Reverse Engineering of a Household Fan. UEET101 Section 1 Group 1 Final Proposal Draft

Size: px
Start display at page:

Download "Reverse Engineering of a Household Fan. UEET101 Section 1 Group 1 Final Proposal Draft"

Transcription

1 Abstract Reverse Engineering of a Household Fan UEET101 Section 1 Group 1 Final Proposal Draft Justin Abraham Jonathan Abramson Matt Allen Byron Anderson Daniel Baffin Matt Waterman (Group Leader) Group 1 dissects and analyzes a typical, modern household fan to determine how electrical, mechanical, and industrial engineering methods apply to the design, construction, and every day function of the product. The fan's construction is reverseengineered in order to gain insights into how it was constructed and how it might be improved. Chapter 1 - Introduction The typical fan found in homes today is likely to be much more complex than fans of the past. Low cost microcontrollers and manufacturing techniques has led to significant innovation in products that might not have changed significantly for decades. The Holmes fan analyzed by Group 1 has many novel features that easily demonstrate aspects of mechanical, electrical, and industrial engineering. Priced at approximately $50, the fan is considerably more expensive than traditional fans, but this cost is a reflection of the fan's features. The fan is modern, lightweight, compact, and includes many useful features such as a sleep timer, oscillator, three speeds, and a remote control. Since it comes with a three-year warranty, the fan must be constructed to be reliable enough to last longer than three years in order to reduce the cost spent on repairing or replacing defective fans. Chapter 2 - Mechanical Engineering There are several mechanical components at work on this fan, the first being the motors. The main motor is located on the rear of the unit and drives a shaft, turning the actual fan blades. A second, smaller motor, powers the unique oscillation device. Both motors mount to portions of the fan's frame that must be stiff enough to withstand the torque. Gears in the the motor assembly for the oscillation device allow the device to spin slowly and consistently

2 with the small motor. The motors are the heaviest components of the fan and are mounted towards the center of the fan's height. The fan must be constructed such that the weight is balanced so the fan will not tip over during normal use. Portions of the base of the fan sweep backward to provide added stability. Not only did mechanical engineers ensure that the enclosure is well-balanced, they also designed an attractive and very functional enclosure. For instance, if the fan does tip over onto the rear, the enclosure is constructed such that airflow will not be restricted enough to prevent air from flowing through the fan and cooling the motor. This same aspect of the design allows the fan to be placed closer to walls and other objects than traditional fans. The efficiency of the mechanical parts is important. A mechanical engineer should calculate what degree the fan blades should be to maximize movement of air and minimize noise at speeds that will be useful to the consumer. Complex analysis of the fluid dynamics of air through the fan may have been performed during the design of the fan to optimize airflow. The motors must be powerful enough to move the blades and the oscillator for the life of the fan. The oscillator on the front of the fan also serves as a grill to prevent objects from hitting the fan blades and must be constructed to be strong enough for this task. Quality is very important when designing products and the mechanical components of the fan must be designed to last through the life of the fan and will require little or no maintenance. Chapter 3 - Electrical Engineering Aspects Electrical engineering is perhaps the most obvious area where this particular fan stands apart from the more common models. Instead of having only a switch that, at best, controls several speed levels, the electrical operations of the fan are managed by a microcontroller. Several buttons on the front of the fan and on the remote provide user input to the microcontroller and several LEDs and a piezo beeper provide feedback. Many of the fan's unique features rely on the mictrocontroller, including the sleep timer, breeze modes, speed control, oscillation, and the ability to decode digital signals sent via the infra-red remote control. The fan is powered by 120v AC current and is rated to draw 0.4 amps. It has an internal circuit breaker for added safety in the event that the fan malfunctions and draws too much current. A single printed circuit board contains all of the circuitry, including a small transformer to power the electronics. The large AC motor spins the fan blade element at one of three speeds. Depending on the breeze mode, the motor will either spin constantly at a selected speed or, if a breeze mode is selected, the fan will alternate between higher and lower speeds automatically to approximate a

3 natural breeze. The second, smaller AC motor spins in either direction at a single speed to turn an array of fins on the front of the fan which cause air to flow in varying directions as it rotates. The main source of current draw is from the main motor of the fan. When plugged in, the fan will draw a minimal amount of power in order to run the microcontroller in standby mode. This allows for the fan to be powered on by pressing a button on the front or via remote control. The 120v AC motor that powers the oscillator is rated to draw no more than amps and so represents a minimal impact on the total current drawn. The LED indicators on the front of the fan use negligible power. The total amount of current used will vary widely depending on whether or not the oscillator is in use and, in particular, which speeds or breeze modes are selected. When operated at the second power level (out of three) with the oscillator rotating clockwise and no breeze mode selected, the fan was measured to draw approximately 0.28 amps. This is significantly less than the rated 0.4 amps and is probably more typical of the fan in average use. Chapter 4 - Industrial Engineering Careful implementation of industrial engineering practices is necessary in order to make the fan competitively priced and reliable. In order to minimize cost, the fan is constructed almost entirely of plastic. The separate pieces are assembled easily, making for a fairly cheap product that is durable, easy to use, and marketable. The motor assembly that powers the oscillation device includes gears already built into the stamped-metal housing of the assembly. This component is dropped into place and secured with screws. Altogether, the fan only uses three separate sizes of screws. Further simplifying the assembly process, most of the electrical connections are made with crimp connectors. The wires connecting the PCB to the main motor are the only connections that must be soldered during the final assembly. The total cost of the individual components and assembly of the fan is estimated to be less than $20. Due to its innovative features and construction, the design of the fan is likely to have been uncharacteristically intensive. The shape of the fan's complex enclosure would have required the use of 3D computer aided drafting and may have involved significant artistic consultation. The effective and quiet operation of the fan blades indicates that costly computer-based analysis of fluid dynamics through the fan might have been performed. Furthermore, the microcontroller which the fan relies upon so heavily for its features would have required microcontroller programmers to create the software in use. The fan's remote control is likely an off-the-shelf model provided by a third party at minimal cost.

4 There are too many variables involved in calculating the profit margin of the fan to be determined through reverse-engineering. Other variables beyond those mentioned above include the packaging, cost of shipping to retailers, the costs of the retail process in general, and many others. The manufacturer must also me mindful of the potential costs of warranty work for fans that malfunction within the three-year warranty period. All of these factors and the total number of fans sold contribute to the profitability of the $50 fan. Chapter 5 - Environmental Impact Calculating the environmental impact of the fan involves many potential variables. Holmes does not indicate that the fan has been constructed of recycled materials. The significant use of plastic in the fan means that a considerable amount of petroleum is consumed in order to produce the fan. Reviews posted on Amazon.com by individuals who have purchased this fan indicate that it may not be very reliable. Since most consumers do not recycle this type of appliance, it is likely that these fans will, since they will likely fail within three years, contribute to landfill waste. Their plastic and metal construction means that the fans will not decompose. On top of this, the fan requires electricity to operate. Due to the nature of electrical power generation in the United States, this means that the fan will contribute to the production of greenhouse gases. For example, based on statistics provided for electrical power generation in the state of Illinois, if the fan is used four hours a day and 180 days in a year and draws its maximum current rating, it will contribute about 20kg of carbon dioxide, 307 grams of nitrous oxide, and 140 grams of methane yearly. However, this impact is not atypical of this type of product and is largely unavoidable. Conclusion The Holmes fan is an exciting piece of technology that uses modern technology to improve on an old design. Careful electrical, mechanical, and industrial engineering create a product that satisfies the requirements of most customers in a package that is producible and profitable. Still, the fan could stand to be improved. In order to reduce the environmental impact, the fan could be produced out of recycled materials. While the fan is quiet, it could be made even quieter by increasing the diamter of the fan blades. The breeze modes have been found to be particularly useless since the fan can spin at only three speeds and the breeze modes switch quickly between them. If the fan was redesigned to provide infinite speeds, the breeze modes could be made more desirable. The sleep

5 timer, while it is very useful, is difficult to set since the timer must be selected using one button to scroll through the available countdown times. A second button could be added to scroll backwards through the times or the timer could be redigned to incorporate seven-segment LED displays and digital selection for custom countdown times. These improvements, however, could potentially add to the cost of producing the fan. With an already relatively high price tag, this would likely reduce sales. The reverseengineering has shown the fan to be designed and constructed very intelligently and with minimal room for improvement. References Homing In On Fan-Noise Sources In Induction Motors gnvcm100000f932a8c0 A Calculated Loss: How to Reduce Your Global Warming Emissions Voluntary Reporting of Greenhouse Gases Program Amazon.com - Holmes-HAPF622R-Blizzard-Remote-Control Control/dp/B B4/ref=pd_bbs_sr_1?ie=UTF8&s=homegarden&qid= &sr=8-1

CHOOSING A COOLING SYSTEM

CHOOSING A COOLING SYSTEM CHOOSING A COOLING SYSTEM Do you dread the thought of enduring another sweltering summer of sleepless nights? Can you no longer bear living in a hot box and want to install a cooling system but don t know

More information

The Basics of Package/Device Cooling

The Basics of Package/Device Cooling The Basics of Package/Device Cooling Various cooling methods are available for keeping electronic devices within their operating temperature specifications. Cooling Consumer Products In the case of consumer

More information

Responsible Care Product Stewardship for Refrigerants

Responsible Care Product Stewardship for Refrigerants 1 ABSTRACT Responsible Care Product Stewardship for Refrigerants Christoph Meurer; Ewald Preisegger Solvay Fluor und Derivate GmbH Hans-Böckler-Allee 20 30161 Hannover Germany Product stewardship summarizes

More information

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment Laird Thermal Systems Application Note Bi-directional Microcontrollers Monitor and Protect Medical Equipment Contents Overview...3 Thermal Management Technologies...3 Design Example...3 Thermoelectric

More information

Garbage Disposal. The University of Akron. Madison Popa Tyler Miller

Garbage Disposal. The University of Akron. Madison Popa Tyler Miller The University of Akron IdeaExchange@UAkron Honors Research Projects The Dr. Gary B. and Pamela S. Williams Honors College Spring 2018 Garbage Disposal Madison Popa mrp68@zips.uakron.edu Tyler Miller tmm139@zips.uakron.edu

More information

REVERSING DRUM MIXER

REVERSING DRUM MIXER REVERSING DRUM MIXER the leader in mixer design a new spin on mixers it is only sand, rock, water and cement until you mix it Without proper mixing, concrete will fail to achieve its desired properties.

More information

Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills

Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills Author: Stéphane BERTRAND CATERPILLAR Europe, Africa and the Middle East. Industrial and Waste applications specialist

More information

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool Air Conditioning Product Brochure 2015/2016 Classic Series Hi-Wall Split Systems Everyday Cool 3 Everyday Innovation We design with you in mind. You ll find that Haier Air Conditioning units are quiet,

More information

QUINCY QGS SERIES hp

QUINCY QGS SERIES hp QUINCY QGS SERIES Rotary screw air compressors 5-100 hp QGS 5-30 HP Belt Drive rotary screw technology for every application Quincy understands the critical nature of your compressed air system to maintain

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Trane Family of Terminal Products

Trane Family of Terminal Products Trane Family of Terminal Products It s time to take another look at terminal. As your partner, Trane understands it takes more than a concept to design an effective HVAC system. Between cost and code compliance

More information

Va c S t a r V a c S t a r N e o. More Performance. Less Water. Less Energy.

Va c S t a r V a c S t a r N e o. More Performance. Less Water. Less Energy. Va c S t a r V a c S t a r N e o & More Performance. Less Water. Less Energy. Powering Your Practice VacStar liquid-ring vacuums have been trusted by dentists since 1986 and still deliver best-in-class

More information

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency Haiye Lou TurboMoni Applied Dynamics Lab Abstract It is often happened, when a project

More information

Guidelines for Optimizing Drying and Blow-Off Operations

Guidelines for Optimizing Drying and Blow-Off Operations Experts in Technology Nozzles Control Analysis Fabrication Guidelines for Optimizing Drying and Blow-Off Operations Changing your approach can slash operating costs and increase efficiency Jon Barber,

More information

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL AOYUE INT 968A+ Deluxe Repairing System INSTRUCTION MANUAL Thank you for purchasing Aoyue INT 968A+ Repairing System. It is important to read the manual before using the equipment. Please keep manual in

More information

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable Smart Smart IR model (check applicable) is recognized as serviceable Service instruction SALES DATE MANUFACTURED ON (DATE): SOLD APPROVAL MARK SMART-EN-04 BLAUBERG Company is happy to offer your attention

More information

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT INTRODUCTION Top energy-efficient performance Advantages of Flygt top-entry agitators Rising to the mixing challenge All mixing applications require varying

More information

10 tips for getting more reliability from your air-conditioning system [reliability]

10 tips for getting more reliability from your air-conditioning system [reliability] 10 tips for getting more reliability from your air-conditioning system [reliability] A guide for installers, specifiers, contractors and architects February 2010 10 tips for getting more reliability from

More information

DUCTLESS ROOM AIR CONDITIONERS

DUCTLESS ROOM AIR CONDITIONERS DUCTLESS ROOM AIR CONDITIONERS Breeze THE EXPERTS IN ROOM AIR CONDITIONING Breeze The NEW look of quiet, energy efficient room cooling. Attractive wall mount unit is compact and lightweight. It mounts

More information

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater MIRCEA NICOARĂ mircea.nicoara@mec.upt.ro AUREL RĂDUłĂ aurel.raduta@mec.upt.ro LAURENłIU ROLAND CUCURUZ roland.cucuruz@mec.upt.ro COSMIN

More information

A Revolution In Lead-Free Hand Soldering By Ed Zamborsky - OK International Eastern Regional Sales Manager

A Revolution In Lead-Free Hand Soldering By Ed Zamborsky - OK International Eastern Regional Sales Manager A Revolution In Lead-Free Hand Soldering By Ed Zamborsky - OK International Eastern Regional Sales Manager By the time a printed circuit board is ready for the final manual soldering of its odd-form components,

More information

TFD-1 Installation & User s Guide

TFD-1 Installation & User s Guide TFD-1 Installation & User s Guide TABLE OF CONTENTS CHAPTER 1 - INTRODUCTION... 4 1.1 GENERAL...4 1.2 DESCRIPTION...4 CHAPTER 2 - INSTALLATION... 5 2.1 UNPACKING...5 2.2 MOUNTING...5 2.3 SWITCH SETTINGS...6

More information

HW-17 Record Cleaning Machine Setup and Instruction Manual

HW-17 Record Cleaning Machine Setup and Instruction Manual HW-17 Record Cleaning Machine Setup and Instruction Manual VPI Industries, Inc., 77 Cliffwood Ave. #3B, Cliffwood, NJ 07721 Phone: 732-583-6895, Email: Sales@vpiindustries.com http://www.vpiindustries.com

More information

Engineers look for improvement. 30 years ago, we began developing cyclone vacuum technology. More recently, hand dryers using high-pressure sheets of

Engineers look for improvement. 30 years ago, we began developing cyclone vacuum technology. More recently, hand dryers using high-pressure sheets of Engineers look for improvement. 30 years ago, we began developing cyclone vacuum technology. More recently, hand dryers using high-pressure sheets of air instead of heat. Now our attention has turned to

More information

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans WHITE PAPER: Cooling Industrial Enclosures with Filter Fans Cooling Industrial Enclosures With Filter Fans Introduction As electronic components get smaller and more densely packed into enclosures, systems

More information

Rotary Screw Vacuum Systems

Rotary Screw Vacuum Systems Rotary Screw Vacuum Systems 4-150 kw 5-200 Horsepower Reliable Quiet Smooth, Pulse-free Operation Energy Efficient Sullair Capabilities www.drgair.com Sullair Leadership Since 1965, Sullair has been recognized

More information

Gas Furnaces Two-Stage, Variable- Speed with iseer

Gas Furnaces Two-Stage, Variable- Speed with iseer Gas Furnaces Two-Stage, Variable- Speed with iseer Tough. Smart. Tappan. TM The Military Wanted Tank-Tough. They Got It. Tappan s reputation for tough, durable products was, in the beginning, cast in iron.

More information

G Series Inverter Split Systems

G Series Inverter Split Systems G Series Inverter Split Systems Rinnai Creating comfort in the home. Australians have been enjoying the comfort, convenience and reliability of Rinnai household appliances in their homes for over 40 years.

More information

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS WALL- MOUNTED HEAT PUMP Up to 24.5 SEER / Up to 12.5 HSPF / 15.3 EER INVERTER, VARIABLE-SPEED COMPRESSOR Today, the air is perfect. Perfect temperature.

More information

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations Trailer Refrigeration Multi Temperature Truck Refrigeration Single and Multi Temperature Lowest environmental impact

More information

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES Proceedings of the 2014 10 th International Pipeline Conference IPC2014 September 29-October 3, 2014, Calgary, Alberta, Canada IPC2014-33387 SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES

More information

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES Ola, Gustafsson M.Sc. a *, Lennart Rolfsman M.Sc. a, Sara Jensen B.Sc. a, Markus Lindahl M.Sc. a, a SP Technical

More information

dissipation: air conditioning, compressed air and heat exchangers. Air conditioning was

dissipation: air conditioning, compressed air and heat exchangers. Air conditioning was Heat Exchangers vs. Air Conditioning: The Optimal Choice for Cooling Electronics Written by Kimberley Dawn, chief executive officer, Noren Products Exclusively for Process Cooling Submitted by Trade Press

More information

ES-6 S-energy Encapsulated Rotary Screw Air Compressors

ES-6 S-energy Encapsulated Rotary Screw Air Compressors ES-6 S-energy Encapsulated Rotary Screw Air Compressors 4-7 kw 5-10 Horsepower Simple Compact Reliable Lower Maintenance Costs Quiet Sullair Capabilities Sullair Leadership Since 1965, Sullair has been

More information

Overview SENSING AND CONTROL. Part Innovation. Part Engineering. Total Solutions.

Overview SENSING AND CONTROL. Part Innovation. Part Engineering. Total Solutions. Overview SENSING AND CONTROL Part Innovation. Part Engineering. Total Solutions. Engineered Excellence For innovation that s well apart, there s only Honeywell Sensing and Control (S&C). With more than

More information

The fastest, most hygienic hand dryers.

The fastest, most hygienic hand dryers. The fastest, most hygienic hand dryers. It s been seven years in the making but we ve now achieved something quite revolutionary in motor design one of the world s smallest fullyintegrated 1400W motors.

More information

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings 86 C freezers New Benchmark New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings 2 World-class service. NEW HEF Models For over 50 years, New Brunswick lab products

More information

AMERICA'S HEATING & COOLING CHOICE. Fans 2015 CATALOG

AMERICA'S HEATING & COOLING CHOICE. Fans 2015 CATALOG AMERICA'S HEATING & COOLING CHOICE Fans 2015 CATALOG COMFORT ZONE ENVIRONMENT PRODUCTS Personal Fans Personal fans are the perfect choice for small spaces. These fans are quiet and compact yet have powerful

More information

Sustainability begins with our people. On the road to a more sustainable world

Sustainability begins with our people. On the road to a more sustainable world The very green book Sustainability begins with our people On the road to a more sustainable world Sustainability requires everyone s commitment. By working together, harnessing our ideas and creativity,

More information

Blades cause buffeting. The blades on conventional fans cause unpleasant buffeting because they chop the air before it hits you.

Blades cause buffeting. The blades on conventional fans cause unpleasant buffeting because they chop the air before it hits you. Engineers look for improvement. 30 years ago, we began developing cyclone vacuum technology. More recently, hand dryers using high-pressure sheets of air instead of heat. Now our attention has turned to

More information

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY DESIGNER RANGE W A L L M O U N T E D SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu is a leading supplier

More information

Energy Efficiency Practices for the Low- Income Population

Energy Efficiency Practices for the Low- Income Population Energy Efficiency Practices for the Low- Income Population Donald Fournier Managing Director SEDAC University of Illinois Residential Energy American homes use almost 25% of the energy consumed in the

More information

F-Series Tower Drying

F-Series Tower Drying Tower Dryers F-Series Tower Drying F-Series Tower Drying We define grain drying. We define grain drying. FFI Features Gravity inlet does not require leveling auger, reducing the number of moving parts.

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Cast Line Heaters The Benefits of This Space Saving Electric Heater WHITE PAPER Cast Line Heaters The Benefits of This Space Saving Electric Heater Introduction Cast line heaters, or cast-in heaters, offer an alternative to the more common inline process heaters that have

More information

Performance Climate Changer Next generation air handler from Trane

Performance Climate Changer Next generation air handler from Trane Performance Climate Changer Next generation air handler from Trane Trane Performance Climate Changer Air Handler Two-inch, R-13 foam-injected panels with mid-span, internal thermal breaks and standard

More information

M3 Design Product Teardown Asko Dishwasher

M3 Design Product Teardown Asko Dishwasher 11 Jun, 2010 Why do the product teardowns? M3 Design Product Teardown Asko Dishwasher Part of the product development process is to apply knowledge gained from prior experience during the concept development

More information

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc. USER S MANUAL ALARM HI F2 COOL / HEAT ALARM LO DIFF on off PERIOD TIMER L IMIT reduc. 9 per day 88 ADJUST Varifan + Although the manufacturer has made every effort to ensure the accuracy of the information

More information

DZ20VC HEAT PUMP HIGH-EFFICIENCY, INVERTER TECHNOLOGY UP TO 21 SEER UP TO 10 HSPF VARIABLE-SPEED COMFORTNET COMPATIBLE COMFORT FOR LIFE

DZ20VC HEAT PUMP HIGH-EFFICIENCY, INVERTER TECHNOLOGY UP TO 21 SEER UP TO 10 HSPF VARIABLE-SPEED COMFORTNET COMPATIBLE COMFORT FOR LIFE DZ20VC HEAT PUMP HIGH-EFFICIENCY, INVERTER TECHNOLOGY UP TO 21 SEER UP TO 10 HSPF VARIABLE-SPEED COMFORTNET COMPATIBLE COMFORT FOR LIFE www.daikincomfort.com "I'm a Daikin Comfort Pro" Those five simple

More information

Slimline, Energy Saving & Smart. It's the game changer!

Slimline, Energy Saving & Smart. It's the game changer! Innovators of the award-winning Vortex EcoSmart, the world s first hand dryer to achieve a Guinness World Records title, and winner of the Energy & Environmental Product Service award, SAVORTEX now introduces

More information

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL temperature / static pressure DIFF Opn Clo ALARM HI F2 DELAY ALARM LO OPEN DELAY CLOSE ADJUST Varifan + CPS-1 CPS-1 Although the manufacturer has made every

More information

Frequently Asked Questions Refuse (Garbage) Rates, July 1, 2015

Frequently Asked Questions Refuse (Garbage) Rates, July 1, 2015 Frequently Asked Questions Refuse (Garbage) Rates, July 1, 2015 Why are residential Refuse rate increases needed? The single-family residential refuse service includes collection, processing and disposal

More information

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner. Register your product online at www.broan.ca/register.asp. ZB90C ZB0C X Multi-Speed Ventilation Fan INSTALLATION GUIDE Easy

More information

Service Manual for / How to Remove the Cover

Service Manual for / How to Remove the Cover Service Manual for 2903-28 / 2904-28 How to Remove the Cover Cover Specification Cast Iron White Porcelain 2903-28, Sensor Activation (replacement P/N: P15-420) 2904-28, Push Button Activation (replacement

More information

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Fuel for thought Choosing the right heating system for

More information

MORE VALUE TO YOUR WELL-BEING

MORE VALUE TO YOUR WELL-BEING Green Comfort, Design and Energy Saving. FCL and FCLI Inverter MORE VALUE TO YOUR ELL-BEING Cassette fan coils Cassette fan coils FCL On-Off / FCLI greater comfort, less consumption The future is Inverter

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 CFC REFRIGERANTS Since the 1930s, chlorofluorocarbons (CFCs) have been widely used as foam blowing agents, aerosols and especially refrigerants due to their pre-eminent properties

More information

ECS 5M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

ECS 5M USER S MANUAL ENVIRONMENT CONTROL SYSTEM ECS 5M USER S MANUAL ENVIRONMENT CONTROL SYSTEM 5 stages computer compatible RH RH 1 2 3 4 5 ALARM ALARM LO HI F2 12 11 10 1 MOTOR MIN SPEED 2 on off 3 TIMER FAN 1 DIFF + Varifan LIMIT HEAT FAN 5 reduc.

More information

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc Important Considerations When Selecting a Fan for Forced Air Cooling By: Jeff Smoot, CUI Inc Designing an appropriate thermal management solution requires a systemic approach; each component on a circuit

More information

Instruction Leaflet 99.97% TRUE HEPA AIR PURIFIER. pure indoor living MODEL: BAP925-CN. Replacement filters: A1230H and A1260C

Instruction Leaflet 99.97% TRUE HEPA AIR PURIFIER. pure indoor living MODEL: BAP925-CN. Replacement filters: A1230H and A1260C pure indoor living 99.97% TRUE HEPA AIR PURIFIER MODEL: BAP925-CN Instruction Leaflet Read instructions before operating. Retain for future reference. Questions? Comments? Call 1-800-253-2764 in North

More information

ECS-2M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

ECS-2M USER S MANUAL ENVIRONMENT CONTROL SYSTEM ECS-2M USER S MANUAL ENVIRONMENT CONTROL SYSTEM 2 stages computer compatible RH RH 1 2 ALARM ALARM HI F2 12 11 LO 10 1 DIFF 2 3 MOTOR MIN SPEED HUMIDITY FAN 1 + LIMIT 9 reduc. per day 8 rel 7 6 5 4 on

More information

Remote Controller. <Open the front cover> <ARC452A4>

Remote Controller. <Open the front cover> <ARC452A4> Remote Controller 1 2 9 10 3 4 5 6 7 8 13 14 15 17 11 12 16 18 1. Signal transmitter: It sends signals to the indoor unit. 2. Display: It displays the current settings.

More information

Who we are and what we do. The story of the world s leading manufacturer of axial impellers

Who we are and what we do. The story of the world s leading manufacturer of axial impellers Who we are and what we do The story of the world s leading manufacturer of axial impellers OUR COMPANY 02//03 04//05 06//07 OUR COMPANY OUR MARKETS OUR TECHNICAL SUPPORT We know that to you, the impeller

More information

GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION

GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION WATER SOFTENER: The Water Softener requires a 120VAC 2 AMP electrical service and the Water lines in and out need to be sized to the Softener.

More information

AP Air Ion Counter Instructions

AP Air Ion Counter Instructions AP Air Ion Counter Instructions Standard 2 million ions/cm 3 version- The 6 m long ground cord should be used to connect the meter to earth ground for most types of measurements - - especially if you are

More information

HEAT PUMP HIGH-EFFICIENCY SCROLL COMPRESSOR UP TO 15 SEER, UP TO 9.0 HSPF SINGLE SPEED

HEAT PUMP HIGH-EFFICIENCY SCROLL COMPRESSOR UP TO 15 SEER, UP TO 9.0 HSPF SINGLE SPEED DZ14SA HEAT PUMP HIGH-EFFICIENCY SCROLL COMPRESSOR UP TO 15 SEER, UP TO 9.0 HSPF SINGLE SPEED COMFORT FOR LIFE www.daikincomfort.com "I'm a Daikin Comfort Pro" Those five simple words can offer you comfort

More information

INTELLIGENT SUCTION. Upgrade-AtoB

INTELLIGENT SUCTION.  Upgrade-AtoB is a variable speed suction system, that automatically adapts to the clinic s requirements; lift a suction tip and the unit responds by increasing its speed, hang up the tip and the Turbo Smart slows down.

More information

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

ETI-Z, GART-ZE/ZEI Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range 3 "ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range YOSHIE TOGANO *1 JUN MIYAMOTO *1 YOSHIE KANKI *1 KAZUMI SHIMIZU *1 TAKAAKI MIURA *2 YASUSHI HASEGAWA *3 In

More information

Mixing Technologies Solutions for Flue Gas Desulfurization

Mixing Technologies Solutions for Flue Gas Desulfurization Mixing Technologies Solutions for Flue Gas Desulfurization Reliable FGD Mixing Solutions The Mixing Technologies Group of NOV is a leading supplier of mixing solutions and products for Flue Gas Desulfurization

More information

An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction

An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction A White Paper for the Enercon Venturi Condensate Removal (EVCR)

More information

Instruction manual. Please keep safe for future reference

Instruction manual. Please keep safe for future reference 16in / 40cm Eco Pedestal Fan with 30W DC motor, Digital Display & Remote Control Model: SFDC-40101RC WARNING: Keep Batteries Out of Reach of Children 1. Swallowing may lead to serious injury in as little

More information

Detecting Leaks and Reverse Flow with 60 Series Endpoints

Detecting Leaks and Reverse Flow with 60 Series Endpoints Itron White Paper 60 Series Endpoints Detecting Leaks and Reverse Flow with 60 Series Endpoints Peter Sanburn / Allen Rogers Itron Product Marketing 2008, Itron Inc. All rights reserved. 1 Introduction

More information

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating Gas-Fired Condensing Boilers A Green Start To Space & Water Heating Residential space and water heating boiler solutions with up to 98.7% efficiency and 57.2 to 151.6 MBH inputs. 1 New! Bosch residential

More information

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

AXIAL FAN User s manual. Quiet-dMEV 100 DC. AXIAL FAN User s manual Quiet-dMEV 100 DC www.ventilation-system.com CONTENTS Delivery set... 6 Brief description... 6 Operating guidelines... 6 Designation key... 7 Installation and set-up... 7 Fan options...

More information

COIN OPERATED ELECTRONIC QUANTUM GOLD WASHERS

COIN OPERATED ELECTRONIC QUANTUM GOLD WASHERS COIN OPERATED ELECTRONIC QUANTUM GOLD WASHERS SCN020-20lb/8.16kg Washer SCN030-30lb/13.6kg Washer SCN040-40lb/18kg Washer SCN060-60lb/27kg Washer SCN080-80lb/36.3kg Washer THE BEST IN CLASS JUST GOT BETTER

More information

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION Pacific HVAC Engineering is able to offer a complete solution in car park ventilation at a competitive price with in house developed

More information

1.1. SCOPE OF THE WORK:

1.1. SCOPE OF THE WORK: Chapter 1: Introduction 1 1. INTRODUCTION 1.1. SCOPE OF THE WORK: Multi-stage refrigeration systems are an area of growing industrial importance in large plants. These systems are known to be large power

More information

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries International Reactor Bulletin 1100 Corporation Standard and Custom Reactors for the Chemical Process Industries 2 International Reactor Corporation 521 Kiser Street Dayton, Ohio 45404-1641 Phone: 937-224-4444

More information

Design of Microwave Anti-theft Alarm Based on Microcontroller

Design of Microwave Anti-theft Alarm Based on Microcontroller Design of Microwave Anti-theft Alarm Based on Microcontroller Hanhong Tan Guangdong University of Science & Technology,Dongguan,523083, China Abstract At present, most households use safety gates and install

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

2. Pictographs 2.1 Basic Operation

2. Pictographs 2.1 Basic Operation Pictographs 2. Pictographs 2.1 Basic Operation ON / OFF button Operation starts and stops every time you press the button. MODE selector button Operation mode changes every time you press the button. H/P

More information

Breeze A revolution in room cooling.

Breeze A revolution in room cooling. DUCTLESS AIR CONDITIONERS WALL-MOUNTED Heat PumpS Breeze A revolution in room cooling. EXTREMELY QUIET SUPER HIGH EFFICIENCY EASY INSTALLATION www.friedrich.com Enjoy the view! Installs high on the wall

More information

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH Zephyr 16 DC FAN WELCOME Thank you and congratulation for choosing an EcoAir DC Fan to help you improve the air quality within your home. Inside you will find many helpful tips on how to use and maintain

More information

Model: EF34. Owner's Guide & Installation Manual

Model: EF34. Owner's Guide & Installation Manual Owner's Guide & Installation Manual WARNING: Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in damage to property, serious

More information

The fastest to dry hands hygienically with HEPA filtered air.

The fastest to dry hands hygienically with HEPA filtered air. The fastest to dry hands hygienically with HEPA filtered air. Dyson Airblade hand dryers 01 02 Why do we put up with products that don t work properly? In 1907, paper towels were introduced to washrooms.

More information

Flexible and efficient: Close Climate Control for IT equipment

Flexible and efficient: Close Climate Control for IT equipment GEA Multi-DENCO Flexible and efficient: Close Climate Control for IT equipment engineering for a better world GEA Heat Exchangers GEA Multi-Denco at a glance: Multiple functions and applications High flexibility

More information

High-Efficiency Heat Exchangers

High-Efficiency Heat Exchangers High-Efficiency Heat Exchangers for All Your HVAC Applications World-leading Product Range of Residential, Commercial and District Energy Network Solutions Complete Range of High-Efficiency Plate Heat

More information

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than

More information

INTELLIGENT AXIAL FAN user's manual

INTELLIGENT AXIAL FAN user's manual ACCEPTANCE CERTIFICATE The fan is duly recognized as serviceable. ifan Approval mark Manufactured on (date) Sold (name and stamp of the trade company) INTELLIGENT AXIAL FAN user's manual model VENTS ifan

More information

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO Air Conditioning & Heating Multi-DENCO Multi-Denco» Precision Climate Control Promise Precision control is more than just an industry term, it is a promise. A promise we sustain using our extensive experience.

More information

Mixers and Flocculators. For Municipal Water Treatment

Mixers and Flocculators. For Municipal Water Treatment Mixers and Flocculators For Municipal Water Treatment Equipment for Enhanced Mixing and Flocculation We manufacture a wide range of mechanical mixers and flocculators designed to enhance the performance

More information

ADVANCING HVLS technology through controls and energy efficiency

ADVANCING HVLS technology through controls and energy efficiency WAVE HVLS FANS Kelley High Volume Low Speed fans are designed to provide an energy-efficient solution for large spaces. HVLS fans require much less energy than traditional HVAC systems, and provide year-round

More information

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS TM WALL-MOUNTED HEAT PUMP Up to 26.1 SEER / 11.0 HSPF / 15.8 EER INVERTER, VARIABLE-SPEED COMPRESSOR QUATERNITY Series TM Discreet wall-mounted unit

More information

ET4407. Life Cycle Assessment of Washing Machine. Student: David McNamara ID Number:

ET4407. Life Cycle Assessment of Washing Machine. Student: David McNamara ID Number: ET4407 Life Cycle Assessment of Washing Machine Student: David McNamara ID Number: 12061379 Table of Contents Introduction... 3 1.0 Methodological Approach... 4 1.1 Streamlined Life Cycle Assessment (LCA)...

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

TECHNICAL PUBLICATION

TECHNICAL PUBLICATION TECHNICAL PUBLICATION Title: A Common Sense Approach to Intelligent Completions Page 1/7 COPYRIGHT NOTATION: This paper is copyright material of PROMORE, A Core Laboratories Company. Publication rights

More information

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators PN: 89-3048 Evaporator EM-1 Our EM-1 ceiling mount air conditioning evaporator has been engineered for maximum serviceability and ease of installation in commercial and school buses. Because the drain

More information

OIL AND GAS INDUSTRY

OIL AND GAS INDUSTRY FIRED HEATER DESIGN This case study demonstrates the implementation of an API 560 fired heater compound component in Flownex. It also shows how Flownex has been used during the process design and preliminary

More information

ELECTRICAL APPLIANCES

ELECTRICAL APPLIANCES ELECTRICAL APPLIANCES The energy performance of many types of equipment which contribute to building energy use are regulated by MEPS (Minimum Energy Performance Standards) and energy rating labels. These

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information