Indiana WX Oil Furnace Inspection Guide
|
|
- Donald Craig
- 5 years ago
- Views:
Transcription
1 Indiana WX Oil Furnace Inspection Guide Client: Job # : Address: Phone: Client Interview: Oil Dealer: Date of last service: Comments/Billing information: Standard Inspection / Clean and Tune Follow-up: Emergency / Furnace Replacement Fuel Type: # 1 oil # 2 oil Forced air? Y N Water Heater: Gas Oil Electric Is this a mobile home? Y N Is the Water Heater in the same CAZ as the furnace? Y N Is this the Final Inspection of a new furnace installation? Y N Describe appliance types, locations, venting configurations and BTUH input ratings: 1
2 Inspect entire fuel delivery system/s and oil filter/s Inspect entire vent system and barometric damper Inspect electrical system Determine if adequate combustion and ventilation air is available Unsafe / Leaks Unsafe Unsafe Confined space Repaired leaks/piping problems Filter added Repaired vent system problems Damper replaced Repaired electrical problems Document repairs in comments section As a good visual inspection of the heat exchanger is a difficult thing to do, the use of a combustion analyzer or reliable heat exchanger test kit is highly recommended. Fuel Delivery System: Operational shut-off valve/s? Oil filter present? Oil filter cartridge replaced? No Vent System: Operational barometric damper? N/A Operational shut-off switch? Electrical polarity correct? Appliance grounded? Total BTUH BTUH Volume of air needed: (BTUH/20) Cu.Ft. Volume available: (LxWxH) Cu. Ft. Combustion air work done by others Fuel Delivery System: Vent system: Electrical system: Proper amount of combustion and ventilation air provided Visually inspect the integrity of the heat exchanger Test kit used? Analyzer used? Change with blower on: % Crack or hole Fail Replace furnace Crack or hole in the heat exchanger? Replace furnace. *Continue and complete all other appropriate sections of this document* 2
3 Clean the heat exchanger and seal any openings where scavenger air may enter Service burner Cleaned, and openings sealed? Heat exchanger cleaned? No Nameplate input rating: BTUH Nozzle information: Replaced? No Size: GPH Spray angle: Deg. Pattern: Clean CAD cell eye: Clean and adjust electrodes: Clean burner blower wheel: Oil motor: (if needed) Inspect combustion chamber: Burner serviced? No - Burner serviced? No Inspect the thermostat and set the heat anticipator. Measure amperage Repair, replace or adjust. Measured amperage at the thermostat: Amps Heat anticipator reset? No N/A Heat anticipator setting: Amps N/A Inspect the duct system Problems Make necessary repairs - Any open returns? No Ducts sealed? No N/A Duct sealing performed by others Any open returns? No Ducts sealed? N/A Inspect the air filter Inspect the indoor A/C coil if there is one present Dirty or missing Dirty Clean or replace Replaced Clean A/C coil as necessary Filter clean and supported properly? Remote filter/filter grille? No Indoor A/C coil clean? Filter clean and supported properly? Return ducts sealed all the way back to the furnace if a remote filter/filter grille is used? Indoor A/C coil clean? 3
4 Inspect, clean and adjust direct drive or belt drive blower assembly Dirty Clean and service Blower assembly serviced? N/A No blower Blower assembly serviced? N/A No blower All vented combustion appliances are to be tested under Worst Case Depressurization conditions in the combustion appliance zone (CAZ). More than one CAZ requires more than one CAZ depressurization test. Blower speed increased? No Set-Up Furnace and water heater off? Furnace filter clean or removed? Exterior windows and doors closed? Fireplace or wood stove dampers closed? Clothes dryer and all exhaust fans on? (Exception: Do not run whole house fans) Interior doors closed? (Exception: Do not close doors to rooms with exhaust fans only - no supply ducts) Blower door exhausting 300 CFM fireplace flow? N/A CAZ Depressurization Test Gauge set-up to measure CAZ WRT outside? Is there a door from the interior to the CAZ? No Forced air furnace? No CAZ door: Open Closed Furnace Fan OFF Pa Pa Furnace Fan ON Pa Pa Water Heater Test Procedure Initial *Note: The water heater is always tested first. Does the water heater have a properly installed pressure and temperature relief valve? No Water temperature/adjusted? No Fire the water heater Was initial flow established in the vent? No Was there spillage after two minutes? No Draft pressure after five minutes: WC or Pa Carbon monoxide after five minutes: / PPM Worst Case set-up complete? Worst Case Depressurization measurement of the CAZ Pa Water Heater: T&P relief valve? Temp: Adjusted? No Establish flow in vent? Spillage? No Draft pressure: Carbon monoxide: / PPM Worst Case set-up complete? Fan Off: Open Pa Closed Pa Fan On: Open Pa Closed Pa Final Worst Case Depressurization measurement of the CAZ Pa Water Heater: T&P relief valve? Temp: Adjusted? No Establish flow in vent? Spillage? No Draft pressure: Carbon monoxide: / PPM 4
5 Note: Initial combustion safety testing must be completed. If it is found that the appliances will not work under Worst Case conditions, then continue testing and repair under normal operating conditions and document for the Wx in the Follow-up section of this guide. Calibrate analyzer and insert probe in the vent connector upstream of the barometric damper. Monitor the oxygen reading on start-up! A change in 02 greater than 1% validates a bad heat exchanger. Furnace Combustion Testing Procedure Initial Fire the furnace Change in 02 when blower comes on: % Did the operation of the heating appliance cause spillage or a reduction in draft at any other appliance? No N/A Pump pressure: (optional) PSIG Adjusted to: PSIG Steady state 02: % Steady state Stack Temperature - Subtract Combustion air temperature - To get Net Stack Temperature: Steady state Combustion efficiency: % Burner type: Retention head Non-Retention head Breech draft: WC or Pa Overfire draft: WC or Pa Outside air temperature: Smoke: # Carbon Monoxide: PPM Temperature rise: Supply minus Return: Not tested under Worst Case Furnace Steady state: 02 % Stack temp: Combustion air temp: Net stack temp: Combustion efficiency % Breech draft: Overfire draft: Outside air temp: Smoke: # Carbon monoxide: PPM Temperature rise: Furnace Steady state: 02 % Stack temp: Combustion air temp: Net stack temp: Combustion efficiency % Breech draft: Overfire draft: Outside air temp: Smoke: # Carbon monoxide: PPM Temperature rise: /adjustments Bad heat exchanger Perform a high temperature limit switch test on the appropriate appliances Did not work Repair or replace High temperature limit switch operational? Limit temperature: High temperature limit switch operational? 5
6 Test flame out safety control CAD cell relay Stack switch Fail Replace switch or control Flame out safety switch operational? Flame out safety switch operational? Measure the fan off temperature. Re-set as close to 90 deg. as possible Not Adjust or replace switch Fan off temperature: Fan off temperature: Deg. F. Perform client education Client education completed? Verify client education completed? : Date: Final : Date: Agency reviewer: Date: Additional comments: Revision date: 5/5/03 6
7 7
8 8
Electric Heat Inspection Form Revised September 2012
Client name: Address: Primary Heat Source: Auxiliary Heat Application: Heat Pump Information: Equipment Information Electric Electric Heat Inspection Form Revised September 2012 Audit Existing furnace
More informationState of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety
5.3.1A(2) Page 1 of 2 State of ALASKA, Weatherization Assistance Program Technical Support Document Combustion Safety This document is intended to support in detail the Combustion Safety Test Report. The
More informationRetrofit Installer-Mechanical
Retrofit Installer-Mechanical Lesson Plan Section 1: Gas FurnaceFundamentals Learning Objectives By attending this session, participants will: Know the components of a gas furnace Understand the basic
More informationCOMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*
COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES* *Vented appliances refer to natural draft appliances equipped with a barometric draft regulator or Category I appliances equipped with a draft
More informationObjectives. Home Performance Diagnostics with the House of Pressure (Part 1) How can Pressure effect Building Performance?
Home Performance Diagnostics with the House of Pressure (Part 1) Objectives Learn the basic rules of air flow and differences Begin to be able to recognize building problems related to airflow and differences
More informationMBPA Home Performance FIELD DATA COLLECTION FORM
MBPA Home Performance FIELD DATA COLLECTION FORM Customer Information Test Date: Name Address City State Zip Phone: ( ) Email: Electric Provider Heating Fuel Provider Account Number Account Number Customer
More informationRESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO
RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com This session will address the basics of combustion and the latest
More informationSecond Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:
Second Revision No. 3-NFPA 31-2015 [ Section No. 10.5.1 ] 10.5.1* Oil burners, other than oil stoves with integral tanks, shall be provided with some means for manually stopping the flow of oil to the
More informationRESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO
RESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com Effective insulation and air sealing treatments can make a huge difference
More informationATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL
LINE ITEM # ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM DETAIL Labor Material FURNACE COMPONENTS 1 Furnish & Install Sight-Impaired Thermostat For Heating and Cooling
More informationEnergy Saver 101: Home Energy Audits
Energy Saver 101: Home Energy Audits Take the first step to improving your home s energy efficiency: get a home energy audit. What is a home energy audit? A home energy audit helps you pinpoint where your
More informationTASKS REGARDING COMBUSTION AIR
TASKS REGARDING COMBUSTION AIR DETERMINE IF THERE IS ENOUGH COMBUSTION AIR FOR THE TYPES OF APPLIANCES IN THE CAZ Use one of two methods, depending on appliance type and whether or not you have a blower
More informationEnergyMeasure HOME DATA COLLECTION FORM
EnergyMeasure HOME DATA COLLECTION FORM Section 1: General Information Customer Name: Site ID: Assessment Date: Street Address: City: State: Zip Code: Alternate Address: City: State: Zip Code: Telephone
More informationCOMBUSTION SAFETY BASICS
COMBUSTION SAFETY BASICS Joe Konopacki Why Combustion Safety? Hydrocarbon fuels are hazardous Explosion or fire is possible Poor indoor air quality Exhaust byproducts are harmful or deadly Safe and efficient
More informationELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b
PRODUCT SPECIFICATIONS OIL FURNACES El083b ELITE SERIES Lo-Boy Bulletin No. 20629 February 209 Supersedes July 202 MODEL NUMBER IDENTIFICATION el O 83 bf 0/4 p 60 AFUE - 83% Heating Input - 0,000 to 5,000
More informationCombustion Safety Testing: What we learn from Standards and Research. Objectives. Objectives 2/24/2016
Combustion Safety Testing: What we learn from Standards and Research Better Buildings Better Business Conference March 2016 Experience. Innovation. Results. Confiden al 2015 Objectives Identify differences
More informationCombustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO
Combustion Safety RESNET Conference San Antonio, TX February 27, 2006 Presented by Rich Moore Lightly Treading Energy & Design Denver, CO Goals of this session Recognize the need for combustion safety
More informationSERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA
SERVICE FACTS Gas Furnaces Upflow & Downflow Induced Draft Stage Heat Models: M80P00AU2AA M80P060AU2AA M80P060AU36AA M80P080BU36AA M80P080BU8AA M80P00BU36AA M80P00CU8AA M80P00CU60AA M80PDU60AA M80P0DU60AA
More informationPOWER VENTER. Model: PVE Series
POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power
More informationPVE SERIES POWER VENTER SYSTEM MANUAL
PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of
More informationAFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh
WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION
More informationBPI ANALYST ENVELOPE AUDIT FIELD EXAM CHECKLIST
BPI ANALYST ENVELOPE AUDIT FIELD EXAM CHECKLIST 1. Pre-Inspection Homeowner Interview (3 minutes) A. Turn on & zero CO Meters. Determine ambient CO : B. Record Outside Temperature: C. Homeowner interview:
More informationCombustion Appliance Safety Testing Guidelines
Combustion Appliance Safety Testing Guidelines This guide is intended to assist home performance contractors complete all combustion safety tests adequately and safely according to the Building Performance
More informationOIL-FIRED CENTRAL FURNACE
OIL-FIRED CENTRAL FURNACE Installation, Operation, and Service Manual With Users Information Section Models: CSHB60-90XE CSHB60-90XP c WARNING: Do NOT store or use gasoline or other flammable vapors and
More informationPLB350 Low Boy. Furnace Manual. Oil furnace KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. Hazard definitions
Oil furnace PLB350 Low Boy KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. Furnace Manual Contents Page Read this first!... 2 1. Prepare furnace location... 3 2. Prepare furnace and place in
More information(Information about THERMAL dampers for gas-fired appliances available on request.) WARNING
FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK 11788 U.S.A. TEL.: (516) 234-3600 FAX: (516) 234-3610 SPECIFICATIONS, INSTALLATION INSTRUCTIONS AND TROUBLE-SHOOTING GUIDE FOR STACK
More informationWhole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019
Whole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019 Note: This procedure is subject to revision or modification by PG&E at any
More informationFurnace Manual. Oil Furnaces PLB-112 LOW-BOY KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. Hazard definitions
Oil Furnaces PLB-112 LOW-BOY KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. C US Furnace Manual Contents Page Read this first!... 2 1. Installation... 3 2. Operation... 11 3. Maintenance...
More informationLeisure Line Power Vent Operations & Maintenance Manual And Safety Instructions
Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions Black Rock Manufacturing DBA Leisure Line Stove Company Rear 620 Broad Street Berwick, PA 18603 http://www.leisurelinestoves.com/ind
More informationAnticipating Depressurization Issues Due to Air Tightness and Ventilation Needs
Anticipating Depressurization Issues Due to Air Tightness and Ventilation Needs Rebecca Olson Neighborhood Energy Connection Duluth Energy Design Conference February 26 th, 2013 Duluth, MN Learning Objectives
More informationColumbia Boiler Company
EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net
More informationInternet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #
INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED
More informationPLB210 Low Boy. Oil furnace. Hazard definitions
Oil furnace PLB210 Low Boy KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. Furnace Manual Contents Page Read this first!... 2 Prepare furnace location... 3 Prepare furnace and place in position...
More informationDAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower
PRODUCT SPECIFICATIONS OIL FURNACES sl085bv DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower Bulletin No. 0677 August 05 Supersedes September 04 AFUE - Up to 87% Heating Input - 79,000 to
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationQHT Manual for: SU-2A Gas Burner
1 QHT Manual for: SU-2A Gas Burner 50,000 BTU/H to 250,000 BTU/H The burner shall be used only with NATURAL GAS or LP GAS. Warning: If the following instructions are not followed exactly, a fire or explosion
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FOR UPFLOW OIL FIRED FURNACES! Recognize this symbol as an indication of Important Safety Information!! WARNING If the information in these instructions is not followed exactly,
More informationHome Performance Science
Home Performance Science Symptoms of a Sick House Too hot/too cold rooms Respiratory problems Headaches/nausea Smoky fireplace Foggy windows Stuffy air and lingering odors Peeling paint Constant dust problems
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationINSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )
INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) FOR USE WITH MODEL: OH6FX072DV4 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationPOWER VENTER SYSTEM. Model: PVO-300, PVO-600
POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may
More informationBC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES
Models BC3095 BC4100 BC4115 BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES Maximum Allowable Working Pressure 30 psi. Manufactured by: ECR
More informationVF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual
342 N. Co. Rd. 400 East Valparaiso, IN 46383 888-432-8924 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. VF/VG700 Jumbo Construction
More informationOIL-FIRED CENTRAL FURNACE
OIL-FIRED CENTRAL FURNACE Installation, Operation, and Service Manual With Users Information Section Models: VHF-ABP VHF-ABT c WARNING: Do NOT store or use gasoline or other flammable vapors and liquids
More informationCertification Information
OIL HYDRONICS SERVICE CERTIFICATION Certification Information Scope - Tests a candidate's knowledge of the installation, service, maintenance, and repair of hot water heating systems. System sizes are
More informationFurnace Manual. Centennial Oil Furnaces CHB High Boy CLB Low Boy KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. Hazard definitions
Centennial Oil Furnaces CHB High Boy CLB Low Boy KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. C US Hazard definitions Furnace Manual Contents Page Read this first!... 2 1. Prepare furnace
More informationLeisure Line Power Vent Operations & Maintenance Manual And Safety Instructions
Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions Black Rock Manufacturing DBA Leisure Line Stove Company Rear 620 Broad Street Berwick, PA 18603 http://www.leisurelinestoves.com/ind
More informationCHIMNEY INSTALLATION. Technical Bulletin #1
Technical Bulletin #1 CHIMNEY INSTALLATION A chimney performs two functions: it removes smoke and flue gases from the stove/furnace, and it provides draft for the fire. Draft is the term used to describe
More informationIn accordance with the Department of Labor and Industry s statute , Subd. 11,
In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized by the Minnesota Department of Labor and Industry as satisfying 1.5 hours of
More informationINSTALLATION INSTRUCTIONS
2015 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS ELO183B SERIES UNITS Front Flue Model Shown RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT This unit must be serviced
More informationSnuggPro DATA COLLECTION FORM
SnuggPro DATA COLLECTION FORM Section 1: General Information Trade Ally: Trade Ally Telephone: Trade Ally Email: Auditor Name: Auditor Telephone: Auditor Email: Home Owner Name: Home Owner Telephone: Home
More informationOil Furnaces PMP-098 MULTI-POSITION. Hazard definitions
Oil Furnaces PMP-098 MULTI-POSITION KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. C US Furnace Manual Contents Page Read this first!... 2 1. Installation... 3 2. Operation... 12 3. Maintenance...
More informationRECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS
RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS 1 Contents Introduction... 3 Portfolio Energy Goals... 3 Purpose of This Document... 3 Gas Furnaces... 4 Electric Furnaces... 7
More informationBETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.
BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS. Value & Premier Oil Heating System Service Plans Choose the plan that s best for you and your home. WE PROMISE SERVICE PLANS THAT
More informationOil Furnaces PMP-112 MULTI-POSITION. Hazard definitions
Oil Furnaces PMP-112 MULTI-POSITION KEEP THESE INSTRUCTIONS WITH FURNACE FOR FUTURE REFERENCE. C US Furnace Manual Contents Page Read this first!... 2 1. Installation... 3 2. Operation... 12 3. Maintenance...
More information80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.
FURNACES The Ameristar line of heating and cooling products offer you flexible and affordable options for HVAC equipment replacement. The Ameristar product line should complement the national brand you
More informationLATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners
1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):
More informationGas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)
Gas Safety Syllabus For Gas Appliance Service Certificate of Qualification Examination (Formerly Class C) 1. Prerequisites to obtain a gas appliance service certificate of qualification An applicant for
More informationA. Section Common Motor Requirements for HVAC Equipment: Fan motors.
SECTION 235533 - FUEL-FIRED UNIT HEATERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gas fired unit heaters. B. Oil fired unit heaters. C. Tubular infrared heaters. 1.2 RELATED REQUIREMENTS A. Section 230513
More informationINSTALLATION INSTRUCTIONS
2012 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS ELO183B SERIES UNITS Front Flue Model Shown RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT This unit must be serviced
More informationMontana Weatherization Program WEATHERIZATION FINAL INSPECTION REPORT (Mobile Homes) Client Name Address Contact phone # Inspector Name and QCI#
EA #. Date Priority # HEALTH & SAFETY Hazardous Material Assessment Electrical Repairs Performed by Licensed Professional Solid Fuel Burning Appliance CO Detection/Warning, Occupant Education, # Installed.
More informationDOMESTIC WATER HEATER OIL FIRED
DOMESTIC WATER HEATER OIL FIRED Models : CMO32-II CMO32-II-R CMO50-II CMO32-II & CMO32-II-R INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE
More informationAFG AFG. Instruction Manual MODEL. Oil Burner. Types F & M air tubes Motor voltage: 120 Vac / 60 Hz. AFG burner with type F air tube
MODEL AFG Oil Burner Instruction Manual AFG Types F & M air tubes Motor voltage: 120 Vac / 60 Hz AFG burner with type F air tube Type L1 head Type V1 head Type M air tube combinations Contents Prepare
More informationSA Series Start up Report
SA Series Start up Report Important To ensure warranty validation and continued customer satisfaction, complete this form and return it to Desert Aire immediately after start-up. Validation of this report
More informationSpray Polyurethane Foam and Open-Combustion Appliances
Spray Polyurethane Foam and Open-Combustion Appliances Before applying SPF (spray foam polyurethane) insulation in an attic or crawl space it is important to determine if there are any appliances present,
More informationInstallation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing
Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed
More informationBUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS
BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS FOR THE BUILDING ANALYST PROFESSIONAL Health and Safety All technicians performing diagnostic tests, inspections, or installations, must have access to
More informationFEATURES AND BENEFITS
FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory
More informationInstallation, Operation and Service Manual
Installation, Operation and Service Manual KLF-100 85% + EFFICIENCY OIL FIRED LOWBOY FURNACE INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual
More informationWAP Pressure Diagnostics Procedure. Page 1
WAP Pressure Diagnostics Procedure Page 1 This document is meant to describe an overall procedure that will allow a WAP Energy Assessor to conduct a thorough blower door / manometer guided diagnostic assessment
More informationCMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50
DOMESTIC WATER HEATER OIL-FIRED Models: CMO32 CMO50 DNS-1102 Rev. A DNS-0413 Rev. A CMO32 CMO50 INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF
More informationIllinois Home Weatherization Assistance Program - Field Standards Manual
Illinois Home Weatherization Assistance Program - Field Standards Manual Contents 100 Diagnostic Standards 111 Blower Door 1111 House Set-Up 11111 Basements 1112 Blower Door Test 11121 Building Tightness
More informationBryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired
Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20
More informationGENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.
GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO. GBI 201-5 3C For a proper installation and in order to receive the best in operating life and efficiency from your
More informationCombustion Sources of Carbon Monoxide. Carbon Monoxide Repairs. Topics Addressed in Session. Why CO can be Harmful Inhalation Time and Symptoms
Affordable Comfort Conference 2002 Saturday, April 20, 8:00 12:00 Rick Karg R.J. Karg Associates www.karg.com April 2002 2002 R.J. Karg Associates Topics Addressed in Session Combustion sources of CO.
More informationDirect Vent System Required
CB-200A Cottage Base Installation Instructions IMPORTANT: Read all instructions carefully before beginning the installation. This base must be installed by a qualified installing agency and in accordance
More informationEnergy Design Conference 2016 Test Protocols & Results: Airport Sound Program and Building America Field Tests
Energy Design Conference 2016 Test Protocols & Results: Airport Sound Program and Building America Field Tests Dave Bohac, PE Center for Energy and Environment MSP Airport Sound Program Weatherization
More informationSERIES 19A. mith PRESSURIZED WET BASE
SERIES 19A mith series19a BOILER/BURNER PRESSURIZED WET BASE UNIT series 19A STANDARD EQUIPMENT All s Cast iron wet-base sections tested for 80psi. Insulated metal jacket Cast iron smokehood with integral
More informationOIL-FIRED CENTRAL FURNACE
OIL-FIRED CENTRAL FURNACE Installation, Operation, And Service Manual With Users Information Section Models: TDF1M087C942SA TLF1M087C942SA TLR1M087C942SA TDF1M087D9V5SA TLF1M087D9V5SA TLR1M087D9V5SA c
More informationOHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120
P R O D U C T S P E C I F I C AT I O N S O I L F U R N A C E S OHR23 ELITE SERIES Horizontal/Downflow ulletin No. 20097 February 20 Supersedes October 200 AFUE - Up to 83.5% Input - 05,000 to 54,000 tuh
More informationBurner Comparisons. Typical Competitor s Burner
Burner Comparisons INOV8 s Typical Competitor s Burner Automatic nozzle cleanout Yes No Available BTUs rated as input 100,000 to 1,000,000 76,500 to 500,000 Burner Motor - hp 1/5 1/7 Combustion safety
More informationNew Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011
New Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011 Customer: Street: City: Zip: Phone: (Home): ( ) - Phone: (Work): ( ) - Owner: Yes No/ Name: Phone: ( )
More informationIndirect gas-fired air heater
Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury
More informationINSTALLATION INSTRUCTIONS
2011 Lennox Industries Inc. Dallas, Texas, USA Front Flue Model RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury
More informationFEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).
This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency
More informationOverview of Gas Range Types
Residential Gas Ranges Overview of Types How Carbon Monoxide is Emitted How They Operate Overview of Gas Range Types Rick Karg R.J. Karg Associates www.karg.com November 2001 2001 R.J. Karg Associates
More informationForced draught natural gas/propane burner
Installation, use and maintenance instructions GB Forced draught natural gas/propane burner Single stage operation CODE MODEL 20096942 G400 (2) - 11/2015 Original instructions TABLE OF CONTENTS Installation
More informationM3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially
More informationExperienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning
Blueprint HVAC - Heating, Ventilation and Air Conditioning Test Code: 0144 / Version: 02 Specific Competencies and Skills Tested in this Assessment: Electricity Demonstrate understanding of basic AC/DC
More informationSunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve
HVAC Maintenance Checklist Template conducted for Sunny Hills Conducted on 31 Oct 2018 03:40 PM Prepared by Jon Nieve Location 102 S Mendel St, Fort Stockton, TX 79735, USA Completed on 31 Oct 2018 04:11
More informationSingle stage operation forced draught natural gas/propane burner
Installation & Operating Manual Single stage operation forced draught natural gas/propane burner The following pages contain information, descriptions and diagrams for the proper installation and wiring
More informationE3EH-xxx-H Series E3EB-xxx-H Series
TECHNICAL SPECIFICATIONS E3EH-xxx-H Series E3EB-xxx-H Series Downflow, Upflow Electric Furnaces The E3 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate
More informationHeating system service plans that provide total peace of mind.
Heating system service plans that provide total peace of mind. Value & Premier Oil Heating System Service Plans Choose the plan that s best for you and your home. The service plans you need to keep your
More informationE2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits
TECHNICAL SPECIFICATIONS E2 Series Downflow, Upflow Electric Furnaces The E2 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low maintenance.
More informationIntroductions HERS Industry HERS Ratings ACCA Standard 12 Resources
Abe Kruger 2013 RESNET Conference abe@krugersustainabilitygroup.com 215/385-6891 Introductions HERS Industry HERS Ratings ACCA Standard 12 Resources www.krugersustainabilitygroup.com 1 HERS Rater & Trainer/QAD
More informationTECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES
036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING
More informationOIL-FIRED CENTRAL FURNACE
OIL-FIRED CENTRAL FURNACE Installation, Operation, and Service Manual With Users Information Section Models: THV1C072A948SA THV1C072A9V4SA c WARNING: Do NOT store or use gasoline or other flammable vapors
More informationWARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN
600 OLD WILLETS PATH HAUPPAUGE, NEW YORK 11788 U.S.A. TEL.: (516) 234-3600 FAX: (516) 234-3610 SPECIFICATIONS, INSTALLATION INSTRUCTIONS AND TROUBLE-SHOOTING GUIDE FOR STACK PACK MOTORIZED VENT DAMPER
More informationProduct Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY
MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH Product Data THE LATEST IN OIL FURNACE TECHNOLOGY A10311 The models OBM and OVM combine high efficiency and quiet operation with oil heating
More information