1 Pellet Boilers Instructions for Use and Maintenance - THE PRESENT MANUAL FORMS AN INTEGRAL PART OF THE BOILER AND MUST BE KEPT FOR FUTURE REFERENCE Bmax Technology - a Division of Elmec Group S.r.l. Localition Cà D Oro Asigliano Veneto (VICENZA) - ITALY Elmec Group S.r.l. Tax Code and VAT no.: BEFORE USING THE BOILER IT IS OBLIGATORY TO READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS

2 Declaration Of Conformity NOTES Elmec Group S.r.l. Location: Cà D Oro Asigliano Veneto (VICENZA) - ITALY Declares that the BOILER: SPACE FOR MACHINERY IDENTIFICATION PLATE Conforms to the Following European Standards and Directives: Directive UNI EN 303-5:2012 (Heating Boilers for Solid Combustion Up to 500 kw) Directive UNI EN 15270:2008 (Pellet Burners for Small Boilers for Heating) Directive 2004/108/CE (Electro-Magnetic Compatibility) Directive 2006/95/CE (Low Voltage) Regulation EU 305/11(Fixes the Harmonised Conditions for Sale of Manufactured Products) Directive 2006/42/CE (Machinery Directive) ANY MODIFICATION OF THE BOILER WITHOUT THE PRIOR CONSENT OF Elmec Group S.r.l. WILL RENDER THIS DECLARATION NULL AND VOID Date 01/02/2014 Managing Director : Bmax Technology - a Division of Elmec Group S.r.l. Localition Cà D Oro Asigliano Veneto (VICENZA) - ITALY Elmec Group S.r.l. Tax Code and VAT no.: Rev. 00 Date 28/05/2014

3 NOTES PRESENTATION Dear Customer, We thank you for choosing our product. The B-max Pellet Boilers can be connected to any type of heating system: to Radiators - Floor Skirting, etc.. Our boilers have been exclusively studied to operate with wood pellets (DIN quality 6 mm. diameter. Its structure is similar to a traditional wood boiler, but it is far more economical. It is extremely efficient, with an air-cooled steel door, minimal maintenance requirements and a long life cycle. With this manual you can learn to use your boiler correctly. We therefore ask you to read it completely and very carefully before using it. 20 1

4 INDEX WARRANTY GENERAL INDEX SAFETY GENERAL WARNINGS SAFETY WARNINGS FOR THE USER PURPOSE OF THE MANUAL RESPONSIBILITY OF THE MANUFACTURER CHARACTERISTICS and TECHNICAL DATA MANUFACTURING CHARACTERISTICS BRIEF OF THE PARTS AND CONNECTIONS SIZES TECHNICAL DATA CHART INSTALLATION RESPONSIBILITIES OF THE INSTALLER SMOKE EXHAUST LOCATION INSTALLATION ELECTRICAL CONNECTIONS CONNECTION TO HEATING SYSTEM INSTALLATION OF BURNER ON BOILER START-UP PRELIMINARY OPERATIONS INITIAL START-UP AND SHUT-DOWN TRANSPORT and MAINTENANCE TRANSPORT CLEANING WEEKLY MAINTENANCE SPECIAL MAINTENANCE WARRANTY WARRANTY CONDITIONS WARRANTY WARRANTY 6.1 WARRANTY CONDITIONS To be able to use the Legal Guarantee, as per EEC directive CEE 1999/44/E (D/Lgs. 42/2002) the CONSUMER must scrupulously observe the requirements indicated in the present Manual, and in particular, must: Never use the system for purposes other than those indicated in this manual. Always carry out constant, diligent Maintenance as indicated in the various chapters. Follow the safety regulations currently in force in the state in which the boiler is installed. Never tamper with the plant Only use genuine spare parts Ensure that the installation of the boiler is carried out by a qualified technician or by someone with experience in compliance with the instructions given in this manual Only and exclusively use Pellets as fuel, of the type indicated previously in this manual. Consistently carry out the necessary maintenance as indicated in the various chapters in a diligent manner; 6.2 GUARANTEE This product is Guaranteed for 2 (Two) YEARS from the date of purchase and the Guarantee covers all the defects and faults that can be attributed to proven production and material problems. During the guarantee period the company BMax will replace and repair free of charge any pieces that are shown to be defective from the moment of purchase. THE FOLLOWING ARE EXCLUDED FROM THE GUARANTEE: All damage caused during transport. We therefore advise customers to check the machine carefully when it arrives and immediately inform the retailer of any damage that may have occurred; Damage caused by atmospheric, chemical and electrochemical agents; All parts that are subject to normal WEAR. No compensation will be awarded for any periods during which the product is not working efficiently. BMax is not liable for any errors that this manual may contain and is free to vary the characteristics of its product without prior warning 2 19

5 MAINTENANCE SAFETY 5.4 SPECIAL MAINTENANCE Cleaning the Heat Exhangers: 1. Open all 3 doors as shown in the diagram 2. Scrape the exchangers indicated with the arrow (1) using the special brush supplied with the boiler 3. Vacuum out the ask from the ash pan, as shown by the arrow (2) 1.0 SAFETY 1.1 GENERAL WARNINGS!! CHECK THAT THE CHIMNEY FLUE HAS SUFFICIENT DRAW BEFORE CONNECTING IT TO THE SMOKE EXHAUST ON THE BOILER Always use the safety devices and individual protection devices required in accordance with EEC Directive 89/391 Disconnect the power supply before carrying out any operations. Always use suitable tools. Before starting any work, make sure that the combustion chamber is cold and that the ash is cold. Also wait for the opening handles to cool down before touching them No inflammable material should be stored near the Boiler!!!CAUTION No modifications to the Boiler may be made without written consent from the manufacturer Only use original spare parts or parts approved by the manufacturer to avoid possible damage to the Boiler Do not open the Boiler doors while the burner is working Check for the presence of condensation: this is the sign of possible water infiltrations or of exhaust cooling. It is advisable to identify the possible causes to restore correct functioning DO NOT USE the Boiler if even one part is defective or is not working Always clean the combustion brazier of the burner before ignition (See Burner manual) 18 3

6 SAFETY MAINTENANCE 1.2 SAFETY WARNINGS FOR THE USER 5.4 SPECIAL MAINTENANCE The place where the boiler will be installed, hereby known as the installation location, MUST be installed in accordance with local, national and European regulations. The boiler is for heating and during operation its external surfaces are very hot. During operation, we recommend maximum caution and in particolar: Do not get too close to and do not touch the doors: DANGER OF BURNS By Special Maintenance, we mean all the checking, cleaning and maintenance operations that should be carried out at least twice a year. These operations should be carried out both on the Boiler and on the Burner by qualified technicians with the training required by law. For maintenance of the Burner see the respective manual. CAUTION! Before starting any maintenance work, check that the plant is disconnected from the mains supply. Do not get too close to and do not touch the smoke exhaust: DANGER OF BURNS Do not carry out any cleaning when the boiler is On Do not open the doors of the Boiler with the burner on Do not remove the ash Do not let Children or Animals go near the boiler OBEY ALL THE RULES SET OUT IN THIS MANUAL Plus, to use the Pellet Boiler correctly: Only use the fuel which conforms to the manufacturer s recommendations Observe the maintenance programme Carry out periodic clearing (only with the Boiler off and when the ash is cold) Do not use in the event of malfunctioning and anomalies Do not throw on water, not even to put out the fire in the burner brazier Do not turn off the Boiler by pulling out the plug from the socket (first turn off the burner and let it go through the shut-down cycle, then remove the plug from the main supply) Do not use wood or coal, only Pellets with the following characteristics: diam. 6 mm. - max. length 30 mm. - humidity 8-9 % Do not use the Boiler as an incinerator Carry out all operations with the maximum concern for safety Check the gaskets on the boiler and substitute them if damaged Check the seals on the 3 doors Check the condition of the electric cables and their connections to the burner Check that the safety valve is working correctly (this should be done every 3 months) Analyse the combustion and record the data on the last pages of this manuel in the NOTES tables. Make a note of any components replaced on the same tables. Check the connection between the smoke duct and the chimney Clean out the chimney Remove the external pannelling and clean the body of the boiler Check all the connections of the hydraulic parts Clean out the inside walls of the boiler, both vertically and horizontally, and clean the heat exchangers situated in the upper part of the boiler (See the diagram on Page 18). This should be carried out using the specific brush supplied with the boiler. 4 17

7 MAINTENANCE SAFETY 5.3 WEEKLY MAINTENANCE Weekly maintenance involves cleaning the ashes and combustion residues from inside the ash pan of the Boiler and in the Burner. This should be done at least every 2/3 days MAX, but can be more or less frequent according to the quality of the Pellets used. Remember also that cleaning frequently inside the combustion chamber positively affects the general yield of the Boiler. During this phase use any ash vacuum cleaner that is equipped with a filter to prevent the dust that is sucked in from returning into the environment. Begin as indicated below: Switch off the machine and disconnect the power supply Check that the machine has stopped and wait for it to cool. Open the door of the Boiler, using the handle indicated below. 1.3 PURPOSE OF THE MANUAL The purpose of this manual is to allow the user to take all possible, necessary measures and to set up all the machinery and materials in such as a way as to ensure the correct and safe use of the equipment. The present manual is in conformity with the latest regulations at the time of release onto the market. It does not consider the machinery already on the market with its relative tecnical documentation, deficient or inadeguate, if eventual modifications or adjustments or are made or new technologies on new machines on the market are applied. The information in this manual must be scrupulously evaluated and observed, and is all necessary for the correct installation, use and maintenance of the boiler. Therefore, this manual must be carefully stored for consultation, any time there are doubts or problems. The use and instructions manual is an integral part of the boiler equipment. If the boiler is sold to another person, it is obligatory to consign the manual to the new purchaser. If it is lost, it is possible to request a new copy from the manufacturer. 1.4 RESPONSIBILITY OF THE MANUFACTURER On consignment of this manual, BMax declines all responsibility, either civil or criminal, direct or indirect, due to: Suck in the dust from the ash space and the brazier of the burner as shown in the figure Accidents caused by the NON OBSERVANCE of the regulations and specifications present in this manual Accidents caused by an IMPROPER AND INCORRECT USE of the machinery on the part of the user Accidents caused by modifications and repairs carried out by technicians that are not authorised by BMax Inadequate MAINTENANCE Exceptional events Accidents caused by the use of non-original spare parts or parts that are not specific to the model in question For installation operations, the installer is, and remains, solely responsibile. 16 5

8 TECHNICAL MAINTENANCE 2.0 CHARACTERISTICS AND TECHNICAL DATA 2.1 MANUFATURING CHARACTERISTICS 5.0 TRANSPORT and MAINTENANCE 5.1 TRANSPORT The Boiler is delivered on a pallet and protected with bubble wrap, or in a wooden box for larger models. BOILER BODY The internal burning area is constructed in P - 265GH, thickness 3 and 5 millimetres, while the external casing is in S235 JRG2. The heating water flows through the heat exchanger, which is placed in the upper part of the boiler. The boiler is constructed with water tight welding, and the welding is tested twice by our quality control system at a pressure of 4 bars. DOORS The boiler body has 3 doors to aid efficient working aid cleaning. The three doors are air cooled and are built in steel in 3 layers: respectively, 1.5, 3 and 5 millimetres. The sealing of the doors is guaranteed by means of a glass-fibre fire-retardant seal, placed between the boiler body and the doors. The upper door aids cleaning of the heat exchangers, the central door permits the connection of one of our pellet burners to the boiler by means of the special flange. The lower door allows the cleaning of the ashes produced by the combustion in the burner. The 3 doors are fitted with handles in special anti-overheating plastic material. COVER The boiler body is insulated externally with rock wool, thickness 30 millimetres, and the external pannelling is constructed in sheet metal, thickness 0.8 millimetres. This is covered with electrostatic powder and is screwed to the boiler body. CONNECTIONS The supply and return flow connections to the heating plant are built with 1 1/2 BSP threading, while the filling/emptying connection and the safety valve or pressure gauge are built with 1/2 BSP threading. Transport, loading and unloading Transport, loading and unloading must be carried out with care to avoid damaging the machinery and to protect people, animals and things. For loading and unloading the Boiler, a fork lift with sufficient capacity on the basis of the safety co-efficient (see the gross weight of the Boiler in the TECHNICAL DATA TABLE contained in paragraph 2.4 on page 9 of this manual). During these operations the centre of gravity of the machinery must remain in a central position to keep the load balanced and stable, thus avoiding dangerous inclinations. After having removed the packaging, check that the machinery is undamaged. In case of doubt, immediately contact the agent concerned. The Boiler should appear solid and compact. Packaging Material The packing material (wood, cardboard, polystyrene, nails, etc.) must be collected and disposed of according to current legislation in force. CAUTION! Keep this material out of the reach of children; it can be a source of DANGER. Once the packing has been removed, position the Boiler as shown in paragraph 3.3 POSITIONING on page 11 of the present manual. 5.2 CLEANING THE MACHINE Periodically check the efficiency of the hydraulic plant and the correct functioning of the safety valve.. Keep the machinery clean, avoiding the accumulation of dirt on the machine body. Periodically carry out the following operations, making sure the machine is disconnected from the mains, and that it is cold. Clean the external body regularly, using a soft, damp cloth and a non-toxic, solvent-free detergent. Rub gently, being careful not to press excessively. (DO NOT AIM JETS OF WATER OF ANY TYPE, NOT EVEN INDIRECTLY, ON THE BOILER AND BURNER.) DO NOT USE SOLVENTS If there are any unusual sounds or vibrations, check that all the screws and bolts are tight

9 TECHNICAL TECHNICAL 4.0 START-UP 4.1 PRELIMINARY OPERATIONS 2.2 BRIEF OF THE PARTS AND CONNECTIONS Before starting the Boiler, the installer must carry out the following checks: Make sure that all the electrical connections have been carried out following the instructions given in the Burner Manual. Make sure that the smoke outlet is thermally sealed. Make sure that the intake and delivery parts are free and not obstructed. Make sure that the burner is correctly fixed to the Boiler. Make sure that all 3 doors of the Boiler are closed correctly, so that the flame is only generated inside the combustion chamber. Make sure that the auger and the flaxible hose for connection to the burner have been connected and positioned correctly. Fill the container with Pellets only, and not with any other fuel. Check that the safety valve is connected and working correctly. Inform all users about the relative risks and dangers, and also train them about how the Boiler works. N.B.= the checks indicated above must also be carried out by the User or Maintenance Technician following any type of maintenance operation that caused the systems to be disconnected, or after intervening on the safety devices or on parts of the Boiler or Burner 4.2 FIRST START-UP AND SHUT-DOWN When starting for the first time, some of the oil and grease that coat the combustion chamber will tend to evaporate. The room must be aired to allow these fumes to exit. For the Start-Up, proceed as follows: 1) Make sure that the Boiler is connected to the Hydraulic system 2) Connect the Burner to the mains 3) Ignite the Burner; for ignition, see the BURNER MANUAL and follow the instructions. The burner electronic board ignites the flame and keeps it constantly under control, The board also monitors any problems that may appear on the burner display To SOLVE possible PROBLEMS, consult the BURNER MANUAL. To shut down the Boiler, it is sufficient: first, to turn off the burner, wait for the cooling cycle to be completed, and once it is finished, disconnect the Burner from the mains. 1) Boiler Body 2) External Pannelling 3) Heating Plant Return Outlet 4) Heating Plant Loading/Unloading Pipe 5) Upper Door 6) Ash Deposit Area 7) Central Door 8) Lower Door 9) Burner Support Flange 10) Door Handles 11) Combustion Chamber Area 12) Heat Exchanger 13) Safety Valve or Pressure Gauge 14) Smoke Exhaust Pipe 15) Heating Plant Supply Outlet 14 7

10 TECHNICAL TECHNICAL 2.3 DIMENSIONS 3.7 INSTALLING THE BURNER ON THE BOILER For questions of size, distance and safety, the Burner is supplied separately from the Boiler. To install the Burner, follow the instructions below: 1. Insert the support collector (2) onto the 4 M8 pins (1) welded onto the Boiler door 2. Fix on the collector (2) using the M8 nuts (3) 3. Completely insert the burner into the collector (2) 4. Fix the M6 nuts (5) 5. Insert the flexible Pellet feeder tube of the auger to the connection tube (6) 6. For the electrical connections of the auger and the Burner SEE THE BURNER MANUAL ONCE THE BURNER IS FIXED ON, IT MUST REMAIN IN A HORIZONTAL POSITION 8 13

11 TECHNICAL TECHNICAL 3.4 INSTALLATION The user is fully responsible for the work carried out or still to be carried out in the installation area. Before starting assembly operations, the installer must adhere to the safety precautions required by law and, in particular: must ensure that the provisions for the system comply with local, national and European laws Must check if specific authorisation is required because of urban, architectural and fire prevention regulations ; Must scrupulously follow the instructions given in this manual, above all paragraphs (3.1) on page 10 and ( ) on page 11 Must always use the personal protective devices and all the protective means required in compliance with current legislation in force. 3.5 ELECTRICAL CONNECTION The BMax boiler does not need any electrical connection, but the burner does (SEE THE BURNER MANUAL). These electrical connections must be carried out by a specialised, qualified technician who is authorised to work, in line with current legislation in force. 3.6 CONNECTION TO THE HEATING PLANT Choice of the correct size of the boiler and the heating plant, as well as the choice of the type of plant to be realised, are the responsibility of the installer and/or the designer. It is advisable to connect the machinery to the heating system by means of a three-piece joint, in order to be able to remove it without causing damage in the event of malfunctioning, in particular, to the return flow connection. In fact, it could be useful to install a T-junction with a stop cock to be able to drain the plant for maintenance work. For correct functioning of the plant it is advisable to use a mixing valve set at 55 C as a way to regulate the temperature both of the plant and the boiler, and to be able to increase the temperature of the return flow into the boiler, in order to protect the parts from dangerous temperature drops caused by condensation in the flues. After having completed the connections to the hydraulic system, the heating plant and the boiler must be filled. Before this operation, it is necessary to check the hardness of the water and of water residue, and if needed, install (for example, if there is water with a fixed residue greater than 300 mg/ l at 180 C) a water softener before the entry point of the water supply pipe. This will ensure optimal conservation of the inside surfaces of the boiler body, but also of the whole heating plant. Briefly, the following operations are necessary for filling: open any sectioning valves on the plant; completely open all the bleeder valves on all the radiators, so that all the air can escape without leaving air bubbles; fill the system very slowly using the Drainage Connection (4) of the boiler (see Pg. 7) keeping the bleeder valves of the radiators open even when a trickle of water starts to run, again to ensure that no air bubbles are created. When the installation is completed, it is a good rule to keep checking the seals of the hydraulic connections for at least 2 or 3 days for any leakage. 2.4 TECHNICAL DATA TABLE MODEL B-MAX 25 B-MAX 50 B-MAX 100 B-MAX 200 B-MAX 300 Nominal Heating Power (kw) Heating Power Class (Class 5) (kw) Max. Heating Surface According to Type of Heating Plant (m³) Fuel Type , Pellet DIN Ø 6 mm l = 5-30 mm Yield (Fuel: Pellet) (%) Heating Plant Supply Flow Connection (") M 1" 1/ Heating Plant Return Flow Connection (") R 1" 1/ Size of Ash Deposit Area (L¹x h¹-mm) 235x x x x x400 Smoke Exhaust Tube Diameter (Ø) Height (h - mm) Width (L - mm) Depth (p - mm) Weight (kg) Water Volume (lt) Max. Operating Pressure (bar) Testing Pressure (bar) Max. Operating Temperature ( C) Smoke Draw Length (Pa) Combustion Area Size 600x235x x355x x560x x640x x890x1400 (h² x L² x p - mm) N Exchangers

12 TECHNICAL TECHNICAL 3.0 INSTALLATION 3.1 RESPONSIBILITY OF THE INSTALLER The installer is responsible for :,checking the chimney flue, the air vents and all the necessary actions for installing the boiler. The installer is also responsible for: ensuring that all the safety regulations required by the specific legislation in force in the state, region, province and city of installation are respected. The use is subordinated to the instructions contained in the present manual and all the safety regulations required by the specific legislation in force in the state, region, province, city where the boiler is installed must be complied to. The UNI Directive defines the responsibilities of the installer: the installer must verify: The type of plant to be installed The compatibility of the installation area with the machinery itself in that the minimum distances required by the manufacturer must be respected The manufacturer s requirements for the boiler regarding the smoke exhaust system regulations (smoke channels and chimney flues) The internal section of the chimney, the material in which it is constructed, the homogeneity of the section, the absence of obstructions The possibility of installing external air outlets and the sizes of existing ones The possibility of the co-existence of the boiler to be installed with pre-existing equipment If the checks are positive, the machine can then be installed, so long as the instructions supplied by the manufacturer and the regulations concerning safety and fire prevention are scrupulously observed. When the installation is completed, there must be a test start-up of the plant, for a duration of not less than 30 minutes, to check the general operational state of the equipment. 3.2 SMOKE EXHAUST The smoke duct and connection to the chimney must be made in compliance with standards and laws in force. The pipes used must be rigid, resistant to temperature and mechanical stress, and watertight The chimney must guarantee the minimum depression indicated by current technical standards, considering a Zero pressure at the connection point with the smoke duct. Unsuitable or badly-sized chimneys or smoke ducts can increase combustion noise and negatively influence the generator combustion parameters. Non-insulated outlet ducts are a potential source of danger. The joints must be sealed using material that is resistant to a minimum temperature of 350 C (e.g. fillers, rubber cement, silicon preparations). N.B.= Refer to the TECHNICAL DATA TABLE (paragraph 2.4) on page 9 for the size of the generator smoke duct. 3.3 POSITION The POSITION in which the boiler is to be placed must be checked/established by the system installer or by a qualified technician, and account must be taken of technical requirements and laws in force. To position the boiler correctly, make sure that : it is placed it on a surface that has been levelled and is able to support the weight; the MINIMUM distances indicated in the figures below are respected to allow correct air flow and to allow normal CLEANING and MAINTENANCE operations to be carried out; When the installation is completed and after the first start-up of the plant, the installer must consign the following documentation to the client: The machine use and maintenance manual (if not present inside the machinery) The necessary documentation in compliance with existing laws 10 11

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

BIX B-One 100 kw INSTALLATION GUIDE

BIX B-One 100 kw INSTALLATION GUIDE BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality.

More information

USER MANUAL ACQUAHOME 32 B BLU

USER MANUAL ACQUAHOME 32 B BLU USER MANUAL ACQUAHOME 32 B BLU Dear Customer, Thank you for preferring a T heating unit, a modern, high-quality product that is able to guarantee your maximum well-being for a long period of time, with

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město LISEO Insert European Standard Certification UNE EN-13229 inserts LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město 405 02 INTRODUCTION.4 1. GUARANTEE CONDITIONS.4 1.1. SAFETY WARNINGS....4 1.2. GUARANTEE

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město LISEO STOVES European Standard Certification UNE EN-13240 stoves LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město 405 02 INTRODUCTION.3 2 1. GUARANTEE CONDITIONS.3 1.1. SAFETY WARNINGS..3 1.2. GUARANTEE

More information

User and maintenance manual

User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS HIGHLY IMPORTANT. This manual and

More information

Instruction manual for downdraft hood

Instruction manual for downdraft hood Instruction manual for downdraft hood Model code: BODY / DD600BK - BODY / DD900BK BODY / DD600SS - BODY / DD900SS Contact Caple on 0844 800 3830 or for spare parts www.4caple.co.uk The symbol on the product

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Models: Verso 4G Hob As part of Parmco Appliances commitment to improving and updating product ranges, we reserve the right to alter, change and update technical

More information

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5

More information

VETO CLEANER 500 FLUE GAS CLEANER

VETO CLEANER 500 FLUE GAS CLEANER As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437

More information

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

AUTOMATIC GRANULAR ICE FLAKER

AUTOMATIC GRANULAR ICE FLAKER AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a

More information

MODULAR AUTOMATIC GRANULAR ICE FLAKER

MODULAR AUTOMATIC GRANULAR ICE FLAKER MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having

More information

GB User and maintenance manual

GB User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS VERY IMPORTANT This manual and

More information

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...

More information

GLEB Kitchen exhaust fan

GLEB Kitchen exhaust fan GLEB Kitchen exhaust fan Installation and Maintenance??.1.2013 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

Instructions for use

Instructions for use Instructions for use These instructions are also available on the website: www.kitchenaid.eu Important instructions for safety 4 Installation 6 Safeguarding the environment 6 Troubleshooting guide 7 After-sales

More information

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove HEATING TECHNIQUE Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: +385 40 372 600, fax: +385 40 372 611 TECHNICAL INSTRUCTIONS for regulation, use and maintenance of pellet stove CentroPelet

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Technical information. Remeha P200. Pressurized boiler. Heat output: kw Technical information Remeha P200 R e m e h a P 2 0 0 Pressurized boiler Heat output: 59-256 kw Remeha P 200 CONTENTS Preface 3 1. Description of the unit 4 1.1 General 4 1.2 Burners 4 2. Construction

More information

Corn Flame Energy Corn Stove Model 3000

Corn Flame Energy Corn Stove Model 3000 Corn Flame Energy Corn Stove Model 3000 Installation and Operation Guide Read thoroughly before starting installation Save this manual for future reference SAFETY NOTICE If this stove is not properly installed,

More information

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS PW1370TD 2 EN Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS 3 E3 E1 C3 A1-A2-A3-A4 B4 B1 B5 B2 C1 B3 D 1 4 1 2 3 4 5 6 7 Ø13

More information

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN To respected customer, We are very pleased for your trust and your decision to buy our product. You made a good choice,

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing

More information

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

INSTALLATION, COMMISSIONING AND OPERATING MANUAL INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical

More information

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE Carbel models: C-60 Plus C-70 Plus C-80 Plus C-100 Plus C-70 Plus Double-sided C-80 Plus Double-sided C-100 Plus Double-sided CARBEL C/ Ciudad de Cartagena,

More information

Instructions for use

Instructions for use Instructions for use These instruction shall be available on website docs.kitchenaid.eu Important instructions for safety 4 Installation 6 Safeguarding the environment 6 Troubleshooting guide 7 After-Sales

More information

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk

More information

Parts Available from

Parts Available from Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable

More information

Cooker Hood LA-72-CAN.

Cooker Hood LA-72-CAN. Cooker Hood LA-72-CAN EN www.luxairhoods.com WARNINGS Safety This equipment can be used by children aged 8 or more, people with physical, mental and sensory disabilities or inexperienced users it they

More information

PELLET BOILER BIODOM 33. Instructions for use, maintenance and installation

PELLET BOILER BIODOM 33. Instructions for use, maintenance and installation PELLET BOILER BIODOM 33 Instructions for use, maintenance and installation Version 1.0 / July 2017 We thank you for your purchase of Biodom boiler. We ask to thoroughly read instructions for use before

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL HOT WATER ELECTRIC WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.

More information

GUH90 90 cm Canopy Hood

GUH90 90 cm Canopy Hood User Manual for your GUH90 90 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of your

More information

Easyfire Standalone biomass pellet boiler

Easyfire Standalone biomass pellet boiler Easyfire Standalone biomass pellet boiler DESIGN Essential and pleasant AESTETIC, small size If the humanity is in balance with the resources of nature, the respect for the environment will be possible.

More information

Contents. 1. Instructions for safety and use 20

Contents. 1. Instructions for safety and use 20 Contents 1. Instructions for safety and use 20 2. Positioning in the counter top 21 2.1 Fixing to the supporting structure 21 2.2 Positioning the adhesive sponge 22 2.3 Positioning the fastening clips

More information

Contents authorised persons

Contents authorised persons Contents 1. INSTRUCTIONS FOR SAFE AND PROPER USE 4 2. POSITIONING OF THE HOB 6 3. GAS CONNECTION 10 4. ELECTRICAL CONNECTION 11 5. ADAPTATION TO DIFFERENT TYPES OF GAS 12 6. FINAL OPERATIONS 14 7. USING

More information

Group. Virtus Group GmbH Hüserstraße Hamm / Germany. Virtus s.r.l. via Milano 95/e Casteggio (PV) / Italy

Group. Virtus Group GmbH Hüserstraße Hamm / Germany. Virtus s.r.l. via Milano 95/e Casteggio (PV) / Italy Group Service Virtus s.r.l. via Milano 95/e 27045 Casteggio (PV) / Italy % +39 0 383890612 7 +39 0 383809601 w w w. v i r t u s n e t. e u Virtus Group GmbH Hüserstraße 53 59075 Hamm / Germany % +49 (0)2381/973

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions Please read these instructions carefully before installing and operating this appliance 1 Contents 1. Introduction

More information

PELLET BURNER PV 350

PELLET BURNER PV 350 PELLET BURNER PV 350 INSTRUCTION MANUAL v1.1 1 PRODUCT DESCRIPTION...3 2 SAFETY RULES...3 3 WARNINGS...4 4 INSTALLATION INSTRUCTIONS...5 4.1 BOILER REQUIREMENTS...5 4.2 PELLET CONTAINER...6 4.3 INSTALLATION

More information

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

Contents. 1. Instructions for safe and proper use Positioning of hob Attachment to support structure Electrical connection 22

Contents. 1. Instructions for safe and proper use Positioning of hob Attachment to support structure Electrical connection 22 Contents 1. Instructions for safe and proper use 19 2. Positioning of hob 20 2.1 Attachment to support structure 20 3. Electrical connection 22 4. Gas connection 23 4.1 Connection to LPG 24 4.2 Ventilation

More information

Hamlet 60 & 80 Wall Hood

Hamlet 60 & 80 Wall Hood Hamlet 60 & 80 Wall Hood Installation & User Instructions Please read these instructions carefully before installing and operating this appliance 1 Contents 1. Introduction 3 2. Health and Safety 3-4 3.

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB / GB 99-11-03/01 1-18 Index 1 WORKING AND FITTED DIMENSIONS 3 1.1 Oven size 60 cm 3 1.2 Maxioven 4 2 INSTALLING THE FITTED OVEN 5 3 FITTED GAS - INSTALLATION REQUIREMENTS 5 4 FIXING THE OVEN TO THE UNIT

More information

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE IST 03 C 202-01 ELBA DUAL INSTALLATION, USE AND MAINTENANCE GB Thank you for choosing our boilers. Please read these installation and maintenance instructions with care. Please note that the boiler must

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit Service instructions for contractors VIESMANN Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit VITOLADENS 300-T 1/2007 Please keep safe. Safety instructions Safety instructions

More information

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA PLUS DS Solar Solar storage cylinder EN Installation and Operation Manual GENERAL INFORMATION This - comprises pages. Rev. manual, Code ENGLISH General information

More information

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all

More information

ST1. Mod. USE AND MAINTENANCE MANUAL

ST1. Mod. USE AND MAINTENANCE MANUAL Mod. USE AND MAINTENANCE MANUAL 2 Use and Maintenance Manual ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

More information

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D CENTRIFLOW 3D Plug fan GMEC >> Installation and Maintenance air comfort CentriFlow 3D 2 Plug Fan CentriFlow 3D GMEC Installation and Maintenance Important Information, Safety notes, Technical Description

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209 TECHNICAL MANUAL Multifuel Stove Model EW1MF To be retained by the user for future reference Serial Number. Document EW1MF 0209 Thank you for purchasing an ACR Heat Products stove. The Earlswood stove

More information

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+ INSTALLATION AND OPERATING INSTRUCTIONS Ariterm 60+ CONTENTS General.... 2 Installation.... 4-5 Installation of temperature limit valve... 6 Measurements and connections... 7 Technical specifications and

More information

Cooking c o l l e c t i o n

Cooking c o l l e c t i o n Cooking c o l l e c t i o n Instructions for Use and Warranty Details RH60-600mm Fixed Rangehood RH90-900mm Fixed Rangehood ongratulations on the purchase of your new C appliance. This appliance has been

More information

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD EN Before using the appliance, please carefully read this manual! 2 3 min 450mm Electrical cookers min 650mm Gas cookers min 650mm Gas cookers

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Glass Chimney Hood. Installation & User Instructions Please keep for future reference Glass Chimney Hood Installation & User Instructions Please keep for future reference 4897549 4897556 Important Please read these instructions fully before installing or using These instructions contain

More information

BIO-SELECT BIO-SELECT PLUS INSTALLATION, USER AND MAINTENANCE MANUAL

BIO-SELECT BIO-SELECT PLUS INSTALLATION, USER AND MAINTENANCE MANUAL STEEL BOILER FOR HEATING BIOMASS SOLID FUEL BIO-SELECT BIO-SELECT PLUS INSTALLATION, USER AND MAINTENANCE MANUAL COD. 57605EN.02 THANK YOU FOR PURCHASING THIS PRODUCT! On behalf of LASIAN Tecnología del

More information

CTA15-2 warming drawer. operating and installation instructions

CTA15-2 warming drawer. operating and installation instructions CTA15-2 warming drawer operating and installation instructions Table of Contents GB-IE 1 PRECAUTIONS FOR USE...4 2 DISPOSAL INSTRUCTIONS - OUR ENVIRONMENT POLICY...5 3 SAFETY PRECAUTIONS...6 4 GET TO KNOW

More information

USE AND MAINTENANCE INSTRUCTIONS PELLET STOVE. Air Channelled Air Hydro Boilers

USE AND MAINTENANCE INSTRUCTIONS PELLET STOVE. Air Channelled Air Hydro Boilers USE AND MAINTENANCE INSTRUCTIONS PELLET STOVE Air Channelled Air Hydro Boilers Read instructions carefully before installation, use and maintenance. The instructions manual is an integral part of the product.

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo INSTALLATION, OPERATION AND MAINTENANCE Ariterm Vedo CONTENTS General...3 Installation...4-5 Laddomat 21 Connection diagram...6 Temperature control valve...7 About burning wood...8 Operation...9-11 Service

More information

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14 Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification

More information

Reseller Stamp for Warranty

Reseller Stamp for Warranty FORMING MACHINE PF PF 30 PF 33 PF 36 PF 40 PF 45 Reseller Stamp for Warranty The equipment is constructed and tested in accordance with the safety regulations indicated in the reference European directives.

More information

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves Installation & Operating Instructions Models: York Midi & Serrano Electric Stoves PLEASE NOTE THAT THIS APPLIANCE USES A MOTOR TO OPERATE THE FLAME EFFECT AND THAT IT MAY BE POSSIBLE TO HEAR IT WHERE THE

More information

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD EN min 450mm Electrical cookers min 650mm Gas cookers min 650mm Gas cookers 1a 1b 1c 2a 2b ELECTRICAL / GAS - 650mm 3a 3b 2 2 x 8 3c 3d 3e 3 0 1 2 3 L

More information

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Rigoletto 60,90 & 120 Built-In Cupboard Hood Rigoletto 60,90 & 120 Built-In Cupboard Hood Installation & User Instructions Please read these instructions carefully before installing and operating this appliance 1 Contents 1. Introduction 3 2. Health

More information

Installation & Manual. Model T-25

Installation & Manual. Model T-25 Installation & Manual TR Central Heating Stove With Solid Fuel Model T-25 Tested according to DIN EN 13240 For product efficiency and emission values, see the declaration of conformity! TABLE OF CONTENTS

More information

Leonardo 90 Wall Hood

Leonardo 90 Wall Hood Leonardo 90 Wall Hood Installation & User Instructions Please read these instructions carefully before installing and operating this appliance 1 Contents 1. Introduction 3 2. Health and Safety 3-4 3. Installation

More information

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE 29-10-2013 CAUTION Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE Service the stove COMPLETELY as described in this manual. Check the chimney pipe. BLOCKED FLUE MESSAGE

More information

MALVA Multiair 10 UP! S1

MALVA Multiair 10 UP! S1 INSTALLATION GUIDE EN PELLET STOVE MALVA Multiair 10 UP! S1 PART 2 - OPERATION AND CLEANING Instructions in English TABLE OF CONTENTS TABLE OF CONTENTS... II 13-FIRST START-UP...3 14-CONTROL PANEL...5

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18 INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG Page 1 / 18 CHAP 1 - INSTRUCTIONS TO PREVENT ACCIDENTS Keep this manual carefully to be able to refer to it in every case of need. Keep appliance

More information

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased

More information

Instructions Manual SHC520X - SHC700X

Instructions Manual SHC520X - SHC700X Instructions Manual SHC520X - SHC700X INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 7 MAINTENANCE... 8 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for

More information

USE AND INSTALLATION MANUAL

USE AND INSTALLATION MANUAL EN USE AND INSTALLATION MANUAL COD.8901113500 1. GENERAL INFORMATION... 4 1.1. Symbols used in this manual... 4 1.2. Proper appliance use... 4 1.3. Information to be provided to the user... 5 1.4. Technical

More information

DTG Eco / V130

DTG Eco / V130 ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

DH-Direct Fired Poultry Farm Diesel Heater

DH-Direct Fired Poultry Farm Diesel Heater DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or

More information

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer Instructions for Use Warming Drawer Bedienungsanweisung Wärmeschublade Notice d'utilisation Chauffe-vaisselle Gebruiksaanwijzing Servieswarmer Table of Contents GB-IE 1 PRECAUTIONS FOR USE...4 2 DISPOSAL

More information

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Rigoletto 60,90 & 120 Built-In Cupboard Hood Rigoletto 60,90 & 120 Built-In Cupboard Hood Installation & User Instructions Please read these instructions carefully before installing and operating this appliance 1 Contents 1. Introduction 3 2. Health

More information

MODEL 466 Radiant / Convector Gas Fire Black Beauty

MODEL 466 Radiant / Convector Gas Fire Black Beauty O W N E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep

More information

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance Solid fuel hot water boiler TKH 250-400 KW INSTRUCTIONS MANUAL for usage and maintenance Prhovacka bb 22310 Simanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 oce@termomont.rs www.termomont.rs April

More information

HYDROMIST LITE CARPET CLEANER OPERATOR MANUAL

HYDROMIST LITE CARPET CLEANER OPERATOR MANUAL HYDROMIST LITE CARPET CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk

More information

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future.

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future. INSTRUCTIONS FOR USE INSTALLATION...4 SAFEGUARDING THE ENVIRONMENT... 7 IMPORTANT NOTES... 7 BEFORE USING THE OVEN... 8 OVEN ACCESSORIES... 9 CARE AND MAINTENANCE... 10 TROUBLESHOOTING GUIDE... 12 AFTER

More information

Nabucco Island Hood. Installation & User Instructions. Please read these instructions carefully before installing and operating this appliance

Nabucco Island Hood. Installation & User Instructions. Please read these instructions carefully before installing and operating this appliance Nabucco Island Hood Installation & User Instructions Please read these instructions carefully before installing and operating this appliance 1 Contents 1. Introduction 3 2. Health and Safety 3-4 3. Installation

More information

INSTALLATION, USER AND MAINTENANCE MANUAL

INSTALLATION, USER AND MAINTENANCE MANUAL Domestic Solid Fuel Cooker With Boiler Ilaria Mod. 703T-G Ilaria Mod. 703T-GL Ilaria Mod. 703T-I Ilaria Mod. 703T-IL INSTALLATION, USER AND MAINTENANCE MANUAL Equipments built in conformity with European

More information

Whole Room Dryer WRD, WRD/110

Whole Room Dryer WRD, WRD/110 Whole Room Dryer WRD, WRD/110 User Instructions Whole Room Dryers CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8117-0000 Iss.1 12/06 Fig 1 Fig 2 Fig 3 Fig 4 CONTENTS Page 1 Product information...................4

More information

BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set.

BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set. BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number

More information

Incinerator Model A1600 -Oil

Incinerator Model A1600 -Oil Incinerator Model A1600 -Oil Operators Manual Important Failure to cure refractory Before using will void warranty (See refractory curing procedure) Tampering with orifices in the burner will void warranty

More information

Installation and Operating Instructions. Models: T4-12LOW-9IS

Installation and Operating Instructions. Models: T4-12LOW-9IS Installation and Operating Instructions Models: T4-12LOW-9IS Dear Valued Customer, Thank you and congratulations on purchasing your new Parmco appliance. All Parmco products are made to the highest quality

More information