MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Size: px
Start display at page:

Download "MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER"

Transcription

1 MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

2 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make sure that the unit can physically fit in to the desired location. The MEV Spider unit should be situated so that access for maintenance or replacement of parts is possible. Make the ductwork runs as short as possible. Having the most direct route and using as few bends as possible will reduce air resistance and improve the efficiency of the unit. SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a qualified electrician. Precautions must be taken to avoid the back-flow of gases into the dwelling from the open flue of gas or other fuel-burning appliances. Make sure the mains supply complies with the rating label for voltage, frequency and phase. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 1 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON:

3 Wiring Electrical Connections The appliance must be earthed and a double pole switch having a minimum contact separation of 3.0mm must be used to provide isolation for the unit. All wiring must be completed by a qualified electrician. This appliance is suitable for 230V ~ 50Hz single phase supply fused at 3 amps. The appliance is supplied with a 3 core mains flexible cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Emergency Shutdown Details Unit to be isolated from the mains by turning it off at the isolating point. Wiring Diagrams Remote control version (MEVS-W) Humidity version (MEVS-H) After Sales Service We recommend you do not dismantle or remove any other parts than those mentioned, as any tampering would automatically cancel the guarantee. If you detect any fault please contact EnviroVent. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 2

4 Technical Specifications Dimensions Supply Voltage 230V / 50-60Hz / 70W Max / 0.5 A Max Ø Dimensions H 198mm x W 440mm x D 198mm Ventilation Capacity Weight pa. Max 151 l/s (545m 3 /h) Boxed 5.8kg Unit 4.3kg Performance Curve 3 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON:

5 Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore ensure that this product is treated with care and installed properly i.e. for the life of the building. If the unit is mishandled you might break it! This invalidates the warranty. And remember, if you have any problems please call our dedicated Technical Team. We are always pleased to help and in an emergency will come out to site quickly, completely free of charge. About the unit The EnviroVent MEV Spider is a low-energy, continuous mechanical extract ventilation system designed with multiple extract points to simultaneously draw moisture-laden air out of the wet rooms, whilst minimising the migration of humidity to other rooms. The extract unit is centrally located in, for example, a hallway cupboard, with ducts running from the unit to the kitchen, bathroom, en-suite and other wet zones. The unit is suitable for houses, apartments and communal residences with kitchen plus up to 6 additional wet rooms, providing high centrifugal performance with low running noise. Highly cost effective and value for money, the MEV Spider comes with a full five year guarantee. Exploded view Lid Commissioning panel Electronics assembly Fan scroll and fan Ø100 input Black box Ø125 spigot extract to atmosphere Made in Harrogate UK AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 4

6 Box Contents Description Quantity Item MEV Spider Unit 1x Spigots 3x Spigot Blank 1x Fixing Kit 1x - Screw 8G X 2.0 4x - Washers 4x - Plasterboard Plugs 4x - Adhesive Foam Pads 8x - Rubber Sleeve 4x 5 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON:

7 Installation Instructions Mounting the unit 1. The unit maybe installed in any vertical or horizontal orientation. 2. Use the unit as a guide to mark fixing holes on the mounting surface ensuring clearance around the MEV unit. Drill 4 x Ø8mm holes, position wall plugs in the mounting surface and foam pads on the back of the unit s mounting tabs. 4. Attach fixings 5. Secure the MEV unit on all four corners. 3. Side view of fixings. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 6

8 Installation Instructions Connecting the ductwork 1. Scribe around the outer edge of the required spigot blank MAX x 3 (a). Knock out the blank with a light tap (b). 4. Push in spigot and fix with self tapping screws provided. (a) (b) 2. Remove blanks from inside the unit. 5. Ductwork, ridged and flexi must be securely fixed. 3. It may be necessary to remove excess material with a knife. 6. If a blank is removed in error, the spigot hole must be filled with the spare blank provided. Firmly glue in place. To connect unit to mains supply, see pages MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON:

9 Controls Intellitrac Humidity Tracking (Automatic) When the MEV unit senses a rise in humidity, caused by increased moisture generation such as through cooking or showering, the extract and supply airflows will slowly begin to increase in direct proportion to the increase in humidity. It will then automatically track back down again when humidity falls. This controls condensation quietly and efficiently. Boost - Wall Switch The MEVS-H comes with a boost switch as standard to activate boost when required. The unit will remain at boost for as long as the switch is on. Boost - Remote Control The MEVS-W unit comes with a remote control switch to activate boost. The unit remains at boost for 20 mins. See page 9 for further information. Commissioning Boost controls The MEV Spider operates continuously on Normal setting to ensure the home is ventilated at the appropriate level although you can boost the system via the wired or remote control switch, if fitted. For remote control switches, press the button once, the green LED will light up and the unit will go to boost. The boost time is set to 20 minutes as standard. Batteries When the battery requires changing, unscrew the switch front cover. The battery is located on the back of the cover. Battery type - 3V Lithium, CR2032. Ensure that the new battery is inserted with the correct polarity and that the exhausted battery is removed and safely disposed of. To pair additional remote control switches (wireless units only) 1. Turn the unit off at the isolation point. 2. Restore power; for 20 seconds from restart the unit will be in pairing mode. 3. Press the remote button once within the 20 seconds and the control will pair to the unit. 4. Successful pairing is indicated by a green light on the control. Remote control Flashing red LED = not paired Constant green LED = paired Remote control button AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 8

10 Commissioning Setup guide for the MEV Spider The control switch is found behind the front cover. Commissioning mode is chosen by pressing the SET button for 4 seconds, all sensor inputs will be disabled in this mode so that they do not interfere with flow rates. LEDs will light with the Trickle flashing, this indicates that the flow rate may now be increased/ decreased as required. The next press of the SET button will move commissioning to the next setting, Boost. When the unit has been fully commissioned, press the SET button for 4 seconds and this will put the unit back into status mode. If the unit is not put back into status mode after commissioning, it will automatically revert back to status mode after an hour or if the power is turned off. Note: Settings will be retained if the power supply is interrupted. LED Indications Constant LED Flashing LED B - Humidity C - Boost State B - Service required Boost and trickle LED indications Commissioning mode only 9 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON:

11 Commissioning Commissioning of a continuous running Multiple Extract Ventilation system - MEV Commissioning of the system is necessary to provide adequate ventilation to the dwelling, as stipulated in Approved Document F (ADF) of the Building Regulations* Conditions All maintenance and development works should be completed prior to the commissioning of the unit, this is to avoid high levels of dust being drawn into the system and general disturbance to the setup. The unit should only be commissioned when fully installed, with power, ductwork, valves and vents in place. See Domestic Ventilation Compliance Guide. Equipment required Anemometer which is capable of measuring l/s or m³/hr. Commissioning method Once the previous conditions are met, boost and trickle rates need to be set. These should be set as outlined in the commissioning guide (pages 8-9). Ensure all internal & external windows and doors are closed. Required background vents are in the open position. See relevant guides. Commissioning guide Boost rate (minimum high rate) Determine the whole building extract ventilation rate. See ADF of the Building Regulations. Open ceiling/wall valves. Measure all extract points summing the individual room rates. Measurements to be carried out with an appropriate anemometer. Adjust using and buttons, press up or down until the total extract rate is met. See the individual product s instruction guide for method (pages 8-9). When the desired overall extract rate is achieved, the individual valves should then be adjusted to draw the appropriate volume of air from each room, typically starting with the largest extract requirement first: kitchen, bathroom, utility room, en-suite and WC. It may be necessary to adjust the fan unit slightly to account for increased pressure. When adjustments are completed the valves should be locked into position to maintain settings. Trickle rate This should be set to the whole building ventilation rate. See ADF of the Building Regulations. As the valves have been commissioned at boost they will not need to be altered further, the trickle buttons should be adjusted up or down, until the lower extract rate is met. See the individual product s instruction guide for method on pages 8-9. For guidance on good installation practice for MEV systems see the latest edition of the of the Domestic Ventilation Compliance Guide*. This guide provides in depth information on all aspects installation, inspection, testing and commissioning. *Applicable in England and Wales. For other countries please refer to your local building regulations. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 10

12 Checklist Checklist to ensure Guaranteed Installed Performance MEV Spider installation instructions have been understood Ductwork to the unit is Ø100mm or larger, from the unit is Ø125mm or larger. No more than 10% flexi used (90% rigid) Duct in unheated areas is insulated All ducts, vents and diffusers are securely connected & sealed The unit is securely fixed into position with enough space left for servicing All major building works have been completed prior commissioning Unit has been commissioned to meet Part F of the Building Regulations with a calibrated anemometer Commissioning data has been recorded Inform building owner/user on how to operate and maintain the system These checks are required to ensure the proper function of this unit. For EnviroVent Technical help call MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON:

13 Maintenance There are no special requirements for any maintenance within a five year period. The unit is easy to clean by simply removing the lid and motor plate. After carrying out work, make sure all the screws are in place. Cleaning Isolate the unit from electrical mains supply before removing any cover, or servicing the unit. 1. Remove 4 screws on top of the lid. 2. Remove 4 screws on top of motor plate. Pull backwards from the spigot and then lift up. Motor mounting remains attached to the main case via cabling. 3. After maintenance replace all components and fixing screws. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 12

14 Warranty Conditions & Exclusions The EnviroVent MEV Spider is covered by a full 5 year warranty which will benefit the occupier over many years. The unit will be set according to the size of the property and will operate continuously. There is no requirement for any maintenance within the 5 year period. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your MEV Spider is not working correctly, you can telephone (operational from 8:00am to 5:00pm Monday to Friday), and ask for technical assistance. You will either be given guidance over the telephone, or an arrangement will be made for an engineer to visit. In any event, please have the following information ready. This will enable your call to be dealt with quickly and efficiently. Please note that proof of purchase by the way of a receipt is required and that any fans bought from an unapproved source, including but not limited to Ebay, will render the guarantee invalid. Serial number of the unit We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. We are confident that you will be delighted with the performance of the system and the resulting improvement in air quality in your home after the installation of the unit. Your warranty covers any defect or break down that arises due to faulty materials or construction. Terms of Warranty The system must be correctly installed and operated according to the instructions contained in the user guide supplied. The warranty will be rendered invalid if the system has been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by EnviroVent Ltd. The warranty will be rendered invalid if the unit is turned off. Turning the unit off can damage it. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The guarantee will only be honoured from approved suppliers. 13 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON:

15

16 Delivering innovative and sustainable ventilation solutions worldwide EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA T / F / E / info@envirovent.com W / envirovent.com Please read carefully to ensure simple installation and a long trouble free life for the user. AFTER INSTALLING THIS FAN PLEASE PASS ONTO END USER DO NOT THROW AWAY E&OE MKT ENV230-V Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice. We want to hear from you Your feedback is important to us as we strive to improve our products, services, and overall customer experience. Please us to help us serve you better: feedback@envirovent.com

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent Contents 01 Introduction 2 02 Technical Specification 3-4 03 Wiring Diagrams 5-6 04 Safety 7-8 05 Controls 8 06 Box Contents 9 07 Tools Checklist 10 08 Installation Steps 11 09 Installation 12-22 10 RF

More information

Wiring the fan correctly...

Wiring the fan correctly... You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. 01 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall, ceiling, inline or window mounted You must ensure that any emissions

More information

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER ECo 2 INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST The ECO

More information

November This product has been reconfigured Please read these instructions

November This product has been reconfigured Please read these instructions November 2013 This product has been reconfigured Please read these instructions Contents Page 01 Introduction 2 02 Box Contents 3-4 03 Tools Checklist 5 03A Pre-Installation Checklist 6 04 Controls 6 05

More information

Wiring the fan correctly...

Wiring the fan correctly... You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore

More information

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5 230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall,

More information

ECo 2 Wall USER GUIDE FOR RESIDENT

ECo 2 Wall USER GUIDE FOR RESIDENT ECo 2 Wall USER GUIDE FOR RESIDENT USER GUIDE About your Mr Venty ECO 2 Wall DO YOU KNOW WHAT S GOING ON IN YOUR OWN HOME? MOISTURE The typical household creates around 100 pints per week - from showers,

More information

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER Made in Harrogate UK Thank you for choosing EnviroVent The fastest growing ventilation company in the UK. You are about to install

More information

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref. Lo-Carbon MULTIVENT MVDC-MS & VENTILATION SYSTEMS Installation and Wiring Instructions Stock Ref. N MVDC-MS 76A 98 0-0V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE

More information

Watch the heatsava video

Watch the heatsava video 01 heatsava Benefits 02 What is the heatsava? 03 How does the heatsava work? Watch the heatsava video 04 Exploded view 05 Controls 06 Cleaning 07 Servicing 08 Guarantee Scan the QR code to watch the video

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

KUDOS. Instruction leaflet

KUDOS. Instruction leaflet KUDOS Instruction leaflet KUDOS RAGE CETRIFUGA EXTRACTOR FAS Suitable for bathroom, kitchen and utility room applications Thank you for placing your confidence in EnviroVent by buying this product. It

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

CMX-S. Company name: Contact: Tel:   Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions V EN T IL AT ION V EN T IL AT ION CMX-S Installer contact details: Company name: Contact: Tel: Email: Central Mechanical Extract Ventilation (cmev) appliance Installation and Operating Instructions These

More information

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High Efficiency Whole House Heat Recovery System Joining the high efficiency energisava

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Installation, Maintenance Instructions and User Guide Unit 6 Chiltonian Industrial Estate 203 Manor Lane, Lee, London. SE12 0TX Tel: 08451 60

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation

More information

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX Green Line CMX Central Mechanical Extract Ventilation (cmev) appliance Installation and Operating Instructions Model: CMX These instructions must be given to the householder DO NOT SWITCH OFF THE UNIT

More information

CLASSIC-100. Instruction leaflet. Instruction leaflet

CLASSIC-100. Instruction leaflet. Instruction leaflet CASSIC-100 Instruction leaflet Instruction leaflet CASSIC-100 AXIA EXTRACTOR FAS Suitable for bathroom applications Thank you for placing your confidence in EnviroVent by buying this product. It has been

More information

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600 I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d Model code: BORA600 Contact Caple on 0844 8003830 or for spare parts www.4caple.co.uk 1 Y O U R A P P L I A N C E Thank you for buying your

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

ECO dmev Decentralised MEV

ECO dmev Decentralised MEV ECO dmev Decentralised MEV The ECO dmev has been designed and developed to offer the market a constant volume, continuously running decentralised extract fan to achieve the lowest power consumption, the

More information

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Installation and Maintenance Instructions Retain for future reference 3. To remove the impeller, unscrew the central screw with a 7mm nut runner

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside Installation and Maintenance MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts. FAT2000/R ow Energy Positive Input Ventilation Unit Installation and Maintenance The EMC Directive 204/0/EU The ow Voltage Directive 204/5/EU.0 ITRODUCTIO The uaire Drimaster/Flatmaster range has been

More information

Introducing the RetroVent

Introducing the RetroVent Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. Eclipse Installation and Wiring Instructions Models Eclipse 100X Eclipse 100XP Eclipse 100XT Eclipse 150X Eclipse 150XP Ref No. 42 73 10A 42 72 81A 42 72 82A 42 72 83A 42 73 13A 220-240V~50Hz PLEASE READ

More information

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2 INTEGRA PLUS Installation and Wiring Instructions Stock Ref. N INTEGRA PLUS 437666 230V~ 50Hz ABC PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX2 VENT-AXIA

More information

INSTALLATION INSTRUCTIONS USER GUIDE

INSTALLATION INSTRUCTIONS USER GUIDE INSTALLATION INSTRUCTIONS USER GUIDE Tilted wall cooker hood HT90GHB2 model GB IE CONTENTS Introduction 3 Safety and warnings 4 Installation instructions 8 About your cooker hood Energy efficiency 18

More information

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 High Efficiency Whole House Heat Recovery Systems Providing all year round good indoor

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18, HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18, 29-20. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL Product Serial Number: Please leave this manual with the end user. Part Number: 1370065 heatingthroughinnovation.

More information

60cm Integrated Turbo Extractor

60cm Integrated Turbo Extractor 60cm Integrated Turbo Extractor LAM2201 User & Installation Guide Dear Customer, Congratulations on your choice of domestic appliance which has been designed to give you excellent service. The user manual

More information

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide Commissioning and Inspection Record: Located on page 10 of this guide, should have been completed by the

More information

Lo-Carbon SELV Tempra

Lo-Carbon SELV Tempra Lo-Carbon SELV Tempra THROUGH THE WALL HEAT RECOVERY FAN Installation and Wiring Instructions DRAFT Stock Ref. N 444368 Pullcord. (SVP) 444369 Timer. (SVT) 444370 Humidistat -Timer Pullcord. (SVHTP) 220-240V~50Hz

More information

ART cm Island Curved Glass

ART cm Island Curved Glass ART28101 90cm Island Curved Glass [01] x 1 [02] x 1 [03] x 1 [04] x 1 [05] x 4 [06] x 1 [07] x 1 [08] x 1 [09] x 4 [10] x 4 [11] x 1 [12] x 4 (6x70mm) [13] x 4 (6.3x17x2mm) [14] x 8 (4x12x1mm) [15] x 4

More information

WC2 & WC3 Installation & Maintenance Instructions

WC2 & WC3 Installation & Maintenance Instructions WC2 & WC3 Installation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information WC3 shown WC2 WC3 IMPORTANT

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System User / Homeowner Guide

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System User / Homeowner Guide Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System User / Homeowner Guide Commissioning and Inspection Record: Located on page 5 of this guide, should have been completed

More information

SLIM-LINE RC FAN CONVECTOR.

SLIM-LINE RC FAN CONVECTOR. SLIM-LINE RC FAN CONVECTOR. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL Product Serial Number: Please leave this manual with the end user. Part Number: 1370064 heatingthroughinnovation. Contents

More information

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95 Your new Cooker Hood Using your new Cooker Hood is very simple. Nevertheless, to get the best results it is important that you read

More information

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use Internal/External Wall/Window Fan Range GX6 Installation and maintenance instructions Retain for future use A GLASS WINDOW B C D ( 6 see F ) 13 E1 E2 E3 G1 G2 G3 G4 H I GB Xpelair GX6, GXC6, GXC6T, GX6HT

More information

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide Commissioning and Inspection Record: Located on page 6 of this guide, should have been completed by the Commissioning Engineer.

More information

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions Green Line HRX Mechanical Ventilation with Heat Recovery appliance Installation and Operating Instructions Models: HRX-S, HRX-B, HRX-FP, HRX-BFP, HRX-FS, HRX-FB, HRX-FFP and HRX-FBFP These instructions

More information

BLOW DRY & GO HAIR KIT

BLOW DRY & GO HAIR KIT BLOW DRY & GO HAIR KIT LSGS11P Instruction Manual My BLow DRy and go HAiR KiT is perfect with everything you need to style your hair the way you want - wherever you are. This kit includes accessories for

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

Stainless Steel and Glass Angled Extractor

Stainless Steel and Glass Angled Extractor Stainless Steel and Glass Angled Extractor HJA2600 User & Installation Guide CONTENTS Environmental Note 3 Product information 4 4 Parts List 4 Method of Extraction 5 Installation 6 Hanging Your Extractor

More information

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning Sentinel Kinetic MVHR and Kinetic Plus MVHR Installation & Commissioning Stock Ref. N 438222 Kinetic B 443319 Kinetic BH 438342 Kinetic V 438342A Kinetic VS 443028 Kinetic Plus B 447938 Kinetic Plus BS

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

GUH90 90 cm Canopy Hood

GUH90 90 cm Canopy Hood User Manual for your GUH90 90 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of your

More information

Xpelair Simply Silent TM Contour Fan

Xpelair Simply Silent TM Contour Fan Xpelair Simply Silent TM Contour Fan Installation and Maintenance Instructions C4S (92960AW) / C4R (92961AW) C4TS (92962AW) / C4TR (92963AW) C4PS (92964AW) / C4PR (92965AW) C4HTS (92966AW) / C4HTR (92967AW)

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction

More information

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions HRX-aQ Range Mechanical Ventilation with Heat Recovery appliances Installation and Operating Instructions Models: AQH200-S, AQH200-B, AQH240-S, AQH240-B These instructions must be given to the householder

More information

100cm Chimney Hood GB IE

100cm Chimney Hood GB IE 100cm Chimney Hood GB IE [01] x 1 [02] x 2 [03] x 2 [04] x 2 [05] x 3 [06] x 1 [07] x 1 1 : 1 [09] x 8 (3.9 x 32mm) [08] x 8 [10] x 4 (4 x 12mm) 100cm Chimney Hood GB IE Cooker Hood 04 FR Hotte Aspirante

More information

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning Sentinel Kinetic MVHR and Kinetic Plus MVHR Installation & Commissioning Stock Ref. N 438222 Kinetic B 438222A Kinetic BS 443319 Kinetic BH 443319A Kinetic S BH 438342 Kinetic V 438342A Kinetic VS 443028

More information

EH0533 Indoor Climate Control

EH0533 Indoor Climate Control EH0533 Indoor Climate Control 2.8 kw of cooling, 2.9 kw of heating Air Conditioning Efficient heating (air-source heat-pump) Cooling Remote control Suitable for low-wall installation No external unit required

More information

MeacoCool MC Series Portable Air Conditioner

MeacoCool MC Series Portable Air Conditioner MeacoCool MC Series Portable Air Conditioner Thank you for choosing Meaco, we really do appreciate it INSTRUCTION MANUAL [EN] MC8000 MC8000CH MC9000 MC9000CH MC10000 MC10000CH SAFETY INFORMATION ATTENTION

More information

Stainless Steel Chimney Extractor

Stainless Steel Chimney Extractor Stainless Steel Chimney Extractor HJA2450-2 User & Installation Guide LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you

More information

MODEL: BV400 Part No:

MODEL: BV400 Part No: MODEL: BV400 Part No: 90000312 Mechanical Ventilation with Heat Recovery Installation and Commissioning Manual PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT INDEX 1. Introduction... 3 2. General Instructions...

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK PANEL HEATER OPERATING INSTRUCTIONS For Models: TWFP10000, TWFP10000-2PK This page is intentionally left blank General Care and Safety Guide Thank you for choosing a Living & Co Panel Heater. This Living

More information

HINTS AND TIPS Cleaning and maintenance HELPLINE

HINTS AND TIPS Cleaning and maintenance HELPLINE 43840 Rev1 23/10/08 16:17 Page 1 Descaling IMPORTANT: As this appliance is fitted with a concealed element, it must be descaled regularly. The frequency of descaling depends on usage and the hardness of

More information

Stainless Steel Chimney Extractor

Stainless Steel Chimney Extractor Stainless Steel Chimney Extractor User & Installation Guide LAM2404 LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you excellent

More information

GUH52SD 52 cm GUH75 75 cm Canopy Hood

GUH52SD 52 cm GUH75 75 cm Canopy Hood User Manual for your GUH52SD 52 cm GUH75 75 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most

More information

Warnings, Safety Information and Guidance

Warnings, Safety Information and Guidance EN SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems Warnings,

More information

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance MRXBOX95-WM2H Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0

More information

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved EnviroVent has been continually refining Filterless extract technology since it invented it 10 years ago, which has reduced social housing landlord s extractor fan maintenance costs by tens of millions

More information

Lucci Designer Hi Flow Exhaust Fan

Lucci Designer Hi Flow Exhaust Fan USE AND CARE INSTRUCTION INSTALLATION INSTRUCTION Lucci Designer Hi Flow Exhaust Fan SKU# 200265&200267 MXSQ8PW(200mm) SKU# 200266&200268 MXSQ10PW(250mm) Dear Customers, Thank you for selecting a LUCCI

More information

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions Green Line HRX Mechanical Ventilation with Heat Recovery appliance Installation and Operating Instructions Models: HRX-S, HRX-B, HRX-FP, HRX-BFP, HRX-FS, HRX-FB, HRX-FFP and HRX-FBFP These instructions

More information

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all

More information

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Integra Integra Plus EC MVHR Installation & Commissioning Stock Ref. N 437666EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Copyright 2009 Vent-Axia Limited. All rights reserved.

More information

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED I tho Advance Heat recovery ventilation unit User manual 226-0048/0111/ED 210.0998 A6_226-0048 Ventilator Advance ENGELS.indd 1 04-01-11 14:32 2 Contents 1. Introduction 4 1.1 Configuration 4 1.2 Itho

More information

100 FLUEBOOST

100 FLUEBOOST 100 FLUEBOOST f l u e b o o s t 1 0 0 The flueboost is a box shaped centrifugal fan unit with in line spigots for the flue connection, a pressure switch to ensure safe operation, all within a compact package.

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

1.8l Rice Cooker. Instruction Manual

1.8l Rice Cooker. Instruction Manual 1.8l Rice Cooker Instruction Manual Please read all instructions carefully and retain for future reference. Getting Started Remove the appliance from the box. Remove any packaging from the appliance. Place

More information