INITIAL START-UP CHECKLIST FOR 23XL HERMETIC SCREW LIQUID CHILLER

Size: px
Start display at page:

Download "INITIAL START-UP CHECKLIST FOR 23XL HERMETIC SCREW LIQUID CHILLER"

Transcription

1 INITIAL START-UP CHECKLIST FOR 23XL HERMETIC SCREW LIQUID CHILLER (Remove and use for job file.) MACHINE INFORMATION: NAME ADDRESS JOB NO. MODEL CITY STATE ZIP S/N DESIGN CONDITIONS: TONS BRINE FLOW RATE TEMPERATURE IN TEMPERATURE OUT PRESSURE DROP PASS SUCTION TEMPERATURE CONDENSER TEMPERATURE COOLER ****** CONDENSER ****** COMPRESSOR: Volts RLA OLTA S/N STARTER: Mfg Type S/N REFRIGERANT: Type: Charge Lbs (Kg) CARRIER OBLIGATIONS: Assemble...Yes No Leak Test...Yes No Dehydrate...Yes No Charging...Yes No Operating Instructions Hrs. START-UP TO BE PERFORMED IN ACCORDANCE WITH APPROPRIATE MACHINE START-UP INSTRUCTIONS JOB DATA REQUIRED: 1. Machine Installation Instructions...Yes No 2. Machine Assembly, Wiring, and Piping Diagrams...Yes No 3. Starting Equipment Details and Wiring Diagrams...Yes No 4. Applicable Design Data (see above)...yes No 5. Diagrams and Instructions for Special Controls...Yes No INITIAL MACHINE PRESSURE: Was Machine Tight? If Not, Were Leaks Corrected? Was Machine Dehydrated After Repairs? YES NO CHECK OIL LEVEL AND RECORD: SIGHT GLASS LOCATION OIL SUMP SEPARATOR ADD OIL: Yes No Amount: RECORD PRESSURE DROPS: Cooler Condenser CHARGE REFRIGERANT: Initial Charge Final Charge After Trim Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 PC 211 Catalog No Printed in U.S.A. Form 23XL-2SS Pg CL Replaces: 23XL-1SS Tab 5e

2 INSPECT WIRING AND RECORD ELECTRICAL DATA: RATINGS: Motor Voltage Motor(s) Amps Starter Amps Line Voltages: Motor Controls/Oil Heater FIELD-INSTALLED STARTERS ONLY: Check continuity T1 to L1, etc. (Motor to starter, disconnect motor leads T4, T5, T6.) Do not megger solid-state starters, disconnect leads to motor and megger the leads. MEGGER MOTOR 1-Second Readings: 6-Second Readings: Polarization Ratio: PHASE TO PHASE PHASE TO GROUND T1-T2 T1-T3 T2-T3 T1-G T2-G T3-G STARTER: Electro-Mechanical Solid-State Motor Load Current Transformer Ratio : Signal Resistor Size Ohms Transition Timer Time Seconds Check Magnetic Overloads Add Dash Pot Oil Yes No Solid-State Overloads Yes No Solid State Starter: Torque Setting O Clock Ramp Setting Seconds CONTROLS: SAFETY, OPERATING, ETC. Perform Control Test (Yes/No) PIC CAUTION COMPRESSOR MOTOR AND CONTROL CENTER MUST BE PROPERLY AND INDIVIDUALLY CONNECTED BACK TO THE EARTH GROUND IN STARTER. (IN ACCORDANCE WITH CERTIFIED DRAWINGS). Yes RUN MACHINE: Do these safeties shut down machine? Condenser Water Flow Switch Yes No Chilled Water Flow Switch Yes No Pump Interlocks Yes No INITIAL START: Line Up All Valves in Accordance With Instruction Manual: Start Water Pumps and Establish Water Flow Oil Level OK and Oil Temperature OK Check Oil Pressure Check Compressor Motor Rotation (See Status Messages On the LID Default Screen) and Record: Correct Incorrect Restart Compressor, Bring Up To Speed. Shut Down. Any Abnormal Coastdown Noise? Yes* No *If yes determine cause. START MACHINE AND OPERATE. COMPLETE THE FOLLOWING: A: Trim Charge as Shown Under Charge Refrigerant Into Machine Section on pages 55 and 56. Record Charge. B: Complete Any Remaining Control Calibration and Record Under Controls Section (pages 13-37). C: Take At Least 2 Sets of Operational Log Readings and Record. E: After Machine Has Been Successfully Run and Set Up, Shut Down and Mark Shutdown Oil and Refrigerant Levels. F: Give Operating Instructions to Owner s Operating Personnel. Hours Given: Hours G. Call your local Carrier factory representative to report start up. SIGNATURES: CARRIER TECHNICIAN DATE CUSTOMER REPRESENTATIVE DATE CL-2

3 23XL HERMETIC SCREW LIQUID CHILLER CONFIGURATION SETTINGS LOG (Remove and use for job file.) 23XL SET POINT TABLE CONFIGURATION SHEET DESCRIPTION UNITS RANGE DEFAULT VALUE Base Demand Limit % 4 to 1 1 LCW Setpoint ECW Setpoint ICE Build Setpoint 15 to 12 ( 9.44 to 48.9) 2 to 12 ( 6.7 to 48.9) 2 to 6 ( 6.7 to 15.6) 5. (1) 6. (15.6) 4 (4.4) PSIO Software LID Software Version Version PSIO Controller Identification: Bus Address LID Identification: Bus Address CL-3

4 LOCAL 23XL PIC TIME SCHEDULE CONFIGURATION SHEET OCCPC1S Day Flag Occupied Unoccupied M T W T F S S H Time Time Period 1: Period 2: Period 3: Period 4: Period 5: Period 6: Period 7: Period 8: NOTE: Default setting is OCCUPIED 24 hours each day. ICE BUILD 23XL PIC TIME SCHEDULE CONFIGURATION SHEET OCCPC2S Day Flag Occupied Unoccupied M T W T F S S H Time Time Period 1: Period 2: Period 3: Period 4: Period 5: Period 6: Period 7: Period 8: NOTES: 1. Default setting is OCCUPIED 24 hours each day. 2. Only applicable to 23XL machines with PSIO software version 13 and higher. Period 1: Period 2: Period 3: Period 4: Period 5: Period 6: Period 7: Period 8: NOTE: Default setting is OCCUPIED 24 hours each day. CCN 23XL PIC TIME SCHEDULE CONFIGURATION SHEET OCCPC S Day Flag Occupied Unoccupied M T W T F S S H Time Time CL-4

5 23XL PIC CONFIG TABLE CONFIGURATION SHEET RESET TYPE 1 Degrees Reset at 2 ma RESET TYPE 2 Remote Temp (No Reset) Remote Temp (Full Reset) Degrees Reset RESET TYPE 3 CHW Temp (No Reset) CHW Temp (Full Reset) Degrees Reset 3 to 3 ( 17 to 17) 4 to ( 4 to 118) 4 to ( 4 to 118) 3 to 3 ( 17 to 17) to15 ( to 8) to15 ( to 8) 3 to 3 ( 17 to 17) (DEC C) 1 (6) 85 (29) 65 (18) Select/Enable Reset Type to3 ECW Control Option Disable/Enable Disable Demand Limit at 2 ma 4 to 1 % 4 2 ma Demand Limit Option Disable/Enable Disable Auto Restart Option Disable/Enable Disable Remote Contacts Option Disable/Enable Disable Temp Pulldown Deg/Min 2to1 3 Load Pulldown %/Min 5to2 1 Select Ramp Type: Temp=/Load=1 /1 1 Loadshed Group Number to99 Loadshed Demand Delta to6 % 2 Maximum Loadshed Time to 12 Min 6 CCN Occupancy Config: Schedule Number 3to99 3 CCN Occupancy Config: Broadcast Option Disable/Enable Disable ICE BUILD Option Disable/Enable Disable ICE BUILD TERMINATION: = TEMP, 1 = CONTACTS,,1,2 2 = BOTH ICE BUILD RECYCLE Option Disable/Enable Disable 1 (6) 1 (6) () 5 (3) CL-5

6 23XL PIC SERVICE1 TABLE CONFIGURATION SHEET Motor Temp Override Cond Pressure Override Refrig Override Delta T 15 to 2 (66 to 93) 15 to 25 (134 to 1724) 2to5 (1 to 3) psi (kpa) 2 (93) 23 (1586) Chilled Medium Water/Brine Water Brine Refrig Trippoint Compr Discharge Alert 8to4 ( 13 to 4) 17 to 2 (52 to 93) Water Flow Verify Time.5 to 5 MIN 5 Oil Filter Press Alert Water/Brine Deadband Recycle Restart Delta T 15 to 3 (14 to 27).5 to 2. (.3 to 1.1) 2. to 1. (1.1 to 2.8) psi (kpa) Hot Gas Bypass Option /1 HGBP Delta T1 HGBP Delta P1 HGBP Delta T2 HGBP Delta P2 HGBP Deadband.5 to 15. (.3 to 5.6) 5 to 2 (345 to 1172) [3 to 17 (26 to 1172)].5 to 15. (.3 to 5.6) 5 to 2 (345 to 1172) [3 to17 (26 to 1172)] 1to3 (.6 to 1.6) psi (kpa) psi (kpa) 3 (1) 33 (1) 2 (93) 3 (27) 1. (.6) 5 (2.8) 2.5 (1) 5 (345) [3 (27)] 1 (5.6) 2 (1379) [17 (1172)] Demand Limit Source Amps=/Load=1 /1 Amps Correction Factor 1to8 3* 1 (.6) *Default value should not be changed. NOTE: Values in [ ] indicate HFC-134a values, if this refrigerant is configured in the CONTROL TEST. CL-6

7 23XL PIC SERVICE1 TABLE CONFIGURATION SHEET Motor Rated Load Amps 1 to 9999 AMPS 2 Motor Rated Line Voltage 1 to 9999 VOLTS 46 Motor Rated Line kw 1 to 9999 kw 6 Line Frequency Select: =6 Hz, 1=5 Hz /1 Hz Compressor Starter Type /1 REDUCE/FULL Variable Inlet Enable /1 DISABLE/ENABLE Economizer Installed? /1 NO/YES Condenser Freeze Point 2 to 35 ( 28.9 to 1.7) 34 (1.1) Soft Stop Amps Threshold 4 to 1 % 1 23XL PIC LEAD/LAG TABLE CONFIGURATION SHEET LEAD/LAG SELECT DISABLE=, LEAD=1, LAG=2, STANDBY=3 to3 Load Balance Option DSABLE/ENABLE DSABLE Common Sensor Option DSABLE/ENABLE LAG Percent Capacity 25 to 75 % 5 LAG Address 1 to LAG START Timer 2 to 6 MIN 1 LAG STOP Timer 2 to 6 MIN 1 PRESTART FAULT Timer 2to3 MIN 5 STANDBY Chiller Option DSABLE/ENABLE DSABLE STANDBY Percent Capacity 25 to 75 % 5 STANDBY Address 1 to CL-7

8 23XL PIC SERVICE2 TABLE CONFIGURATION SHEET RESET 2 ma Power Source /1 DEMAND 2 ma Power Source /1 CHWS Temp Enable CHWS Temp Alert CHWR Temp Enable CHWR Temp Alert Reset Temp Enable Reset Temp Alert Spare Temp 1 Enable Spare Temp 1 Alert Spare Temp 2 Enable Spare Temp 2 Alert Spare Temp 3 Enable Spare Temp 3 Alert to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) SPARE 1 2 ma Power Source /1 SPARE 2 2 ma Power Source /1 Spare Temp 4 Enable Spare Temp 4 Alert Spare Temp 5 Enable Spare Temp 5 Alert Spare Temp 6 Enable Spare Temp 6 Alert Spare Temp 7 Enable Spare Temp 7 Alert Spare Temp 8 Enable Spare Temp 8 Alert Spare Temp 9 Enable Spare Temp 9 Alert to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) to2 4 to ( 4 to 118) =EXTERNAL 1=INTERNAL =EXTERNAL 1=INTERNAL =DISABLE =DISABLE =DISABLE =DISABLE =DISABLE =DISABLE =EXTERNAL 1=INTERNAL =EXTERNAL 1=INTERNAL =DISABLE =DISABLE =DISABLE =DISABLE =DISABLE =DISABLE CL-8

9 23XL PIC SERVICE3 TABLE CONFIGURATION SHEET Proportional Inc Band 5to1 6.5 Proportional Dec Band 5to1 6. Proportional ECW Gain 1to3 2. HOLIDAY (HOLIDEF) CONFIGURATION SHEET HOLIDEF S DESCRIPTION RANGE UNITS VALUE Holiday Start Month Start Day 1to12 1to31 Duration to99 DAYS HOLIDAY (HOLIDEF) CONFIGURATION SHEET HOLIDEF S DESCRIPTION RANGE UNITS VALUE Holiday Start Month Start Day 1to12 1to31 Duration to99 DAYS HOLIDAY (HOLIDEF) CONFIGURATION SHEET HOLIDEF S DESCRIPTION RANGE UNITS VALUE Holiday Start Month Start Day 1to12 1to31 Duration to99 DAYS NOTE: There are no HOLIDAYS defined on the default menu. HOLIDAY dates must be updated yearly if they are used. CL-9

10 BROADCAST (BRODEFS) CONFIGURATION SHEET Activate Yes/No No OAT Broadcast Controller Name 8 characters Text Bus Number to 239 Bus #s Element Number to 239 SE #s OARH Broadcast Controller Name 8 characters Text Bus Number to 239 Bus #s Element Number to 239 SE #s Daylight Savings Start Month 1to12 4 Day 1to31 15 Time : to 23:59 HH:MM 2: Minutes To Add 1 to 144 MIN 6 Daylight Savings Stop Month 1to12 1 Day 1to31 15 Time : to 23:59 HH:MM 2: Minutes To Subtract 1 to 144 MIN 6 CL-1

11

12 Copyright 1994 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 PC 211 Catalog No Printed in U.S.A. Form 23XL-2SS Pg CL Replaces: 23XL-1SS Tab 5e

INITIAL START-UP CHECKLIST FOR 19XR HERMETIC CENTRIFUGAL LIQUID CHILLER

INITIAL START-UP CHECKLIST FOR 19XR HERMETIC CENTRIFUGAL LIQUID CHILLER INITIAL START-UP CHECKLIST FOR 19XR HERMETIC CENTRIFUGAL LIQUID CHILLER (Remove and use for job file.) MACHINE INFORMATION: NAME JOB NO. ADDRESS MODEL CITY STATE ZIP S/N DESIGN CONDITIONS: TONS BRINE FLOW

More information

Start-Up, Operation, and Maintenance Instructions

Start-Up, Operation, and Maintenance Instructions 17/19EX 50/60 Hz Centrifugal Liquid Chillers with HFC-134a Start-Up, Operation, and Maintenance Instructions Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

Start-Up, Operation, and Maintenance Instructions

Start-Up, Operation, and Maintenance Instructions Start-Up, Operation, and Maintenance Instructions SAFETY CONSIDERATIONS 17/19EX Centrifugal Liquid Chillers 50/60 Hz With HFC-134a Centrifugal liquid chillers are designed to provide safe and reliable

More information

MicroTech Series-200 Flooded Screw Chiller

MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Infomation Packet Version 1.0 Group: Controls Date: February 1997 MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Communications 2002 McQuay International - C O N F I D

More information

MicroTech Series 200 Centrifugal Chiller

MicroTech Series 200 Centrifugal Chiller Protocol Data Information Packet Version 2.2 Group: Controls Date: March 1999 MicroTech Series 200 Centrifugal Chiller Data Communications Packet for Protocol 2002 McQuay International Revision History

More information

Open Protocol Data Communications

Open Protocol Data Communications MicroTech Series-100 Centrifugal Chiller Open Protocol Data Communications Information Packet Version 3.2 April, 1996 - C O N F I D E N T I A L - This Document may not be copied or reproduced in any way

More information

Installation, Start-Up, and Operating Instructions

Installation, Start-Up, and Operating Instructions Installation, Start-Up, and Operating Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 GENERAL...1 INSTALLATION...1-5 Install Batteries...1 Select Transmitter Location (Optional)...1 Mount Transmitter

More information

CONTROLS MANUAL. Touch Pilot Control. 30XA/XAS/XW 30XA-ZE/XW-ZE AquaForce PUREtec with R-1234ze(E) Operation instructions.

CONTROLS MANUAL. Touch Pilot Control. 30XA/XAS/XW 30XA-ZE/XW-ZE AquaForce PUREtec with R-1234ze(E) Operation instructions. CONTROLS MANUAL Touch Pilot Control 30XA/XAS/XW 30XA-ZE/XW-ZE AquaForce PUREtec with R-1234ze(E) Operation instructions Original document CONTENTS 1 -.SAFETY CONSIDERATIONS... 5 1.1 -.General description...

More information

McQuay BACnet Solution: Microtech II Water-Cooled Centrifugal Chiller Controller (WSC, WDC, WPV)

McQuay BACnet Solution: Microtech II Water-Cooled Centrifugal Chiller Controller (WSC, WDC, WPV) Point Map December 1, 2004 Systems Integration McQuay BACnet Solution: Microtech II Water-Cooled Centrifugal Chiller Controller (WSC, WDC, WPV) Table 1. Microtech II Water-Cooled Centrifugal Chiller Controller

More information

CONTROLS MANUAL. Touch Pilot Control. 30XA/XAS/XB/XBP/XW 30XA-ZE/XW-ZE AquaForce PUREtec with R-1234ze(E) Operation instructions.

CONTROLS MANUAL. Touch Pilot Control. 30XA/XAS/XB/XBP/XW 30XA-ZE/XW-ZE AquaForce PUREtec with R-1234ze(E) Operation instructions. CONTROLS MANUAL Touch Pilot Control 30XA/XAS/XB/XBP/XW 30XA-ZE/XW-ZE AquaForce PUREtec with R-1234ze(E) Operation instructions Original document CONTENTS 1 -.SAFETY CONSIDERATIONS... 5 1.1 - General description...

More information

Touch Pilot Control 30XA/XAS/XB/XBP/XW 30XA-ZE/XW-ZE. AquaForce PUREtec with R-1234ze(E) Original document

Touch Pilot Control 30XA/XAS/XB/XBP/XW 30XA-ZE/XW-ZE. AquaForce PUREtec with R-1234ze(E) Original document C O N T R O L S M A N U A L Touch Pilot Control 30XA/XAS/XB/XBP/XW 30XA-ZE/XW-ZE AquaForce PUREtec with R-1234ze(E) Original document CONTENTS 1 - SAFETY CONSIDERATIONS...5 1.1 - General description...5

More information

30XW-V/30XWHV. Touch Pilot Control. Operation and maintenance instructions. Original document

30XW-V/30XWHV. Touch Pilot Control. Operation and maintenance instructions. Original document 30XW-V/30XWHV Touch Pilot Control Operation and maintenance instructions Original document Contents 1 - SAFETY CONSIDERATIONS...4 1.1 - General... 4 1.2 - Avoid electrocution...4 2 - GENERAL DESCRIPTION...4

More information

Reciprocating Chiller

Reciprocating Chiller HVAC PRO for Windows User s Manual 637.5 OEM Section Technical Bulletin Issue Date 1094 Reciprocating Chiller Reciprocating Chiller Page 3 Description 3 Theory of Operation 5 Overview 5 Control Sequence

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO: Supersedes: (316) Form QTC4-CL2 (617) MODEL QTC4 EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: ADDRESS: PHONE: JOB NAME: LOCATION: CUSTOMER ORDER NO: TEL NO: ORDER NO: CONTRACT NO: CHILLER MODEL

More information

YST PRE START-UP CHECKLIST

YST PRE START-UP CHECKLIST STEAM TURBINE CENTRIFUGAL LIQUID CHILLERS START-UP CHECKLIST Supersedes 160.67-CL1 (1108) Form 160.67-CL1 (114) YST PRE START-UP CHECKLIST OFFICE LOCATION TECHNICIAN S NAME UNIT MODEL NUMBER YORK CONTRACT

More information

Start-Up, Operation, and Maintenance Instructions

Start-Up, Operation, and Maintenance Instructions Start-Up, Operation, and Maintenance Instructions Centrifugal liquid chillers are designed to provide safe and reliable service when operated within design specifications. When operating this equipment,

More information

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME: Supersedes: 201.28-CL2 (817) Form 201.28-CL2 (1017) MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: PHONE: JOB NAME: CUSTOMER ORDER NO: JCI CONTRACT NO: CHILLER MODEL

More information

Wiring Diagrams DIAGRAM INDEX 208/230PW,XL;380PW;380/415PW;460PW;575PW XL;380/415XL;460XL;575XL ,070

Wiring Diagrams DIAGRAM INDEX 208/230PW,XL;380PW;380/415PW;460PW;575PW XL;380/415XL;460XL;575XL ,070 30GTN,GTR040-420 30GUN,GUR040-420 ComfortLink Reciprocating Liquid Chillers 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GTN,GTR,GUN,GUR Voltage Figure Label Diagram Number No. 30GT-

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

FieldServer Driver - Serial FS McQuay Microtech Open Protocol Description FieldServer Driver - Serial FS-8700-80 McQuay Microtech Open Protocol This is an active client protocol. The driver is capable of acting as a master or slave. As a master, the Fieldserver polls

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

YCIV Hz & Hz

YCIV Hz & Hz YCIV 0590-1500 50Hz & 0157-0397 60Hz Start-up Checklist SERVICE POLICY & PROCEDURES Supersedes: Nothing Form 201.23-CL1 (309) Commissioning PREPARATION Commissioning of this unit should only be carried

More information

Installation Instructions

Installation Instructions Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL Cooling Only, Heat Cool, and Heat Pump B. Assemble tools: o AUTO COOL HEAT o MULTI-STAGE SEVEN DAY PROGRAMMABLE Table of Contents STEP #1 PREPARATION

More information

Advanced Centrifugal Engineering

Advanced Centrifugal Engineering Product Data 19XT Hermetic Centrifugal Liquid Chiller 50/60 Hz HFC-134a 300 to 550 Nominal Tons (1055 to 1934 kw) Advanced Centrifugal Engineering Reduced operating costs are achieved through an improvement

More information

Installation, Service, and Troubleshooting Instructions

Installation, Service, and Troubleshooting Instructions 33CS TEMP System Unitary Controller Thermostat Installation, Service, and Troubleshooting Instructions Page GENERAL........................................ 2 TEMP System Components......................

More information

Ice Rink (Single and Dual Configurations) Custom Control Features

Ice Rink (Single and Dual Configurations) Custom Control Features & M&M Refrigeration, Inc. Computer Control System Ice Rink (Single and Dual Configurations) Custom Control Features REVISION DATE DESCRIPTION - 4/20/05 Original release. A 09/21/98 Update Chiller Pump

More information

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON Owner s Manual Part Number 33CSSP2-FC 33CS Fan Coil Programmable Thermostat SAFETY CONSIDERATIONS Read and follow manufacturer instructions carefully. Follow all local electrical codes during installation.

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

GeneSys Air-Cooled Screw Compressor Chiller

GeneSys Air-Cooled Screw Compressor Chiller Operation Manual OM AGSB-5 Group: Chiller Part Number: 331373201 Date: June 2005 Supersedes: OM AGSB-4 GeneSys Air-Cooled Screw Compressor Chiller AGS 230A/B through AGS 475A/B, 60 Hertz AGS 206A/B through

More information

Start-Up, Operation and Maintenance Instructions

Start-Up, Operation and Maintenance Instructions Start-Up, Operation and Maintenance Instructions Screw liquid chillers are designed to provide safe and reliable service when operated within design specifications. When operating this equipment, use good

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Owner s Manual. Part Number 33CSCPACHP-01

Owner s Manual. Part Number 33CSCPACHP-01 Comfort Pro Programmable Commercial Thermostat Owner s Manual Part Number 33CSCPACHP-01 SAFETY CONSIDERATIONS Read and follow manufacturer instructions carefully. Follow all local electrical codes during

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

MicroTech Water-Cooled Screw Chiller Controller

MicroTech Water-Cooled Screw Chiller Controller BACnet Data Information Packet BD 02-8 Group: Controls Date: January 2003 MicroTech Water-Cooled Screw Chiller Controller Point mapping data for the MicroTech BACdrop Gateway with PMF version 1.10 software

More information

19XR PIC II/19XRV PIC III. Hermetic Centrifugal Liquid Chillers. Nominal cooling capacity kw. 50 Hz

19XR PIC II/19XRV PIC III. Hermetic Centrifugal Liquid Chillers. Nominal cooling capacity kw. 50 Hz 19XR PIC II/19XRV PIC III Hermetic Centrifugal Liquid Chillers Nominal cooling capacity 1000-5300 kw 50 Hz Installation, operation and maintenance instructions Contents INITIAL START-UP CHECKLIST FOR 19XR

More information

Product Data. Features/Benefits. 19EX Centrifugal Liquid Chiller to 2200 Nominal Tons (5280 to 7740 kw)

Product Data. Features/Benefits. 19EX Centrifugal Liquid Chiller to 2200 Nominal Tons (5280 to 7740 kw) Product Data 19E Centrifugal Liquid Chiller 1500 to 2200 Nominal Tons (5280 to 7740 kw) Carrier s 19E Hermetic 19E Centrifugal Liquid Chillers operate with environmentally safe HFC-134a. These chillers

More information

Start-Up, Operation, and Maintenance Instructions

Start-Up, Operation, and Maintenance Instructions Start-Up, Operation, and Maintenance Instructions Centrifugal liquid chillers are designed to provide safe and reliable service when operated within design specifications. When operating this equipment,

More information

MicroTech Self-Contained Air Conditioning System

MicroTech Self-Contained Air Conditioning System Open Protocol Data Information Packet Version 2.3 Group: Controls Date: October 1999 MicroTech Self-Contained Air Conditioning System Open Protocol Data Communications t 2002 McQuay International - C O

More information

19XR PIC II/19XRV PIC III. Hermetic Centrifugal Liquid Chillers. Nominal cooling capacity kw. 50 Hz

19XR PIC II/19XRV PIC III. Hermetic Centrifugal Liquid Chillers. Nominal cooling capacity kw. 50 Hz 19XR PIC II/19XRV PIC III Hermetic Centrifugal Liquid Chillers Nominal cooling capacity 1000-5300 kw 50 Hz Installation, operation and maintenance instructions Contents INITIAL START-UP CHECKLIST FOR 19XR

More information

Owner s Manual. Part Number 33CS250-01

Owner s Manual. Part Number 33CS250-01 33CS Commercial Programmable Thermostat IMPORTANT: Read entire instructions before programming the thermostat. Owner s Manual Part Number 33CS250-01 GENERAL Carrier s 7-day, commercial, programmable thermostats

More information

Installation Instructions

Installation Instructions 30GTN015-035 Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Installation Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION.................................1-11

More information

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days Proposal Trane A Division of American Standard Inc. Prepared For: John Weston Desmet Ballestra Job Name: LAUER1 Biodiesel Chiller Pennsylvania Date: August 21, 2006 Proposal Number: G1-95502-1 Engineer:

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating Manual OM WGZ-2 Group: Chiller Part Number: 331374501 Effective: March 2005 Supercedes: OM WGZ-1 Water-Cooled Scroll Compressor Chillers WGZ 030AW To WGZ 120AW, Packaged Water-Cooled Chiller

More information

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller Operating & Maintenance Manual OMM 1166-1 Air-Cooled Scroll Compressor Chiller Group: Chiller Part No. OMM1166-1 Effective: March 2014 AGZ025D AGZ190D (ev 0A) 25 to 190 Tons 50-60-Hertz, -410A Software

More information

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller Air-Cooled Scroll Compressor Chiller Operation Manual OM AGZC-1 Group: Chiller Part Number: 331376301 Effective: February 2010 Supercedes: April 2009 AGZ 030CH through 190CH, Packaged AGZ 030CB through

More information

Product Manual SZ1022/SZ1031/SZ1035/

Product Manual SZ1022/SZ1031/SZ1035/ Product Manual SZ1022/SZ1031/SZ1035/ Conventional Heating & Cooling Thermostats Communicating Thermostats Description The SZ1022, SZ1031, and SZ1035, are microprocessorbased mable thermostats designed

More information

50AZ/UZ. for rooftop units. 50 Hz. Installation, operation and maintenance instructions

50AZ/UZ. for rooftop units. 50 Hz. Installation, operation and maintenance instructions 50AZ/UZ PRODIALOG for rooftop units Control 50 Hz Installation, operation and maintenance instructions 1 CONTENTS 1 SAFETY CONSIDERATIONS...3 1.1 General... 3 1.2 Avoid electrocution... 3 2 GENERAL DESCRIPTION...3

More information

Product Data. Features/Benefits. 17EX Externally Geared Centrifugal Liquid Chiller to 2250 Nominal Tons (5280 to 7910 kw)

Product Data. Features/Benefits. 17EX Externally Geared Centrifugal Liquid Chiller to 2250 Nominal Tons (5280 to 7910 kw) Product Data 17E Externally Geared Centrifugal Liquid Chiller 1500 to 2250 Nominal Tons (5280 to 7910 kw) Carrier s Externally Geared 17E Open Drive Centrifugal Liquid Chillers operate with environmentally

More information

Product Manual SZ1009

Product Manual SZ1009 Product Manual SZ1009 Conventional Heating & Cooling Thermostats with Heat Pump Mode Communicating Thermostats Description The SZ1009 is a microprocessor-based mable thermostats designed for conventional

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

Metasys Integrator Carrier Application

Metasys Integrator Carrier Application Application Note Issue Date April 15, 2003 Metasys Integrator Carrier Application lntroduction 3 Application Details 3 Component Requirements 6 Vendor Contact Information 7 Design Considerations 7 Cable

More information

R134a. MODEL: HXWC Series INSTALLATION, OPERATION & MAINTENANCE MANUAL. Water Cooled Screw Flooded Chillers. 60Hz. 65 to 200 Tons (229 to 703 kw)

R134a. MODEL: HXWC Series INSTALLATION, OPERATION & MAINTENANCE MANUAL. Water Cooled Screw Flooded Chillers. 60Hz. 65 to 200 Tons (229 to 703 kw) Form No: M-M-0489A-0410 Products that perform...by people who care INSTALLATION, OPERATION & MAINTENANCE MANUAL Water Cooled Screw Flooded Chillers MODEL: HXWC Series R134a 60Hz 65 to 200 Tons (229 to

More information

Owner s Manual. Part Number 33CS250-RC

Owner s Manual. Part Number 33CS250-RC CONTENTS Page GENERAL... 1 CONFIGURATION... 1-4 Transmitter Display... 1 Transmitter Indicator... 1 Transmitter Front Panel Buttons... 1 Set Clock... 2 Programming Thermostat Schedules... 3 OPERATION...5

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Table of Contents. W2W Open

Table of Contents. W2W Open W2W Open Points and Properties CARRIER CORPORATION 2013 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-457-01 3/27/2013 Table of Contents Introduction... 1

More information

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS Debonair 33CS Flush-Mounted Flatstat Commercial Programmable Thermostat IMPORTANT: Read entire instructions before programming the thermostat. Owner s Manual Part Number 33CS250-FS and 33CS220-FS GENERAL

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating Manual OM WGZC Group: Chiller Part Number: 331374501 Effective: January 2008 Supercedes: New Water-Cooled Scroll Compressor Chillers WGZ 030CW to WGZ 200CW, Packaged Water-Cooled Chiller WGZ

More information

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

Installation, Start-Up, and Operating Instructions

Installation, Start-Up, and Operating Instructions 33CS Commercial Programmable Thermostat Installation, Start-Up, and perating Instructions Part Number 33CS220-LA CNTENTS Page SAFETY CNSIDERATINS... 1 GENERAL... 1 INSTALLATIN... 1-6 Select Thermostat

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating Manual OM WGZC-2 Group: Chiller Part Number: 331975301 Effective: August 2011 Supercedes: November 2010 Water-Cooled Scroll Compressor Chillers WGZ 030CW To WGZ 200CW, Packaged Water-Cooled Chiller

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance Series R Air-Cooled Helical Rotary Liquid Chiller RTAD 085-180 (50Hz) Standard, Free Cooling and Heat Recovery models RTAD-SVX01F-E4 General information Foreword These

More information

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 9 Commissioning Checklist S9-CL2017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 S9-CL2017.doc Commissioning

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

Installation, Operation, and Troubleshooting Instructions

Installation, Operation, and Troubleshooting Instructions Installation, Operation, and Troubleshooting Instructions 48/50HJ004-024 48/50TJ004-028 Apollo Control GENERAL The Apollo control is a relay pack which is factory wired and mounted in the Carrier rooftop

More information

Metasys Integrator McQuay Application

Metasys Integrator McQuay Application Metasys Connectivity Technical Manual. Metasys Integrator Section Application Note Issue Date 000 APPLICATION NOTE Metasys Integrator McQuay Application Introduction Page * Application Details * Component

More information

CAUTION. No-Load Performance, Controls in Normal Position

CAUTION. No-Load Performance, Controls in Normal Position Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*

More information

CONTROL PANEL OPERATING MANUAL AIR-COOLED SCREW CHILLER MICROTECH III CONTROLLER D EOMAC00A10-12EN

CONTROL PANEL OPERATING MANUAL AIR-COOLED SCREW CHILLER MICROTECH III CONTROLLER D EOMAC00A10-12EN CONTROL PANEL OPERATING MANUAL AIR-COOLED SCREW CHILLER MICROTECH III CONTROLLER Table of Contents - 2 - INTRODUCTION... 3 OPERATING LIMITS:... 4 CONTROLLER FEATURES... 4 GENERAL DESCRIPTION... 5 CONTROL

More information

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller Operating and Maintenance Manual OMM 1087-1 Air-Cooled Scroll Compressor Chiller Group: Chiller Part Number: OMM 1087 Effective: May 2012 Supersedes: April 2012 AGZ-D 25 to 190 Tons 50-60-Hertz, -410A

More information

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION Bottom Mount Refrigerator Technical Information AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0! CAUTION Due to a possibility of personal injury or property damage, always contact an authorized technician

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating and Maintenance Manual OMM 1130 Group: Chiller Part Number: OMM 1130 Effective: March 2012 Supercedes: November 2011 Water-Cooled Scroll Compressor Chillers WGZ030DW to WGZ200DW, Packaged Water-Cooled

More information

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator. Bottom Mount Refrigerator Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTION

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

APOGEE Open Processor with McQuay Microtech Driver: Series 200 Centrifugal Chiller

APOGEE Open Processor with McQuay Microtech Driver: Series 200 Centrifugal Chiller Point Map Rev. 3, February, 2002 Systems Integration APOGEE Open Processor with McQuay Microtech Driver: Series 200 Centrifugal Chiller Table 1. Series 200 Centrifugal Chiller. Point Type Range/Units 01

More information

START UP FORM PACKET

START UP FORM PACKET START UP FORM PACKET Condensing Unit and Evaporator DIVISIONS OF RAE CORPORATION 4492 Hunt St. - Pryor, OK 74361 - (918) 825-7222 - Fax (918) 825-6366 www.rae-corp.com RAE Corporation Condensing Unit

More information

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years. TURBOCOR COMPRESOR CHILLERS General Description Microprocessor controlled, water chiller using HFC 134a refrigerant, two stage centrifugal oil free variable speed compressor's and electronic expansion

More information

Commercial Touchscreen Thermostat

Commercial Touchscreen Thermostat 55,13M 1/27 Supersedes 12/25 Commercial Touchscreen Thermostat 25 Lennox Industries, Inc. Dallas, Texas, USA APPLICATION Page 1 INSTALLATION INSTRUCTIONS The Lennox Commercial Touchscreen Thermostat provides

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

Installation, Start-Up, and Operating Instructions

Installation, Start-Up, and Operating Instructions Installation, Start-Up, and Operating Instructions IMPORTANT: Read entire instructions before starting the installation. SAFETY CONSIDERATIONS Read and follow manufacturer instructions carefully. Follow

More information

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program. 15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional

More information

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,

More information

Start-Up, Operation, and Maintenance Instructions

Start-Up, Operation, and Maintenance Instructions Start-Up, Operation, and Maintenance Instructions Absorption liquid chillers provide safe and reliable service when operated within design specifications. When operating this equipment, use good judgment

More information

VisionPRO 8000 with Wi-Fi

VisionPRO 8000 with Wi-Fi VisionPRO 8000 with Wi-Fi FEATURES PRODUCT DATA Thermostat acquires weather data through either a wired sensor or an Internet connection, making for a truly universal installation. U1 Terminals One set

More information

Table of Contents. i-vu CCN Standard 4.2

Table of Contents. i-vu CCN Standard 4.2 i-vu CCN Standard 4.2 Owner's Guide CARRIER CORPORATION 2009 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-381-01 7/13/2009 Table of Contents Accessing your

More information

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B 2 CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B CAUTION CAUTION - ONLY TRAINED, QUALIFIED PERSONNEL SHOULD INSTALL AND/OR SERVICE CLIMATEMASTER EQUIPMENT. SERIOUS

More information

Introduction. What is the W2W Open controller?

Introduction. What is the W2W Open controller? W2W Open CARRIER CORPORATION 2018 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-537-01 1/9/2018 Verify that you have the most current version of this document

More information

Installation, Service, and Troubleshooting Instructions

Installation, Service, and Troubleshooting Instructions Installation, Service, and Troubleshooting Instructions GENERAL...2 INSTALLATION...2-11 Thermostat Placement...2 Wiring Requirements...2 VVT Relay Packs...4 Wiring Connections for Monitor Thermostat...4

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

Rev UltraSite User s Guide BCU Supplement

Rev UltraSite User s Guide BCU Supplement 026-1004 Rev 1 09-04-97 UltraSite User s Guide BCU Supplement Computer Process Controls, Inc. 1640 Airport Road Suite #104 Kennesaw, GA 31044 Phone (770) 425-2724 Fax (770) 425-9319 ALL RIGHTS RESERVED

More information

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Bottom Mount Refrigerator Technical Information JBC2088HT* JBC2088HT*1, JBL2088HES JBL2088HES1, JBR2088HES JBR2088HES1, JFC2089HE* JFC2089HE*1, JFC2089HP* JFC2089HP*1, JFC2089HT* JFC2089HT*1, KBFA20ERBL

More information

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings ETNC-FC-BAC-PIR- Rev. Index Operating instructions....- Turning the thermostat and OFF Selecting temperature scale Adjusting the Set point temperature (for set point and set points configurations) Selecting

More information

Sales and Engineering Data Sheet ED

Sales and Engineering Data Sheet ED Sales and Engineering Data Sheet ED 15121-7 Group: Controls Part Number: ED 15121 Date: July 2017 MicroTech III Chiller Unit Controller Protocol Information Modbus Networks ANSI/ASHRAE 135-2004, BACnet

More information

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz 30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB

More information

D A R A - 4. Data Aire Relay Auto-Changeover

D A R A - 4. Data Aire Relay Auto-Changeover D A R A - 4 Data Aire Relay Auto-Changeover WARNING: If adding the DARA-4 panel to existing units that did not include a DARA-4 panel when originally purchased it will be necessary to add a relay or relays.

More information

CAUTION: ELECTRICAL HAZARD

CAUTION: ELECTRICAL HAZARD R R Installation Guide 53DF50-HW hermostat System ypes Cool Only (single stage) Heat Pump (with electric heat) CAUION: ELECRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power

More information

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa

More information