UPFLOW NATURAL GAS FURNACES - 90%
|
|
- Marjorie Manning
- 5 years ago
- Views:
Transcription
1 Y W R G C UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: Rev. C (1201) Rev. D (302) 1 of COOL HEAT CIR Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM DESCRIPTION P3URA10N03701E P3URB10N05501E P3URB12N07501E P3URC16N07501E G9T04010UPA13C G9T06010UPB13C G9T08012UPB13C G9T08016UPC13C FG9A04010UP11C FG9B06010UP11C FG9B08012UP11C FG9C08016UP11C (2 BURNER) (3 BURNER) (4 BURNER) (4 BURNER) MOTOR 1 1 MOTOR,DIRECT DRIVE BLOWER MOTOR,VENTOR ASS Y ELECTRICAL 1 3 CAPACITOR (7.5MFD/370V) CAPACITOR (10 MFD/370V) CAPACITOR, VENTOR (4MFD/370V) CONTROL, HIGH LIMIT ,3 6 CONTROL,FLAME ROLL OUT CONTROL,FURNACE * 7A FUSE ,3 8 IGNITER ,3 9 SENSOR, FLAME SWITCH, AIR PRESSURE [LP] SWITCH, DOOR TRANSFORMER ,3 13 VALVE, GAS AIR MOVING 1 14 CUTOFF,BLOWER HOUSING, BLOWER WHEEL, BLOWER Unitary Products Group
2 Y W R G C Rev. D (302) 2 of COOL HEAT CIR Figure 2: UPFLOW NATURAL GAS FURNACES (90%) P3URA10N03701E P3URB10N05501E P3URB12N07501E P3URC16N07501E FIG ITEM DESCRIPTION G9T04010UPA13C G9T06010UPB13C G9T08012UPB13C G9T08016UPC13C FG9A04010UP11C FG9B06010UP11C FG9B08012UP11C FG9C08016UP11C (2 BURNER) (3 BURNER) (4 BURNER) (4 BURNER) FABRICATED PARTS 2 17 BAFFLE, AIR (LH Recoup.Coil) BAFFLE, AIR (RH Recoup.Coil) BURNER, MAIN GAS COIL, SECONDARY HEAT EXCHANGER DECK, BLOWER (Rear) DECK, FRONT HEAT EXCHANGER ASS Y (Primary) ,3 24 MANIFOLD, GAS PAN, BASE PAN, CONDENSATE ,3 27 PANEL, BURNER BOX (Bottom) PANEL, BURNER BOX (Front) ,3 29 WRAPPER, BURNER BOX CHANNEL, TOE PLATE COVER, HEAT EXCHANGER PANEL, FRONT (Blower) < 2 33 PANEL, FRONT (Burner) < 2 34 PANEL, TOP SUPPORT, BURNER WRAPPER, CABINET P3U WRAPPER, CABINET G9T,FG < 2 37 PANEL, VESTIBULE (Lower) PLUG, WINDOW, CLEAR
3 3 of Rev. D (302) ,42 24 OFF ON ,61 27 Figure 3: GAS CONTROLS (90%) P3URA10N03701E P3URB10N05501E P3URB12N07501E P3URC16N07501E FIG ITEM DESCRIPTION G9T04010UPA13C G9T06010UPB13C G9T08012UPB13C G9T08016UPC13C FG9A04010UP11C FG9B06010UP11C FG9B08012UP11C FG9C08016UP11C (2 BURNER) (3 BURNER) (4 BURNER) (4 BURNER) MISCELLANEOUS * 39 CLIP, FILTER RETAINER(2Req d)p3u,g9t COLLAR, AIR INTAKE (Burner Box) * 41 FILTER, AIR (2 Req d.) P3U, G9T FILTER SIZE (1 X 16 X 26) (1 X 16 X 26) (1 X 16 X 26) (1 X 20 X 26) 3 42 GASKET, AIR INTAKE GASKET, COMBUSTION BLOWER GASKET, CONDENSATE PAN GASKET, BURN BOX TO VEST PANEL GROMMET, MANIFOLD SEAL PLUG, WINDOW,CLEAR HANDLE, DOOR ISOLATOR, TUBE (3 Req d.) ISOLATOR, WASHER (3 Req d.) ISOLATOR,SLEEVE (3 Req d.) MOUNT, MOTOR ORIFICE, BURNER (Natural #45) * 55 RETAINER, FILTER P3U, G9T TRAP, CONDENSATE * 57 WIRING DIAGRAM TUBE, DRAIN RAIN GUTTER TUBE, CONDENSATE DRAIN TUBE, DRAIN CONDENSATE TRAP BRACKET, IGNITOR TUBE, DRAIN CONDENSATE PAN PIPE EXHAUST VENT Unitary Products Group
4 Y W R G C Rev. D (302) 4 of CIR COOL HEAT Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM MOTOR DESCRIPTION P3URC14N09501E P3URC20N09501E P3URD20N11201E P3URD20N13001E G9T10014UPC13C G9T10020UPC13C G9T12020UPD13C G9T14020UPD13C FG9C10014UP11C FG9C10020UP11C FG9D12020UP11C FG9D14020UP11C (5 BURNER) (5 BURNER) (6 BURNER) (7 BURNER) 1 1 MOTOR,DIRECT DRIVE BLOWER MOTOR,VENTOR ASS Y ELECTRICAL 1 3 CAPACITOR (10MFD/370V) CAPACITOR (15MFD/370V) CAPACITOR, VENTOR (4MFD/370V) CONTROL, HIGH LIMIT ,3 6 CONTROL,FLAME ROLL OUT (2 ea,) CONTROL,FURNACE * 7A FUSE ,3 8 IGNITER ,3 9 SENSOR, FLAME SWITCH, AIR PRESSURE [1LP] SWITCH, DOOR TRANSFORMER ,3 13 VALVE, GAS AIR MOVING 1 14 CUTOFF, BLOWER HOUSING, BLOWER WHEEL, BLOWER New replacemnt parts shown in bold face type at the first printing of parts list code dated 3/02. Major components and suggested stockings items are shown with shaded item number.
5 Y W R G C 5 of Rev. D (302) COOL HEAT CIR Figure 2: UPFLOW NATURAL GAS FURNACES (90%) P3URC14N09501E P3URC20N09501E P3URD20N11201E P3URD20N13001E FIG ITEM DESCRIPTION G9T10014UPC13C G9T10020UPC13C G9T12020UPD13C G9T14020UPD13C FG9C10014UP11C FG9C10020UP11C FG9D12020UP11C FG9D14020UP11C (5 BURNER) (5 BURNER) (6 BURNER) (7 BURNER) FABRICATED PARTS 2 17 BAFFLE, AIR (LH Recoup.Coil) BAFFLE, AIR (RH Rcoup. Coil) BURNER, MAIN GAS COIL, SECONDARY HEAT EXCHANGER DECK, BLOWER (Rear) DECK, FRONT HEAT EXCHANGER ASS Y(Pri mary) 2,3 24 MANIFOLD, GAS PAN, BASE PAN, CONDENSATE ,3 27 PANEL, BURNER BOX (Bottom) PANEL, BURNER BOX (Front) ,3 29 WRAPPER, BURNER BOX CHANNEL, TOE PLATE COVER, HEAT EXCHANGER PANEL, FRONT (Blower) < 2 33 PANEL, FRONT (Burner) < 2 34 PANEL, TOP SUPPORT, BURNER WRAPPER, CABINET P3U WRAPPER, CABINET G9T,FG PANEL, VESTIBULE (Lower) PLUG, WINDOW,CLEAR Unitary Products Group
6 Rev. D (302) 6 of ,42 24 OFF ON ,61 Figure 3: GAS CONTROLS (90%) FIG ITEM DESCRIPTION 27 P3URC14N09501E P3URC20N09501E P3URD20N11201E P3URD20N13001E G9T10014UPC13C G9T10020UPC13C G9T12020UPD13C G9T14020UPD13C FG9C10014UP11C FG9C10020UP11C FG9D12020UP1C FG9D14020UP11C (5 BURNER) (5 BURNER) (6 BURNER) (7 BURNER) MISCELLANEOUS * 39 CLIP, FLITER RETAINER (2Req d)p3u,g9t COLLAR, AIR INTAKE (Burner Box) * 41 FILTER, AIR (2 Req.d.) P3U, G9T FILTER SIZE (1 X 20 X 26) (1 X 20 X 26) (1 X 24 X 26) (1 X 24 X 26) 3 42 GASKET, AIR INTAKE GASKET, COMBUSTION BLOWER GASKET, CONDENSATE PAN GASKET, BURN BOX TO VEST PANEL GROMMET, MANIFOLD SEAL PLUG, WINDOW, CLEAR HANDLE, DOOR ISOLATOR, TUBE (3 Req d.) ISOLATOR, WASHER (3 Req d.) ISOLATOR,SLEEVE (3 Req d.) MOUNT, MOTOR ORIFICE, BURNER (Natural #45) * 55 RETAINER, FILTER P3U, G9T TRAP, CONDENSATE * 57 WIRING DIAGRAM TUBE, DRAIN RAIN GUTTER TUBE, CONDENSATE DRAIN TUBE, DRAIN CONDENSATE TRAP BRACKET, IGNITOR * 62 TUBE, DRAIN CONDENSATE PAN PIPE EXHAUST VENT
7 7 of Rev. D (302) FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL MODEL NO. DESCRIPTION USED WITH 1NP0347 ALL MODELS EXCEPT 140 MBH PROPANE (LP) CONVERSION KIT 1NP MBH 1CT0302 CONCENTRIC INTAKE/VENT 2 40, 60, 80, 100 INPUT MBH 1CT0303 CONCENTRIC INTAKE/VENT MBH 1PS0306 1PS0307 1PS0308 HIGH ALTITUDE PRESSURE SWITCH KIT FOR APPLICATION INFORMA- (Does Not Include Orifices) TION SEE FORM N2.1V 1PS0309 1PS0310 1BR /2 CABINETS 1BR /2 CABINETS EXTERNAL BOTTOM FILTER RACK 1BR CABINETS 1BR /2 CABINETS 1NK0301 CONDENSATE NEUTRALIZER KIT ALL MODELS FIELD INSTALLED ACCESSORIES - ELECTRICAL MODEL NO. DESCRIPTION USED WITH 2TH TH TB THERMOSTAT- One-stage heat/cool. Manual changeover, integral subbase. System Switch: Cool-Off-Heat. Fan Switch: Auto-On. THERMOSTAT- One-stage heat. Deluxe 24V with heat only subbase, does not include fan switch. For one-stage cool or one-stage heat/cool, must be used with subbase 2tb SUBBASE (24V) - One-stage heat/cool. Manual changeover, integral subbase. System Switch: Cool-Off-Heat. Fan Switch: Auto-On. ALL P3U MODELS 2ET THERMOSTAT- One-stage heat/cool.programmablel changeover, with subbase. System Switch: Cool-Off-Heat. Fan Switch: Auto-On. 6TH THERMOSTAT- Heating, One-stage heat, No Fan Switch. 6TH THERMOSTAT- Heating/Cooling, One-stage heat/cool. ALL G9T,FG9 MODELS Manual changeover. 2CT TWINNING CONTROL ALL MODELS Unitary Products Group
8 8 of 8 TO ORDER AUTHORIZED FACTORY REPLACEMENT PARTS - Contact your Source1 HVAC Parts Distributor or visit our website at for a Distributor and Dealer listing. Subject to change without notice. Printed in U.S.A Rev. D (302) Copyright by York International Corp All rights reserved. Supersedes: Rev. C (1201) Unitary 5005 Norman Products York OK Group Drive 73069
2 STAGE UPFLOW NATURAL GAS FURNACES (94+)
2 STAGE UPFLOW NATURAL GAS FURNACES (94+) HVAC SERVICE PARTS Supersedes: 035-17482-000 Rev. E (1102) 035-17482-000 Rev. F (0304) 1 of 8 Figure 1: 2-STAGE UPFLOW NATURAL GAS FURNACES (94+) P1XUB12N05501
More informationFG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%)
FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%) www.source1parts.com HVAC SERVICE PARTS Supersedes: 650.75-RP1U (1199) 035-17790-001 Rev. A (1102) 1 of 8 13 5 9 8 61 6 10 4 2 11 12 7 3 16 1 14 15
More informationPT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) Supersedes: 035-20487-001 Rev. C (1004) 035-20487-001 Rev. D (1014) 1 of 8 31 65 24 5 8 53 63 35
More informationPS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%
PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% HVAC SERVICE PARTS Supersedes: 035-20437-001 Rev. C (1004) 035-20437-001 Rev. D (1204) 1 of 8 Figure 1: UPFLOW 1-STAGE NATURAL GAS FURNACES (90%) FIG
More information2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%)
2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (See Page 6) HVAC SERVICE PARTS Supersedes: 035-17432-000 Rev. B (1201) 035-17432-000 Rev. C (0304) 1 of 8 Figure
More informationGM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)
GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20642-001 Rev. A (0904) 035-20642-001 Rev. B (0205) 1 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE
More informationPT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES
www.source1parts.com HVAC SERVICE PARTS PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES (STYLE D, Some B) INCLUDING LO-NOX MODELS Supersedes: Nothing 035-21348-001 Rev. A (0307) 1 of 8 8
More informationFC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) Supersedes: 035-20615-001 Rev. C (1004) 035-20615-001 Rev. D (0507) 1 of 8
More informationGF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G)
www.source1parts.com HVAC SERVICE PARTS 32 GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) Supersedes: 035-20372-001 Rev. D (0205) 035-20372-001 Rev. E (0507) 74 1 of 12 Figure 1: UPFLOW CONDENSING
More informationFC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%)
FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (MODEL LC8) (STYLE B) HVAC SERVICE PARTS Supersedes: 035-20671-001 Rev. C (0605) 035-20671-001 Rev. D (1105) 1 of 8 Figure
More informationPS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20712-001 Rev. B (1005) 035-20712-001 Rev. C (1105) 1 of 12 Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM
More informationPS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-21082-001 Rev. A (1205) 035-21082-001 Rev. B (1106) 1 of 12 31 29 5 61 26 10 39 69 12 11 16
More informationP3HU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) (STYLES A & B, INCLUDING LOW NOX)
www.source1parts.com HVAC SERVICE PARTS PHU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (0%) (STYLES A & B, INCLUDING LOW NOX) Supersedes: 0-1-000 Rev. C (06) 0-1-000 Rev. D (0) 1 of 1 1 1 1 1 6,0 Figure
More informationGM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)
GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-21295-001 Rev. A (1206) 1 of 12 31 29 26 5 10 39 69 24 11 12 16 58 61 40 13
More informationGM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20716-001 Rev. A (0205) 035-20716-001 Rev. B (1005) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationGM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)
www.source1parts.com HVAC SERVICE PARTS GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) Supersedes: 035-21080-001 Rev. D (0207) 035-21080-001 Rev. E (0507) 1 of 12 31 29 26 5 10 39 69 24 11
More informationPT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20714-001 Rev. C (1005) 035-20714-001 Rev. D (1105) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationFL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) Supersedes: 035-21211-001 Rev. C (1106) 035-21211-001 Rev. D (0708) 1 of 8 33 31 5 10 41
More informationPT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)
PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20700-001 Rev. B (0805) 035-20700-001 Rev. C (1105) 1 of 8 Figure 1: DOWNFLOW/HORIZONTAL 2-STAGE
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. A (0313) 035-23623-001 Rev. B (0613) 26 1 of 6 44
More informationFC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) Supersedes: 035-21088-001 Rev. B (0806) 035-21088-001 Rev. C (0507) 1 of 8 31
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. H (1115) 035-23623-001 Rev. J (1117) 26 1 of 6 44
More informationP1DD AND G8D 2-STAGE DOWNFLOW - NATURAL GAS FURNACES (80%)
P1DD AND G8D 2-STAGE DOWNFLOW - NATURAL GAS FURNAES (80%) HVA SERVIE PARTS Supersedes: 035-17433-000 Rev. (0404) 035-17433-000 Rev. D (0604) 1 of 8 Figure 1: 2-STAGE DOWNFLOW NATURAL GAS FURNAES (80%)
More informationFC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) Supersedes: Nothing, See Back 035-21322-001 Rev.
More informationGM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)
www.source1parts.com HVAC SERVICE PARTS GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) Supersedes: 035-21326-001 Rev. A (0207) 035-21326-001
More informationPC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) Supersedes: 035-214-001 Rev. B (0706) 035-214-001 Rev. C (1006)
More informationTG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS
www.source1parts.com HVAC SERVICE PARTS 41 TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS Supersedes: 035-21389-001 Rev. K (0410) 035-21389-001
More informationTECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.
036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R
More informationAHP SERIES SINGLE PIECE AIR HANDLER R-22 TXV AND FLEX COIL MODELS (STYLE A&B)
www.source1parts.com AHP SERIES SINGLE PIECE AIR HANDLER R-22 TXV AND FLEX COIL MODELS (STYLE A&B) HVAC SERVICE PARTS Supersedes:03-21126-001 Rev. E (0408) 03-21126-001 Rev. F (0609) 1 of 8 12 4 3 6 7
More informationDDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)
www.source1parts.com HVAC SERVICE PARTS DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) Supersedes:035-23383-001 Rev. A (1211) 035-23383-001 Rev. B (0112) 1 of 14
More informationTECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES
036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationGUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal
REPLACEMENT PARTS LIST GUH & GDD SERIES SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES NON-CONDENSING GAS FURNACES CONDENSING GAS FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE GUH80A Upflow / Horizontal
More informationTECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE
TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: P*XU/ G9D-UP Two Stage (Upflow) EFFICIENCY RATING CERTIFIED This product was manufactured in a plant
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: GY8S / GM8S / LY8S / LM8S / LF8 (Single Stage Upflow / Horizontal / LoNOx) EFFICIENCY RATING CERTIFIED
More informationRP8.1Y (ERRATA 1) (202) 2 of 8
530.18-RP8.1Y (ERRATA 1) (202) 2 of 8 ELECTRICAL (Cont.) FIG ITEM DESCRIPTION D6CG048N06006A D6CG048N06025A D6CG048N06046A D6CG048N06058A 3-BURNER 3-BURNER 3-BURNER 3-BURNER * 15 CONNECTOR, CAP (9-CIRCUIT)
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........
More informationGV Series 4 Section Assembly
GV Series 4 Section Assembly 192 Current Service Parts GV Series 4 Section Assembly Fig. No. Part No. Description Size Notes 1 322-200-280 Section Assembly, GV-3 (Repair Kit Required) 3 1 322-200-281 Section
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATION, MAINTENANCE AND SERVICE MANUAL MODELS: G8C/ GF8 (Single Stage Multi-Position) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System CONTACT INFORMATION...............................
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATION, MAINTENANCE AND SERVICE MANUAL MODELS: PC9 (Modulating Downflow/Horizontal With ECM Motor) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System CONTACT INFORMATION................................
More informationMASTERTEMP HEATER REPLACEMENT PARTS
0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available
More informationG71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped
More informationGAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)
FORM NO. G22-482 REV. 8 Supersedes Form No. G22-482 Rev. 7 GAS FURNACES RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) 90 PLUS WITH DUAL COMFORT CONTROL
More informationG60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE
More informationSKYPAK II Heating & Cooling Self Contained Packages
SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation
More informationOWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES
OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES TABLE OF CONTENTS HOW YOUR GAS FURNACE WORKS...................... 2 KEEP THE FURNACE AREA CLEAR....................... 2 SFOR YOUR SAFETY,
More informationGAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES
FORM NO. G11-493 REV. 5 Supersedes Form No. G11-493 Rev. 4 GAS FURNACES RGRL- SERIES Models with Input Rates of 45,000, 60,000, 75,000 & 90,000 BTU/HR [13.19, 17.58, 22, & 26.38 kw] 90 PLUS WITH DUAL COMFORT
More informationCooling Capacity CFM range
R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and
More informationGAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G66-452 REV. 3 Supersedes Form No. G66-452 Rev. 2 GAS FURNACES WGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (U.S. & Canadian Models) (All Models 90% A.F.U.E.
More informationCooling Capacity CFM in. w.c. (125 Pa)
R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning
More informationREPLACEMENT PARTS LIST
REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals
More informationParts List for Ener-Radiant XL Tube Heaters
Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G66-477 Supersedes Form No. A11-152 Rev. 3 90 EFFICIENCY UPF GAS FURNACES 90RJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above)
More informationCOMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES
FORM NO. GSC-493 REV. 3 Supersedes Form No. GSC-493 Rev. 2 GF902U*B SERIES Models with Input Rates of 45,000, 60,000, 75,000, 90,000 & 105,000 BTU/HR [13.19, 17.58, 22, 26.38 & 30.77 kw] 90 PLUS WITH DUAL
More informationGAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G11-503 REV. 1 Supersedes Form No. G11-503 GAS FURNACES Visit www.rheem.com for complete details. RGRC- SERIES Model with Input Rates from 45,000 to 105,000 BTU/HR [13.19 to 30.77 kw] (All Models
More informationTZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )
FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features
More informationGAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-452 REV. 10 Supersedes Form No. G11-452 Rev. 9 GAS FURNACES RGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC
More informationT9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)
T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion
More informationKG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace
More informationSECTION I: USER S INFORMATION
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: GY9S*UP / GM9S*UP / GF9S*UP (Single Stage Upflow) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality
More informationGAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G11-450 REV. 13 Supersedes Form No. G11-450 Rev. 12 GAS FURNACES /RGRB- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC
More informationH9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)
H9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe). Direct Vent Furnace 4 high with wider cabinets, for noise reduction and ease of installation. Factory shipped as natural
More information27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev.
27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/2014 2014 Whirlpool Corporation Part W10710285 Rev. A TOP AND CONSOLE PARTS 05/13/2014 2 Part W10710285 Rev. A TOP AND CONSOLE
More informationMcQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016
Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationGAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A
GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/2016 2016 Maytag Part W10884161 Rev. A TOP AND CONSOLE PARTS 05/24/2016 2 Part W10884161 Rev. A TOP AND CONSOLE PARTS Part Description
More informationW92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )
FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential
More informationRuud Achiever Series Multi position Gas Furnaces
Gas Furnaces Ruud Achiever Series Multi position Gas Furnaces R92P- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationFORM NO. G REV. 4 Supersedes Form No. G Rev. 3
FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace
More informationTZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )
FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. GSC-497 REV. 2 Supersedes Form No. GSC-497 Rev. 1 GF901U SERIES Models with Input Rates 45,000, 60,000, 105,000 & 120,000 BTU/HR [13.19, 17.58, 30.77, & 35.17 kw] (All Models 90% A.F.U.E. or Above)
More informationRheem Classic Series Downflow/ Horizontal Gas Furnaces
Gas Furnaces Rheem Classic Series Downflow/ Horizontal Gas Furnaces RGTC- Series Up to 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationTZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )
FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........
More informationMERIT SERIES Downflow
PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL
More informationG60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0124 L11 Revised 11 2006 G60UHV(X) G60UHV(X) SERIES UNITS G60UHV(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with
More information80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The
More information90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)
FORM NO. G66-480 Supersedes Form No. G66-480 Rev. 0 90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/ HORIZONTAL
More informationEffective october 14, 2014
COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More information27" GAS DRYER MODELS: MGD7100DW0 (White) MGD7100DC0 (Chrome Shadow) 05/08/ Maytag Part No. W Rev. A
27" GAS DRYER MODELS: MGD7100DW0 (White) MGD7100DC0 (Chrome Shadow) 05/08/2014 2014 Maytag Part W10712329 Rev. A TOP AND CONSOLE PARTS 05/08/2014 2 Part W10712329 Rev. A TOP AND CONSOLE PARTS Part Description
More informationFEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).
This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency
More informationGAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL
FORM NO. G11-499 Supersedes Form No. G11-499 GAS FURNACES RGFE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Equipped with Comfort
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: PV8*DH/FL8V*DH/FC8V*DH/LL8V*DH/LC8V*DH (Variable Speed Downflow/Horizontal/Low NOx) EFFICIENCY RATING
More informationThis parts list is current as of the above revision date. See for the current revision.
URM- Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-urm-.pdf for the current revision. Package Gas-Electric Table of Contents Model Explanation...................................................................................................................
More information29" GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/ Maytag Part No. W Rev. A
29" GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/2013 2013 Maytag Part W10624907 Rev. A TOP AND CONSOLE PARTS 07/02/2013 2 Part W10624907 Rev. A TOP AND CONSOLE PARTS Part Description
More informationModel GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES
SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven
More informationMULTI POSITION GAS FURNACE
FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design
More informationZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG
More information27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A
27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/2013 2013 Maytag Part W10617393 Rev. A TOP AND CONSOLE PARTS 05/31/2013 2 Part W10617393 Rev. A TOP AND CONSOLE PARTS Part Description
More informationG61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.
P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000
More informationWt. Lbs Model Number (BTUH) Hz
Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR
More informationMulti-Position Gas Furnaces
MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace
More informationMULTI POSITION GAS FURNACE
FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all
More informationG I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY
G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationnufacturing Company, L.P San Felipe, Suite 500
REPAIR PARTS GMPN Multi-Positional Gas Furnace GMPN040-3 GMPN060-3 GMPN080-4 GMPN100-4 GMPN120-5 nufacturing Company, L.P. San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to be
More informationG60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with
More informationRAYPAK ILLUSTRATED PARTS LIST
RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options
More informationTOP AND CONSOLE PARTS For Models: LGQ9858PW0, LGQ9858PG0 (White/Grey) (Biscuit/Gold)
TOP AND CONSOLE PARTS 29"GAS DRYER 5 04 Litho in U.S.A. (djc) 1 Part No. 1 Literature Parts LIT8535830 Instructions, Installation LIT8533770 Sheet, Cycle Feature LIT8522243 Use & Care Guide LIT3406661
More information90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-498 REV. 5 Supersedes Form No. G11-498 Rev. 4 RGTS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/
More information