Control enables cooling system to operate down to 0 Deg. F by cycling condenser fan on and off. ALL NRTIMEGD001A00 Five Minute Compressor Delay ALL CPHSTART002A00 PTC Compressor Start Assist Kit ALL CRANKCASE HEATER BELLY BAND TYPE NPCRKHTR008A00 240V Crankcase Heater (included on 30 size) 24, 36 NPCRKHTR004A00 240V Crankcase Heater (included on 60 size) 48 HAIL GUARDS / COIL PROTECTION (Factory installed on PHD3**000KTP models) NAPA00501GR 3/8 spacing dense wire grilles NAPA00601GR 3/8 spacing dense wire grilles NAPA01001GR 3/8 spacing dense wire grilles 60 ELECTRIC HEATERS 208/240V PART NO. NOMINAL CAPACITY (kw) FUSED # FUSES STAGES USE WITH EHNA05K0N 3.8 / 5.0 NO EHNA05K4F 3.8 / 5.0 YES 4 1 ALL EHNA07K4F 5.4 / 7.2 YES 4 2 ALL EHNA10K4F 7.5 / 10.0 YES 4 2 ALL EHNA15K6F 11.3 / 15.0 YES EHNA20K6F 15.0 / 20.0 YES DUAL POINT WIRING KIT CPDUALPT001A00 Dual Point Wiring kit, 5 20kW Heaters ALL DUCT TRANSITIONS NPDUCFLG002A00 Square to Round (1 set of 2, use with horizontal duct flanges only) International Comfort Products, LLC Lewisburg, Tennessee USA 18 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant Scroll

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single --- And Three ---Phase Units 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron 50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product

More information

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) 607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data A09033 Fig. 1 - Unit 607C - -A Single-Packaged Products

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information

Product Data. Fig. 1 - Unit 50ES -A

Product Data. Fig. 1 - Unit 50ES -A 50ES---A Comfortt 13 SEER Single---Packaged Air Conditioner tem With Puron (R---410A) Refrigerant Single and Three Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50ES -A A09034

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Package Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. Fig. 1 - Unit 50VL -A

Product Data. Fig. 1 - Unit 50VL -A 50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single--- And Three---Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VL -A A09033

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. 13 SEER

More information

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Product Data. Fig. 1 - Unit 50VL -A

Product Data. Fig. 1 - Unit 50VL -A 50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VL -A A09033 Single-Packaged

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. Fig. 1 - Unit 50XL -A

Product Data. Fig. 1 - Unit 50XL -A 50XL---A Infinityr 15 SEER Single---Packaged Air Conditioner with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50XL -A A09032 Single-Packaged

More information

Product Data PA4G - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

Product Data PA4G - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data Fig. 1 - Unit - -A A09183 Single-Packaged Products with Energy

More information

Model 704B Sizes

Model 704B Sizes SINGLE-PACKAGED ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant Model 704B Sizes 024-060 2 To 5 Nominal Tons UNIT 704B Single-Packaged Products with Energy-Saving Features and Puron refrigerant.

More information

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons (60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits Product Data 50ZH Single-Packaged Heat Pumps 2 to 5 Tons Single-Package Heat Pump Units with: easy installation design corrosion-proof basepan redesigned aerodynamic fan blade for reduced sound sloped

More information

Product Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES )

Product Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES 024-060) Product Data Fig. 1 - Unit A06079 Single-Packaged Products with Energy

More information

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3 SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS Model 702A 2 to 5 Nominal Tons UNIT 702A Single packaged Cooling Unit for Residential and Light Commercial use. FEATURES/BENEFITS One-piece cooling unit with

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Product Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES )

Product Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES ) SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES 024-060) Product Data Single-Packaged Products with Energy -Saving Features and PuronR

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. Low

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial

More information

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons Product Data 50GS Single-Packaged Electric Cooling Units 1-1/2 to 5 Nominal Tons UNIT 50GS Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant Product Data Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons Single-Packaged Products with Energy-Saving Features and

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron Performancet 13 SEER Single---Packaged HYBRID HEATr Dual Fuel System with Puronr (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 024---060) Product Data C99088 Fig. 1 - Unit Single-Packaged

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

Product Data. Fig. 1 - Unit 48XL -A

Product Data. Fig. 1 - Unit 48XL -A 48XL---A Infinity 15 SEER Single---Packaged Air Conditioner and Gas Furnace with Puron (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 48XL -A A09032

More information

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons Product Data 50SX High Efficiency Single-Packaged Cooling Units 2 to 5 Nominal Tons 50SX High Efficiency, Single-Packaged Cooling Unit for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50GL Single-Package Products with Energy-Saving Features and Puron refrigerant. Low Sound

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits

50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits Product Data 50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant 7 to 14 kw (2 to 4 Nominal Tons) UNIT 50GL (50HZ) Single-Packaged Products with Energy-Saving Features

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons Product Data 50ZP Single-Package Air Conditioners 2 to 5 Tons UNIT 50ZP The 50ZP unit is a packaged air conditioner for manufactured housing, residential, and light commercial applications. The 50ZP unit

More information

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp. PHE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE HEAT PUMP UNIT - 13 & 15 Ton REFRIGERATION CIRCUIT Single reciprocating semi -hermetic compressor on all 13 ton units. Dual semi -hermetic compressors

More information

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES FACTORY- ASSEMBLED PACKAGE is a compact, fully self-contained, electric cooling unit with horizontal supply and return ducts. The PA1Z units are available in a variety of standard cooling sizes with voltage

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Product Data. Features/Benefits

Product Data. Features/Benefits PERFORMANCE 13 (N) SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron

More information

Product Data. Unit 574D

Product Data. Unit 574D SINGLE -PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R -410A) REFRIGERANT SINGLE- AND 3 -PHASE UNITS 1-1/2 to 5 NOM TONS (SIZES 018-060) Product Data Single-Packaged Products with Energy -Saving

More information

Model 574B Sizes

Model 574B Sizes SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 574B Sizes 024-060 2 to 5 Nominal Tons Low NOx Models Available UNIT 574B Single-Packaged Rooftop Products with Energy-Saving Features and Puron

More information

Product Data. Features/Benefits

Product Data. Features/Benefits , N 3-PHASE SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Rooftop Products with Energy-Saving Features and

More information

Product Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons

Product Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons Product Data Convertible duct configuration Unit is designed for easy use in either downflow or horizontal

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically

More information

A 14 SEER Heat Pump with R---410A Refrigerant Series

A 14 SEER Heat Pump with R---410A Refrigerant Series MODEL NUMBER NOMENCLATURE PH14 N B 018 00G B A 14 SEER Heat Pump with R---410A Refrigerant Series Electrical Supply N=208/230---1 P=208/230---3 E=460/3 B R---410A Nominal Capacity 018 1 1/2Tons 024 2Tons

More information

Model 583A Sizes

Model 583A Sizes SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 583A Sizes 024-060 2 to 5 Nominal Tons UNIT 583A Single-Packaged Rooftop Products with Energy-Saving Features. Direct Spark Ignition Low Sound Levels

More information

ASHRAE 90.1 EFFICIENCY PACKAGE GAS / ELECTRIC UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE GAS / ELECTRIC UNIT MBtuh PGE Product Specification ASHRAE 90.1 EFFICIENCY PACKAGE GAS / ELECTRIC UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide

More information

Product Data PY3P SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R-22 REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES ) 1 & 3 PHASE

Product Data PY3P SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R-22 REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES ) 1 & 3 PHASE SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R- REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES 024-060) 1 & 3 PHASE Product Data Convertible duct configuration Unit is designed for easy use in either

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION Bryant Air Conditioning Model 581A COMMERCIAL SINGLE PACKAGE ROOFTOP Sizes 155-240 GAS HEATING/ELECTRIC COOLING UNITS 13 to 20 Tons Model 581A155,180 Model 581A240 DESCRIPTION The 581A gas heating/electric

More information

Model 542F Size 180 COMMERCIAL ROOFTOP PACKAGED HEAT PUMP. Bryant Air Conditioning. Form No. PDS 542F.180.2B. 15 Tons DESCRIPTION

Model 542F Size 180 COMMERCIAL ROOFTOP PACKAGED HEAT PUMP. Bryant Air Conditioning. Form No. PDS 542F.180.2B. 15 Tons DESCRIPTION Bryant Air Conditioning COMMERCIAL ROOFTOP PACKAGED HEAT PUMP Model 542F Size 180 15 Tons MODEL 542F DESCRIPTION Model 542F is a high-efficiency, single-package heat pump that has an energy efficiency

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg) FCM4X Product Specifications FAN COILS WITH OBSERVERt COMMUNICATING CONTROL ALL MODELS S 2, 3, 4, and 5 Tons S Multi- position installation S Communicating, self configuring when used with Observer Communicating

More information

Advanced Product Data

Advanced Product Data 48PD and 50PD-05, 06 Displacement Ventilation or Single-Zone Variable Airflow Rooftop Units Single Package, Electric Cooling, Gas or Optional Electric Heating with PURON (R-410A) Refrigerant and COMFORTLink

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS. Performancet 16 2 --- Stage Heat Pump with Puronr Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with Puron r refrigerant provide a collection of features

More information

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons Product Data 50LJQ Single-Package Rooftop Heat Pump Units Nominal 3 to 10 Tons Single-Package Rooftop Heat Pump Units with the following Standard Features: 2-in. return-air filters Acutrol refrigerant

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCD

More information

Product Data. Features/Benefits. 50BYN Single-Package Air Cooled Vertical Packaged Units. 5to20Tons

Product Data. Features/Benefits. 50BYN Single-Package Air Cooled Vertical Packaged Units. 5to20Tons Product Data 50BYN Single-Package Air Cooled Vertical Packaged Units 5to20Tons The 50BYN units are single-package cooling units with integral air-cooled condensers designed for indoor installations. They

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product

More information

Product Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons Product Data 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units 2 to 5 Nominal Tons UNIT 48GX (Shown with Accessory Wire Grille) Single-Package Rooftop Products with Energy-Saving Features. Direct

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information