PolyMax H2-24 Dutch Bucket System

Size: px
Start display at page:

Download "PolyMax H2-24 Dutch Bucket System"

Transcription

1 11234 PolyMax H2-24 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing FarmTek All Rights Reserved. Reproduction is prohibited without permission. Revision date:

2 Important Information READ THIS DOCUMENT BEFORE YOU BEGIN TO ASSEMBLE YOUR DUTCH BUCKET SYSTEM. This guide provides helpful hints and important information needed to safely assemble and properly maintain the PolyMax H2-24 Dutch Bucket System. Read and understand this guide before you begin. SAFETY PRECAUTIONS Apply PVC cement in a well-ventilated area. Follow all instructions on the PVC container. Use a portable GFCI (Ground Fault Circuit Interrupter) when working with electric power tools and cords. Use battery-powered tools if possible. Exercise caution when using all tools. Wear gloves and eye protection when drilling and cutting. SAMPLE ASSEMBLY PROCEDURE The steps outlining the sample table system assembly process are as follows: 1. Verify that all parts are included in the shipment. Notify customer service for questions or concerns. 2. Read these instructions and all additional documentation included with the shipment before you begin. 3. Gather the tools and assistants needed to assemble the product. WARNING: KEEP ALL ELECTRICAL CORDS AND CONNECTIONS OUT OF THE RESERVOIR. CONSULT THE SERVICES OF A QUALIFIED ELECTRICIAN TO ADEQUATELY AND SAFELY CONNECT THE PUMP TO A POWER SUPPLY. ALL ELECTRICAL CIRCUITS SHALL BE DESIGNED IN ACCORDANCE WITH LOCAL AND REGIONAL BUILDING CODES AND STANDARDS. TOOLS The following list identifies the tools needed to assemble the Dutch bucket system described within this guide. Additional tools may be needed depending on the application. Tape measure and gloves. Marker to mark locations on PVC tubing and frame. Variable speed drill (cordless with extra batteries works best). /16" drill bit 1", 1-3/8", and 2-1/4" hole saws UNPACK AND IDENTIFY PARTS The following steps will ensure that you have all the necessary parts before you begin assembly. 1. Unpack the contents of the shipment and place where you can easily inventory the parts. Refer to the Bill of Materials/Spec Sheets. 2. Verify that all parts listed on the Bill of Materials/ Spec Sheets are present. If anything is missing or you have questions, contact Customer Service. BASIC CARE AND MAINTENANCE Proper care and maintenance of your system is important. Check the following items periodically to properly maintain your Dutch bucket system. Check connections to verify that they remain tight. Verify that the pump is working properly. Check and clean all filters to optimize performance. Clean the reservoir periodically to prevent unwanted contamination of solution. Monitor temperatures (room and solution) to maximize plant growth. Warm tube with a hair dryer for easier assembly. Do not overheat! ATTENTION: Install fittings so they are fully inserted into the 3/4" tubing. Use a hair dryer to gently heat the tubing for easier installation. Do not overheat! Tube will melt! Use pliers to gently squeeze ratchet clamps around tubing Revision date:

3 PICTORIAL GUIDE Use the following graphics and photos to identify the parts of the system. Consult the Quick Start Guide for additional details and diagrams. Important Information WF Air Stone WR4067 WR109 Tape Woodpecker Drippers Heavy Duty Timer (1) AC mm Punch Ratchet Clamp Dripper Stake 2-Way Manifold MH1123 WF WF341 WF ATTENTION: This is a drain-to-waste Dutch bucket system. As such, it requires a drain or tank to capture the nutrient solution that drains from each Dutch bucket. Disposal of nutrient solution may be regulated in your area. Consult the services of a professional familiar with local and regional codes to ensure proper disposal of waste solution. WF2190 WF1380 WF1390 WF230 WF6990 (1) PVC Cement Air Pump WARNING: DO NOT ALLOW THE PUMP TO RUN WHILE RESERVOIR IS EMPTY. DAMAGE TO PUMP WILL OCCUR. MONITOR NUTRIENT LEVEL AT ALL TIMES. Revision date:

4 Important Information PICTORIAL PARTS GUIDE CONTINUED WF1982 WF6692 WF WF170 WF /8" White Polyethylene Tubing /4" White Polyethylene Tubing Dutch Bucket Siphon Elbow Clear Vinyl Tubing WF1030 with Shut-Off Valve CAUTION: Do not activate pump without first priming it. Doing so will damage the pump! Consult all documentation included with the pump before you begin Flotec Utility Pump Perlite Revision date:

5 Typical Dutch Bucket System Layout The Dutch Bucket system is typically set up as shown. Minor changes are possible depending on the available space and position of the drain. In this example, the drain end of each 1-1/2" pvc tube is opposite the reservoir. If a single floor drain is used, additional pvc tube and fittings may be needed to achieve the desired results. Contact your sales representative for additional details and to purchanse additional materials if needed. ATTENTION: Consult the Layout Diagrams on the next pages for additional layout suggestions. Actual tank may differ from examples shown. Adjust layout as needed to setup system in available space. Purchase additional materials if layout differs from any examples shown. Open/Drain End Timer 9" Space the drain holes for the Dutch buckets 18" apart. Open/Drain End 18" Space the two 1 1/2" drain 72" 11 Gallon tubes at 72" (maximum). Pump Reservoir Air Pump To Power Supply Follow these steps to assemble and set up your Dutch bucket system: 1. Determine and prepare the area where the system will be operating. Estimated system footprint is 8' x 24'. Length depends on reservoir position. 2. Follow the procedures as presented. Procedures can be completed simultaneously depending on available assistants. 3. Partially fill reservoir and test system. 4. Mix nutrient solution, fill buckets with growing medium, and add plants.. Set timer and monitor operation. Revision date: Position the first drain hole 9" in from the capped end of the pvc drain tube. ATTENTION: This is a drain-to-waste Dutch bucket system. As such, it requires a drain or tank to capture the nutrient solution that drains from each Dutch bucket. Disposal of nutrient solution may be regulated in your area. Consult the services of a professional familiar with local and regional codes to ensure proper disposal of waste solution. WARNING: DO NOT ALLOW THE PUMP TO RUN WHILE RESERVOIR IS EMPTY. DAMAGE TO PUMP WILL OCCUR. MONITOR NUTRIENT LEVEL AT ALL TIMES. 9"

6 Alternative Dutch Bucket System Layout To Power Supply Timer See dimensions noted on previous page. 11 Gallon Reservoir Air Pump Pump To Power Supply For systems that inclued the 11 gallon 36"W x 84"L reservoir, the layout above is another way to reduce the system footprint for smaller greenhouses. Consult the diagram on the next page for another example. ATTENTION: Customizing the layout of this system may require the purchase of additional fittings and tubing. Contact your sales representative for additional details and to purchanse additional materials if needed Revision date:

7 Alternative Dutch Bucket System Layout A A A TOP VIEW A A A Pump For systems that inclued the 11 gallon 36"W x 84"L reservoir, the layout above is another way to reduce the system footprint. To Power Supply Timer ATTENTION: Customizing the layout of this system may require the purchase of additional fittings and tubing. Contact your sales representative for additional details and to purchanse additional materials if needed. To Power Supply Air Pump To complete the assembly for this layout, additional purchase is required for 1" pvc elbows and 1" pvc tubing. (See A's in diagram above.) The amount of additional 1" pvc tubing depends on how overall layout is completed. Contact your sales representative to purchase additional WF170 elbows, or purchase 1" pvc elbows and 1" pvc tubing locally. See dimensions noted on previous page. 11 Gallon Reservoir Revision date:

8 1 MARK Complete these steps: AND DRILL BUCKET DRAIN HOLES Required Tools: Drill with a 1" hole saw. Example shows using a step bit. Keep holes aligned and uniform. Marker, chalk line, and tape measure 1. Connect two pieces of the WF /2" pvc using one WF1982 coupling. Seal the joint using pvc cement and allow to dry. 2. With assistance, snap a chalk line along the top, center of the pvc assembly to mark the drain hole positions from end-to-end. Drain End Assembly Instructions Drain Tube Preparation WF1982 Coupling Seal using WF6990 pvc cement. WF4140 PVC Tube Capped End Spacing for 1" Holes 18" Chalk Line 18" 9" 3. Next measure 9" in from one end and mark the position on the chalk line. 4. From the 9" line measure 18" and mark that position.. Continue marking hole locations at 18" intervals working toward the other end of the drain tube. Mark twelve (12) hole locations in all one for each Dutch bucket in the first row. 6. Take a 1" hole saw and drill the 12 drain holes in the pvc drain tube. Keep all holes aligned and centered on the chalk line. STEP 8 MH1123 Slip Cap Drain Tube DO NOT GLUE CAP. 7. After drilling the holes, clean all debris from inside the drain tube and from around the drain holes. 8. Take one MH1123 slip cap and slide it over the end of the drain tube assembly. Do not glue the cap. It is removed when drain tube is cleaned. 9. Repeat these steps to create the remaining drain tube assembly Revision date:

9 Assembly Instructions Dutch Bucket Preparation 2 ASSEMBLE AND INSTALL SIPHON ELBOWS Complete these steps: 1. Position the drain tubes on the floor of the growing area for your system. Use the diagram below or on page for proper spacing. Position the open end of tubes so they empty into the drain. Siphon Elbow 2. Assemble the siphon elbows as shown. Two (2) elbows are used for each assembly. 3. Take the elbow assembly and install one inside each Dutch bucket. 4. Using the diagram below or on page, set each Dutch bucket in place. Use 12 buckets for each row. Verify that each bucket drain nipple is inserted in the drain hole of the pvc drain tube.. Continue with the next procedure. 1 2 TYPICAL DUTCH BUCKET LAYOUT Insert drain nipple into drain hole of pvc tube Drain Tube Revision date:

10 3 DRILL RESERVOIR LID Assembly Instructions Reservoir Preparation Photo shows sample reservoir with holes in the lid. Actual lid and reservoir may differ. Two 1-3/8" holes are required for the angled return supply tubes. In addition, two /16" holes are required to connect the air pump to the air stones inside the reservoir. Complete the procedures below to drill the required holes. Drill 1-3/8" Return Supply Tube Holes 1. Move lid off reservoir. Do not drill with lid on reservoir. Debris will contaminate solution and clog pump during operation. Drill /16" Holes for the Air Pump Tubing 1. Take a /16" drill bit and drill two holes through the lid in the raised area. See photo below for location. x x 2. Use a 1-3/8" hole saw bit to drill two holes in the lid in the locations shown. See photos. Drill holes in center of raised portion. 2. Remove all debris from the lid and around all holes to prevent it from dropping into the reservoir when lid is set in place. Actual lid may differ slightly from what is shown above Revision date:

11 3 DRILL Assembly Instructions Reservoir Preparation RESERVOIR AND INSTALL BULKHEAD AND RELATED FITTINGS 1. Take the reservoir and drill the bulkhead fitting hole using a 2-1/4" hole saw bit. Review photos and diagrams for position. ATTENTION: Use the pump to determine the hole position on the reservoir. Set the pump and reservoir on the same level surface and use the diagram on the next page to mark the bulkhead location on the reservoir. Adjust as needed to ensure the entire bulkhead fitting is against the flat surface of the reservoir. Dashed line outlines area for bulkhead fitting. WF882 Step 1 Identify hole position. Use inlet side of pump to determine the center of the bulkhead fitting. REMEMBER: Entire bulkhead must remain within the flat surface of the reservoir. WF882 Bulkhead Fitting Installed Install hex nut and flat washer outside reservoir. Sample Reservoir 2. Attach the WF2392 bushing and screen to the threaded body of the bulkhead fitting. Hand tighten until snug. WF2392 Bushing Screen Install rubber seal inside reservoir. Inside reservoir photo showing fittings. 3. Attach the bulkhead assembly to the reservoir. Hex nut and thin flat washer are outside the reservoir. Tighten until snug using large adjustable pliers. 4. Continue with the next procedure. Revision date:

12 Assembly Instructions Plumbing 4 ASSEMBLE SUPPLY MANIFOLD AND CONNECT PUMP TO RESERVOIR Use the diagram below and on the next two (2) pages to construct the nutrient supply manifold and connect the pump to the reservoir and the manifold to the pump. It is best to assemble the manifold and related parts in the area where the system will be operating. ATTENTION: Do not attempt to move the system after attaching the pump to the reservoir and the manifold to the pump. Damage to the components may occur. WF6990 (1) PVC Cement See steps and digarms on the next pages. ATTENTION: Diagram is presented to display the plumbing components. Actual tank may differ from the example shown. WF170 WR109 Tape WF3316 WF WF1380 WF WF WF Revision date:

13 Assembly Instructions Plumbing 4 ASSEMBLE SUPPLY MANIFOLD AND CONNECT PUMP TO RESERVOIR continued WR109 Tape WF6990 PVC Cement 1" PVC 1" PVC Reservoir Lid WR4067 WF230 WF1380 WF230 WF2190 WF1380 WF3316 WF3316 WF1390 WF1380 WF3420 WF2190 1" PVC WF Reservoir Use the following steps as guides during assembly: 1. Gather all the components and pvc tubing shown above and on the previous page and assemble the supply manifold. TOP VIEW OF LID AND SUPPLY MANIFOLD 2. Dry fit all connections before you secure using the pvc cement. Apply WR109 tape to all threaded fittings before assembly. Apply tape in a direction that will unwind when fittings are connected. 3. After constructing the manifold, assemble the plumbing, pump, and reservoir. WF1380 WF1380 Align the WF1380 tee fittings with the center of the hole in the reservoir. See dashed lines above. Revision date:

14 Assembly Instructions Connect Pump and Manifold to Reservoir CONNECT PLUMBING TO RESERVOIR AND PUMP ATTENTION: Actual tank may differ from the example shown. WR109 Tape WF6990 PVC Cement 1. Connect pump to the reservoir. Position pump as close to the reservoir as possible with all components installed. 2. Connect main manifold to pump. Cut the vertical 1" pvc tube to a length that positions the manifold at or below the top of the reservoir. WF341 WF2193 1" PVC WF170 (x2) Vertical 1" PVC Tube 3. Assemble and connect diagonal return lines to main manifold. Length depends on pump position. 4. Measure, cut, and connect 1" pvc tubes to manifold. See next page for dimensions Revision date:

15 Assembly Instructions 3/4" Supply Lines to Dutch Buckets 6 INSTALL THE 3/4" SUPPLY LINES (111627B) TO DUTCH BUCKETS Using the diagram below, set the buckets and drain tubes in position. Construct the long 3/4" supply tubes for each row. Connect each 3/4" tube to the supply manifold using WF6692 elbows and adapters. At the end of each 3/4" supply tube (opposite the reservoir) install a AC2804 valve. Secure all 3/4" tube and fitting connections using the ratchet clamps. Cut 1" pvc tube as needed and glue to the outlet tubes of the supply manifold. Install valve in the end of each 3/4" main supply tube. Secure with a ratchet clamp. 72" Space the two 1 1/2" drain tubes at 72" (maximum). Reservoir AC2804 Drawing not to scale The main 3/4" supply tube runs along the tops of each row of Dutch buckets Ratchet Clamp WF6692 Revision date:

16 7 INSTALL DRIPPERS, 2-WAY MANIFOLDS, & DRIPPER STAKES, Assembly Instructions Drippers and Stakes NOTE: Determine dripper location before you cut tubing. Complete these steps: 1. Determine the length of drip line tubing (110408A) required for each bucket and cut the tubing to length. Two (2) lines are needed per bucket (A & B). Slide one dripper stake (110407) onto the end of each line. See note to the right. 2. Take the 2-way manifolds and attach one to each dripper (C). 3. Attach the dripper line assemblies (Step 1) to the 2-way manifolds (D & E). 4. Determine where you want to position the dripper assemblies. Punch a hole in the 3/4" supply line for each assembly using the punch (F).. Carefully install the drippers. Push the tapered nipple into the hole. Gently grip the body of each dripper assembly and gently pull up to seat the fitting in the supply line (G & H). Wet tapered end for easier installation. ATTENTION: Dripper location can be above each bucket or between the buckets depending on preference, application, and length of tubing. A B C D E F G H Revision date:

17 8 Assembly Instructions Air Pump & Air Stones ATTENTION: Always position the air pump above the reservoir/water level to prevent siphoning of the reservoir Air Stone ATTACH THE AIR PUMP AND AERATOR STONES For optimal system performance and to extend the life of the nutrient solution through increased oxygenation, an aerator pump and aerator stones are included. Position stones at the bottom of the reservoir opposite the water pump. Air pump must remain above nutrient level to prevent siphoning. 1. Choose a position for the air pump and use it to determine the length of each air tube. Cut two air tubes from the tubing. ATTENTION: Position the air pump at a level that is above the reservoir at all times to prevent siphoning of the nutrient solution from the reservoir. 2. Attach one stone to each line and set the stones in the reservoir. See photo for stone position opposite the water pump. 3. Place the reservoir lid on the reservoir and feed the tubing up through the access holes and connect the free end of each tube to the air pump. Attach tube to air stone. Air Stones ATTENTION: Position stones opposite the pump end of the reservoir. 4. Place the air pump in the position chosen in Step 1.. Connect the air pump to power and test the operation. Verify that air is filtering through each air stone. Monitor the air pump regularly to ensure proper operation of the aerator system. NOTE: When the system is fully operational, the air pump will run continuously. Do not connect the air pump to any circuit controlled by a timer or shutoff switch. 6. After testing air flow, turn off the aerator pump until the system is fully functional Revision date:

18 OPERATIONAL AND MAINTENANCE INFORMATION General Operating Instructions After assembling the Dutch bucket system, take a few minutes to check the system. Complete these steps. 1. Verify that all electrical cord ends are outside the reservoir. 2. Place all dripper stakes inside a Dutch bucket and verify that all bucket drain nipples are inside a drain tube hole. 3. Verify that all WF3316 ball valves are fully open. 4. Verify that both AC2806 in-line valves and the shut-off valves on each filter are closed.. Fill the reservoir with water to cover the pump intake. 6. Plug the air pump into a GFCI (Ground Fault Circuit Interrupter) outlet. Look for bubbles in the reservoir to verify that the air is pumping to each air stone. Remember to always mount the air pump on a surface that is above the water level. Vibrations of the pump can cause it to move. Make sure the pump does not fall into the reservoir or other liquids. 7. Consult the pump documentation and prime the pump. After pump is primed, allow it to run until water flows into the tank out of the bypass lines. If water does not flow, stop and reprime the pump. WARNING: KEEP ALL ELECTRICAL CORDS AND CONNECTIONS OUT OF THE RESERVOIR. CONSULT THE SERVICES OF A QUALIFIED ELECTRICIAN TO ADEQUATELY AND SAFELY CONNECT THE PUMPS TO A POWER SUPPLY. General Cleaning and Maintenance Instructions For optimal performance and to increase yields, check and clean the Dutch bucket system periodically. Time between maintenance and cleaning depends on the growing environment and specific use of the system. Apply the following steps as needed to ensure that your system is working properly. 1. Disconnect the main power supply to turn off all pumps. Remove the reservoir lid and inspect the inside of the reservoir. Reservoir should be cleaned each time the nutrient solution is replenished. Keep the porthole cover in place during operation to prevent light from entering the reservoir. 2. Check all plumbing and irrigation connections to ensure that all are operating as designed. 3. Replace worn or cracked irrigation lines and drippers as needed. 4. Clean the drain tubes if needed. Remove the end cap and inspect the inside of the tube. Clean the drain tube by pulling a brush or cloth through the tube. Rinse with clean water and reposition the drain tube for operation.. With the pump off, disassemble the filters and clean the screen and housing. Reassemble for use. 6. See the procedures on the next pages for details. USING THE TIMER ALL ELECTRICAL CIRCUITS SHALL BE DESIGNED IN ACCORDANCE WITH LOCAL AND REGIONAL BUILDING CODES AND STANDARDS. 8. Check each Dutch bucket to ensure that water is dripping from each dripper stake. See next page for pressure adjustments. 9. Check all plumbing connections supply and drain tubes for leaks. 10. Check all pvc fittings for leaks. 11. Once air is out of the lines and water drips from each dripper, turn off the pump. 12. Once the system has been checked and all adjustments are made, it is ready for use. The timer allows for a variety of settings to control the water pump of your Dutch bucket system. Consult the guide supplied with the timer for installation, use, programing, and troubleshooting details. NOTE: Do not connect the air pump to the timer. Air pump must run continuously when system is in operation Heavy Duty Timer Revision date:

19 OPERATIONAL AND MAINTENANCE INFORMATION SETTING THE SYSTEM PRESSURE The Woodpecker drippers (below) require a minimum of 7 for operation. Operating pressure range is 7 to 4. To prevent damage to the drippers, do not exceed 4. After checking the system and ensuring that all components are functioning, check the pressure. Pressure can be increased or decreased by opening and closing the WF3316 ball valves. Pressures for each bank of Dutch buckets should be similar. Adjust ball valves to change the pressure and bypass flow. REMEMBER: Valves work together. Adjust as needed to get the desired system operating and bypass flow. Mark valve positions if desired to reset after performing system maintenance. WF3316 B B Woodpecker Drippers ATTENTION: Actual tank may differ from the example shown. Valves A: Use these valves to isolate either side of the system during routine maintenance, cleaning, and changing filters. They can also be used to take either side of the system out of production. Valves B: Use these valves to control pressure. For best results, valves should remain at least half open. This maximizes aeration and flow to the reservoir to stir settled nutrients and keeps the within the desired range of drippers. Recommended operating system pressure is Adjust as needed to achieve this range. A Revision date:

20 OPERATIONAL AND MAINTENANCE INFORMATION RESERVOIR CLEANING AND MAINTENANCE Clean the reservoir periodically to maximize plant growth and to minimize system contamination. The steps that follow can be used to pump the reservoir for cleaning and typical maintenance. Cleaning the filter is strongly recommended after cleaning the reservoir Shutoff Valve ATTENTION: SYSTEM SHOWN DIFFERS FROM ACTUAL SYSTEM. FILTER ASSEMBLY IS THE SAME. STEPS FOR CLEANING RESERVOIR ARE THE SAME. 1. Turn off pump and connect a garden hose to the shutoff valve on filter. Place end of hose in a bucket or run it to the desired location. 2. Open the shutoff valve on the filter and turn the pump on to pump out the reservoir. Turn off the pump once the reservoir is empty. 3. Clean the reservoir as needed and repeat the steps to pump it out again if needed. Close the shutoff valve. 4. Remove the hose and clean the filter. See next page for procedure.. Refill the reservoir with nutrient solution. 6. Turn on pump and check dripper stakes to ensure they are working. Clean if needed Revision date:

21 OPERATIONAL AND MAINTENANCE INFORMATION Clean the Filter Screen and Housing Clean filters ensure proper flow. Filters should also be cleaned after cleaning reservoir to remove sediment. When a reduced flow rate or drop in pressure is noticed, follow these steps to clean filters and filter housings. ATTENTION: SYSTEM SHOWN DIFFERS FROM ACTUAL SYSTEM. FILTER ASSEMBLY IS THE SAME. STEPS FOR CLEANING THE FILTER ARE THE SAME. Flow Flow 1. Turn off pump. Open valve on the filter to drain the supply line and filter. 2. Grip the filter housing and the main supply line and unscrew the housing. Do not apply force to the filter or the supply line fittings. Hold these steady when disassembling the filter. 3. Remove the screen from the housing. Using clean water, rinse the housing and the screen. 4. Insert the screen back into the housing, reassemble the filter, and close the valve.. Turn on pump and check flow to each bucket. 6. Check filter for leaks. Revision date:

22 OPERATIONAL AND MAINTENANCE INFORMATION FLUSH THE 3/4" SUPPLY LINES In addition to cleaning the reservoir, periodically flush the 3/4" lines that supply nutrient solution to the two rows of Dutch buckets. Complete these steps: 1. Turn off the pump. WF After cleaning the reservoir and the filters as described, add clean water to the reservoir to cover the pump intake. AC2804 at the end of each 3/4" supply tube. 3. Close the WF3316 ball valves as needed to direct water to one row of the Dutch buckets. 4. Open the AC2804 in-line valve at the end of that row.. Clear the area around the end of the line or hold a bucket over the 3/4" line. Open or close A valves to direct water to one row of buckets to flush lines. B B Close B valves to prevent water flow to reservoir to flush lines. NOTE: Pressurized water will stream out of the line. Take the necessary steps to contain the water as needed. A 6. Turn on the pump and allow water to flow through the line to flush it. 7. Turn off pump and check water level in the reservoir. Add water if needed. 8. Set the WF3316 valves as needed to direct water to the other row of buckets. 9. Repeat the steps to flush that line. 10. Verify that both AC2804 valves are closed and refill the reservior with nutrient solution. 11. Turn on the pump, adjust ball valves as needed, and monitor the system to ensure it is operating as desired. ATTENTION: Actual tank may differ from the example shown Revision date:

23 ADDITIONAL INFORMATION DRIPPER STAKES GETTING STARTED The easy-to-use stakes are perfect for even and consistent nutrient delivery. After filling the buckets with the selected growing medium, determine what nutrient solution is needed for your plants and mix this according to the instructions on the mixture. Mixture will be specific to system, the reservoir size, and the plants grown. ATTENTION: Water quality affects the nutrient solution. Testing the water supply is strongly recommended before you mix the nutrient solution. In some instances and for best results, it may be necessary to treat the water supply. Consult the services of a water quality professional to determine the condition of the water and how to treat it (if necessary) before you begin. Add your desired plants to the buckets. Set the stakes inside each bucket and turn on the circulation pump. Check each stake to ensure that water flows freely from each. Turn off the pump. Gently push the stake into the growing medium. Revision date:

24 OPTIONAL ACCESSORIES* Depending on the plant and application, using Tomato RollerHook Assemblies and the or clips can save time and labor. The RollerHook components are easily assembled by slipping the spool between the wire ends of the hanger. Position the spool so the lock is next to the lowest part of the wire spring. See the photos below. After assembling each, consult the following page to view installation photos using the assemblies and the / clips. OPTIONAL ACCESSORIES ADDITIONAL PURCHASE REQUIRED *Additional purchase required: Contact your sales representative to purchase Tomato RollerHook Assemblies for your Dutch bucket recovery system. ATTENTION: Photo to the right shows the spool incorrectly installed in the wire hanger. When installed this way, the spool lock slides under the lock spring of the handle. As a result, the cord will unravel from the spool. The installation steps below show the correct orientation. Incorrect Spool Lock Correct Revision date:

25 OPTIONAL ACCESSORIES ADDITIONAL PURCHASE REQUIRED INSTALLING THE TOMATO ROLLERHOOK ASSEMBLY* As plants mature, it may become necessary to provide adequate support. The Tomato RollerHook Assembly used with the or tomato clips provide the perfect support system, saving you time and money. 1. Hang the assembled RollerHook from a wire, cable, or frame member above the Dutch bucket system. 2. Pull cord from the spool so it reaches the desired Dutch bucket. 3. Take one or clip, wrap it around the stem of the plant, feed the cord into the hinged part of the clip, and snap the clip closed to lock cord in place. 4. Move back to the cord spool and tighten to remove slack. To prevent plant damage, do not overtighten. As the plant grows, add additional clips as needed for support. *Additional purchase required: Contact your sales representative to purchase Tomato RollerHook Assemblies for your Dutch bucket recovery system Revision date:

26 OPTIONAL ACCESSORIES ADDITIONAL PURCHASE REQUIRED Photo shows using the RollerHook Assembly Revision date:

27 PAGE RESERVED FOR CUSTOMER NOTES AND RECORDS Revision date:

PolyMax H1-10 Dutch Bucket System

PolyMax H1-10 Dutch Bucket System 112529 PolyMax H1-10 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. STK# DIMENSIONS 112529

More information

Dutch Bucket Row Kits

Dutch Bucket Row Kits Dutch Bucket Row Kits *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. 2017 FarmTek All Rights Reserved. Reproduction

More information

HydroCycle Vertical Aeroponic Systems

HydroCycle Vertical Aeroponic Systems HydroCycle Vertical Aeroponic Systems 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. *Actual system may differ from system shown. 113593 8' Vertical System (44

More information

HydroCycle Vertical Aeroponic Systems

HydroCycle Vertical Aeroponic Systems HydroCycle Vertical Aeroponic Systems 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. 113700 4' Vertical System (24 Grow Sites) Revision date: 01.10.18 1 Important

More information

Whole Bay Dutch Bucket System

Whole Bay Dutch Bucket System Whole Bay Dutch Bucket System PolyMax Dutch Buckets *Actual system may differ. Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. 2017 FarmTek All Rights Reserved.

More information

Ebb & Flow System

Ebb & Flow System 113501 Ebb & Flow System Actual system may differ from what is shown. System requires a timer to control the main pump and to set watering cycles. Additional purchase required. 2016 FarmTek All Rights

More information

Dutch Bucket Feed Pump Station

Dutch Bucket Feed Pump Station 113114 Dutch Bucket Feed Pump Station 2017 FarmTek All Rights Reserved. Reproduction is prohibited without permission. STK# 113114 Feed Pump Station Revision date: 08.09.17 1 Important Information READ

More information

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

PIPE DREAMS 96. Aeroponic Garden IMPORTANT: 1 WARNING: BEFORE PUTTING WATER PUMP INTO OPERATION FILL UP NUTRIENT TANK TO TOP OF PUMP. THE PUMP MUST NEVER RUN DRY OTHERWISE, WARRANTY WILL BE DECLINED. READ FILLING INSTRUCTIONS BEFORE USE. Welcome

More information

ClearSpan Fabric Room Divider Installation Guide

ClearSpan Fabric Room Divider Installation Guide ClearSpan Fabric Room Divider Installation Guide Actual room divider may differ from the example shown above. 2009 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

Assembly of an F12 Hydroponic Tower

Assembly of an F12 Hydroponic Tower Assembly of an F12 Hydroponic Tower Congratulations on your purchase! Your Foody tower will provide years of fresh produce and healthy eating. But first it must be assembled:) Following these assembly

More information

MULTI FLOW HYDROPONIC SYSTEM

MULTI FLOW HYDROPONIC SYSTEM MULTI FLOW HYDROPONIC SYSTEM Thank you for purchasing the Multi Flow Hydroponic System. The Multi Flow is an ebb and flow or fill and drain type hydroponic system. The operation is simple, the pots are

More information

Manual update 2016 MC37/MFC3600

Manual update 2016 MC37/MFC3600 Manual update 2016 MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You

More information

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating

More information

BURWELL BIDET TOILET SEAT INSTALLATION

BURWELL BIDET TOILET SEAT INSTALLATION BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability for any damage to the product, plumbing, toilet,

More information

Manual for MC37/MFC3600

Manual for MC37/MFC3600 Manual for MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel

More information

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007 Assembly- and Usermanual Rainmaker Code No. 99-97-1729 GB Edition: 09/2007 Table of contents Page I 1 Overview and system specifications.................................. 1 1.1 Purpose of Evaporative

More information

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company Overview The DEMA Easy Dose is a simple and reliable chemical delivery system. Easy Dose features an electronic control system

More information

Manual for MC91 SETUP INSTRUCTIONS

Manual for MC91 SETUP INSTRUCTIONS Manual for MC91 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle

More information

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

4-1 1 / 2  Tees / 2  hole saw w/ 1/4 drill bit / 2  Male slip plugs Section 1: Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union

More information

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI) Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation

More information

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION ClearChoice Economy Under Sink Drinking Water System OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION Congratulations on the purchase of your ClearChoice

More information

Super Deluxe Controller Assembly AC2089 & Base Kit AC2055

Super Deluxe Controller Assembly AC2089 & Base Kit AC2055 Super Deluxe Controller Assembly AC2089 & Base Kit AC2055 SIMPLE STEP-BY-STEP INSTRUCTIONS FOR INSTALLATION OF YOUR AQUA COOL COOLING SYSTEM 1) Plumb water line into check valve. 2) Thread check valve

More information

Installation & Service Guide

Installation & Service Guide Reverse Osmosis Ontario Soft Water.ca Kitchener, Canada 519-579-0500 Installation & Service Guide Pentair 75 gpd Encapsulated Membrane System Standard System 75gpd Membrane Your New Reverse Osmosis System

More information

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization Minor Home Repairs 1 November 4, 2017 County of Henrico Department of Community Revitalization Educate homeowners on basic technical skills that will help the homeowner understand daily operations of different

More information

Welcome! Today s topic: Small Home Repairs. November 14, 2015

Welcome! Today s topic: Small Home Repairs. November 14, 2015 Welcome! Today s topic: Small Home Repairs November 14, 2015 Small Home Repairs Course Presented by Monique Johnson Environmental Green Solutions, LLC Objective Educate homeowners on basic technical skills

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

Alkaline RO System INSTALLATION MANUAL

Alkaline RO System INSTALLATION MANUAL Alkaline RO System INSTALLATION MANUAL 1-800-992-8876 Customer Support Disclaimer All rights reserved. All material published on this site by Express Water Inc., including all portions of the website,

More information

Sinks A clog, low water pressure a nonfunctioning sink can practically shut

Sinks A clog, low water pressure a nonfunctioning sink can practically shut EXPRESS FACELIFT I CHAPTER 1 I Sinks A clog, low water pressure a nonfunctioning sink can practically shut down a kitchen. It s good to know that minor repairs can get your sink up and running in no time.

More information

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS IMPORTANT! Read all of these instructions before installing the dishwasher. AUTOMATIC HIGH LOOP The drain hose is fastened to the back of the machine at the

More information

How to Build A State-of-the-Art, High Yielding Aeroponic Growing System

How to Build A State-of-the-Art, High Yielding Aeroponic Growing System How to Build A State-of-the-Art, High Yielding Aeroponic Growing System Table Of Contents: Page I. Introduction 3 a. What is Aeroponics? 3 b. Why is aeroponics used? 3 II. What You Will Need and Where

More information

Aloha Vertical Victory Garden

Aloha Vertical Victory Garden Aloha Vertical Victory Garden User Guide Thank you for choosing our Aloha Vertical Victory Garden. Edible gardening is fun, healthy, it tastes great and it s very satisfying. We are pleased that you can

More information

Maintenance 5-1. Good maintenance is essential for cleaning results, and long economical life of the washer.

Maintenance 5-1. Good maintenance is essential for cleaning results, and long economical life of the washer. Maintenance 5-1 5 Maintenance Purpose This chapter discusses the maintenance of your StingRay Parts Washer. In general, the washer is not maintenance-intensive. A few key items, however, need regular,

More information

Power Washer Maintenance

Power Washer Maintenance Power Washer Maintenance Purpose The maintenance of your MART Power Washer. In general, the washer is not maintenance-intensive. A few key items, however, need regular, scheduled care: Use the information

More information

Manual for MC21A SETUP INSTRUCTIONS

Manual for MC21A SETUP INSTRUCTIONS Manual for MC21A SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle

More information

Setup. Important. Texture Spraying (material supplied from unit)

Setup. Important. Texture Spraying (material supplied from unit) Setup Setup Important If you are going to stop spraying for more than 5 minutes, turn sprayer off to prevent shortened pump hose life. Do not allow material to dry inside pump, hoses, gun or spray system.

More information

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / 27-009, 27-010, 27-015, 27-020 IMPORTANT INFORMATION UNATHORIZED CHANGES OR ALTERATIONS TO ANY LINCOLN PORTABLE VACUUM SYSTEM WILL AUTOMATICALLY

More information

HEDMAN DI-50. Endorser Instructions. Hedman DI-50 Operators Guide

HEDMAN DI-50. Endorser Instructions. Hedman DI-50 Operators Guide HEDMAN DI-50 Endorser Instructions Hedman DI-50 Operators Guide 25-0132-20 TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 DI-50 Description...1 1.2 Items Included...1 1.3 Safety Terms...2 1.4 Safety Precautions...3

More information

How to Fix a Leaky Toilet:

How to Fix a Leaky Toilet: How to Fix a Leaky Toilet: First, determine the type of toilet you have. Pressurized Toilet: Inside this toilet is a sealed tank. When water is fed from the water line, the air inside the tank is compressed.

More information

Hydrotherapy Jets (Remote Water Quality System)

Hydrotherapy Jets (Remote Water Quality System) Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree

More information

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions? Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Instruction Manual. Cheese Warmer with Pump

Instruction Manual. Cheese Warmer with Pump Instruction Manual Cheese Warmer with Pump 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2013 Gold Medal Products Co. Part No. 38298 SAFETY PRECAUTIONS Page 2 INSTALLATION INSTRUCTIONS Inspection

More information

FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX CHARLOTTE, N.C TEL#: FAX#:

FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX CHARLOTTE, N.C TEL#: FAX#: FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX 411047 CHARLOTTE, N.C. 28241-1047 TEL#: 1-704-588-9611 FAX#: 1-704-588-4730 CONTENTS 1. System Overview 2. Air and Electrical Requirements

More information

COBRA -H EXTRACTOR 120V

COBRA -H EXTRACTOR 120V COBRA -H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

More information

HE120, HE160 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and

More information

EDISON DUAL HANDLE VESSEL SINK FAUCET

EDISON DUAL HANDLE VESSEL SINK FAUCET SKU(s): 929281 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability for any damage to the faucet, plumbing,

More information

OptiSoft Softeners Simple Install Steps 1-17

OptiSoft Softeners Simple Install Steps 1-17 OptiSoft Softeners Simple Install Steps 1-17 (models OS-10, OS-13, OS-20 & OS-29) Refer to Installation, Operation & Maintenance Manual for More Details v Installation Requirements Installation must conform

More information

30 Misting/Oscillating Fan Model Number 01030

30 Misting/Oscillating Fan Model Number 01030 30 Misting/Oscillating Fan Model Number 01030 READ AND SAVE THESE INSTRUCTIONS CAUTION: Before using this product read this manual and follow all safety rules and operating instructions. Failure to comply

More information

ADVANTAGE-100H-SC EXTRACTOR

ADVANTAGE-100H-SC EXTRACTOR ADVANTAGE-100H-SC EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE

More information

INSTALLATION GUIDE HIGH PRESSURE CLEANER (1800C) If there is any question during using, please feel free to contact us by

INSTALLATION GUIDE HIGH PRESSURE CLEANER (1800C) If there is any question during using, please feel free to contact us by INSTALLATION GUIDE HIGH PRESSURE CLEANER (1800C) Contact us If there is any question during using, please feel free to contact us by email: service@paxcess.com sale05@gadgetwoo.com After unpacking the

More information

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL KING COBRA 310 120V INFORMATION & OPERATING INSTRUCTIONS U. S. PRODUCTS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL 56041963 IMPROPER USE OF THE MACHINE

More information

BACK WASH INSIDE THE SPA

BACK WASH INSIDE THE SPA BACK WASH INSIDE THE SPA Lower the temperature to 90 degrees and let the unit run approximately 10-15 minutes. This gives the heating element the chance to cool down. Now unplug the power pack Using a

More information

Sloan AQUS Installation Instruction, Operation, and Maintenance Guide

Sloan AQUS Installation Instruction, Operation, and Maintenance Guide Code No: 0816444 Rev. 3 (09/10) Models HMA-7000 HMA-7000-EU (Euro) Sloan AQUS Installation Instruction, Operation, and Maintenance Guide The Sloan AQUS is designed to reuse sink water as an alternative

More information

5700-E Sediment Filter Installation & Start-Up Guide

5700-E Sediment Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com 5700-E Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

Installation Instructions Built-In Dishwasher

Installation Instructions Built-In Dishwasher GE Consumer & Industrial Appliances Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these

More information

173 Index of Materials

173 Index of Materials 73 Index of Materials IBC Tank 9 Polystyrene Sheet 2 200 Litter Blue Barrels 0 Plumbers Tape (Teflon) 3 Fish Tank Shading Cable Ties 4 Plastic Net 2 Waterproof Eclectic Box 5 Concrete Blocks 3 0 mm Wide

More information

Owner's Manual. WS Series. Water Softener

Owner's Manual. WS Series. Water Softener Owner's Manual WS-165-150 Series Water Softener Table of Contents WHAT'S INCLUDED 3 OPERATING CONDITIONS 4 ASSEMBLY INSTRUCTIONS 6 FLUSHING THE WATER LINES 13 MASTERPROGRAMMING 14 PROGRAMMING KEYAND GENERAL

More information

Tsunami 6 Site Ebb & Flow Gro System Instruction Manual

Tsunami 6 Site Ebb & Flow Gro System Instruction Manual Notes: 1 Square = Foot / Feet Hydrogardening Bucket Systems Tsunami 6 Site Ebb & Flow Gro System Instruction Manual Featuring Titan Controls Oceanus 3 Controller VANCOUVER, WASHINGTON U.S.A. www.flo-n-gro.net

More information

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters Operating Instructions for the BBO-1 and BBO-2 Basket Blasters 2101 West Cabot Boulevard Langhorne, PA 19047-1893 www.empire-airblast.com Page 2 Model Number: Serial Number: Date of Purchase: Date of Installation:

More information

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax Part# 1000692 7/12/99 tn INSTRUCTIONS This manual contains important information concerning the installation and operation of the gun washers listed at the right. Read manual thoroughly and keep for future

More information

CAOL VESSEL SINK FAUCET INSTALLATION

CAOL VESSEL SINK FAUCET INSTALLATION SKU(s): 926652 CAOL VESSEL SINK FAUCET INSTALLATION BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability

More information

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply 11 INSTALLATION Installation Overview Choosing the proper location Unpacking and removing shipping bolts Connecting the water line Connecting the drain line Leveling the washer Connecting to the power

More information

SolidFlo G2 Solid Handling Pumps Product Manual

SolidFlo G2 Solid Handling Pumps Product Manual SolidFlo G2 Solid Handling Pumps Product Manual For Models: SolidFlo G2 1250 (Item #130030) SolidFlo G2 2000 (Item #130031) SolidFlo G2 2650 (Item #130032) SolidFlo G2 3600 (Item #130033) Table of Contents:

More information

Installation Instructions

Installation Instructions Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model

More information

WS1 Greensand Installation & Start Up Guide

WS1 Greensand Installation & Start Up Guide WS1 Greensand Installation & Start Up Guide Thank you for purchasing a WS1 Water System for the removal of iron, manganese and hydrogen sulphide gas. With proper installation and a little routine maintenance

More information

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers Installation Tips and Procedure For OTR-KFC Table Assembly And Auto-Fill Connection Instructions Apply For Model PHTT-6P-KFC TO DETERMINE TABLE PLACEMENT: Faces Front: Control Side of the units. APPROVED

More information

PowerGrower. 8-Pack. Assembly Guide

PowerGrower. 8-Pack. Assembly Guide PowerGrower 8-Pack Assembly Guide POWERGROWER 8-PACK PARTS 1 18 17 16 2 15 3 4 5 6 7 8 9 10 11 12 13 14 POWERGROWER 8-PACK PARTS: 1: Reservoir & Controller (2) 2: Reservoir & Controller Lid (2) 3: Hatch

More information

This site is based on a but applies to all 1971-on Saab 99 and Saab 900.

This site is based on a but applies to all 1971-on Saab 99 and Saab 900. by Mark Jeter updated: December 8, 2004 originally web-published June 27, 2001 This document shows how the original waterpump in a Saab "B" engine can be eliminated and replaced with a reliable, efficient

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-16-VD CS5-16-VD-TB CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Operation & Maintenance Manual 60HZ Models Table of Contents:

More information

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Premier Elite Premier PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 360745P Revision

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

Model K 280 M Part No

Model K 280 M Part No Model K 280 M Part No. 1.189-205.0 High Pressure Washer Operator Manual Overview...................................1 Precautions................................1-3 Assembly Instructions.........................3

More information

Installation. Please keep this manual for future reference.

Installation. Please keep this manual for future reference. Installation Tecma Bathroom Anywhere Owner s and Installation Manual Please keep this manual for future reference. Read ALL these instructions before installing the Tecma Bathroom Anywhere unit. Warning

More information

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt, Aqua-Pure is a market leader in water filtration. In addition to our comprehensive range of Domestic Water Purifiers, we design and manufacture an extensive commercial and industrial range of purification

More information

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop APEX Water Filters pure water in every drop MODEL RO 5 INSTRUCTION MANUAL Treat your body to pure goodness with Apex filtered water A Water supply adapter valve B Cold water shut-off valve C Hot water

More information

Ozone Generator Systems

Ozone Generator Systems PZ2-1 & PZ2-2 - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal

More information

Ozone Generator Systems

Ozone Generator Systems PZ2-4V - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear

More information

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system. Owner's Manual for household use only Please read this document carefully before installing and/or using your vacuum cleaning system. Model : Serial No : Important Safety Instructions When using an electrical

More information

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY MIRAI EXTRACTOR 100V LOCATOR 1 2 3 4 MODE VAC 1 VAC 2 PUMP BYPASS INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE

More information

20-GALLON PARTS WASHER OWNER S MANUAL

20-GALLON PARTS WASHER OWNER S MANUAL 20-GALLON PARTS WASHER OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

1-866-PENNERS

1-866-PENNERS Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Premier Elite Premier PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 360745P Revision

More information

Gen II Entree Bath - All Models

Gen II Entree Bath - All Models Gen II Entree Bath - All Models Installation Manual Important Safety Instructions Read & Follow All Instructions Thoroughly Important safety instructions. Read and follow all instructions thoroughly. CAUTION:

More information

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Note: Zurn Grease Interceptors with grease recognizing sensors are efficient appliances designed to separate grease from water.

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL F OR I NGROUND P OOLS INSTALLATION AND OPERATION MANUAL How Solar Pool Heating Works Why SunHeater TM Works Best Using your pool pump, water is automatically pumped through the solar collectors. The water

More information

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged. FLOOD KING 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS. IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always be sure

More information

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions IMPORTANT INFORMATION Revised Dishwasher Installation Instructions To obtain a revised copy of the entire Dishwasher User s Manual, go to www.eurotechappliances.com. SPECIAL EDITION 11-20-02 SAVE THESE

More information

KITCHEN FAUCET COS-KF222C

KITCHEN FAUCET COS-KF222C KITCHEN FAUCET COS-KF222C USER S MANUAL & INSTALLATION GUIDE Thank You Thank you for your purchase. We know that you have many brands and products to choose from and we are honored to know that you have

More information

installation and operation manual for Hunter Ceiling Fans

installation and operation manual for Hunter Ceiling Fans For Your Records and Warranty Assistance Model Name: Catalog/Model No.: Serial No.: Date Purchased: Where Purchased: For reference also attach your receipt or a copy of your receipt to the manual. installation

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com π H-2268 SANITAIRE UPRIGHT VACUUM 1-800-295-5510 uline.com SAFETY PAGE 1 OF 7 NOTE: When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS

More information

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the floor, walls,

More information

HE360 Humidifier Installation Kit

HE360 Humidifier Installation Kit HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that

More information

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6

More information

BEFORE OPERATING THE MACHINE: WARNING

BEFORE OPERATING THE MACHINE: WARNING BEFORE OPERATING THE MACHINE: Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this

More information

SuperKlean Washdown Products

SuperKlean Washdown Products DURAREEL DR8 & DR8S INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** GENERAL WARNINGS High pressure and hot

More information

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA OzoneAX 3 T Vacuum-ultraviolet Ozone Systems Installation & Operation anual odel OZ-SPA A. Important Safety Instructions IPORTANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety

More information