1 TD Series MATERIAL DRYER INSTRUCTION MANUAL I.O.M. #046 11/98 INSTALLATION OPERATION MAINTENANCE of TD-15, TD-5, TD-50 models 55 EAST STOP 18 ROAD GREENWOOD, IN 4614 PHONE: FAX:

2

3 TD Series MATERIAL DRYER INSTRUCTION MANUAL TD SERIES MATERIAL DRIER COVERING INSTALLATION OPERATION MAINTENANCE of TD-15, TD-5, TD-50 models 55 EAST STOP 18 ROAD GREENWOOD, IN 4614 PHONE: FAX:

4 Note: This page intentionally left blank. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 4

5 TABLE OF CONTENTS 1.0 GENERAL Introduction 8 1. Safety 8 1. Unpacking General Inspection Material Safety Summery 8.0 INSTALLATION 11.1 TD Series Installation 1. Diffuser cone or Diffuser Tube Installation 1. Utility Connection 1.0 OPERATIONS 15.1 Description of Operation 16. Initial Start-up Procedure 16. Operating Procedure 17.4 Temperature Controller TROUBLESHOOTING Overview 0 4. Machine will not Start 0 4. Inadequate or No Regeneration Heat Inadequate or No Process Heat Inadequate or No Adsportion Air Flow Inadequate Dew Point 4.7 Changeover Temperature Too High 4.8 Maintenance and Inspection Schedule 5.0 RELATED DRAWINGS TD-15 Physical (115/1/60) 6 5. TD-15 Physical with 60# hopper 7 5. TD-15 Electrical (115/1/60) TD-5 Physical (0/1/ TD-5 Physical (460/1/60) TD-5 Electrical (0/1/60) TD-5 Electrical (460/1/60) 5.8 TD-5 0V with 100# Hopper on Stand 5.9 TD-5 0V Physical with Stand TD-5 460V with 100# Hopper Physical TD-50 Physical TD-50 0V Physical TD V Physical TD-50 Physical with 00# Hopper (460V) TD-50 Electrical East Stop 18 Road Greenwood, Indiana Fax: Page: 5

6 Note: This page intentionally left blank. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 6

7 1.0 GENERAL 1.1 INTRODUCTION 1. SAFETY 1. UNPACKING 1.4 GENERAL INSPECTION 1.5 MATERIAL SAFETY SUMMARY 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 7

8 1.1 INTRODUCTION 1. SAFETY 1. UNPACKING A. TEMPTEK TD Series Material Dryer is a continuous-duty, desiccant dryer designed to supply an uninterrupted flow of constant, low dew point air. The unit is completely automatic and requires very little maintenance to offer many years of trouble free service. A. It is important to become thoroughly familiar with this manual and the operating characteristics of the TD SERIES material dryer. B. It is the owner s responsibility to assure proper operator training, installation, operation, and maintenance of the TD SERIES material dryer. C. Observe all warning and safety placards applied to the chiller. Failure to observe all warnings can result in serious injury or death to the operator and severe mechanical damage to the unit. A. Caution should be exercised to see that the equipment is not handled roughly. The crate must be removed carefully. The machine must not be used to pry against when removing the crate. B. The dryer is usually shipped completely assembled and require no further assembly prior to installation. Do not tilt the dessicant section at an angle greater than 0 during unpacking of installation because the desiccant may get into the valve assembly. 1.4 GENERAL INSPECTION A. When the unit is unpacked, make a visual inspection looking for missing parts or damage which may have occurred during shipment. B. Some parts, such as thermometers, hoses, and hose clamps are packed inside the hopper. All electrical and mechanical connections should be checked for tightness because vibration during transit may cause them to loosen. C. The inside of the hopper and the perforated spreader cone or diffuser tube should be thoroughly cleaned to remove all dust and oil that may have accumulated during shipment to your plant. 1.5 MATERIAL SAFETY SUMMARY A. Some components used by TEMPTEK may contain mercury, a chemical listed in the EPA (Environmental Protection Agency) Title III chemical list, EPA identification number The 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 8

9 Adjustable quick release stainless steel band clamps with safety latch Loader pattern on lid with cover plate High efficiency 1 x molecular sieve desiccant High efficiency 15, 5 or 50 CFM blower Cyclone dual stage cartridge filter removes fines to 1 micron One piece stainless door Electrically controlled valve Easy opening heavy duty door latches and strikes... piano hinged door with silicone gasket Electrical Cabinet Breakthrough in Air diffuser Technology Controller (not visible in this photograph) Optional material drain out with stainless steel slide gate on sizes 60lb. and up Rigid cast aluminum mounting adapter for strength and stability Optional stainless steel slidegate Inlet thermometer port Tubular heaters with incoloy sheath for process temperatures to 00 F Vacuum loader (seeloader literature for details) Dual bed stainless steel construction with automatic regeneration Easily accessed maintenance points Optional floor stand shown with casters... (available without casters) Stainless steel modular hopper shown: Painted exterior Smooth Interior with no internal projections 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 9

10 components are typically (i) mercury switch and/or (ii) mercury relay switches. These devices are listed as ARTICLES and as such are exempt from the COMMUNITY RIGHT TO KNOW per Title III. B. Shipping requirements according th IATA (International Air Transport Authority) regulation 805 indicate that mercury switches and relays are exempt from the requirements of IATA regulation 805 providing they are of the totally enclosed leak-proof type in sealed metal or plastic units. All devices used by TEMPTEK meet these requirements, and as such require no special packing. C. Check the parts lists included with this instruction manual for the presence of devices containing mercury that may have supplied with your equipment from TEMPTEK. Material Safety Data sheets for these devices and other special precaution have been provided in this manual. This information should be reviewed if applicable. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 10

11 .0 INSTALLATION.1 TD SERIES INSTALLATION. DIFFUSER CONE OR DIFFUSER TUBE INSTALLATION. UTILITY CONNECTION 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 11

12 Note: This page intentionally left blank. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 1

13 .1 TD SERIES INSTALLATION A. Mount the TD Dryer and hopper combination (if purchased) to the processing machine, using an adapter if necessary. Secure with bracing as required to stabilize the unit. Convenient lugs are located at the end and on the valve box for this purpose. Others may be used if necessary. B. Connect the required electrical power to the unit as indicated on the Temptek nameplate, which is located on the face of the control box. C. If an optional hopper, dryer, or combination hopper/dryer stand has been supplied by TEMPTEK, it should securely bolted to the floor for a safe installation. then connect the hoses, thermocouple, etc., as described under the appropriate sections in this manual.. DIFFUSER CONE OR DIFFUSER TUBE INSTALLATION A. After the hopper has been installed and secured, the perforated diffuser cone or diffuser tube should be installed in the hopper. The cone rests on a flange inside the hipper hear the bottom of the straight side (just below the clean out door if applicable) where it joins the outer hopper cone. This cone maybe installed either thru the clean out door (if supplied) or by removing the hopper lid. Be certain the diffuser cone is seated firmly to the flange inside the hopper. B. The diffuser tube is installed by pressing it in to the hopper inlet tube from inside the hopper. Either a perforated diffuser cone or diffuser tube (not both) is supplied depending on the size and design of the hopper.. UTILITY CONNECTION A. Connect the proper supply through a main line disconnect switch (field supplied) to the terminal block marked L1 - L - L and ground in the control cabinet. B. The correct power supply requirements can be found on the specifications sheet or on the nameplate attached to the dryer. C. Local or national electrical codes should be followed as required. This is the only power supply necessary as the dryer is completely pre-wired and supplied with a control voltage transformer to supply 115 volts to the control circuit (if applicable)..1 DESCRIPTION OF OPERATION 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 1

14 Note: This page intentionally left blank. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 14

15 .0 INSTALLATION.1 DESCRIPTION OF OPERATION. INITIAL START-UP PROCEDURE. OPERATING PROCEDURE.4 TEMPERATURE CONTROLLER 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 15

16 A. The TD Series Dryer was designed to be a simple, compact and easy to use dryer that could be used for drying of plastics in cases where the throughput is 5 lbs./hr or less. B. The reduction of moisture is accomplished by the use of an adsorbent material called Molecular Sieves. The blower draws humid air from the drying hopper across the filter by the blower assembly and then it is directed through the valve assembly and into one of the desiccant beds. Moisture is adsorbed by the desiccant and the dry, low dewpoint, extremely dry air is blown across the process heater, heated to the desired temperature, discharged from the dryer and ducted to the drying hopper. The dry air enters, and is forced through, the hopper. The warm, low dew point air fills the hopper, placing all of the entering material in a moisture free environment. This causes the moisture in the plastic material to migrate to the surface where it is picked up by the dry air. The humid air is taken back to the dryer where the moisture is absorbed by the desiccant. Before the bed adsorption reaches the saturation point, the -way valve automatically reverses and transfers the humid air flow to the opposite bed. C. While one bed is on adsorption, the opposite bed is on regeneration. During regeneration, a portion of the air flow is diverted through the second desiccant bed instead of travelling through the process heater. The air passes through the regeneration heater and desiccant bed. The desiccant is heated to the temperature required to desorb the water adsorbed by the desiccant during the preceding drying period. Water vapor carried from the bed by the air is discharged to the ambient through the regeneration outlet port. At the end of the regeneration heating cycle, the regeneration heater is shut down but the dry purge air continues to flow. This helps to carry some of the excess heat of regeneration away from the desiccant bed, allowing it to cool in preparation for the adsorption cycle. D. At the end of the timed 4 hour period, a simple shift of the solenoid valve causes the diverter valves to change position. The freshly regenerated bed now begins adsorbing moisture and the other bed is regenerated. Just one blower (the process blower) is required for both the process and regeneration functions and it runs continuously when the dryer is on. Adsorption and regeneration alternative automatically between the two beds in a continuous cycle.. INITIAL START-UP PROCEDURE A. Fill the hopper completely with material and turn the temperature controller to 0 F. Push the on/off switch to the on position and check the blower for proper rotation by observing the rotation of the motor at the end facing the control box. The proper rotation is 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 16

17 indicated by an arrow on the blower housing. B. Allow the unit to dry-cyle for 4 hours with the hopper filled with material before operating. This will allow the moisture adsorbed by the desiccant during transit or inactivity to be discharged. Failure to dry cycle the unit may cause drying problems with the material. NOTE: It is necessary to have material in the hopper in order for the regeneration cycle to function properly.. OPERATING PROCEDURE 4.1 OVERVIEW A. After the initial start-up period, adjust the temperature controller to the drying temperature necessary for the material to be dried. Dry the plastic pellets for the required residence period, which is generally two to six hours depending on the material. B. After the residence period is complete, the material is dry and ready for processing. As dry material is withdrawn from the bottom, wet material should be added to the hopper at the same rate. (Note: it is extremely important to keep the hopper as full as possible for proper drying.) 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 17

18 .4 TEMPERATURE CONTROLLER PV (green): Displays the Process Value. During setup this displays the parameter to be programmed. SET: Used to change the set value (SV). During setup this scrolls, selects and confirms control settings and security modes. OUT (green): Lights when the control output is on. SV (orange): Displays the Set Value. during setup this displays the parameter value. ALM1 and ALM (red): Lights when the alarm output(s) are on. Two separate alarm functions. TEMPTEK only uses ALM1. AT (green): flashes during autotuning. LEFT ARROW: Controls cursor movement for selecting digits in the SV display. UP and DOWN ARROWS: Value selection. INITIAL SETTINGS SETTING SL1 SL SL SL4 SL5 SL6 SL7 SL8 PB oh AH 1 AH SLH SLL Note: initial set mode cannot be reached unless the LCK parameter (see below) is set to "0000". To enter the initial set mode... press and hold the SET and LEFT ARROW keys simultaniously for five seconds; (SL1) will display. Scrol through the settings with the SET key. Exit initial set mode the same way it was entered. DESCRIPTION Input type (type J T/C) Units = F / 0010 = C Heater break alarm (not used) ALM 1 type (Hi Dev) with alarm hold action ALM (not used) control Output - PID reverse action Alarm Section Not used Preset value (PV) blas ON/OFF Action gap setting Alarm 1 gap setting Alarm gap setting Hi limit set value (SV) Lo limit set value (SV) PRE-SET PARAMETER SETTINGS SETTING AL1 ATU P I D Ar T LCK To access the parameter setting mode... press the SET key for more than five seconds; (AL1) will display. Scroll through the parameters with the SET key. Exit paramter set mode the same way it was entered. DESCRIPTION Alarm 1 deviation value 0= auto-tunning start / 1 = auto-tunning stop Proportional band Integral time Derivative time Anti-reset windup (1 to 100%) Proportional cycle (1 to 100 sec) DATA Lock PRE-SET Determine by Auto-tunning East Stop 18 Road Greenwood, Indiana Fax: Page: 18

19 4.0 TROUBLESHOOTING 4.1 OVERVIEW 4. MACHINE WILL NOT START 4. INADEQUATE OR NO REGENERATION HEAT 4.4 INADEQUATE OR NO PROCESS HEAT 4.5 INADEQUATE OR NO ADSPORTION AIR FLOW 4.6 INADEQUATE DEW POINT 4.7 CHANGEOVER TEMPERATURE TOO HIGH 4.8 MAINTENANCE AND INSPECTION SCHEDULE 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 19

20 A. Most drying problems are the result of dirty filter(s), air leaks, desiccant contamination and malfunctioning regeneration heaters. It is seldom that other components fail. 4. MACHINE WILL NOT START PROBLEM: Machine will not start. SOLUTIONS: 1. POWER SUPPLY. a. No voltage or the voltage is incorrect. Check the field installed disconnect and incoming power supply.. TRANSFORMER. a. No voltage on primary. Check the field installed disconnect and incoming power supply. b. No voltage on secondary.check fuse, if ok replace the transformer.. STOP/START SWITCH. a. No voltage through the switch. Replace the switch. 4. INADEQUATE OR NO REGENERATION HEAT PROBLEM: Inadequate or No Regeneration Heat SOLUTIONS: 1. CAM TIMER. Voltage to timer motor but time doesn t rotate. a. Check for a cam switch malfunction and replace timer. b. Check for incorrect cam setting and adjust.. HEATER AMPERAGE READING. See Engineering Data sheet. a. If voltage is correct, replace heater. b. If voltage is incorrect, supply correctly rated voltage.. VALVE SOLENOID. a. Check for voltage at solenoid. If none is present, check the cam timer. If there is voltage to timer motor but time doesn t rotate, replace the timer, or check for incorrect cam setting and adjust. b. If there is voltage at the solenoid and the valve moves freely by hand, replace the valve solenoid. 4. FILTER. a. Filter is dirty. Replace element. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 0

21 5. AIR DUCTS. a. Air ducts are obstructed. Remove the obstruction. 4.4 INADEQUATE OR NO PROCESS HEAT PROBLEM: Inadequate or No Process Heat SOLUTIONS: 1. ADSORPTION MOTOR. a. Voltage at motor, amperage incorrect. Replace motor.. HEATER AMPERAGE READING. See Engineering Data sheet. a. If voltage is correct, replace heater. b. If voltage is incorrect, supply correctly rated voltage.. FILTER. a. Filter is dirty. Replace element. 4. AIR DUCTS. a. Air ducts are obstructed. Remove the obstruction. 5. PROCESS HEATER TEMPERATURE CONTROLLER. a. Adjustment incorrect. Adjust. b. No voltage across switch. Replace controller. 4.5 INADEQUATE OR NO ADSORPTION AIR FLOW PROBLEM: Inadequate or No Adsorption Air Flow SOLUTIONS: 1. POWER SUPPLY. a. No voltage or the voltage is incorrect. Check the field installed disconnect and incoming power supply.. CAM TIMER. Voltage to timer motor but time doesn t rotate. a. Check for a cam switch malfunction and replace timer. b. Check for incorrect cam setting and adjust.. FILTER. a. Filter is dirty. Replace element. 4. AIR DUCTS. a. Air ducts are obstructed. Remove the obstruction. 4.6 INADEQUATE DEW POINT PROBLEM: Inadequate Dew point SOLUTIONS: 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 1

22 1. CAM TIMER. Voltage to timer motor but time doesn t rotate. a. Check for a cam switch malfunction and replace timer. b. Check for incorrect cam setting and adjust.. HEATER AMPERAGE READING. See Engineering Data sheet. a. If voltage is correct, replace heater. b. If voltage is incorrect, supply correctly rated voltage.. VALVE SOLENOID. a. Check for voltage at solenoid. If none is present, check the cam timer. If there is voltage to timer motor but time doesn t rotate, replace the timer, or check for incorrect cam setting and adjust. b. If there is voltage at the solenoid and the valve moves freely by hand, replace the valve solenoid 4. FILTER. a. Filter is dirty. Replace element. 5. AIR DUCTS. a. Air ducts are obstructed. Remove the obstruction. 6. LEAKS IN SYSTEM. a. Air leaking in or out of system. Replace gaskets and repair leaks as necessary. 7. DESICCANT. a. Contaminated. Replace desiccant. b. Saturated. Dry cycle for 4 hours. 8. DEWPOINT METER. a. Not operating properly. Repair or replace meter. b. Reverse flow through meter. Make sure of positive pressure at the dewpoint sample port. 4.7 CHANGEOVER TEMPERATURE TOO HIGH PROBLEM: Changeover Temperature too high SOLUTIONS: 1. CAM TIMER. Voltage to timer motor but time doesn t rotate. a. Check for a cam switch malfunction and replace timer. b. Check for incorrect cam setting and adjust.. FILTER. a. Filter is dirty. Replace element.. AIR DUCTS. a. Air ducts are obstructed. Remove the obstruction. 55 East Stop 18 Road Greenwood, Indiana Fax: Page:

23 4.8 MAINTENANCE AND INSPECTION SCHEDULE A. It is recommended that maintenance and inspection be done on a scheduled basis. Maintenance requirements will naturally vary widely for each installation and specific operating conditions. It is suggested that a complete inspection be performed with necessary maintenance at the end of the first month, the first three months and the first six months. These inspections will be indicative of how often future maintenance will be necessary. B. EVERY MONTH. 1. Inspect air filters. Clean or replace as required. Replace if cartridge is broken. The time interval for inspection should be shortened if experience indicates as required.. Check system for air leaks or flow obstructions and correct as required. C. EVERY MONTHS. 1. Check heater amperage (see Specification sheet).. Check motor amperage (see Specification sheet).. Check all electrical connections to make sure that they have not become loose, especially those connections at contractors, motor starters, and heater elements. D. ONCE EVERY YEAR. 1. Check solenoid valve operation and operation of valve. E. EVERY YEARS OR AS NEEDED. 1. Remove top cover of dryer and replace desiccant. Use high temperature silicon caulking to reseal the cover. See specification sheet for amount of desiccant. 55 East Stop 18 Road Greenwood, Indiana Fax: Page:

24 Note: This page intentionally left blank. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 4

25 5.0 RELATED DRAWINGS 5.1 TD-15 PHYSICAL (115/1/60) 5. TD-15 PHYSICAL WITH 60# HOPPER 5. TD-15 ELECTRICAL (115/1/60) 5.4 TD-5 PHYSICAL (0/V/60) 5.5 TD-5 PHYSICAL (460/1/60) 5.6 TD-5 ELECTRICAL (0/1/60) 5.7 TD-5 ELECTRICAL (460/1/60) 5.8 TD-5 0V WITH 100# HOPPER ON STAND 5.9 TD-5 0V PHYSICAL WITH STAND 5.10 TD-5 460V WITH 100# HOPPER PHYSICAL 5.11 TD-50 PHYSICAL 5.1 TD-50 0V PHYSICAL 5.1 TD V PHYSICAL 5.14 TD-50 PHYSICAL WITH 00# HOPPER (460V) 5.15 TD-50 ELECTRICAL 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 5

26 5.1 TD-15 PHYSICAL (115V/1/60) FILTER ELEMENT, P/N RIGHT BED LEFT BED PERFORATED SOLENOID COVER SOLENOID (SOL) LOCATED UNDER COVER 1 ITEM DESCRIPTION 1 BODY ASSEMBLY MOUNTING PLATE, PROCESS HEATER ' FLEX HOSE, NEOPRENE, " I.D. 4 HOSE CLAMP, " I.D. 5 CONTROLS 6 GASKET, DESICCANT BED 7 SCREEN, DESICCANT RETAINER 8 VALVE ASSEMBLY 9 BUSHING, HEYCO # FILTER ASSEMBLY, 5 1/4" DIA 11 0# DESICCANT, 1X MOLECULAR SIEVE(10# PER BED) 1 STRAIN RELIEF 1/" 1 BLOWER INLET DUCT, ", FLANGED 14 INSULATION, DESICCANT CHAMBER 15 BLOWER MOTOR ASSEMBLY 16 FILTER BAND, 5 1/4" 17 HEATER ELEMENT, 500W 0V 18 HEATER ELEMENT, 1600W 0V 19 BLOWER RESTRICTOR PLATE CAUTION DISCONNECT POWER BEFORE SERVICING T/C, THERMOCOUPLE DANGER HIGH VOLTAGE VOLTS CAUTION Additional bracing required in this area to support unit. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 6

27 5. TD-15 PHYSICAL WITH 60# HOPPER 1 DANGER HIGH VOLTAGE 115 VOLTS ITEM DESCRIPTION 1 TD-15 Dryer HOPPER - 60# 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 7

28 A/M SET OFF ON AT ALM F TD SERIES MATERIAL DRYER 5. TD-15 ELECTRICAL (115V/1/60) TB 115V 1Ø 60HZ GRD L L1 1SSR SSR SSR 1T1 T1 T1 TOTAL CONNECTED LOAD: KVA: 1.9 AMPS 1.8 H H H 1HTR HTR HTR L.REG.HTR R.REG.HTR PROCESS HTR 500 WATT 500 WATT 1000 WATT 4. AMPS 4. AMPS 8.7 AMPS FU 1/A 1TS "OFF/ON" 1 1 MTR BLOWER MOTOR CAM 1 4 SOL VALVE SHIFT SOLENOID CAM 5 1 SSR LEFT BED REGEN. HEATER CONTROL CAM 6 SSR RIGHT BED REGEN. HEATER CONTROL TM CAM TIMER MOTOR THSA ALARM CONTACT 8 HOURS = 100% C N.O. PERCENT OF ROTATION (CLOSE ON HT) CAM 0% 10% 0% 0% 40% 50% 60% 70% 80% 90% 100% 1 N.O. N.C. N.O. N.C. N.O. N.C. 1% 1% 51% 71% CAM #4 NOT USED L1 L WHITE + RED - C N.O. T/C HOPPER INLET 7 SSR TEMPERATURE CONTROLLER PROCESS HEATER CONTROL NOTE: LAST WIRE # USED IS 7 INSTALL HEAT SINK PADS UNDER SOLID STATE RELAYS TB () KT (115V) 1SSR SSR SSR 1TS THSA CAM TIMER ASSEMBLY (TM) AND MOUNT CONTROL BOX 1 1/ X 15 X 5 1/ P/N SCALE: /8 SIDE VIEW 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 8

29 5.4 TD-5 PHYSICAL (0V/1/60) FILTER ELEMENT, P/N RIGHT BED LEFT BED PERFORATED SOLENOID COVER SOLENOID (SOL) LOCATED UNDER COVER 15 ITEM DESCRIPTION 1 BODY ASSEMBLY MOUNTING PLATE, PROCESS HEATER ' FLEX HOSE, NEOPRENE, " I.D. 4 HOSE CLAMP, " I.D. 5 CONTROLS 6 GASKET, DESICCANT BED 7 SCREEN, DESICCANT RETAINER 8 VALVE ASSEMBLY 9 BUSHING, HEYCO # FILTER ASSEMBLY, 5 1/4" DIA 11 0# DESICCANT, 1X MOLECULAR SIEVE(10# PER BED) 1 STRAIN RELIEF 1/" 1 BLOWER INLET DUCT, ", FLANGED 14 INSULATION, DESICCANT CHAMBER 15 BLOWER MOTOR ASSEMBLY 16 FILTER BAND, 5 1/4" 17 HEATER ELEMENT, 500W 0V 18 HEATER ELEMENT, 1600W 0V CAUTION DISCONNECT POWER BEFORE SERVICING T/C, THERMOCOUPLE DANGER HIGH VOLTAGE 5 0 VOLTS CAUTION Additional bracing required in this area to support unit. 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 9

30 5.5 TD-5 PHYSICAL (460V/1/60) FILTER ELEMENT, P/N RIGHT BED LEFT BED PERFORATED SOLENOID COVER SOLENOID (SOL) LOCATED UNDER COVER 1 ITEM DESCRIPTION 1 BODY ASSEMBLY MOUNTING PLATE, PROCESS HEATER ' FLEX HOSE, NEOPRENE, " I.D. 4 HOSE CLAMP, " I.D. 5 CONTROLS 6 GASKET, DESICCANT BED 7 SCREEN, DESICCANT RETAINER 8 VALVE ASSEMBLY 9 BUSHING, HEYCO # FILTER ASSEMBLY, 5 1/4" DIA 11 0# DESICCANT, 1X MOLECULAR SIEVE(10# PER BED) 1 STRAIN RELIEF 1/" 1 BLOWER INLET DUCT, ", FLANGED 14 INSULATION, DESICCANT CHAMBER 15 BLOWER RESTRICTOR PLATE 16 FILTER BAND, 5 1/4" 17 HEATER ELEMENT, 500W 0V 18 HEATER ELEMENT, 1600W 0V 19 BLOWER RESTRICTOR PLATE.5 9 CAUTION DISCONNECT POWER BEFORE SERVICING T/C, THERMOCOUPLE DANGER HIGH VOLTAGE VOLTS East Stop 18 Road Greenwood, Indiana Fax: Page: 0

31 SET A/M OFF ON AT ALM F TD SERIES MATERIAL DRYER 5.6 TD-5 ELECTRICAL (0V/1/60) TB 0V L 1Ø 60HZ GRD L1 H1 H H H4 1CON CON CON 1T1 T1 T1 TOTAL CONNECTED LOAD: TRANS 50VA 9.6 AMPS X1 115 VAC X H H H 1HTR HTR HTR L.REG.HTR R.REG.HTR PROCESS HTR 500 WATT 500 WATT 1600 WATT. AMPS. AMPS 7.0 AMPS KVA:. FU 1/A 1 1TS "OFF/ON" 1 MTR BLOWER MOTOR CAM 1 4 VALVE SHIFT SOLENOID CAM 5 1 CON LEFT BED REGEN. HEATER CONTROL CAM 6 RIGHT BED REGEN. HEATER CONTROL TM CAM TIMER MOTOR THSA ALARM CONTACT C N.O. (CLOSE ON HT) L1 L TEMPERATURE CONTROLLER WHITE + RED - T/C HOPPER INLET C N.O. 7 CON PROCESS HEATER CONTROL NOTE: LAST WIRE # USED IS 7 8 HOURS = 100% PERCENT OF ROTATION CAM 1 N.O. N.C. 0% 10% 0% 0% 40% 50% 60% 70% 80% 90% 100% N.O. N.C. 1% 1% 51% 71% CAM #4 NOT USED TRANS FU 50 VA TB () KT INSTALL HEAT SINK PADS (115V) UNDER SOLID STATE RELAYS 1SSR SSR SSR 1TS THSA CAM TIMER ASSEMBLY (TM) AND MOUNT CONTROL BOX 1 1/ X 15 X 5 1/ P/N SCALE: /8 SIDE VIEW 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 1

32 A/M SET OFF ON AT ALM F TD SERIES MATERIAL DRYER 5.7 TD-5 ELECTRICAL (460V/1/60) 460V 1fl 60HZ GRD TB L L1 H1 H H H4 1SSR SSR SSR 1T1 T1 T1 TRANS TOTAL CONNECTED LOAD: KVA: 50VA X1 4.8 AMPS. 115 VAC X H H H 1HTR HTR HTR L.REG.HTR R.REG.HTR PROCESS HTR 500 WATT 500 WATT 1600 WATT 1.1 AMPS 1.1 AMPS.5 AMPS FU 1/A 1TS "OFF/ON" 1 1 MTR BLOWER MOTOR CAM 1 4 SOL VALVE SHIFT SOLENOID CAM 5 1 SSR LEFT BED REGEN. HEATER CONTROL CAM 6 SSR RIGHT BED REGEN. HEATER CONTROL TM CAM TIMER MOTOR 8 HOURS = 100% THSA ALARM CONTACT PERCENT OF ROTATION C N.O. CAM 0% 10% 0% 0% 40% 50% 60% 70% 80% 90% 100% (CLOSE ON HT) 1 N.O. N.C. N.O. N.C. 1% 1% L1 L TEMPERATURE CONTROLLER N.O. N.C. 51% CAM #4 NOT USED 71% WHITE + RED - C N.O. T/C HOPPER INLET 7 SSR PROCESS HEATER CONTROL NOTE: LAST WIRE # USED IS 7 TRANS FU 50 VA INSTALL HEAT SINK PADS UNDER SOLID STATE RELAYS 1SSR SSR SSR TB () KT (115V) 1TS THSA CAM TIMER ASSEMBLY (TM) AND MOUNT CONTROL BOX 1 1/ X 15 X 5 1/ P/N SCALE: /8 SIDE VIEW NOTES: SSR s MUST BE P/N (REV A), RATED FOR 480 VAC REFER TO TEMPERATURE CONTROLLER BULLETIN FOR COMPLETE OPERATING INFORMATION. 55 East Stop 18 Road Greenwood, Indiana Fax: Page:

33 5.8 TD-5 0V WITH 100# HOPPER ON STAND ISOMETRIC VIEW 55 East Stop 18 Road Greenwood, Indiana Fax: Page:

34 5.9 TD-5 0V PHYSICAL WITH STAND DANGER HIGH VOLTAGE 0 VOLTS 5 4 (SEE DETAIL A) RIGHT BED 1.49 LEFT BED East Stop 18 Road Greenwood, Indiana Fax: Page: 4

35 5.10 TD V WITH 100# HOPPER PHYSICAL 1 DANGER HIGH VOLTAGE 460 VOLTS ITEM DESCRIPTION 1 TD-5 Dryer 460V HOPPER # 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 5

36 5.11 TD-50 PHYSICAL DANGER HIGH VOLTAGE 0 VOLTS ITEM DESCRIPTION 1 TD-50 Dryer 0V HOPPER - 00# 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 6

37 5.1 TD-50 0 V PHYSICAL FILTER ELEMENT, P/N OUT IN RIGHT BED 5.56 LEFT BED PERFORATED SOLENOID COVER SOLENOID (SOL) LOCATED UNDER COVER DIRECTION OF ROTATION CAUTION DISCONNECT POWER BEFORE SERVICING ON HOPPER INLET INSTALL IN 1/8" COUPLING TC, THERMOCOUPLE, DANGER HIGH VOLTAGE 0 VOLTS 1 4 ITEM DESCRIPTION 1 DRYER BODY, TD-50 CONN 6FT CABLE 40# DESICCANT, 1X(0# PER BED) 4 INSULATION, DRYER BOX 5 CONTROLS, TD-50 DRYER 6 STRAIN RELIEF, 1/" 7 VALVE ASSY 8 BUSHING GASKET, DESICCANT BED 10 SCREEN, DESICCANT RETAINER 11 FILTER ASSEMBLY, 5 1/4" DIA 1 CONN.,QC 4 PIN MALE W/1" PIGTAIL 1 FILTER MOUNT BAND, 5 1/4" DIA 14 ADAPTER, 1 1/4" PIPE TO " TUBE 15 HOSE CLAMP, " 16 FT FLEX HOSE, SILICONE, "I.D. 17 MOUNT PLATE, PRO. HTR. ELEMENTS 18 PIPE PLUG, 1 1/4" 19 REGEN HEATER ELEMENT, 500W, 0V 0 PROCESS HEATER ELEMENT, 00W, 0V 1 BLOWER ASSY, 0V SOLENOID 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 7

38 5.1 TD-50 PHYSICAL 460 V FILTER ELEMENT, P/N OUT IN RIGHT BED LEFT BED PERFORATED SOLENOID COVER ITEM DESCRIPTION 1 DRYER BODY, S/M & WELD, TD-50 CONN.,QC 4 PIN FEMALE W/6FT CABLE 40# DESICCANT, 1X(0# PER BED) 4 INSULATION, DRYER BOX 5 CONTROLS, TD-50 DRYER 6 STRAIN RELIEF, 1/" 7 VALVE ASSY 8 BUSHING, HEYCO #107 9 GASKET, DESICCANT BED 10 SCREEN, DESICCANT RETAINER 11 FILTER ASSEMBLY, 5 1/4" DIA 1 CONN.,QC 4 PIN MALE W/1" PIGTAIL, 8A,600V 1 FILTER MOUNT BAND, 5 1/4" DIA 14 ADAPTER, 1 1/4" PIPE TO " TUBE 15 HOSE CLAMP, " 16 FT FLEX HOSE, SILICONE, "I.D. 17 MOUNT PLATE, PRO. HTR. ELEMENTS 18 PIPE PLUG, 1 1/4" 19 REGEN HEATER ELEMENT, 500W, 460V 0 PROCESS HEATER ELEMENT, 00W, 460V 1 BLOWER ASSY SOLENOID SOLENOID (SOL) LOCATED UNDER COVER DIRECTION OF ROTATION CAUTION DISCONNECT POWER BEFORE SERVICING ON HOPPER INLET INSTALL IN 1/8" COUPLING TC, THERMOCOUPLE, DANGER HIGH VOLTAGE 460 VOLTS East Stop 18 Road Greenwood, Indiana Fax: Page: 8

39 5.14 TD-50 PHYSICAL WITH 00# HOPPER (460V) 55.5 DANGER HIGH VOLTAGE 460 VOLTS ITEM DESCRIPTION 1 TD-50 Dryer 460V HOPPER - 00# 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 9

40 A/M SET OFF ON AT ALM F TD SERIES MATERIAL DRYER 5.15 TD-50 ELECTRICAL 0V fl 60HZ TB L L L1 GRD H1 H H H4 1OL 1MS 1MS 1MS T1 1SSR SSR SSR H T1 H H TOTAL CONNECTED LOAD: 8.0 AMPS 1T1 1T 1T H H 4T1 H KVA: 11. X1 115 VAC X MTR 1 1HTR L.REG.HTR 1000 WATT 4.4 AMPS HTR R.REG.HTR 1000 WATT 4.4 AMPS HTR PROCESS HTR 4600 WATT 0.0 AMPS BLOWER MOTOR /4 HP, TEFC.6 FLA FU 1/A 1TS "OFF/ON" 1 1OL 4 1MS BLOWER MOTOR STARTER 1MSA 5 CAM 1 6 VALVE SHIFT SOLENOID 5 CAM 7 1 SSR LEFT BED REGEN. HEATER CONTROL 5 CAM 8 RIGHT BED REGEN. HEATER CONTROL 5 TM CAM TIMER MOTOR THSA ALARM CONTACT C N.O. (CLOSE ON HT) 5 L1 L TEMPERATURE CONTROLLER WHITE + RED - 5 C N.O. NOTE: LAST WIRE # USED IS 9 T/C HOPPER INLET 9 8 HOURS = 100% PERCENT OF ROTATION SSR PROCESS HEATER CONTROL NOTE: REFER TO TEMPERATURE CONTROLLER BULLETIN FOR COMPLETE OPERATING INFORMATION. CAM 0% 10% 0% 0% 40% 50% 60% 70% 80% 90% 100% 1 N.O. N.C. 1% N.O. N.C. 1% N.O. N.C. 51% 71% CAM #4 NOT USED TRANS FU 50 VA 1 MS TB (5) KT (115V) INSTALL HEAT SINK PADS UNDER SOLID STATE RELAYS 1SSR SSR SSR 1TS THSA CAM TIMER ASSEMBLY (TM) AND MOUNT CONTROL BOX 1 1/ X 15 X 5 1/ P/N SCALE: /8 SIDE VIEW 55 East Stop 18 Road Greenwood, Indiana Fax: Page: 40

41 END 1998 RE 1 11/98

42

HB CDA SERIES WITH TEMPERATURE SETBACK

HB CDA SERIES WITH TEMPERATURE SETBACK HB CDA SERIES WITH TEMPERATURE SETBACK 2013 NOVATEC, Inc. All Rights Reserved Document: HB CDA IM 7-24-2013 NOTES: Please record the following information, which is specific to this piece of equipment,

More information

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 14 DEC NOVATEC, Inc All Rights Reserved

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 14 DEC NOVATEC, Inc All Rights Reserved POD Silo Dehumidifier Series with Logo! TM PLC POD-150 NOVATEC, Inc. 2016 All Rights Reserved DOCUMENT: 2012 Novatec, Inc. All Rights Reserved Page 2 VL-VLP IM 10-24-2012 NOTES: Please record the following

More information

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com

More information

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com

More information

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com

More information

NDB Dryers with NovaTouch PLC Control

NDB Dryers with NovaTouch PLC Control NDB Dryers with NovaTouch PLC Control NOVATEC, Inc. 2016 All Rights Reserved DOCUMENT: NDB_NovaTouch PLC IM 19 JAN 2012 NOVATEC, Inc. All Rights Reserved Page 2 VL-VLP IM 10-24-2012 NOTES: Please record

More information

DRI-AIR INDUSTRIES, INC. AHM & HPHM 2-4 HOPPER MOUNT DRYERS OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. AHM & HPHM 2-4 HOPPER MOUNT DRYERS OPERATING MANUAL AHM & HPHM 24 HOPPER MOUNT DRYERS OPERATING MANUAL OPERATING MANUAL AHM/HPHM 24 HOPPER MOUNT DRYERS Page 1 DRIAIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 060881020 Tel. (860) 6275110

More information

Temptek Auxiliary Equipment

Temptek Auxiliary Equipment Temptek Auxiliary Equipment Mold Temperature Controllers - Water Units VT-275-LX VT Series Mold Temperature Controllers are used to process temperature control to 250 F. These units use an incoloy heater

More information

P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T

P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T Drying systems for processors in the plastics, food, chemical, pharmaceutical, printing, and machine tool industries Resin Crystallizers

More information

NDB-15 through NDB-50

NDB-15 through NDB-50 NDB-15 through NDB-50 NDB-25 NOVATEC, Inc. 2018 All Rights Reserved DOCUMENT: NDB-15-50 IM 28 FEB 2018 Page 1 of 2 NOTES: Please record the following information, which is specific to this piece of equipment,

More information

DRI-AIR INDUSTRIES, INC. HA750B B HOT AIR DRYER OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. HA750B B HOT AIR DRYER OPERATING MANUAL HA750B - 1500B HOT AIR DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com

More information

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 INSTALLATION-OPERATION-MAINTENANCE CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 TEFC 3 phase motor Outlet duct Fan wheel housing Inlet duct connection After filter transition Optional after filter unit

More information

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS GENERAL INDEECO Industrial Control Panels are designed to provide years of trouble free operation if properly

More information

PROTEK DRYER CONTROLS

PROTEK DRYER CONTROLS PROTEK DRYER CONTROLS INSTRUCTION MANUAL IB201501. 1885 Thunderbird Street, Troy, Mi. 48084 Phone 248.362.0960 FAX 248.362.5270 www.thoresonmccosh.com sales@thoresonmccosh.com FORWARD Installation, Operation

More information

MODEL MW200 MODEL MW600 AIR DRYER

MODEL MW200 MODEL MW600 AIR DRYER OPERATING MANUAL MODEL MW200 MODEL MW600 AIR DRYER Mail Address: 226A Commerce St. Tel: 303-465-3063 Broomfield, CO 80020 Fax: 303-465-9294 TABLE OF CONTENTS 1.0 GENERAL...3 2.0 SPECIFICATIONS...3 3.0

More information

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 15 MAY NOVATEC, Inc All Rights Reserved.

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 15 MAY NOVATEC, Inc All Rights Reserved. POD Silo Dehumidifier Series with Logo! TM PLC POD-150 NOVATEC, Inc. 2017 All Rights Reserved DOCUMENT: POD IM 15 MAY 2017 Page 1 of 2 NOTES: Please record the following information, which is specific

More information

D Carousel Dryer - DC

D Carousel Dryer - DC www.conairnet.com USER GUIDE UGD022/0304 D Carousel Dryer - DC Models 15, 25, 50, 75, and 100 with DC Controls INTRODUCTION Purpose of the User Guide How the guide is organized Your responsibilities as

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

D Carousel Dryer - DC-1

D Carousel Dryer - DC-1 www.conairnet.com USER GUIDE UGD024/0304 D Carousel Dryer - DC-1 Models 15, 25, 50, 75, and 100 with DC-1 Controls INTRODUCTION Purpose of the User Guide How the guide is organized Your responsibilities

More information

Carousel Plus Dryer. W Series Models 15, 25, 50, 75 and 100 with DC-1 Controls

Carousel Plus Dryer. W Series Models 15, 25, 50, 75 and 100 with DC-1 Controls USER GUIDE UGD032-0407 www.conairnet.com Carousel Plus Dryer W Series Models 15, 25, 50, 75 and 100 with DC-1 Controls INTRODUCTION Purpose of the User Guide How the guide is organized Using the Carousel

More information

ATKINSON DYNAMICS SPEAKERS

ATKINSON DYNAMICS SPEAKERS ATKINSON DYNAMICS SPEAKERS INSTALLATION AND SERVICE INSTRUCTIONS FOR MODELS AD-SF-25, AD-SS-25, AD-SO-25, AD-SV-25, AD-TB-25 Atkinson Dynamics 2645 Federal Signal Drive University Park, IL 60484-3167 (708)

More information

SC Carousel Dryer. Models 7.5 and 15, with PLC controls. Installation. Maintenance. Operation. Troubleshooting

SC Carousel Dryer. Models 7.5 and 15, with PLC controls. Installation. Maintenance. Operation. Troubleshooting SC Carousel Dryer Models 7.5 and 15, with PLC controls Installation Maintenance Operation Troubleshooting 180 180 Instant Access Parts and Service (800) 458-1960 (814) 437-6861 www.conairnet.com The Conair

More information

DRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL

DRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL HOPPER BANK OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com e-mail: sales@dri-air.com

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT TABLE OF CONTENTS Description Page # Introduction 3 Customer Support 3 Model Number Nomenclature 4 Control Panel 5 Display Panel

More information

DRI-AIR INDUSTRIES, INC. APD 1-9 HPD 1-9 OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. APD 1-9 HPD 1-9 OPERATING MANUAL APD 1-9 HPD 1-9 OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Page 2 Tel. (860) 627-5110 FAX (860) 623-4477 Internet e-mail: http://www.dri-air.com

More information

"ESDDR" Series Electric Humidifier

ESDDR Series Electric Humidifier ESDDR-1 Deionized, Demineralized, or Reverse Osmosis Water "ESDDR" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is deionized,

More information

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CRYOGENIC EXPERTS, INC. World Wide Web   Toll Free FOR CEXI Phone (805) Facsimile (805) CRYOGENIC EXPERTS, INC. World Wide Web http://www.cexi.com E-mail cexi@cexi.com Toll Free 1-800-FOR CEXI Phone (805) 981-4500 Facsimile (805) 981-4501 I. Installation Instructions Installation And Operating

More information

Operation and Maintenance Manual. Dryer Package. Model Number: Job Number: Date Shipped: Date Started Up: Electrical: 120 V single phase - AC

Operation and Maintenance Manual. Dryer Package. Model Number: Job Number: Date Shipped: Date Started Up: Electrical: 120 V single phase - AC Operation and Maintenance Manual Dryer Package Model Number: Job Number: Date Shipped: Date Started Up: Electrical: 120 V single phase - AC w w w. a m i c o. c o m Introduction For further technical assistance,

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE - SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN VC3ED ML-137013 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly

More information

P4200PM / P5000PM Remote Air Dryer User s Guide

P4200PM / P5000PM Remote Air Dryer User s Guide P4200PM / P5000PM Remote Air Dryer User s Guide 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P4200PM / P5000PM Air Dryer! We here at PUREGAS are very proud of our products

More information

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER INSTRUCTIONS FOR TAL SERIES VACUUM HOR LOADER TAL-15U 150 LBS PER HOUR MAGNETIC LEVEL SWITCH TAL-3U-E 450 LBS PER HOUR SIGHT GLASS WITH PROXIMITY LEVEL SWITCH Proportional Dual Feed Valve Available TAL-6U

More information

Quality Components as a basis for Quality Equipment

Quality Components as a basis for Quality Equipment Above & Beyond Regenerative Type Compressed Air Dryers SPS - Heatless Regenerative Dryers SPEH - External Heated Regenerative Dryers SPBS - Heated Blower Purge Regenerative Dryers Quality Components as

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

Equipment Designed for Industrial Applications

Equipment Designed for Industrial Applications Equipment Designed for Industrial Applications Industrial equipment with moving components requires maintenance. As a manufacturer of industrial equipment we strive to produce a product that operates as

More information

Bench-Top Vacuum Oven with 28 segments programmable controller

Bench-Top Vacuum Oven with 28 segments programmable controller Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully

More information

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESB Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Dual Column Dehydrating Breather Manual

Dual Column Dehydrating Breather Manual Dual Column Dehydrating Breather Manual DCB-MANUAL 1.6 Read and understand this manual prior to operating or servicing the products. SPX Transformer Solutions, Inc., Service & Components Division U.S.

More information

Dual Tower Heat Reactivated Desiccant Air Dryer

Dual Tower Heat Reactivated Desiccant Air Dryer Dual Tower Heat Reactivated Desiccant Air Dryer idhpe Dryer idbpe Dryer Eliminate Water from Your Compressed Air System Moisture in compressed air is damaging. Without proper treatment, this vital energy

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

PORT700CF Portable Fume Collector

PORT700CF Portable Fume Collector 11975 Portland Ave. S. Suite 104 Burnsville, MN 55337 Phone: 952-894-6637 Fax: 952-894-0750 Email: info@ventaire.com Website: www.ventaire.com PRODUCT GUIDE FOR PORT700CF Portable Fume Collector REV:110314

More information

M Series Fan Filter Units

M Series Fan Filter Units M Series Fan Filter Units Product Specifications... 2 Safety Instructions... 3 Receiving and Unpacking... 3 Pre-Installation Instructions... 3-4 Installation Instructions... 4 Electrical Installation Instructions...

More information

690 and Power Fishing Systems

690 and Power Fishing Systems INSTRUCTION MANUAL 690 and 690-22 Power Fishing Systems Includes Serial Number AAR 3800 and higher (120 volt model) Includes Serial Number AAT 00500 and higher (220 volt model) Read and understand all

More information

CLe-series Dishwashers

CLe-series Dishwashers CLe-series Dishwashers Blower-dryer electric (CLe SERIES) ML-138211 ML-138212 ML-138213 ML-138214 electric (CLeR SERIES) ML-138325 ML-138326 ML-138327 ML-138328 STEAM (CLe SERIES) ML-138226 ML-138227 ML-138228

More information

Mineral Insulated Band Heater

Mineral Insulated Band Heater The MI band heater is a high-performance heater. Its performance and name are derived from exclusive mineral insulation a material with much higher thermal conductivity than mica and hard ceramic insulators

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

BLAST-IT-ALL BUMPER BLASTER

BLAST-IT-ALL BUMPER BLASTER LARRY HESS AND ASSOCIATES, INC 185 PIPER LANE / SALISBURY, NC 28147 PHONE: 1-800-535-2612 / FAX: 1-704-638-9311 WWW.BLAST-IT-ALL.COM BLAST-IT-ALL BUMPER BLASTER SUCTION BLAST CABINET NOTE: It is the responsibility

More information

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual VACUUM OVEN Model: VPX9-2 Installation and Operation Manual Sheldon Manufacturing, Inc. P.O. Box 627, 300 N 26 th Avenue, Cornelius, Oregon 97113 EMAIL: tech @ Shellab.com; www.shellab.com 1-800-322-4897

More information

VSA Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud

More information

Type 40HT Electrode Rebaking Ovens

Type 40HT Electrode Rebaking Ovens OPERATING INSTRUCTIONS Type 40HT Electrode Rebaking Ovens MODEL PART # DESCRIPTION (All 50-60 Cycles) TEMP RANGE** INSULATION CHAMBER SIZE CAPACITY WEIGHT & DIMENSIONS Type 40HT Series Model Type 40HT

More information

Series: MBC1-TC Mini Benchtop Temperature Controller

Series: MBC1-TC Mini Benchtop Temperature Controller User s Guide Series: MBC1-TC Mini Benchtop Temperature Controller Imagine Instruments LLC:: 4500 Williams Drive, Ste 212-318 :: Georgetown, TX 78633 :: p. 855.574.6243 e-mail: info@imagineinstruments.com

More information

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual MR Series Heatless Mini Regenerative Desiccant Dryer Operator s Manual Introduction Many years of trouble-free service can be expected from your Numatics regenerative dryer. Superior dew point depression

More information

Type 750HT Flux Rebaking Ovens

Type 750HT Flux Rebaking Ovens OPERATING INSTRUCTIONS Type 750HT Flux Rebaking Ovens MODEL PART # DESCRIPTION (All 50-60 Cycles) TEMP RANGE** INSULATION CHAMBER SIZE CAPACITY WEIGHT & DIMENSIONS Type 750HT Series Model 5 1201801 3/480V

More information

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE GASS Module Gas Analysis Sampling System User Manual PERMA PURE 8 Executive Drive Toms River, N.J. 08755 Phone: 800-337-3762 732-244-0010 Fax: 732-244-8140 e-mail: info@permapure.com Web Site: www.permapure.com

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS Installation & Operating Manual 3001806 03.02 USA CAN BESF Box Ventilator READ AND SAVE THESE INSTRUCTIONS 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731

More information

Safety, Operation and Maintenance Manual with Parts List

Safety, Operation and Maintenance Manual with Parts List Safety, Operation and Maintenance Manual with Parts List Important Information and Safety Instructions PLEASE READ BEFORE USE! 961130022-10/10-Rev1 TABLE OF CONTENTS Safety Instructions...2 Grounding Instructions...4

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

Installation Electric Dryers Instructions 01

Installation Electric Dryers Instructions 01 Installation Electric Dryers Instructions 01 Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com This is the safety alert symbol. This symbol alerts you to potential

More information

INSTALLATIONN GUIDE & OPERATION MANUAL

INSTALLATIONN GUIDE & OPERATION MANUAL INSTALLATION INSTRUCTIONS ECO # 1569 REVISION #0006 FCS SERIES MODEL 5025, 5045,7525 & 7545 INSTALLATION INSTRUCTIONS BY: DATE: 01/23/2013 INSTALLATIONN GUIDE & OPERATION MANUAL MOTOR OPERATOR (V3.02 Controls)

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

Quest PowerDry 4800D Pro E:

Quest PowerDry 4800D Pro E: Quest DRY PowerDry 150 4800D Pro E Read and Save These Instructions This manual is provided to acquaint you with the desiccant dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL

VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab

More information

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL ECONOMY VACUUM OVEN MODEL: 1407, 1407-2, 1408, & 1408-2 INSTALLATION AND INSTRUCTION MANUAL Sheldon Manufacturing Inc. P.O. Box 627, Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab

More information

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS FL--D 595 Heisley Road Mentor, OH 440-8 Rev. 0 (5/) Page of INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS 000-CH-SS-D 000-CH-AL-D 000-CH-SS-SPLIT-D 000-CH-AL-SPLIT-D 000-CH-SS-SPLIT-D0

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS 9 Heisley Road Mentor, OH 0- Rev. (6/0) Page of INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS ROFWB-Q COFWUAB-Q

More information

SAFETY, OPERATION AND MAINTENANCE MANUAL. DRY VACUUM CLEANER This unit is intended for commercial use. SAVE THESE INSTRUCTIONS

SAFETY, OPERATION AND MAINTENANCE MANUAL. DRY VACUUM CLEANER This unit is intended for commercial use. SAVE THESE INSTRUCTIONS SAFETY, OPERATION AND MAINTENANCE MANUAL W/ PARTS LIST DRY VACUUM CLEANER This unit is intended for commercial use. READ & FOLLOW ALL INSTRUCTIONS,WARNINGS & CAUTIONS BEFORE USING THIS VACUUM This vacuum

More information

Pentz EF5 Installation Guide

Pentz EF5 Installation Guide Pentz EF5 Installation Guide Clear Vue Cyclones 145 Nix Road Liberty, SC 29657 888-299-0221 www.clearvuecyclones.com Disclaimers & Warnings WARNING: All persons, by purchasing a motorized dust collection

More information

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS TEMPERATURE CONTROLLERS - WATER UNITS VT Series temperature controllers are used for process temperature control to 250 F. These units use an incoloy heater and centrifugal

More information

Owner s Manual Phoenix 4800 E Industrial Desiccant Dehumidifier

Owner s Manual Phoenix 4800 E Industrial Desiccant Dehumidifier 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 4800 E Industrial Desiccant Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions Congratulations on your purchase

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S File Literature Number 1144-01-1 Installation Operation & Maintenance Manual CONTINUOUS REFRIGERANT DEHYDRATOR Model: CD-120 For use with Refrigerants R-11, R-123, R-12, R-22, R-134a

More information

Owners Manual Refrigerated Air Dryer MHT SERIES

Owners Manual Refrigerated Air Dryer MHT SERIES Owners Manual Refrigerated Air Dryer MHT SERIES IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS IN- FORMATION ABOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILAR WITH THE PROPER INSTALLATION

More information

VACUUM LOADERS GSL Series

VACUUM LOADERS GSL Series VACUUM LOADERS GSL Series Models: GSL-12 & GSL-12-MM GSL-19 & GSL-19-MM Patent # 8,753,432 and 8,070,844 GSL-19 GSL-19 Tilted GSL-19-MM Machine Mount NOVATEC, INC. 2016 All Rights Reserved Instruction

More information

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

28 1/2* 72.4 cm. (*28 1/2  to include hinges.) 41 3/4 106 cm. 27 68.6 cm. 28 1/2* 72.4 cm. (includes hinges.) 28 1/2* 41 3/4 106 cm Commercial Single Load Dryers 28 1/2"* 72.4 cm PRODUCT DIMENSIONS (*28 1/2 " to include hinges.) 28 1/2"* 72.4 cm (*28 1/2 " to include hinges.) Models MDE/MDG21PD MDE/MDG21PS MDE/MDG21PR MDE/MDG21PN 43

More information

NovaWheel. Desiccant Wheel Dryer. NovaWheel dryers take a proven drying technology to a new level of excellence reducing your energy costs

NovaWheel. Desiccant Wheel Dryer. NovaWheel dryers take a proven drying technology to a new level of excellence reducing your energy costs NovaWheel Desiccant Wheel Dryer NW Series: 100-5000 lb./hr.( 36-2272 kg/hr.) NovaWheel dryers take a proven drying technology to a new level of excellence reducing your energy costs D R Y Replace energy-hog

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units

More information

MARTIN Insertable Dust Collector

MARTIN Insertable Dust Collector MARTIN Insertable Dust Collector Go to MARTIN Insertable Dust Collector web page Operator s Manual M3416 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION OF

More information

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

Owner s Manual Phoenix 1200 Desiccant Dehumidifier PO Box 8680 Madison, WI 53708 Owner s Manual Phoenix 1200 Desiccant Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 1200 Portable Desiccant Dehumidifier

More information

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081305-01 Date 10/08 Introduction IOD150,IOD200,IOD250

More information

NovaDrier MEMBRANE DRYER for Plastics

NovaDrier MEMBRANE DRYER for Plastics NovaDrier MEMBRANE DRYER for Plastics MODELS: ND-7, ND-25, ND-50, ND-75, ND-100, ND-150, ND-200 U.S. Patent No. US 6,584,701 B1 NOTE: See important information about air supply on next page. NOVATEC, Inc.

More information

VACUUM LOADERS GSL Series

VACUUM LOADERS GSL Series VACUUM LOADERS GSL Series Models: GSL-19 & GSL-19-MM (Patent Pending) GSL-19 GSL-19 Tilted GSL-19-MM Machine Mount Instruction Manual GSL 9-12-12 IM Doc. GSL IM 8-21-12 Page 1 NOTES: Please record the

More information

Fluid Cooler Fan and Pump control panel

Fluid Cooler Fan and Pump control panel user manual Fluid Cooler Fan and Pump control panel INSTALLATION - OPERATION - MAINTENANCE Z02819_A M03-171B ISSUED 07/2014 0/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR OR SERVICING THIS

More information

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DF400/DF600. Construction Heaters. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction

More information

CM Carousel Dryer. Standard Models CM100, 150, 200, 300 and 400. Installation. Maintenance. Operation. Troubleshooting

CM Carousel Dryer. Standard Models CM100, 150, 200, 300 and 400. Installation. Maintenance. Operation. Troubleshooting Power Running Alarm/Fault Start Dryer Stop Dryer Standard Models CM00, 50, 00, 00 and 400 CM Carousel Dryer Installation Maintenance Operation CM Carousel Dryer Troubleshooting CM-00 Set Temperature Dryer

More information

TC-150 CONVEYORIZED OVEN. OPERATION AND MAINTAINANCE MANUAL Ovens with Omron PLC and Touchscreen

TC-150 CONVEYORIZED OVEN. OPERATION AND MAINTAINANCE MANUAL Ovens with Omron PLC and Touchscreen TC-150 CONVEYORIZED OVEN OPERATION AND MAINTAINANCE MANUAL Ovens with Omron PLC and Touchscreen Rev F CIRCUIT AUTOMATION 5292 System Drive Huntington Beach, CA 92649 U.S.A. Copyright CAI 2014 Tel 714.763.4180

More information

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through

More information

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074) HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS #116075 (TED1-8074) 2004 IMS Co. October, 2004 IMS Company 10373 Stafford Road Chagrin Falls, OH 44023-5296 Telephone: (440) 543-1615 Fax: (440)

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER 1 Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER FOR YOUR SAFETY This manual supplies information on the application,

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER Rev. 1 (1/16) Page 1 of 12 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER REVOLUTION FOODS MODEL CO151027 Rev. 1 (1/16) Page 2 of 12 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION

More information

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -

More information