Fan Heater SW02 Quiet fan heater for connection to water in small buildings
|
|
- Jason Floyd
- 5 years ago
- Views:
Transcription
1 heat model Heater Quiet fan heater for connection to water in small buildings Application is a compact fan heater with very low sound level designed for water connection. It is ideal for use where fan heaters are traditionally used such as in industrial buildings and warehouses, but also in environments with high demands on low sound levels, for example, stores and assembly halls. Comfort Frico's fan heaters are extremely quiet and quickly provide comfortable heating. The heater fan is equipped with an air director, which has individually adjustable louvres and directs the air as required. Operation and economy Frico's air fan heaters have a long life, providing fast and effective heating at a low cost. The air for can be controlled in three steps, which gives energy efficient put. Product specifications Very low sound level. Mounted using the enclosed bracket on the wall or ceiling. Intended to pump hot water up to +0 C in the standard design, but available for water temperatures up to +30 C in special designs. Supplied with air director with individually adjustable louvres that direct the air on one plane. Three fan speeds. Corrosion proof housing made of hot zincplate and powder enameled steel panels. Colour: RAL 906, NCS 0500 (white). Aluminium louvres. Design The fan heater has a classic clean design in white enamelled sheet steel.
2 Technical specifications heater Heat put* * Sound level* 3 Voltage Amperage Weight [W] [m 3 /h] [db(a)] [V] [A] [kg] 8-0 0,0/0, V~ 0,3 5 * ) Applicable at water temperature 80/60 C, surrounding temperature +5 C, fan min-max. * ) Applicable at fan min-max * 3 ) Applicable at fan min-max. Conditions: Distance to fan 5 m. Direction factor:. Equivalent absorption area: 00 m. Protection class: IP44. CE compliant. Dimensions 88 Outlet Inlet Mounting and connection Mounting The fan heater can be mounted on the wall for horizontal air in or on the ceiling for vertical air in. Installation of the heating coil Pipe connections can be made on either side of the fan heater. The heating coil has copper pipes with plain pipe connections, for solder or compression couplings. The bleed valve must be connected on the high point side of the unit. Bleed and drain valve not included with the unit. For correct inlet and let connection of the heating coil, see the dimension diagrams. Electrical installation The fan heater is intended for permanent installation. Design and specifications are subject to change with notice.
3 charts water Incoming / going water temperature 30/65 C Max 0,3 6,8 47 0,06 4, 5 0,05,9 54 0,05 Med 0,7 5, 49 0,06,6 54 0,05,8 56 0,04 Min 0,0,6 54 0,05 0,6 58 0,04 9,6 60 0,04 Incoming / going water temperature 90/70 C Max 0,3 5,7 44 0,9 3, 49 0,6,9 5 0,5 Med 0,7 4,3 46 0,8,0 5 0,5 0,9 53 0,3 Min 0,0,7 5 0,4 9,8 55 0, 8,9 57 0, Incoming / going water temperature 80/60 C Max 0,3 3,3 39 0,6 0,8 43 0,3 9,6 46 0, Med 0,7, 40 0,5 9,9 45 0, 8,8 47 0, Min 0,0 9,9 44 0, 8, 48 0,0 7, 49 0,09 Incoming / going water temperature 70/40 C Max 0,3 8,8 7 0,07 6,3 3 0,05 5,0 33 0,04 Med 0,7 8,0 8 0,06 5,8 3 0,05 4,6 34 0,04 Min 0,0 6,6 3 0,05 4,6 34 0,04 3,6 35 0,03 Incoming / going water temperature 60/40 C Max 0,3 8,5 6 0,0 6, 3 0,07 4,9 33 0,06 Med 0,7 7,7 7 0,09 5,5 3 0,07 4,4 34 0,05 Min 0,0 6,3 30 0,08 4,5 33 0,05 3,6 35 0,04 Incoming / going water temperature 60/30 C Max 0,3 6, 0 0,05 3,0 3 0,0,3 6 0,0 Med 0,7 5,5 0,04,9 4 0,0, 7 0,0 Min 0,0 4,4 0,04,5 5 0,0,9 8 0,0 Incoming / going water temperature 55/35 C Max 0,3 7, 3 0,09 4,8 8 0,06 3,5 9 0,04 Med 0,7 6,6 4 0,08 4,4 8 0,05 3, 30 0,04 Min 0,0 5,4 6 0,06 3,5 9 0,04,4 30 0,03
4 Pressure drop water pressure drop over water coil [m³/h] Pressure drop [kpa] 70 0,,0 0 0,7 Pressure drop [bar] 0 0, 0,0 0,,0 0,0 presssure drop over controls and valves [m³/h] Pressure drop [kpa] 70 0,,0 0 0,7 Pressure drop [bar] 0 0, 0,0 0,,0 The pressure drop is calculated for an average temperature of 70 C (PVV 80/60). For other water temperatures, the pressure drop is multiplied by the factor K. 0,0 Average temp. water C K
5 Heater Control options 3-step control of air only The air is manually controlled in three, fixed steps. No heat control, full water through the heating coil. Complete control equipment: CB30N, control panel Thermostat and 3-step control The thermostat starts/stops the fan and controls heating on/off. The air is manually controlled in 3 fixed steps. Complete control equipment: CB30N, control panel KRT900 or T0/TK0, room thermostat SWR0/5, valve set, or TVV0/5, valve + SD0, actuator Thermostat and 3-step control with save-reduction The thermostat starts/stops the fan and controls heating on/off. The air is manually controlled in 3 fixed steps. Save-reduction saves energy through lower temperatures, for example, at night and weekends. Complete control equipment: CB30N, control panel RTI, -step thermostat SWR0/5, valve set, or TVV0/5, valve + SD0, actuator KUR, time switch Controls and accessories CB30 T0 TK0 KRT900 RTI KUR T0/TK0, thermostats Processor controlled thermostats with concealed and visible dials. Setting range C. Connection voltage: 30 V. Max. breaking current: 0 A. IP30. KRT900, capillary tube thermostat Capillary tube thermostat with concealed dial. Setting range C. Max. breaking current: 6/0 A (30/400 V). IP55. RTI, electronic -step thermostat Processor controlled -step thermostat with concealed dial. Setting range C. Connection voltage 30 V (two potential free contacts). Max. breaking current: 6/0 A (30/400 V). IP44. CB30N, control panel Regulates the air in 3 steps. Supplied enclosed for wall mounting. Can regulate several units. Max. rated current: 0A. IP44. KUR, digital time switch Digital weekly timer with 8 different program steps (36 memory places) equipped with a changeover contact. Max. breaking current: 0 A. IP44. SWFT0, wire mesh filter can be fitted with a wire mesh filter. The filter is fitted in front of the heating coil (slid into the provided slots) and is accessible both from above and below the heater. Description HxBxD [mm] T0 Electronic thermostat 80x80x3 TK0 Electronic thermostat visible knob 80x80x3 KRT900 Room thermostat 65x57x60 RTI -step room thermostat 55x87x43 CB30N Control box for 55x87x43 KUR Digital time switch 75x85x05 SWFT0 Basic filter
6 regulation AV0/5 JVF0/5 TVV0/5 SD0 SWR0/5, valve set This valve set is suitable when there is need for adjusting the water and shutting it off (for the purpose of maintenance). The supply of heat is controlled by a thermostat. Pipe dimension for SWR0 is DN 0 (¾ ) and for SWR 5, DN 5 ( ). Add a suitable thermostat for controlling SWR0/5, like KRT900 or T(K)0. SWR0/5 consists of the following: AV0/5, stop valve Stops the water supply to SW. Consists of a ball valve which is either open or closed. JVF0/5, adjustment valve To adjust the water to desired. (kv value for JVF0 is 3,5 and kv value for JVF5 7,0). TVV0/5, -way regulation valve Pressure class PN6. Maximum pressure MPa (0Bar). Maximum pressure fall TVV0, 00kPa (Bar). Maximum pressure fall TVV5, 6kPa (0,6Bar). The kv value is adjustable in 3 stages: TVV0: kv,6, kv,5 and kv 3,5 TVV5: kv,5, kv 4,0 and kv 5,5 TVV0/5, valve+ SD0, actuator regulation with heat supply controlled by thermostat, but with the option of adjusting or stopping the water. Pipe dimension for TVV0 DN 0 (¾ ) and for TVV5, DN 5 ( ). Add a suitable thermostat for controlling TVV0/5 + SD0, like KRT900 or T0/TK0. For this type of water regulation the following components are required: TVV0/5, -way regulation valve Pressure class PN6. Maximum pressure MPa (0Bar). Maximum pressure fall TVV0, 00kPa (Bar). Maximum pressure fall TVV5, 6kPa (0,6Bar). The kv value is adjustable in 3 stages: TVV0: kv,6, kv,5 and kv 3,5 TVV5: kv,5, kv 4,0 and kv 5,5 SD0, actuator on/off 30V~ A thermostat controls the actuator to open and close, thereby regulating the supply of heat to SW. The closing time of the valve is 5 seconds, prevents sudden pressure changes in the pipe system. IP40. SD0, actuator on/off 30V~ A thermostat controls the actuator to open and close, thereby regulating the supply of heat to SW. The closing time of the valve is 5 seconds, prevents sudden pressure changes in the pipe system. IP40. Description SWR0 Valve set connection 0 mm (¾ ) SWR5 Valve set connection 5 mm ( ) TVV0 -way control valve 0 mm (¾ ) TVV5 -way control valve 5 mm ( ) SD0 Acutator on/off 30V~ IP40
7 Wiring diagrams 3-step control of air only CB30N, controlbox Blue Brown M ~ White Grey Black Yellow Yellow Yellow/Green 30V~ CB30N Thermostat and 3-step control T0, electronic thermostat SD0 SD0, actuator TVV0/ CB30N, controlbox >t C T0 A/B CB30N TVV0/5 two way valve L N 30 V~
8 Wiring diagrams Thermostat and 3-step control SD0 TVV0/5 SD0, actuator KRT900, room thermostat 3 KRT CB30N TVV0/5 two way valve CB30N, controlbox L N 30 V~ Thermostat and 3-step control with save-reduction SD0 CB30N, controlbox RTI, electronic -step thermostat KUR c L N TVV0/ CB30N SD0, actuator TVV0/5 two way valve RTI L N 30 V~ KUR, digital time switch
Fan heater SWT Ceiling mounted fan heater with water heat
Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and
More informationFan heater Panther Powerful fan heater for large premises
3 20 30 Electrical heat 5 models Fan heater Panther 20-30 Powerful fan heater for large premises Application Panther 20 30 is a range of powerful and quiet fan heaters for stationary use. They are intended
More informationThermozone SF. Air curtains for vertical mounting in curved doorways
Electrically heated Water heated Thermozone SF Air curtains for vertical mounting in curved doorways Thermozone SF is an ideal solution for any environment with revolving doors or curved sliders. The air
More informationThermozone RD. Air curtains for revolving doors
Electrical heat 6-36 kw Water heat Thermozone RD Air curtains for revolving doors Thermozone RD is an ideal solution for any environment with revolving doors. The air curtain is mounted on top of the door
More informationThermozone AC 300/WAC 300
Ambient, no heat Electrical heat 8- kw Hot water heat Lengths: and.7 metres Thermozone AC 00/WAC 00 AIR CURTAINS FOR DOORWAYS BETWEEN.5 AND.5 METRES The Thermozone 00-series consists of the AC variant
More informationThermozone ADR 200/300 E/W
R Thermozone ADR 200/300 E/W Electrical heat 9-18 kw Water heat Lengths: 1, 1,5 and 2 metres Thermozone ADR 200/300 E/W Recessed air curtains for doors heights up to 3,5 metres ADR is our air curtain for
More informationComfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres
Ambient on request Water heated (WL / WH) Electrically heated (E) Colour customization Lengths,.5, 2, 2.5 and 3 metres ISO 900 Comfortline L Series The appreciated, flexible Design Air curtain for mounting
More informationElztrip EZ100 Single panel radiant heater for offices, shops etc.
600-1500 W Electrical heat 3 models Single panel radiant heater for offices, shops etc. Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows
More informationElztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications
Single panel radiant heater for offices, shops etc. 3 models 3 600 1500 W Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments
More informationIndustrial infrared heater IR For premises with large volumes and high ceilings
Electrically heated 3000 6000 W 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
More informationThermozone AD Corinte
R Thermozone AD Corinte Ambient, no heat Electrical heat 15 22,5 kw Water heat Vertical: 2,2 and 2,5 metres Horizontal: 1,7 and 2,2 metres Thermozone AD Corinte Air curtains for doors with heights of up
More informationFan heater Panther WALL MOUNTED FAN HEATER
Electrical heat 6 30 Fan heater WALL MOUNTED FAN HEATER 8 models is a range of silent and efficient fan heaters for fixed installation. is available in two sizes with different outputs. 6 15 is designed
More informationOriginal instructions AR
Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5
More informationIndustrial infrared heater IR
Industrial infrared heater For premises with large volumes and high ceilings 3 models 3 3000 6000 W Application is suitabe for total or supplementary heating of premises with large volume and high ceilings.
More informationFan heater Panther 6-15 Efficient fan heater for medium size premises
Fan Heater 6-15 3 6 15 kw Riscaldamento elettrico 5 modelli Fan heater 6-15 Efficient fan heater for medium size premises Applicazioni 6-15 è una gamma di termoventilatori molto silenziosa ed efficiente
More informationOriginal instructions. Panther 6-15 kw
Original instructions 6-15 kw SE... 8 GB... 10 NL... 12 IT... 14 ES... 16 FI... 18 DE... 20 FR... 22 NO... 24 RU... 26 PL... 28 6/15 Fig 1. Bracket 100 ø7 520 90 ø6,5 ø14 450 510 Fig 2. Ceiling Wall 30
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More informationThermostats. Type Voltage Max. current Setting range Protection class HxWxD breakpoint [V] [A] [ C] [mm] RTEV C IP30 71x71x28
Thermostats RTE 0/0 RTEV 0/0/0V RTEV 0/0 RTEV 0 Electronic thermostats Setting of temperature on the RTE 0/0 is done on the circuit board under the housing to prevent unauthorised persons from changing
More informationCHH - Active Chilled Beam. Halton CHH. Active Chilled Beam
Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal
More informationThermocassette HP RADIANT HEAT CASSETTES FOR CEILING MOUNTING
Electrical heat 300 600 W Thermocassette RADIANT HEAT CASSETTES FOR CEILING MOUNTING 10 models Radiant heater Thermocassette is appropriate for heating of rooms with ceiling heights up to 3 metres where
More informationSWS SE GB NO DE ES FR IT NL PL RU... 49
SE... 17 GB... 20 O... 23 DE... 26 ES... 30 FR... 34 IT... 38... 42 P... 46 RU... 49 Fan heater 1 Fan heater 2 Mounting brackets SWB 3 Basic filter FT 4 Filter section, deep-pleated bagfilter EU3 SWF 5
More informationOriginal instructions SWX C/D NO DE ES... 26
Original instructions SE... 10 GB... 14 O... 18 DE... 22 ES... 26 FR... 30 IT... 34... 38 P... 42 RU... 46 150 A E B G ØI F C H D [mm] A B C D E F G H ØI SWX C12/D13 585 535 455 705 R3/4" 250 330 410 10
More informationCAW Ceiling-mounted fan heaters for hot water
Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot ceiling-mounted fans are used for heating entrances, warehouses, industrial premises, workshops,
More informationCarisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationAir curtains. For a comfortable indoor climate
Air curtains For a comfortable indoor climate The full range Our complete range of air curtains gives you all possibilities to get comfort and save energy in your entrance or opening, with a modern and
More informationMini Catalogue air curtains radiant heaters fan heaters convectors controls
Mini Catalogue 2007 air curtains radiant heaters fan heaters convectors controls 2007 Contents Frico 4 Thermozone Air curtains Introduction 6 Thermozone guidelines 7 Thermozone AD 100, ADA 10 Thermozone
More informationRadiant heaters - Offices, shops and public premises
Radiant heaters - Offices, shops and public premises Comfort Panel SZR recessed, water heated Comfort Panel SZR can be used for heating or cooling in buildings where water is the heating/cooling medium
More informationMetropolitan high output natural and powered trench heaters
Metropolitan high output natural and powered trench heaters High output trench heaters Typically used in large glazed areas to reduce glazing losses, these units are the perfect way to enhance comfort.
More informationWe have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems
We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationTHIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM
THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9
More informationAIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating
Air curtains Air curtains The air curtains from VEAB create an effective, separating air trap between two temperature zones, for the entrances of department stores, public spaces, offices, etc. During
More informationHalton CHB Active chilled beam with boost function for bulkhead installation
Halton CHB Active chilled beam with boost function for bulkhead installation Combined cooling, heating, and supply-air unit for bulkhead installation Different sizes, to meet various cooling and air-flow
More informationHigh wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue
High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted
More informationCOR Series AIR CURTAINS. Air curtains. Dimensions (mm) Accessories. Technical characteristics
AIR CURTAINS COR Series Designed for wall application in commercial and industrial environments. COR Can be fitted up to a height of 2,5 metres. performance tangential propeller/impeller giving a low sound
More informationWOLF WARM AIR CURTAIN
TECHNICAL DOCUMENTATION WOLF WARM AIR CURTAIN TL-2 30m 3 /h TL-2 WARM AIR CURTAIN Additional silencer mat in the discharge section Attractive intake grille with rectangular perforations, self-centring
More informationHalton CPT Passive Chilled Beam
Passive Chilled Beam Ceiling-mounted passive chilled beam Installation above an open grid or perforated ceiling Quiet operation No moving parts Well suited for spaces with high cooling loads, low humidity
More informationKPSW CONSOLE TERMINAL UNIT
TECHNICAL INSTRUCTIONS KPSW CONSOLE TERMINAL UNIT Cooling Heating KPSW.40 kw.75 kw KPSW.9 kw 4.07 kw KPSW 4.60 kw 5.0 kw November 008 0 7 - GB - 0 MARKING This product marked conforms to the essential
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure
More informationCarbon infrared heater IHC
Carbon infrared heater IHC For soft and effective heat Application Carbon infrared heater IHC produces a gentle and direct heat which together with the soft glow, is ideal for indoors and conservatories
More informationUse. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.
63 Use Lindab's supply air beam has a large cooling capacity and can therefore be used to advantage in rooms with substantial cooling requirements. In terms of appearance, looks similar to Professor. Polaris/Professor
More informationLocal Climate. Global Comfort. air curtains radiant heaters fan heaters convectors controls
Local Climate. Global Comfort. air curtains radiant heaters fan heaters convectors controls Welcome to the Frico Mini Catalogue. The Catalogue displays an overview of the Frico range of Commercial Heating
More informationUse. Worth noting. Key figures. Installation. linx industries chilled beams
71 Use Lindab's supply air beam has a large cooling capacity, uses one-way air injection and can therefore be used to advantage in rooms with small spaces and substantial cooling requirements. In terms
More informationDUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX
Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system
More informationPolaris-I-60. active chilled beam. the future of space conditioning
the future of space conditioning Polaris-I-60 active chilled beam Function Cooling and supply air with two-way air distribution Available with heating and integrated controls Application Offices, hotels,
More informationCUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams
Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available
More informationLindabCapella. Supply air beam
lindab we simplify construction Lindab Supply air beam 0.06 0.06 Lindab Ventilation Lindab Ventilation. A/S. All forms All forms of reproduction of reproduction without without written written permission
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationCBH - Active Chilled Beam. Halton CBH. Active Chilled Beam
Halton CBH Active Chilled Beam Combined cooling, heating and supply air unit for exposed wall installation Well suited for hotel guest rooms with high requirements for thermal comfort and room acoustics
More informationAir curtains. For a comfortable indoor climate
Air curtains For a comfortable indoor climate Welcome to the Frico air curtain catalogue! Our ultimate ambition is to give you the best possible support and the finest technical solutions. With this catalogue
More informationProduct is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue
cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE
More informationTechnology for life. Unit heater LH
Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables
More informationAir cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw
Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with
More informationOriginal instructions. Infrared heater IRCF...17
Original instructions Infrared heater SE...7 NO...9 GB...11 DE...13 FR...15 RU...17 Fig. 1 Fig. 2 2 Fig. 3 3 Technical specifications Infrared heater 3 Type Heat output (1) [W] Voltage (2) Amperage (3)
More informationEMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.
Thermal actuator for heating, ventilation, and air conditioning systems To be precise. Description The EMO T thermal actuator is a VDE-tested two-point actuator for connecting to room temperature controllers
More informationSun Ray Electric Radiators Stylish, Efficient, Low Energy
Sun Ray Electric Radiators Stylish, Efficient, Low Energy RADIATOR SAVING ENERGY REDUCING THE CARBON FOOTPRINT Sun Ray Radiators are aesthetically pleasing to the Eye, Stylish, Efficient, Low Energy, Easy
More informationVA G 052 S
763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY
More informationRESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators
RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING www.b Unique, slim-design baseboard radiators The RESCOM 2100 system is unlike traditional baseboard heating systems. Smooth flat panels are easily secured
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationThe new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION
The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION Experience the external venetian blind 80 S in action! www.warema.com/80s The new WAREMA external venetian blind 80 S PROVEN THINGS
More informationIndustrial ceiling fans Push down the heat from the ceiling and get significant energy savings!
Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings! FACTORY BUILDINGS GREENHOUSES INDOOR SPORTS WORKSHOPS DIY SUPERSTORES WAREHOUSES MARQUEES AGRICULTURE BEFORE
More informationConditioning your ambient, maximising your comfort.
Centrifugal fancoils for surface mounting or recessed installation. Cooling capacity from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m3/h. Cassette with radial fan.
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationFlush individual room control for floor heating systems
Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control
More informationmanifold, for radiators
MMA, for radiators Eco-friendly materials, low lead content Quiet Precise and linear Dimension: DN 0 Temperature: C to + C Pressure class: PN 0 Description Area of use The Evoflow radiator is especially
More informationSeries A28 Two stage Thermostats. Feature and Benefits
PSC9626 European Refrigeration Controls Catalogue Catalog Section 1 Product Bulletin A28 Series A28 Two stage Thermostats I ntroduction These thermostats are designed for various types of heating, cooling,
More informationVIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014
VIII. Heaters Mobile Climate Control 11 MCC Reference Manual 014 VIII.1. Whispers PN: 89-0 Heater Whisper UW-9 Very compact heater Having the same profile as the UC-9 convector, MCC heater whisper UW-9
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More informationSABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant
Air Conditioning Ceiling Air Conditioning Elegant ISO 00 - Cert. n 0/ Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Air Conditioning SABIANA ENVIRONMENTAL
More informationUse. For 2-pipe fan coils
3 015 RAB11 Room thermostats For 2-pipe fan coils RAB11.1 RAB11.. Room thermostat with manual switch for heating or cooling mode and fan function 2-position control Manual 3-speed fan switch Switching
More informationR 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :
SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their
More informationDual Pressure Controls
PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393
More informationCWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling
TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50
More informationMultibox. Floor Heating Controller Flush individual room control for floor heating systems
Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for
More informationIndustrial ceiling fans Push down the heat from the ceiling and get significant energy savings!
Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings! F AC T O R Y B UILDINGS G REENHOUSES I NDOOR S PORTS W ORKSHOPS D I Y S UPERSTORES W AREHOUSES MARQUEES AGRICULTURE
More informationThermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18
Thermocassette SE... 6 GB... 8 NO... 10 FR... 12 DE... 14 FI... 16 RU... 18 Thermocassette 305 False ceiling 300/600 605 Minimum mounting distance Min.distance [mm] Ceiling 80 Wall, long side of the unit
More informationComfort Air Curtains with in-built dynamic advertising
Comfort Air Curtains with in-built dynamic advertising www.stavoklima.eu Li-DR Air Curtains Li-DR Contents Contents: page Introduction... 2 Air Curtains Li with in-built dynamic advertising (DR)... 3 Description
More informationAir curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain
Air curtains 114 MRX condensing gas air curtain 118 MRA-H gas air curtain 121 MRA-A ventilation only air curtain 122 SW / SE hot water / electrical air curtain 124 SWR / SER built-in hot water / electrical
More informationTHERMASREG TR 040 THERMASREG TR 060
THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary
More informationUnits for suspended cei lings
. X X testregistrierung Units for suspended cei lings Type, hinged induced air grille, water connections Chilled Beams No. 09.2.432 Eurovent certification HYGIENISCH GETESTET V DI 6022 Tested to VDI 6022
More informationHRV-IP. Ceiling Type Heat Pump Heat Recovery Unit
HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger
More informationCommercial Evaporative Cooling
Commercial Evaporative Cooling The Bonaire System Advantage Bonaire has been providing innovative commercial evaporative cooling solutions for over 60 years on projects with applications which have been
More informationHelios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm
Thickness 1 mm Diameter 22 mm Pitch 2, mm Helios Unit Heater Fin 0,12 mm The HELIOS Sabiana unit heaters, built with the same criteria of sturdiness and safety that define all Sabiana products, stand out
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationUnits for suspended ceilings
X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings
More informationTechnical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw
Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationVMA-VMB NOVA AIR HEATERS. NoVa air heaters
VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling
More informationDOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,
DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded
More informationMini catalogue air curtains radiant heaters fan heaters convectors thermostats. Comfortable and energy efficient indoor climate.
Mini catalogue 2013 air curtains radiant heaters fan heaters convectors thermostats Comfortable and energy efficient indoor climate. Welcome Welcome to the 2013 edition of the Frico Mini Catalogue. We
More information1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.
AB-PM Consistent hydronic control Continuous energy savings AB-PM automatic balancing valve for a reliable and energy-saving heating system. 1 valve needed instead of 3 for pressure, flow and zone control
More informationSIGMA PRISMA LOW BODY CONCEALED
EN SIGMA PRISMA LOW BODY CONCEALED EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous
More informationCommercial Evaporative Air Conditioning
Commercial Evaporative Air Conditioning The Bonaire System Advantage Bonaire has been providing innovative commercial evaporative cooling solutions for over 60 years on projects with applications which
More informationFresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.
Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is
More information42AM. Air heaters PRODUCT SELECTION DATA
PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of
More informationNEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545
NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions
More informationCWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT
TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12
More informationCassette units Model Comfort Circle. - heating - cooling - ventilation
Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their
More information