EQUIPMENT CLEANING Indira Pindi Watershed Monitoring September 20, 2017

Size: px
Start display at page:

Download "EQUIPMENT CLEANING Indira Pindi Watershed Monitoring September 20, 2017"

Transcription

1 EQUIPMENT CLEANING Indira Pindi Watershed Monitoring September 20, 2017

2 Overview Why cleanliness is next to godliness Cleaning materials & containers General cleaning requirements Documentation Field cleaning GW, SW, & sediment equipment Contamination

3 Why is cleaning important? To remove any remaining analytes or substances that could interfere with obtaining quality data

4 Why is cleaning important? to preclude your data from being qualified due to detections in associated field collected blanks

5 Cleaning Materials Analyte-free water Free of analytes of interest Uses: Final cleaning rinse Blanks Detergent Liqui-Nox, Luminox or other non-phosphate detergent, diluted Luminox is required for organics (sucralose, pharmaceuticals, pesticides)

6 Cleaning Materials Acid Rinses (metals, inorganic analytes) Reagent-grade hydrochloric acid 10% HCL Use for all non-stainless steel equipment Dispose of acids properly If Luminox is not available and organics are collected, must add rinse with pesticide grade isopropanol.

7 Handling and Containers for Cleaning Solutions Avoid contamination Use HDPE or PP containers Keep them clean, with protectors over spigots Clearly label bottles as DI water, tap water, or detergent

8 Handling Containers for Cleaning Solutions Label analyte-free water containers with date filled If logistics permit, empty all DI containers daily. At a minimum: Weekly Do not store DI water in large container for more than one week Daily Empty and refill small containers, such as squirt bottles

9 All cleaning should be done as soon as possible Lab cleaning is preferred Do not let dirty equipment sit overnight

10 General Cleaning Requirements 1. Rinse with hot tap water 2. Soak in hot soapy tap water 3. Scrub with brush to remove particulates 4. Rinse with hot tap water 5. Rinse with hydrochloric acid (except stainless steel) 6. Rinse with analyte-free water 7. Air dry, wrap and store properly

11 Cleaning Documentation Keep a cleaning log, Fig. 39 For ALL cleaning, field and lab Required Info. Specific piece(s) of equipment Date (& time if field cleaned) Location (lab or field) Procedure Name of person performing cleaning

12 Field Cleaning Materials Tap water DI water Tub or container for soaking Scrub brush Luminox solution

13 GW Field Cleaning Protect equipment use plastic ground cover Clean with soapy water and brush Rinse well with DI water

14 GW Cleaning: Pumps Purging Only Flush with Tap/DI water before and after purging Scrub exterior of pump/tubing that may contact formation water Purging & Sampling Disassemble (if able) and decontaminate If pump cannot be disassembled, then follow these next steps:

15 GW Cleaning: Pumps 1. Fill dedicated container with sudsy Tap water 2. Pump 3 volumes through tubing 3. Use sudsy water to clean outside 4. Pump DI water through tubing 5. Protect clean pump

16 New Tubing GW Cleaning: Tubing If certified clean ok If not, soak in hot soapy water, rinse with hot tap water and then DI water Wrap/store in clean container (wrap ends with foil, seal in plastic bag) Re-used Tubing In-house cleaning Follow general cleaning procedure

17 Surface Water Cleaning: Van Dorn 1. Half fill Van Dorn with tap water and Luminox 2. Shake well, brush 3. Drain some through spigot 4. Dump soapy water

18 Surface Water Cleaning: Van Dorn 5. Rinse Van Dorn thoroughly with tap water 6. Rinse with HCI acid 7. Rinse with DI water 8. Rinse through spigot 9. Air dry 10. Store in a clean container or bag

19 Sediment Cleaning (Ekman, P. Ponar, corer, HDPE scoops & forceps) 1. Rinse Pour tap water over the equipment into dedicated tub or cooler. 2. Soak & Scrub with brush. Use dedicated pump spray bottle of Luminox/DI water to spray inside and out

20 Sediment Cleaning (Ekman, P. Ponar, corer, HDPE scoops & forceps) 3. Dispose soapy water, rinse tub 4. Pour 5 gal. tap water over equipment into tub 5. Dunk 4-5 times, working jaws 6. Rinse tub 7. Pour 5 gal. DI water over equipment into tub 8. Dunk 4-5 times, working jaws 9. Store in clean bag or container Reminder: you must clean between sediment sampling sites, both at small lakes, and all sites on a large lake

21 Heavily Contaminated Equipment If sampling site is heavily contaminated, contact Tallahassee WMS For example: while purging a well, samplers may see or smell obvious contamination (not including Sulfur) If equipment comes in contact with contaminated site, use DEP SOP FC 1120, document contamination, & contact Tallahassee WMS

22 QUESTIONS? Do you want to clean the equipment or should I do it?

Laboratory Glassware Cleaning and Storage

Laboratory Glassware Cleaning and Storage General 07_02_01.004 Dates Active: March 14 th, 2018 - Present Author: Victoria Wickham Laboratory Glassware Cleaning and Storage 1 INTRODUCTION The proper care and cleaning of laboratory glassware is

More information

Title: Glassware Cleaning Copy No: ## SOP No.: 3.02/2.6/S Effective Date: June 18, 2013 Location: ### Glassware Cleaning

Title: Glassware Cleaning Copy No: ## SOP No.: 3.02/2.6/S Effective Date: June 18, 2013 Location: ### Glassware Cleaning 1. Introduction Glassware Cleaning QSM Approval: All glassware used in the analysis of toxic organic compounds at the trace and ultra-trace level must be scrupulously cleaned as soon as possible after

More information

STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES

STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES 1.0 INTRODUCTION STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES This Standard Operating Procedure (SOP) was prepared to direct field personnel in the methods for decontamination of field

More information

HAVE A SAMPLING AND ANALYSIS PLAN (SAP)

HAVE A SAMPLING AND ANALYSIS PLAN (SAP) THE HOW TO OF SAMPLING, TRANSPORTING, AND DELIVERY HAVE A SAMPLING AND ANALYSIS PLAN (SAP) INCLUDE SAMPLING LOCATIONS NUMBERS AND TYPES OF SAMPLES TO BE COLLECTED QUALITY CONTROL REQUIREMENTS OF THE PROJECT

More information

CLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.

CLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method. CLEANING Application Recommendations Application/ Concerns Laboratory Reproducible results, no interfering residues, extending equipment life. Keep laboratory accreditation. Laboratory safety. Articles

More information

Amerimade RCA Wet Bench SOP Page 1 of 13 Rev /22/2014

Amerimade RCA Wet Bench SOP Page 1 of 13 Rev /22/2014 Amerimade RCA Wet Bench SOP Page 1 of 13 Bench Features: Amerimade RCA Wet Bench SOP Tanks 1, 2 and 4 are dedicated to RCA Process (HF, SC1, SC2) batch/bulk cleans. All SC1/SC2 use of the bench will incur

More information

Procedures for Preparing and Receiving PUF Canisters and Filters

Procedures for Preparing and Receiving PUF Canisters and Filters QSM Approval: Procedures for Preparing and Receiving PUF Canisters and 1. Introduction This Standard Operating Procedure provides instructions for preparing PUF canisters and filters for shipment to field

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of Tuttnauer Table-Top Autoclave PC-POD-CA-006-v03 Revision History Version Reason for Revision Date 01 New POD 13-Aug-13 02 POD Section 3.1.3 and 3.2 revised

More information

Sanitation Plan Workbook

Sanitation Plan Workbook Sanitation Plan Workbook Contents Overview of this Workbook 1 Part 1: Cleaning and Sanitizing Requirements 2 Part 2: Cleaning and Sanitizing Agents Used in the Establishment 3 Part 3: Identification of

More information

Washroom care programs

Washroom care programs Washroom care programs Table of contents The basics..1 Combining substances...2 Cleaners classification... 6 All day maintenance..12 Daily maintenance......13 Periodic maintenance.....23 Emergency maintenance...

More information

Polypro Acid Wet Bench UCLA Nanolab Yellow Room. Primary contacts: Max Ho, Wilson Lin. PREPARED BY: Steve Franz DATE Rev 2/01/12

Polypro Acid Wet Bench UCLA Nanolab Yellow Room. Primary contacts: Max Ho, Wilson Lin. PREPARED BY: Steve Franz DATE Rev 2/01/12 Polypro Acid Wet Bench UCLA Nanolab Yellow Room Primary contacts: Max Ho, Wilson Lin PREPARED BY: Steve Franz DATE Rev 2/01/12 1 PolyPro Acid Wet Bench 1.0 SCOPE This document establishes the procedures

More information

AUC Cell Washer. User Manual

AUC Cell Washer. User Manual AUC Cell Washer User Manual WARRANTY Spin Analytical Inc., warrants this product to be defect free in both material and workmanship for 90 days from the date of shipment. Labor services are guaranteed

More information

Cleaning Procedures in ICP-MS Laboratories

Cleaning Procedures in ICP-MS Laboratories Cleaning Procedures in ICP-MS Laboratories QSM Approval: 1. INTRODUCTION and SCOPE 1.1. This Standard Operating Procedure provides instructions for cleaning of the regular labware, microwave digestion

More information

BEFORE FIRST USE: TABLE OF CONTENTS

BEFORE FIRST USE: TABLE OF CONTENTS Chill Out Ice Maker BEFORE FIRST USE: To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright

More information

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use Electric Kettle Model MJ-EK5AEU (UK) Household Use User s Manual Thank you for your purchase. Please read this User s Manual before using this product. Retain this User s Manual for future reference. Contents

More information

Bravo Display Warning Messages

Bravo Display Warning Messages Bravo Display Warning Messages The sterilizer periodically reminds the user about recommended routine maintenance operations that must be carried out in order to ensure the proper operation of the device.

More information

General Acids/Bases Bench Right and Left SOP

General Acids/Bases Bench Right and Left SOP General Acids/Bases Bench Right and Left SOP Rev. 5.0 6/2/2016 Page 1 of 6 Bench Features: General Acids/Bases Bench Right and Left SOP The bench consists of 2 independent sides so that 2 users may use

More information

Cleaning & Care. Washing Breast Pump Parts

Cleaning & Care. Washing Breast Pump Parts Cleaning & Care Cleaning & Care Note: These guidelines are for use with a healthy, full-term baby and assume that you have access to potable water. If your baby is premature or has health challenges your

More information

BOUMATIC ROBOT AND THE LELY SAMPLE

BOUMATIC ROBOT AND THE LELY SAMPLE BOUMATIC ROBOT AND THE LELY SAMPLE Boumatic Robot Sampler Page 1 Boumatic Sampling Steps 2 Double-Click Box id 1 Click Service to pause robot 3 Click Shut to open the sample valve. Hook up milk line in

More information

Uridan. Product Information. Uridan Waterless Urinals. Technical Details On Reverse Of Page

Uridan. Product Information. Uridan Waterless Urinals. Technical Details On Reverse Of Page Product Code: Product Info: Uridan Uridan Waterless Urinals Technical Details On Reverse Of Page Benefits Technical Information: Uridan is Australia s leading brand of waterless urinal, widely acclaimed

More information

Application Data Sheet

Application Data Sheet Application Data Sheet Chemical Cleaning after Thinning, Backside Grinding, Lapping, or Polishing of Silicon or Gallium Nitride Substrates Wafer cleaning after thinning, backside grinding, polishing, or

More information

PREPARED BY: Jeff Geraci, Environmental Scientist I. REVISED BY: Kristina Davis, Environmental Scientist III

PREPARED BY: Jeff Geraci, Environmental Scientist I. REVISED BY: Kristina Davis, Environmental Scientist III DOCUMENT TYPE: TITLE: Standard Operating Procedure Redi-Flo Performance Pumps PREPARED BY: Jeff Geraci, Environmental Scientist I REVISED BY: Kristina Davis, Environmental Scientist III REVIEWED BY: Jan

More information

Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy

Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy Effective September 2006 Review September 2009 Due to concerns regarding the microbiological

More information

INSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU

INSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU INSTRUCTION MANUAL Balboa 500DZ-Series Operation Guide Initial Start-up Your spa will enter Priming Mode ( ) when it is energized. During Priming Mode, press Jets button(s) repeatedly and be sure all pumps

More information

Sanitation and Postharvest Handling Decision Tree

Sanitation and Postharvest Handling Decision Tree Do you sort, package, wash, or grade produce in a packing house, shed, or other structure? 1 Regardless of where you pack produce, sanitation practices are going to be important to produce safety. Field

More information

Washroom care programs

Washroom care programs Washroom care programs Table of contents The basics..1 Combining substances...2 Cleaners classification... 6 All day maintenance..12 Daily maintenance......13 Periodicmaintenance.....23 i Emergency maintenance...

More information

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Device Reprocessing Checklist Scoring Matrix 1=low 5=high Measure Standard Q1 Q2 Q3 Q4 Point of Use Gross Debris Removed during & after procedure (use of water preferred) 5 Delicate instruments on top of heavy or separate 5 Devices contained & identified as biohazard

More information

THERMO POT MODEL: ETP-D4013(WH)/ ETP-D5013(WH)/ ETP-D6013(WH) Owner s Manual. Please read this manual carefully before operating your set.

THERMO POT MODEL: ETP-D4013(WH)/ ETP-D5013(WH)/ ETP-D6013(WH) Owner s Manual. Please read this manual carefully before operating your set. THERMO POT MODEL: ETP-D4013(WH)/ Owner s Manual ETP-D5013(WH)/ ETP-D6013(WH) Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial

More information

SCIF SOP for BSL 2 samples on Aria3

SCIF SOP for BSL 2 samples on Aria3 Date Last Modified: July 2, 2015 Author: David Gravano SCIF SOP for BSL 2 samples on Aria3 Overview of BSL-2+ Sorting Area and Procedures: This document aims to provide a description of the facility, instrumentation,

More information

THERMO POT MODEL: ETP-C3211(WH) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

THERMO POT MODEL: ETP-C3211(WH) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference. THERMO POT MODEL: ETP-C3211(WH) Owner s Manual Please read this manual carefully before operating your set. 1 Retain it for future reference. Record model number and serial number of the set. See the label

More information

Dianne Harrison, Supervisor QA Lab

Dianne Harrison, Supervisor QA Lab Housekeeping Tasks and Contamination Control in an Animal Facility Dianne Harrison, Supervisor QA Lab Microorganisms Invisible to the naked eye Need a microscope to see Most common we deal with? Bacteria,

More information

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10CLXD, rinse with - Wash off visible dirt (e.g. blood) using F10CLXD CHAIRS - Trigger spray using F10CL and wipe

More information

Standard Operating Procedures (SOPs)

Standard Operating Procedures (SOPs) Standard Operating Procedures (SOPs) for Food Business Operators Table of Contents 1. Employee Illness and Injury SOP... 4 2. Personal Hygiene SOP... 6 3. Hand washing and Glove Use SOP... 8 4. Purchasing

More information

Stainless Steel Cup. Instructions. Lunch Cup MODEL. Replacing and purchasing consumable parts. Before contact customer service.

Stainless Steel Cup. Instructions. Lunch Cup MODEL. Replacing and purchasing consumable parts. Before contact customer service. Replacing and purchasing consumable parts The lid unit, inner lid gasket, valve, clear cup, clear cup outer lid, and clear cup outer lid gasket are consumable parts. (These parts may be damaged as they

More information

5. Drain excess liquid and allow to air dry. KEEP OUT OF REACH OF CHILDREN DANGER

5. Drain excess liquid and allow to air dry. KEEP OUT OF REACH OF CHILDREN DANGER PRECAUTIONARY STATEMENTS : Corrosive. Causes irreversible eye damage. Do not get in eyes, on skin, or on clothing. Harmful if inhaled. Avoid breathing dust. Wear gloves and protective eyewear such as goggles,

More information

THE NEXT GENERATION CARBOY

THE NEXT GENERATION CARBOY EZgrip Carboy VersaCap VersaBarb Spigot Technology Advanced fluid handling systems developed with the end-user in mind. THE NEXT GENERATION CARBOY EZgrip Carboy Foxx Life Sciences EZgrip carboy is an advanced

More information

Ozone System Maintenance Instructions

Ozone System Maintenance Instructions Ozone System Maintenance Instructions Congratulations on your purchase. If you have any questions please call. Regular cleaning of your system's filter and diffuser is important to keep your system operating

More information

Article begins on next page

Article begins on next page Sanitizing Product Contact Surfaces for Fresh Produce Production Rutgers University has made this article freely available. Please share how this access benefits you. Your story matters. [https://rucore.libraries.rutgers.edu/rutgers-lib/53606/story/]

More information

TURBOWASH TM... Pot and Pan Sink

TURBOWASH TM... Pot and Pan Sink TURBOWASH TM... Pot and Pan Sink MODEL TW ML-110644 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 33800 Rev. A (4-98) Installation, Operation, and Care of TurboWash TM Pot and Pan Sink SAVE THESE INSTRUCTIS

More information

T1 SCRUBBER DRYER OPERATOR MANUAL

T1 SCRUBBER DRYER OPERATOR MANUAL T1 SCRUBBER DRYER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk Web:

More information

Use a dry, soft-bristle brush to dust fabric weekly to remove dirt before it becomes embedded.

Use a dry, soft-bristle brush to dust fabric weekly to remove dirt before it becomes embedded. Fabric Vacuum fabric regularly to remove any dust/dirt. Avoid direct sunlight and weather exposure to keep the fabric looking new. Tend to spills as soon as possible with a damp cloth. For tough stains

More information

APPLICATION NOTE NO. 2D Revised October Instructions for Care and Cleaning of Conductivity Cells

APPLICATION NOTE NO. 2D Revised October Instructions for Care and Cleaning of Conductivity Cells Sea-Bird Electronics, Inc. 13431 NE 20 th Street Bellevue, WA 98005 USA Phone: (425) 643-9866 Fax: (425) 643-9954 E-mail: seabird@seabird.com Web: www.seabird.com APPLICATION NOTE NO. 2D Revised October

More information

Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual

Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual Motif Medical 8 The Green Suite #5601 Dover, DE 19901 Phone: (844) 7-8390 Email: info@motifmedical.com Web:

More information

4/8/2014 GOAL PATIENT EQUIPMENT

4/8/2014 GOAL PATIENT EQUIPMENT Module G APPLICATION OF CLEANING, DISINFECTION AND STERILIZATION PRINCIPLES TO PATIENT CARE EQUIPMENT IN OUTPATIENT HEALTHCARE SETTINGS GOAL Understand how to apply the principles of disinfection and sterilization

More information

Jennings Street School

Jennings Street School Infection Prevention and Control and Protocols Rationale Following standard infection control precautions can minimise the risk of norovirus outbreaks caused by person-to-person transmission in any institution

More information

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE THEATRE AND STERILE PROCEDURES WALLS/TILES - Wash all surfaces from top to bottom using F10SCXD, rinse with - Wash off visible dirt (e.g. blood) using F10SCXD CHAIRS - Trigger spray using F10SC and wipe

More information

Layout and Design by T. Palimenio, Picture credit: Freepik. Cleaning Manual

Layout and Design by T. Palimenio, Picture credit: Freepik. Cleaning Manual Layout and Design by T. Palimenio, Picture credit: Freepik Cleaning Manual Solution Recipes Vinegar/Water Solution 4 cups Water 1 cup Vinegar Vinegar/Soap Solution 1 cup Dish Soap 1 cup Vinegar Vinegar/Water

More information

All products are colour coded for easy identification

All products are colour coded for easy identification DAIRY INDUSTRY All products are colour coded for easy identification APPLICATION PRODUCT TEMP STRENGTH TIME CIP Water Rinse Water Cold - 5 8 Min (Pipelines) Cleaning Cycle Chlor-NF Cold 1:200-1:50 5 8

More information

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information Health Information U S E R G U I D E Home Respiratory Equipment Cleaning Guide This document is intended for Patients and Families for use at home The goal of the cleaning guide is to properly handle,

More information

Requests for Daily Care and Maintenance

Requests for Daily Care and Maintenance Inkjet printer SIJ-320UV Requests for Daily Care and Maintenance This machine is a precision machine equipped with extremely fine mechanisms. Especially, the nozzle surface of the heads from which the

More information

Safety Lab Goggles are required! Apron is optional!

Safety Lab Goggles are required! Apron is optional! Goggles are required! Apron is optional! Station 1: What would acid do to your eye? Materials: 6M hydrochloric acid, dropper, two petri dishes, egg whites. Procedure: 1. Separate the egg white from the

More information

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation Owner s Guide Installation & Operation Fryer HFR Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002137 REV 1 IMPORTANT

More information

STUDENT SAFETY RULES

STUDENT SAFETY RULES STUDENT SAFETY RULES Purpose Science is a hands-on laboratory class. You will be doing many laboratory activities that require the use of hazardous chemicals. Safety in the science classroom is the #1

More information

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES FIRE RADIATION SPILL PERSONAL INJURY CHEMICAL SPILL BIOLOGICAL SPILL Exterior Laboratory Hallway Sign EMERGENCY RESPONSE GUIDE Research and Graduate Studies Manager Laboratory Safety 330-672-4996 tom@rags.kent.edu

More information

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS CAUTION: The following instructions are for all Sklar Coated stainless steel instruments. Read instructions prior to use. Improper

More information

TRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007

TRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007 TRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT 311.005 FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007 These procedures are written to prevent repeated exposure

More information

CORRECT ENDOSCOPE REPROCESSING

CORRECT ENDOSCOPE REPROCESSING CORRECT ENDOSCOPE REPROCESSING Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham HIRL Birmingham 1 Inadequate decontamination procedures and

More information

Recyclables and How to Prepare Them

Recyclables and How to Prepare Them Recyclables and How to Prepare Them Below is an overview of the materials that may be recycled. CARDBOARD Standard Boxes, Pizza Boxes, Food Boxes, Packaging These items may be recycled as long as they

More information

Haz Waste Management

Haz Waste Management Northern California Nanotechnology Center Haz Waste Management Process: Once finished with a hazardous chemical, you will need to dispose of it by aspiration, decanting or bottling. Aspirate whenever possible!

More information

CQUBE EVO OPERATION MANUAL EVO_OM_VKI_EN. Part No.: _06

CQUBE EVO OPERATION MANUAL EVO_OM_VKI_EN. Part No.: _06 EVO_OM_VKI_EN Part No.: 1764212_06 CQUBE EVO OPERATION MANUAL CONTENTS GENERAL INFORMATION...3 Introduction... 3 Warnings... 3 Precautions... 4 Intended use... 4 Hazard intensity levels... 4 Facts & weight...

More information

Arabidopsis Growing Protocol-A General Guide Xiyan Li *

Arabidopsis Growing Protocol-A General Guide Xiyan Li * Arabidopsis Growing Protocol-A General Guide Xiyan Li * Department of Genetics, Stanford University, Stanford, USA *For correspondence: lixiyan@stanford.edu [Abstract] Arabidopsis as the model organism

More information

ChBE Safety Training. July Emily Edwards Lab Coordinator Chemical & Biological Engineering Tufts University 4 Colby St., Room

ChBE Safety Training. July Emily Edwards Lab Coordinator Chemical & Biological Engineering Tufts University 4 Colby St., Room ChBE Safety Training July 2016 Emily Edwards Lab Coordinator Chemical & Biological Engineering Tufts University 4 Colby St., Room 151 617-627-2172 Required Training Chemical Safety Choose 1 of 3 Options

More information

2015 Myco Industries, Inc Fax:

2015 Myco Industries, Inc Fax: Endoscope Cleaning and Handling It is highly important that you manually clean the endoscope immediately after it is removed from the patient, BEFORE it is automated or manually disinfected. Cleaning your

More information

All purpose Cleaner I. All-purpose Cleaner II. Drain Cleaner. 1 quart of warm water. clear water. 1 Tbsp. ammonia* 4 Tbsp.

All purpose Cleaner I. All-purpose Cleaner II. Drain Cleaner. 1 quart of warm water. clear water. 1 Tbsp. ammonia* 4 Tbsp. All purpose Cleaner I 4 Tbsp. baking soda 1 quart of warm water Dissolve baking soda in warm water. Apply with a sponge. Rinse with clear water. All-purpose Cleaner II 1 Tbsp. ammonia* 1 Tbsp. liquid detergent

More information

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V R3 Carpet Cleaner English Operator Manual Model 9004199-230V R For the latest Parts manuals and other language Operator manuals, visit: www.tennantco.com/manuals 9003707 Rev. 01 (07-2016) *9003707* OPERATION

More information

Commit 2 Clean TM/MC. Restroom Care

Commit 2 Clean TM/MC. Restroom Care Commit 2 Clean TM/MC Restroom Care Commit 2 Clean TM/MC Restroom Care Program Table of Contents Restroom Cleaning Procedures... 2-3 Process... 4-6 Daily Cleaning Inside the Restroom... 7-11 After Cleaning...

More information

Ultrasonic Cool Mist Humidifier

Ultrasonic Cool Mist Humidifier Model No.: LV400CH Ultrasonic Cool Mist Humidifier Questions or Concerns? Please contact us Mon-Fri 9:00AM-5:00PM PST at (888) 726-8520 or email support@levoit.com Thank you. Thank you for purchasing

More information

Harvey Chemiclave 5000 Owner And Operator Guide

Harvey Chemiclave 5000 Owner And Operator Guide Is Happy To Present You With This Free Copy Of The Harvey Chemiclave 5000 Owner And Operator Guide Be sure to look to us when it is time to order parts and supplies for your Chemiclave Please Note: Even

More information

PERFORM Operating Document. General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite

PERFORM Operating Document. General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite PERFORM Operating Document General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite PC-POD-NS-007-v03 Revision History Version Reason for Revision Date 03 Name change in Authorization

More information

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 CARBON SPOT 30 EXTRACTOR OPERATOR'S MANUAL IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 Diamond Products www.diamondproductsus.com Printed in the U.S.A.

More information

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000 SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000 TM INSTALLATION AND OWNER S MANUAL C O N T E N T S I. Introduction II. Product Dimensions III. Installation IV. Operation in Emergency Situation V. Periodic

More information

FOOD PREMISES INSPECTION REPORT for Non-Compliant Critical / Non-Critical Items. Sushi Island 210 Water Street, St. John's, NL.

FOOD PREMISES INSPECTION REPORT for Non-Compliant Critical / Non-Critical Items. Sushi Island 210 Water Street, St. John's, NL. / Items For additional information on the process, please see: Food - Annual Mar 21, 2018 601 - Food contact surfaces properly constructed or located, acceptable material Do not use cardboard as a surface

More information

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Specifications / Parts & Contents...

More information

VENDING PROVEN HYGIENE & CLEANING FOR WATER COOLERS. Performance Focus. Recommended Products

VENDING PROVEN HYGIENE & CLEANING FOR WATER COOLERS. Performance Focus. Recommended Products PROVEN HYGIENE & CLEANING FOR WATER COOLERS A powerfully effective and user friendly range of products widely used by machine manufacturers, distributors and vending operators to professionally clean all

More information

60+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS

60+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS 0+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS Routine maintenance is the best way to get the most out of your appliances. You probably know you should clean the lint filter every time you use the dryer and

More information

Hot Chocolate Dispenser

Hot Chocolate Dispenser Hot Chocolate Dispenser Instruction manual Model: CN219-A AU Telephone Helpline: 1300225960 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation

More information

Cleaning and Sanitation Procedures Module Deli

Cleaning and Sanitation Procedures Module Deli Deli Triple Sink System (Clean, Rinse, Sanitize) A. Preparation 1) Wash your hands with anti-microbial soap before and after cleaning and whenever hands are dirty. 2) Dawn appropriate PPE s 3) Place safety

More information

R I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008

R I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008 R I T Title: Manual Processing Bench #2 Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Manual Processing Bench #2 for wet cleaning

More information

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information IM0040A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...

More information

phd Countertop UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

phd Countertop UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized Owner s Manual UltraWater phd Countertop Delicious Great Tasting Antioxidant Alkaline Energized Warning: Incorrect installation and/or operation could void your valuable warranty. Please protect your investment!

More information

PDMS Casting Station Supplies

PDMS Casting Station Supplies PDMS Casting Station Supplies These are provided by the CNF. Please do not use more than you need. Please do not take extra supplies from the lab. Log onto CORAL each time that you use PDMS and the PDMS

More information

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123 Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123 Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.com

More information

HOME DIFFUSER OPERATION MANUAL. Languages. English 2 Español 8 Chinese 14

HOME DIFFUSER OPERATION MANUAL. Languages. English 2 Español 8 Chinese 14 HOME DIFFUSER OPERATION MANUAL Languages English 2 Español 8 Chinese 14 Overview Mannatech s Serenity Home Diffuser functions as a humidifier, atomizer and aroma diffuser in one simple-to-use product.

More information

Cleaning the internal optics surfaces

Cleaning the internal optics surfaces Cleaning the internal optics surfaces The face of the fiber-optic assembly and the lens are directly exposed to sample fluids inside the analyzer s flow cell. Automatic rinse cycles use high-pressure rinse

More information

REFUSE DISPOSAL INFORMATIONS County of Neumarkt (Landkreis Neumarkt i.d.opf.)

REFUSE DISPOSAL INFORMATIONS County of Neumarkt (Landkreis Neumarkt i.d.opf.) ABFALLWIRTSCHAFT LANDKREIS NEUMARKT I.D.OPF REFUSE DISPOSAL INFORMATIONS County of Neumarkt (Landkreis Neumarkt i.d.opf.) THE PROBLEM The mountain of waste is still growing. Environmental pollution and

More information

SteroklorPlus. Cleaner Sanitizer 3IN1Disinfectant KEEP OUT OF REACH OF CHILDREN DANGER. Mold & Mildew Killer and Stain Remover

SteroklorPlus. Cleaner Sanitizer 3IN1Disinfectant KEEP OUT OF REACH OF CHILDREN DANGER. Mold & Mildew Killer and Stain Remover PRECAUTIONARY STATEMENTS : Corrosive. Causes irreversible eye damage. Do not get in eyes, on skin, or on clothing. Harmful if inhaled. Avoid breathing dust. Wear gloves and protective eyewear such as goggles,

More information

WARNING: Product view. Cleaning fluid. Carry Handle. Power Button Formula & Clean Water Tank. Dirty Water Tank. Power Cord. Quick Release Cord Wrap

WARNING: Product view. Cleaning fluid. Carry Handle. Power Button Formula & Clean Water Tank. Dirty Water Tank. Power Cord. Quick Release Cord Wrap Product view Carry Handle Power Button Formula & Clean Water Tank Dirty Water Tank Power Cord Quick Release Cord Wrap Flex Hose To reduce the risk of fire and electric shock due to internal component damage,

More information

TOASTER OVEN INSTRUCTION MANUAL. Model: MCSTO6B. 6 Slice

TOASTER OVEN INSTRUCTION MANUAL. Model: MCSTO6B. 6 Slice TOASTER OVEN 6 Slice INSTRUCTION MANUAL Model: MCSTO6B THANK YOU FOR PURCHASING A MAGIC CHEF PRODUCT. PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE PRODUCT. CONTENTS SAFETY INSTRUCTIONS.... 3

More information

Special Precautions Isolation Plan Environmental Services

Special Precautions Isolation Plan Environmental Services Special Precautions Isolation Plan Environmental Services When page is received that suspect Ebola patient has arrived in ED: If the patient is not going to be admitted: Once patient is transferred to

More information

solargrow Instructions solargrow Phone: Never too much and never too little

solargrow Instructions solargrow     Phone: Never too much and never too little solargrow 3 Any excess drains through the pebbles back into the reservoir 2 Water & nutrients pumped from the reservoir to feed the plants Instructions 1 Solar panel triggers the pump If you require any

More information

eware Handling & Cleaning Procedures

eware Handling & Cleaning Procedures Procedures Best practice in ware washing, equipment and hard surfaces Why am I doing this program? An important part of your job is to enhance the safety and satisfaction of your customers and co-workers.

More information

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information IM0036A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...

More information

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly. TABLE OF CONTENTS Machine Components Safety Precautions Machine Set Up Machine Operation Machine Maintenance & Storage Troubleshooting Technical Specifications Parts Lists Wiring Diagram 1 2 3 3-4 5 6

More information

! It is the responsibility of every team

! It is the responsibility of every team FOOD SAFETY BASICS! It is the responsibility of every team member to serve fresh, wholesome food in a safe and sanitary environment. TYPES OF FOOD SAFETY HAZARDS BIOLOGICAL Bacteria, viruses, parasites

More information

How to care for your water storage tank

How to care for your water storage tank 19/05/2016 How to care for your water storage tank City of Ottawa Residents >» Water and environment >» Drinking water >» Drinking Water Quality >» How to care for your water storage tank How to care for

More information

until filters are dry. Once dry, place the filters shiny side up in petrislides. The petrislide do NOT need to be acid washed.

until filters are dry. Once dry, place the filters shiny side up in petrislides. The petrislide do NOT need to be acid washed. Bottle Washing LDPE bottles must be acid washed prior to use in trace element analyses. The process should take two weeks. Rinse bottles three times with house DI water. One week in 3M HCl (ACS Plus) bath.

More information

Installation & Operating Instructions

Installation & Operating Instructions PREMIUM Installation & Operating Instructions AQP-20SIL Signature Filtered Water Cooler Premium Selection Congratulations on your purchase of a Aquaport Signature Filtered Water Cooler This unit is easy

More information

Growler: Best Practices and New Technologies. Charles Kyle Sierra Nevada Brewing Company

Growler: Best Practices and New Technologies. Charles Kyle Sierra Nevada Brewing Company Growler: Best Practices and New Technologies Charles Kyle Sierra Nevada Brewing Company Growlers: Best Practices for Retailers, Brewers and Consumers Today s Topics: Container Type and Safety The Growing

More information

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER Operators Manual Release Date: June 10, 2013 Publication Number: 741200028OPR Revision Date: May 9, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com

More information

IMPORTANT Read this manual thoroughly before using the appliance. This will ensure optimum results and maximum safety.

IMPORTANT Read this manual thoroughly before using the appliance. This will ensure optimum results and maximum safety. GB IMPORTANT Read this manual thoroughly before using the appliance. This will ensure optimum results and maximum safety. Save these instructions for future reference. IMPORTANT SAFEGUARDS Read the following

More information