Ultrasonic Cleaners. Eco-Clean. Instruction Manual
|
|
- Helen Miles
- 5 years ago
- Views:
Transcription
1 Ultrasonic Cleaners Eco-Clean Instruction Manual
2 1 List of contents 1 List of contents... Page 02 2 Tips on using the manual... Page 03 3 Safety instructions... Page 04 4 Warranty... Page 06 5 Device overview... Page 07 6 Technical data... Page 09 7 Operation... Page 11 8 Troubleshooting... Page 20 9 Care and Maintenance... Page Cleaning products... Page Telefax form... Page 23 2
3 2 Tips on using the manual This manual has been written for the device user to ensure a problem-free operation, care and maintenance. Important instructions and information concerning safety and operational reliability have been highlighted. The symbols used in the manual have the following meanings: CAUTION! IMPORTANT! INFORMATION! Working and operating processes which must be observed to the letter to exclude any risk to persons. Working and operating processes which must be observed to the letter to avoid any damage to the device. Technical information to which the device operator must give special attention. The illustrations and diagrams are numbered in sequence within each chapter. Some of these illustrations have keys. References to illustrations within the text e. g. (5.1/2) have the following meaning: 5.1 = Figure = Position 2 in the key to the figure. Please feel free to call our customer service department at any time should you encounter technical problems which are not dealt with in this manual: Telephone +49 (0) / Telefax +49 (0) / INFORMATION! Spare parts lists and operating manuals for our products are to be found at 3
4 3 Safety Instructions This device has been built according to the latest technical standards and generally accepted safety regulations. Nevertheless, it can constitute danger to life and limb for operator or third parties and a hazard to the device itself or other equipment during use. IMPORTANT! (1) Only use the device if in perfect working order and for its intended purpose. You must always pay attention to the instruction manual and safety instructions therein and be aware of the risks! Repair any faults which could affect the device s safety immediately by yourself or have these repaired. The unit is designed exclusively for cleaning workpieces using the cleaning liquids recommended by the manufacturer. Any other use will be deemed to be contrary to its intended purpose. The manufacturer cannot be held liable for any resulting damages. The risk is borne solely by the user. Correct use also includes compliance with the instruction manual and an observation of the care and maintenance conditions. (2) Keep the instruction manual handy at the device s place of use. (3) Pay attention to and observe generally applicable statutory and otherwise binding regulations relating to accident prevention and environmental protection in addition to the information provided in the instruction manual! CAUTION! (4) All personnel commissioned to work on or with the device must have read this instruction manual, and particularly the safety instructions chapter, before starting work. This applies especially for personnel who only work with the device occasionally. (5) Stop the device immediately should you notice changes to the device or its operating behaviour that are relevant to its safety. Have these remedied before restarting work. (6) Observe the safety instructions on the device and keep them legible. (7) If changes in the device relevant to safety occur or the operating behaviour is modified, shut the device down immediately. Have the malfunctions remedied. (8) Do not carry out any modifications, additions or conversions to the device! This also applies to the installation and adjustment of safety equipment. (9) Spare parts must meet the technical requirements specified by the manufacturer. This can only be guaranteed with original JOKE spare parts. 4
5 3 Safety Instructions (10) Any work on/with the device may only be carried out by qualified, appropriately trained and authorised personnel. Pay attention to minimum statutory age limits! (11) Personnel undergoing training or in a general apprenticeship should only be allowed to work with the machine under the constant supervision of an experienced operator! (12) Restrain from any type of work that could jeopardise your safety. (13) The device may only be used if all protective and safety equipment is in place and in proper working order. (14) Do not leave the device unattended when switched on! (15) Stop and secure the device immediately in the event of malfunctions! Faults must remedied at once. (16) Do not clean live creatures (animals and plants) in the device! VORSICHT! CAUTION! (17) Do not reach into the ultrasonic bath during the ultrasonic cleaning! (18) Cavitation noises are generated during the ultrasonic cleaning. 5
6 3 Safety instructions 6
7 4 Warranty Joisten & Kettenbaum warrant the correct manufacture of every Joisten & Kettenbaum product which is delivered in accordance with the terms of contract and delivery. This warranty does not cover damages caused by normal wear and tear, incorrect handling, negligent use, the fitting of non-original spare parts, inadequate care and/or a failure to comply with this technical manual. IMPORTANT! The device may only be used by appropriately trained personnel. If it is not, all warranty claims will be forfeited according to the terms of delivery. 7
8 5 Device overview Purpose The JOKE ultrasonic cleaners with frequency switching are exclusively intended for cleaning of workpieces with the cleaning liquids recommended by the manufacturer. The device is particularly suitable for lapped/polished workpieces or objects (devices in the medical, dental, laboratory and optical field, clocks and jewellery), in which the smallest cavities or undercuts exist and mechanical cleaning is not successful. If all the instructions for handling are complied with, ultrasonic cleaning represents an extremely gentle and thorough form of cleaning Fig. 5.1 View of controls 1 Timer for ultrasound operation. Adjustment options: 1-15 min. for short operation (with automatic switch-off) permanent setting (manual switch-off) 2 Ultrasound output selection switch for 2 cleaning settings. power: for intensive cleaning and soft: for gentle cleaning of sensitive parts 3 Heating switch 4 Controller for heating thermostat C 5 Ultrasonic control light indicates ultrasound operation 6 Heating control light indicates heating operation 8
9 5 Device overview Cleaning principle Ultrasonic transmitters are arranged under the base of the vibration trough, which convert electrical energy into mechanical vibrations. The cleaning liquid in the trough is excited with 35 KHz and caused to vibrate. At the same time, tiny vacuum bubbles are formed which implode (cavitation) resulting in pore-deep cleaning of the parts arranged in the cleaning liquid. Select the desired output setting according to the cleaning intensity required: Soft Gentle cleaning to remove light soiling and for sensitive surfaces. Power Intensive cleaning for stubborn soiling, in addition to rapid cleaning for robust surfaces. Sweep The working frequency is continuously modified within a defined range. As a result, the minima and maxima of the sound field is spatially displaced in the trough. A more even load on the ultrasonic transmitter is also achieved. The cleaning effect is more uniform than in normal operation. 9
10 6 Technical data Eco-Clean 30 HA Eco-Clean 50 HA Eco-Clean 70 HA Eco-Clean 140 HA Max. trough filling volume (litres) Trough working volume (litres) Trough dimensions W x D x H (mm) Device external dimensions W x D x H (mm) 240x130x x130x x150x x240x x205x x205x x225x x315x350 Trough / housing material Stainless steel Stainless steel Stainless steel Stainless steel Drain 3/8 3/8 3/8 1/2 Weight (kg) 7,1 8,3 9,6 13,2 Basket internal dimensions W x D x H (mm) 216x106x52 216x106x80 276x126x80 276x216x140 Mesh size of basket (mm) Mains voltage (Vac) 115 / / / / 230 Mains frequency (Hz) 50 / / / / 60 Mains connection 1 phase earthing contact 1 phase earthing contact 1 phase earthing contact 1 phase earthing contact Power input (W) Ultrasonic frequency (khz) Effective ultrasonic output (W) 70 / 120 switchable 100 / 160 switchable 110 / 180 switchable 180 / 300 switchable max. HF constant maximum output (W) Heating output (W) Thermostat control range C C C C Permanent sweep function yes yes yes yes Timer 15 min./constant operation yes yes yes Ja Order no Optional accessories Stainless steel lid (order no.) Stainless steel basket (order no.)
11 6 Technical data Accessories for the JOKE Eco-Clean ultrasonic cleaners 1 Stainless steel lid 2 Basket insert, stainless steel mesh Controls of the JOKE Eco-Clean ultrasonic cleaners 11
12 7 Operation Fig. 7.1 Overview of controls 1 Timer for ultrasound operation. Adjustment options: 1-15 min. for short operation (with automatic switch-off) permanent setting (manual switch-off) 2 Ultrasonic output selection switch for 2 cleaning settings. power: for intensive cleaning and soft: for gentle cleaning of sensitive parts 3 Heating switch 4 Controller for heating thermostat C 5 Ultrasonic control light indicates ultrasound operation 6 Heating control light indicates heating operation 12
13 7 Operation Operation for the first time Before operation for the first time after removing the packaging, check the housing, controls/mains connection cable and the ultrasonic trough for any damage. If damage is observed, the device must not be operated. In this case, inform JOKE customer service. 1. Place the device on a firm, dry base. IMPORTANT! It is essential to prevent penetration of moisture on the underside of the device. Permitted ambient temperature: C. Permitted relative humidity up to 30 C: 80 % Permitted relative humidity up to 40 C: 50 % Misting is not permitted! IMPORTANT! 2. Screw/install the elbow and the drainage hose on to the shut-off cock on the side of the device. 3. Fill the vibration trough with cleaning liquid. Only use cleaning liquid authorised by the manufacturer (JOKE - Clean). WARNING! Never fill the device with inflammable liquids or volatile solvents. This results in a risk of fire and explosion. 13
14 7 Operation wrong right Bild 7.2 IMPORTANT! Fill the vibration trough up to the mark with liquid, but at least to 2/3 however. An excessively low filling level will result in damage to the device. INFORMATION! 4. Connect the device to the power source with the mains cable. The rotary switch for temperature adjustment (7.1/5) must be set to 0 and the switch for the heating must be set to OFF. IMPORTANT! Take care to ensure proper earthing of the socket. 5. Arrange the workpieces in the basket insert or in the vibration trough During each cleaning operation, ensure that the workpiece is completely covered with cleaning liquid. Cleaning is normally performed directly in the vibration trough. Indirect cleaning in inserts or a suspension trough is to be performed when: Using chemically corrosive cleaning liquids (e.g. acids, etc.) Removing chemically corrosive soiling (e.g. cleaning of racks from continuous processors) Removing abrasive soiling (e.g. polishing compound, resin and sand). Cleaning directly in the vibration trough Cleaning only with a basket insert or device container. The object to be cleaned must not stand on the floor of the trough. 14
15 7 Operation Fig. 7.3 Indirect cleaning in inserts or in an unperforated suspension trough Fill the inserts or suspension trough with cleaning liquid (e.g. water + JOKE Clean 225 dispensed). IMPORTANT! Suspend the inserts in the perforated lid. Do not stand them on the floor of the trough. Inserts or the suspension trough must be immersed at least 2 cm deep in the cleaning liquid. In doing so, take care to fill the vibration trough 2/3 full. INFORMATION! Several inserts with different cleaning liquids can be ultrasonicated simultaneously. Bild 7.4 Kontaktflüssigkeit = Contact liquid 15
16 7 Operation Further instructions for the insertion of the goods to be cleaned Place the more heavily soiled side facing downwards. Do not stack parts on top of each other, ultrasound will be absorbed. Sensitive parts must not touch each other. Damage is avoided by using the plastic inserts, the plastic insert basket or the silicon nubbed mat in suspension troughs. Temperature control for heat-sensitive parts. No air bubbles must be present in cavities (e.g. blind holes). Switching the ultrasonic cleaner on and off The device is switched on and off by adjusting the timer. Timer operation 1. Turn the rotary knob (fig. 7.1/1) clockwise to the desired cleaning time (max. 15 minutes). 2. The timer switches off automatically once the preset time is over. 3. The cleaning time can be shortened or the device switched off by turning in the opposite direction. Constant operation 1. Turn the rotary knob (fig. 7.1/1) to the position. 2. The device does not switch off automatically; therefore turn the rotary knob back to OFF in order to switch off. INFORMATION! In the switched off state, the device may remain connected to the mains. Disconnection from the mains is performed by pulling out the mains plug. 16
17 7 Operation Output adjustment The ultrasonic output can be set to soft or power at the rocker switch (fig. 7.1/2). The preselected setting is constantly maintained. Adjustment of the heating 1. Set the rotary selector knob to the desired temperature. 2. Rocker switch in the ON position The white control lamp goes out once the desired temperature is reached. INFORMATION! IMPORTANT! INFORMATION! IMPORTANT! INFORMATION! INFORMATION! The heating functions independently from the ultrasound. Do not switch on the heating without cleaning liquid. There is a risk of burning out. Warmed cleaning liquid intensifies the cleaning. Do not heat disinfection liquids. Ultarsonic energy also warms the cleaning liquid; consequently, simultaneous ultrasonication reduces the heating time. By constant ultrasonication and covering the vibration trough, the liquid temperature may increase to above the preset value. 17
18 7 Operation Heating the cleaning liquid Depending on the soiling, in addition to the assistance of the suitable cleaning medium, it is recommended to heat the cleaning liquid. heating switch in the on position Switch the heating switch on. The yellow control light heating illuminates. Temp. adjustment at the control thermostat Set the desired cleaning temperature. The trough must be at least half full. The optimum filling level is up to the trough mark. In order to achieve uniform heating of the cleaning liquid, it is necessary to occasionally switch the ultrasound on or manually stir the liquid. INFORMATION! Without circulation of the liquid, the heat generated rises to the surface by the influence of physics. A steep temperature gradient results in the cleaning bath (the temperature differences between the surface of the liquid and the floor of the trough may be up to 40 C). Furthermore, increased calcareous deposits form in the heating area, since the resulting high temperature is not optimally dissipated into the liquid. 18
19 7 Operation Duration of cleaning In principle, the shortest possible duration of cleaning is to be set. Depending on the soiling and the cleaning liquid used (comply with the instructions on the respective labels of the cleaning liquids), the duration of cleaning amounts to approx. 1 to 15 minutes. INFORMATION! Degassing the cleaning liquid increases the cleaning effect. Cleaning and contact liquids contain dissolved gases (e.g. oxygen). Ultrasonicate cleaning or contact liquids that have been freshly filled or have remained in the vibration trough for a long period for approx. 5 to 15 minutes before use. Degass vibration troughs of more than 10 l volume for approx. 30 min. During the degassing, the cavitation noise changes, loud degassing noises cease at the end of the degassing process and the device works noticeably more quietly. A lower noise level does not mean any decline in the ultrasonic output, but only the end of the degassing process. Draining the vibration trough Do not place the device in the sink! Devices with a drainage hose The trough is drained by opening the shut-off cock on the side. Before operating the device for the first time, install the elbow supplied and the drainage hose on the shut-off cock. IMPORTANT! After draining the trough, it must be ensured by rinsing several times that there are no particles (> 300 µm) in the drain outlet. 19
20 7 Operation General guidelines for the use of cleaning products The maximum cleaning effect is achieved with media specially suited to ultrasonic use, e.g. JOKE -Clean. Renew used cleaning and disinfection liquids; do not refresh by subsequently adding more. Layers of dirt on the base of the trough or inserts (e.g. grinding and polishing media and other deposits) impair performance; consequently, drain the vibration trough and clean the latter and renew cleaning liquid. Cleaning and contact liquid in the ultrasonic vibration bath must not exceed a maximum operating temperature of 100 C. Distilled or deionised water is unsuitable for ultrasonic cleaning directly in the vibration bath (in insert and suspension troughs, distilled or deionised water is usable both as a cleaning liquid and starting bath for other cleaning products). Only use cleaning preparations tested and developed for ultrasonic cleaning, e.g. JOKE -Clean. CAUTION! During work with corrosive cleaning products in inserts or a suspension trough, avoid projections in the contact liquid or on the stainless steel surfaces; if necessary, immediately renew the contact liquid, clean surfaces and rub dry. No warranty is accepted for damage to the device and instruments caused by use of unsuitable cleaning or disinfection chemicals. 20
21 8 Troubleshooting Finding Possible cause Remedy Housing or mains cable damaged No function; control lights not illuminated No ultrasonic function; Ultrasonic control light not illuminated, heating OK No ultrasonic function; Ultrasonic control light illuminated, heating OK Cleaning result not satisfactory Device does not heat up; Heating control light not illuminated; US can be activated Heat-up time not satisfactory Device generates boiling noises when heating Set temperature is exceeded Outside influence, transport damage Mains plug not connected Socket devoid of current Mains cable damaged / cut Timer not activated Timer faulty Electronics faulty No cleaner or unsuitable cleaning medium used Cleaning time too short Heating switch faulty Control thermostat faulty (no switch click audible) Thermal energy escapes No circulating of the cleaning liquid No circulation of the cleaning liquid Temperature sensor does not record the average temperature (no circulating) Preselected temperature too low Ultrasonic energy heats the liquid (physical process) Send device to JOKE service Insert mains plug Check socket/fuse Send device to JOKE service Set timer to on Send device to JOKE service Send device to JOKE service Use suitable cleaning medium Repeat cleaning interval Send device to JOKE service Use lid (optional accessory) Circulate cleaning liquid e.g. additionally switch on ultrasound (refer to page 17) e.g. additionally switch on ultrasound (refer to page 17) Circulate cleaning liquid Circulate liquid manually or by ultrasound At low set-point temperatures, omit heating Only switch on ultrasound for a short period. 21
22 8 Care and maintenance JOKE ultrasonic cleaning devices are maintenance-free. In order to prolong the service life of the vibration trough and always achieve perfect cleaning results, regular cleaning and care of the device is necessary. Observe the following points for cleaning: INFORMATION! Pull out the mains plug before any cleaning of the device. Do not spray down the devices or immerse the latter in water, but wet wipe the interior and exterior. Thoroughly rinse out and rub dry the stainless steel trough more frequently. Do not use any steel wool and avoid using scrapers. If after more prolonged use, tide-marks remain on the stainless steel surface of the vibration trough, these should be removed with a common commercially available stainless steel care product without any scouring additives. Remains of metal parts on the stainless steel surface in addition to rust particles from the water supply system may penetrate the passive protective surface of the stainless steel, activate the stainless steel and cause it to begin to rust. This foreign rust causes crevice corrosion on the stainless steel. Consequently, remove any metal parts remaining behind, such as screws and metal filings, etc. and remove small rust marks immediately using a soft cloth and common commercially available stainless steel care products. Note on repair All the functions of every device are extensively checked before delivery. If malfunctions occur after prolonged operation, JOKE Service should be contacted. 22
23 10 Cleaning products Cleaning products In the choice of the right cleaning product, it is essential to pay attention to suitability for ultrasonic troughs, since otherwise damage to the vibration trough may occur. Inflammable products are generally not allowed (refer to warnings). The products must not contain any halogenide ions or table salt, since these result in tension cracks in the trough. Acids, such as hydrochloric acid, sulphuric acid or nitric acid will very rapidly destroy the device. Particularly in the case of acid cleaners (e.g. for derusting or removing mineral contamination such as calcareous deposits) only specially formulated cleaners should be used. We offer a comprehensive range of cleaning preparations, which guarantee a long service life for the device. Refer to our current JOKE catalogue in this connection (page 399). If products from other manufacturers are used, please observe the instructions included, specifically concerning use in ultrasonic baths. 23
24 11 Telefax form To the JOKE service department +49 (0) / Sender: Company Name Street Postcode/town or city Please send us the spares drawing and parts list for the following equipment: 0 as a printout (see above for address) 0 by fax, 0 as a pdf file to my address Ultrasonic cleaner Eco-Clean 30HA Ord. No Ultrasonic cleaner Eco-Clean 50HA Ord. No Ultrasonic cleaner Eco-Clean 70HA Ord. No Ultrasonic cleaner Eco-Clean 140HA Ord. No Date Signature 24
25 JOISTEN & KETTENBAUM GmbH & Co. KG Asselborner Weg D Bergisch Gladbach Telefon: / Telefax: / Änderungen aufgrund technischen Fortschrittes vorbehalten Internet: info@joke.de JOKE 07/04
JOKE Basic-Clean. Ultrasonic cleaners. Instruction Manual
JOKE Basic-Clean Ultrasonic cleaners Instruction Manual 1 List of contents 1 List of contents... Page 02 2 Tips on using the manual... Page 03 3 Safety instructions... Page 04 4 Warranty... Page 06 5 Device
More informationCompressed-air grinder. AirMAX 230F. Instruction manual
Compressed-air grinder AirMAX 230F Instruction manual 1 List of Contents 1 List of contents... Page 02 2 Tips on using the manual... Page 03 3 Safety instructions... Page 04 4 Warranty/Identification...
More information+ English + 1. Safety warnings
1. Safety warnings Carefully read the safety warnings before you operate the unit. The present ultrasonic cleaning unit has been designed for the ultrasonic treatment of items and liquids only. The unit
More informationOperating Instructions
Operating Instructions Elmasonic E Ultrasonic Cleaning Units english Elma Schmidbauer GmbH Gottlieb-Daimler-Str. 17 D-78224 Singen Phone +49 (0)7731 / 882-0 Fax +49 (0)7731 / 882-266 info@elma-ultrasonic.com
More informationCompressed-air filing machine LFC 10. Instruction manual
Compressed-air filing machine LFC 10 Instruction manual 1 List of Contents 1 List of contents... Page 02 2 Tips on using the manual... Page 03 3 Safety instructions... Page 04 4 Warranty/Identification...
More informationCleaning systems Overview
. Cleaning systems Cleaning systems Overview 424 Ultrasonic cleaning units 434 Cleaning products for ultrasonic cleaners 422 Tel. +49 (0) 22 04 / 8 39-0 Fax +49 (0) 22 04 / 8 39-1 info@joke.de . Cleaning
More informationOPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:
OPERATIONAL & INSTRUCTION MANUAL Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine: L1 to L2: L1 to Ground: L2 to Ground UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255
More informationOperating Instructions
Operating Instructions Elmasonic P Ultrasonic Cleaning Units english Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-ultrasonic.com www.elma-ultrasonic.com
More informationCavitator Ultrasonic Cleaner Instruction Manual Model 20G
Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationOperating Instructions
Operating Instructions Modular Cleaning System SW60 / 150 / 240 MOD english Sonoswiss G _Modulrange_SW60/150/240_Sonoswiss_E_08.2012 Contents Contents... 1 1 General... 2 2 Important safety warnings...
More informationOperating Instructions
Operating Instructions TECHSPAN S Ultrasonic Cleaning Units english TECHSPANGROUP Australia: Ph: 1-800 148 791 Fax: 1-800 148 799 New Zealand: Ph: +64 9 827 6567 Fax: +64 9 827 6596 sales@techspanonline.com
More informationOperating Instructions
Operating Instructions Ultrasonic Cleaning Units Transsonic TI-H english Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-germany.com www.elma-germany.com
More informationOPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)
OPERATIONAL & INSTRUCTION MANUAL Model: 2400FA (120v 1Ø) UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255 Tel: 513-502-9746 Fax: 513-702-2399 info@ultrasonicllc.com www.ultrasonicllc.com SAFETY REQUIREMENTS
More informationCavitator Ultrasonic Cleaner Instruction Manual
Cavitator Ultrasonic Cleaner Instruction Manual Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationOperating Instructions
Operating Instructions Elmasonic S Ultrasonic Cleaning Units english Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-germany.com www.elma-germany.com
More informationOperating Instructions
Operating Instructions Elmasonic S Ultrasonic Cleaning Units english Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-germany.com www.elma-germany.com
More informationCavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual (for model # 18G) 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationRead these instructions before using and keep them available at all times!
200065 V2/0614 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about
More informationCleaning systems Overview
. Cleaning systems Cleaning systems Overview You have the cleaning tasks, we have the appropriate solutions. Our cleaning systems cover the whole spectrum of industrial part cleaning: Using the joke BioCleaner
More informationCleaning systems Overview
. Cleaning systems Cleaning systems Overview You have the cleaning tasks, we have the appropriate solutions. Our cleaning systems cover the whole spectrum of industrial part cleaning: Using the joke BioCleaner
More informationAirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Operating manual List of contents, Operating manual Page 1. General information... 02 2. Device description... 03 3. Adjustment
More informationBefore digging into the 10 things you should know let s start with a brief explanation of the process.
Ultrasonic cleaners are unsurpassed when it comes to removing contaminants from virtually any hard surface that can be safely immersed in a cleaning solution. The challenge is selecting the correct ultrasonic
More informationElectrostatic Precipitator
Electrostatic Precipitator ESP1500E ESP3000E ESP4500E TECHNICAL & OPERATION MANUAL This manual refers to:- Model ESP1500E Serial No. E152014 Model ESP3000E Serial No. E302014 Model ESP4500E Serial No.
More informationContents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.
Contents Contents... 1 Safety Instructions... 1 Installation... 3 Quick Guide... 4 Manual I Control Panel Instructions (U50, U95, U100, U300)... 6 Manual II Control Panel Instructions (U100H)... 7 Manual
More informationInstruction Manual for Bench-Top Cleaning Baths
Precision Ultrasonic Cleaning Equipment Instruction Manual for Bench-Top Cleaning Baths 1 Oxford Street, Cardiff, CF24 3WY United Kingdom Telephone Sales: 0845 330 4236 Telephone Service: 0845 330 4238
More informationManual Page 1 of 8. Manual. Laboratory autoclave
Manual 17.11.2014 Page 1 of 8 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav
More informationUser Manual Watt Drop-In Induction Range. Model: DC /2017. Please read and keep these instructions. Indoor use only.
1800 Watt Drop-In Induction Range Model: DC1800 08/2017 Please read and keep these instructions. Indoor use only. www.avantcoequipment.com 1 Specifications Model No... DC1800 Power Rating... 500-1800W
More informationULTRASONIC CLEANERS INSTRUCTION MANUAL MODELS
vwr.com 1.800.932.5000 ULTRASONIC CLEANERS INSTRUCTION MANUAL MODELS 97043-930, 97043-932, 97043-934, 97043-936, 97043-938, 97043-940, 97043-942 97043-944, 97043-946, 97043-948, 97043-950, 97043-952, 97043-954,
More informationUltrasonic cleaning Ultrasonic cleaning devices. Ultrasonic cleaning devices. Edition 5
Fundamentals: Ultrasonic cleaning is one of the most modern cleaning methods. It achieves maximum cleanliness of the treated parts, even in places which are difficult to access, while being extremely gentle
More informationRead these instructions before using and keep them available at all times!
A120407 V4/0713 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about
More informationResidential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...
70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................
More informationGlass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:
Glass and Dishwashers ECOMAX 402/452/502 (incl. Australian 452-90/502) INSTALLATION AND OPERATION INSTRUCTIONS (original instructions) Starting from Serial No.: 8663 4000 REV. 05.10.2015 EN IMPORTANT NOTES
More informationOPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN
OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill
More informationCavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com email:
More informationElmasonic S Ultrasonic cleaning units. The sum of all possibilities
Elmasonic S Ultrasonic cleaning units The sum of all possibilities Electronic time and temperature control Autostart temperature-controlled / temperature pre-selection High-performance transducer systems
More informationJT-SB116JH-G-NA JT-SB116JH-W-NA
1311875HF4503 Hand dryer MODEL JT-SB116JH-G-NA JT-SB116JH-W-NA Unit color -G (Grey), -W (White) Model Name Display Position. Power voltage display position. INSTRUCTION MANUAL For User Read this manual
More informationUSER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES
USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460 2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION
More information14/06/058-V1 USER GUIDE ULTRA 7000S ULTRASONIC CLEANER
14/06/058-V1 USER GUIDE ULTRA 7000S ULTRASONIC CLEANER INTRODUCTION Use tap water. Special solutions are not necessary in most cases. Principles of ultrasonic cleaning: Millions of tiny air bubbles are
More informationOperating Instruction
Version 0 21/02/2017 Operating Instruction Hot air dryer english Item No. 108 3106 Elma Schmidbauer GmbH Gottlieb-Daimler-Str. 17 D-78224 Singen Tel. +49 7731 882-0 Fax +49 7731 882-266 info@elma-ultrasonic.com
More informationOperating Instructions
Operating Instructions Elmasonic X-tra basic Ultrasonic Cleaning Units english Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-ultrasonic.com
More informationSkymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual
Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual Model: JP-360ST and JP-300ST Please read the manual carefully before operation. 1 INDEX 1. Working conditions. 3 2. General..
More informationTrotec PAC FT 2600 Portable air conditioner
Trotec PAC FT 2600 Portable air conditioner The PAC FT 2600 portable room air conditioner comes with an infrared remote control and an air outlet hose with a flat nozzle.the unit s primary function is
More informationLABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F
0 LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F WITH WEST 6100 CONTROL 1 IMPORTANT INFORMATION This manual contains operating
More informationOmegasonics. Ultrasonic Cleaning Equipment Operation & Instruction Manual
Omegasonics Ultrasonic Cleaning Equipment Operation & Instruction Manual OMEGASONICS Table Top Unit 2017 and After Model 7850TT / 7950TT Read all instructions thoroughly before operating this equipment
More informationTurbo Sonic Raytech. Ultrasonic Cleaner. Operating Instructions
SPECIFICATIONS Description Digital Ultrasonic Cleaner Model TS-6000 Item No. (115V) 7631725 (230V) 7631726 Tank Size 12.7 x 8.0 x 3.9 in. 32.3 x 20.3 x 9.9 cm Longest item that can fit in tank 13.4 / 34.0
More informationBarAid 400. Installation and. Starting from Serial No.:
Glasswasher BarAid 400 Installation and operation Instructions Starting from Serial No.: 8649 1065 REV. 19.01.2009 DE 1618-A-01-09 Content Page 1 Important Notes... 4 2 Installation... 5 2.1 Location...
More informationMW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance
MW001 Integrated Dishwasher Manual for Installation, Use and Maintenance Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.
More informationINSTRUCTIONS CertoClav EL
High Pressure-LABORATORY AUTOCLAVE Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization As an aid in research and development Thermometer Lid handle with locking
More informationHX-30/40 and HX-30/40 S Glass and Dishwashers
HX-30/40 and HX-30/40 S Glass and Dishwashers INSTALLATION OPERATION VERSION 18/01/00 2 Installation and Operation Instructions for Model HX-30/40 and HX-30/40 S (with built-in softener) Content Page 1
More informationINSTALLATION AND OPERATING INSTRUCTIONS DÜRR DAYLIGHT LOADER DL 24, DL 26, DA 24
INSTALLATION AND OPERATING INSTRUCTIONS DÜRR DAYLIGHT LOADER DL 24, DL 26, DA 24 2005/05 2 CONTENTS Important Information 1. Notes... 4 1.1 Conformity... 4 1.2 General Notes... 4 1.3 General Safety Notes...
More informationFundamental safety warnings
INTRODUCTION Read these instructions carefully before using the appliance. Failure to follow these instructions may result in injuries and equipment damage. The manufacturer is not liable for damages resulting
More informationOperating Instructions
Operating Instructions Clinical Autoclaves P3 - Decals, displays and controls P4 - Introduction - Key to Pictures P5 - Getting Started P6 - Continued Operation P7 - Troubleshooting P8 - Technical Specification
More informationVmusbtpojd!dmfbojoh!xjui!tubuf.pg.uif.bsu!ufdiopmphz
Vmusbtpojd!dmfbojoh!xjui!tubuf.pg.uif.bsu!ufdiopmphz Ultrasonic transducer systems Sweep Degas and Autodegas The Elmasonic S ultrasonic units offer practically every available technical feature. Now the
More informationQuickStart Guide. Automated Support Removal System. PostProcess Technologies, Inc. REV C
CENTI QuickStart Guide Automated Support Removal System PostProcess Technologies, Inc. www.postprocess.com REV C Copyright Copyright 2018 by PostProcess Technologies Inc. POSTPROCESS. All rights reserved.
More informationGlass and Dishwashers AMX / AUX Series
Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION REV. 8.xx 04.07.2005 Installation and Operation Instructions for Models of AMX / AUX Series Content Page 1 Installation... 3 2 Connections...
More informationOperating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions
Operating Instructions Accessory Units Melitta Cafina XT Series Melitta Professional Coffee Solutions Contents General... 4. Manufacturer information... 4.2 About these instructions... 4.3 Explanation
More information8 LITRE URN. Instruction Booklet. Please read these instructions carefully and retain for future reference
8 LITRE URN Instruction Booklet Please read these instructions carefully and retain for future reference EJ8400 Contents Sunbeam s Safety Precautions 1 Features of your Café Series Urn 2 Using your Café
More informationWC600 Integrated Dishwasher Installation, Use and Maintenance
WC600 Integrated Dishwasher Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu
More informationOWNERS MANUAL ELECTRIC STOVES
OWNERS MANUAL ELECTRIC STOVES Electrolux Home Products 1. READ these instructions carefully before installing and operating the oven. Keep them for further reference. 2. Record in the space below the MODEL
More informationFHA 1100 A1 Domestic Water Pump
FHA 1100 A1 Domestic Water Pump Translation of original operation manual 6 Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device. / Translation
More informationBUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set.
BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number
More informationthe Compact Kettle Instruction Book - BKE320BSS
the Compact Kettle Instruction Book - BKE320BSS Contents 2 Sage Recommends Safety First 6 Components 7 Functions 8 Care & Cleaning IMPORTANT SAFEGUARDS At Sage by Heston Blumenthal we are very safety conscious.
More informationK Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.
K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............
More informationUltrasound cleaning Product catalog
Ultrasound cleaning Product catalog English VORWORT Since 1990 we are involved in developing innovative ultrasound technology. Apparently we had the right vision that ultrasound technology is an important
More informationMW402 Integrated Dishwasher
MW402 Integrated Dishwasher Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu
More informationInstallation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro
Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2
More informationIreland. Australia. New Zealand
UK Ireland Australia New Zealand 2 3 4 5 Intended use Your Black & Decker vacuum cleaner has been designed to vacuum dry substances. This product is intended for household use only. Safety instructions
More informationAustralia. New Zealand
.... Australia New Zealand 2 5 3 4 JA JB JC JD JE JF JG JH JI JJ JK JL JM JN JO 5 Intended use Your Black & Decker vacuum cleaner has been designed to vacuum dry substances. This product is intended for
More informationCool Mist Ultrasonic Humidifier
Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information HUM-CM50 IMPORTANT SAFETY INSTRUCTIONS: WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS
More informationWelcome to. KUDOS Technology in Ultrasonic Cleaning. Applications of KUDOS ultrasonic cleaners
Welcome to KUDOS Technology in Ultrasonic Cleaning KUDOS takes pride in supplying the highest quality ultrasonic cleaners worldwide. As a leading manufacturer in the ultrasonic technology, KUDOS announces
More informationSteam Trap BK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...
More informationUser Manual Watt Drop-In Induction Range. Model: ID18DB 08/2017. Please read and keep these instructions. Indoor use only.
3100 Watt Drop-In Induction Range Model: ID18DB 08/2017 Please read and keep these instructions. Indoor use only. www.avantcoequipment.com 1 Specifications Model No... ID18DB Power Rating... Front: 500-1300W,
More informationIMPORTANT SAFETY INFORMATION
319252GB.fm Page 11 Wednesday, September 3, 28 4:5 PM IMPORTANT SAFETY INFORMATION This manual contains important information regarding safety, the use and maintenance of your new hob. Read the manual
More informationWITH OMRON E5CC CONTROL
LABORATORY OVENS, FAN FORCED & GRAVITY CONVECTION. MODELS: TO-152G & TOH-152G TO-152F, TOH-152F & TO-235F TO-330F & TO-500F WITH OMRON E5CC CONTROL Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline
More informationPLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.
File name: ARDI Care & Use Manual.pub Last revised: Oct 10th 2008 PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. ASSEMBLER / INSTALLER Leave
More informationInstructions For Use ENG. LED Magnifier Lamp
Instructions For Use ENG OPTICA 488 LED Magnifier Lamp ENG Table of Contents 1. For your safety...3 1.1 Designated use...3 1.2 Safety instructions...3 1.3 Warning levels...4 2. Mounting...4 2.1 Mounting
More informationI N S T R U C T I O N S
INSTRUCTIONS HIPPO Deluxe Room Steam Vaporiser Congratulations on your purchase of the HIPPO Deluxe Room Steam Vaporiser. Before using this appliance, read the following instructions carefully as they
More informationIllustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278
Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation
More informationIs Your Ultrasonic Cleaning System Living Up to Its Potential?
Is Your Ultrasonic Cleaning System Living Up to Its Potential? Some guidelines about ultrasonic cleaning equipment and performance. The use of ultrasonic cleaning equipment to clean or degrease parts has
More informationIMPORTANT SAFETY INSTRUCTIONS DANGER WARNING
IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: www.whirlpool.eu YOUR SAFETY AND THAT OF OTHERS IS VERY IMPORTANT This manual and the appliance itself provide important
More informationHigh-power ultrasonic cleaner
High-power ultrasonic cleaner Typical Industrial Application Automobile Industry Cleaning of injection nozzles, carburetors, spray guns, nozzles, shock absorbers, engine parts, circuit boards and cutting
More informationInverter Split-type Room Air Conditioner
OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
More informationStatClean - Ultrasonic Cleaner
StatClean - Ultrasonic Cleaner USER MANUAL FEATURES: Large Tank Capacity Large Tank Capacity Control panel with capacitive sensing technology Drainage valve Tank capacity 6.0 L / 1.6 gallon. Tank size:
More informationOperating Instructions
Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. 5.962-066.0 02/07 Dear Customer, Please read and comply with these instructions prior
More informationINSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE
INSTRUCTIONS Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES MODELS Full-Service Humidified Full-Service Self-Service HD3 HD4 HD5 HD7 HD3 HD4 HD5 HD7 HD3 HD4 HD5 MODEL HD5 Full-Service
More informationEssentials Family and Pets+ permanent bagged cylinder vacuum cleaner
70255 rev1 12/9/07 09:49 Page 1 Essentials Family and Pets+ permanent bagged cylinder vacuum cleaner Please read and keep these instructions Getting the best from your new cleaner... If your cleaner is
More information1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER
Adorable Humidifiers 1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER FOR THE FOLLOWING MODELS: EE-0865 EE-3186 EE-3189 EE-3190 EE-3191 EE-4139 EE-4140 EE-5058 EE-6369 EE-7270 EE-8189 EE-8190 EE-8243 If you
More informationPROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction
PROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction Read all instructions before using this appliance -1- For your safety please read owners manual in its entirety before use. Congratulations
More informationThe guarantee on this appliance is valid for 12 months from the first day of installation.
Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations
More informationEN Bagged Vacuum Cleaner
SVC 8500TI EN Bagged Vacuum Cleaner - 1 - EN Bagged Vacuum Cleaner Important safety instructions READ CAREFULLY AND STORE FOR FUTURE USE. This vacuum cleaner may be used by children 8 years of age and
More informationFOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.
Droplet Humidifiers FOR THE FOLLOWING MODELS: EE-5302 EE-5302A EE-5302W If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care. Toll Free: 888-599-0992
More informationDual Tank Deep Fryer. Use and Care Instructions. Double Capacity Twice the Power Easy Cleanup
Use and Care Instructions Dual Tank Deep Fryer Double Capacity Twice the Power Easy Cleanup 1. Removable 1700Watt X 2 dual elements heat oil faster and recover to cooking temperature sooner 2. Both 3.0
More informationUL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI
ULTRASONIC SCALER PIEZO MINI CONTENTS XI - SYMBOLS 1. INTRODUCTION 1 Alternating current Type BF device 2. WARNINGS 1 3. PRESENTATION 1 3.1 Presentation 1 3.2 Technical description 2! Warning, please refer
More informationResidential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...
Residential Gas Condensing Boiler Greenstar combi 00 p / 5 p ZWB8-3A... ZWB4-3A... Operating Instructions 708733 (07/04) US/CA Contents Contents Explanation of symbols and safety instructions.......................
More informationIreland. Australia. New Zealand
UK Ireland Australia New Zealand 2 3 4 5 Intended use Your Black & Decker vacuum cleaner has been designed to vacuum dry substances. This product is intended for household use only. Safety instructions
More informationFTA-1 Aspirator with trap flask
Medical Biological Research & Technologies FTA-1 Aspirator with trap flask Operating Manual Certificate for version: V.4AW 2 Contents 1. Safety Precautions 2. General Information 3. Getting Started 4.
More informationBRANSONIC Bransonic Baths
BRANSONIC Bransonic Baths The simple, reliable solution to quality precision cleaning BRANSON: A Recognized Leader in Ultrasonics Worldwide For over 60 years, Branson has been the leader in the development
More informationLABORATORY ILLUMINATED FLOTATION BATH
LABORATORY ILLUMINATED FLOTATION BATH MODELS INCLUDE: TFB-1 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 6862 Wetherill Park DC NSW 1851
More informationMW401 Integrated Dishwasher
MW401 Integrated Dishwasher Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu
More informationOPERATING INSTRUCTIONS
EN OIL FILLED RADIATOR OPERATING INSTRUCTIONS Read the instructions carefully before operating the panel or carrying out maintenance operations. Observe all the safety instructions; failure to observe
More information