Gas Water Heaters. Use & Care Manual

Size: px
Start display at page:

Download "Gas Water Heaters. Use & Care Manual"

Transcription

1 ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Compliant with South Coast Air Quality Management District Rule ng/j NOx Emissions Gas Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, for the owner operator, to explain the features, operation, safety precautions, maintenance and troubleshooting of the water heater. This manual also includes a parts list. It is imperative that all persons who are expected to install, operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations. If you do not understand these instructions or any terms within it, seek professional advice. Any questions regarding the operation, maintenance, service or warranty of this water heater should be directed to the seller from whom it was purchased. If additional information is required, refer to the section on If you need service. Do not destroy this manual. Please read carefully and keep in a safe place for future reference.!! Low NOx Emissions FVIR Certified Recognize this symbol as an indication of Important Safety Information! California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.! WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.! FOR YOUR SAFETY! Do not store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Do not return to your home until authorized by the gas supplier or fire department. Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, or death. Refer to this manual. Installation and service must be performed by a qualified installer, service agency or the gas supplier. DESIGN DO NOT RETURN this water heater to the store or place of purchase. If you need technical or installation assistance, please call the Technical Support Lines at CERTIFIED AP (03/17)

2 Safety Information Safety Precautions LP Gas Models... 5 Installation Instructions Location... 7 Water Supply Connections.. 9 Gas Supply FOR YOUR RECORDS Write the model and serial numbers here: # # You can find them on a label on the appliance. Staple sales slip or cancelled check here. Proof of the original purchase date is needed to obtain service under the warranty. Pipe Insulation...13 Heat Traps...13 Wiring Diagram Installation Checklist...17 Potable/Space Heating Operating Instructions Lighting Instructions Water Temperature... 20, 21 READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your water heater properly. A little preventive care on your part can save you time and money over the life of your water heater. You ll find many answers to common problems in the Troubleshooting Guide. If you review the chart of Troubleshooting Tips first, you may not need to call for service. Care and Cleaning Draining Maintenance Burner Inspection Extended Shut-Down...24 Troubleshooting Tips Before You Call For Service... 25, 26 Customer Service Parts List If You Need Service...32 READ THE SAFETY INFORMATION Your safety and the safety of others are very important. There are many important safety messages in this manual and on your appliance. Always read and obey all safety messages.! This is the safety alert symbol. Recognize this symbol as an indication of Important Safety Information! This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word DANGER, WARNING, CAUTION or NOTICE. These words mean:!!! DANGER WARNING CAUTION NOTICE: An imminently hazardous situation that will result in death or serious injury. A potentially hazardous situation that could result in death or serious injury and/or damage to property. A potentially hazardous situation that may result in minor or moderate injury. Attention is called to observe a specified procedure or maintain a specific condition. 2

3 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and money. Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death. Should you have problems understanding the instructions in this manual, or have any questions, STOP, and get help from a qualified service technician, or the local gas utility.! DANGER! INSTALL THE DRAFT HOOD AND PROPERLY VENT THE WATER HEATER Failure to install the draft hood and properly vent the water heater to the outdoors as outlined in the Venting Section of the Installation Instructions in this manual can result in unsafe operation of the water heater. To avoid the risk of fire, explosion, or asphyxiation from carbon monoxide, never operate this water heater unless it is properly vented and has an adequate air supply for proper operation. Be sure to inspect the vent system for proper installation at initial start-up; and at least annually thereafter. Refer to the Care and Cleaning section of this manual for more information regarding vent system inspection.! WARNING! Gasoline, as well as other flammable materials and liquids which include, but are not limited to (adhesives, solvents, paint thinners etc.), and the vapors they produce are extremely dangerous. DO NOT handle, use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water heater or any other appliance. Be sure to read and follow warning label pictured below and other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in property damage, bodily injury or death.! W ARNING FLAMMABLES Flammable Vapors! FIRE AND EXPLOSION HAZARD Can result in serious injury or death. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death. 3

4 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.! DANGER! WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of a water heater s gas control. Water temperatures above 125 F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on the water heater. Time/Temperature Relationship in Scalds Water Temperature Time To Produce a Serious Burn 120 F More than 5 minutes 125 F 1 1 /2 to 2 minutes 130 F About 30 seconds 135 F About 10 seconds 140 F Less than 5 seconds 145 F Less than 3 seconds 150 F About 1 1 /2 seconds 155 F About 1 second Table courtesy of Shriners Burn Institute NOTICE: Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines. Contact a licensed plumber or the local plumbing authority for further information.! DANGER: Hotter water increases the potential for Hot Water SCALDS. The chart shown above may be used as a guide in determining the proper water temperature for your home.! DANGER: Households with small children, disabled, or elderly persons may require a 120 F or lower gas control (thermostat) setting to prevent contact with HOT water. Maximum water temperatures occur just after the burner has shut off. To find water temperature being delivered, turn on a hot water faucet and place a thermometer in the water stream and read the thermometer.(see page 20 and 21 for more details.) The temperature of the water in the heater can be regulated by setting the temperature dial on the front of the Combination Gas Control (thermostat). To comply with safety regulations the Combination Gas Control(thermostat) was set at its lowest setting before the water heater was shipped from the factory. The illustration on the following page details the approximate water temperature for each LED indicator of the Combination Gas Control (thermostat). 4

5 Thermostat Water Temperature Details VACATION WARM A B C VERY HOT COOLER HOTTER WARNING! DANGER: Hotter water increases the potential for Hot Water SCALDS. Temperature Setting for 160 F Thermostat Display A B C Burns on Adult Skin WARM = approx. 70 F (21 C) = approx. 120 F (49 C) More than 5 minutes A = approx. 130 F (54 C) About 30 seconds B = approx. 140 F (60 C) Less than 5 seconds C = approx. 150 F (66 C) About 1-1/2 seconds C-Flashing = approx. 160 F (71 C) About 1/2 seconds WARM B C D E F VERY HOT COOLER HOTTER WARNING! DANGER: Hotter water increases the potential for Hot Water SCALDS. Temperature Setting for 180 F Thermostat Display Burns on Adult Skin = approx. 120 F (49 C) More than 5 minutes B = approx. 130 F (54 C) About 30 seconds C = approx. 140 F (60 C) Less than 5 seconds D = approx. 150 F (66 C) About 1-1/2 seconds E = approx. 160 F (71 C) About 1/2 seconds F = approx. 170 F (77 C) F = approx. 180 F (82 C)

6 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.! DANGER! LIQUEFIED PETROLEUM (LP) AND NATURAL GAS MODELS LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions, such as odorant fade, which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak. Water heaters utilizing LP gas are different from natural gas models. A natural gas water heater will not function safely on LP gas and vice versa. No attempt should ever be made to convert the water heater from natural gas to LP gas. To avoid possible equipment damage, personal injury or fire, do not connect the water heater to a fuel type not in accordance with the unit data plate. LP for LP units. Natural gas for natural gas units. These units are not certified for any other fuel type. LP appliances should not be installed below grade (for example, in a basement) if such installation is prohibited by federal, state and/or local laws, rules, regulations or customs. LP gas must be used with great caution. It is heavier than air and will collect first in lower areas making it hard to detect at nose level. Before attempting to light the water heater, make sure to look and smell for gas leaks. Use a soapy solution to check all gas fittings and connections. Bubbling at a connection indicates a leak that must be corrected. When smelling to detect a gas leak, be sure to sniff near the floor also. Gas detectors are recommended in LP & natural gas applications and their installation should be in accordance with the detector manufacturer s recommendations and/or local laws, rules, regulations or customs. It is recommended that more than one method, such as soapy solution, gas detectors, etc., be used to detect leaks in gas applications.! DANGER: If a gas leak is present or suspected: DO NOT attempt to find the cause yourself. DO NOT try to light any appliance. DO NOT touch any electrical switch. DO NOT use any phone in your building. Leave the house immediately and make sure your family and pets leave also. Leave the doors open for ventilation and contact the gas supplier, a qualified service agency or the fire department. Stay away from the house (or building) until the service call has been made, the leak is corrected and a qualified agency has determined the area to be safe. 6

7 WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions. For residential water heaters up to 52-gallon capacity, a brochure with generic earthquake bracing instructions can be obtained from: Office of the State Architect, 1102 Q Street, Suite 5100, Sacramento, CA or you may call or ask a water heater dealer. However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons, consult the local building jurisdiction for acceptable bracing procedures. SAFETY PRECAUTIONS Have the installer show you the location of the gas shut-off valve and how to shut it off if necessary. Turn off the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or if the gas supply fails to shut off. Read this manual entirely before installing or operating the water heater. Use this appliance only for its intended purpose as described in this Use and Care Manual. Be sure your appliance is properly installed in accordance with local codes and the provided installation instructions. DO NOT attempt to repair or replace any part of your water heater unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS 7

8 Installing the water heater. This water heater must be installed in accordance with these instructions, local codes, utility company requirements, and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 N. Capitol Street NW, Washington, DC as ANSI standard Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA as booklet NFPA 54. Max. 2 Flammable Vapor Sensor The auxiliary catch pan installation MUST conform to local codes. Top View Alcove Rear Front Open Front Enclosed Diameter of water heater plus 2 min. NOTICE: DO NOT allow the flammable vapour sensor to become submerged in water. Make sure the catch pan is properly drained. Sides Top View Closet Rear Sides! WARNING: Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials. Combustible and/or flammable products and materials should never be stored in the vicinity of this or any gas appliance. 8 Location The water heater should not be located in an area where leakage from the tank or connections will result in damage to the area adjacent to the heater or to lower floors of the structure. When such areas cannot be avoided it is recommended that a suitable catch pan, adequately drained, must be installed under the water heater. The pan must not restrict air flow to the combustion air inlet openings (perforation openings) located around the lower perimeter of the water heater. Catch pan kits are available from the store where the water heater was purchased, or any water heater distributor. Make certain the floor underneath the water heater is strong enough to sufficiently support the weight of the water heater once it is filled with water. A gas fired water heater or any other appliance should not be installed in a space where liquids which give off flammable vapors are to be used or stored. Such liquids include gasoline, LP gas (butane or propane), paint or adhesives and their thinners, solvents or removers. DO NOT block or obstruct the Flammable Vapor Sensor. Because of natural air movement in a room or other enclosed space, flammable vapors can be carried some distance from where liquids which give off flammable vapors are to be used or stored. The open flame of the water heater s main burner can ignite these vapors and create a shut down condition of the water heater which will not allow the water heater to ignite until examined by a Qualified Service Technician. FVIR certified gas water heaters can be installed on a residential garage floor without the use of an 18-inch stand in accordance with the National Fuel Gas Code, NFPA 54, ANSI Z223.1, unless otherwise directed by State and Local code requirements. The water heater must be located so it is not subject to physical damage, for example, by moving vehicles, area flooding, etc The water heater should be installed as close as practical to the gas vent or chimney. Long hot water lines should be insulated to conserve water and energy. The water heater and water lines should be protected from exposure to freezing temperatures. DO NOT install the water heater in bathrooms, bedrooms, any occupied rooms normally kept closed, or in unprotected outdoor areas. Minimum clearance from combustible construction: Location Front* Sides Rear Top** Alcove (7.6 cm) (0 cm) (0 cm) (30.5 cm) Closet 3 (7.6 cm) 0 (0 cm) 0 (0 cm) 12 (30.5 cm) * "Front" Clearance dimension is measured from the water heater jacket to the closet door. ** "Top" clearance dimension is measured from the jacket top of the water heater to the ceiling. If the clearances stated on the Instruction/ Warning Label, located on the front of the heater differ, install the water heater according to the clearances stated on the label. If the water heater is installed in an alcove or closet, the entire floor must be covered by a wood or metal panel. A minimum of 24 clearance from the front and top should be available for adequate inspection and servicing. The water heater may be installed on combustible floors, but not directly on carpeting. If the water heater must be installed on carpeting, place a metal or wood panel beneath the water heater, extending beyond its full width and depth at least 3 in all directions.

9 Inspect Shipment Carefully inspect the water heater for damage before proceeding with the installation. Of specific interest should be any dents or damage to the blower or plenum assembly. If you find damage, DO NOT install or attempt any repair to the water heater. Contact the manufacturer as detailed under "IF YOU NEED SERVICE" on page 32. Combustion and Ventilation Air Proper operation of the water heater requires air for combustion and ventilation. Provisions for combustion and ventilation air must comply with referenced codes and standards. When installed in a closet, DO NOT block or obstruct any of the combustion air inlet openings located around the perimeter of the outer door. A minimum of 1 is required between these combustion air inlet openings and any obstruction. NOTICE: If the water heater is installed in an unconfined space within a building of conventional frame, masonry or metal construction, infiltration air is normally adequate for proper combustion and ventilation. If the water heater is installed in a confined space, provisions for combustion and ventilation air must be made. A confined space is one having a volume of less than 50 cubic feet per 1000 Btuh of the aggregate input of all appliances within that space. The air must be supplied through two permanent openings of equal area. One is to be located within 12 above the floor and the other is to be located within 12 from the ceiling. The minimum net free area of each opening must not be less than one square inch per 1000 Btuh of the total input rating of all the appliances in the enclosure (but not less than 100 square inches), if each opening communicates with other unconfined areas inside the building. Buildings of unusually tight construction shall have the combustion and ventilation air supplied from outdoors, or a freely ventilated attic or crawl space. If air is supplied from outdoors, directly or through vertical ducts, there must be two openings located as specified above and each must have a minimum net free area of not less than one square inch per 4000 Btuh of the total input rating of all the appliances in the enclosure. If horizontal ducts are used to communicate with the outdoors, each opening must have a minimum net free area of not less than one square inch per 2000 Btuh of the total input rating of all the appliances in the enclosure. If ducts are used, the minimum dimensions of rectangular air ducts shall not be less than 3. NOTICE: If the duct openings which supply combustion and ventilation air are to be covered with a protective screen or grill, the net free area (openings in the material) of the covering material must be used in determining the size of the openings. Protective screening for the openings MUST NOT be smaller than 1/4 mesh to prevent clogging by lint or other debris. NOTICE: The water heater should not be installed near an air supply containing halogenated hydrocarbons. Corrosive Atmospheres The air in beauty shops, dry cleaning establishments, photo processing labs, and storage areas for liquid and powdered bleaches or swimming pool chemicals often contain such halogenated hydrocarbons. An air supply containing halogenated hydrocarbons may be safe to breathe, but when it passes through a gas flame corrosive elements are released that will shorten the life of any gas burning appliance. Propellants from common spray cans or gas leaks from A/C and refrigeration equipment are highly corrosive after passing through a flame. The water heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere. 9

10 Installing the water heater. IMPORTANT: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the cold water connections on heater. Any heat applied to the cold water supply fittings will permanently damage the dip tube and the heat traps in the hot/cold nipples. NOTICE: The National Fuel Gas Code (NFGC) mandates a manual gas shut-off valve: See (NFGC) for complete instructions. Local codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions. Thermal Expansion Determine if a check valve exists in the inlet water line. Check with your local water utility company. It may have been installed in the cold water line as a separate back flow preventer, or it may be part of a pressure reducing valve, water meter or water softener. A check valve located in the cold water inlet line can cause what is referred to as a closed water system. A cold water inlet line with no check valve or back flow prevention device is referred to as an open water system. As water is heated, it expands in volume and creates an increase in the pressure within the water system. This action is referred to as thermal expansion. In an open water system, expanding water which exceeds the capacity of the water heater flows back into the city main where the pressure is easily dissipated. A closed water system, however, prevents the expanding water from flowing back into the main supply line, and the result of thermal expansion can create a rapid and dangerous pressure increase in the water heater and Water Supply Connections Refer to the illustration below for suggested typical installation. The installation of unions or flexible copper connectors is recommended on the hot and cold water connections so that the water heater may be easily disconnected Typical Installation Vent connector to chimney Hot water outlet to fixtures Heat trap 6 minimum Water Heater Jacket Temperature and pressure relief valve Manual gas shut-off To gas supply Ground joint union Sediment trap Cap Combination Gas Control (thermostat) Flammable Vapor Sensor Jacket door Union system piping. This rapid pressure increase can quickly reach the safety setting of the relief valve, causing it to operate during each heating cycle. Thermal expansion, and the resulting rapid, and repeated expansion and contraction of components in the water heater and piping system can cause premature failure of the relief valve, and possibly the heater itself. Replacing the relief valve will not correct the problem! The suggested method of controlling thermal expansion is to install an expansion tank in the cold water line between the water heater and the check valve (see illustration below). The expansion tank is designed with an air cushion built in that compresses as the system pressure increases, thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve. Other methods of controlling thermal expansion are also available. Contact your installing contractor, water supplier or plumbing inspector for additional information regarding this subject. for servicing if necessary. The HOT and COLD water connections are clearly marked and are 1 NPT on all models. Install a shut-off valve in the cold water line near the water heater. Shut-off valve Drain valve Pitch up 1/4 per foot Draft hood Anode Union Thermal expansion tank (if required) Heat trap 6 minimum To cold water supply Shut-off valve Relief valve discharge line to suitable open drain. Auxiliary catch pan 10 Drain Pan Pipe to suitable drain. 6 Air gap

11 A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must remain in the opening provided and marked for the purpose on the water heater. No valve of any type should be installed between the relief valve and the tank. Local codes shall govern the installation of relief valves. Relief Valve The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate. The Btuh rating of the relief valve must equal or exceed the Btuh input of the water heater as marked on its rating plate. Position the outlet of the relief valve above a suitable open drain to eliminate potential water damage. Piping used should be of a type approved for hot water distribution. The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage (by gravity) of the relief valve and discharge line. The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction, or reducer coupling should be installed in the discharge line. WARNING: The tank must be full of water before heater is turned on. The water heater warranty does not cover damage or failure resulting from operation with an empty or partially empty tank. To Fill the Water Heater Make certain that the drain valve is closed, then open the shut-off valve in the cold water supply line. Open each hot water faucet slowly to allow the air to vent from the water heater and piping. A steady flow of water from the hot water faucet(s) indicates a full water heater. Condensation Condensation can form on the tank when it is first filled with water. Condensation might also occur with a heavy water draw and very cold inlet water temperatures. Drops of water falling on the burner can produce a sizzling or pinging sound. This condition is not unusual, and will disappear after the water becomes heated. If, however, the condensation continues, examine the piping and fittings for possible leaks. 11

12 Installing the water heater. WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Gas Supply The branch gas supply line to the water heater should be clean properly sized black steel pipe or other approved gas piping material. A union or ANSI design certified semirigid or flexible gas appliance connector should be installed in the gas line close to the water heater. The National Fuel Gas Code (NFGC) mandates a manual gas shut-off valve: See (NFGC) for complete instructions. Compound used on the threaded joints of the gas piping must be of the type resistant to the action of LP gas. Use compound sparingly on male threads only. Where a sediment trap is not incorporated as part of the appliance, a sediment trap shall be installed downstream of the equipment shutoff valve as close to the inlet of the appliance as practical at the time of the appliance installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. Do not use excessive force (over 31.5 ft lbs.) in tightening the pipe joint at the Combination Gas Control (thermostat) inlet, particularly if teflon pipe compound is used, as the valve body may be damaged. The inlet gas pressure to the water heater must not exceed 14 w.c. for natural gas. For purposes of input adjustment, the minimum inlet gas pressure (with main burner on) is shown on the water heater rating plate. If high or low gas pressures are present, contact your gas supplier for correction. WARNING: Never use an open flame to test for gas leaks, as property damage, personal injury, or death could result. Leak Testing The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation. Turn on the manual gas shut-off valve near the water heater. Use a soapy water solution to test for leaks at all connections and fittings. Bubbles indicate a gas leak that must be corrected. Pressure Testing the Gas Supply System The water heater and its manual gas shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 3/8 psi (10.5 w.c.) for natural gas. The factory connections to the gas control (thermostat) should also be leak tested after the water heater is placed in operation. The water heater must be isolated from the gas piping system by closing the manual gas shut-off valve during any pressure testing of the gas supply piping at pressures equal to or less than 3/8 psi (10.5 w.c.) for natural gas. WARNING: Failure to install a water heater suitable for the altitude at the location it is intended to serve, can result in improper operation of the appliance resulting in property damage and/or, producing carbon monoxide gas, which could result in personal injury, or death. 12 High Altitude This water heater is certified for installations up to 8,500 feet above sea level.! WARNING: Installations above 8,500 feet are not authorized and may result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of acceptable limits, which could result in serious injury or death.

13 The water heater must be installed with the factory supplied draft hood in place. DANGER: Failure to install the draft hood and properly vent the water heater to the outdoors as outlined in the Venting section of this manual will result in unsafe operation of the water heater causing bodily injury, explosion, fire or death. To avoid the risk of fire, explosion, or asphyxiation from carbon monoxide, NEVER operate the water heater unless it is properly vented and has adequate air supply for proper operation as outlined in the Venting Section of this manual. WARNING: If local codes require external application of insulation blanket kits the manufacturer s instructions included with the kit must be carefully followed. Venting This water heater is a Category I -Fanassisted appliance. Vent connectors must be attached to the draft hood outlet to connect the water heater to the gas vent or chimney. The vent connectors must be the same size (diameter) as the draft hood or larger, never smaller. For proper venting in certain installations a larger vent connector size may be needed. Consult the latest version of the National Fuel Gas Code (ANSI Z223.1/NFPA 54). Multi-story and common venting is permitted. Consult the latest version of the National Fuel Gas Code (ANSI Z233.1/ NFPA 54). Insulation Blankets Insulation blankets, available to the general public, for external use on gas water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary. The manufacturer s warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices. Horizontal vent connectors must be pitched upward to the chimney at least 1/4 per foot of length. Single wall vent connectors must be at least 6 from adjacent unprotected combustible surface. Vent joints must be securely fastened by sheet metal screws or other approved method. Test for spillage at the draft hood relief opening after 5 minutes of main burner operation. Use a flame of a match or candle or smoke. The flame or smoke should be pulled into the draft hood s relief opening(s). CAUTION: If local codes require the application of an external insulation blanket to this water heater, pay careful attention to the following so as not to restrict the proper function and operation of the water heater: DO NOT cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket. DO NOT apply insulation to the top of the water heater. This will interfere with the safe operation of the draft hood. DO NOT cover the burner access door, jacket door, gas control (thermostat)/gas valve or pressure and temperature relief valve. DO NOT apply insulation to the bottom of the water heater or the area where the combustion air inlet openings are located. This area must be unobstructed so as not to restrict combustion air flow to the burner. DO NOT apply insulation to the area where the flammable vapor sensor is located. This area must be unobstructed so as not to restrict air flow to the sensor. Inspect the insulation blanket frequently making certain it has not sagged and is restricting the air flow to the combustion air inlet openings located around the perimeter of the water heater outer door. This could result in an unsafe operating condition. 13

14 Installing the water heater. Wiring This water heater may be connected to electric service with the power cord provided (DO NOT use an extension cord). A grounding receptacle is required. If local codes do not permit the use of cord connections, a 120 V, 50/60 Hz power supply, with suitable disconnecting means, must be connected to the black and white leads in the blower assembly. The maximum current draw is less than 5.0 amps. The water heater must be electrically grounded in accordance with local codes, or, in the absence of local codes, in accordance with latest edition of the National Electric Code ANSI/NFPA No. 70 in US and for Canada the Canadian Electrical Code CSA C22.1. Refer to the figures below for water heater internal wiring. 120 VAC PLUG FOR POWERVENT BLOWER ASSEMBLY H PRISE DE 120 VCA POUR G L ENSEMBLE DE N SOUFFLEUR D ÉVENT MÉCHANIQUE POWER VENT BLOWER ASSEMBLY ENSEMBLE DU SOUFFLEUR D ÉVENT MÉCANIQUE GAS VALVE SOUPAPE DE GAZ GND BLOWER SOUFFLEUR INTELLI-VENT ELECTRONIC CONTROL CONTRÔLE ÉLECTRONIQUE INTELLI-VENT MOT SCREW GND VIS DE MISE À LA TERRE J W BK BK W CONNECTOR DIAGRAM SCHÉMA DES CONNEXIONS FLAMMABLE VAPOR SENSOR DÉTECTEUR DE VAPEUR INFLAMMABLE BL FV Y R BK W G N/C PRESSURE SW NO CONTACTEUR À DÉPRESSION W 6 PIN CONNECTOR CONNECTEUR À 6 BROCHES IGNITER AND FLAME SENSOR ALLUMEUR ET CAPTEUR DE FLAMME WIRE HARNESS THAT RUNS FROM BLOWER ASSEMBLY TO INTELLIVENT CONTROL GAS VALVE FAISCEAU DE CÂBLAGE ENTRE L ENSEMBLE DU SOUFFLEUR ET LA INTELLI-VENT DE LA SOUPAPE DE CONTRÔLE DU GAZ ANY REPLACEMENT IGNITOR CABLE MUST BE RATED AT 250º C TOUT CÂBLE D ALLUMAGE DE REMPLACEMENT DOIT ÊTRE ÉTALONNÉ Á 250º C BK G W ON/OFF SWITCH CONTACTEUR MARCHE/ARRÉT 120V 50/60 Hz LESS THAN 5 AMPS H H ON/OFF SWITCH CONTACTEUR MARCHE/ARRÉT GAS VALVE SOUPAPE DE GAZ INTELLI-VENT ELECTRONIC CONTROL CONTRÔLE ÉLECTRONIQE INTELLI-VENT SCHEMATIC DIAGRAM SCHÉMA DE CABLÂGE 120 VAC BL N/C Y R BK W W BK BK W BK = BLACK/NOIR BL = BLUE/BLEU G = GREEN/VERT R = RED/ROUGE W = WHITE/BLANC Y = YELLOW/JAUNE IGNITER ALLUMEUR W FLAMMABLE VAPOR SENSOR DÉTECTEUR DE VAPEUR INFLAMMABLE FLAME SENSOR CAPTEUR DE FLAMME PRESSURE SW NO CONTACTEUR À DÉPRESSION BLOWER SOUFFLEUR MOT GND NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH A 18 GA, 600 V, 105º C WIRE. REMARQUE: SI UNE PARTIE QUELCONQUE DU CÂBLAGE ORIGINAL FOURNI AVEC L APPAREIL DOIT ÊTRE REMPLACÉE, ELLE DOIT ÊTRE REMPLACÉE AVEC UN FIL DE CALIBRE 18, 600 VCA, 105º C. AX5185 N N CAUTION! Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING! 14

15 Hot and Cold Pipe Insulation Installation Typical vertical piping arrangement For increased energy efficiency, some water heaters have been supplied with two 24 sections of pipe insulation. Please install the insulation, according Typical horizontal piping arrangement to the illustrations above, that best meets your requirements. Temperature & Pressure Relief Valve (T&P) Insulation Installation For increased energy efficiency, this water heater has been supplied with a 2 3/8 section of T&P insulation. Please install the insulation as shown below. Typical Side Connect T & P Arrangement. Slip the insulation cover over the T&P Valve through the center hole and align the hole in the side with the opening of the T&P Valve. Heat Traps For increased energy efficiency, some water heaters have been supplied with heat traps for installation in the hot outlet line and cold water inlet line. Typical Top Connect T & P Arrangement. Ensure the T&P Valve opening is not obstructed by the insulation. These heat traps may require a minimum of one (1) 90 elbow and may require an additional 90 elbow or a 3/4 coupling depending on your installation needs. See Illustration of nipples and heat traps on page

16 Installing the water heater. During Installation of this water heater... DO DO check inlet gas pressure to ensure that it is within the range specified on the rating plate. DO provide adequate air for combustion and ventilation as discussed in the Use and Care Manual and the National Fuel Gas Code. DO maintain proper clearances to combustibles as specified on the rating plate. DO ensure that the venting system complies with the guidelines found in the Use and Care Manual and National Fuel Gas Code. DO contact a qualified service technician if the hot surface ignitor or main burner will not stay lit. The burner chamber is designed to be sealed utilizing a gasket. DON T DON T block or restrict the flammable vapor sensor located around the lower portion of the water heater jacket. DON T block or restrict Combustion Air Inlet Openings located around the outer door. DON T remove the Burner Access Door unless absolutely necessary. This should only be done by a qualified service technician. A new burner access door gasket must be installed on any burner access door that has been removed. DON T install this water heater where standing water may occur. The base of the water heater is meant to be mounted on a dry surface. DON T allow cleaners, solvents, or other like materials to come in contact with the flammable vapor sensor. DON T allow cleaner, solvents, or other materials to come in contact with the flammable vapor sensor. DON T operate the water heater if the sight glass or burner access door grommet is damaged or broken. Burner Access Door Grommet Sight Glass Flammable Vapor Sensor 16

17 Installation Checklist A. Water Heater Location q Close to area of vent. q Indoors and protected from freezing temperatures. q Proper clearance from combustible surfaces observed and water heater not installed on carpeted floor. q Sufficient fresh air supply for proper operation of water heater. q Air supply free of corrosive elements and flammable vapors. q Catch pan installed. q Sufficient room to service the water heater. q Combustible materials, such as clothing, cleaning materials, rags, etc. clear of the base of the heater. q Clearances from combustion air inlet openings observed (see page 9). q Flammable vapor sensor is not blocked.. q Provisions made to protect area from water damage. B. Water Supply q Water heater completely filled with water. q Water connections tight and free of leaks. q Air purged from water heater and piping. C. Gas Supply q Gas line equipped with shut-off valve, union and sediment trap. q Approved pipe joint compound used. q Soap and water solution used to check all connections and fittings for possible gas leak. q Gas Company inspected installation (if required). D. Relief Valve q Temperature and Pressure Relief Valve properly installed and discharge line run to open drain. q Discharge line protected from freezing. E. Venting q Flue baffle properly hung in top of heater s flue. q Draft hood properly installed. q Vent connector(s) pitched upward to chimney (¼" per foot of length minimum). q Vent connector(s) securely fastened together with screws. q Single wall vent connector(s) at least 6 from combustible material. F. Wiring q Correct power supply (120 VAC). q Electrical connections tight. q Water heater properly grounded and proper polarity observed. 17

18 Supplemental instructions for gas water heaters installed in potable/space heating applications. Local codes or plumbing authority requirements may vary from the instructions or diagrams provided in this manual and take precedent over these instructions. Hot water supply to heating unit Hot water supply to house From HOT outlet on water heater Tee fitting for vertical hot water supply lines. Hot water supply to house From HOT outlet on water heater Hot water supply to heating unit Tee fitting for horizontal hot water supply lines. Combination Potable and Space Heating Application Tee fitting must be installed as shown. This ensures that any air in the water lines will be purged through the domestic water faucets and showers. DANGER: When this system requires water for space heating at elevated temperatures (above 125 F [52 C.]), a mixing or tempering valve must be installed in the hot water supply line to the house in order to reduce the scald hazard potential. DANGER: Any piping or components used in the installation of this water heater in a combination potable and space heating application must be suitable for use with drinking water. Typical Piping Diagram for Combination Potable/Space Heating Installation Nominal 3/4" size mixing or tempering valve (refer to warning above). Follow mixing or tempering valve manufacturer s instructions for installation of the valve. Spring loaded check valve in heating unit hot water supply line and cold water return line (not supplied with water heater) NOTICE: This check valve is incorporated in some heating units. Refer to the installation instructions supplied with specific heating unit to determine if it is required. See diagrams above for proper pipe application for vertical or horizontal supply lines. Isolation valve in hot water supply line to heating unit (not supplied with water heater) Temperature and Pressure Relief Valve, tie to location approved by local code Minimum of 2'-0" developed length of 3/4" pipe. 3/4" Shut- Off Valve (Typ.) Air vent 3/4" Tempered domestic hot water supply to house. Heat Trap 6 Min. 2 Gallon Thermal Expansion Tank (if required-not supplied with water heater) DANGER: If this water heater is installed in an application intended to supply domestic hot water needs and hot water for space heating purposes, do not connect the heater to an existing heating unit or components of a heating system that have previously been used with a non drinking water system. Toxic chemicals such as those used for boiler treatment may be present and will contaminate the drinking water supply causing possible health risks. Never introduce toxic chemicals, such as those used for boiler treatment, into this system. NOTICE: 50 ft maximum distance from water heater to fan coil (developed length) is required for Massachusetts state. 3/4" Shut-Off Valve (Typ.) 140 F 120 to 130 F Pressure Gauge 3/4" Check Valve with 1/8" Hole 3/4" Shut-Off Valve (Typ.) 3/4" cold water supply Hot water to space heater Hot water coil All bronze pump. Check valve internal in pump. Air bleed valve. Water Sample Tap. Gas line to water heater Temperature and pressure relief valve discharge line Water heater jacket Combination Gas Control (Thermostat) Water Heater drain pan installed in accordance with the Local and State Code Gas Fired Water Heater Drain valve (not supplied with water heater) Isolation valve in cold water return line from heating unit (not supplied with water heater) Gas Direct Vent discharge must comply with Local and State Code 3/4" HWS & HWR to Heating Coil. Air Handler To HVAC Unit. T FAN ON OFF HEAT COOL Flammable Vapor Sensor Water Heater to be in accordance with the Local and State Energy Code Vacuum Relief Valve (Not Supplied) Electronically controlled pump timer. Activates every 6 hours for 60 seconds. Wire to bronze pump. All water piping shall be insulated in accordance with Local and State Energy Code Air Gap If required, install per local codes and valve manufacturer s instructions. 18

19 VACATION WARM A B C VERY HOT Lighting the water heater. Before operating this water heater, be sure to read and follow the instructions on the label pictured below and all other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resulting in property damage, personal injury, or death. Should you have any problems reading or following the instructions in this manual, STOP, and get help from a qualified person. A. B. FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions and the Use & Care Manual instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do NOT try to light the burner by hand. BEFORE PUTTING THIS APPLIANCE INTO SERVICE - Smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in the gas control buttons. Never use tools. If the control buttons will not push in, don t try to repair them, call a qualified service technician. Force or attempted repair may result in fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced! OPERATING INSTRUCTIONS 1. Stop! Read the safety information above 8. on this label. 2. Toggle the ON/OFF switch located on the 9. blower assembly to the ON position. 3. Set the thermostat to the lowest setting by pressing the COOLER and HOTTER buttons at the same time and holding them for (1) second. Depress the COOLER button until only the WARM indicator light is lit. 4. Toggle the ON/OFF switch located on the blower assembly to the OFF position. 5. Turn off all electrical power to the appliance. 6. This appliance is equipped with a Hot Surface Ignition System which automatically lights the burner. Do NOT open the inner door of this appliance and try to light the burner by hand! 7. Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow B in the safety information above on this label. If you do not smell gas, go ahead to the next step. Turn on all electrical power to the appliance. Toggle the ON/OFF switch located on the blower assembly to the ON position. 10. Set thermostat to the desired temperature setting by pressing the COOLER and HOTTER buttons at the same time and holding them for (1) second. Depress the HOTTER button until the desired temperature display setting is lit. The preferred starting point for temperature setting is indicated by on the thermostat. 11. If the appliance will not operate, follow the instructions TO TURN OFF GAS TO APPLIANCE and call your service technician or gas supplier. TO TURN GAS OFF TO THE APPLIANCE 1. Set the thermostat to the lowest setting by first depressing the COOLER and HOTTER buttons at the same time and holding for (1) second. Depress the COOLER button until only the WARM indicator light is lit. 2. Toggle the ON/OFF switch located on the blower assembly to the OFF position. 3. Turn off all electrical power to the appliance. COOLER WARNING HOTTER 19

Residential Gas - FVIR Certified

Residential Gas - FVIR Certified ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified Water Heaters The

More information

Gas Water Heaters. Use & Care Manual

Gas Water Heaters. Use & Care Manual ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Compliant with South Coast Air Quality Management

More information

Residential Gas - FVIR Certified

Residential Gas - FVIR Certified ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified Induced Draft Water

More information

Residential Gas - Low NOx Emissions

Residential Gas - Low NOx Emissions ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Compliant with South Coast Air Quality Management

More information

Gas Water Heaters. Use & Care Manual. FVIR Certified. With Installation Instructions for the Installer. 75 and 98 Gallon

Gas Water Heaters. Use & Care Manual. FVIR Certified. With Installation Instructions for the Installer. 75 and 98 Gallon ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer FVIR Certified Gas Water Heaters 75 and 98 Gallon

More information

Light Duty Gas Commercial 60 Gallon

Light Duty Gas Commercial 60 Gallon ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Light Duty Gas Commercial 60 Gallon Water Heaters

More information

Water Heaters Residential 30, 38, 40, 50 and 60 Gallon

Water Heaters Residential 30, 38, 40, 50 and 60 Gallon Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas Water Heaters Residential 30, 38, 40,

More information

Residential 30, 38, 40, 50, 55 and 60 Gallon

Residential 30, 38, 40, 50, 55 and 60 Gallon ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified Water Heaters The

More information

Residential Gas - FVIR Certified WITH DAMPER & ELECTRONIC CONTROL

Residential Gas - FVIR Certified WITH DAMPER & ELECTRONIC CONTROL ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified Water Heaters WITH

More information

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10) Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

Solar Water Heater. Use & Care Manual. FVIR Certified. Residential Gas - With Installation Instructions for the Installer

Solar Water Heater. Use & Care Manual. FVIR Certified. Residential Gas - With Installation Instructions for the Installer ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Residential Gas - Use & Care Manual With Installation Instructions for the Installer FVIR Certified Solar Water Heater

More information

Direct Vent Water Heaters

Direct Vent Water Heaters ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified Direct Vent Water

More information

Side Inlet - Direct Vent Gas. For Manufactured Housing

Side Inlet - Direct Vent Gas. For Manufactured Housing Use & Care Manual With Installation Instructions for the Installer Side Inlet - Direct Vent Gas Water Heaters For Manufactured Housing The purpose of this manual is twofold: one, to provide the installer

More information

Use & Care Manual. Residential Gas - FVIR Certified Direct Vent Water Heaters. With Installation Instructions for the Installer

Use & Care Manual. Residential Gas - FVIR Certified Direct Vent Water Heaters. With Installation Instructions for the Installer ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified Direct Vent Water

More information

For Manufactured Home (Mobile Home) Installations

For Manufactured Home (Mobile Home) Installations Use & Care Manual With Installation Instructions for the Installer Side Inlet Gas Water Heaters For Manufactured Home (Mobile Home) Installations The purpose of this manual is twofold: one, to provide

More information

Use & Care Manual. With Installation Instructions for the Installer Direct Vent Gas - FVIR Certified

Use & Care Manual. With Installation Instructions for the Installer Direct Vent Gas - FVIR Certified Use & Care Manual With Installation Instructions for the Installer Direct Vent Gas - FVIR Certified Water Heaters 40 and 50 Gallon Vertical Co-Axial Vent System The purpose of this manual is twofold: one,

More information

For Manufactured Housing

For Manufactured Housing Use & Care Manual With Installation Instructions for the Installer Side Inlet Gas - FVIR Certified Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions

More information

Side Inlet - Direct Vent Gas. For Manufactured Housing

Side Inlet - Direct Vent Gas. For Manufactured Housing Use & Care Manual With Installation Instructions for the Installer Side Inlet - Direct Vent Gas Water Heaters For Manufactured Housing The purpose of this manual is twofold: one, to provide the installer

More information

! This is the safety alert symbol. Recognize this symbol

! This is the safety alert symbol. Recognize this symbol ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified PowerDirect Vent

More information

TANKLESS WATER HEATER USE AND CARE MANUAL

TANKLESS WATER HEATER USE AND CARE MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing death, personal injury, or property damage. For Your Safety! Do not store or use gasoline

More information

Gas Water Heaters. Use & Care Manual. FVIR Compliant. ! Recognize this symbol as an indication of Important Safety Information!

Gas Water Heaters. Use & Care Manual. FVIR Compliant. ! Recognize this symbol as an indication of Important Safety Information! VACATION WARM COOLER A B C WARNING VERY HOT HOTTER! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer

More information

Water Heaters. Use & Care Manual. Electric Residential. With Installation Instructions for the Installer. Double Element Residential Electric Models

Water Heaters. Use & Care Manual. Electric Residential. With Installation Instructions for the Installer. Double Element Residential Electric Models Use & Care Manual With Installation Instructions for the Installer Electric Residential Water Heaters Double Element Residential Electric Models The purpose of this manual is twofold: one, to provide the

More information

Tankless Water Heater

Tankless Water Heater WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable

More information

Water Heaters. Manufactured under trademark license by: Rheem Manufacturing Company P.O. Box , Montgomery, AL

Water Heaters. Manufactured under trademark license by: Rheem Manufacturing Company P.O. Box , Montgomery, AL Use & Care Manual With Installation Instructions for the Installer Electric Residential Water Heaters Single and Double Element Models, Residential 20 120 Gallon Model: HE Series, GE Series, PE Series,

More information

TANKLESS WATER HEATER USE AND CARE MANUAL

TANKLESS WATER HEATER USE AND CARE MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing death, personal injury, or property damage. For Your Safety! Do not store or use gasoline

More information

Water Heaters. Use & Care Manual. Gas Residential. With Installation Instructions for the Installer. Residential 40 and 50 Gallon

Water Heaters. Use & Care Manual. Gas Residential. With Installation Instructions for the Installer. Residential 40 and 50 Gallon ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! Gas Residential The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

Commercial Indoor and Outdoor Gas Tankless Water Heater

Commercial Indoor and Outdoor Gas Tankless Water Heater Installation and Operating Instruction Manual R With Installation Instructions for the Installer Commercial Indoor and Outdoor Gas Tankless Water Heater Indoor Water Heater Outdoor Water Heater The purpose

More information

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Infinion C13 Installation and Operation Manual NOTICE TO INSTALLER Affix these instructions adjacent to the Infinion. NOTICE TO OWNER Keep these instructions for future reference. For additional information,

More information

Side Inlet - Direct Vent Gas

Side Inlet - Direct Vent Gas Use & Care Manual With Installation Instructions for the Installer Side Inlet - Direct Vent Gas Water Heaters For Manufactured Housing (Mobile Home) The purpose of this manual is twofold: one, to provide

More information

Tankless Water Heater

Tankless Water Heater Residential Indoor Gas Use & Care Manual With Installation Instructions for the Installer Tankless Water Heater 199,900 BTU Max Input The purpose of this manual is twofold: one, to provide the installer

More information

Water Heaters. Residential Gas - FVIR Certified. Use & Care Manual. With Installation Instructions for the Installer

Water Heaters. Residential Gas - FVIR Certified. Use & Care Manual. With Installation Instructions for the Installer ! Warning: This water heater is not suitable for use in manufactured (mobile) homes! Use & Care Manual With Installation Instructions for the Installer Residential Gas - FVIR Certified Model shown with

More information

Water Heaters. Use & Care Manual. Gas Residential - FVIR Certified. With Installation Instructions for the Installer. Residential 40 and 50 Gallon

Water Heaters. Use & Care Manual. Gas Residential - FVIR Certified. With Installation Instructions for the Installer. Residential 40 and 50 Gallon ! WARNING: This water heater is not suitable for use in manufactured (mobile) homes! The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on

More information

Phone: Address: A Industrial RD Summerville, SC 29483

Phone: Address: A Industrial RD Summerville, SC 29483 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable

More information

HIGH EFFICIENCY CONDENSING TANKLESS WATER HEATER USE AND CARE MANUAL

HIGH EFFICIENCY CONDENSING TANKLESS WATER HEATER USE AND CARE MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing death, personal injury, or property damage. For Your Safety! Do not store or use gasoline

More information

Residential Gas Water Heater USE & CARE MANUAL

Residential Gas Water Heater USE & CARE MANUAL Residential Gas Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR The purpose of this manual is twofold: for the installing contractor, to provide requirements and recommendations

More information

Gas Residential Water Heaters. Residential 40 and 50 Gallon

Gas Residential Water Heaters. Residential 40 and 50 Gallon Use & Care Manual With Installation Instructions for the Contractor Gas Residential Water Heaters Residential 40 and 50 Gallon The purpose of this manual is twofold: one, for the installing contractor,

More information

INSTALLATION & SERVICE MANUAL

INSTALLATION & SERVICE MANUAL GAS-FIRED WATER HEATER If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. INSTALLATION & SERVICE MANUAL

More information

Tankless Water Heater

Tankless Water Heater Installation and Operating Instruction Manual With Installation Instructions for the Installer Residential Outdoor Gas 199,900 BTU Max Input Tankless Water Heater The purpose of this manual is twofold:

More information

Tankless Water Heater

Tankless Water Heater Residential Indoor and Outdoor Gas R Installation and Operating Instruction Manual With Installation Instructions for the Installer Tankless Water Heater Indoor Water Heater Outdoor Water Heater The purpose

More information

Residential Gas Hybrid Water Heater

Residential Gas Hybrid Water Heater Residential Gas Hybrid Water Heater USER S INFORMATION MANUAL WGRGH20NG75F / WGRGH20NG76F / WGRGH20NG100F WGRGHNG75F / WGRGHNG76F / WGRGHNG100F Models* *A suffix of LP denotes propane gas NOTICE: Westinghouse

More information

Tankless Water Heater

Tankless Water Heater Tankless Water Heater USER S INFORMATION MANUAL Models WGRT**150 / WGRT**199 / WGRTC**199 **A suffix of LP denotes propane gas **A suffix of NG denotes natural gas NOTICE: Westinghouse reserves the right

More information

Tankless Water Heater

Tankless Water Heater Indoor and Outdoor Gas Use & Care Manual With Installation Instructions for the Installer Tankless Water Heater Models: Indoor Water Heater Outdoor Water Heater PH-16 (FISN)(FISP) PH20R-(IFSN)(IFSP)(OFN)(OFP)

More information

Universal Fire Tube Boiler Wall Mount Models

Universal Fire Tube Boiler Wall Mount Models Universal Fire Tube Boiler Wall Mount Models USER S INFORMATION MANUAL Models WBRU**80W / 100W / 120W / 140W / 175W / 199W **NG denotes Natural Gas Model, LP Denotes Propane Model Heat Exchanger Bears

More information

USE & CARE MANUAL. Commercial Gas Water Heater WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR FOR YOUR SAFETY!

USE & CARE MANUAL. Commercial Gas Water Heater WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR FOR YOUR SAFETY! Commercial Gas Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR MULTI-FLUE COMMERCIAL MODELS TREME Unit * Standard Burner Unit GNU: Power Assisted * Power Assist Burner

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR

More information

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Gas Fired Residential Combi Boiler Floor and Wall Mount Models Gas Fired Residential Combi Boiler Floor and Wall Mount Models USER S INFORMATION MANUAL Models WBRC**140W WBRC**199W WBRC**140F WBRC**199F ** NG Refers to Natural Gas Operation LP Refers to Propane Gas

More information

Use & Care Manual. Electric Residential Water Heaters. With Installation Instructions for the Installer

Use & Care Manual. Electric Residential Water Heaters. With Installation Instructions for the Installer Use & Care Manual With Installation Instructions for the Installer Electric Residential Water Heaters Single and Double Element Models, With Energy Cover The purpose of this manual is twofold: one, to

More information

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGE RESULTING FROM FAILURE TO COMPLY WITH THESE INSTRUCTIONS. READ THESE

More information

INSTALLATION & SERVICE MANUAL

INSTALLATION & SERVICE MANUAL INSTALLATION & SERVICE MANUAL ELECTRIC WATER HEATER THE WARRANTY ON THIS WATER HEATER IS IN EFFECT ONLY WHEN THE WATER HEATER IS INSTALLED AND OPERATED IN ACCORDANCE WITH LOCAL CODES AND THESE INSTRUCTIONS.

More information

Installation Instructions and Use & Care Guide

Installation Instructions and Use & Care Guide Ultra Low Nox Gas Water Heater with the Flammable Vapor Ignition Resistant Safety System WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing

More information

Internet Version for Reference Only STORAGE UNIT

Internet Version for Reference Only STORAGE UNIT STORAGE UNIT A Spanish language version of these instructions is available by contacting the manufacturer listed on the rating plate. La version espanola de estas instrucciones se puede obtener al escribirle

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-51012-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest w ater heaters on

More information

RESIDENTIAL GAS WATER HEATERS FVIR GAS WATER HEATER (FLAMMABLE VAPOR IGNITION RESISTANT) FOR SPACE HEATING AND POTABLE WATER HEATING ONLY.

RESIDENTIAL GAS WATER HEATERS FVIR GAS WATER HEATER (FLAMMABLE VAPOR IGNITION RESISTANT) FOR SPACE HEATING AND POTABLE WATER HEATING ONLY. Installation Instructions and Use & Care Guide RESIDENTIAL GAS WATER HEATERS FVIR GAS WATER HEATER (FLAMMABLE VAPOR IGNITION RESISTANT) FOR SPACE HEATING AND POTABLE WATER HEATING ONLY. NOT FOR USE IN

More information

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents Installation Instructions T 9822 Gas Dryer To prevent accidents en - US, CA and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 2 WARNING For your safety the information

More information

Residential Gas Water Heater with the Flame Guard Safety System Installation Instructions and Use & Care Guide (Flammable Vapor Ignition Resistant)

Residential Gas Water Heater with the Flame Guard Safety System Installation Instructions and Use & Care Guide (Flammable Vapor Ignition Resistant) WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable

More information

RESIDENTIAL GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

RESIDENTIAL GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS RESIDENTIAL GAS-FIRED WATER HEATERS (EQUIPPED WITH FVIR TECHNOLOGY) OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS This water heater IS NOT design certified for installation in a manufactured (mobile)

More information

TWO GALLON ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

TWO GALLON ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL TWO GALLON ELECTRIC WATER HEATER A Spanish language version of these instructions is available by contacting the manufacturer listed on the rating plate. La version Espanola de estas instrucctions se puede

More information

Water Heaters. Use & Care Manual. Electric Residential. With Installation Instructions for the Installer

Water Heaters. Use & Care Manual. Electric Residential. With Installation Instructions for the Installer Electric Residential Water Heaters Use & Care Manual With Installation Instructions for the Installer Single and Double Element Models, Residential 0 0 Gallon The purpose of this manual is twofold: one,

More information

Residential Gas Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide

Residential Gas Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Installation and Operating Manual RESIDENTIAL GAS WATER HEATERS POWER VENTED GAS MODELS WITH HOT SURFACE IGNITION NOT FOR USE IN MANUFACTURED (MOBILE) HOMES WARNING: If the information in these instructions

More information

Residential Solar Water Heater with Heat Exchanger. Solariade Water Heater with Heat Exchanger (Front View)

Residential Solar Water Heater with Heat Exchanger. Solariade Water Heater with Heat Exchanger (Front View) Residential Solar Water Heater with Heat Exchanger USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR LISTED 786H Solariade Water Heater with Heat Exchanger (Front View) The purpose of

More information

USE & CARE MANUAL. Residential Solar Water Heater with Heat Exchanger WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

USE & CARE MANUAL. Residential Solar Water Heater with Heat Exchanger WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR Residential Solar Water Heater with Heat Exchanger USE & CARE MANUAL ALTERNATE-ENERGY WATER-STORAGE TANK 52L6 WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR The purpose of this manual is twofold: one,

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL TWO-STAGE SAFETY CONDENSING GAS FURNACES Recognize this symbol as an indication of Important Safety Information IMPORTANT: All manufacturer products

More information

GAS COOKTOP INSTALLATION INSTRUCTIONS

GAS COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING If the information

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Instruction Manual RESIDENTIAL GAS WATER HEATERS NOT FOR USE IN MANUFACTURED (MOBILE) HOMES INSTALLATION - OPERATION - SERVICE - MAINTENANCE Low Lead Content WARNING: If the information in these instructions

More information

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS WATER HEATER STORAGE GAS Lead Paint Risk Factor NONE TABLE OF CONTENTS PART 1: INSTALLATION REQUIREMENTS FOR CONVENTIONAL HOMES... 1 WATER HEATER REPAIR... 1 1. APPLIANCE REPAIR... 1 WATER HEATER INSTALLATION...

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR PERFORMER SLIDE-IN COOK TOPS MODEL NUMBERS: AROBSCT-424, AROBSCT-242GD, AROBSCT-24X2GR, AROBSCT-430, AROBSCT-636, AROBSCT-436GD, AROBSCT-436GR,

More information

ULTRA LOW NOX RESIDENTIAL GAS WATER HEATERS

ULTRA LOW NOX RESIDENTIAL GAS WATER HEATERS Instruction Manual ULTRA LOW NOX RESIDENTIAL GAS WATER HEATERS NOT FOR USE IN MANUFACTURED (MOBILE) HOMES LOW LEAD CONTENT For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. ALL

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Instruction Manual RESIDENTIAL GAS WATER HEATERS NOT FOR USE IN MANUFACTURED (MOBILE) HOMES For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. ALL TECHNICAL AND WARRANTY QUESTIONS:

More information

Elite. User s Information Manual. Elite and Elite VWH* All Models

Elite. User s Information Manual. Elite and Elite VWH* All Models Elite User s Information Manual Elite and Elite VWH* All Models Heat Exchanger Bears the ASME H Stamp IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING

More information

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater Contents Section Page Major Components... 2 1 About Our Manual... 2 2 Refractory Handling...

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Installation Instructions and Use & Care Guide RESIDENTIAL GAS WATER HEATERS 300 Maddox Simpson Parkway Lebanon, TN 37090 Phone: 615-889-8900 Fax: 615-547-1000 Technical Services email: 2tech@lochinvar.com

More information

User s Information Manual Models: 45, ,000 Btu/hr

User s Information Manual Models: 45, ,000 Btu/hr SBR-USER_100161678_2000017137_Rev C User s Information Manual Models: 45,000-260,000 Btu/hr If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,

More information

Energy Smart Gas Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide

Energy Smart Gas Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

Installation Instructions and Use & Care Guide

Installation Instructions and Use & Care Guide VAC WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline

More information

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER. Instruction Manual RESIDENTIAL GAS WATER HEATERS NOT FOR USE IN MANUFACTURED (MOBILE) HOMES Low Lead Content For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. ALL TECHNICAL AND

More information

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE USERS INFORMATION MANUAL MODELS FOR USE WITH NATURAL GAS MHA-50N, MHA-75N, MHA-100N, MHA-125N, MDA-50N, MDA-75N, MDA-100N, MDA-125N FOR USE

More information

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD. 2017 Lennox Industries Inc. Dallas, Texas, USA 506897-01 04/2017 Supersedes 10/2015 EL280DF SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL OPERATING INSTRUCTIONS AND OWNER S MANUAL MR. HEATER READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has

More information

POWER VENTED GAS WATER HEATERS

POWER VENTED GAS WATER HEATERS Installation and Operating Manual POWER VENTED GAS WATER HEATERS 300 Maddox Simpson Parkway Lebanon, TN 37090 Phone: 615-889-8900 Fax: 615-547-1000 Technical Services email: 2tech@lochinvar.com www.lochinvar.com

More information

Light Duty Commercial Electric Water Heater USE & CARE MANUAL

Light Duty Commercial Electric Water Heater USE & CARE MANUAL Light Duty Commercial Electric Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE INSTALLER LISTED 786H The purpose of this manual is twofold: one, to provide the installer with the

More information

MODELS BT- 80 AND 100

MODELS BT- 80 AND 100 MODELS BT- 80 AND 100 COMMERCIAL GAS WATER HEATER Glass-Lined Tank-Type Water Heater INSTALLATION OPERATION SERVICE MAINTENANCE LIMITED WARRANTY Thank you for buying this energy efficient water heater

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Instruction Manual RESIDENTIAL GAS WATER HEATERS POWER VENT/POWER DIRECT VENT GAS MODELS WITH DIRECT SPARK IGNITION MODELS VG6250T100/VGD6275T100 SERIES 130/131 www.americanwaterheater.com American Water

More information

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Installation and Operating Manual RESIDENTIAL GAS WATER HEATERS POWER DIRECT VENT GAS MODELS WITH HOT SURFACE IGNITION NOT FOR USE IN MANUFACTURED (MOBILE) HOMES : If the information in these instructions

More information

Use & Care Manual. Electric Residential Water Heaters. With Installation Instructions for the Installer. Single and Double Element Models,

Use & Care Manual. Electric Residential Water Heaters. With Installation Instructions for the Installer. Single and Double Element Models, Use & Care Manual With Installation Instructions for the Installer Electric Residential Water Heaters Single and Double Element Models, The purpose of this manual is twofold: one, to provide the installer

More information

Commercial High Efficiency Water Heater

Commercial High Efficiency Water Heater Commercial High Efficiency Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR DESIGN CERTIFIED Recognize this symbol as an Indication of Important Safety Information Do Not

More information

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT Installation instructions for your new Spacemaker Laundry WSM2780 Gas Before you begin Read these instructions completely and carefully. IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer

More information

Installation Instructions and Use & Care Guide

Installation Instructions and Use & Care Guide WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable

More information

ML180UH SERIES GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING 2017 Lennox Industries Inc. Dallas, Texas, USA 506525-01 04/2017 Supersedes 10/2015 ML180UH SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Instruction Manual RESIDENTIAL GAS WATER HEATERS POWER VENT/POWER DIRECT VENT GAS MODELS WITH DIRECT SPARK IGNITION MODELS GDHE-50/GDHE-75 SERIES 130/131 Ashland City, TN 37015 www.hotwater.com Thank you

More information

GAS-FIRED WATER HEATER

GAS-FIRED WATER HEATER GAS-FIRED WATER HEATER A Spanish language version of these instructions is available by contacting the company listed on the rating plate. La versión espãnola de estas instrucciones se puede obtener al

More information

GAS-FIRED WATER HEATER

GAS-FIRED WATER HEATER GAS-FIRED WATER HEATER A Spanish language version of these instructions is available by contacting the company listed on the rating plate. La version Espanola de estas instrucciones se puede obtener al

More information

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416)

More information

OPERATIONS MANUAL 5 LITER LPG GAS TANKLESS WATER HEATER C AMPER SERIES

OPERATIONS MANUAL 5 LITER LPG GAS TANKLESS WATER HEATER C AMPER SERIES OPERATIONS MANUAL 5 LITER LPG GAS TANKLESS WATER HEATER C AMPER SERIES MODEL # AGL-5 DRAKKEN INDUSTRIES LLC 790 W. 20 th St. Suite-103, Hialeah, FL. 33010 Toll:1-888-818-4328 Table of Contents Use and

More information