Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Size: px
Start display at page:

Download "Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:"

Transcription

1 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial applications. CERTIFICATION: All models are listed with UL, (U.S. and Canada), ARI, and CEC. ELECTRICAL RANGE: Units offered in single phase 208/230v are , three phase 208/230v in 036, 048 and 060, and three phase 460v in 060. FAN MOTOR: The totally enclosed fan motor provides greater reliability under adverse conditions and dependable performance for many years. The permanent split capacitor type motor was designed for optimum efficiency. The motor was then qualified under extreme conditions to help ensure a long, reliable life. CABINET: A weather protective cabinet of prepainted steel is protected underneath by a galvanized coating and treated with a layer of zinc phosphate for a finish that will last for many years. All screws on cabinet exterior are coated for a long -lasting, rust -resistant, quality appearance. UNIT DESIGN: The copper tube, enhanced sine wave, aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. The base pan is designed for easy removal of water, dirt, and leaves. COMPRESSOR: Each compressor is protected with internal temperature - and current -sensitive overloads. An internal pressure relief valve provides high pressure protection to the refrigerant system. For improved serviceability, all models are equipped with a compressor terminal plug. SERVICE VALVES: Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. SERVICEABILITY: One access panel provides access to electrical controls. Removal of top gives access to fan motor, compressor, and condenser coil. WARRANTY: Single Phase - Limited 5 -year compressor / 5 -year parts Three Phase - Limited 5 -year compressor / 1 -year parts

2 PRODUCT NUMBER NOMENCLATURE N R 018 A A AA 000 Electric Air Conditioner Series Variations Electrical Supply N / P / E Variations Variations 00G --- Dense Grille Refrigerant R --- R Nominal Capacity /2 Ton Tons /2 Tons Tons /2 Tons Ton Ton ISO 9001:2000 REGISTERED 2

3 SPECIFICATIONS UNIT SIZE SERIES A,E/ C A,E/ C A/B,E/ C A,E/C/ D A,E/C A,E/C A,E/C ELECTRICAL Unit VoltsHertzPhase 208/ / / / / / / / Operating Voltage Range* CompressorRated Load Amps / / / / /8.4 Locked Rotor Amps / / / / /55.0 Condenser Fan Motor Full Load Amps Min Unit Ampacity for Wire Sizing / / / / /11.2 Min Wire Size (60 /75 Copper) AWG** 14/14 14/14 12/12 12/12 14/14 10/ /12 8/8 12/12 14/14 Max Wire Length (60 /75 ) (Ft) 72/68 53/50 66/63 66/63 56/54 77/73 115/109 / 100/95 74/70 / 57/54 94/90 60/57 / 55/52 79/75 / 66/62 Max Branch Circuit Fuse Size / /35 15 COMPRESSOR AND REFRIGERANT CompressorManufacturer Copeland Type Scroll Temperature and Current Protection Internal Line Break Refrigerant R / 6.50 R / 7.00 R /5.60/ 7.50 R /8.00/ 7.20 R /11.95 R /12.83 R /17.37 TypeandAmountLb(kg)@15ft (1.98) / (2.95) (2.44) / (3.188) (2.56)/(2.54)/(3.40) (2.84)/(3.63)/(3.27) (4.15)/(5.42) (5.24)/(5.82) (5.24)/(7.88) Refrigerant Tubes (In. OD) Vapor and Liquid (Up to 80 Ft) 5/8 and 3/8 3/4 and 3/8 7/8 and 3/ /8 and 3/8 CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 11.26/ / /16.74/ /22.20/ / / /24.66 Fan MotorHP, Type, and RPM 1/12 PSC and 1100, 1/15 PSC and /8 PSC and 825 1/8 PSC and 825 1/5 PSC and 825 1/4 PSC and 1100 VoltsHertzPhase 208/ Condenser Airflow (CFM) OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start AssistPTC Type KAACS0201PTC N/A KAACS0201PTC N/A KAACS0201PTC N/A N/A Start AssistCapacitor/Relay Type KSAHS1501AAA N/A KSAHS1501AAA N/A KSAHS1601AAA N/A N/A MotorMaster Control # KSALA0401AAA KSALA0501AAA Ball Bearing Fan Motor (RCD) N/A HC38GE231 HC38GE232 HC38GE462 Low --- Pressure Switch KAALP0101LPS High --- Pressure Switch KSAHI0101HPS Compressor Sound Hood KSASH1801COP KSASH0601COP KSASH2101COP Time --- Delay Relay KAATD0101TDR Low--- Ambient Pressure Switch Kit KSALA0201R22 Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Compressor Crankcase Heater KAACH1401AAA KAACH1201AAA KAACH1301AAA Liquid Line Solenoid Valve KAALS0101LLS (Hard Shutoff) KSATX0601HSO KSATX0701HSO KSATX1001HSO Standard Thermostat, Manual Changeover, Non---Programmable, F/ C, TSTATPPBAC Stage Heat, 1 ---Stage Cool Thermostat, Auto Changeover, 7---Day Programmable, F/ C, 1 ---Stage Heat, TSTATPPPAC Stage Cool Outdoor Sensor TSTATXXSEN01--- B Liquid Line Filter Drier KH43LZ034 Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 N/A --- Not applicable in this application. * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. { Time---delay fuse or circuit breaker. } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** If wire is applied at ambient greater than 30 C, consult Table of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic---sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article {{ Do not use hard shutoff with liquid solenoid valve. # Requires ball---bearing fan motor. NOTES: 1. Control circuit is 24v on all units and requires external power source. 2. All motors/compressors contain internal overload protection. 3. Copper wire must be used from service disconnect to unit. 3

4 DIMENSIONS (SERIES A) 4

5 DIMENSIONS (SERIES C, D) 5

6 DIMENSIONS (SERIES B,E) B,E 6

7 OPTIONAL EQUIPMENT USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW---AMBIENT APPLICATIONS (Below 55 F/12.8_C) REQUIRED FOR LONG ---LINE APPLICATIONS* (Over 80 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Control Yes No No Wind Baffle See Low---Ambient Instructions No No Support Feet Recommended No Recommended Liquid---Line Solenoid Valve No See Long---Line Application Guideline No Hard Shutoff Yes Yes Yes Ball Bearing Fan Motor Yes No No ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings, which permits speed reduction while maintaining bearing lubrication. Required on all units when MotorMasterr Low -Ambient Controller is installed. 2. Compressor Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Required in low ambient applications. Required in long line applications. Suggested in all commercial applications. 3. Compressor Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas -bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart. 4. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a hard boost to compressor motor at each start up. Required for single-phase scroll compressors in the following applications: Long line Low ambient Suggested for all compressors in areas with a history of low voltage problems. 5. Compressor Start Assist - PTC Type Solid -state electrical device which gives a soft boost to the single -phase compressor motor at each start up. Suggested when compressor power supply is marginal Suggested in reciprocating single-phase compressor applications with rapid pressure balance (RPB) expansion valve on indoor coil. 6. Cycle Protector Solid -state timing device which prevents compressor rapid recycling. Control provides an approximate 5 -minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 80 ft (24.38 m). High -rise applications. 7. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze -up conditions. Required when low ambient kit has been added. 8. High -Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 426 ± 10 psig and resets at 320 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. Suggested in installations exposed to very dirty outdoor air. Suggested in installations where condenser inlet air temperature exceeds 125_F (51.7_C). 9. Liquid -Line Solenoid Valve (LLS) This device serves two purposes. It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle refrigerant migration. Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration. A hard shutoff can be used instead of LLS in single flow air conditioner applications. See Long Line Application Guideline. 7

8 ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)(Cont.) 10. Low -Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low -ambient temperatures down to 0_F (-17.8_C) when properly installed. A Low -Ambient Pressure Switch or Motor Masterr - Low -Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 11. Low -Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze -up due to loss of indoor airflow. Provides additional protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. Where indoor coil is exposed to dirty air. All commercial installations. 12. MotorMasterr -Low -Ambient Controller A fan speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ± 10_F. A MotorMasterr -Low -Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 13. Outdoor Air Temperature Sensor Designed for use with Payne Thermostats listed in this publication. The device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Suggested for all Payne thermostats listed in this publication. 14. Thermostatic Expansion Valve () Single-Flow A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB valves are available. Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off or LLS required in air conditioner long line applications. Required for use on all zoning systems. 15. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 16. Winter Start Control An SPST delay relay which bypasses the Low -Pressure Switch for approximately 3 minutes to permit start-up for cooling operation under low load conditions. All air conditioners to which Low -Pressure Switch and Low -Ambient Controller have been added 8

9 SOUND POWER Standard Typical Octave Band Spectrum (db, without tone adjustment) Unit Size Rating (dba) A,C,E A,C,E A,B,C,E C A,D,E A,C,E A,C,E A,C,E Note: Tested in accordance with ARI standard (Not listed with ARI) METERING DEVICE UNIT SIZE -SERIES INDOOR REQUIRED SUB -COOLING F ( C) 018 -A,C,E 024 -A,C,E 030 -A,B,C,E 036 -A,C,D,E 042 -A,C,E 048 -A,C,E 060 -A,C,E * 10 (5.6) * must be ordered separately when indoor coil is not equipped with a. must be hard---shutoff type. RECOMMENDED TUBE DIAMETERS UNIT SIZE TUBE LENGTH ft (m)* LIQUID TUBE DIAMETER (In.) VAPOR TUBE DIAMETER (In.) 018 5/8 024, 030, 036 0to80 3/4 3/8 042, 048 (0 to 24.38) 7/ /8 * For tube set over 80 ft horizontal and/or 20 ft (6.10 m) vertical differential, consult Residential Split Long---Line Application Guidelines. 9

10 RATINGS AND PERFORMANCE UNIT SIZE --- SERIES A,E C A,E C A,B,E See notes on pg. 11 SEER INDOOR MODEL TOTAL CAPACITY BTUH FACTORY --- SUPPLIED ENHANCEMENT STANDARD RATING PAYNE GAS FURNACE OR ACCESSORY TDR EER *CAR**1814A** 17,000 CAR**2414A** 17,600 CAR**2417A** 17,600 CNRV*1814A** 17,000 CNRV*2414A** 17,600 CNRV*2417A** 17,600 CNRH*2417A** 17,600 CNRF*2418A** 17,600 CSRH*2412A** 17,600 PF1MNC018 17,000 TDR& PF1MNC024 17,500 TDR& FF1ENE018 17,000 TDR& FF1ENE024 17,600 TDR& PF1MNC019 17,000 TDR& PF1MNC025 17,600 TDR& *CAR**1814A** CAR**2414A** CAR**2417A** CNRV*1814A** CNRV*2414A** CNRV*2417A** CNRH*2417A** CNRF*2418A** CSRH*2412A** PF1MNC018 PF1MNC024 PF1MNC019 PF1MNC025 FF1ENE018 FF1ENE024 16,800 17,400 17,400 17,000 17,500 17,500 17,500 17,500 17,600 17,000 17,200 17,200 17,200 17,000 17,400 TDR& TDR& TDR& TDR& TDR& TDR& *CAR**2414A** 23,000 CAR**2417A** 23,000 CAR**3014A** 23,400 CAR**3017A** 23,400 CNRV*2414A** 23,000 CNRV*2417A** 23,000 CNRV*3014A** 23,400 CNRV*3017A** 23,400 CNRH*2417A** 23,000 CNRH*3017A** 23,400 CNRF*2418A** 23,000 CSRH*2412A** 23,000 CSRH*3012A** 23,400 PF1MNC024 23,000 TDR& PF1MNC030 23,200 TDR& FF1ENE024 23,000 TDR& FF1ENE030 23,200 TDR& PF1MNC025 23,000 TDR& PF1MNC031 23,200 TDR& *CAR**2414A** CAR**2417A** CAR**3014A** CAR**3017A** CNRV*2414A** CNRV*2417A** CNRV*3014A** CNRV*3017A** CNRH*2417A** CNRH*3017A** CNRF*2418A** CSRH*2412A** CSRH*3012A** PF1MNC024 PF1MNC030 PF1MNC025 PF1MNC031 FF1ENE024 FF1ENE030 23,000 23,000 23,000 23,000 22,800 22,800 22,800 23,000 22,800 23,000 22,800 23,000 23,000 22,800 23,000 23,000 23,200 22,800 22,800 TDR& TDR& TDR& TDR& TDR& TDR& *CAR**3014A** 28,000 CAR**3017A** 28,000 CAR**3614A** 28,400 CAR**3617A** 28,400 CAR**3621A** 28,400 CNRV*3014A** 28,000 CNRV*3017A** 28,000 CNRV*3617A** 28,200 CNRV*3621A** 28,200 CNRH*3017A** 28,000 CNRH*3617A** 28,200 10

11 RATINGS AND PERFORMANCE (CONT.) UNIT SIZE --- SERIES A,B,E C A,E C, D See notes on pg. 11 SEER INDOOR MODEL TOTAL CAPACITY BTUH FACTORY --- SUPPLIED ENHANCEMENT STANDARD RATING PAYNE GAS FURNACE OR ACCESSORY TDR EER CNRF*3618A** 28,200 CSRH*3012A** 28,000 CSRH*3612A** 28,600 PF1MNC030 28,000 TDR& PF1MNC036 28,200 TDR& FF1ENE030 28,000 TDR& FF1ENE036 28,400 TDR& PF1MNC031 28,000 TDR& PF1MNC037 28,400 TDR& *CAR**3014A** CAR**3017A** CAR**3614A** CAR**3617A** CAR**3621A** CNRV*3014A** CNRV*3017A** CNRV*3617A** CNRV*3621A** CNRH*3017A** CNRH*3617A** CNRF*3618A** CSRH*3012A** CSRH*3612A** PF1MNC030 PF1MNC036 PF1MNC031 PF1MNC037 FF1ENE030 FF1ENE036 28,000 28,000 28,400 28,400 28,400 28,000 28,000 28,200 28,200 28,000 28,200 28,200 28,000 28,600 28,000 28,200 28,200 28,200 28,000 28,400 TDR& TDR& TDR& TDR& TDR& TDR& *CAR**3617A** 34,000 CAR**3614A** 34,000 CAR**3621A** 34,000 CAR**4221A** 34,400 CAR**4224A** 34,400 CNRV*3617A** 34,000 CNRV*3621A** 34,000 CNRV*4221A** 34,400 CNRH*3617A** 33,800 CNRH*4221A** 34,400 CNRF*3618A** 34,000 CSRH*3612A** 34,000 CSRH*4212A** 34,400 PF1MNC036 34,000 TDR& PF1MNC042 34,400 TDR& PF1MNC043 35,000 TDR& FF1ENE036 34,000 TDR& PF1MNC037 34,400 TDR& *CAR**3617A** CAR**3614A** CAR**3621A** CAR**4221A** CAR**4224A** CNRV*3617A** CNRV*3621A** CNRV*4221A** CNRH*3617A** CNRH*4221A** CNRF*3618A** CSRH*4212A** PF1MNC036 PF1MNC042 PF1MNC037 PF1MNC043 FF1ENE036 34,000 34,000 34,000 34,400 34,400 34,000 34,000 34,400 33,800 34,400 34,000 34,400 34,000 34,400 34,400 35,000 34,000 TDR& TDR& TDR& TDR& TDR&

12 RATINGS AND PERFORMANCE (CONT.) UNIT SIZE --- SERIES A,E C A,E C See notes on pg. 11 SEER INDOOR MODEL TOTAL CAPACITY BTUH FACTORY --- SUPPLIED ENHANCEMENT STANDARD RATING PAYNE GAS FURNACE OR ACCESSORY TDR EER *CAR**4221A** 40,000 CAR**4224A** 40,000 CAR**4817A** 41,000 CAR**4821A** 41,000 CAR**4824A** 41,000 CNRV*4221A** 40,000 CNRV*4821A** 41,000 CNRV*4824A** 41,000 CNRH*4221A** 40,000 CNRH*4821A** 41,000 CNRF*4818A** 41,000 CSRH*4212A** 40,000 CSRH*4812A** 41,000 PF1MNC042 40,000 TDR& PF1MNC048 40,000 TDR& PF1MNC043 41,000 TDR& PF1MNC049 41,500 TDR& *CAR**4221A** CAR**4224A** CAR**4817A** CAR**4821A** CAR**4824A** CNRV*4221A** CNRV*4821A** CNRV*4824A** CNRH*4221A** CNRH*4821A** CNRF*4818A** CSRH*4212A** CSRH*4812A** PF1MNC042 PF1MNC043 PF1MNC048 PF1MNC049 40,000 40,000 41,000 41,000 41,000 40,000 41,000 41,000 40,000 41,000 41,000 40,000 41,000 40,000 40,000 41,500 41,000 TDR& TDR& TDR& TDR& *CAR**4821A** 46,000 CAR**4817A** 46,000 CAR**4824A** 46,000 CAR**6021A** 47,000 CAR**6024A** 47,000 CNRV*4821A** 46,000 CNRV*4824A** 46,000 CNRV*6024A** 47,000 CNRH*4821A** 46,000 CNRH*6024A** 47,000 CNRF*4818A** 45,000 CSRH*4812A** 46,000 CSRH*6012A** 47,000 PF1MNC048 46,000 TDR& PF1MNC060 47,000 TDR& PF1MNC049 47,500 TDR& PF1MNC061 48,000 TDR& *CAR**4821A** 46,000 CAR**4817A** 46,000 CAR**4824A** 46,000 CAR**6021A** 47,000 CAR**6024A** 47,000 CNRV*4821A** 46,000 CNRV*4824A** 46,000 CNRV*6024A** CNRH*4821A** 47,000 46,000 CNRH*6024A** 47,000 CNRF*4818A** 45,000 CSRH*4812A** 46,000 CSRH*6012A** 47,000 PF1MNC048 46,000 TDR& PF1MNC060 47,000 TDR& PF1MNC049 47,500 TDR& PF1MNC061 48,000 TDR&

13 RATINGS AND PERFORMANCE (CONT.) UNIT SIZE --- SERIES A,E C SEER INDOOR MODEL TOTAL CAPACITY BTUH FACTORY --- SUPPLIED ENHANCEMENT STANDARD RATING PAYNE GAS FURNACE OR ACCESSORY TDR EER *CAR**6024A** 57,000 CAR**6021A** 56,500 CNRV*6024A** 57,000 CNRH*6024A** 57,000 CSRH*6012A** 57,000 PF1MNC060 56,500 TDR& PF1MNC061 57,500 TDR& *CAR**6024A** 57,000 CAR**6021A** 56,500 CNRV*6024A** 57,000 CNRH*6024A** 57,000 CSRH*6012A** 57,000 PF1MNC060 56,500 TDR& PF1MNC061 57,500 TDR& * Tested Combination { In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Payne furnaces are equipped with TDR. } Requires hard shutoff ; based on computer simulation. EER --- Energy Efficiency Ratio SEER --- Seasonal Energy Efficiency Ratio TDR --- Time --- Delay Relay. --- Thermostatic Expansion Valve. NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Minimum outdoor operating ambient in cooling mode is 55_F (12.8_C), maximum 115_F (46.1_C). 13

14 DETAILED COOLING CAPACITIES* EVAPORATOR AIR CFM EWB _F (_C) See notes on pg. 18 CONDENSER ENTERING AIR TEMPERATURES F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) Total Sens Total Sens Total Sens Total Sens Total Sens NR018--A, C, E Outdoor Section With CAR**1814** Indoor Section 72 (22.2) (13.9) (22.2) (13.9) (22.2) (13.9) Multipliers for Determining the Performance With Other Indoor Sections NR018--C NR018--A,E Indoor Unit Cooling *CAR**1814A** CAR**2414A** CAR**2417A** CNRV*1814A** CNRV*2414A** CNRV*2417A** CNRH*2417A** CNRF*2418A** CSRH*2412A** PF1MNC PF1MNC FF1ENE FF1ENE PF1MNC PF1MNC Indoor Unit Cooling CAR**1814A** CAR**2414A** CAR**2417A** CNRF*2418A** CNRH*2417A** CNRV*1814A** CNRV*2414A** CNRV*2417A** CSRH*2412A** FF1ENE FF1ENE PF1MNC PF1MNC PF1MNC PF1MNC

15 DETAILED COOLING CAPACITIES* EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES F ( C) (29.4) 95 (35) 105 (40.6) 115 (46.1) Total Sens Total Sens Total Sens Total Sens Total Sens NR024--A,C, E Outdoor Section With CAR**2414** Indoor Section 72 (22.2) (13.9) (22.2) (13.9) (22.2) (13.9) Indoor Unit See notes on pg. 18 NR024--A,E Cooling *CAR**2414A** CAR**2417A** CAR**3014A** CAR**3017A** CNRV*2414A** CNRV*2417A** CNRV*3014A** CNRV*3017A** CNRH*2417A** CNRH*3017A** CNRF*2418A** CSRH*2412A** CSRH*3012A** PF1MNC PF1MNC FF1ENE FF1ENE PF1MNC PF1MNC Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit NR024--C Cooling CAR**2414A** CAR**2417A** CAR**3014A** CAR**3017A** CNRF*2418A** CNRH*2417A** CNRH*3017A** CNRV*2414A** CNRV*2417A** CNRV*3014A** CNRV*3017A** CSRH*2412A** CSRH*3012A** FF1ENE FF1ENE PF1MNC PF1MNC PF1MNC PF1MNC

16 DETAILED COOLING CAPACITIES* EVAPORATOR AIR CFM EWB See notes on pg. 18 Indoor Unit Capacity MBtuh CONDENSER ENTERING AIR TEMPERATURES F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Sens Total Sens Total Sens Total Sens Total Sens NR030--A,C,E Outdoor Section With CAR**3014** Indoor Section 72 (22.2) (13.9) (22.2) (13.9) (22.2) (13.9) Multipliers for Determining the Performance With Other Indoor Sections NR030 -A,E Cooling *CAR**3014A** CAR**3017A** CAR**3614A** CAR**3617A** CAR**3621A** CNRV*3014A** CNRV*3017A** CNRV*3617A** CNRV*3621A** CNRH*3017A** CNRH*3617A** CNRF*3618A** CSRH*3012A** CSRH*3612A** PF1MNC PF1MNC FF1ENE FF1ENE PF1MNC PF1MNC Indoor Unit NR030 -C Cooling CAR**3014A** CAR**3017A** CAR**3614A** CAR**3617A** CAR**3621A** CNRF*3618A** CNRH*3017A** CNRH*3617A** CNRV*3014A** CNRV*3017A** CNRV*3617A** CNRV*3621A** CSRH*3012A** CSRH*3612A** FF1ENE FF1ENE PF1MNC PF1MNC PF1MNC PF1MNC Total 16

17 DETAILED COOLING CAPACITIES* EVAPORATOR AIR CFM EWB CONDENSER ENTERING AIR TEMPERATURES F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) Total Sens Total Capacity MBtuh Total Sens Total Sens Total Sens Total Sens NR036 -A, C, D, E Outdoor Section With CAR**3617** Indoor Section 72 (22.2) (13.9) (22.2) (13.9) (22.2) (13.9) Multipliers for Determining the Performance With Other Indoor Sections INDOOR UNIT ANR036--A,E COOLING *CAR**2414A** CAR**2417A** CAR**3014A** CAR**3017A** CNRV*2414A** CNRV*2417A** CNRV*3014A** CNRV*3017A** CNRH*2417A** CNRH*3017A** CNRF*2418A** CSRH*2412A** CSRH*3012A** PF1MNC PF1MNC FF1ENE FF1ENE PF1MNC PF1MNC See notes on pg. 18 Indoor Unit NR036--C, D Cooling CAR**3614A** CAR**3617A** CAR**3621A** CAR**4221A** CAR**4224A** CNRF*3618A** CNRH*3617A** CNRH*4221A** CNRV*3617A** CNRV*3621A** CNRV*4221A** CSRH*4212A** FF1ENE PF1MNC PF1MNC PF1MNC PF1MNC

18 DETAILED COOLING CAPACITIES* EVAPORATOR AIR CFM EWB 1225 CONDENSER ENTERING AIR TEMPERATURES F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) Total Sens Total Sens Total Sens Total Sens Total Sens NR042-- A, C, E Outdoor Section With CAR**4221** Indoor Section 72 (22.2) (13.9) (22.2) (13.9) (22.2) (13.9) Multipliers for Determining the Performance With Other Indoor Sections See notes on pg. 18 INDOOR UNIT ANR042---A,E COOLING *CAR**4221A** CAR**4224A** CAR**4817A** CAR**4821A** CAR**4824A** CNRV*4221A** CNRV*4821A** CNRV*4824A** CNRH*4221A** CNRH*4821A** CNRF*4818A** CSRH*4212A** CSRH*4812A** PF1MNC PF1MNC PF1MNC PF1MNC Indoor Unit NR042--C Cooling CAR**4221A** CAR**4224A** CAR**4817A** CAR**4821A** CAR**4824A** CNRF*4818A** CNRH*4221A** CNRH*4821A** CNRV*4221A** CNRV*4821A** CNRV*4824A** CSRH*4212A** CSRH*4812A** PF1MNC PF1MNC PF1MNC PF1MNC

19 DETAILED COOLING CAPACITIES* EVAPORATOR AIR CFM EWB 1400 CONDENSER ENTERING AIR TEMPERATURES F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) Total Sens Total Sens Total Sens Total Sens Total Sens NR048--A, C, E Outdoor Section With CAR**4821** Indoor Section 72 (22.2) (13.9) (22.2) (13.9) (22.2) (13.9) Multipliers for Determining the Performance With Other Indoor Sections NR048--C ANR048---A,E INDOOR UNIT COOLING *CAR**4821A** CAR**4817A** CAR**4824A** CAR**6021A** CAR**6024A** CNRV*4821A** CNRV*4824A** CNRV*6024A** CNRH*4821A** CNRH*6024A** CNRF*4818A** CSRH*4812A** CSRH*6012A** PF1MNC PF1MNC PF1MNC PF1MNC Indoor Unit Cooling CAR**4817A** CAR**4821A** CAR**4824A** CAR**6021A** CAR**6024A** CNRF*4818A** CNRH*4821A** CNRH*6024A** CNRV*4821A** CNRV*4824A** CNRV*6024A** CSRH*4812A** CSRH*6012A** PF1MNC PF1MNC PF1MNC PF1MNC See notes on pg

20 DETAILED COOLING CAPACITIES* EVAPORATOR AIR CFM EWB (22.2) 57 (13.9) 72 (22.2) 57 (13.9) 72 (22.2) 57 (13.9) Capacity MBtuh CONDENSER ENTERING AIR TEMPERATURES F ( C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Sens Total Sens Total Sens Total Sens Total Sens NR060--A, B, C, E Outdoor Section With CAR**6024** Indoor Section Multipliers for Determining the Performance With Other Indoor Sections Total ANR060--A,B,E INDOOR UNIT COOLING *CAR**6024A** CAR**6021A** CNRV*6024A** CNRH*6024A** CSRH*6012A** PF1MNC PF1MNC Indoor Unit NR060--C Cooling CAR**6021A** CAR**6024A** CNRH*6024A** CNRV*6024A** CSRH*6012A** PF1MNC PF1MNC * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation, per ARI Standard 210/ , and connected by 25 ft of tubing. If other than 25 ft of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. { Total and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). When the required data falls between the published data, interpolation may be performed. ** Unit kw is total of indoor and outdoor unit kilowatts. 20

21 SYSTEM DESIGN 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than in. wc. 2. Minimum outdoor operating air temperature without low -ambient operation accessory is 55_F (12.8_C). 3. Maximum outdoor operating air temperature is 115_F (46.1_C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 80 ft (24.38 m), indoor coil below = 200 ft (60.96). 6. For interconnecting refrigerant tube lengths greater than 80 ft (24.38 m) horizontal or 20 ft (6.10 m) vertical differential, consult Residential Split Long -Line Application Guideline available from equipment distributor. 7. Crankcase heater required when interconnecting refrigerant tube length exceeds 80 ft (24.38 m). 8. If any refrigerant tubing is buried, provide a minimum 6 in (152.4 mm). vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in (914.4 mm). may be buried without further consideration. 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 21

22 E 2007 Payne Heating & Cooling s 7310 W. Morris St. Indianapolis, IN Printed in U.S.A. Edition Date: 06/07 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. SS Replaces: SS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES: (60 Hz) 13 SEER Air Conditioner Sizes 018 --- 060 Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant, AVAILABLE SIZES: CERTIFICATION: Nominal sizes available from 018 through 060 to meet the needs of residential and light commercial applications. All models are listed with UL, c-ul, ARI, CEC, and CSA-

More information

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data PA13NA PA13PA FEATURES AND BENEFITS PA13NA PA13PA 13 SEER Split---System Air Conditioner With R---410A Refrigerant Single & Three Phase 1 --- 1/2 To 5 Tons Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from

More information

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: ELECTRICAL RANGE: FAN MOTOR: CABINET: UNIT

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable cooling performance.

More information

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling PAYNE Heating & ELECTRIC CONDITIONER 710A (60 Hz) Sizes 018 thru 060 Model 710A Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable summer cooling performance.

More information

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS Product Data 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 The 38CKS Air Conditioner is designed for superior performance durability in harsh environments. The product achieves

More information

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1 12 SEER ELECTRIC AIR CONDITIONER 563G (60 Hz) Sizes 018 thru 060 Model 563G Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5 12 SEER AIR CONDITIONER 563C Sizes 018 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are

More information

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11 12 SEER ELECTRIC AIR CONDITIONER 563C (60 Hz) Sizes 024 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: With SEER of at least 10.0 and HSPF of 6.8,

More information

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC 50 Hz Air Conditioner Sizes 018 thru 060 Model 38CKC 50 Hertz energyefficient air conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S BH13NA 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH13 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES AVAILABLE SIZES: 18,000 to 60,000 Btu CERTIFICATION: U.L., c-ul, ARI and CEC Listed ELECTRICAL RANGE: 208 230v, 60 Hertz, 1 Phase COMPRESSOR PROTECTION: Each compressor is protected with internal temperature-

More information

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton PRODUCT NUMBER NOMENCLATURE 14 SEER Air Conditioner with Refrigerant PA14 N C 018 00G B A Series Variations Electrical Supply N 208/230 60 1 00G Variations C Nominal Capacity 018 1 1/2Ton 024 2Tons 030

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS. (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1 --- 1/2 to 5 Nominal Tons) Product Data The Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter

More information

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38BRC (60 Hz) Air Conditioner Sizes 024 thru 060 Model 38BRC Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into

More information

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8 ELECTRIC AIR CONDITIONER 597C (60 Hz) Sizes 018 thru 060 The Reliant AeroQuiet System (AQS) consists of 3 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

A 14 SEER Heat Pump with R---410A Refrigerant Series

A 14 SEER Heat Pump with R---410A Refrigerant Series MODEL NUMBER NOMENCLATURE PH14 N B 018 00G B A 14 SEER Heat Pump with R---410A Refrigerant Series Electrical Supply N=208/230---1 P=208/230---3 E=460/3 B R---410A Nominal Capacity 018 1 1/2Tons 024 2Tons

More information

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38YCC 50 Hz Heat Pump Sizes 024 thru 060 The 38YCC 50 Hertz Outdoor s of Split-System Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Product Data Bryant Heat Pumps with Puronr refrigerant provide a collection of features unmatched by any other family

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Baset13 Air Conditioner with Puronr Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other

More information

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24AHA4 Performance Series Air Conditioner with Refrigerant 1-1/2 to 5 Nominal Tons Product Data Carrier air conditioners with refrigerant provide a collection of features unmatched by any other family

More information

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38BYG (60 Hz) 12 SEER Heat Pump s 018 thru 060 The 38BYG Outdoor s of Split- Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS Product Data Bryant Air Conditioners with refrigerant provide a collection of features unmatched by any other

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

Product Data. Efficiency. S S Reliability

Product Data. Efficiency. S S Reliability 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH14 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24ABC6 Comfortt16 Air Conditioner with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES 10 SEER HEAT PUMP UNIT 661C Sizes 018 thru 060 The 661C Outdoor Section of Split- Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER up to 11.5

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant Sizes 018 thru 060 Model 38ETG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling

More information

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4 DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) 550A (60 Hz) Sizes 024 thru 060 Bryant s Quantum Plus 550A with Puron provides a completely unique collection of features which cannot be matched by any

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 114CNC Legacyt Line Air Conditioner for Coastal Applications with r Refrigerant 1--1/2 To 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14.0 SEER / 11.0 13.5 EER S Microtube

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCD

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons 116B Legacyt Line 16 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38EZG (60 Hz) Air Conditioner with Puron Sizes 018 thru 060 Copyright 2003 Carrier Corporation Model 38EZG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet,

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched by

More information

697C (60 HZ) Sizes 018 thru 060

697C (60 HZ) Sizes 018 thru 060 SPLIT-SYSTEM HEAT PUMP UNITS 697C (60 HZ) s 018 thru 060 The AeroQuiet System (AQS) consists of 4 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. CA13NA 018 060 Base Series Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s non -ozone depleting refrigerant. INDUSTRY LEADING FEATURES / BENEFITS Efficiency

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4**C Comfort 14 Heat Pump for Coastal Applications with r Refrigerant 1---1/5 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5 -- 11.7 EER / 8.2 HSPF

More information

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS. Performancet 16 2 --- Stage Heat Pump with Puronr Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with Puron r refrigerant provide a collection of features

More information

Product Data. Efficiency

Product Data. Efficiency BH14NB SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5-11.7 EER / 8.2 HSPF S Microtube Technologyt refrigeration

More information

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Product Data 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Carrier s WeatherMaker 38TXA with Puron provides a completely unique collection of features which cannot be matched by

More information

Advance Product Data

Advance Product Data Comfort 14 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Advance Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched

More information

Installation Instructions

Installation Instructions MODEL LEGACYT ERIE R-22 AIR CONDITIONER IZE 018 TO 060 1-1/2 TO 5 NOMINAL TON Installation Instructions TM INDUTRY LEADING FEATURE / BENEFIT Efficiency ound Comfort Reliability Durability 13 EER / 11.0

More information

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1 QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT 650A (60 Hz) Sizes 024 thru 060 The Quantum Plus line of split-system outdoor units has been expanded to include the Model 650A 13 SEER heat pump (with

More information

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier Heat Pumps with Puronr refrigerant provide a collection of features

More information

R 410A Ducted Horizontal Air Conditioner

R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS, 208/230

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4 Comfort 14 Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant Product Data 38YXA (60Hz) Deluxe 13 SEER Split- Heat Pump with Puron (R-410A) Refrigerant Sizes 024 thru 060 INTRODUCING THE WEATHERMAKER 38YXA HEAT PUMP FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

More information

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES Product Data 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant Sizes 018 thru 060 Carrier s technological leadership has risen to a new level with the development of the 38EYG Heat Pump, the outdoor

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. 018---060 Base eries Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability 25HPB6 Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Tons Product Data the environmentally sound refrigerant Carrier heat pumps with Puronr refrigerant provide a collection of features

More information

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t Infinityr 15 Heat Pump with Puronr Refrigerant 2to4NominalTons(Sizes24---48) Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

INDUSTRY LEADING FEATURES 2 5 / BENEFITS Infinityr 19 2 --- Stage Heat Pump with Puronr Refrigerant 2to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Product Data 38EYA (60Hz) 12 SEER Split- Cube Heat Pump with Puron Refrigerant Sizes 018 thru 060 FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Carrier s technological leadership has risen to a

More information

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS,

More information

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation Product Data 38YCA (60 Hz) 38YCN Heat Pump HEATING & COOLING 38YCA s 018 thru 060 38YCN s 024 thru 048 The 38YCA and 38YCN Outdoor s of Split- Heat Pumps are designed for quiet, reliable heating during

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound 24VNA0 Infinityr Variable Speed Air Conditioner with Greenspeedr Intelligence 2to5NominalTons Product Data Carrier s 24VNA0 with Greenspeed R Intelligence is a variable speed cooling product providing

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES Product Data Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant Sizes 024 thru 060 Carrier s Performance 14 Air Conditioners with Puron refrigerant provide a collection of features unmatched

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Advance Product Data

Advance Product Data EVOLUTION R V VARIABLE SPEED AIR CONDITIONER WITH PURONr REFRIGERANT 2, 3, AND 4-TON (5-TON COMING Q4 2014) Advance Product Data The Evolution V air conditioner offers high -efficiency variable speed performance

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3 DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT 652A Sizes 018 thru 060 TM The 652A split-system outdoor unit is a 12 SEER heat pump (with efficiencies up to 14.0 SEER). Homeowners will appreciate this

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design

More information

Advance Product Data

Advance Product Data Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Legacy-RNC eries Air Conditioner with Puronr Product Data the environmentally sound refrigerant A05233 Bryant s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any

More information